The .cimtbl format and the cimtables package¶
This is the design of record for .cimtbl and for the cimtables package that implements it. It describes the
code as built. It replaces CIM-Builder's cimbuilder/development/CIMTBL_DESIGN.md, which was written before the
implementation and before cimtables was split out of CIM-Builder; that file's git history is the record of how
the design got here. The changes are summarized under Changes from the original design.
Goals¶
In priority order: auditability, understandability, ease of use for humans and LLMs.
A .cimtbl file is to CIM what a .dss file is to OpenDSS, except that its vocabulary is the CIM profile.
Column headers are literally CIM attribute and association names, units are on the column header, and each row is
one CIM object. There is no native-to-CIM mapping to maintain, and a model can be read, diffed and hand-edited as
text.
Where it sits¶
cimprofiles → cim-graph → cimtables → cimbuilder
(CIM classes, (GraphModel, (.cimtbl (ObjectBuilders, feeder/
CIMUnit) mRID index, parse/bind, substation assembly)
model scope) documents)
cimtables must never import cimbuilder. Its consumers:
- CIM-Builder:
ObjectBuilder.from_tabledelegates tobind_row, and builders write throughgraph_write. - CIMHub importers: they build
.cimtblartifacts withdocument.pyand load them withload_model. The behaviours they depend on are listed in CIMHub'scimhub_core/src/cimhub_core/development/CIMTABLES_REQUESTS.md("Please keep these stable"). - CIMTBL-Models (
PNNL-CIM-Tools/CIMTBL-Models): git-tracked.cimtblgrid models.
Pipeline¶
.cimtbl text ──parser──▶ RawRecord ──validate──▶ <Class>Row ──bind_row──▶ live cim-graph object
(fixed (cells still (typed, checked (graph_write is the
grammar) text) against the only thing that
profile) mutates the graph)
| Module | Role |
|---|---|
grammar.lark, parser.py |
The fixed grammar; text → RawRecords plus a Header of settings; resolves Import. |
records.py |
RawRecord: one row, every cell still str or None, plus units and source file/line. ImportRecord: an Import as parse_text returns it, before parse_file splices the file in. |
validate.py |
Reflects on the CIM profile to build a <Class>Row dataclass; coerces cells; raises before any graph change. |
synthetic.py |
The only non-reflective vocabulary: the DSL's connectivity and phase columns. |
binder.py |
bind_row: one validated row → one live object, classifying every field from the profile alone. |
connectivity.py |
Terminals, ConnectivityNodes/TopologicalNodes, PhaseCodes and per-phase children. |
graph_write.py |
set_attr, set_assc, add_to_graph, resolve: the only functions that mutate objects or the network. |
impedance.py |
The base for pu/percent impedances. |
units.py |
Qty(value, unit, base), the carrier for a (unit) column. |
document.py |
The parser's inverse: a Document of cell text → deterministic .cimtbl text. |
writer.py |
to_documents: a cim-graph model → Documents that load back into an equal model. |
Load-bearing decisions¶
| Decision | Choice | Why |
|---|---|---|
| Grammar scope | Fixed and profile-agnostic: settings, Import, Object, Table, (unit) suffixes, cells, comments. It knows no CIM class names. |
It never changes when the profile does. Never add CIM-specific rules to it. |
| Validation | Reflection on the live profile module: no LinkML, no curated schema. Any class in the profile is legal. | There's no second schema to drift from the profile. |
| Fail before mutating | A row is validated into a typed <Class>Row before anything touches the graph; errors carry file:line. |
A bad file is rejected with a line number, not half-built. |
| One generic binder | bind_row classifies every field from the profile. There is no per-class dispatch table. |
New classes and new profiles work with no code. |
| One mutation point | Only graph_write calls setattr or network.add_to_graph. |
Unit binding, reverse associations and mRID indexing can't be forgotten at a call site. |
| Identity | Rows are keyed and referenced by mRID, unique within the model (any class). The UUID is seeded from the mRID under the file's model scope. |
Renaming (name) never changes a UUID; references are unambiguous. |
| A model is a function of its text | Everything that affects the result is in the file: profile, model scope, BasePower. |
No hidden dependence on env vars or library defaults. |
| Value + unit | Every unit-bearing column carries its own Qty; pu/percent are converted once, in graph_write. |
No hand-scaled %Z → ohm; r, x and bch each keep their own unit. |
The format¶
Statements¶
Profile = cim18v17
Authority = https://example.com/models
Model = ieee13
Import wire_infos.cimtbl
Object BasePower: mRID=sbase, basePower (MVA)=100
Table ACLineSegment: mRID, node1, node2, phases, length (ft), PerLengthImpedance, BaseVoltage, EquipmentContainer=fdr
650632, RG60, 362, ABCN, 2000, mtx601, base_4160
632645, 632, 645, BC, 500, mtx603, base_4160
- Settings:
Profile =(a profile short name such ascim18v17),Authority =andModel =(the model scope UUIDs are seeded under). Each may be declared at most once per file and Import chain. See Settings. Import <file>.cimtbl: textual composition. The imported file's records are spliced in at that point. The path is relative to the importing file.Object <Class>: k=v, ...: one object.Table <Class>: col, col, ...then one indented row per object.#starts a comment, either on its own line or after content. Blank and comment-only lines are ignored everywhere.
A keyword is only lexed as one where its statement's shape follows (Table X:, Profile =, Import x), so a
row cell such as Object_1, Profiles or Tablet is just a value.
Object vs Table is about cardinality, not raggedness. Use Object for a singleton (EnergySource,
BasePower) and Table for many objects, even ragged ones, since blank cells are legal. The two forms build
exactly the same objects.
Cells¶
- A blank cell is unset. So is a cell that is only whitespace. Unquoted cells are trimmed.
- A quoted cell is CSV-style:
"..."takes,#()literally,""is one embedded quote, and a quoted""is the empty string, not unset. Source names are kept verbatim, never sanitized:"#2_ACSR_6/1","DEFAULT (DC)". - A cell can't hold a newline.
- Booleans are
true/false/1/0(any case). Enum cells are the enum's value (D,Y,discharging).
Table header defaults¶
A header column may carry a default, EquipmentContainer=fdr. A row's cells fill the columns without defaults,
in header order. Any extra trailing cells then override the defaulted columns, also in header order:
Table EnergyConsumer: mRID, node, p (kW), q (kVAr), BaseVoltage, EquipmentContainer=fdr
load_671, 671, 1155, 660, base_4160
load_sub, SourceBus, 2000, 1000, base_115, sub # overrides EquipmentContainer
Units¶
The unit is on the column header and applies to every cell in it: basePower (MVA), r (ohm/mile),
length (ft). A unit-bearing column with no (unit) is read in SI base units (W, V, ohm, S, m).
(pu) and (percent) on an impedance or admittance column are relative. Their base is described under
Relative impedances. (pu system) / (percent system) put that column on the system base
even on a rated class. system is the only base word, and only pu/percent take it.
Row key and identity¶
An IdentifiedObject row must have an mRID. The object is built from it (cim_cls(mRID=...)), so its UUID is
seeded from the mRID and the model scope; renaming it (name) keeps the UUID. mRIDs are unique within the
model, not per class, and reusing one in any class raises. Translators prefix them to keep them distinct (bus
671 vs load ld_671). That convention is the translator's, not enforced beyond uniqueness.
An Object/Table row whose mRID is already bound in the same class restates it: the same facts again
leave the model unchanged. Each feeder file can declare the BaseVoltages it uses, a boundary file can declare a
node the equipment that first touched it already created, and a file imported from two branches binds twice.
Every cell the row sets must equal what is bound (CIMUnits within 1e-9 relative, in any unit; pu/percent read
back on the same base; a list-valued reference must contain the target; node/bus columns must name the nodes of
the bound Terminals). Blank cells say nothing. A different class, a different value, or a value the object
doesn't have yet raises, so a repeat never changes the model and load order can't either. Adding a value is
Update's job. The phases and wkt shorthand can't be restated, so write them only where the object is
defined.
A CIM 18 Identity-only class has no mRID (e.g. PhaseImpedanceData). It takes an optional identifier
column instead, which seeds the UUID the same way. Without one the UUID is random. Identity-only objects aren't
indexed, because nothing references them. A row whose identifier seeds a UUID already in the model restates
that object under the same rules as an mRID, so a line configuration's PhaseImpedanceData can travel with its
PerLengthPhaseImpedance into every file that declares it. A row without an identifier is always new.
name is optional, non-unique data like any other attribute.
References¶
A reference column is named by the association (BaseVoltage, PerLengthImpedance, PowerTransformer) and its
cell holds the target's mRID. The association's range is often an abstract class (PerLengthImpedance,
EquipmentContainer): any subclass matches, and an mRID that belongs to an unrelated class raises.
Targets must be declared before the rows that reference them. References are resolved as each row is bound.
Where the profile serializes only one side of an association (e.g. cim18v17's
TransformerWinding.FromTransformerLug is serialize=False), write it from the other side.
Same class, several header shapes¶
One class may appear in several tables with different columns. For example, an ACLineSegment can be given
by bus1, bus2, r (pu), x (pu), bch (pu) or by node1, node2, phases, length, PerLengthImpedance. Which fields
are present is what selects the representation; rows carry no shape flag.
Connectivity columns¶
These are the only column names that aren't CIM attributes (synthetic.py). They are exact names only: a
prefix rule would capture real attributes such as TopologicalNode.busName.
| Column | Terminal goes to | Terminal sequenceNumber |
|---|---|---|
node, node1 |
ConnectivityNode | 1 |
node2 |
ConnectivityNode | 2 |
bus, bus1 |
TopologicalNode | 1 |
bus2 |
TopologicalNode | 2 |
- The sequence number comes from the column name, not header order.
node1andbus1together put one Terminal on both a ConnectivityNode and a TopologicalNode, as PSS/E RAW's node-breaker substation data does. These are two objects, and mRIDs are unique within the model, so the two cells need different values: a source with one ID per node has to make up the second key (e.g.tn_<ID>).- A node or bus that was never declared is created on first use, with the cell value as its mRID.
- Terminals are named
<mRID>_T<n>. - A
TransformerEndrow'snode/busputs its Terminal on the end's transformer, withsequenceNumber = endNumber, and pointsend.Terminalat it. The transformer is the end's one ConductingEquipment reference, found by type hint:PowerTransformerEnd.PowerTransformer,AutoTransformerEnd.AutoTransformer. That reference andendNumbermust be set. - Containers. The equipment's
EquipmentContaineris the row's own column, else the containerbind_rowwas given, elsenetwork.container. Every node touched gets that container as itsConnectivityNodeContainerunless it already has one. A TransformerEnd's nodes take its transformer's container.
A real CIM attribute of the same name always wins over a DSL column.
The connectivity columns are shorthand, never the only way. Terminals may be written out as their own rows,
either after their equipment (Table Terminal: mRID, ConductingEquipment, ConnectivityNode, sequenceNumber) or
first, with an Update Table Terminal: mRID, ConductingEquipment once the equipment exists. A consumer that
needs a model's Terminals reads them from the bound model, not from the text: the .cimtbl contract is what
binding makes.
Phases¶
phases lists conductors in order: ABCN, CB, s1s2N. The order is the conductor order, e.g. a phase
impedance matrix's row order.
No phases is balanced three-phase. A blank or absent phases cell makes no <Class>Phase children and
leaves Terminal.phases unset, which CIM defines as ABC ("If the attribute is missing, three phases (ABC) shall
be assumed", Terminal.phases). That is how a balanced device is written, on any class, including one with no
<Class>Phase child class (SeriesCompensator). A consumer that wants every Terminal's phases explicit can fill
the missing ones in after loading. phases=ABC means three separate phases, a per-phase device.
- Every Terminal gets the canonical
PhaseCodeof the set (CB→BC,s1s2N→s12N). - One
<Class>Phasechild is made per token, carrying the normativeSinglePhaseKindand asequenceNumberwhere the class has one. The child class is found by walking the MRO (LinearShuntCompensator→LinearShuntCompensatorPhase,Breaker→SwitchPhase). Children are named<mRID>_<phase>. sequenceNumbersbesidephases(orphaseSide1/phaseSide2) gives the children'ssequenceNumberinstead of 1..n: space-separated, one per child in child order, e.g.phases=ABCN, sequenceNumbers=8 9 10 4. It is for a line on a sharedWireSpacing, whose positions are numbered once for the spacing (the second circuit of a double-circuit span on 8/9/10 with the shared neutral on 4, a triplex secondarys1s2Non 5/6/7); CIMHub-gis places each conductor by itsACLineSegmentPhase.sequenceNumber. A blank cell is 1..n. A count that differs from the children, a repeated number, a number below 1, the column withoutphases, or a child class with nosequenceNumber(cim18v17: onlyACLineSegmentPhase/WireSegmentPhasehave one) raises.- Delta shunts (
phaseConnection=D) get one child per line-to-line branch,Nignored. The child'sphaseis the from-phase (normative CIM: "connected from the indicated phase to the next logical non-neutral phase", A→B→C→A, s1→s2). Where the class has thephasesextension (cim18v17EnergyConsumerPhase), it also gets the branch PhaseCode: branch CA isphase=C, phases=AC. Children are named<mRID>_<BC>. - Switches whose sides differ take
phaseSide1=AB, phaseSide2=ACinstead ofphases. The sides pair by position (A→A, B→C) and each Terminal gets its own side's PhaseCode. On a class whose child has a singlephase, differing sides raise. - A
TransformerEnd's phases go on its Terminal only. AnAutoTransformerEndhas a realphase(a PhaseCode), so it takesphaseinstead ofphases, and its Terminal gets the same PhaseCode; aphasescolumn on it raises. TheVoltageRegulatoritself has no per-phase child class, sophaseson it raises (a delta bank would be the case that needs one). - The shorthand applies only where the class has no real
phasesattribute.Terminal.phasesandEnergyConsumerPhase.phasesare set literally.
Per-phase children may also be written as their own table (EnergyConsumerPhase rows with an EnergyConsumer
reference) for per-phase data.
Matrix impedance is literal¶
Matrix impedance is one PhaseImpedanceData row per matrix element, referencing its
PerLengthPhaseImpedance. Compact rmatrix/xmatrix sugar is deliberately not supported: every element stays
a visible, addressable row, and the format stays purely reflective.
Templates are associations¶
There is no Template column. A reusable template is a real CIM association: ACLineSegment.WireConfiguration
for lines, TransformerTank.TankConfiguration for transformers.
Relative impedances¶
A pu/percent value on an ohm-typed attribute is multiplied by z_base = U²/S; on a siemens-typed one it is
divided by it (one base for both). A PerCent attribute (percentImpedance, pfixedPct, ...) holds the percent
number: unitless or (percent) is stored as written, (pu) as the fraction times 100 (0.02 → 2.0, as GridLAB-D
writes efficiencies), and get_qty reads it back in either; no base applies, and any other unit raises.
The base is chosen by class shape, never by which values happen to be set:
- A rated class uses its own rating: the row's object if its class is rated (
PowerTransformerEnd), else the target of one of its single-valuedFrom*references (TransformerMeshImpedance.FromWinding). A class withbaseU/baseSuses those (TransformerWinding: coil voltage, common tank kVA), otherwiseratedU/ratedS, each side on its own:AutoTransformerEndhasbaseUbut onlyratedS, so it usesbaseU/ratedS(coil voltage, through rating). Both must be set. - Any other class (
ACLineSegment,EnergySource) uses the system base: itsBaseVoltage(ornomUwhere the class has it) and the system base power.
A U or S of 0 or less raises rather than dividing by zero or flipping the sign of every value read on it.
(pu system) always takes step 2, for source data already on SBASE (PSS/E transformer impedances).
The system base power comes from a bound Object BasePower: basePower (MVA)=..., which must be declared before
any row that uses it. A BasePower with no basePower, or a second one that disagrees, raises. The result never
depends on cim-graph's CIMG_SYSTEM_MVA_BASE or its 100 MVA default.
The ratings, BaseVoltage and From* references must be set before the conversion, so bind_row writes
relative values last. The rationale and the open IEC WG13 question are in
.development/PERCENT_IMPEDANCE_BASE.md.
Settings¶
The parser reads the settings but applies none of them; load / load_model do.
- Within an Import chain, a setting is declared at most once per file. An imported file's setting fills one
the importer left unset. One that disagrees with an already-set value raises at the Import line, as does an
Import cycle. A file imported from two branches is not a cycle; its rows bind twice, and the second time
they restate (see Row key and identity), so that file can't use the
phasesorwktshorthand. Profile =names the CIM profile the rows are written against.load_modelwrites it toCIMG_CIM_PROFILEbefore building its model.load/load_textrequire it to be the network's own profile. With noProfile =, the environment'sCIMG_CIM_PROFILEis used; with neither, validation fails. Only short names fit the grammar, so a comma-spec merged profile must come from the environment.Authority =/Model =replace that half of cim-graph's model scope (set_model_scope) before binding, so UUIDs are seeded per model: bus671in IEEE13 and in IEEE123 get different UUIDs.write_xml's model header carries the scope and the XML reader restores it. An undeclared half is left as it is.
Both the profile and the model scope are process-global.
Validation¶
validate(record, profile=None) turns a RawRecord into a <Class>Row or raises CimtblValidationError.
Profile resolution. The active profile (CIMG_CIM_PROFILE, or an explicit profile equal to it) is resolved
through cim-graph's get_cim_profile(), so the module is the same object as network.cim, comma-spec merged
profiles included. An explicit profile that differs from the environment is imported directly, resolved by
cimprofiles.profile_module as cim-graph does, without touching process state.
Reflection. Every dataclass field of the CIM class is a column, except:
- reverse/derived associations (
metadata['serialize'] is False, e.g.Terminals), which are excluded; mRID/identifier, which are the row key.
Each remaining field is classified from its type hint:
- quantity: the hint contains a
CIMUnitsubclass. The cell becomes aQty(value, unit, base). - reference: the hint contains a CIM dataclass. The cell stays an unresolved mRID string.
- scalar: anything else. The cell is coerced to
str/int/float/bool/the enum.
The synthetic columns are added to every row class, unless the class has a real attribute of that name. Row classes are built on demand and cached per (profile, class).
Errors name the file and line: an unknown class, an unknown column (with the closest valid name suggested), a
missing mRID, an mRID on an Identity-only class, a cell that doesn't coerce, a base word on a non-relative
unit.
Binding¶
bind_row(network, row, *, obj=None, container=None) builds the object from the row key (unless a builder passes
obj; an mRID or identifier that is already bound is checked as a restatement instead, see
Row key and identity), then sorts every set field into exactly one bucket, purely from the profile:
| Field | Goes to |
|---|---|
| a connectivity column | connectivity.add_connectivity |
phases / phaseSide1 / phaseSide2 / sequenceNumbers |
connectivity.add_phase_children |
EquipmentContainer |
resolved, then used as the container |
| any other reference | resolved, then set_assc (an unresolved mRID raises) |
a relative Qty |
set_attr, deferred to the end |
everything else, name included |
set_attr |
The order is fixed: scalars, then references (a TransformerEnd's Terminal needs its PowerTransformer), then
connectivity and phases, then relative values (their base needs the ratings and references), then
add_to_graph.
A ValueError/TypeError binding a row read from a file is re-raised as CimtblBindError, prefixed with the
row's file:line. It subclasses both, so existing except clauses still catch it, and it keeps the original as
__cause__.
The graph-write core¶
graph_write holds the only functions that mutate a cim-graph object or the network. Every other module, and
CIM-Builder's builders, route through it.
set_attr(obj, part, attr, value, *, system_base=None)enforces the field's declared type, as cim-graph's owncreate_valuedoes. A bool field takes only abool(never the string'false'), and a bool is never a number. A number on a CIMUnit field is read as SI base. A CIMUnit is converted into the field's own (per-profile) CIMUnit class, and pint raises on a dimension mismatch. AQtyis converted from its unit; a relative one goes through the impedance base. Text parsing is not its job: that'svalidate.set_assc(obj, part, assc, target)writes both sides of an association, finding the reverse from the field'smetadata['inverse'], so the graph is never one-sided. List sides append once (dedup by identity), scalar sides overwrite.set_attron an association, orset_asscon a plain attribute, raises.add_to_graph(network, obj)adds the object and indexes its mRID; cim-graph raises on a reused mRID. ABasePoweralso setsnetwork.base_power, under the rules above.resolve(network, cls, mRID)is cim-graph'sfind_by_mRIDplus anisinstancecheck.set_assc_from_mridisresolve+set_asscfor builders.
The part argument is a profile module checked by class name only: attr must be a field of part's
class named type(obj).__name__. A part-scoped module (a profile's connectivity slice) lets a builder's
add_<part> method enforce that it writes only that slice's fields. Passing the merged network.cim is the
documented no-op check used at the reflective call sites (binder, connectivity), where validate has already
decided what a row may carry.
Entry points¶
load(path, network): parse, validate and bind a file onto an existing network. Returns the bound objects in file order.load_text(text, network, source_file='<text>'): the same for a string. AnImportraises, since it needs a file to resolve against.load_model(path, model_cls=None): builds the model too. It appliesProfile =and the model scope, then binds every row into an in-memoryNodeBreakerModel(connection=None) that has no container, sonetwork.containernever leaks into anEquipmentContainerthe file didn't declare. The result:- the file's one
Feeder→ aFeederModelwith it as container (a profile withoutFeeder, such as CGMES, has none); - else its one
Substation→ aNodeBreakerModelwith it as container; - else a
NodeBreakerModelwith no container (e.g. a lone padmount).
An explicit model_cls asserts the shape rather than inferring it from how many containers the file has:
- FeederModel: the file's one Feeder as container; none, or several, raises;
- NodeBreakerModel: one whatever Feeders the file has (a tiered TSO-DSO model holds several), its
container the file's one Substation, else None;
- BusBranchModel (PSS/E RAW, MATPOWER): its container the file's one GeographicalRegion, else None.
- bind_row: for builders that produce rows themselves (ObjectBuilder.from_table).
Errors¶
| Error | Raised for | Location |
|---|---|---|
CimtblParseError (ValueError) |
syntax; a missing Import, an Import cycle, a conflicting Import setting, a duplicated setting | <file>:<line>:<col>:, or <file>:<line>: at the Import. <file> is the file the error is in, imported files included. |
CimtblValidationError (ValueError) |
unknown class/column, missing key, bad cell; a Profile = that isn't the network's |
<file>:<line>: |
CimtblBindError (ValueError, TypeError) |
unresolved reference, mRID reused, missing rating or BasePower, type mismatch, … |
<file>:<line>: |
Writing .cimtbl¶
Documents (document.py)¶
An importer builds a Document of cell text (Table, ObjectStatement, Import; None is blank, '' is
quoted empty, optional comments on documents, tables and rows). Turning typed values into text (repr(float),
true/false, enum names) is the importer's job. format_document gives deterministic text:
- the order is the document comment, the settings, then the statements, with one blank line between each and a trailing newline;
- table rows are indented 4 spaces, and each cell but the last is padded after its comma to the column's widest cell;
- a cell is quoted if it holds any of
,()#", has leading or trailing whitespace, is'', or starts like a statement; a newline raises; - a row comment goes on its own
#lines above the row. ATable(..., footnotes=True)instead lists each distinct row comment once, as# note N:lines above its header (numbered in order of first use), and ends each commented row with# note N. This is for large generated tables whose rows share a few notes. It is off by default, so existing goldens don't change. - a
Table(..., commented_columns=[...])writes columns the profile does not have yet (proposed attributes, e.g. a datasheet column missing from the UML) after its header as# name (unit), ..., and each row'sRow(..., commented=[...])cells after its last cell as# cell, ..., aligned like the rest. The parser ignores them. Once the profile gains the attributes, replacing each#with,makes them real columns, so every row writes every commented cell. A table with defaulted columns or footnotes cannot have them.
write_documents(DocumentSet(master, parts), dir) writes <name>.cimtbl for each document (UTF-8, \n) and
returns the master's path. It writes nothing if a name repeats, an Import is unknown, a part is never imported, or
dir holds a stale .cimtbl. CIMHub diffs this output byte for byte.
The cim-graph → .cimtbl writer (writer.py)¶
to_documents(network, name, *, terminals='folded', units=None, parts=None) turns a model into a
DocumentSet, written with write_documents. It is checked by loading the output back (load_model) and
comparing it with diff_models. Byte-identical text is not a goal: the model doesn't record a file's header
shapes, units or split, so the writer chooses them.
- Rows. One row per object in its class's
Table(anObjectfor a class with one instance), keyed bymRID(an Identity-only object by itsidentifier, written as its UUID). Columns are the key,name, the connectivity and phase columns, then the class's fields in profile order, each only if some row sets it; a blank cell is unset. - Terminals, folded (the default). An equipment's Terminals become its
node/node1/node2andbus/bus1/bus2columns, and its<Class>Phasechildren itsphases(orphaseSide1/phaseSide2) column, plussequenceNumbers(phases in canonical order) where the children aren't numbered 1..n, wherever binding that row makes exactly them: the writer reads a candidate cell off the children and compares them withconnectivity.phase_plan, the same planadd_phase_childrenbuilds from. ATransformerEndtakes its own Terminal asnode(andphases). Folded objects get binding's generated mRIDs (<mRID>_T<n>,<mRID>_<phase>), so their mRIDs and UUIDs change, and references to them follow; their other attributes becomeUpdaterows. An equipment that doesn't fold (three terminals, odd sequence numbers, children binding wouldn't make, a node binding would put in a container) keeps them all explicit. - Terminals, explicit. Every Terminal and phase child is its own row with its own mRID: the lossless form.
- Order. Classes are sorted (Kahn's algorithm, ties by name) over the references only one side can write: a
single-valued side whose inverse is unserialized or a list. Rows are sorted by key. Of an association whose
two single-valued sides are both serialized (
AutoTransformerEnd.RatioTapChangerandRatioTapChanger.TransformerEnd), only the later object writes it. A reference to a row not yet written (a cycle, such as a compensator and the control that names its Terminal) and a list-valued side becomeUpdaterows at the end of the master, when every object exists. An object with a deferred reference defers its pu/percent cells with it, so their base is bound first. - Units.
units={'Class.attr' or 'attr': unit}(or a JSON file of it) fixes a column's unit, matched on the row class or any base (TransformerEnd.r),pu/percentandpu systemincluded, read throughget_qty. Otherwise a quantity column is in SI or a readable multiple (kV, kW, MW, kVA, ohm/km, uS/km, ...): the one that puts the column's median in [1, 1000), else the one with the fewest digits. Quantities are written with the fewest significant digits that read back within 1e-12 (13.2kV, not13.200000000000001); every other number exactly. - Parts.
parts={part: [class names]}writes those classes into<part>.cimtbl, imported by the master at the first class's place. A split in which parts, or a part and a master class, reference each other raises: an Import can't be both before and after another. - Limits. UUIDs are seeded from mRIDs, as for any
.cimtbl, so a CIM XML object whose UUID isn't its mRID's gets a new one, and an object without an mRID is written with its UUID as one. Round trips are exact forload_model, which binds with no container;load(path, network)into a model with a container also defaults one onto rows that have none.
Open questions¶
- Forward references. The original design resolved references in a second pass so files could be in any
order.
bind_rowresolves immediately, and CIMHub depends on bind-time resolution, so changing this is a contract change. - Profiles beyond cim18v17. Binding is reflective, but only cim18v17 is tested in depth. CGMES 2.4 and 3.0
have stubs (
tests/test_cgmes.py): a node-breaker and a bus-branch model load and round-trip through the writer. - The percent-impedance base for windings is an open IEC WG13 question (
.development/PERCENT_IMPEDANCE_BASE.md).
Changes from the original design¶
For readers of CIM-Builder's original CIMTBL_DESIGN.md:
| Original design | Now |
|---|---|
A LinkML schema + gen-python validates rows |
Reflection on the live profile module |
Per-class Builders execute every row (Table ACLineSegment → ACLineSegmentBuilder) |
One generic bind_row; builders are optional and delegate to it |
References by name, a NameIndex per class, names unique within a class |
References by mRID; cim-graph's mRID index; mRIDs unique within the model |
| Second-pass resolution, forward references legal | Declare before use (see Open questions) |
Template column, TransformerAssembly matched on endNumber |
No Template column; real associations (WireConfiguration, TankConfiguration) |
baseKind column, percent → winding / pu → system defaults |
The base is chosen by class shape; (pu system) is the only override |
Terminal sequenceNumber follows column order |
Fixed by the column name |
The parser sets CIMG_CIM_PROFILE; defaults to cimhub_2026 |
The parser applies nothing; load_model sets it, load checks it; no default |
Qty.to_cimunit does the conversion |
graph_write.set_attr + impedance.z_base |
dsl/ and core/ sub-packages of cimbuilder |
The flat cimtables package |
These parts of the original are out of scope here and stay in CIM-Builder's history: the builder API, the VS Code extension, the CIM-Repair / CIM-Asset-Manager strategy and the phased build plan.