Units and impedance bases

Units go on the column header

Table ACLineSegment: mRID, node1, node2, length (ft), r (ohm), x (ohm), BaseVoltage
Object BasePower: mRID=sbase, basePower (MVA)=100

The unit applies to every cell in the column. Any unit the value's CIM type can convert from works: kV, kW, MVAr, ohm/mile, uS, ft. A unit-bearing column written without a unit is read in SI base units (W, V, ohm, S, m).

The model always holds CIM's own SI types, exactly as CIM XML does: length (ft)=2000 is stored as 609.6 m, and p (kW)=1155 as 1,155,000 W. Read a value back in any unit with cim-graph's .to():

line.length.to('ft')     # 2000.0
load.p.to('kW')          # 1155.0

Percent-typed CIM attributes (percentImpedance, pfixedPct) hold the percent number itself: 5, with or without (percent), is stored as 5.

pu and percent impedances

A (pu) or (percent) value on an impedance (ohm) or admittance (siemens) column is converted to ohms or siemens against a base, z_base = U² / S. Which base depends on the class, never on which values a row happens to set:

Class Base
A rated class, such as PowerTransformerEnd Its own rating: ratedU and ratedS.
A class that points at a rated one, such as TransformerMeshImpedance The rating of its From... end.
Anything else, such as ACLineSegment or EnergySource The system base: its BaseVoltage and the model's BasePower.
Object BasePower: mRID=sbase, basePower (MVA)=100
Object BaseVoltage: mRID=bv_4160, nominalVoltage (kV)=4.16
Object PowerTransformer: mRID=xf

Table PowerTransformerEnd: mRID, PowerTransformer, endNumber, ratedU (kV), ratedS (kVA), r (percent), BaseVoltage
    xf_1, xf, 1, 4.16, 500, 1, bv_4160                     # 1% of 4.16² / 0.5 = 0.346 ohm

Object TransformerMeshImpedance: mRID=z_12, FromTransformerEnd=xf_1, x (percent)=5     # on xf_1's rating

The system base

The system base power is the model's BasePower object, never a library default. Declare it before any row that needs it; a system-base value before it is an error, as is a second BasePower that disagrees with the first.

Data already on the system base

Source data that is on the system base even for a rated class, such as PSS/E transformer impedances, uses (pu system) or (percent system):

Table PowerTransformerEnd: mRID, PowerTransformer, endNumber, ratedU (kV), ratedS (kVA), x (pu system), BaseVoltage
    xf_1, xf, 1, 4.16, 500, 0.1, bv_4160                   # 0.1 × 4.16² / 100 = 0.0173 ohm

system is the only base word, and only pu and percent take it.

What a rated class needs

Every value a relative impedance depends on is set before the conversion, wherever it appears in the row: the ratings, the BaseVoltage and the From... reference. If one of them is missing, the row raises rather than guessing:

model.cimtbl:2: PowerTransformerEnd 'xf_1': a pu/percent impedance needs both ratedU and ratedS set