Writing a getter¶
A getter is the one place that knows how CIM holds a concept. An exporter never reads a CIM attribute for a value itself: it calls a getter and shapes the result into the native format.
cim18v17 objects ──getters (units, bases, resolution)──▶ NamedTuples ──spoke mapper──▶ native model ──writer──▶ file
The rules below are the ones in the
export-getters skill,
shown as they appear in real getters. Where a doc and the code disagree, the code wins. The finished getters are listed
in the getter reference. Before you add one, check the code in
getters/, and check that
the capability does not belong upstream (cimtables, cimbuilder, cimgraph, cimprofiles, cim-topology). If it does, file
it in
UPSTREAM_REQUESTS.md
instead of writing a local stand-in (invariant I9).
Spoke sessions do not edit core. A new getter is a request to the core owner; this page is what the core owner (and a reviewer of a spoke's request) checks it against.
Where a getter goes¶
| What | Where |
|---|---|
| A getter for one CIM concept | cimhub_core/src/cimhub_core/getters/<concept>.py, one module per concept (line_impedance.py, tap_changer.py, shunt.py) |
| Helpers every getter shares | getters/__init__.py: describe(obj) and required_qty(obj, attribute, unit, **bases) |
| A formula CIM has no attribute for | cimhub_core/src/cimhub_core/derived/<name>.py, a pure function (Derived values) |
| Its tests | cimhub_core/tests/test_getters_<module>.py |
| Its fixture | a shape in cimhub_core/src/cimhub_core/shapes/, or an inline atom in the test |
| Its docs | a row in the reference table and a section on the page for its group |
A module starts with a docstring that says which CIM paths it reads, and what it deliberately does not read. A reader
should learn from it what a new producer has to write. See the docstrings of
current_limits.py
and
tap_changer.py.
The shape of a getter¶
A getter takes the CIM object and keyword arguments that choose a meaning or a unit. It reads through get_qty, raises
for what it cannot go on without, and returns a NamedTuple. This is the whole of get_switch_state:
import cimprofiles.cim18.cim18v17 as cim
from cimhub_core.getters import describe
STATE_ATTRIBUTE = {"actual": "open", "normal": "normalOpen"}
def get_switch_state(switch: cim.Switch, *, which: str) -> bool:
if which not in STATE_ATTRIBUTE:
raise ValueError(f"which must be one of {sorted(STATE_ATTRIBUTE)}, not {which!r}")
attribute = STATE_ATTRIBUTE[which]
is_open = getattr(switch, attribute)
if is_open is None:
raise ValueError(f"{describe(switch)}: {attribute} is unset")
return is_open
A toy getter written the same way runs against a public shape. It uses required_qty, which is get_qty that raises
ValueError naming the class and mRID when the attribute is unset.
from pathlib import Path
from typing import NamedTuple
import cimprofiles.cim18.cim18v17 as cim
from cimtables import load_model
from cimhub_core.getters import required_qty
from cimhub_core.getters.switch_state import get_switch_state
SHAPES = Path("cimhub_core/src/cimhub_core/shapes")
def by_mrid(network, cls, mrid):
return next(obj for obj in network.graph[cls].values() if obj.mRID == mrid)
class LineLength(NamedTuple):
length: float # the caller's unit
def get_line_length(line: cim.ACLineSegment, unit: str = "m") -> LineLength:
return LineLength(required_qty(line, "length", unit))
lines = load_model(SHAPES / "line_by_impedance.cimtbl")
line = by_mrid(lines, cim.ACLineSegment, "ln_l1")
print(round(get_line_length(line, "ft").length, 6), round(get_line_length(line).length, 3))
# 300.0 91.44
line.length = None
try:
get_line_length(line)
except ValueError as error:
print(error)
# ACLineSegment 'ln_l1': length is unset
switch = by_mrid(load_model(SHAPES / "switch.cimtbl"), cim.LoadBreakSwitch, "sw_s1")
print(get_switch_state(switch, which="actual"))
# True
try:
get_switch_state(switch)
except TypeError as error:
print(error)
# get_switch_state() missing 1 required keyword-only argument: 'which'
The rules¶
| # | Rule | Real code that shows it |
|---|---|---|
| 1 | One getter per CIM concept, returning all of its fields. Callers ignore what they do not need. Never get_line_r_x and get_line_r0_x0. |
get_line_sequence_impedance returns r, x, b, g and the zero-sequence values in one SequenceImpedance |
| 2 | Return a NamedTuple. It unpacks positionally, z.x cannot swap with z.r, and a new field does not break callers. Never a bare tuple or a dict of mixed values. |
TransformerModel, Winding, TapSteps |
| 3 | The caller names the unit; plain floats come out. No CIMUnit leaves a getter. |
get_current_limits(line, "kA"), get_wire_info(wire, "in", "ohm/mi") |
| 4 | All unit and base conversion goes through get_qty. |
every get_qty(..., unit) call in getters/ |
| 5 | Base selection is z_base's, never the getter's. |
get_line_sequence_impedance(..., "pu", base_power=...) |
| 6 | cim18v17 only. No electrical *Info catalog. |
get_line_geometry and get_line_code instead of WireSpacingInfo; TransformerTankConfiguration instead of TransformerTankInfo |
| 7 | No profile-module argument. There is one profile; read classes from the object. | cim is imported once at the top of each module |
| 8 | Format-specific shapes stay in the spoke: GLM "BCN", DSS .1.2.3 bus suffixes, RAW bus numbers, naming policy. Core returns CIM meaning: phases as SinglePhaseKind in conductor order, nodes as objects. |
get_conductor_phases, get_terminal_nodes |
| 9 | Getters are pure. They read and return; they never add objects to the graph or write a computed value back onto CIM. | none writes an attribute |
| 10 | Fail fast. A missing required value raises, naming the class and mRID. No silent default (0.0, 1.0, a 10 m height, 60 Hz). |
required_qty, describe |
Phases come from the equipment (ACLineSegment.ACLineSegmentPhases, Terminal.phases), never from a template's
back-list: WireConfiguration.ACLineSegements[0] can be empty.
get_qty and base selection¶
cimtables.graph_write.get_qty is the read-side mirror of set_attr:
get_qty(source_object, attribute_name, unit, *, base=None, system_base=None, power_base=None) -> float | None
It returns the attribute in unit ('kV', 'ohm/mile', 'MVAr'), or None when it is unset. 'pu' and
'percent' on an ohm- or siemens-typed attribute are set_attr's conversion inverted, through the same
cimtables.impedance.z_base. The getter picks no base; the object's own class does:
| The object is | z_base uses |
|---|---|
a rated class: a TransformerWinding, a PowerTransformerEnd |
its own baseU/baseS (winding) or ratedU/ratedS (end) |
a From* reference, such as a TransformerMeshImpedance |
the From end's |
an unrated class: an ACLineSegment, an EnergySource |
its BaseVoltage and the system base power (network.base_power), passed as system_base= |
A missing rating or BaseVoltage raises. Per-unit on an unrated class without a system_base raises too:
from cimhub_core.getters.line_impedance import ImpedanceSource, get_line_sequence_impedance
line = by_mrid(lines, cim.ACLineSegment, "ln_l2")
z = get_line_sequence_impedance(line, "pu", base_power=lines.base_power, derive=ImpedanceSource.PER_LENGTH_SEQ)
print(round(z.r, 4))
# 0.3073
try:
get_line_sequence_impedance(line, "pu", derive=ImpedanceSource.PER_LENGTH_SEQ)
except ValueError as error:
print(error)
# ACLineSegment 'ln_l2': a pu/percent impedance needs a rated From* reference, or a BaseVoltage with nominalVoltage and a system_base power (in .cimtbl: a BasePower declared before this row)
The options beyond unit:
base='system'forces the system base, as a(pu system)column does on import.power_base=reads a mesh impedance's percent on another power at the same voltage.get_transformer_modeluses it for an end form with a declaredbase_power.- A
PerCentattribute read as'percent'returns the stored number.
get_qty raises for an attribute that is not a CIMUnit. The one exception in the getters is get_regulating_control: a RegulatingControl's targetValue is a plain float, so it builds the CIMUnit for the control's mode and calls .to().
Never re-implement any of it: no * 1e3, no local z_base, no float(obj.r) arithmetic. See
Units for the import side. If get_qty lacks a feature a getter needs, that is an upstream request.
Two kinds of arithmetic are fine. A linear reduction (a mean, a difference, a Kron elimination) of values read in the
caller's unit needs no conversion afterwards, which is how line_impedance.py reduces a matrix. A getter that scales
by a ratio of two ratings (z × S_new / S_old in get_transformer_model) does so on percent values get_qty
returned, never on raw CIMUnit internals.
None or raise¶
| Situation | The getter |
|---|---|
An optional value CIM leaves unset (a line's b, g, zero sequence; a tap's normalStep) |
returns None, never 0.0, so "not modelled" and "zero" stay distinguishable. The spoke decides, with a comment saying why |
A value the concept cannot be read without (a line's r and x, a winding's ratedS) |
raises ValueError naming the class and mRID |
Two places hold the same value and differ (lumped and per-length r; ratedCurrent and a normal limit) |
raises, with the tolerance written down (DISAGREEMENT_REL_TOL) |
An argument that chooses a meaning (which, sign, sections, voltage) |
has no default and is keyword-only, so omitting it is a TypeError; an unknown value raises ValueError: ... must be one of [...] |
| A CIM association that is optional (a tap's control, a device's schedule) | returns None for the whole result (get_equipment_control, get_load_schedule) |
| Something the getter does not read | raises when it is set (get_wire_info raises on rAC75; get_shunt_reactive_power on gPerSection), until a producer writes one |
Each spoke writes its own rule for a None: RAW and MATPOWER write b = 0.0 (the formats' own default), and DSS
writes C1=0 because a blank would let the engine default in line charging.
Semantic rules the getters settle¶
Each ambiguity in CIM is settled once, in one getter, and the choice is the caller's argument.
| Rule | Getter | How it shows up |
|---|---|---|
| Switch state | get_switch_state(switch, which=) |
'actual' reads Switch.open, 'normal' reads normalOpen. get_in_service(equipment, which=) and get_tap_ratio(tap, which=) do the same: the two differ in any model that is not as built |
| Generator sign | get_der_output(equipment, sign=) |
CIM terminal p is positive into equipment, so generation is negative. 'load' returns as stored and 'generation' negates; no spoke negates itself. Nameplate limits are stored in the generation sign and every rating getter returns (min, max) in the sign= you name |
| Per-phase load | phase_power.device_power |
the <Class>Phase children's own p and q when every child has them, else the total split evenly over the phase conductors. Children with values must be exactly those conductors and sum to the total. Loads and DER share it |
| Shunt Q | get_shunt_reactive_power(shunt, sections=, voltage=) |
one formula, Q = bPerSection × V² × sections, and the caller names both factors: sections is 'actual', 'normal' or 'maximum'; voltage is 'nominal' (nomU) or 'base' (the BaseVoltage) |
| Transformer base | get_transformer_model(unit, impedance_unit, base_power=) |
every percent or pu on one declared power base, default winding 1's ratedS; no format picks or rebases its own |
| Raw floats | get_qty |
an attribute that is not a CIMUnit fails fast; never guess kV against V |
| Frequency | the caller | no getter reads a frequency or hard-codes 60 Hz. A derived function takes frequency as an argument, and the spoke passes network.base_frequency |
Unset is None |
all | the spoke decides |
Impedance resolution order¶
A format that takes only sequence values may have to reduce what CIM holds. line_impedance.py does this as a
caller-limited order, not a hidden fallback chain; the steps and the ImpedanceSource values are on the
Lines and wires page. What a new getter with several sources must keep:
derive=caps how far the order may go. The default reads stored values only and raises when they are absent.- Every result carries
source, so logs, tests and goldens show which values are derived. - Two sources present and disagreeing beyond a tolerance raise. The precedence is written down and tested.
- A geometry-capable format never uses the chain. It exports native geometry through the spacing and wire getters, and
takes the phase matrix only where CIM has no geometry.
get_line_phase_impedance_matrixraises on a line that has geometry and noPerLengthImpedance. - Heights come from
get_line_conductor_xy(the spacing's y plusySpacingOffset, or a distance to earth) and raise when absent.
Tests¶
One test file per getter module, cimhub_core/tests/test_getters_<module>.py, run with scripts/test-all.sh core (one
pytest process per package; never one whole-repo pytest). The files share a layout:
| Piece | How it looks |
|---|---|
| Docstring | one line naming the module and what it is tested on |
| Scope | an autouse fixture: with cim_scope(): yield, so load_model's process-wide profile is put back |
| Fixture | a public shape, load_model(SHAPES / "line_by_impedance.cimtbl") with SHAPES = Path(__file__).parents[1] / "src" / "cimhub_core" / "shapes"; or an inline atom written to tmp_path (a header, a few rows) for a case no shape holds; or a CIM object built by hand for a one-attribute getter |
| Expected values | hand-computed from the shape text, not from the getter |
| Errors | pytest.raises(ValueError, match="LinearShuntCompensator 'cap_c1': normalSections is unset"), so the message naming class and mRID is itself a contract |
What a getter's tests assert:
- The value in the declared unit, with
pytest.approx:get_current_limits(line, "kA")against the shape's 340 A. - Every
Nonepath: an unset optional value isNone, and the NamedTuple compares equal to the whole expected tuple, so a silent default shows up. - Every raise: each required value unset, each unknown argument value, each two-sources-disagree case.
- The documented rule once per branch: both signs of a DER, both
whichvalues, eachImpedanceSourcestep and thederivecap. - No mutation: where a getter might be tempted to write back, the object is unchanged.
A new getter that needs a shape row nobody has written is a change to the shapes (see Canonical shapes) and goes through the core owner. Fixtures must have a documented public origin; see Testing.
Anti-patterns¶
| Do not | Do |
|---|---|
line.r.to('ohm') / z_base or value * 1000 in an exporter, or a getter with its own to_float |
get_qty(line, "r", "pu", system_base=...) |
call get_line_sequence_impedance from a GLM or DSS converter on a line that has geometry |
export geometry through the spacing and wire getters |
line.WireConfiguration is not None as the geometry test, or line.PerLengthImpedance as the code |
get_line_geometry(line) and get_line_code(line) |
read WireSpacingInfo, WirePosition or TransformerTankInfo |
read WireSpacing, XYConductorPosition and TransformerTankConfiguration |
| return a dict or a bare tuple, or a different shape per format | one NamedTuple per concept |
value if value else 1.0, a Point(0, 0) fallback, a default height |
return None, or raise |
| write a computed value back onto a CIM object | return it |
| copy a code table into a second spoke | keep it in the spoke until two use it, then move it to core |
.get(value, default) on a native-code table |
cimhub_core.cimtbl.lookup(table, value, slot=..., record_id=...), which raises on an unmapped value |
Checklist¶
- Check upstream (cimtables, cimbuilder, cimgraph, cimprofiles, cim-topology) and
getters/for the capability. - Name the CIM path in the module docstring, and what it does not read.
- Write the NamedTuple, then the getter: unit and meaning arguments,
get_qtyfor every quantity,Nonefor optional values,ValueErrorwithdescribe(obj)for required ones. - Write the tests against a shape or an inline atom; assert units,
None, and every raise. - Add the row to the reference table and a section to its page.
- Run