Loads, shunts and compensators

These getters read the equipment that draws or injects power at a node: EnergyConsumer loads and their voltage response, shunt capacitors and reactors, series compensators, and the schedules that vary a load or a device over time. Calling conventions (keyword-only arguments, unit strings, None versus raising) are on the reference index; this page lists only what is specific to each getter.

Getter Reads Returns
get_phase_loads EnergyConsumer p, q and its phase children PhaseLoads
get_load_response EnergyConsumer.LoadResponse LoadResponse
get_shunt_reactive_power LinearShuntCompensator as Q = b V² n ShuntReactivePower
get_shunt_admittance LinearShuntCompensator as g and b ShuntAdmittance
get_series_compensator SeriesCompensator r, x and varistor SeriesCompensatorData
get_load_schedule a load's LoadGroup and its schedule LoadSchedule or None
get_group_schedule a load group's time series or days LoadSchedule
get_schedule_points a schedule's RegularTimePoint rows SchedulePoints or None
log_dropped_schedules the loads whose schedules a target skips one warning
get_device_schedule an EnergyConnectionSchedule and its points DeviceSchedule or None
device_power the shared per-phase split behind loads and DER DevicePower

The examples on this page load a public test atom through the OpenDSS importer. This setup runs once; each example below runs inside cim_scope(), which restores the profile and model scope that loading a model sets process-wide.

from pathlib import Path

import cimprofiles.cim18.cim18v17 as cim
from cimtables import load_model

from cimhub_core.cimtbl_testing import cim_scope
from cimhub_core.getters.device_schedule import get_device_schedule
from cimhub_core.getters.load import get_load_response, get_phase_loads
from cimhub_core.getters.load_schedule import get_load_schedule, get_schedule_points, log_dropped_schedules
from cimhub_core.getters.series_compensator import get_series_compensator
from cimhub_core.getters.shunt import get_shunt_admittance, get_shunt_reactive_power
from cimhub_opendss import DssImporter, DssReader

ATOMS = Path("cimhub_opendss/tests/atoms")
SHAPES = Path("cimhub_core/src/cimhub_core/shapes")


def dss_network(atom: str):
    path = ATOMS / atom
    return DssImporter(path.stem, time_points={}).to_cim(DssReader(path).read_all())


def find(network, cim_class, mrid):
    return next(obj for obj in network.graph[cim_class].values() if obj.mRID == mrid)

Rules these getters settle

Load sign. Consumption is positive p, as CIM stores it. get_phase_loads has no sign= argument and returns the stored sign. Generation sign is a choice only for DER and machines.

Per-phase power. A device's per-phase p and q are its phase children's own values (EnergyConsumerPhase) when every child has them. When no child has a value, the total is split evenly over the device's phase conductors (the neutral carries none) and split is True. A device with some valued children and some without raises, as does a set of children that is not exactly the device's conductors or whose values do not sum to the total (relative tolerance 1e-6). get_phase_loads and the DER output getter share this rule through device_power.

Shunt reactive power. Q = bPerSection x V^2 x sections. The caller names both factors: sections= picks the attribute that holds the count and voltage= picks the V. A positive Q is a capacitor's.

sections= Attribute Meaning
'actual' sections sections in service now
'normal' normalSections sections in service in the normal state
'maximum' maximumSections all installed sections
voltage= V is Use for
'nominal' nomU, the rating bPerSection was derived on formats that state a rating (OpenDSS, GridLAB-D)
'base' the equipment's BaseVoltage formats that state B at 1 pu (PSS/E RAW)

nomU is across the unit: line to neutral for one phase conductor, line to line otherwise. The base voltage is read in the same form, so a single-phase shunt on a 4.16 kV base uses 4.16 / sqrt(3) kV.

Load groups and schedules. A ConformLoad or NonConformLoad points at a LoadGroup, and the group holds the schedules. A conform load follows its group's curve as a multiplier of its own p and q (a GridLAB-D player, an OpenDSS LoadShape). A non-conform load's group schedule is in power units (value1Unit, value2Unit). The schedule carries only the clock (startTime, timeStep); the points are RegularTimePoint rows in the Parquet sidecar, read through get_schedule_points. A device's own p and q over time (a PV array's or a battery's output) is a different object, the EnergyConnectionSchedule, with EnergyConnectionTimePoint rows. The sidecar tables and their writers are covered in Time series and schedules.

get_phase_loads

get_phase_loads(consumer: EnergyConsumer, active_unit: str = "W", reactive_unit: str = "VAr") -> PhaseLoads

Reads EnergyConsumer.p and .q (both required), the EnergyConsumerPhase children, phaseConnection and grounded. Units are positional and default to SI. Phases come from the terminal's PhaseCode through get_conductor_phases (see topology), neutral removed, in PhaseCode order (A, B, C, s1, s2).

PhaseLoads fields:

Field Meaning
phases the phase conductors, no neutral
connection PhaseShuntConnectionKind (Y, D, ...) or None
grounded bool or None
total PhasePower(p, q) in the caller's units
per_phase {SinglePhaseKind: PhasePower} in the caller's units
split True: the total split evenly; False: the children's own values

Raises ValueError when p or q is unset, when the PhaseCode is not a set of conductors, or for the per-phase cases above. It never returns None.

with cim_scope():
    network = dss_network("load/loads.dss")
    loads = get_phase_loads(find(network, cim.EnergyConsumer, "ld_ca"), "kW", "kVAr")
    print([phase.value for phase in loads.phases], loads.connection.value, loads.split)
    print(loads.total)
    print(loads.per_phase[cim.SinglePhaseKind.A])
# ['A', 'C'] D True
# PhasePower(p=170.0, q=82.33475782243494)
# PhasePower(p=85.0, q=41.16737891121747)

Called by cimhub_opendss, cimhub_gridlabd, cimhub_gdm and cimhub_raw.

get_load_response

get_load_response(consumer: EnergyConsumer) -> LoadResponse

Reads EnergyConsumer.LoadResponse, a LoadResponseCharacteristic. It has two forms, chosen by exponentModel; the fields of the other form are None.

Field exponential=False (ZIP) exponential=True
exponential False True
p_impedance, p_current, p_power pConstantImpedance, pConstantCurrent, pConstantPower (fractions) None
q_impedance, q_current, q_power qConstantImpedance, qConstantCurrent, qConstantPower (fractions) None
p_exponent, q_exponent None pVoltageExponent, qVoltageExponent

ZIP fractions are returned as stored: zeros stay zeros, nothing is normalised. Each set of three must sum to 1 (relative tolerance 1e-6). Raises ValueError when the load has no LoadResponse, when exponentModel is unset, when any value the form needs is unset, or when a ZIP set does not sum to 1.

with cim_scope():
    network = dss_network("load/loads.dss")
    constant_current = get_load_response(find(network, cim.EnergyConsumer, "ld_ca"))
    cvr = get_load_response(find(network, cim.EnergyConsumer, "ld_cvr1"))
    print(constant_current.exponential, constant_current.p_current, constant_current.p_power)
    print(cvr.exponential, cvr.p_exponent, cvr.q_exponent)
# False 1.0 0.0
# True 0.8 3.0

Called by cimhub_opendss, cimhub_gridlabd, cimhub_gdm and cimhub_raw.

get_shunt_reactive_power

get_shunt_reactive_power(shunt: LinearShuntCompensator, unit: str = "VAr", *, sections: str, voltage: str,
                         voltage_unit: str = "V") -> ShuntReactivePower

Reads bPerSection, the section count named by sections=, and either nomU or the base voltage named by voltage= (rules above). sections= and voltage= have no defaults. nomQ is not read.

Field Meaning
phases the phase conductors, no neutral
connection, grounded phaseConnection and grounded, each None when unset
voltage the V in Q = b V² n, in voltage_unit
sections the section count used
total Q in unit
per_phase {SinglePhaseKind: float}, the total split evenly over the phases

Raises ValueError for a voltage= or sections= outside the tables above, for a shunt that is not a LinearShuntCompensator, for a set gPerSection or any per-phase bPerSection (neither is read yet), for an unset bPerSection, nomU or section count, and for a missing BaseVoltage under voltage='base'.

with cim_scope():
    network = dss_network("capacitor/caps.dss")
    shunt = find(network, cim.LinearShuntCompensator, "cap_c3")
    q = get_shunt_reactive_power(shunt, "kVAr", sections="actual", voltage="nominal", voltage_unit="kV")
    print(q.total, q.voltage, q.sections, q.per_phase[cim.SinglePhaseKind.A])
    off = get_shunt_reactive_power(find(network, cim.LinearShuntCompensator, "cap_open"), "kVAr",
                                   sections="actual", voltage="nominal", voltage_unit="kV")
    print(off.total)
# 600.0 4.16 1.0 200.0
# 0.0

Called by cimhub_opendss, cimhub_gridlabd and cimhub_gdm.

get_shunt_admittance

get_shunt_admittance(shunt: LinearShuntCompensator, unit: str = "S", *, sections: str,
                     base_power=None) -> ShuntAdmittance

The form for bus-branch formats that write a shunt as G + jB. It returns the conductance and susceptance of the sections named by sections= ('actual', 'normal' or 'maximum'): gPerSection and bPerSection times the section count.

unit is 'S' for siemens, or 'pu' for per unit on the shunt's nomU and the system base power. The pu form needs base_power (network.base_power). gPerSection unset gives g = None, like any unset optional value, and the spoke decides what to write (RAW writes 0, its spec default); bPerSection is required.

Field Meaning
g conductance of the sections in service, in unit; None when gPerSection is unset
b susceptance of the sections in service, in unit
sections the section count used

Raises ValueError for a unit other than 'S' or 'pu', a sections= outside the table above, a shunt that is not a LinearShuntCompensator, a per-phase bPerSection, or an unset bPerSection or section count. A 'pu' read without base_power raises from cimtables.

with cim_scope():
    network = dss_network("capacitor/caps.dss")
    shunt = find(network, cim.LinearShuntCompensator, "cap_c3")
    print(get_shunt_admittance(shunt, "S", sections="normal"))
# ShuntAdmittance(g=None, b=0.03467085798816568, sections=1)

Called by cimhub_raw.

get_series_compensator

get_series_compensator(compensator: SeriesCompensator, unit: str = "ohm", *, base_power=None) -> SeriesCompensatorData

Reads r, x, r0, x0 and the varistor attributes. unit is 'ohm' or 'pu'; 'pu' is on the compensator's BaseVoltage and base_power (network.base_power), the same way the line getters read a line (see lines and wires).

Field Meaning
r, x positive-sequence resistance and reactance per phase, in unit; required
r0, x0 zero-sequence values in unit, or None
compensator_type CompensatorKind (capacitor, reactor) or None
varistor_present bool or None
varistor_rated_current amperes, or None
varistor_voltage_threshold volts, or None

Raises ValueError for an object that is not a SeriesCompensator, a unit other than 'ohm' or 'pu', or an unset r or x.

with cim_scope():
    network = load_model(SHAPES / "series_compensator.cimtbl")
    compensator = next(iter(network.graph[cim.SeriesCompensator].values()))
    data = get_series_compensator(compensator)
    print(data.r, data.x, data.x0, data.compensator_type)
# 0.0 14.798307 14.798307 None

Called by cimhub_opendss, cimhub_gridlabd, cimhub_gdm and cimhub_raw.

get_load_schedule

get_load_schedule(consumer: EnergyConsumer) -> LoadSchedule | None

Follows ConformLoad -> ConformLoadGroup <- ConformLoadSchedule (or the NonConformLoad equivalents). Returns None for a plain EnergyConsumer and for a conform or non-conform load with no group.

Field Meaning
conform True: a ConformLoad (the curve is a multiplier); False: a NonConformLoad (power units)
group the LoadGroup; kept even when it has no schedule, so its name survives
schedule the group's one time series, or None
start the time series' startTime, an ISO 8601 string with its offset, or None
step the time series' timeStep in seconds, or None
days the group's schedules that belong to a Season or DayType (a recurring day), sorted by mRID; empty for a time series

A group has either one time series (a schedule with no Season and no DayType: an OpenDSS LoadShape or a GridLAB-D player, counted from its startTime) or recurring days (a GridLAB-D schedule). Two time series, or a time series beside days, raise ValueError.

with cim_scope():
    network = dss_network("loadshape/loadshapes.dss")
    found = get_load_schedule(find(network, cim.ConformLoad, "ld_r1"))
    print(found.conform, found.group.mRID, found.schedule.mRID, found.start, found.step)
    print(get_load_schedule(find(network, cim.ConformLoad, "ld_f1")).schedule)
    print(get_load_schedule(find(network, cim.EnergyConsumer, "ld_static")))
# True lg_res ls_res 2020-01-01T01:00:00+00:00 3600.0
# None
# None

ld_f1 has a group but no schedule; ld_static is a plain consumer. Called by cimhub_opendss, cimhub_gridlabd and cimhub_gdm.

get_group_schedule

get_group_schedule(group: ConformLoadGroup | NonConformLoadGroup) -> LoadSchedule

get_load_schedule for a group: the same LoadSchedule and the same rules, for an exporter that walks schedules rather than loads (the OpenDSS LoadShape writer skips every schedule that is not its group's time series, so a recurring day is no LoadShape). Another object raises ValueError. Called by cimhub_opendss.

get_schedule_points

get_schedule_points(schedule: RegularIntervalSchedule, rows_by_schedule: dict) -> SchedulePoints | None

Reads one schedule's points from the sidecar. rows_by_schedule is cimhub_core.time_points.rows_by_schedule of the RegularTimePoint table ({uri: rows}), so this module itself needs no pyarrow. Returns None when the schedule has no rows.

Field Meaning
value1 one float per point, sequenceNumber 0, 1, ...; a multiplier for a conform load
value2 one float per point, or None when value2 is unset at every point

Raises ValueError when the sequence numbers are not 0, 1, 2, ... in order, when value1 is unset at any point, or when value2 is set at only some points. The values are as stored: a column in a unit (W, VAr) keeps its value1Multiplier/value2Multiplier for the caller to read with the unit (GDM's kilowatt), and a multiplier column (unit none or unset) with a multiplier other than none raises, since it would be read that many times off.

from cimhub_core import time_points

with cim_scope():
    time_points_by_class = {}
    path = ATOMS / "loadshape/loadshapes.dss"
    network = DssImporter("loadshapes", time_points=time_points_by_class).to_cim(DssReader(path).read_all())
    rows = time_points.rows_by_schedule(time_points_by_class["RegularTimePoint"])
    schedule = get_load_schedule(find(network, cim.ConformLoad, "ld_r1")).schedule
    print(get_schedule_points(schedule, rows))
# SchedulePoints(value1=[0.5, 0.75, 1.0, 0.8], value2=[0.4, 0.6, 0.9, 0.7])

Called by cimhub_opendss, cimhub_gridlabd and cimhub_gdm.

log_dropped_schedules

log_dropped_schedules(consumers, target: str) -> None

For an exporter whose target format writes loads static. It runs get_load_schedule on each consumer and emits one WARNING on the cimhub_core.getters.load_schedule logger that names the groups with a schedule or days, sorted by name (the mRID when a group has none). It logs nothing when no load has a schedule, and returns None either way.

import logging

logging.basicConfig(format="%(levelname)s %(message)s")
with cim_scope():
    network = dss_network("loadshape/loadshapes.dss")
    log_dropped_schedules(network.graph[cim.ConformLoad].values(), "PSS/E RAW")
# WARNING PSS/E RAW: the schedules of 3 load group(s) are not exported; their loads are written static: ['com', 'ind', 'res']

Called by cimhub_raw.

get_device_schedule

get_device_schedule(equipment: EnergyConnection, rows_by_schedule: dict, p_unit: str, q_unit: str, *,
                    sign: str) -> DeviceSchedule | None

Reads an EnergyConnectionSchedule on a PV system, battery or machine, with its points from the EnergyConnectionTimePoint sidecar rows (time_points.rows_by_schedule of that table). sign= is 'load' (as stored) or 'generation' (negated), the same as get_der_output; it has no default. The sidecar stores p and q in W and VAr in the load sign.

Field Meaning
schedule the EnergyConnectionSchedule
times the instant each point takes effect, UTC datetimes
step the one interval between points in seconds; None when the points are unevenly spaced or there is one
p list in p_unit and the caller's sign, or None when the schedule carries no p
q list in q_unit and the caller's sign, or None

Returns None when the equipment has no schedule with rows. Raises ValueError for a sign other than 'load' or 'generation', two schedules with points, an interpolationKind other than previous (a sample holds until the next; unset reads as previous), a p or q column null at only some points, and points with neither p nor q.

with cim_scope():
    time_points_by_class = {}
    path = ATOMS / "loadshape/devices.dss"
    network = DssImporter("devices", time_points=time_points_by_class).to_cim(DssReader(path).read_all())
    rows = time_points.rows_by_schedule(time_points_by_class["EnergyConnectionTimePoint"])
    battery = find(network, cim.PowerElectronicsConnection, "storage_s1")
    found = get_device_schedule(battery, rows, "kW", "kVAr", sign="generation")
    print(found.schedule.mRID, found.step, found.p, found.q)
# storage_s1_yearly 3600.0 [50.0, -50.0, -1.0, 80.0] None

Called by cimhub_opendss.

device_power

device_power(device, children, active_unit: str, reactive_unit: str) -> DevicePower

A helper in cimhub_core.getters.phase_power (from cimhub_core.getters.phase_power import device_power), listed here because it is where the per-phase rule above lives. get_phase_loads and get_der_output are thin wrappers: the load passes its EnergyConsumerPhase children and the inverter its PowerElectronicsConnectionPhase children (a machine passes none). Spokes call the wrappers, not this function. DevicePower has the fields phases, total (PhasePower), per_phase and split, as PhaseLoads without connection and grounded. PhasePower is the (p, q) pair, and SUM_REL_TOL = 1e-6 is the tolerance of the sum check. active_unit must be a W unit and reactive_unit a VAr unit, or it raises: pint converts W and VAr into each other, so a swapped pair would otherwise pass unnoticed.