Sources, DER and machines

These getters read what puts power into the network: the energy source at the substation, inverter-based resources (PowerElectronicsConnection with its PV and battery units) and synchronous machines. Calling conventions are on the reference index. The sign rules below are the part that differs from every other getter page.

Getter Reads Returns
get_source EnergySource voltage and Thevenin impedance Source
get_der_output p and q of an inverter or a machine DerOutput
get_inverter_rating PowerElectronicsConnection nameplate InverterRating
get_inverter_unit the one PowerElectronicsUnit of a connection the unit
get_inverter_units each unit's share of a shared connection tuple of InverterUnitShare
get_photovoltaic_unit PhotoVoltaicUnit limits and irradiance PhotoVoltaicRating
get_photovoltaic_datasheet SolarArrayInfo and SolarPanelInfo PhotoVoltaicDatasheet or None
get_inverter_datasheet GenerationInverterInfo or StorageInverterInfo InverterDatasheet or None
get_unit_limits active power limits of a GeneratingUnit or PowerElectronicsUnit UnitLimits
get_battery_unit BatteryUnit limits, energy, efficiency, state BatteryRating
get_machine_rating SynchronousMachine nameplate and mode MachineRating
get_machine_impedance SynchronousMachine r and sequence impedances MachineImpedance

A device's own schedule over time (a PV array's or battery's output curve) is get_device_schedule. Terminal, phase and node lookups are on the topology page.

The examples run a public test atom through the OpenDSS importer (and one GridLAB-D atom for the datasheets), inside cim_scope(), which restores the profile and model scope that loading a model sets process-wide.

from pathlib import Path

import cimprofiles.cim18.cim18v17 as cim
from cimtables import load_model

from cimhub_core.cimtbl_testing import cim_scope
from cimhub_core.getters.der import *
from cimhub_core.getters.source import get_source
from cimhub_gridlabd.glm_reader import GlmReader
from cimhub_gridlabd.importer.glm_to_cimtbl import glm_to_cim
from cimhub_opendss import DssImporter, DssReader

DSS_ATOMS = Path("cimhub_opendss/tests/atoms")
GLM_ATOMS = Path("cimhub_gridlabd/tests/atoms")


def dss_network(atom: str):
    path = DSS_ATOMS / atom
    return DssImporter(path.stem).to_cim(DssReader(path).read_all())


def find(network, cim_class, mrid):
    return next(obj for obj in network.graph[cim_class].values() if obj.mRID == mrid)

The sign convention

CIM's terminal sign is the load's: p and q are positive into the equipment. A generator, a PV array and a discharging battery therefore carry negative p. A spoke never negates on its own; it asks the getter for the sign its format wants with sign=, a keyword that has no default:

sign= p and q returned Limit pairs returned
'load' as stored (generation negative) negated and swapped, so still (min, max)
'generation' negated (positive output) as stored

Limits. Nameplate limits (minQ/maxQ, minP/maxP, a GeneratingUnit's minOperatingP/maxOperatingP) are written in the generation sign: a PV unit's maxP is its output, a battery's minP is its charging power (negative). Every limit pair comes back as (min, max) in the sign you asked for. For 'load' the stored maximum is negated into the new minimum, and the stored minimum into the new maximum. Zero stays 0.0, never -0.0.

A minimum above its maximum raises ValueError (a producer wrote the load sign into a generation-sign field). The exception is get_unit_limits, which returns the pair as stored.

BatteryUnit.idlingP is a loss, "consumed while idling", and is returned as stored in either sign.

Voltage. ratedU is line to line, as stored.

get_source

get_source(source: EnergySource, *, angle_unit: str, voltage_unit: str = "V", impedance_unit: str = "ohm",
           base_power=None) -> Source

Reads nominalVoltage and voltageMagnitude (both required), voltageAngle, and the Thevenin impedance r, x, r0, x0, r2, x2. angle_unit ('deg' or 'rad') has no default. impedance_unit is 'ohm' or 'pu'; 'pu' is on the source's BaseVoltage and base_power (network.base_power).

Field Meaning
phases the source's conductors (get_conductor_phases, in PhaseCode order, neutral included if present)
nominal_u nominalVoltage in voltage_unit
magnitude voltageMagnitude in voltage_unit
magnitude_pu magnitude / nominal_u
angle voltageAngle in angle_unit, or None
impedance SourceImpedance(r, x, r0, x0, r2, x2), each in impedance_unit or None when unset

An unset impedance stays None: the spoke decides what its format assumes. Raises ValueError for an impedance_unit other than 'ohm' or 'pu', an unset nominalVoltage or voltageMagnitude, a source with no terminals, or (from cimtables) 'pu' without base_power.

with cim_scope():
    network = dss_network("vsource/ohms.dss")
    source = get_source(next(iter(network.graph[cim.EnergySource].values())), angle_unit="deg", voltage_unit="kV")
    print(source.nominal_u, source.magnitude_pu, source.angle)
    print(source.impedance.x, source.impedance.r2)
# 4.16 1.0 0.0
# 0.0001 None

Called by cimhub_opendss, cimhub_gridlabd and cimhub_gdm.

get_der_output

get_der_output(equipment: PowerElectronicsConnection | RotatingMachine, active_unit: str = "W",
               reactive_unit: str = "VAr", *, sign: str) -> DerOutput

Reads p and q (both required) of an inverter or a machine, in the requested sign. Per-phase values follow the rule on the loads page: an inverter's PowerElectronicsConnectionPhase values when every child has them, otherwise the total split evenly. A machine's phase objects hold no p or q, so a machine's total is always split evenly.

Field Meaning
phases the phase conductors, no neutral
connection PhaseShuntConnectionKind for an inverter; None for a machine, which has none in cim18v17
total PhasePower(p, q) in the caller's units and sign
per_phase {SinglePhaseKind: PhasePower} in the caller's units and sign
split True: the total split evenly; False: the children's own values

Raises ValueError for a sign other than 'load' or 'generation', for equipment that is neither a PowerElectronicsConnection nor a RotatingMachine, and for the per-phase cases on the loads page.

with cim_scope():
    network = dss_network("der/der.dss")
    inverter = find(network, cim.PowerElectronicsConnection, "pv_house")
    print(get_der_output(inverter, "kW", "kVAr", sign="generation").total)
    print(get_der_output(inverter, "kW", "kVAr", sign="load").total)
    print([phase.value for phase in get_der_output(inverter, "kW", "kVAr", sign="load").phases])
# PhasePower(p=4.0, q=0.0)
# PhasePower(p=-4.0, q=0.0)
# ['s1', 's2']

Called by cimhub_opendss, cimhub_gridlabd, cimhub_gdm and cimhub_raw.

get_inverter_rating

get_inverter_rating(connection: PowerElectronicsConnection, apparent_unit: str = "VA", reactive_unit: str = "VAr", *,
                    sign: str, voltage_unit: str = "V") -> InverterRating

The connection's nameplate: ratedS and ratedU (both required), minQ/maxQ in the requested sign, and maxIFault.

Field Meaning
rated_s ratedS in apparent_unit
rated_u ratedU in voltage_unit, line to line
min_q, max_q the q limits as (min, max) in reactive_unit and the caller's sign, each None when unset
max_fault_current maxIFault, per unit of rated current, or None

Raises ValueError for a bad sign, an unset ratedS or ratedU, a ratedS, ratedU or maxIFault of 0 or less, or a minQ above maxQ.

with cim_scope():
    network = dss_network("der/der.dss")
    inverter = find(network, cim.PowerElectronicsConnection, "pv_house")
    rating = get_inverter_rating(inverter, "kVA", "kVAr", sign="generation", voltage_unit="kV")
    print(rating.rated_s, round(rating.rated_u, 3), rating.min_q, rating.max_q, round(rating.max_fault_current, 3))
# 5.0 0.208 -5.0 5.0 1.111

Called by cimhub_opendss, cimhub_gridlabd, cimhub_gdm and cimhub_raw.

get_inverter_unit

get_inverter_unit(connection: PowerElectronicsConnection) -> PowerElectronicsUnit

The connection's one PowerElectronicsUnit, a PhotoVoltaicUnit or a BatteryUnit. This is the strict form: no unit or several raise ValueError. Use get_inverter_units when several can share a connection. Called by cimhub_raw.

get_inverter_units

get_inverter_units(connection: PowerElectronicsConnection, active_unit: str = "W", reactive_unit: str = "VAr", *,
                   sign: str) -> tuple[InverterUnitShare, ...]

CIM lets several units share one connection, a PV array and a battery behind one inverter. A format with one DC device per inverter takes each unit's share of the connection. The share is the unit's maxP over the units' total maxP. share is the fraction a spoke applies to the connection's ratedS and q limits; the getter itself splits only p and q.

InverterUnitShare fields:

Field Meaning
unit the PowerElectronicsUnit
share the fraction of the connection (1.0 for a single unit)
p the unit's active power in active_unit and the caller's sign
q share x the connection's q in reactive_unit and the caller's sign (a unit has no q of its own)

The units come back in the connection's order. Rules for p:

  • one unit is the whole connection, and its own p, when set, must equal the connection's;
  • several units each need a positive maxP, which sets the share;
  • when every unit has its own p (cim18v17's PowerElectronicsUnit.p) those are used and must sum to the connection's p (relative tolerance 1e-6); when none has, each takes share x the connection's p.

Raises ValueError for a bad sign, a connection with no unit, a missing or non-positive maxP among several units, units where only some have p, or a p sum that disagrees with the connection.

with cim_scope():
    network = dss_network("der/der.dss")
    shares = get_inverter_units(find(network, cim.PowerElectronicsConnection, "storage_share"), "kW", "kVAr",
                                sign="generation")
    print([(type(item.unit).__name__, item.share, item.p, item.q) for item in shares])
# [('BatteryUnit', 1.0, 50.0, 0.0)]

Called by cimhub_opendss, cimhub_gridlabd and cimhub_gdm.

get_photovoltaic_unit

get_photovoltaic_unit(unit: PhotoVoltaicUnit, active_unit: str = "W", irradiance_unit: str = "W/m2", *,
                      sign: str) -> PhotoVoltaicRating
Field Meaning
min_p, max_p minP and maxP as (min, max) in active_unit and the caller's sign, each None when unset
irradiance the irradiance attribute in irradiance_unit (a GridAPPS-D extension), or None

Raises ValueError for a bad sign, a unit that is not a PhotoVoltaicUnit, or minP above maxP.

with cim_scope():
    network = dss_network("der/der.dss")
    unit = get_inverter_unit(find(network, cim.PowerElectronicsConnection, "pv_house"))
    print(get_photovoltaic_unit(unit, "kW", sign="generation"))
    print(get_photovoltaic_unit(unit, "kW", sign="load"))
# PhotoVoltaicRating(min_p=0.0, max_p=5.0, irradiance=800.0)
# PhotoVoltaicRating(min_p=-5.0, max_p=0.0, irradiance=800.0)

Called by cimhub_opendss, cimhub_gridlabd and cimhub_gdm.

get_photovoltaic_datasheet

get_photovoltaic_datasheet(unit: PhotoVoltaicUnit, angle_unit: str = "deg",
                           irradiance_unit: str = "W/m2") -> PhotoVoltaicDatasheet | None

Reads the unit's AssetDatasheet, a SolarArrayInfo, and the array's one SolarPanelInfo. Returns None when the unit has no datasheet.

Field Meaning
tilt, azimuth tiltAngle and orientationAzimuth in angle_unit, or None
shading shadingFactor in percent, or None
panel_efficiency the panel's efficiency in percent; None without a panel
reference_irradiance the panel's referenceIrradiation in irradiance_unit; None without a panel

Raises ValueError for a unit that is not a PhotoVoltaicUnit, a datasheet that is not a SolarArrayInfo, or more than one panel. Called by cimhub_gridlabd.

get_inverter_datasheet

get_inverter_datasheet(connection: PowerElectronicsConnection, apparent_unit: str = "VA",
                       reactive_unit: str = "VAr", active_unit: str = "W") -> InverterDatasheet | None

Reads the connection's AssetDatasheet, a GenerationInverterInfo or a StorageInverterInfo. Returns None when there is none; another datasheet class raises ValueError. The sign is not a choice here: datasheet values are magnitudes.

Field Meaning
apparent_power_max apparentPowerMaximum in apparent_unit, or None
reactive_injected_max reactivePowerInjectedMax in reactive_unit, or None
reactive_absorbed_max reactivePowerAbsorbedMax in reactive_unit, or None
charge_rate_max chargeRateActiveMax in active_unit; a StorageInverterInfo only, otherwise None
with cim_scope():
    path = GLM_ATOMS / "inverter/inverter.glm"
    network = glm_to_cim(GlmReader(path).read_all(), name="inverter_case")
    inverter = find(network, cim.PowerElectronicsConnection, "pv_inv_pv1")
    unit = get_inverter_unit(inverter)
    print(get_inverter_datasheet(inverter, "kVA", "kVAr").apparent_power_max)
    panel = get_photovoltaic_datasheet(unit)
    print(panel.tilt, panel.azimuth, panel.shading, panel.panel_efficiency)
# 10.0
# 45.0 180.0 100.0 20.0

Called by cimhub_gridlabd.

get_unit_limits

get_unit_limits(unit: GeneratingUnit | PowerElectronicsUnit, active_unit: str = "W", *, sign: str) -> UnitLimits

The active power limits of any unit as UnitLimits(min_p, max_p): minOperatingP/maxOperatingP for a GeneratingUnit, minP/maxP for a PowerElectronicsUnit, each None when unset. Unlike the other limit getters it does not raise on a minimum above its maximum. A source such as a PSS/E case can hold PB above PT on a unit that is out of service, and an exporter maps the pair as written. Raises ValueError for a bad sign or any other class.

with cim_scope():
    network = dss_network("der/der.dss")
    unit = get_inverter_unit(find(network, cim.PowerElectronicsConnection, "pv_house"))
    print(get_unit_limits(unit, "kW", sign="load"))
# UnitLimits(min_p=-5.0, max_p=0.0)

Called by cimhub_raw.

get_battery_unit

get_battery_unit(unit: BatteryUnit, active_unit: str = "W", energy_unit: str = "Wh", *, sign: str) -> BatteryRating
Field Meaning
min_p, max_p minP (charging, negative in generation sign) and maxP as (min, max) in the caller's sign
rated_e, stored_e, minimum_e ratedE, storedE, minimumE in energy_unit
charging_efficiency, discharging_efficiency percent
idling_p idlingP in active_unit, as stored in either sign
state BatteryStateKind (charging, discharging, ...) or None

Every field is None when unset. Raises ValueError for a bad sign, a unit that is not a BatteryUnit, a ratedE of 0 or less, or minP above maxP.

with cim_scope():
    network = dss_network("der/der.dss")
    battery = get_inverter_unit(find(network, cim.PowerElectronicsConnection, "storage_ess"))
    rating = get_battery_unit(battery, "kW", "kWh", sign="generation")
    print(rating.min_p, rating.max_p, rating.rated_e, rating.charging_efficiency, rating.idling_p)
    print(rating.state.value)
# -250.0 250.0 500.0 90.0 2.5
# discharging

Called by cimhub_opendss, cimhub_gridlabd and cimhub_gdm.

get_machine_rating

get_machine_rating(machine: SynchronousMachine, apparent_unit: str = "VA", reactive_unit: str = "VAr", *,
                   sign: str, voltage_unit: str = "V") -> MachineRating
Field Meaning
rated_s, rated_u ratedS in apparent_unit and ratedU in voltage_unit (line to line); both required
rated_power_factor ratedPowerFactor, or None
min_q, max_q the q limits as (min, max) in the caller's sign, each None when unset
q_percent qPercent, a share of a coordinated reactive control, in percent, or None
reference_priority referencePriority or None
type SynchronousMachineKind or None
operating_mode SynchronousMachineOperatingMode or None
earthing bool or None

Raises ValueError for a bad sign, an object that is not a SynchronousMachine, an unset ratedS or ratedU, either of them 0 or less, or minQ above maxQ.

with cim_scope():
    network = dss_network("generator/gens.dss")
    machine = find(network, cim.SynchronousMachine, "gen_delta")
    rating = get_machine_rating(machine, "kVA", "kVAr", sign="generation", voltage_unit="kV")
    print(rating.rated_s, rating.rated_u, rating.type.value, rating.earthing)
    print(get_der_output(machine, "kW", "kVAr", sign="generation").total.p)
# 250.0 0.48 generator False
# 50.0

Called by cimhub_opendss and cimhub_raw.

get_machine_impedance

get_machine_impedance(machine: SynchronousMachine, unit: str = "ohm") -> MachineImpedance

Reads r, r0, x0, r2 and x2, in ohm or in pu on the machine's own ratedU and ratedS; an unset value is None. MachineImpedance has the fields r, r0, x0, r2, x2. It has no positive-sequence x: cim18v17 has no machine reactance. Machine short-circuit data (ikk, mu, star point earthing), voltage limits and capability curves, wind units and AsynchronousMachine are not read by any DER getter.

Raises ValueError for a unit other than 'ohm' or 'pu', or an object that is not a SynchronousMachine.

with cim_scope():
    network = dss_network("generator/gens.dss")
    print(get_machine_impedance(find(network, cim.SynchronousMachine, "gen_delta")))
# MachineImpedance(r=None, r0=None, x0=None, r2=None, x2=None)

Called by cimhub_raw.