Using the getters

A getter reads one CIM concept from one CIM object and returns plain floats, enums and NamedTuples. The code on this page runs against feeder.cimtbl, the model of the quick start, loaded like this:

import cimprofiles.cim18.cim18v17 as cim
import cimtables

from cimhub_core.cimtbl_testing import cim_scope

with cim_scope():
    network = cimtables.load_model('feeder.cimtbl')


def find(cim_class, mrid):
    return next(obj for obj in network.graph[cim_class].values() if obj.mRID == mrid)

A model read from CIM XML with cim-graph works the same way. The getters take cim18v17 objects and nothing else.

Name the unit

CIM stores SI. A getter takes the unit you want and converts once, through cimtables.graph_write.get_qty. The units are pint strings, such as 'kW', 'kV', 'ohm/km' or 'uS/km'.

from cimhub_core.getters.load import get_phase_loads

load = find(cim.EnergyConsumer, 'ld_n1')
print(get_phase_loads(load, 'kW', 'kVAr').total)   # PhasePower(p=1155.0, q=660.0)
print(get_phase_loads(load).total)                 # PhasePower(p=1155000.0, q=660000.0)

Where a getter has a default it is usually the SI unit, so a call with no unit argument returns W, VAr, V, ohm or S. The exceptions are angles ('deg'), time ('s'), a transformer's impedance_unit ('percent') and a few others, such as currents ('A') and irradiance ('W/m2'). Some getters have no default, because the unit is a decision: get_source makes you pass angle_unit=, any pint angle unit such as 'deg' or 'rad'.

A unit with the wrong dimension raises pint's DimensionalityError. Active and reactive power have the same dimension, so 'kVAr' is accepted for an active power and gives a number in the wrong column. Pass the unit that matches the argument's name.

Read NamedTuple fields by name

Results are NamedTuples, so every field has a name and the units of the fields are fixed by the call.

loads = get_phase_loads(find(cim.EnergyConsumer, 'ld_n2'), 'kW', 'kVAr')
print(loads.phases)             # (A, B, C) as SinglePhaseKind members
print(loads.split)              # False: each phase holds its own values
for phase, power in loads.per_phase.items():
    print(phase.value, power.p, power.q)

Phases are cim.SinglePhaseKind members, in the order A, B, C, s1, s2, N. A result keyed by phase is a dict keyed by those members. Enumerations such as connection and form are CIM or core enums; read .value or .name.

None is not zero

A field of a result is None when CIM leaves the value unset. Zero and unset are different statements, and a getter never turns one into the other.

from cimhub_core.getters.line_impedance import ImpedanceSource, get_line_sequence_impedance

line = find(cim.ACLineSegment, 'ln_trunk')
z = get_line_sequence_impedance(line, derive=ImpedanceSource.PER_LENGTH_SEQ)
print(z.r0, z.g)    # 0.359664 None

Your code decides what an unset value means in your format. Which fields of a result can be None is in the reference; the type annotation of the field says it too (float | None).

get_shunt_admittance follows the same rule: g is None when the shunt's gPerSection is unset.

Errors

A getter raises ValueError when the model cannot be read as asked. Where the fault is in one object, the message starts with its class and mRID. A bad argument is named instead. A getter does not fall back to a guess.

Message Meaning
EnergyConsumer 'ld_n1': p is unset The getter needs this attribute and CIM has none.
which must be one of ['actual', 'normal'], not 'now' A decision argument was not one of its values.
unit must be one of ['ohm', 'pu'], not 'S' The getter takes a fixed set of unit words, not any pint unit.
ACLineSegment 'ln_trunk': no sequence impedance within derive=LUMPED (...) No source of the value is within the cap you allowed.
... have different phases ..., ... has no Terminals The model's connectivity is incomplete.
ConformLoadGroup '...': 2 schedules with no Season or DayType ... Two places hold the value, and CIM allows one.
... a pu/percent impedance needs a rated From* reference, or a BaseVoltage ... A per-unit read has no base. See Units.
try:
    get_line_sequence_impedance(line)
except ValueError as error:
    print(error)

A missing keyword raises TypeError, as for any Python function. get_der_output(inverter, 'kW', 'kVAr') without sign= does.

Arguments that carry a decision

Some arguments are keyword-only, with no default, so that a call says what it means. A getter that would have returned the wrong answer for half its callers has one of these.

Argument Getters Values
sign= the DER getters, get_device_schedule 'load' as CIM stores it, 'generation' negated. See Units.
which= get_switch_state, get_in_service, get_tap_ratio, get_tap_voltage 'actual' or 'normal' (taps also 'low', 'high')
derive= get_line_sequence_impedance, get_line_sequence_impedance_per_length an ImpedanceSource
expand_sequence= get_line_phase_impedance_matrix True to build a phase matrix from a sequence code, which assumes a transposed line; without it the getter raises
base_power= line, source, shunt and transformer getters network.base_power, for 'pu' and 'percent'
sections=, voltage= get_shunt_reactive_power which section count, which voltage
form= get_base_voltage 'LL' or 'LN'
topological= get_terminal_nodes read the bus-branch TopologicalNode instead of the ConnectivityNode

which=: actual or normal

CIM keeps a state and its normal value apart: Switch.open and normalOpen, inService and normallyInService. They differ in any model that is not as built, so there is no default.

from cimhub_core.getters.in_service import get_in_service

print(get_in_service(line, which='actual'))   # None: the file does not say

get_switch_state returns True for open, and raises when the attribute is unset. get_in_service returns None.

derive=: how far a line may look

A line's impedance can be on the line itself, in a per-length code, in a matrix, or only in its geometry. ImpedanceSource names these steps in order, and derive= is the furthest the getter may go.

ImpedanceSource Reads
LUMPED ACLineSegment.r, x, bch, gch (and the zero-sequence ones)
PER_LENGTH_SEQ a PerLengthSequenceImpedance, times the length
MATRIX_REDUCED a PerLengthPhaseImpedance reduced to sequence values
GEOMETRY a WireConfiguration's spacing and wires through line constants (not built: a line with geometry and no lumped values raises NotImplementedError)

The default for get_line_sequence_impedance is LUMPED, and for the per-length getter it is PER_LENGTH_SEQ. The result's source field says which step produced it. When the lumped values and a per-length source both lie within the cap and disagree, the getter raises; when they agree, the lumped values win. With lumped values the per-length source is only a check: it is skipped when the line has no length, and geometry is never read.

z = get_line_sequence_impedance(line, 'ohm', derive=ImpedanceSource.PER_LENGTH_SEQ)
print(z.source.name, round(z.r, 4))      # PER_LENGTH_SEQ 0.2134

base_power=: the per-unit base

'pu' and 'percent' need a base power. Pass network.base_power, which is the model's BasePower object. See Units, bases and signs.

sections= and voltage=: a shunt

get_shunt_reactive_power gives the reactive power of the sections in service. sections= is 'actual', 'normal' or 'maximum', and voltage= is 'nominal' (the shunt's nomU) or 'base' (its BaseVoltage). The reactive power is b V² n, so the voltage you choose changes the answer.

Where frequency and the system base come from

No getter takes a frequency. A line code carries its own calculatedFrequency, and the model carries a system frequency and a system base power:

from cimhub_core.getters.line_impedance import get_line_code

print(network.base_power.to('MVA'))    # 10.0
print(network.base_frequency)          # 60.0 rotPers
print(get_line_code(line).calculatedFrequency)   # 60.0 rotPers

network.base_power and network.base_frequency come from the file's BasePower and BaseFrequency objects. When a file has neither, cim-graph's own defaults are in their place: 100 MVA and 60 Hz. Declare both in a model where a per-unit value matters.

Which getter

To read Getter Reference
A line's sequence impedance, whole line or per length get_line_sequence_impedance, get_line_sequence_impedance_per_length Lines and wires
A line's phase matrix, its code, its geometry get_line_phase_impedance_matrix, get_line_code, get_line_geometry Lines and wires
A transformer's windings, mesh and core get_transformer_units, get_transformer_model Transformers
Tap changers and regulator control get_tap_steps, get_tap_ratio, get_tap_changer_control Transformers
A load's phases, response and schedule get_phase_loads, get_load_response, get_load_schedule Loads
A shunt's reactive power or admittance get_shunt_reactive_power, get_shunt_admittance Loads
A source, an inverter, a machine get_source, get_der_output, get_inverter_rating Sources and DER
A node's connection, phases, base voltage, limits, switch state get_terminal_nodes, get_conductor_phases, get_base_voltage, get_current_limits, get_switch_state Topology and state