Lines and wires¶
The getters for an ACLineSegment: its impedance, its geometry, its conductors and its ratings. They live in
getters/line_impedance.py, spacing.py, wire.py, current_limits.py, impedance_table.py and earth.py.
Conventions common to every getter are on the reference landing page.
| A line is... | CIM path | Read with |
|---|---|---|
| lumped | ACLineSegment.r/x/bch/gch (and r0/x0/b0ch/g0ch) |
get_line_sequence_impedance |
| a per-length sequence code | ACLineSegment.PerLengthImpedance or .WireConfiguration.PerLengthImpedance → PerLengthSequenceImpedance |
get_line_sequence_impedance_per_length, get_line_phase_impedance_matrix |
| a per-length matrix code | the same path → PerLengthPhaseImpedance → PhaseImpedanceData |
get_line_phase_impedance_matrix |
| geometry | ACLineSegment.WireConfiguration → WireSpacing (XYSpacing → XYConductorPosition, or ConductorDistanceSpacing → ConductorDistance) and WireSequence → WireSequenceConfiguration.WireInfo |
the spacing and wire getters |
The examples use the shapes in cimhub_core/src/cimhub_core/shapes/ and run from the repo root. This block is the
setup the later ones share.
from pathlib import Path
import cimprofiles.cim18.cim18v17 as cim
from cimtables import BusBranchModel, load_model
def by_mrid(network, cls, mrid):
return next(obj for obj in network.graph[cls].values() if obj.mRID == mrid)
SHAPES = Path("cimhub_core/src/cimhub_core/shapes")
bus_branch = load_model(SHAPES / "line_bus_branch.cimtbl", model_cls=BusBranchModel)
by_code = load_model(SHAPES / "line_by_impedance.cimtbl")
by_geometry = load_model(SHAPES / "line_by_wire_configuration.cimtbl")
lumped = by_mrid(bus_branch, cim.ACLineSegment, "ln_1_2_1") # r, x, bch in pu
matrix_line = by_mrid(by_code, cim.ACLineSegment, "ln_l1") # a template matrix code
sequence_line = by_mrid(by_code, cim.ACLineSegment, "ln_l2") # its own sequence code
geometry_line = by_mrid(by_geometry, cim.ACLineSegment, "ln_g1") # XYSpacing + conductors
Line impedance¶
Module cimhub_core.getters.line_impedance. A bus-branch format (RAW, MATPOWER) takes only sequence values, so the
sequence getters may reduce what CIM holds. A format with geometry (GLM, DSS) exports the geometry and never calls the
sequence getters on a line that has it.
ImpedanceSource¶
An IntEnum. Each SequenceImpedance carries the step it came from in source, and derive= takes the furthest
step the getter may go.
| Value | Step | Source | Assumption added |
|---|---|---|---|
LUMPED (1) |
1 | ACLineSegment.r/x/bch/gch and the zero-sequence set, as stored |
none |
PER_LENGTH_SEQ (2) |
2 | PerLengthSequenceImpedance, times length for whole-line values |
the line's length |
MATRIX_REDUCED (3) |
3 | PerLengthPhaseImpedance, Kron-reduced if it has neutral conductors, then reduced to sequence values |
a transposed line; neutrals grounded at both ends. A conductor other than A, B, C and N raises |
GEOMETRY (4) |
4 | the WireConfiguration's spacing and wires through line constants | not built: a line with geometry and no lumped values raises NotImplementedError at derive=GEOMETRY |
The resolution order is the caller's, not a hidden fallback chain:
derive=caps the step. The defaultImpedanceSource.LUMPEDreads stored lumped values only and raises when they are absent.- When the line has lumped values, the per-length source is read only to check them. It is read at most to
MATRIX_REDUCED(geometry is never reached), and not at all when the line has nolength: the lumped values are then returned as they stand, instead of raising. - When the lumped values and a per-length source are both read, they must agree to a relative tolerance of
DISAGREEMENT_REL_TOL(1e-6) on every value both set, and the lumped values win. A difference raises. - No spoke passes
derive=yet;cimhub_rawandcimhub_opendsscallget_line_sequence_impedancewith the default.
SequenceImpedance¶
Returned by the sequence getters.
| Field | Meaning | Unit |
|---|---|---|
r, x |
positive-sequence series resistance and reactance; always set | impedance unit |
b, g |
positive-sequence shunt susceptance and conductance; None when unset |
admittance unit |
r0, x0 |
zero-sequence series values; None when unset |
impedance unit |
b0, g0 |
zero-sequence shunt values; None when unset |
admittance unit |
source |
the ImpedanceSource step that gave these values |
The whole-line getter returns whole-line values; the per-length getter returns values per unit length, in the units you name.
get_line_sequence_impedance¶
get_line_sequence_impedance(line, unit="ohm", admittance_unit=None, *, base_power=None,
derive=ImpedanceSource.LUMPED) -> SequenceImpedance
The whole line's sequence values.
| Parameter | Meaning |
|---|---|
line |
an ACLineSegment |
unit |
'ohm' or 'pu'. Anything else raises ValueError: unit must be one of ['ohm', 'pu'], not ... |
admittance_unit |
b and g: with 'ohm' any siemens unit ('S' by default; DSS asks 'nS'), with 'pu' only 'pu' (the default) |
base_power |
the power base for 'pu', normally network.base_power. The voltage base is the line's BaseVoltage; the conversion is cimtables.impedance.z_base. Required for 'pu' |
derive |
the furthest ImpedanceSource step to take |
It reads the lumped values first. When derive allows, it also reads the per-length source (the line's
get_line_code) and multiplies by the line's length. It raises ValueError when:
- nothing within
derivegives r and x (the message lists whether lumped r/x are set, thePerLengthImpedanceclass and whether there is geometry); - only one of lumped
randxis set; - the line has no lumped values, a per-length source gives them and the line has no
length(a per-length impedance needs the line's length); - two sources disagree beyond the tolerance.
It raises NotImplementedError (not ValueError) only when the line has no lumped values and derive reaches
GEOMETRY on a line with geometry. A line with lumped values and geometry returns the lumped values.
from cimhub_core.getters.line_impedance import ImpedanceSource, get_line_sequence_impedance
z = get_line_sequence_impedance(lumped, "pu", base_power=bus_branch.base_power)
print(z.r, z.x, z.b, z.g, z.source.name)
# 0.0194 0.0592 0.0528 None LUMPED
# the same line in ohm and siemens, on the line's BaseVoltage (115 kV) and the model's 100 MVA
z = get_line_sequence_impedance(lumped, "ohm")
print(round(z.r, 3), round(z.x, 3), z.source.name)
# 2.566 7.829 LUMPED
# a line with only a per-length code: the default derive raises, derive=PER_LENGTH_SEQ multiplies by the length
try:
get_line_sequence_impedance(sequence_line)
except ValueError as error:
print(error)
# ACLineSegment 'ln_l2': no sequence impedance within derive=LUMPED (lumped r/x: unset, PerLengthImpedance: PerLengthSequenceImpedance, geometry: none)
z = get_line_sequence_impedance(sequence_line, derive=ImpedanceSource.PER_LENGTH_SEQ)
print(round(z.r, 4), round(z.x, 4), round(z.r0, 4), z.source.name)
# 0.0532 0.065 0.0897 PER_LENGTH_SEQ
Called by cimhub_opendss and cimhub_raw.
get_line_sequence_impedance_per_length¶
get_line_sequence_impedance_per_length(line, impedance_unit="ohm/m", admittance_unit="S/m", *,
derive=ImpedanceSource.PER_LENGTH_SEQ) -> SequenceImpedance
The line's per-length sequence values, from its PerLengthImpedance (steps 2 and 3). The lumped values are whole-line
and never read. derive below PER_LENGTH_SEQ raises. Raises ValueError when nothing within derive gives r and x.
source is PER_LENGTH_SEQ, or MATRIX_REDUCED for a matrix code.
from cimhub_core.getters.line_impedance import get_line_sequence_impedance_per_length
z = get_line_sequence_impedance_per_length(sequence_line, "ohm/km", "nS/km")
print(z.r, z.x, round(z.b, 2), z.source.name)
# 0.3489 0.426198 3932.35 PER_LENGTH_SEQ
Called by cimhub_gdm.
get_line_phase_impedance_matrix¶
get_line_phase_impedance_matrix(line, impedance_unit="ohm/m", admittance_unit="S/m", *,
expand_sequence=False) -> PhaseMatrix
The line's per-length phase matrix in conductor order, neutrals and s1/s2 included as stored. A
PerLengthPhaseImpedance is read directly. A PerLengthSequenceImpedance becomes a matrix only with
expand_sequence=True, by cimhub_core.derived.sequence (see Derived values): one phase is Z1 alone;
more are self (2 Z1 + Z0) / 3 and mutual (Z0 - Z1) / 3. Raises ValueError when:
- the code is a sequence code and
expand_sequenceis false ("pass expand_sequence=True"); - the line has geometry and no
PerLengthImpedance(export the geometry instead); - the line has no
PerLengthImpedanceat all; - the code's entries are not the lower triangle of the line's conductors;
rorxis unset, orb/gis set on some entries and not others.
PhaseMatrix fields:
| Field | Meaning |
|---|---|
phases |
the conductors, as SinglePhaseKind, in get_conductor_phases order |
r, x |
{(row, column): value}, lower triangle, 1-based, per length |
b, g |
the same for shunt admittance; None when unset |
source |
MatrixSource.PHASE_CODE (read as stored) or MatrixSource.SEQUENCE_EXPANDED (a sequence code expanded, assuming a transposed line) |
from cimhub_core.getters.line_impedance import get_line_phase_impedance_matrix
m = get_line_phase_impedance_matrix(matrix_line, "ohm/mi", "nS/mi")
print([phase.value for phase in m.phases], m.source.name)
print({key: round(value, 4) for key, value in m.r.items()})
# ['C', 'B'] PHASE_CODE
# {(1, 1): 1.3238, (2, 1): 0.2066, (2, 2): 1.3294}
m = get_line_phase_impedance_matrix(sequence_line, "ohm/km", "nS/km", expand_sequence=True)
print(m.source.name, round(m.r[1, 1], 4), round(m.r[2, 1], 4))
# SEQUENCE_EXPANDED 0.4289 0.08
Called by cimhub_gdm and cimhub_gridlabd (only where CIM has no geometry).
get_phase_impedance_code, get_sequence_impedance_code¶
get_phase_impedance_code(code, impedance_unit="ohm/m", admittance_unit="S/m") -> CodeMatrix
get_sequence_impedance_code(code, impedance_unit="ohm/m", admittance_unit="S/m") -> SequenceImpedance
A PerLengthPhaseImpedance or PerLengthSequenceImpedance read on its own, whether or not a line uses it, for
exporters that write a catalog of codes. A code of the wrong class raises ValueError: ... is not a
PerLengthPhaseImpedance. A phase code needs conductorCount and entries that are exactly the lower triangle of that
many conductors. A sequence code needs r and x; its source is PER_LENGTH_SEQ.
CodeMatrix fields: conductor_count (int), and r, x, b, g as in PhaseMatrix (b and g are None when
unset), keyed by the code's own 1-based rows.
from cimhub_core.getters.line_impedance import get_line_code, get_phase_impedance_code
code = get_line_code(matrix_line)
print(type(code).__name__, get_phase_impedance_code(code, "ohm/mi", "nS/mi").conductor_count)
# PerLengthPhaseImpedance 2
Both are called by cimhub_opendss.
get_line_code, get_line_geometry¶
get_line_code(line) -> cim.PerLengthImpedance | None
get_line_geometry(line) -> cim.WireConfiguration | None
get_line_code returns the line's own ACLineSegment.PerLengthImpedance, else its WireConfiguration's (a template
LineCode, or the matrix equivalent of a configuration). When both are set and differ it raises. get_line_geometry
returns the WireConfiguration only when it names a WireSpacing: a configuration that holds only a
PerLengthImpedance is a template code, not geometry, and returns None. Use these two instead of testing
line.PerLengthImpedance or line.WireConfiguration is not None.
from cimhub_core.getters.line_impedance import get_line_geometry
print(get_line_geometry(matrix_line), get_line_geometry(geometry_line).mRID)
# None wc_601
print(get_line_code(geometry_line))
# None
Both are called by cimhub_gdm, cimhub_gridlabd and cimhub_opendss.
Spacing¶
Module cimhub_core.getters.spacing. A spacing is read from either CIM form, and conductors are keyed by sequence
number, which matches ACLineSegmentPhase.sequenceNumber on a line that uses it. The spacing names no phases.
| Form | What it holds | Positions |
|---|---|---|
XYSpacing |
XYConductorPosition.xCoord/yCoord, in the spacing's frame. A ConductorGroupPosition (a bundle, such as a triplex) is expanded into its SubConductorPositions: a RegularBundlePosition's at the corners of its polygon, any other group's at their own coordinates, both rotated by orientation |
as stored |
ConductorDistanceSpacing |
ConductorDistance.distance between sequenceNumber1 and sequenceNumber2, and each conductor's height as its distance to a position of kind earth |
solved by cimhub_core.derived.spacing: first conductor at x = 0, mirror images to the right |
An XYSpacing's origin may be ground, the top of the pole or the centre of the crossarm. The line's ySpacingOffset
lifts it to a height above ground, so one crossarm design serves poles of any height. There is no default height: a
missing coordinate, distance or height raises. circuitNumber is not read, and two conductors on one sequence number
(parallel conductors) raise.
Two NamedTuples:
| NamedTuple | Fields |
|---|---|
ConductorXY |
sequence_number (int), kind (ConductorPositionKind or None), x, y (length unit; y is up) |
StoredDistances |
kinds ({sequence number: kind}), distances ({(i, j): value}, i < j), heights ({sequence number: y}: an XYSpacing's y in its own frame, or the stored earth distance) |
get_line_conductor_xy¶
The line's conductors with y above ground: the positions of its ACLineSegmentPhases' sequence numbers, phase
conductors first and then neutrals, each in sequence-number order, raised by ySpacingOffset (unset means the origin
is ground). A line without ACLineSegmentPhases takes every position. The spacing is the line's WireSpacing, or its
WireConfiguration's; both set must be the same spacing. Raises ValueError when the line has no spacing, a phase has no
sequenceNumber, a phase's number has no conductor in the spacing, or a ConductorDistanceSpacing (which already
holds heights above ground) meets a ySpacingOffset.
from cimhub_core.getters.spacing import get_line_conductor_xy
for conductor in get_line_conductor_xy(geometry_line, "ft"):
print(conductor.sequence_number, conductor.kind.value, round(conductor.x, 2), round(conductor.y, 2))
# 1 phase 0.0 28.0
# 2 phase 2.5 28.0
# 3 phase 7.0 28.0
# 4 neutral 4.0 24.0
Called by cimhub_gdm and cimhub_opendss.
get_spacing_xy, get_stored_distances¶
get_spacing_xy(spacing, unit="m") -> tuple[ConductorXY, ...]
get_stored_distances(spacing, unit="m") -> StoredDistances
get_spacing_xy: the spacing's conductors in sequence-number order, in the spacing's own frame (no offset). AConductorDistanceSpacingneeds a height for every conductor and distances that determine one geometry; a distance shorter than the height difference, or a stored distance that disagrees with the solved positions by more than a relative 1e-4 (DISTANCE_REL_TOL), raises.get_stored_distances: what the spacing holds, as it holds it: anXYSpacing's every pair and its y, aConductorDistanceSpacing's stored rows only. A spacing with noConductorDistancerows at all (GLM's all-zero spacing, "no coupling") returns empty dictionaries rather than raising.
Any other WireSpacing class raises ValueError: ... has no conductor positions; only XYSpacing and
ConductorDistanceSpacing are read.
from cimhub_core.getters.spacing import get_spacing_xy, get_stored_distances
distance_spacing = load_model("cimhub_gridlabd/tests/atoms/catalog/catalog.line_spacing.cimtbl")
spacing = by_mrid(distance_spacing, cim.ConductorDistanceSpacing, "spc_spc_601_ABCN")
print([(c.sequence_number, round(c.x, 2), round(c.y, 2)) for c in get_spacing_xy(spacing, "ft")])
# [(1, 0.0, 28.0), (2, 2.5, 28.0), (3, 7.0, 28.0), (4, 4.0, 24.0)]
print(round(get_stored_distances(spacing, "ft").distances[1, 4], 4))
# 5.6569
# a spacing with a pair and no heights: GLM's "AN only" form
no_heights = by_mrid(distance_spacing, cim.ConductorDistanceSpacing, "spc_line_spacing:10")
print(get_stored_distances(no_heights, "in").distances, get_stored_distances(no_heights, "in").heights)
# {(1, 2): 84.0} {}
try:
get_spacing_xy(no_heights)
except ValueError as error:
print(error)
# ConductorDistanceSpacing 'spc_line_spacing:10': conductors [1, 2] have no height (a ConductorDistance to a position of kind earth)
get_stored_distances is called by cimhub_gridlabd, which writes any spacing (XY or distances) as a
line_spacing through it; get_spacing_xy by cimhub_opendss.
Wires¶
Module cimhub_core.getters.wire. The conductor catalog entries, and the conductors a configuration or line names.
Four WireInfo kinds are read (WIRE_KINDS): OverheadWireInfo, a plain CableInfo,
ConcentricNeutralCableInfo and TapeShieldCableInfo.
get_wire_info¶
Every value as stored, in the units you name; None is unset. rAC25 and rAC50 are read. A set rAC75 raises,
because no producer writes one. A ratedCurrent and a normal limit in the wire's own
AssetInfo.OperationalLimitSet that are both set must agree. A class other than the four raises.
WireValues fields:
| Field | Meaning | Unit |
|---|---|---|
kind |
the wire's class, one of WIRE_KINDS |
|
r_dc20, r_ac25, r_ac50 |
resistance at 20 C dc, 25 C ac, 50 C ac | resistance_unit (per length) |
gmr, radius |
geometric mean radius and conductor radius | length_unit |
rated_current |
ratedCurrent |
current_unit |
limits |
the wire's own limits, a CurrentLimits |
current_unit |
cable |
a CableValues, None on an OverheadWireInfo |
CableValues fields: insulation_thickness, diameter_over_insulation, diameter_over_jacket,
diameter_over_screen (length unit). Five are None unless the wire is a ConcentricNeutralCableInfo:
diameter_over_neutral, neutral_strand_radius and neutral_strand_gmr (length unit), neutral_strand_count (an
int) and neutral_strand_r_dc20 (resistance unit). Two are None unless it is a TapeShieldCableInfo:
tape_thickness (length unit) and tape_lap (percent).
from cimhub_core.getters.wire import get_wire_info
wire = by_mrid(by_geometry, cim.OverheadWireInfo, "wire_acsr_556_5")
values = get_wire_info(wire, "in", "ohm/mi")
print(values.kind.__name__, round(values.r_dc20, 3), round(values.gmr, 4), round(values.radius, 4), values.rated_current)
# OverheadWireInfo 0.186 0.3732 0.4635 730.0
cables = load_model("cimhub_gridlabd/tests/atoms/catalog/catalog.underground_line_conductor.cimtbl")
cable = get_wire_info(by_mrid(cables, cim.ConcentricNeutralCableInfo, "ugc_cncab_cn_250"), "in", "ohm/mi").cable
print(cable.neutral_strand_count, cable.tape_thickness)
# 13 None
Called by cimhub_gdm, cimhub_gridlabd and cimhub_opendss.
get_configuration_wires, get_line_phase_wires¶
get_configuration_wires(configuration) -> tuple[tuple[int, cim.WireInfo], ...]
get_line_phase_wires(line) -> tuple[tuple[int, cim.WireInfo], ...]
(sequenceNumber, WireInfo) pairs in sequence-number order. get_configuration_wires reads a WireConfiguration's
WireSequenceConfigurations. get_line_phase_wires reads a line's own ACLineSegmentPhase.WireInfo, and returns an
empty tuple when no phase names a conductor. Both raise on an unset or repeated sequence number. A configuration's
conductor without a WireInfo raises, and so does a phase without one beside a phase that has one.
from cimhub_core.getters.wire import get_configuration_wires, get_line_phase_wires
wires = get_configuration_wires(get_line_geometry(geometry_line))
print([(number, wire.mRID) for number, wire in wires])
# [(1, 'wire_acsr_556_5'), (2, 'wire_acsr_556_5'), (3, 'wire_acsr_556_5'), (4, 'wire_acsr_4/0')]
print(get_line_phase_wires(geometry_line))
# ()
get_configuration_wires is called by cimhub_gdm, cimhub_gridlabd and cimhub_opendss; get_line_phase_wires
by cimhub_opendss.
Current limits¶
Module cimhub_core.getters.current_limits.
get_current_limits(equipment, unit="A", *, season=None) -> CurrentLimits
get_asset_info_current_limits(info, unit="A", *, season=None) -> CurrentLimits
equipment_limit_sets(equipment) -> list[OperationalLimitSet]
agreed_limit(owner, what, found) -> float | None
CIM hangs an OperationalLimitSet on the rated equipment, on its Terminals, or on both. get_current_limits reads
every set on the equipment and its terminals (equipment_limit_sets lists them, each once). Each CurrentLimit is
classified by its OperationalLimitType.durationKind (normal, shortTerm, emergency) and valued by
normalValue. A type's season (CalendarSeasonKind, a GridAPPS-D extension) makes the limit seasonal; a type with
no season holds all year.
season=Nonereads the all-year limits only.- With a season, each kind is that season's limit, or the all-year one where the season has none.
- Limits of one kind and season must agree (
agreed_limit; differing values raise).agreed_limit(owner, what, found)takesfound, a list of(CurrentLimit, value)pairs, and returns the one value, orNonefor an empty list. - Raises when a
CurrentLimithas noOperationalLimitType, a type has nodurationKindor an unsupported one, or a limit has nonormalValue.
CurrentLimits fields: normal, short_term, emergency, each a float in unit or None when the equipment has
no limit of that kind.
get_asset_info_current_limits reads a catalog entry's limits, from AssetInfo.OperationalLimitSet. An equipment does
not inherit them; get_wire_info calls it for a wire's limits.
from cimhub_core.getters.current_limits import get_current_limits
print(get_current_limits(matrix_line))
# CurrentLimits(normal=340.0, short_term=None, emergency=600.0)
print(get_current_limits(matrix_line, "kA"))
# CurrentLimits(normal=0.34, short_term=None, emergency=0.6)
get_current_limits is called by cimhub_gdm, cimhub_gridlabd and cimhub_opendss.
Impedance tap changer table¶
Module cimhub_core.getters.impedance_table.
The points of an ImpedanceTapChangerTable, in its list order. Which of step, ratio and angle a consumer looks a
point up by is the consumer's, so each is returned as stored. A table with no points raises.
ImpedanceTablePoint fields:
| Field | Meaning | Unit |
|---|---|---|
step |
tap position, or None |
|
ratio |
turns ratio, or None |
pu of the end's ratedU |
angle |
phase angle, or None |
angle_unit, CIM's sign |
r |
(rEnd1, rEnd2, rEnd3), each None when unset |
percent of the end's nominal r |
x |
(xEnd1, xEnd2, xEnd3), each None when unset |
percent of the end's nominal x |
from cimhub_core.getters.impedance_table import get_impedance_table
table = cim.ImpedanceTapChangerTable(mRID="ict_1")
point = cim.ImpedanceTapChangerTablePoint(step=3, ratio=0.95, angle=cim.AngleDegrees(30.0),
rEnd1=cim.PerCent(20.0), xEnd1=cim.PerCent(20.0))
point.ImpedanceTapChangerTable = table
table.ImpedanceTapChangerTablePoint.append(point)
print(get_impedance_table(table))
# (ImpedanceTablePoint(step=3, ratio=0.95, angle=30.0, r=(20.0, None, None), x=(20.0, None, None)),)
Called by cimhub_raw.
Earth¶
Module cimhub_core.getters.earth. A geometry is only an impedance once an earth model and a resistivity are chosen.
cim18v17 holds them on EarthResistivity, shared by the configurations computed over one earth.
get_earth_resistivity reads the configuration's EarthResistivity, and returns None when it names none.
get_network_earth is for a line with a direct WireSpacing, which cim18v17 cannot associate with an
EarthResistivity: it returns the network's one, and raises when the network has none or several.
EarthData fields:
| Field | Meaning | Unit |
|---|---|---|
model |
EarthModelKind (for example carson, deri), or None |
|
rho |
resistivity | ohm-m (typed Resistance in the profile, so it is read in ohm and stands for ohm-m) |
earth_return_gmr |
Carson earth-return GMR | m |
from cimhub_core.getters.earth import get_earth_resistivity, get_network_earth
earth = get_earth_resistivity(get_line_geometry(geometry_line))
print(earth.model.value, earth.rho, earth.earth_return_gmr)
# carson 100.0 None
print(get_network_earth(by_geometry) == earth)
# True
Both are called by cimhub_opendss.