Transformers and regulators

The getters for a transformer's windings, impedance and core, for its tap changers, and for the controls that drive them. They live in getters/transformer.py, tap_changer.py and control.py. Conventions common to every getter are on the reference landing page.

The examples use the shapes in cimhub_core/src/cimhub_core/shapes/ and run from the repo root. This block is the setup the later ones share.

from pathlib import Path

import cimprofiles.cim18.cim18v17 as cim
from cimtables import load_model


def by_mrid(network, cls, mrid):
    return next(obj for obj in network.graph[cls].values() if obj.mRID == mrid)


SHAPES = Path("cimhub_core/src/cimhub_core/shapes")
by_ends = load_model(SHAPES / "transformer_by_ends.cimtbl")
by_phase_ends = load_model(SHAPES / "transformer_by_phase_ends.cimtbl")
by_template = load_model(SHAPES / "transformer_by_template.cimtbl")
by_tank_impedance = load_model(SHAPES / "transformer_by_tank_impedance.cimtbl")
regulator = load_model(SHAPES / "regulator.cimtbl")


def summarize(model):
    print(model.form.name, "base_power", model.base_power)
    for winding in model.windings:
        phases = "".join(phase.value for phase in winding.phases)
        print(" ", winding.number, phases, winding.rated_u, winding.rated_s, winding.base_u, winding.r)  # number, phases, ratedU, ratedS, baseU, r
    print("  mesh", {pair: (z.r, round(z.x, 3)) for pair, z in model.mesh.items()})
    print("  core", model.core)

The transformer model

Module cimhub_core.getters.transformer. One getter reads the windings, the mesh impedance and the core of a transformer as one model, whatever CIM form holds them.

get_transformer_units

get_transformer_units(transformer) -> tuple

The units get_transformer_model reads: a PowerTransformer's TransformerTanks when it has any, else the transformer itself (a PowerTransformer without tanks, or an AutoTransformer). A PowerTransformer that has tanks passed straight to get_transformer_model raises: read each unit this returns.

get_transformer_model

get_transformer_model(unit, impedance_unit="percent", *, base_power: float | None = None, voltage_unit="V",
                      power_unit="VA") -> TransformerModel
Parameter Meaning
unit a TransformerTank, a PowerTransformer without tanks, or an AutoTransformer
impedance_unit 'percent' or 'pu'; anything else raises ValueError: impedance_unit must be one of ['percent', 'pu'], not ...
base_power the power, in power_unit, every impedance and admittance is put on (RAW's MBASE). Default: winding 1's ratedS
voltage_unit unit of rated_u, base_u
power_unit unit of rated_s, base_s and TransformerModel.base_power

It raises ValueError when a form is ambiguous, when a rating a value needs is unset, or when two places that hold the same value disagree.

from cimhub_core.getters.transformer import get_transformer_model, get_transformer_units

substation = by_mrid(by_ends, cim.PowerTransformer, "xf_sub")
[unit] = get_transformer_units(substation)  # no tanks: the transformer itself
summarize(get_transformer_model(unit, voltage_unit="kV", power_unit="kVA"))
# BY_ENDS base_power 5000.0
#   1 ABC 115.0 5000.0 None 0.5
#   2 ABCN 4.16 5000.0 None 0.5
#   mesh {(1, 2): (None, 8.0)}
#   core CoreAdmittance(g=None, b=None)

Called by cimhub_gdm, cimhub_gridlabd, cimhub_opendss and cimhub_raw.

The base every value is on

Every impedance and admittance comes out in percent or pu on one power base, and the voltage is always the From winding's own (ratedU, or a coil's baseU).

Case How the value is read
base_power given, and the form is BY_ENDS or AUTO Each ohm and siemens is read on that power directly (get_qty(power_base=)). The ends need no ratedS (a three-winding unit whose ends have none still reads)
otherwise CIM's value is read as a percent on its From winding's own baseU²/baseS, then moved to the declared base by the power only: z × S_new / S_old and y × S_old / S_new
no base_power the base is winding 1's ratedS (the percent convention of DSS and GLM)

A winding's baseS is per phase, so the whole-unit power of a coil is winding 1's ratedS scaled by the two baseS. A set ratedU, ratedS, baseU or baseS of 0 or less raises ValueError, since every percent is on one. The one unit that may leave the base unset is an ideal AutoTransformer (no mesh impedance, no ratedS): its base_power is None.

model = get_transformer_model(unit, "pu", base_power=10, voltage_unit="kV", power_unit="MVA")
print(model.base_power, model.windings[0].r, model.mesh[1, 2].x)
# 10.0 0.01 0.16

The ends' 0.5 % r and 8 % x are on 5 MVA, so on 10 MVA they are 1 % and 16 %, written as 0.01 and 0.16 pu.

TransformerModel and its parts

TransformerModel fields:

Field Meaning
form the TransformerForm that held the values
windings a tuple of Winding, in winding order
mesh {(i, j): MeshImpedance} with i < j winding numbers
core the magnetizing branch, a CoreAdmittance
base_power what every percent or pu is on, in power_unit; None on an unrated ideal AutoTransformer

Winding fields. Windings are numbered from 1 in end-number order; a coil of a phase-ends or lugs form by its lowest phase end sequenceNumber. Two windings in the same place raise.

Field Meaning Unit
number winding number
end the instance end it lands on: a PowerTransformerEnd or AutoTransformerEnd
phases a coil's two phase ends, else the end's terminal phases (SinglePhaseKind)
connection WindingConnection, or None
grounded bool or None
rground, xground grounding impedance, or None ohm
rated_u ratedU; an AutoTransformerEnd has none voltage_unit
rated_s ratedS, or None when unset. Winding 1's is required, except on an end form with a declared base_power and on an ideal AutoTransformer power_unit
base_u the coil voltage. A PowerTransformerEnd has no baseU, so for an end of two conductors it is derived from ratedU, the phase-to-phase nameplate: as is between two phases, over √3 from a phase to the neutral. None for an end of more conductors voltage_unit
base_s per-phase power; a PowerTransformerEnd has none power_unit
r the winding's resistance, on the model's base percent or pu
phase_shift the instance PowerTransformerEnd's fixed phaseShift deg
r_dc a TransformerWinding's rDC (a tank's or a template's winding), or None; an end has none ohm

MeshImpedance(r, x) is the impedance between two windings on the model's base; x is always set, r may be None. CoreAdmittance(g, b) is the magnetizing branch on the model's base, None where unset.

TransformerForm

TransformerForm is an Enum. The getter picks the form from what the unit holds and raises when the unit mixes them.

Form The unit holds Windings come from Mesh Core
BY_ENDS a PowerTransformer without tanks PowerTransformerEnd ratings and r. A single-phase coil takes its voltage from ratedU (see base_u) TransformerMeshImpedance between ends, or each end's star x summed by pair (two windings: an unset end x counts as 0, CIM's two-winding rule; three or more: any unset end x raises); both together raise g and b on the one end that holds them (zeros on several ends are one zero core; a non-zero core on several raises)
AUTO an AutoTransformer AutoTransformerEnd (baseU, ratedS) a mesh between ends none: CoreAdmittance(None, None)
BY_PHASE_ENDS a TransformerTank with its own TransformerWindings and no TankConfiguration each winding is a coil between two TransformerPhaseEnds, matched to the PowerTransformerEnd by endNumber a mesh between windings the tank's noLoadLoss and percentMagnetizingCurrent
BY_TANK_ENDS a tank with a TankConfiguration whose windings start at a TransformerTankEnd one winding per TransformerTankEnd; template end n is instance end n. Connection and grounding set on both must agree, up to the grounding (Y and Yn): the instance's wins. Phases are the instance end's TransformerPhaseEnds in sequenceNumber order, else its terminal phases the configuration's mesh the tank's or configuration's noLoadLoss and percentMagnetizingCurrent
BY_LUGS a tank with a TankConfiguration whose windings run lug to lug a lug's sequenceNumber names the instance TransformerPhaseEnd it lands on (a centre tap). A bank of template tanks is always lugged, every can the configuration's mesh as BY_TANK_ENDS
BY_TANK_IMPEDANCE two PowerTransformerEnds and one tank with percentImpedance (and loadLoss), nothing else the two ends; a centre-tap end becomes two halves split from the nameplate (below) noLoadLoss and percentMagnetizingCurrent

Either template form (BY_TANK_ENDS, BY_LUGS) may hold its impedance as the configuration's percentImpedance and loadLoss instead of a winding r and a mesh. It is read as the nameplate form below when no winding has an r or a mesh. When one does, the percentImpedance beside it is the nameplate's figure and is not read.

Nameplate impedance (BY_TANK_IMPEDANCE)

The magnitude |z| is percentImpedance on the can's kVA: winding 1's ratedS for a single tank (its baseS, when set, must equal that ratedS), or the tank's own baseS for a can of a bank. Then:

r = loadLoss / ratedS × 100        (0 when loadLoss is unset)
x = sqrt(z² - r²)                  (loadLoss above the impedance raises)
Case Winding r (share of r) Mesh x (share of x)
two windings (TWO_WINDING_SPLIT) 0.5, 0.5 (1, 2): 1.0
centre tap, three windings (CENTER_TAP_SPLIT) 0.5, 1.0, 1.0 (1, 2): 1.2, (1, 3): 1.2, (2, 3): 0.8

A centre tap is an end on s1, s2 and N with connectionKind I: two halves, s1 to N and N to s2, each at half the end's ratedU and ratedS. The split is Hopkinson's rule for an interlaced secondary. A bank of cans (one tank per can, each with its own baseS) puts each can's primary on one phase of end 1, and its secondary on a wye end's phase or across two phases of a delta end; the cans' baseS must add up to end 1's ratedS. A tank whose end already holds r, x, g, b or a mesh raises: one value would have two homes.

Examples by form

unit = get_transformer_units(by_mrid(by_phase_ends, cim.PowerTransformer, "xf_t3"))[0]
summarize(get_transformer_model(unit, voltage_unit="V", power_unit="VA"))
# BY_PHASE_ENDS base_power 5000.0
#   1 AB 4160.0 5000.0 4160.0 0.6
#   2 s1N 240.0 2500.0 120.0 1.2
#   3 Ns2 240.0 2500.0 120.0 1.2
#   mesh {(1, 2): (None, 2.04), (1, 3): (None, 2.04), (2, 3): (None, 1.36)}
#   core CoreAdmittance(g=0.2, b=0.5)

A template form:

unit = get_transformer_units(by_mrid(by_template, cim.PowerTransformer, "xf_t1"))[0]
model = get_transformer_model(unit, voltage_unit="V", power_unit="VA")
print(model.form.name, model.mesh[1, 2], [round(w.base_u) for w in model.windings])
# BY_TANK_ENDS MeshImpedance(r=1.1, x=2.0) [2400, 277]

unit = get_transformer_units(by_mrid(by_template, cim.PowerTransformer, "xf_t2"))[0]
print(get_transformer_model(unit).form.name)
# BY_LUGS

A nameplate form with a centre tap:

unit = get_transformer_units(by_mrid(by_tank_impedance, cim.PowerTransformer, "xf_t6"))[0]
model = get_transformer_model(unit, voltage_unit="V", power_unit="VA")
print(model.form.name, [(w.number, "".join(p.value for p in w.phases), w.r) for w in model.windings])
print({pair: round(z.x, 3) for pair, z in model.mesh.items()})
# BY_TANK_IMPEDANCE [(1, 'BN', 0.248), (2, 's1N', 0.496), (3, 'Ns2', 0.496)]
# {(1, 2): 2.695, (1, 3): 2.695, (2, 3): 1.797}

The get_transformer_model raises that you will meet most often:

Message starts Cause
PowerTransformer '...': has tanks; read each unit get_transformer_units gives a transformer with tanks was passed whole
TransformerTank '...': has its own TransformerWindings and a TankConfiguration two homes for the windings
... a bank mixes tanks by percentImpedance with ... tanks of one transformer use different forms
... two windings have the same place duplicate end numbers or phase-end sequence numbers
... both a star impedance (PowerTransformerEnd.x) and a mesh impedance two homes for the impedance
... ratedS is unset winding 1 has no rating and the base is not base_power on an end form
... the star x of winding(s) [...] is unset three or more windings, and an end has no x
... more than one end holds the core admittance a non-zero g or b on two ends

Tap changers

Module cimhub_core.getters.tap_changer. TapChanger.step is a tap position, never a turns ratio, and so are normalStep, lowStep, highStep and neutralStep. The ratio at a position is

ratio   = 1 + (position - neutralStep) × stepVoltageIncrement / 100
voltage = neutralU + (position - neutralStep) × stepVoltageIncrement / 100 × ratedU

where ratedU is the tap's TransformerEnd and stepVoltageIncrement is a percent of it. There is no default increment: an unset one raises, except on a fixed tap (lowStep = highStep), which has no step to increment. A fixed tap's increment is None, its ratio is 1 and its voltage is its neutralU.

get_tap_steps, get_phase_tap_steps

get_tap_steps(tap, voltage_unit="V") -> TapSteps
get_phase_tap_steps(tap, angle_unit="deg") -> PhaseTapSteps

TapSteps fields:

Field Meaning Unit
low, high, neutral lowStep, highStep, neutralStep; required position
normal normalStep, or None position
step the actual position, or None position
increment stepVoltageIncrement; required unless the tap is fixed, then None percent per step
neutral_u neutralU, or None voltage_unit

PhaseTapSteps (for a PhaseTapChangerLinear) has low, high, neutral, normal, step as above and a required increment, the stepPhaseShiftIncrement per step in angle_unit, in CIM's sign (from the terminal into the transformer).

from cimhub_core.getters.tap_changer import get_phase_tap_steps, get_tap_ratio, get_tap_steps, get_tap_voltage

tap = by_mrid(regulator, cim.RatioTapChanger, "xf_reg1_tap")
print(get_tap_steps(tap))
# TapSteps(low=-16, high=16, neutral=0, normal=0, step=10.0, increment=0.625, neutral_u=2400.0)

phase_tap = cim.PhaseTapChangerLinear(mRID="pt", lowStep=1, highStep=33, neutralStep=17, step=20.0,
                                      stepPhaseShiftIncrement=cim.AngleDegrees(-1.875))
print(get_phase_tap_steps(phase_tap))
# PhaseTapSteps(low=1, high=33, neutral=17, normal=None, step=20.0, increment=-1.875)

get_tap_steps is called by all four spokes; get_phase_tap_steps by cimhub_raw.

get_tap_ratio, get_tap_voltage

get_tap_ratio(tap, *, which) -> float
get_tap_voltage(tap, *, which, voltage_unit="V") -> float

which is 'actual' (step), 'normal', 'low' or 'high', and has no default, because the actual and normal positions differ in any model that is not as built. Anything else raises ValueError: which must be one of ['actual', 'high', 'low', 'normal'], not .... An unset position raises. get_tap_voltage also requires neutralU, and on a tap that moves requires the tap's TransformerEnd and its ratedU.

for which in ("actual", "normal", "low", "high"):
    print(which, get_tap_ratio(tap, which=which), get_tap_voltage(tap, which=which))
# actual 1.0625 2550.0
# normal 1.0 2400.0
# low 0.9 2160.0
# high 1.1 2640.0

get_tap_ratio is called by cimhub_gdm, cimhub_gridlabd and cimhub_opendss; get_tap_voltage by cimhub_raw.

Controls

Module cimhub_core.getters.control. A RegulatingControl's target is a plain float in the primary units of its mode (V, A, W, VAr), times targetValueUnitMultiplier when set.

Mode Quantity SI unit
voltage Voltage V
currentFlow CurrentFlow A
activePower ActivePower W
reactivePower ReactivePower VAr

A mode with no quantity here (powerFactor, timeScheduled, admittance, temperature) is returned as stored, and naming a unit or a multiplier for it raises.

get_regulating_control

get_regulating_control(control, unit=None) -> RegulatingSettings

The control's mode, targets in unit (default: its mode's SI unit), monitored terminal and phases. It raises when the mode is unset, when the control monitors no Terminal, or when targetValue is unset on a control that is not disabled. A disabled control (enabled false, such as a manual regulator) may leave targetValue unset; its target is then None.

RegulatingSettings fields:

Field Meaning Unit
mode RegulatingControlModeKind
unit what the targets are in; None for a mode returned as stored
target targetValue; None only on a disabled control unit
deadband targetDeadband (the full band width) unit
min_allowed, max_allowed minAllowedTargetValue, maxAllowedTargetValue unit
reverse_target, reverse_deadband the reverse-flow target and band unit
terminal the monitored Terminal
monitored_phases SinglePhaseKind tokens, or None when monitoredPhase is unset
enabled, discrete as stored, or None
pt_ratio, ct_ratio as stored on the control, or None

Called by cimhub_raw.

get_tap_changer_control

get_tap_changer_control(tap, *, unit=None, time_unit="s", voltage_unit="V", power_unit="W") -> TapChangerSettings

The tap changer's control settings. unit is the targets' unit as in get_regulating_control. ptRatio and ctRatio may sit on the TapChanger, its TapChangerControl, or both; both set must agree, or it raises.

TapChangerSettings fields:

Field Meaning Unit
control the TapChangerControl's RegulatingSettings with pt_ratio and ct_ratio agreed; None when the tap has no control
control_enabled, ltc controlEnabled, ltcFlag
ct_rating the tap's ctRating A
initial_delay, subsequent_delay the tap's delays time_unit
line_drop_compensation lineDropCompensation of the control
line_drop, reverse_line_drop LineDrop(r, x): lineDropR/X and reverseLineDropR/X, in primary ohms ohm
reversible, reverse_to_neutral the control's flags
reversing_delay reversingDelay time_unit
reversing_power_threshold reversingPowerThreshold power_unit
min_limit_u, max_limit_u minLimitVoltage, maxLimitVoltage voltage_unit
from cimhub_core.getters.control import get_tap_changer_control

settings = get_tap_changer_control(tap, unit="kV")
print(settings.control.target, settings.control.deadband, settings.control.unit)
print(settings.line_drop, settings.initial_delay, settings.ct_rating)
# 2.44 0.04 kV
# LineDrop(r=0.085714, x=0.257143) 15.0 700.0

Called by all four spokes.

get_equipment_control

get_equipment_control(equipment, *, unit=None, time_unit="s") -> EquipmentControl | None

The control of a regulated device (a shunt, a machine, an inverter), or None when it has none. EquipmentControl fields: control (a RegulatingSettings), control_enabled (RegulatingCondEq.controlEnabled) and delay (ShuntCompensator.aVRDelay in time_unit; None on other equipment). Called by cimhub_gdm, cimhub_gridlabd and cimhub_opendss.