Skip to content

GridLAB-D → .cimtbl mapping spec

Status: S0 (master) built 2026-11-09; each later section is written with its slice and approved before that slice's code. Plan: .development/GLM_REWRITE_PLAN.md. Contract and format: the cimtbl-import-contract, cimtbl-shapes and cimtbl-mapping-spec skills. Samples come from the vendored decks in tests/decks/ (origins in its README).

Artifact files and order

The master imports the parts in MAPPING_ORDER (importer/glm_to_cimtbl.py), which follows the plan's section 2. S0 has no parts; S1 adds bus.cimtbl and source.cimtbl; S2 the six catalog files; S3a the six line and switch files; S3b transformer_configuration.cimtbl (after the catalogs) and transformer.cimtbl (after the switches); S3c regulator.cimtbl (after the transformers; regulator_configuration has no file of its own); S4a the core zip_fractions.cimtbl (after source.cimtbl), then load.cimtbl, triplex_load.cimtbl, triplex_node.cimtbl and capacitor.cimtbl (after the regulators); S7 series_reactor.cimtbl (after the switches); S8 player.cimtbl (after the regulators, before the loads that name its groups); S9 schedule.cimtbl (after the players, before the loads).

master

Mapper: importer/glm_to_cimtbl.py map_master. Test: tests/test_glm_to_cimtbl.py; golden tests/goldens/IEEE13_cdpsm/IEEE13_cdpsm.cimtbl.

row from rule
Substation, Feeder substation= and feeder=, each the name the caller passes unless given (D7; the model's Model and file stem stay name) mRIDs sub_<substation>, fdr_<feeder>, source case
Update Table Terminal (last, after the Imports) every mapped link touching a swing bus NormalHeadFeeder = the feeder on that link's Terminal there: <mRID>_T1 for its from, _T2 for its to (a regulator: each unit's); a head on a link no mapper writes raises
BaseFrequency module powerflow { nominal_frequency ...; }, else #set powerflow::nominal_frequency=... else GridLAB-D's 60 Hz, listed as # defaulted
BaseVoltage the topology walk's distinct bus voltages (cimtopology.core), highest first nominal_kv rounding; mRIDs bv_12p47kv, bv_240v
comment every GLM type no mapper reads, with its count, including types the schema lacks (recorder) GLM-14

Fail fast: an expression the reader kept (LIGHTS*1.2) on a record of a mapped class raises, naming the object, its file and line and the slot (GLM-8). The walk raises on a coil that cannot sit on its island (a deck defect, listed in tests/decks/README.md).

S1 (approved 2026-11-09 with S1-2 and S1-3 amended; built 2026-11-09)

S1 maps the buses and the swing source. Two artifacts, written by importer/cimtbl/bus.py:

# artifact from shape
1 bus.cimtbl every root bus object: any node or triplex_node subclass (node, meter, substation, triplex_node, triplex_meter, and load, capacitor, triplex_load, ... when they are a root) ConnectivityNode + BaseVoltage
2 source.cimtbl every substation and every bus with bustype SWING source (EnergySource), BasePower

bus.cimtbl is not one native table: in GridLAB-D a load, a capacitor and a meter are each a node, and lines end on them, so every bus must exist before any equipment file (plan section 2, amended in S0). It is the topology walk's result, as DSS bus.cimtbl is.

Buses

# GridLAB-D buses -> ConnectivityNode, BaseVoltage from the topology walk (cimtopology.core); 21 buses.
# Mapping: cimhub_gridlabd/docs/CIMTBL_MAPPING.md#buses
Table ConnectivityNode: mRID, name, BaseVoltage, ConnectivityNodeContainer=fdr_IEEE13_cdpsm
    sourcebus, sourcebus, bv_115kv
    611,       611,       bv_4p16kv  # children: cap_cap2, ld_611
    ...
    634,       634,       bv_480v    # children: 634_pvmtr, 634_stmtr, ld_634c
    house,     house,     bv_240v    # children: house_pvmtr, house_stmtr, ld_house
  • Identity: mRID and name are the GLM name, in source case (D3), with no prefix: the cell every later node column writes. GLM names are unique across a model, and every equipment mRID has a prefix, so they cannot collide.
  • Root buses (GLM-4): a bus object whose parent is a bus is solved by GridLAB-D as its parent's bus. It gets no row; its equipment lands on the root of its parent chain, and its name is listed in the root row's comment (# children: ...). A parent that is not a bus object, a loop, or a child whose phase conductors are not a subset of its root's raises.
  • BaseVoltage (GLM-1, decided 2026-11-09): the walk's kV for the bus (source and transformer ratings). Rows are sorted highest voltage first, then by name. A bus the walk does not reach has no row; equipment on it raises in its own mapper.
  • nominal_voltage check: every bus object, root or child, is checked on the walk's system: line_voltage(nominal_voltage, system) against the walk's kV. A disagreement over 10 % is listed in the table comment, not raised: grouped by how it disagrees: # nominal_voltage disagrees with the walk (10%): 480.0 V (0.8314 kV 3-phase) on bv_480v (12): R1-12-47-4_load_1, .... The taxonomy feeders give every meter 480 V (plan section 3.5); the IEEE decks agree everywhere.
  • Untranscribed: the groups are object metadata, location (home: the location shape, mapped when a deck sets it), reliability, dynamics, solver state and outputs, metering and billing, and the bus's own loads (power_12, power_A, ...), which the load slice S4a maps. With 80 to 200 slots per class, the table comment lists the untranscribed slots this model sets, with counts (# untranscribed, set here: triplex_node power_12 7492), rather than every name: D5's purpose (nothing disappears silently) holds, and the full list is the field tables below. Until S4a the taxonomy triplex nodes' power_12 loads are listed there, not mapped.

Source

# GridLAB-D substation and SWING buses -> EnergySource; 1 source.
# Mapping: cimhub_gridlabd/docs/CIMTBL_MAPPING.md#source
Object BasePower: mRID=sbase_sourcebus, basePower (MVA)=12.0
Table EnergySource: mRID, name, node, phases, nominalVoltage (V), voltageMagnitude (V), voltageAngle (deg), BaseVoltage, EquipmentContainer=sub_IEEE13_cdpsm
    src_sourcebus, sourcebus, sourcebus, , 114999.99834276171, 114999.99834276171, 0.0, bv_115kv  # derived: line_voltage(nominal_voltage=66395.28), line_voltage(|positive_sequence_voltage|=66395.28)
  • Identity: mRID = src_ + name; node = the bus itself (a swing bus with a parent raises).
  • Which buses: every substation (GridLAB-D's substation is always the swing) and every bus with bustype SWING. SWING_PQ is ignored, a plain bus with a row comment saying so (S1-2, the user: revisit if something breaks): it becomes a swing only when its island separates (IEEE13_cdpsm bus 634, under the PV and storage meters).
  • Phases: the phase letters of phases, N dropped (a grounded wye source); ABC is a blank cell (phases_cell). One or three conductors; any other count raises (the walk already does).
  • Voltage (derived, topology.line_voltage): nominalVoltage = line_voltage(nominal_voltage) on the walk's system. voltageMagnitude = line_voltage(|V|) and voltageAngle = arg(V) in degrees, where V is the substation's positive_sequence_voltage, else the bus's voltage_A (voltage_1 on a triplex bus). Unset: V = nominal_voltage at 0 degrees, listed as # defaulted. Units are the written ones (V). |V| more than 10 % from nominal_voltage raises: the deck gives the wrong source voltage (or the wrong defines).
  • reference_phase: unset or PHASE_A; anything else raises (the angle would refer to another phase).
  • Impedance: a stiff default (S1-3, the user: so round trips work). GridLAB-D's swing bus has no source impedance, and the DSS exporter needs one. bus.default_source_impedance(kV) gives |Z| = kV² / 10,000 MVA with X/R 10, the same in zero sequence (12.47 kV: 0.0155 ohm; 115 kV: 1.32 ohm), listed on the row as # defaulted. The constants are DEFAULT_SHORT_CIRCUIT_MVA and DEFAULT_X_OVER_R.
  • base_power (substation): copied to a BasePower row in its written unit (12MVA gives basePower (MVA)=12.0). Two substations with different bases raise in cimtables.
  • Untranscribed: power_convergence_value (solver setting), the sequence voltages other than positive, the transmission interface slots, and every bus slot above.

Fail fast (S1)

condition message names
a parent that is not a bus object, or a parent loop the object and its chain
a link whose from or to names no bus object the link and the name
a link, load, capacitor or inverter on an island no swing bus reaches the equipment and its bus
a model name that is a part's name (bus, load, player, ...) the name, when the importer is made
a child bus whose phases are not a subset of its root's both objects and their phases
a swing bus with a parent the bus
a source on 2 conductors the bus and its phases
a source voltage more than 10 % from nominal_voltage the bus, both values
reference_phase other than PHASE_A the bus
a slot of a bus class no group classifies (schema regeneration) class and slot (bus.classify)

Decisions for S1

# question recommendation
S1-1 Files approved: bus.cimtbl for every root bus and source.cimtbl for the sources
S1-2 SWING_PQ approved, amended: ignored, a plain bus with a row comment; revisit if something breaks
S1-3 Source impedance amended by the user: a small default impedance so round trips work (stiff source, above)
S1-4 Source voltage approved: derived from positive_sequence_voltage / voltage_A; over 10 % from nominal raises. The tests pass each Java export its own VSOURCE (IEEE13: 66395.28, IEEE123: 2401.78 = 4.16 kV / sqrt 3)
S1-5 nominal_voltage disagreements approved: listed on bus.cimtbl's table comment, for roots and children alike
S1-6 Field tables approved: generated from bus.py FIELDS with fields_table (below)

Built (2026-11-09)

  • importer/cimtbl/bus.py (map_buses, map_source, default_source_impedance), wired into glm_to_cimtbl.py before MAPPING_ORDER. CLASSIFIED (every mapped class's FIELDS) drives the master's not-mapped list and the expression guard, which now raises only for a slot a mapper reads.
  • Atoms tests/atoms/bus/feeder (substation + base_power, child load and triplex node, a 480 V meter on a 480 V bus, SWING_PQ, center tap), tests/atoms/source/swing_node (taxonomy-style SWING node, polar voltage) and tests/atoms/source/one_phase (a one-phase SWING node: its nominalVoltage is the coil's, no sqrt 3); goldens tests/goldens/IEEE13_cdpsm/{bus,source}.cimtbl; tests/test_cimtbl_bus.py.
  • Every deck binds master + bus + source except the two listed deck defects (IEEE123_transactive's Object, IEEE13_houses' bus-634 center taps).

Explicit fields (every other slot is in an untranscribed group, bus.py _GROUPS)

class slot kind target
all bus classes name copied ConnectivityNode.mRID, name (root buses)
parent structural root merge (GLM-4)
phases structural child check; EnergySource.phases
nominal_voltage structural check against the walk; EnergySource.nominalVoltage (derived)
bustype structural SWING: an EnergySource
node, meter, substation voltage_A derived swing only: voltageMagnitude, voltageAngle
triplex_node, triplex_meter voltage_1 derived swing only: voltageMagnitude, voltageAngle
substation positive_sequence_voltage derived voltageMagnitude, voltageAngle
reference_phase structural unset or PHASE_A
base_power copied BasePower.basePower (written unit)

Field tables (generated: fields_table(cls, records, fields=FIELDS[cls]), samples from tests/decks)

node

Node field type samples kind target
name Union[str, NodeName] 1, 10, 100 copied ConnectivityNode.mRID, ConnectivityNode.name; root buses only; a child bus is its root's node (GLM-4)
parent Optional[str] 611, GC-12-47-1_meter_4, R1-12-47-3_meter_22 structural a bus whose parent is a bus is solved as the root of its parent chain: no node of its own; its name is listed on the root's row (GLM-4)
groupid Optional[str] untranscribed object metadata with no network-profile home
latitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
longitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
in_svc Optional[str] untranscribed object metadata with no network-profile home
out_svc Optional[str] untranscribed object metadata with no network-profile home
rank Optional[str] untranscribed object metadata with no network-profile home
flags Optional[str] untranscribed object metadata with no network-profile home
phases Optional[str] ABCN, AN, CN structural a child's phase conductors must be a subset of its root's; on a swing bus, EnergySource.phases (blank when ABC)
nominal_voltage Optional[float] 2401.78, 277.13, 2401.7771 structural checked against the walk's kV on the bus's system (line_voltage); a disagreement over 10 % is listed in bus.cimtbl, not written (GLM-1). On a swing bus: EnergySource.nominalVoltage, derived by line_voltage
inrush_integration_method Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
condition Optional[str] untranscribed object metadata with no network-profile home
solution Optional[str] untranscribed object metadata with no network-profile home
bustype Optional[str] SWING_PQ, SWING structural SWING: an EnergySource row (source.cimtbl). PQ, PV, SWING_PQ: a plain bus. SWING_PQ only turns into a swing when islanded
busflags Optional[str] untranscribed object metadata with no network-profile home
reference_bus Optional[str] untranscribed object metadata with no network-profile home
maximum_voltage_error Optional[float] untranscribed object metadata with no network-profile home
voltage_A Union[dict, Complex, NoneType] Complex({'real': 2401.7771, 'imag': 0..., Complex({'real': 480.0, 'imag': 0.0}), Complex({'real': 7200.0, 'imag': 0.0}) derived on a SWING bus only: EnergySource voltageMagnitude = line_voltage(
voltage_B Union[dict, Complex, NoneType] Complex({'real': -1200.8886, 'imag': ..., Complex({'real': -240.0, 'imag': -415..., Complex({'real': -3600.0, 'imag': -62... untranscribed the solver's initial guess
voltage_C Union[dict, Complex, NoneType] Complex({'real': -1200.8886, 'imag': ..., Complex({'real': -240.0, 'imag': 415...., Complex({'real': -3600.0, 'imag': 623... untranscribed the solver's initial guess
voltage_AB Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_BC Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_CA Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
current_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
prerotated_current_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
deltamode_generator_current_A Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_generator_current_B Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_generator_current_C Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_PGenTotal Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_all_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
NR_powerflow_parent Optional[str] untranscribed object metadata with no network-profile home
current_inj_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_inj_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_inj_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
residential_nominal_current_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_A_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_A_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
house_present Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
frequency_measure_type Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
sfm_Tf Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Kp Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Ki Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
measured_angle_A Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_A Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_B Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_B Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_C Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_C Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
service_status Optional[str] untranscribed object metadata with no network-profile home
service_status_double Optional[float] untranscribed object metadata with no network-profile home
previous_uptime Optional[float] untranscribed object metadata with no network-profile home
current_uptime Optional[float] untranscribed object metadata with no network-profile home
Norton_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
Norton_dynamic_child Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
generator_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
reset_disabled_island_state Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
GFA_enable Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_reconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_status Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_trip_method Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
topological_parent Optional[str] untranscribed object metadata with no network-profile home
behaving_as_swing Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home

meter

Meter field type samples kind target
name Union[str, MeterName] 634_pvmtr, 634_stmtr, GC-12-47-1_meter_1 copied ConnectivityNode.mRID, ConnectivityNode.name; root buses only; a child bus is its root's node (GLM-4)
parent Optional[str] 634 structural a bus whose parent is a bus is solved as the root of its parent chain: no node of its own; its name is listed on the root's row (GLM-4)
groupid Optional[str] untranscribed object metadata with no network-profile home
latitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
longitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
in_svc Optional[str] untranscribed object metadata with no network-profile home
out_svc Optional[str] untranscribed object metadata with no network-profile home
rank Optional[str] untranscribed object metadata with no network-profile home
flags Optional[str] untranscribed object metadata with no network-profile home
phases Optional[str] ABCN, CN, AN structural a child's phase conductors must be a subset of its root's; on a swing bus, EnergySource.phases (blank when ABC)
nominal_voltage Optional[float] 277.13, 480.0, 7200.0 structural checked against the walk's kV on the bus's system (line_voltage); a disagreement over 10 % is listed in bus.cimtbl, not written (GLM-1). On a swing bus: EnergySource.nominalVoltage, derived by line_voltage
inrush_integration_method Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
condition Optional[str] untranscribed object metadata with no network-profile home
solution Optional[str] untranscribed object metadata with no network-profile home
bustype Optional[str] structural SWING: an EnergySource row (source.cimtbl). PQ, PV, SWING_PQ: a plain bus. SWING_PQ only turns into a swing when islanded
busflags Optional[str] untranscribed object metadata with no network-profile home
reference_bus Optional[str] untranscribed object metadata with no network-profile home
maximum_voltage_error Optional[float] untranscribed object metadata with no network-profile home
voltage_A Union[dict, Complex, NoneType] Complex({'real': 7200.0, 'imag': 0.0}) derived on a SWING bus only: EnergySource voltageMagnitude = line_voltage(
voltage_B Union[dict, Complex, NoneType] Complex({'real': -3600.0, 'imag': -62... untranscribed the solver's initial guess
voltage_C Union[dict, Complex, NoneType] Complex({'real': -3600.0, 'imag': 623... untranscribed the solver's initial guess
voltage_AB Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_BC Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_CA Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
current_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
prerotated_current_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
deltamode_generator_current_A Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_generator_current_B Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_generator_current_C Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_PGenTotal Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_all_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
NR_powerflow_parent Optional[str] untranscribed object metadata with no network-profile home
current_inj_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_inj_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_inj_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
residential_nominal_current_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_A_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_A_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
house_present Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
frequency_measure_type Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
sfm_Tf Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Kp Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Ki Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
measured_angle_A Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_A Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_B Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_B Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_C Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_C Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
service_status Optional[str] untranscribed object metadata with no network-profile home
service_status_double Optional[float] untranscribed object metadata with no network-profile home
previous_uptime Optional[float] untranscribed object metadata with no network-profile home
current_uptime Optional[float] untranscribed object metadata with no network-profile home
Norton_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
Norton_dynamic_child Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
generator_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
reset_disabled_island_state Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
GFA_enable Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_reconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_status Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_trip_method Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
topological_parent Optional[str] untranscribed object metadata with no network-profile home
behaving_as_swing Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
measured_real_energy Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_energy_delta Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_energy Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_energy_delta Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_energy_delta_timestep Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_power Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_power_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_power_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_power_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_demand Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_power Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_power Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
meter_power_consumption Union[dict, Complex, NoneType] untranscribed metering and billing
measured_voltage_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_voltage_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_voltage_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_voltage_AB Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_voltage_BC Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_voltage_CA Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_voltage_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_voltage_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_voltage_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_AB_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_BC_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_CA_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_voltage_AB_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_voltage_BC_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_voltage_CA_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_voltage_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_voltage_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_voltage_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_AB_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_BC_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_CA_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_voltage_AB_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_voltage_BC_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_voltage_CA_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_A_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_B_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_C_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_AB_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_BC_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_CA_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_real_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_reactive_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_power_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_power_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_power_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_power_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_real_power_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_reactive_power_A_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_power_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_power_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_power_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_power_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_real_power_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_reactive_power_B_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_power_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_power_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_power_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_power_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_real_power_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_reactive_power_C_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_stats_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_current_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_current_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_current_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
customer_interrupted Union[bool, Bool, NoneType] untranscribed metering and billing
customer_interrupted_secondary Union[bool, Bool, NoneType] untranscribed metering and billing
sustained_count Optional[int] untranscribed metering and billing
momentary_count Optional[int] untranscribed metering and billing
total_count Optional[int] untranscribed metering and billing
s_flag Optional[int] untranscribed metering and billing
t_flag Optional[int] untranscribed metering and billing
pre_load Union[dict, Complex, NoneType] untranscribed metering and billing
monthly_bill Optional[float] untranscribed metering and billing
previous_monthly_bill Optional[float] untranscribed metering and billing
previous_monthly_energy Optional[float] untranscribed metering and billing
monthly_fee Optional[float] untranscribed metering and billing
monthly_energy Optional[float] untranscribed metering and billing
bill_mode Optional[str] untranscribed metering and billing
power_market Optional[str] untranscribed metering and billing
bill_day Optional[int] untranscribed metering and billing
price Optional[float] untranscribed metering and billing
price_base Optional[float] untranscribed metering and billing
first_tier_price Optional[float] untranscribed metering and billing
first_tier_energy Optional[float] untranscribed metering and billing
second_tier_price Optional[float] untranscribed metering and billing
second_tier_energy Optional[float] untranscribed metering and billing
third_tier_price Optional[float] untranscribed metering and billing
third_tier_energy Optional[float] untranscribed metering and billing

substation

Substation field type samples kind target
name Union[str, SubstationName] 150, sourcebus copied ConnectivityNode.mRID, ConnectivityNode.name; root buses only; a child bus is its root's node (GLM-4)
parent Optional[str] structural a bus whose parent is a bus is solved as the root of its parent chain: no node of its own; its name is listed on the root's row (GLM-4)
groupid Optional[str] untranscribed object metadata with no network-profile home
latitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
longitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
in_svc Optional[str] untranscribed object metadata with no network-profile home
out_svc Optional[str] untranscribed object metadata with no network-profile home
rank Optional[str] untranscribed object metadata with no network-profile home
flags Optional[str] untranscribed object metadata with no network-profile home
phases Optional[str] ABCN structural a child's phase conductors must be a subset of its root's; on a swing bus, EnergySource.phases (blank when ABC)
nominal_voltage Optional[float] 2401.78, 66395.28 structural checked against the walk's kV on the bus's system (line_voltage); a disagreement over 10 % is listed in bus.cimtbl, not written (GLM-1). On a swing bus: EnergySource.nominalVoltage, derived by line_voltage
inrush_integration_method Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
condition Optional[str] untranscribed object metadata with no network-profile home
solution Optional[str] untranscribed object metadata with no network-profile home
bustype Optional[str] SWING structural SWING: an EnergySource row (source.cimtbl). PQ, PV, SWING_PQ: a plain bus. SWING_PQ only turns into a swing when islanded
busflags Optional[str] untranscribed object metadata with no network-profile home
reference_bus Optional[str] untranscribed object metadata with no network-profile home
maximum_voltage_error Optional[float] untranscribed object metadata with no network-profile home
voltage_A Union[dict, Complex, NoneType] derived on a SWING bus only: EnergySource voltageMagnitude = line_voltage(
voltage_B Union[dict, Complex, NoneType] untranscribed the solver's initial guess
voltage_C Union[dict, Complex, NoneType] untranscribed the solver's initial guess
voltage_AB Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_BC Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_CA Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
current_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
prerotated_current_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
deltamode_generator_current_A Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_generator_current_B Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_generator_current_C Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_PGenTotal Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_all_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
NR_powerflow_parent Optional[str] untranscribed object metadata with no network-profile home
current_inj_A Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_inj_B Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_inj_C Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_AB Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_BC Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_CA Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_AN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_BN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_CN Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
residential_nominal_current_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_A_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_A_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_B_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_C_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
house_present Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
frequency_measure_type Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
sfm_Tf Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Kp Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Ki Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
measured_angle_A Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_A Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_B Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_B Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_C Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_C Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
service_status Optional[str] untranscribed object metadata with no network-profile home
service_status_double Optional[float] untranscribed object metadata with no network-profile home
previous_uptime Optional[float] untranscribed object metadata with no network-profile home
current_uptime Optional[float] untranscribed object metadata with no network-profile home
Norton_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
Norton_dynamic_child Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
generator_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
reset_disabled_island_state Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
GFA_enable Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_reconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_status Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_trip_method Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
topological_parent Optional[str] untranscribed object metadata with no network-profile home
behaving_as_swing Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
zero_sequence_voltage Union[dict, Complex, NoneType] untranscribed solver output
positive_sequence_voltage Union[dict, Complex, NoneType] Complex({'real': 2401.78, 'imag': 0.0}), Complex({'real': 66395.28, 'imag': 0.0}) derived EnergySource voltageMagnitude = line_voltage(
negative_sequence_voltage Union[dict, Complex, NoneType] untranscribed solver output
base_power Optional[float] 12.0 copied BasePower.basePower ({unit}); the system base (cimtables BasePower), in its written unit
power_convergence_value Optional[float] 100.0 untranscribed solver setting
reference_phase Optional[str] structural the phase the angle refers to: unset or PHASE_A, else raises
transmission_level_constant_power_load Union[dict, Complex, NoneType] untranscribed substation transmission interface (co-simulation with a transmission solver)
transmission_level_constant_current_load Union[dict, Complex, NoneType] untranscribed substation transmission interface (co-simulation with a transmission solver)
transmission_level_constant_impedance_load Union[dict, Complex, NoneType] untranscribed substation transmission interface (co-simulation with a transmission solver)
distribution_load Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_power_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_power_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_power_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_voltage_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_voltage_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_voltage_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_voltage_AB Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_voltage_BC Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_voltage_CA Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_current_A Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_current_B Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_current_C Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
distribution_real_energy Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network

triplex_node

TriplexNode field type samples kind target
name Union[str, TriplexNodeName] house, trip_node1, trip_node10 copied ConnectivityNode.mRID, ConnectivityNode.name; root buses only; a child bus is its root's node (GLM-4)
parent Optional[str] R1-12-47-3_tm_1 structural a bus whose parent is a bus is solved as the root of its parent chain: no node of its own; its name is listed on the root's row (GLM-4)
groupid Optional[str] untranscribed object metadata with no network-profile home
latitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
longitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
in_svc Optional[str] untranscribed object metadata with no network-profile home
out_svc Optional[str] untranscribed object metadata with no network-profile home
rank Optional[str] untranscribed object metadata with no network-profile home
flags Optional[str] untranscribed object metadata with no network-profile home
phases Optional[str] BS, CS, AS structural a child's phase conductors must be a subset of its root's; on a swing bus, EnergySource.phases (blank when ABC)
nominal_voltage Optional[float] 120.09, 120.0 structural checked against the walk's kV on the bus's system (line_voltage); a disagreement over 10 % is listed in bus.cimtbl, not written (GLM-1). On a swing bus: EnergySource.nominalVoltage, derived by line_voltage
inrush_integration_method Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
condition Optional[str] untranscribed object metadata with no network-profile home
solution Optional[str] untranscribed object metadata with no network-profile home
bustype Union[str, ForwardRef('Bustype'), NoneType] structural SWING: an EnergySource row (source.cimtbl). PQ, PV, SWING_PQ: a plain bus. SWING_PQ only turns into a swing when islanded
busflags Optional[str] untranscribed object metadata with no network-profile home
reference_bus Optional[str] untranscribed object metadata with no network-profile home
maximum_voltage_error Optional[float] untranscribed object metadata with no network-profile home
voltage_1 Union[dict, Complex, NoneType] Complex({'real': -60.0, 'imag': -103.... derived on a SWING bus only: EnergySource voltageMagnitude = line_voltage(
voltage_2 Union[dict, Complex, NoneType] Complex({'real': -60.0, 'imag': -103.... untranscribed the solver's initial guess
voltage_N Union[dict, Complex, NoneType] Complex({'real': 0.0, 'imag': 0.0}) untranscribed the solver's initial guess
voltage_12 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_1N Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_2N Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_1 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_2 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_12 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
deltamode_generator_current_12 Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_PGenTotal Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_all_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
NR_powerflow_parent Optional[str] untranscribed object metadata with no network-profile home
residential_nominal_current_1 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_2 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_12 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_1_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_1_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_2_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_2_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_12_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_12_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
current_1 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_2 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_N Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_12 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_1 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_2 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_12 Union[dict, Complex, NoneType] Complex({'real': 175181.0364, 'imag':... untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_1 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_2 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_12 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
house_present Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
Norton_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
Norton_dynamic_child Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
generator_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
reset_disabled_island_state Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
GFA_enable Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_reconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_status Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_trip_method Union[str, ForwardRef('GfaTripMethod'), NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
service_status Union[str, ForwardRef('ServiceStatus'), NoneType] untranscribed object metadata with no network-profile home
service_status_double Optional[float] untranscribed object metadata with no network-profile home
previous_uptime Optional[float] untranscribed object metadata with no network-profile home
current_uptime Optional[float] untranscribed object metadata with no network-profile home
topological_parent Optional[str] untranscribed object metadata with no network-profile home
behaving_as_swing Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
frequency_measure_type Union[str, ForwardRef('FrequencyMeasureType'), NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
sfm_Tf Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Kp Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Ki Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
measured_angle_1 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_1 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_2 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_2 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_12 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_12 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network

triplex_meter

TriplexMeter field type samples kind target
name Union[str, TriplexMeterName] house_pvmtr, house_stmtr, trip_meter1 copied ConnectivityNode.mRID, ConnectivityNode.name; root buses only; a child bus is its root's node (GLM-4)
parent Optional[str] house structural a bus whose parent is a bus is solved as the root of its parent chain: no node of its own; its name is listed on the root's row (GLM-4)
groupid Optional[str] untranscribed object metadata with no network-profile home
latitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
longitude Optional[str] untranscribed home: the location shape (EquipmentLocation); mapped when a deck sets it
in_svc Optional[str] untranscribed object metadata with no network-profile home
out_svc Optional[str] untranscribed object metadata with no network-profile home
rank Optional[str] untranscribed object metadata with no network-profile home
flags Optional[str] untranscribed object metadata with no network-profile home
phases Optional[str] BS, CS, AS structural a child's phase conductors must be a subset of its root's; on a swing bus, EnergySource.phases (blank when ABC)
nominal_voltage Optional[float] 120.09, 120.0 structural checked against the walk's kV on the bus's system (line_voltage); a disagreement over 10 % is listed in bus.cimtbl, not written (GLM-1). On a swing bus: EnergySource.nominalVoltage, derived by line_voltage
inrush_integration_method Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
condition Optional[str] untranscribed object metadata with no network-profile home
solution Optional[str] untranscribed object metadata with no network-profile home
bustype Union[str, ForwardRef('Bustype'), NoneType] structural SWING: an EnergySource row (source.cimtbl). PQ, PV, SWING_PQ: a plain bus. SWING_PQ only turns into a swing when islanded
busflags Optional[str] untranscribed object metadata with no network-profile home
reference_bus Optional[str] untranscribed object metadata with no network-profile home
maximum_voltage_error Optional[float] untranscribed object metadata with no network-profile home
voltage_1 Union[dict, Complex, NoneType] Complex({'real': -60.0, 'imag': -103.... derived on a SWING bus only: EnergySource voltageMagnitude = line_voltage(
voltage_2 Union[dict, Complex, NoneType] Complex({'real': -60.0, 'imag': -103.... untranscribed the solver's initial guess
voltage_N Union[dict, Complex, NoneType] Complex({'real': 0.0, 'imag': 0.0}) untranscribed the solver's initial guess
voltage_12 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_1N Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
voltage_2N Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_1 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_2 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
prerotated_current_12 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
deltamode_generator_current_12 Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_PGenTotal Union[dict, Complex, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
deltamode_full_Y_all_matrix Optional[str] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
NR_powerflow_parent Optional[str] untranscribed object metadata with no network-profile home
residential_nominal_current_1 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_2 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_12 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_1_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_1_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_2_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_2_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_12_real Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
residential_nominal_current_12_imag Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
current_1 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_2 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_N Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
current_12 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_1 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_2 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
power_12 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_1 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_2 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
shunt_12 Union[dict, Complex, NoneType] untranscribed a load on the bus (constant power, current or impedance): load slice S4a; until then listed, never set silently
house_present Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
Norton_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
Norton_dynamic_child Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
generator_dynamic Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
reset_disabled_island_state Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
GFA_enable Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_low_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_high_trip Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_reconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_freq_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_volt_disconnect_time Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_status Union[bool, Bool, NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
GFA_trip_method Union[str, ForwardRef('GfaTripMethod'), NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
service_status Union[str, ForwardRef('ServiceStatus'), NoneType] untranscribed object metadata with no network-profile home
service_status_double Optional[float] untranscribed object metadata with no network-profile home
previous_uptime Optional[float] untranscribed object metadata with no network-profile home
current_uptime Optional[float] untranscribed object metadata with no network-profile home
topological_parent Optional[str] untranscribed object metadata with no network-profile home
behaving_as_swing Union[bool, Bool, NoneType] untranscribed object metadata with no network-profile home
frequency_measure_type Union[str, ForwardRef('FrequencyMeasureType'), NoneType] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
sfm_Tf Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Kp Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
pll_Ki Optional[float] untranscribed dynamics (deltamode, PLL, frequency measurement, grid-friendly appliance trips)
measured_angle_1 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_1 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_2 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_2 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_angle_12 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency_12 Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_frequency Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_energy Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_energy_delta Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_energy Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_energy_delta Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_energy_delta_timestep Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_power Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
indiv_measured_power_1 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
indiv_measured_power_2 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
indiv_measured_power_N Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_demand Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_power Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_power Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
meter_power_consumption Union[dict, Complex, NoneType] untranscribed metering and billing
measured_voltage_1 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_voltage_2 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_voltage_N Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_1_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_2_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_voltage_12_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_imag_max_voltage_1_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_imag_max_voltage_2_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_imag_max_voltage_12_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_1_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_2_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_voltage_12_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_imag_min_voltage_1_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_imag_min_voltage_2_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_imag_min_voltage_12_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_1_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_2_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_voltage_12_mag_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_max_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_max_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_real_min_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_reactive_min_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_real_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_avg_reactive_power_in_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_stats_interval Optional[float] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_current_1 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_current_2 Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
measured_current_N Union[dict, Complex, NoneType] untranscribed solver state and outputs: the initial guess and the solution, not the network
customer_interrupted Union[bool, Bool, NoneType] untranscribed metering and billing
customer_interrupted_secondary Union[bool, Bool, NoneType] untranscribed metering and billing
sustained_count Optional[int] untranscribed metering and billing
momentary_count Optional[int] untranscribed metering and billing
total_count Optional[int] untranscribed metering and billing
s_flag Optional[int] untranscribed metering and billing
t_flag Optional[int] untranscribed metering and billing
pre_load Union[dict, Complex, NoneType] untranscribed metering and billing
monthly_bill Optional[float] untranscribed metering and billing
previous_monthly_bill Optional[float] untranscribed metering and billing
previous_monthly_energy Optional[float] untranscribed metering and billing
monthly_fee Optional[float] untranscribed metering and billing
monthly_energy Optional[float] untranscribed metering and billing
bill_mode Union[str, ForwardRef('BillMode'), NoneType] untranscribed metering and billing
power_market Optional[str] untranscribed metering and billing
bill_day Optional[int] untranscribed metering and billing
price Optional[float] untranscribed metering and billing
price_base Optional[float] untranscribed metering and billing
first_tier_price Optional[float] untranscribed metering and billing
first_tier_energy Optional[float] untranscribed metering and billing
second_tier_price Optional[float] untranscribed metering and billing
second_tier_energy Optional[float] untranscribed metering and billing
third_tier_price Optional[float] untranscribed metering and billing
third_tier_energy Optional[float] untranscribed metering and billing

S2: catalogs (approved 2026-11-09 with S2-3 amended)

S2 maps the conductor, spacing and line configuration catalogs: six artifacts, one per native table (D4), in the plan's section 2 order. Samples and counts come from the census of all 29 decks (28 read; IEEE123_transactive stops at read). GridLAB-D citations are to the C++ source (powerflow/, the checkout the schema was scraped from).

# artifact native class (records in the decks) CIM mRID
2 overhead_line_conductor.cimtbl overhead_line_conductor (163) OverheadWireInfo ohc_<name>
2 underground_line_conductor.cimtbl underground_line_conductor (91) ConcentricNeutralCableInfo (84), TapeShieldCableInfo (6), OverheadWireInfo (1, a bare wire; S2-5) ugc_<name>
2 triplex_line_conductor.cimtbl triplex_line_conductor (25) OverheadWireInfo tpc_<name>
3 line_spacing.cimtbl line_spacing (238) ConductorDistanceSpacing + ConductorDistance (S2-2) spc_<name>
4 line_configuration.cimtbl line_configuration: 722 by spacing + conductors, 20 by z-matrix WireConfiguration + WireSequenceConfiguration, or PerLengthPhaseImpedance + PhaseImpedanceData wc_<name>, lc_<name>
4 triplex_line_configuration.cimtbl triplex_line_configuration (25, all by conductors) WireConfiguration + a derived ConductorDistanceSpacing (S2-8); a matrix: PerLengthPhaseImpedance + PhaseImpedanceData wc_<name>, wc_<name>_spc; lc_<name>, lc_<name>_wc

Identity (all six): prefix + the GLM name in source case (D3, GLM names are case-sensitive), never sanitized (tpc_triplex_4/0 AA is a quoted cell, I8). An unnamed object is <class>:<id> (S0), so ohc_overhead_line_conductor:3. One prefix per native class: GLM names are unique across a model, so they cannot collide. Child rows: <parent mRID>_<letter> (spc_602_ABCN_AB, wc_lcon_601_2_A, lc_lcon_mtx601_ABC_21).

Untranscribed on every catalog class: the object header (parent, groupid, latitude, longitude, in_svc, out_svc, rank, flags): a catalog object has no place or service state. Listed per row (# untranscribed: ...) when set, as the DSS catalogs do.

Conductors

# GridLAB-D overhead_line_conductor -> OverheadWireInfo (catalog).
Table OperationalLimitSet: mRID
    ohc_wire_acsr_556_5_limits
Table CurrentLimit: mRID, normalValue (A), OperationalLimitType, OperationalLimitSet
    ohc_wire_acsr_556_5_norm,  730.0, olt_normal,    ohc_wire_acsr_556_5_limits
    ohc_wire_acsr_556_5_emerg, 730.0, olt_emergency, ohc_wire_acsr_556_5_limits
Table OverheadWireInfo: mRID, name, gmr (ft), rAC50 (ohm/mi), radius (in), ratedCurrent (A), OperationalLimitSet
    ohc_wire_acsr_556_5, wire_acsr_556_5, 0.0311, 0.18972, 0.4635, 730.0, ohc_wire_acsr_556_5_limits  # derived: radius = diameter / 2
GLM slot kind target
name copied name; mRID = prefix + name
geometric_mean_radius (overhead, triplex), conductor_gmr (underground) copied gmr (ft)
resistance (overhead, triplex), conductor_resistance (underground) copied rAC50 (ohm/mi) (S2-6)
diameter (overhead), conductor_diameter (underground) derived radius = diameter / 2 (in)
outer_diameter copied CN, TS: diameterOverJacket (in); on a bare wire untranscribed (no jacket; the Java exporter writes 1.2 x diameter there, canBury)
neutral_strands copied CN neutralStrandCount; also selects the class (S2-5)
neutral_gmr copied CN neutralStrandGmr (ft)
neutral_diameter derived CN neutralStrandRadius = neutral_diameter / 2 (in)
neutral_resistance copied CN neutralStrandRDC20 (ohm/mi) (the strand's DC value, as the Java exporter reads it)
shield_thickness copied TS tapeThickness (in); also selects the class (S2-5)
shield_diameter copied TS diameterOverScreen (in) (the Java exporter writes it from there)
shield_gmr, shield_resistance untranscribed no CIM home; Kersting derives both from the screen diameter and tape thickness (eq. 4.89), and the Java exporter does. The taxonomy CN cables write 0.00
insulation_relative_permitivitty untranscribed no CableInfo home (as DSS EpsR); GridLAB-D default 1.0, the Java exports write 2.3
rating.summer.continuous copied ratedCurrent (A), and the normal CurrentLimit of the wire's AssetInfo OperationalLimitSet (D9, as DSS normamps)
rating.summer.emergency structural the emergency CurrentLimit of that set
rating.winter.continuous, rating.winter.emergency untranscribed equal to summer in every deck that sets them; a different value raises (S2-7)

Line spacings (S2-2, S2-3, S2-4)

# GridLAB-D line_spacing -> ConductorDistanceSpacing + ConductorDistance (catalog). The distances are copied as
# written; GLM gives no coordinates. Positions 1..n over the phases the distances name (fromPhase/toPhase);
# a height is a distance to earth.
Object ConductorDistanceSpacing: mRID=spc_spc_604_ACN, name=spc_604_ACN, isTemplate=true
Table ConductorDistance: mRID, ConductorDistanceSpacing=spc_spc_604_ACN, sequenceNumber1, conductorKind1, fromPhase, sequenceNumber2, conductorKind2, toPhase, distance (ft)
    spc_spc_604_ACN_AC, 1, phase,   A, 2, phase,   C, 7.0
    spc_spc_604_ACN_AN, 1, phase,   A, 3, neutral, N, 5.6569
    spc_spc_604_ACN_CN, 2, phase,   C, 3, neutral, N, 5.0
    spc_spc_604_ACN_AE, 1, phase,   A,  , earth,    , 28.0
    spc_spc_604_ACN_CE, 2, phase,   C,  , earth,    , 28.0
    spc_spc_604_ACN_NE, 3, neutral, N,  , earth,    , 24.0
GLM slot kind target
name copied ConductorDistanceSpacing.name; isTemplate = true
distance_AB, _AC, _BC, _AN, _BN, _CN structural one ConductorDistance each: distance in the written unit (in on 224 spacings, ft on 14; one table per unit), ends numbered and phased by S2-3, kind phase or neutral. Unset or 0: no row (S2-4)
distance_AE, _BE, _CE, _NE structural the conductor's height: a ConductorDistance to a position of kind earth, no second sequence number (the G5 getter convention). Only IEEE13_assets sets them

Line configurations (S2-9)

# geometry: spacing + conductors
Object WireConfiguration: mRID=wc_lcon_604_1, name=lcon_604_1, numberOfPhases=2, WireSpacing=spc_spc_604_ACN
Table WireSequenceConfiguration: mRID, WireConfiguration=wc_lcon_604_1, sequenceNumber, WireInfo
    wc_lcon_604_1_A, 1, ohc_wire_acsr_1/0
    wc_lcon_604_1_C, 2, ohc_wire_acsr_1/0
    wc_lcon_604_1_N, 3, ohc_wire_acsr_1/0

# matrix: z11..z33
Object PerLengthPhaseImpedance: mRID=lc_lcon_mtx604_AC, name=lcon_mtx604_AC, conductorCount=2, calculatedFrequency (Hz)=60.0
Table PhaseImpedanceData: identifier, PhaseImpedance=lc_lcon_mtx604_AC, row, column, r (ohm/mi), x (ohm/mi), b (nS/mi)
    lc_lcon_mtx604_AC_11, 1, 1, 1.3238, 1.3569, 0.0  # A
    lc_lcon_mtx604_AC_21, 2, 1, 0.2066, 0.4591, 0.0  # C-A (z31)
    lc_lcon_mtx604_AC_22, 2, 2, 1.3294, 1.3471, 0.0  # C (z33)
GLM slot kind target
name copied WireConfiguration.name or PerLengthPhaseImpedance.name
spacing structural WireConfiguration.WireSpacing = spc_<spacing>
conductor_A, _B, _C, _N structural one WireSequenceConfiguration each, sequenceNumber 1..n in ABCN order (S2-3), equal to its spacing's position for the same phase, WireInfo = the conductor's mRID (its class gives the prefix); numberOfPhases = the phase conductors set
z11 .. z33 structural form selection; one PhaseImpedanceData per lower-triangle element: r, x = the real and imaginary parts (ohm/mi). Rows and columns are compacted in letter order (CIM: 1 to conductorCount), so z31 of an AC code is row 2, column 1
c11 .. c33 derived b = 2 pi f c (cimhub_core.derived.capacitance.b_from_c): nF/mi gives nS/mi, f the base frequency (powerflow::nominal_frequency, which GridLAB-D uses); calculatedFrequency = f. CIM's PhaseImpedanceData has no capacitance, so GLM-11's "c verbatim" is amended. Unset with its z set: GridLAB-D's 0 (create()), # defaulted
rating.* structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet (1 triplex configuration sets it)

Triplex line configurations (S2-8)

# derived: D12 = diameter + 2 insulation_thickness, D1N = D2N = diameter + insulation_thickness (triplex_line.cpp:386)
Object ConductorDistanceSpacing: mRID=wc_triplex_line_configuration:1_spc, name=triplex_line_configuration:1, isTemplate=true
Table ConductorDistance: mRID, ConductorDistanceSpacing=wc_triplex_line_configuration:1_spc, sequenceNumber1, conductorKind1, sequenceNumber2, conductorKind2, distance (in)
    wc_triplex_line_configuration:1_spc_12, 1, phase, 2, phase,   0.682
    wc_triplex_line_configuration:1_spc_1N, 1, phase, 3, neutral, 0.602
    wc_triplex_line_configuration:1_spc_2N, 2, phase, 3, neutral, 0.602
Object WireConfiguration: mRID=wc_triplex_line_configuration:1, name=triplex_line_configuration:1, numberOfPhases=2, WireSpacing=wc_triplex_line_configuration:1_spc
Table WireSequenceConfiguration: ...  sequenceNumber 1 (conductor_1), 2 (conductor_2), 3 (conductor_N); the spacing's phases s1, s2, N
GLM slot kind target
conductor_1, conductor_2, conductor_N structural WireSequenceConfiguration 1, 2, 3 (GridLAB-D keeps N in its phase C slot, triplex_line_configuration.cpp:35); all three required (triplex_line.cpp throws)
diameter, insulation_thickness derived the spacing's three distances, in their written unit (in); triplex_spacing, cited formula. The exporter inverts it: t = D12 - D1N, d = 2 D1N - D12
spacing, conductor_A .. _C, z13, z23, z31 .. z33, c11 .. c33 structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
z11, z12, z21, z22 structural the matrix form, which GridLAB-D uses as given on legs 1 and 2 (triplex_line.cpp:315): a template PerLengthPhaseImpedance lc_<name> (conductorCount=2, isTemplate=true) with PhaseImpedanceData rows 1 (s1) and 2 (s2), r and x the real and imaginary parts, b 0 (the triplex line has no shunt admittance), held by WireConfiguration lc_<name>_wc as a line_configuration matrix is (S2-9). z11 and z22 are required, z12 must equal z21, and matrix with geometry raises (GridLAB-D would use the matrix). Its lines are s1s2 (no N, as a matrix line). This is what the exporter writes for a CIM triplex matrix (X27)

Fail fast (S2)

condition why
a conductor without its GMR or resistance GridLAB-D takes 0, and ln(1/GMR) fails
an underground conductor with both neutral_strands and shield_thickness two cable kinds
a winter rating that differs from summer no season home is mapped (S2-7)
a configuration with neither form, or with both z and conductors GridLAB-D uses the matrix when any diagonal is set (underground_line.cpp:162); GLM-11 amended (S2-9)
spacing without conductors, or conductors without spacing overhead_line.cpp:120 throws
a configuration whose phases differ from the phases its spacing's distances name S2-3
a conductor or spacing reference to no object, or to the wrong class (a triplex conductor on a line_configuration)
an off-diagonal z without both diagonals, or z_ij != z_ji none in the decks
a triplex configuration whose D12 or D1N is not positive triplex_line.cpp:390 throws

Decisions for S2

# question recommendation
S2-1 Files and identity approved: The six artifacts above, prefixes ohc_, ugc_, tpc_, spc_, wc_, lc_, source case
S2-2 Spacing form approved: ConductorDistanceSpacing, not XYSpacing (amends plan section 2 and the conductor-geometry skill's GLM row). GLM gives distances and heights, not coordinates: 224 of 238 spacings have no heights, and the taxonomy's are not planar (57.6 in between phases, 84 in from each phase to the neutral). Copied verbatim, it stays geometry and needs no derivation. The core G5 getters already read it
S2-3 Position numbers Amended by the user: the phasing goes on the GridAPPS-D extensions ConductorDistance.fromPhase/toPhase (A, B, C, N; triplex s1, s2, N; blank for earth), and the sequence numbers are compact, 1..n in ABCN order over the phases the spacing's written distances name, as OpenDSS numbers a LineSpacing (a line attaches position k to its k-th bus node, so DSS needs no C 3, N 4). A configuration numbers its conductors the same way over its own phases, and the two must agree: in all 28 readable decks every configuration's phases equal its spacing's (663) or the spacing has no distances (59 configurations on the 4 all-zero spacings). A disagreement raises. Matrices compact the same way (S2-9)
S2-4 Zero distances approved: GridLAB-D reads 0 as no mutual term (DIST in overhead_line.cpp, Z_DIST in underground_line.cpp), the same as unset; in CIM a 0 distance would be two coincident conductors. Not written; listed on the row (# 0 (GridLAB-D: no coupling): AB, AC). 30 spacings, 4 of them all zero (taxonomy underground spacings), which become spacings with no distances
S2-5 Underground conductor kinds approved: neutral_strands > 0: ConcentricNeutralCableInfo; shield_thickness > 0: TapeShieldCableInfo; neither: OverheadWireInfo (IEEE13_assets ugwire_cu_1/0, the bare 607 neutral the Java exporter re-emitted as an underground conductor; it matches the DSS import's WireData). One table per class in the one file
S2-6 Resistance approved: resistance / conductor_resistance to rAC50: Kersting's 50 C AC tables, and the Java exporter writes GLM resistance from rAC50. The DSS importer writes Rac to rAC25, so the IEEE13_assets comparison (GLM-16) lists that difference
S2-7 Conductor ratings approved: Summer continuous and emergency as written (D9). Unset ratings are not filled (an exception to GLM-3): GridLAB-D's create() constants (1000/2000 A overhead and underground, 202/212.1 A triplex) aren't the conductor's rating, and 156 taxonomy conductors set only summer.continuous, so a defaulted 2000 A emergency limit would sit on a 120 A conductor. The row lists the unset ones. Winter: untranscribed while it equals summer, raises otherwise
S2-8 Triplex geometry (GLM-12, amended) approved: A derived ConductorDistanceSpacing per triplex configuration (GridLAB-D's formula, which is Kersting's), not an XYSpacing. The triplex conductors become OverheadWireInfo (CIM has no triplex class; the insulation is on the configuration, and all 25 use one conductor for 1, 2 and N). GLM-12's z-matrix cross-check is dropped: the only triplex z-matrix is in IEEE123_transactive, which stops at read; the atom pins the formula
S2-9 Matrix configurations (GLM-11, amended) approved: As GLM-11, with b derived from c (above), rows compacted, and both forms on one record raising (none in the decks), since GridLAB-D would use the matrix. Amended 2026-11-21 (the user's rule, skill wire-configuration): the matrix is a template, isTemplate=true, held by a WireConfiguration lc_<name>_wc with no WireSpacing, which its lines reference
S2-10 Field tables approved: Generated from the mappers' FIELDS with fields_table once built, as S1-6

Expected differences from the DSS import of the same models (GLM-16): the IEEE13_cdpsm matrices match the DSS linecode.cimtbl r and x, but its five overhead configurations carry c = 0 (the Java exporter wrote no overhead capacitance), and their names are per phasing (lcon_mtx604_AC, lcon_mtx603_CB). IEEE13_assets: rAC50 vs rAC25; the spacings are distances, not XY (the same distances); the CN cable has no insulation diameters.

Done in core (exporter wave): 224 GLM spacings and every triplex spacing have no heights. The exporter reads them with getters.spacing.get_stored_distances, which does not need heights; only get_spacing_xy requires them. Plan section 7.

Built (2026-11-09)

  • importer/cimtbl/catalog.py (object header, ratings, references, the master's OperationalLimitType table), conductor.py (map_conductors, info_class), spacing.py (map_line_spacing, spacing_statements), configuration.py (map_line_configuration, map_triplex_line_configuration, triplex_spacing), wired into MAPPING_ORDER and CLASSIFIED. glm_schema.registry_unit spells GridLAB-D's Ohm units for the CIM unit registry (Ohm/mile is ohm/mile); the number stays as written.
  • The master now declares olt_normal and olt_emergency (as the DSS master), which the conductor limits name.
  • PhaseImpedanceData is keyed by identifier (it is not an IdentifiedObject in CIM 18), as in the shape.
  • Atom tests/atoms/catalog/catalog.glm (every form: rated and taxonomy overhead conductors, CN, TS and bare underground, spacings with heights, with an inch unit and a zero, geometry by alias, a mixed cable assembly, a 2-phase matrix, triplex) with one golden per part; golden tests/goldens/IEEE13_cdpsm/line_configuration.cimtbl; tests/test_cimtbl_catalog.py (classification, the formula and its inverse, the atom bound and read back through the core spacing getters, 11 fail-fast cases, and a sweep that counts every catalog object on every deck).
  • Every deck that binds S1 binds S2: 27 of 29, the same two deck defects.

Field tables (generated: fields_table(cls, records, fields=...), samples from tests/decks)

overhead_line_conductor

OverheadLineConductor field type samples kind target
name Union[str, OverheadLineConductorName] wire_acsr_1/0, wire_acsr_4/0, wire_acsr_556_5 copied OverheadWireInfo.name; mRID = ohc_ + name
parent Optional[str] untranscribed object header: a catalog object has no place or service state
groupid Optional[str] untranscribed object header: a catalog object has no place or service state
latitude Optional[str] untranscribed object header: a catalog object has no place or service state
longitude Optional[str] untranscribed object header: a catalog object has no place or service state
in_svc Optional[str] untranscribed object header: a catalog object has no place or service state
out_svc Optional[str] untranscribed object header: a catalog object has no place or service state
rank Optional[str] untranscribed object header: a catalog object has no place or service state
flags Optional[str] untranscribed object header: a catalog object has no place or service state
geometric_mean_radius Optional[float] 0.00446, 0.00814, 0.0311 copied OverheadWireInfo.gmr ({unit}); unset raises
resistance Optional[float] 1.1424, 0.60384, 0.18972 copied OverheadWireInfo.rAC50 ({unit}); Kersting's 50 C AC value, which the Java exporter writes from rAC50 (S2-6); unset raises
diameter Optional[float] 0.398, 0.563, 0.927 derived OverheadWireInfo.radius ({unit}); radius = diameter / 2 (radius_from_diameter), in the diameter's unit
rating_summer_continuous Optional[float] 230.0, 340.0, 730.0 copied OverheadWireInfo.ratedCurrent (A); also the normal CurrentLimit of the wire's AssetInfo OperationalLimitSet _limits. Unset: GridLAB-D's create() constant is not filled (S2-7)
rating_summer_emergency Optional[float] 230.0, 340.0, 730.0 structural the emergency CurrentLimit of that set; unset: not filled (S2-7)
rating_winter_continuous Optional[float] 230.0, 340.0, 730.0 untranscribed equal to summer in every deck that sets it; a different value raises (no season is mapped, S2-7)
rating_winter_emergency Optional[float] 230.0, 340.0, 730.0 untranscribed equal to summer in every deck that sets it; a different value raises (no season is mapped, S2-7)

underground_line_conductor

UndergroundLineConductor field type samples kind target
name Union[str, UndergroundLineConductorName] cncab_cn_250, tscab_ts_1/0, ugwire_cu_1/0 copied OverheadWireInfo.name, ConcentricNeutralCableInfo.name, TapeShieldCableInfo.name; mRID = ugc_ + name
parent Optional[str] untranscribed object header: a catalog object has no place or service state
groupid Optional[str] untranscribed object header: a catalog object has no place or service state
latitude Optional[str] untranscribed object header: a catalog object has no place or service state
longitude Optional[str] untranscribed object header: a catalog object has no place or service state
in_svc Optional[str] untranscribed object header: a catalog object has no place or service state
out_svc Optional[str] untranscribed object header: a catalog object has no place or service state
rank Optional[str] untranscribed object header: a catalog object has no place or service state
flags Optional[str] untranscribed object header: a catalog object has no place or service state
outer_diameter Optional[float] 1.29, 1.06, 0.4416 copied ConcentricNeutralCableInfo.diameterOverJacket ({unit}), TapeShieldCableInfo.diameterOverJacket ({unit}); on a bare wire untranscribed (no jacket; the Java exporter writes 1.2 x diameter, canBury)
conductor_gmr Optional[float] 0.0171, 0.0111, 0.01113 copied OverheadWireInfo.gmr ({unit}), ConcentricNeutralCableInfo.gmr ({unit}), TapeShieldCableInfo.gmr ({unit}); unset raises
conductor_diameter Optional[float] 0.567, 0.368, 1.152 derived OverheadWireInfo.radius ({unit}), ConcentricNeutralCableInfo.radius ({unit}), TapeShieldCableInfo.radius ({unit}); radius = diameter / 2 (radius_from_diameter), in the diameter's unit
conductor_resistance Optional[float] 0.41, 0.97, 0.607 copied OverheadWireInfo.rAC50 ({unit}), ConcentricNeutralCableInfo.rAC50 ({unit}), TapeShieldCableInfo.rAC50 ({unit}); Kersting's 50 C AC value, which the Java exporter writes from rAC50 (S2-6); unset raises
neutral_gmr Optional[float] 0.00208, 0.0111, 0.0842565914341201 copied ConcentricNeutralCableInfo.neutralStrandGmr ({unit})
neutral_diameter Optional[float] 0.0641, 0.0640837, 0.1019 derived ConcentricNeutralCableInfo.neutralStrandRadius ({unit}); neutralStrandRadius = neutral_diameter / 2 (radius_from_diameter)
neutral_resistance Optional[float] 14.8722, 14.872, 0.97 copied ConcentricNeutralCableInfo.neutralStrandRDC20 ({unit}); the strand's DC value, as the Java exporter reads it
neutral_strands Optional[int] 13, 6, 20 copied ConcentricNeutralCableInfo.neutralStrandCount; > 0 selects the CN class (S2-5)
shield_thickness Optional[float] 0.005 copied TapeShieldCableInfo.tapeThickness ({unit}); > 0 selects the TS class (S2-5)
shield_diameter Optional[float] 0.87 copied TapeShieldCableInfo.diameterOverScreen ({unit}); the Java exporter writes it from diameterOverScreen
insulation_relative_permitivitty Optional[float] 2.3 untranscribed no CableInfo home (as DSS EpsR); GridLAB-D default 1.0, the Java exports write 2.3
shield_gmr Optional[float] 0.03625, 0.0 untranscribed no CIM home; Kersting derives it from the screen diameter and tape thickness (eq. 4.89), as the Java exporter does. The taxonomy CN cables write 0.00
shield_resistance Optional[float] 4.327833, 0.0 untranscribed no CIM home; Kersting derives it from the screen diameter and tape thickness (eq. 4.89), as the Java exporter does. The taxonomy CN cables write 0.00
rating_summer_continuous Optional[float] 260.0, 165.0, 100.0 copied OverheadWireInfo.ratedCurrent (A), ConcentricNeutralCableInfo.ratedCurrent (A), TapeShieldCableInfo.ratedCurrent (A); also the normal CurrentLimit of the wire's AssetInfo OperationalLimitSet _limits. Unset: GridLAB-D's create() constant is not filled (S2-7)
rating_summer_emergency Optional[float] 260.0, 165.0, 100.0 structural the emergency CurrentLimit of that set; unset: not filled (S2-7)
rating_winter_continuous Optional[float] 260.0, 165.0, 100.0 untranscribed equal to summer in every deck that sets it; a different value raises (no season is mapped, S2-7)
rating_winter_emergency Optional[float] 260.0, 165.0, 100.0 untranscribed equal to summer in every deck that sets it; a different value raises (no season is mapped, S2-7)

triplex_line_conductor

TriplexLineConductor field type samples kind target
name Union[str, TriplexLineConductorName] tp_line_conductor, triplex_4/0 AA copied OverheadWireInfo.name; mRID = tpc_ + name
parent Optional[str] untranscribed object header: a catalog object has no place or service state
groupid Optional[str] untranscribed object header: a catalog object has no place or service state
latitude Optional[str] untranscribed object header: a catalog object has no place or service state
longitude Optional[str] untranscribed object header: a catalog object has no place or service state
in_svc Optional[str] untranscribed object header: a catalog object has no place or service state
out_svc Optional[str] untranscribed object header: a catalog object has no place or service state
rank Optional[str] untranscribed object header: a catalog object has no place or service state
flags Optional[str] untranscribed object header: a catalog object has no place or service state
resistance Optional[float] 0.97, 0.48 copied OverheadWireInfo.rAC50 ({unit}); Kersting's 50 C AC value, which the Java exporter writes from rAC50 (S2-6); unset raises
geometric_mean_radius Optional[float] 0.0111, 0.0158 copied OverheadWireInfo.gmr ({unit}); unset raises
rating_summer_continuous Optional[float] copied OverheadWireInfo.ratedCurrent (A); also the normal CurrentLimit of the wire's AssetInfo OperationalLimitSet _limits. Unset: GridLAB-D's create() constant is not filled (S2-7)
rating_summer_emergency Optional[float] structural the emergency CurrentLimit of that set; unset: not filled (S2-7)
rating_winter_continuous Optional[float] untranscribed equal to summer in every deck that sets it; a different value raises (no season is mapped, S2-7)
rating_winter_emergency Optional[float] untranscribed equal to summer in every deck that sets it; a different value raises (no season is mapped, S2-7)

line_spacing

LineSpacing field type samples kind target
name Union[str, LineSpacingName] spc_510_CN, spc_601_ABCN, spc_602_ABCN copied ConductorDistanceSpacing.name; mRID = spc_ + name; isTemplate = true
parent Optional[str] untranscribed object header: a catalog object has no place or service state
groupid Optional[str] untranscribed object header: a catalog object has no place or service state
latitude Optional[str] untranscribed object header: a catalog object has no place or service state
longitude Optional[str] untranscribed object header: a catalog object has no place or service state
in_svc Optional[str] untranscribed object header: a catalog object has no place or service state
out_svc Optional[str] untranscribed object header: a catalog object has no place or service state
rank Optional[str] untranscribed object header: a catalog object has no place or service state
flags Optional[str] untranscribed object header: a catalog object has no place or service state
distance_AB Optional[float] 3.0, 0.5, 2.5 structural one ConductorDistance, distance in the written unit; ends numbered 1..n over the spacing's phases (S2-3), fromPhase/toPhase the letters. Unset or 0: no row (S2-4)
distance_BC Optional[float] 4.0, 7.0, 0.5 structural one ConductorDistance, distance in the written unit; ends numbered 1..n over the spacing's phases (S2-3), fromPhase/toPhase the letters. Unset or 0: no row (S2-4)
distance_AC Optional[float] 7.0, 1.0, 4.5 structural one ConductorDistance, distance in the written unit; ends numbered 1..n over the spacing's phases (S2-3), fromPhase/toPhase the letters. Unset or 0: no row (S2-4)
distance_AN Optional[float] 5.6569, 0.25, 4.272002 structural one ConductorDistance, distance in the written unit; ends numbered 1..n over the spacing's phases (S2-3), fromPhase/toPhase the letters. Unset or 0: no row (S2-4)
distance_BN Optional[float] 4.1231, 5.0, 5.656854 structural one ConductorDistance, distance in the written unit; ends numbered 1..n over the spacing's phases (S2-3), fromPhase/toPhase the letters. Unset or 0: no row (S2-4)
distance_CN Optional[float] 5.0249, 5.0, 5.6569 structural one ConductorDistance, distance in the written unit; ends numbered 1..n over the spacing's phases (S2-3), fromPhase/toPhase the letters. Unset or 0: no row (S2-4)
distance_AE Optional[float] 28.0, -4.0 structural the conductor's height: a ConductorDistance to a position of kind earth, no second sequence number or phase. Unset or 0: no row (S2-4)
distance_BE Optional[float] 28.0, -4.0 structural the conductor's height: a ConductorDistance to a position of kind earth, no second sequence number or phase. Unset or 0: no row (S2-4)
distance_CE Optional[float] 29.0, 28.0, -4.0 structural the conductor's height: a ConductorDistance to a position of kind earth, no second sequence number or phase. Unset or 0: no row (S2-4)
distance_NE Optional[float] 24.0, -4.0 structural the conductor's height: a ConductorDistance to a position of kind earth, no second sequence number or phase. Unset or 0: no row (S2-4)

line_configuration

LineConfiguration field type samples kind target
name Union[str, LineConfigurationName] lcon_mtx601_ABC, lcon_mtx602_ABC, lcon_mtx603_CB copied WireConfiguration.name, PerLengthPhaseImpedance.name; mRID = wc_ or lc_ + name; a matrix's WireConfiguration lc__wc
parent Optional[str] untranscribed object header: a catalog object has no place or service state
groupid Optional[str] untranscribed object header: a catalog object has no place or service state
latitude Optional[str] untranscribed object header: a catalog object has no place or service state
longitude Optional[str] untranscribed object header: a catalog object has no place or service state
in_svc Optional[str] untranscribed object header: a catalog object has no place or service state
out_svc Optional[str] untranscribed object header: a catalog object has no place or service state
rank Optional[str] untranscribed object header: a catalog object has no place or service state
flags Optional[str] untranscribed object header: a catalog object has no place or service state
conductor_A Optional[str] wire_acsr_556_5, wire_acsr_4/0, wire_acsr_1/0 structural geometry: one WireSequenceConfiguration, sequenceNumber 1..n in ABCN order (S2-3), WireInfo = the conductor's mRID; numberOfPhases = the A, B, C conductors set
conductor_B Optional[str] wire_acsr_556_5, wire_acsr_4/0, wire_acsr_1/0 structural geometry: one WireSequenceConfiguration, sequenceNumber 1..n in ABCN order (S2-3), WireInfo = the conductor's mRID; numberOfPhases = the A, B, C conductors set
conductor_C Optional[str] wire_acsr_1/0, wire_acsr_556_5, wire_acsr_4/0 structural geometry: one WireSequenceConfiguration, sequenceNumber 1..n in ABCN order (S2-3), WireInfo = the conductor's mRID; numberOfPhases = the A, B, C conductors set
conductor_N Optional[str] wire_acsr_1/0, wire_acsr_4/0, ugwire_cu_1/0 structural geometry: one WireSequenceConfiguration, sequenceNumber 1..n in ABCN order (S2-3), WireInfo = the conductor's mRID; numberOfPhases = the A, B, C conductors set
spacing Optional[str] spc_510_CN, spc_601_ABCN, spc_602_ABCN structural geometry: WireConfiguration.WireSpacing = spc_ + spacing
z11 Union[dict, Complex, NoneType] Complex({'real': 0.3465, 'imag': 1.01..., Complex({'real': 0.7526, 'imag': 1.18..., Complex({'real': 1.3238, 'imag': 1.35... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
z12 Union[dict, Complex, NoneType] Complex({'real': 0.1535, 'imag': 0.38..., Complex({'real': 0.318476, 'imag': 0...., Complex({'real': 0.5198, 'imag': 0.27... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
z13 Union[dict, Complex, NoneType] Complex({'real': 0.158, 'imag': 0.4236}), Complex({'real': 0.156, 'imag': 0.5017}), Complex({'real': 0.2066, 'imag': 0.45... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
z21 Union[dict, Complex, NoneType] Complex({'real': 0.1535, 'imag': 0.38..., Complex({'real': 0.318476, 'imag': 0...., Complex({'real': 0.5198, 'imag': 0.27... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
z22 Union[dict, Complex, NoneType] Complex({'real': 0.3375, 'imag': 1.04..., Complex({'real': 0.7475, 'imag': 1.19..., Complex({'real': 1.3294, 'imag': 1.34... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
z23 Union[dict, Complex, NoneType] Complex({'real': 0.156, 'imag': 0.5017}), Complex({'real': 0.158, 'imag': 0.4236}), Complex({'real': 0.2066, 'imag': 0.45... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
z31 Union[dict, Complex, NoneType] Complex({'real': 0.158, 'imag': 0.4236}), Complex({'real': 0.156, 'imag': 0.5017}), Complex({'real': 0.2066, 'imag': 0.45... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
z32 Union[dict, Complex, NoneType] Complex({'real': 0.156, 'imag': 0.5017}), Complex({'real': 0.158, 'imag': 0.4236}), Complex({'real': 0.2066, 'imag': 0.45... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
z33 Union[dict, Complex, NoneType] Complex({'real': 0.3414, 'imag': 1.03..., Complex({'real': 0.7436, 'imag': 1.21..., Complex({'real': 1.3238, 'imag': 1.35... structural matrix: one PhaseImpedanceData per lower-triangle element, r and x the real and imaginary parts; rows and columns compacted in ABC order; z_ij must equal z_ji
c11 Optional[float] 0.0, 383.948, 236.0 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
c12 Optional[float] 0.0, -4.8592, -3.0889 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
c13 Optional[float] 0.0, -1.852, -4.8592 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
c21 Optional[float] 0.0, -4.8592, -3.0889 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
c22 Optional[float] 0.0, 383.948, 2.8 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
c23 Optional[float] 0.0, -0.6, -3.0889 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
c31 Optional[float] 0.0, -1.852, -4.8592 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
c32 Optional[float] 0.0, -0.6, -3.0889 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
c33 Optional[float] 0.0, 383.948, 2.8 derived matrix: PhaseImpedanceData b = 2 pi f c (b_from_c), nF gives nS, f the base frequency (also calculatedFrequency). Unset with its z set: GridLAB-D's 0, defaulted
rating_summer_continuous Optional[float] structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet
rating_summer_emergency Optional[float] structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet
rating_winter_continuous Optional[float] structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet
rating_winter_emergency Optional[float] structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet

triplex_line_configuration

TriplexLineConfiguration field type samples kind target
name Union[str, TriplexLineConfigurationName] triplex_line_configuration_1, triplex_line_configuration:1 copied WireConfiguration.name; mRID = wc_ + name; its spacing wc__spc
parent Optional[str] untranscribed object header: a catalog object has no place or service state
groupid Optional[str] untranscribed object header: a catalog object has no place or service state
latitude Optional[str] untranscribed object header: a catalog object has no place or service state
longitude Optional[str] untranscribed object header: a catalog object has no place or service state
in_svc Optional[str] untranscribed object header: a catalog object has no place or service state
out_svc Optional[str] untranscribed object header: a catalog object has no place or service state
rank Optional[str] untranscribed object header: a catalog object has no place or service state
flags Optional[str] untranscribed object header: a catalog object has no place or service state
conductor_A Optional[str] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
conductor_B Optional[str] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
conductor_C Optional[str] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
conductor_N Optional[str] tp_line_conductor, triplex_4/0 AA structural geometry: WireSequenceConfiguration 3 (spacing phase N; GridLAB-D keeps it in its phase C slot); required
spacing Optional[str] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
z11 Union[dict, Complex, NoneType] structural matrix: one PhaseImpedanceData per lower-triangle element on s1, s2, r and x the real and imaginary parts, b 0 (no shunt admittance); z11 and z22 required, z12 must equal z21
z12 Union[dict, Complex, NoneType] structural matrix: one PhaseImpedanceData per lower-triangle element on s1, s2, r and x the real and imaginary parts, b 0 (no shunt admittance); z11 and z22 required, z12 must equal z21
z13 Union[dict, Complex, NoneType] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
z21 Union[dict, Complex, NoneType] structural matrix: one PhaseImpedanceData per lower-triangle element on s1, s2, r and x the real and imaginary parts, b 0 (no shunt admittance); z11 and z22 required, z12 must equal z21
z22 Union[dict, Complex, NoneType] structural matrix: one PhaseImpedanceData per lower-triangle element on s1, s2, r and x the real and imaginary parts, b 0 (no shunt admittance); z11 and z22 required, z12 must equal z21
z23 Union[dict, Complex, NoneType] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
z31 Union[dict, Complex, NoneType] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
z32 Union[dict, Complex, NoneType] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
z33 Union[dict, Complex, NoneType] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c11 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c12 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c13 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c21 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c22 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c23 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c31 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c32 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
c33 Optional[float] structural inherited from line_configuration and not read by GridLAB-D's triplex line: set raises
rating_summer_continuous Optional[float] structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet
rating_summer_emergency Optional[float] structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet
rating_winter_continuous Optional[float] structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet
rating_winter_emergency Optional[float] structural not on the template (D9): the S3a line mapper puts it on each line's own OperationalLimitSet
conductor_1 Optional[str] tp_line_conductor, triplex_4/0 AA structural geometry: WireSequenceConfiguration 1 (spacing phase s1); required
conductor_2 Optional[str] tp_line_conductor, triplex_4/0 AA structural geometry: WireSequenceConfiguration 2 (spacing phase s2); required
insulation_thickness Optional[float] 0.08 derived see diameter
diameter Optional[float] 0.368, 0.522 derived the spacing's distances (triplex_spacing): D12 = diameter + 2 insulation_thickness, D1N = D2N = diameter + insulation_thickness

S3a: lines and switches (approved 2026-11-09)

S3a maps the branches that are not transformers or regulators: the three line classes and the switching devices, six artifacts, one per native table (D4), in the plan's section 2 order (rows 8 and 9). Counts are from the 28 readable decks (IEEE123_transactive stops at read); samples from the decks named. GridLAB-D citations are to the C++ source (powerflow/).

# artifact native class (records) CIM mRID
8 overhead_line.cimtbl overhead_line (7,306) ACLineSegment: by WireConfiguration (7,176) or PerLengthPhaseImpedance (130) ln_<name>
8 underground_line.cimtbl underground_line (4,278) ACLineSegment by WireConfiguration (4,245 CN, 33 TS) ln_<name>
8 triplex_line.cimtbl triplex_line (7,507) ACLineSegment by WireConfiguration, phases s1s2N ln_<name>
9 switch.cimtbl switch (580) LoadBreakSwitch sw_<name>
9 fuse.cimtbl fuse (1,599) Fuse sw_<name>
9 recloser.cimtbl recloser (35) Recloser sw_<name>
9 sectionalizer.cimtbl sectionalizer (0) Sectionaliser sw_<name>

Shapes: line_by_wire_configuration, line_by_impedance (ratings on the instance), switch. No shape change.

Identity (S3a-1): prefix + the GLM name in source case, as S2. The three line classes share ln_ and the switching devices share sw_ (the switch shape's rule, so a class change keeps the mRID); GLM names are unique across a model, so nothing collides. Limits: <mRID>_limits, <mRID>_norm, <mRID>_emerg, as DSS.

Ends: node1 = from, node2 = to, each the root bus of its object (GLM-4): 30 lines and switches start on a child node (15 underground lines, 10 switches, 4 overhead lines, 1 recloser), which GridLAB-D solves as its root. BaseVoltage is the walk's at node1; EquipmentContainer the feeder.

Lines

# IEEE13_cdpsm: a matrix configuration; GLM phases are a set, so CB is written in ABC order
Table ACLineSegment: mRID, name, node1, node2, phases, length (ft), WireConfiguration, BaseVoltage, EquipmentContainer=fdr_IEEE13_cdpsm
    ln_line_632645, line_632645, 632, 645, BC, 500.0, lc_lcon_mtx603_CB_wc, bv_4p16kv
Table OperationalLimitSet: mRID, Equipment
    ln_line_632645_limits, ln_line_632645
Table CurrentLimit: mRID, normalValue (A), OperationalLimitType, OperationalLimitSet
    ln_line_632645_norm,  230.0, olt_normal,    ln_line_632645_limits
    ln_line_632645_emerg, 600.0, olt_emergency, ln_line_632645_limits

# orig_R1-12.47-3: geometry; ACLineSegmentPhase A, C, N are 1, 2, 3, the positions of its spacing (S2-3)
Table ACLineSegment: mRID, name, node1, node2, phases, length (ft), WireConfiguration, BaseVoltage, EquipmentContainer=fdr_orig_R1-12.47-3
    ln_R1-12-47-3_ol_2, R1-12-47-3_ol_2, R1-12-47-3_node_4, R1-12-47-3_node_5, ACN, 68.936, wc_line_configuration:19, bv_12p47kv

# triplex: s1, s2, N are 1, 2, 3, the derived spacing's positions (S2-8)
    ln_R1-12-47-3_tl_1, R1-12-47-3_tl_1, R1-12-47-3_tn_1, R1-12-47-3_tm_1, s1s2N, 30.0, wc_triplex_line_configuration:1, bv_240v  # phases BS
GLM slot kind target
name copied ACLineSegment.name; mRID = ln_ + name
from, to structural node1, node2: the root bus (GLM-4)
phases structural the phases cell, which numbers the ACLineSegmentPhases 1..n in written order (S3a-3)
configuration structural WireConfiguration = wc_<configuration> (geometry, triplex) or lc_<configuration>_wc (matrix: the WireConfiguration that holds the template PerLengthPhaseImpedance), by the configuration's form (S2-9, S3a-2)
length copied length, in its written unit (ft in every deck); unset raises (GridLAB-D's create() 0 is a line of no impedance)
continuous_rating_A/_B/_C structural the normal CurrentLimit of the line's own OperationalLimitSet (S3a-4)
emergency_rating_A/_B/_C structural the emergency CurrentLimit of that set
status structural unset or CLOSED; OPEN raises (a line is not a switch; the walk already raises)
nominal_voltage untranscribed the walk gives the BaseVoltage (GLM-1); no deck sets it on a link
mean_repair_time untranscribed reliability data
power_*, current_*, fault_*, overloaded_status, flow_direction, triplex_neutral_*_value, condition, solution untranscribed solver outputs and state
pdispatch, pdispatch_offset, set_pdispatch untranscribed dispatch control, no network-profile home
inrush_* untranscribed inrush solver settings
object header (parent, groupid, latitude, longitude, in_svc, out_svc, rank, flags) untranscribed no deck sets them on a link; listed per row when set

Switches, fuses, reclosers, sectionalizers

# IEEE123: a balanced 3-phase device leaves phases blank (shape switch); GLM has one state, so normalOpen = open
Table LoadBreakSwitch: mRID, name, node1, node2, phases, open, normalOpen, BaseVoltage, EquipmentContainer=fdr_IEEE123
    sw_swt_sw7, swt_sw7, 151, 300, , true, true, bv_4p16kv
    sw_swt_sw8, swt_sw8, 54,  94,  A, true, true, bv_4p16kv
# IEEE13_cdpsm
Table Fuse: mRID, name, node1, node2, phases, ratedCurrent (A), open, normalOpen, BaseVoltage, EquipmentContainer=fdr_IEEE13_cdpsm
    sw_swt_fuse1, swt_fuse1, 633, xf1, , 100.0, false, false, bv_4p16kv
GLM slot kind target
name, from, to copied, structural as lines; mRID = sw_ + name
phases structural the phase conductors, N dropped (S3a-7); ABC blank (phases_cell)
status structural open and normalOpen (OPEN = true), S3a-6
phase_A_state/_B_/_C_ (switch, recloser) structural on the device's phases must equal status, else raises (S3a-6); on a phase it lacks, untranscribed (the recloser default CLOSED the taxonomy writes on all three)
operating_mode untranscribed with every phase state equal to status, BANKED and INDIVIDUAL operate the same (switch_object.cpp:308)
phase_A_status/_B_/_C_ (fuse) structural unset or GOOD; BLOWN raises (S3a-6); no deck sets them
current_limit (fuse) copied Fuse.ratedCurrent (A) (S3a-8); unset: GridLAB-D's 9999 A (fuse.cpp:119, "big current") is not filled, and the row says so
continuous_rating_X, emergency_rating_X structural the device's own OperationalLimitSet, as lines (S3a-5)
switch_resistance, switch_reactance, switch_impedance, fuse_resistance untranscribed GridLAB-D's numerical stand-in for a closed device (as DSS-8); none set
mean_replacement_time, repair_dist_type (fuse), mean_repair_time untranscribed reliability data
retry_time, max_number_of_tries (recloser) untranscribed protection settings; home RecloseSequence, which waits for the protection model as DSS-11 (U15)
number_of_tries (recloser) untranscribed state
the link outputs, dispatch, inrush and header slots untranscribed as lines

Fail fast (S3a)

condition why
a line without configuration or length, or with a configuration of the wrong class (a triplex configuration on an overhead line) overhead_line.cpp:96, :103 throw
an overhead line on underground conductors or the reverse; an underground line whose phase cables are not one kind overhead_line.cpp:923, underground_line.cpp:149 throw; none in the decks
a geometry line whose phases are not its configuration's conductors (ACN on an A C N configuration), or a matrix line whose phases are not its diagonal the positions must agree (S2-3); GridLAB-D throws on a missing conductor (test_phases). All 11,584 agree
D on any line, S on a non-triplex line, a triplex line not AS/BS/CS, or a triplex line whose ends the walk does not put on a split-phase system none in the decks
per-phase ratings that differ; a line's own rating and its configuration's that differ one limit set per line; none in the decks
a switch or recloser phase state that differs from status on a phase it has; a BLOWN fuse phase per-phase state needs SwitchPhase rows; none in the decks (S3a-6)
status OPEN on a line, an end that is no bus object the walk raises (S0)

Decisions for S3a

# question decision
S3a-1 Files and identity approved: The six artifacts above; ln_ for every line class, sw_ for every switching device, source case
S3a-2 Line template approved: The configuration's form decides (S2-9): geometry and triplex give their WireConfiguration, a matrix the WireConfiguration lc_<configuration>_wc that holds its template PerLengthPhaseImpedance (isTemplate=true, no WireSpacing; amended 2026-11-21, the user's rule, skill wire-configuration). The line class must match its conductors' class (GridLAB-D throws otherwise); all decks do
S3a-3 Line phases approved: The line's letters in ABC order then N (GLM phases is a set: CB is BC, so matrix row 1 is B, as S2-9 compacts it). It must equal the configuration's conductors (geometry) or diagonal (matrix), so ACLineSegmentPhase k is spacing position k. A triplex line is s1s2N whatever its letter (AS, BS, CS): CIM puts the primary phase on the center-tap transformer (S3b); the letter must match its end buses'. Amended by S6-4: a matrix line's N is dropped (GridLAB-D's matrix never reads it), and a written 0 diagonal is no phase
S3a-4 Line ratings approved: The line's own continuous_rating_X/emergency_rating_X, as written, on its own OperationalLimitSet (D9); else its configuration's rating.summer.* (only triplex_line_configuration:1 of orig_R5-35.00-1, 1200 A, 192 lines); else none. Conductor ratings stay on the WireInfo (S2-7) and are not copied, and GridLAB-D's 1000/2000 A defaults are never filled. Only the three Java exports rate lines (140 lines, always equal across phases). Note: GridLAB-D itself replaces a line's written ratings at init, with its conductors' (a running minimum over A, B, C) or, on a matrix configuration, the configuration's (overhead_line.cpp:133). The written values are the deck's statement (the Java exports wrote the CIM source's line limits: IEEE13_assets 730/1095 A on 730/730 A conductors), so they are kept. The alternative is to write the engine's effective rating and leave the written ones untranscribed
S3a-5 Switch ratings approved: The same rule as lines: the device's own set (IEEE13_cdpsm, IEEE13_assets, IEEE123: 400/600 A on 12 switches, the fuse and the recloser). GridLAB-D reads no rating on a switch (link.cpp:681 checks limits on lines and transformers only), and the DSS import drops a switch's ratings as stand-ins (DSS-8), so the alternative is untranscribed
S3a-6 Switch state approved: status gives open, and normalOpen the same (GLM has one state; DSS's rule when no Normal is given). Per-phase states that differ raise instead of writing SwitchPhase rows: no deck has one (every recloser writes CLOSED on all three, status CLOSED), so plan section 7's core switch per-phase dependency is dropped until a deck needs it. 2 switches are open (IEEE123 swt_sw7, swt_sw8)
S3a-7 Switch phases approved: The phase conductors, N dropped: GridLAB-D's switch, fuse and recloser have no neutral element, and CIM's SwitchPhase is a switched conductor (the DSS import writes none). 568 of 580 switches and 1,598 of 1,599 fuses write N
S3a-8 Fuse rating approved: current_limit copied to ratedCurrent as written: 1,598 taxonomy fuses write 50000 A (// 10000 in a trailing comment), a fuse that never blows; IEEE13_cdpsm's is 100 A, as the DSS import
S3a-9 Recloser approved: Recloser; its reclosing settings untranscribed until the protection model lands (DSS-11, U15)
S3a-10 Sectionalizer (GLM-10, amended 2026-11-24) approved: Sectionaliser, which cim18v17 has as a Switch. A GLM sectionalizer adds no slots to switch, so it maps as one: the switch table's fields, the same rules (S3a-5 to S3a-7). No deck has one; the line atom does. (Before 2026-11-24 it was not mapped, which split the network at it: the walk crosses it as a branch.)
S3a-11 Field tables approved: Generated from the mappers' FIELDS with fields_table once built, as S2-10

Expected differences from the DSS import of IEEE13 (GLM-16): mRIDs and names carry the Java prefixes (ln_line_632645, sw_swt_fuse1 vs ln_632645, sw_fuse1), so the comparison matches by connected nodes. The CB lines are BC (DSS writes bus order, 645.3.2): the same impedance per phase in another row order. The lines carry an emergency limit (600 A, DSS's default emergamps the Java export wrote), which the DSS import does not fill. With S3a-5, the switches carry 400/600 A limits that the DSS import drops. swt_brkr1 is a LoadBreakSwitch in both (the Java export's // CIM Breaker is a comment, which the reader does not keep).

Built (2026-11-09)

  • importer/cimtbl/link.py (the link slots and their untranscribed groups, classify, ends, link_ratings, Limits), line.py (map_lines, LINES), switch.py (map_switches, SWITCHES), wired into MAPPING_ORDER and CLASSIFIED. configuration.py gains conductor_letters, diagonal_letters, is_matrix and template, which the line mapper reads.
  • The schema derives triplex_line_configuration from line_configuration, so a line's configuration class is checked exactly (a triplex configuration on an overhead line raises, as overhead_line.cpp:103).
  • The S1 atoms' line l1 now has a configuration (a 3-phase matrix) and phases ABC: GridLAB-D needs one, and S3a maps the line. Their bus and source goldens are unchanged.
  • Atom tests/atoms/line/line.glm (on the S2 catalog atom by #include: a matrix line written CA, a taxonomy geometry line in metres, an underground line from a child node, two triplex lines, one on a rated configuration, a switch with N and ratings, an open switch, a fuse with and without current_limit, a 1-phase recloser with three phase states, a sectionalizer) with one golden per part; goldens tests/goldens/IEEE13_cdpsm/overhead_line, switch, fuse, recloser; tests/test_cimtbl_line.py (classification, the atom bound and read back, 11 fail-fast cases, and a sweep that counts every line and switching device and checks, on every geometry line, that ACLineSegmentPhase k is its spacing's position k).
  • Every deck that binds S2 binds S3a: 27 of 29, the same two deck defects; 19,091 segments, 580 switches, 1,599 fuses, 35 reclosers.

Field tables (generated: fields_table(cls, records, fields=...), samples from tests/decks and the atom)

Every link class also has these untranscribed groups, left out of the tables: the object header (parent, groupid, latitude, longitude, in_svc, out_svc, rank, flags; no deck sets them on a link), solver outputs and state (power_*, current_* but current_limit, fault_*, overloaded_status, flow_direction, triplex_neutral_*_value, condition, solution) and inrush solver settings (inrush_*).

overhead_line

OverheadLine field type samples kind target
name Union[str, OverheadLineName] line_632633, line_632645, line_632670 copied ACLineSegment.name; mRID = ln_ + name
phases Optional[str] ABC, CB, AC structural the phases cell: ABC then N, equal to the configuration's conductors (geometry) or diagonal (matrix); s1s2N on a triplex line, s1s2 on a triplex matrix (S3a-3)
nominal_voltage Optional[float] untranscribed the walk gives the BaseVoltage (GLM-1)
status Optional[str] structural unset or CLOSED; OPEN raises (the walk: a line is not a switch)
from_node Optional[str] 632, mid, 645 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] 633, 645, 670 structural node2: the root bus of the object it names (GLM-4)
pdispatch Optional[float] untranscribed dispatch control; no network-profile home
pdispatch_offset Optional[float] untranscribed dispatch control; no network-profile home
set_pdispatch Union[bool, Bool, NoneType] untranscribed dispatch control; no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
continuous_rating_A Optional[float] 340.0, 730.0, 230.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_B Optional[float] 340.0, 230.0, 730.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_C Optional[float] 340.0, 230.0, 730.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
emergency_rating_A Optional[float] 600.0, 730.0, 510.0 structural the emergency CurrentLimit of that set
emergency_rating_B Optional[float] 600.0, 730.0, 510.0 structural the emergency CurrentLimit of that set
emergency_rating_C Optional[float] 600.0, 730.0, 510.0 structural the emergency CurrentLimit of that set
configuration Optional[str] lcon_mtx602_ABC, lcon_mtx603_CB, lcon_mtx601_ABC structural WireConfiguration = wc_ (geometry) or lc__wc (matrix: the WireConfiguration that holds the template PerLengthPhaseImpedance), S3a-2
length Optional[float] 500.0, 667.0, 300.0 copied ACLineSegment.length ({unit}); in its written unit; unset raises

underground_line

UndergroundLine field type samples kind target
name Union[str, UndergroundLineName] line_684652, line_692675, GC-12-47-1_ul_1 copied ACLineSegment.name; mRID = ln_ + name
phases Optional[str] AN, ABC, ABCN structural the phases cell: ABC then N, equal to the configuration's conductors (geometry) or diagonal (matrix); s1s2N on a triplex line, s1s2 on a triplex matrix (S3a-3)
nominal_voltage Optional[float] untranscribed the walk gives the BaseVoltage (GLM-1)
status Optional[str] structural unset or CLOSED; OPEN raises (the walk: a line is not a switch)
from_node Optional[str] 684, 692, GC-12-47-1_node_5 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] 652, 675, GC-12-47-1_node_6 structural node2: the root bus of the object it names (GLM-4)
pdispatch Optional[float] untranscribed dispatch control; no network-profile home
pdispatch_offset Optional[float] untranscribed dispatch control; no network-profile home
set_pdispatch Union[bool, Bool, NoneType] untranscribed dispatch control; no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
continuous_rating_A Optional[float] 165.0, 260.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_B Optional[float] 260.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_C Optional[float] 260.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
emergency_rating_A Optional[float] 247.5, 390.0 structural the emergency CurrentLimit of that set
emergency_rating_B Optional[float] 390.0 structural the emergency CurrentLimit of that set
emergency_rating_C Optional[float] 390.0 structural the emergency CurrentLimit of that set
configuration Optional[str] lcon_607_4, lcon_606_0, line_configuration:6 structural WireConfiguration = wc_ (geometry) or lc__wc (matrix: the WireConfiguration that holds the template PerLengthPhaseImpedance), S3a-2
length Optional[float] 800.0, 500.0, 340.889 copied ACLineSegment.length ({unit}); in its written unit; unset raises

triplex_line

TriplexLine field type samples kind target
name Union[str, TriplexLineName] R1-12-47-3_tl_1, tl_1, tl_2 copied ACLineSegment.name; mRID = ln_ + name
phases Optional[str] BS, AS structural the phases cell: ABC then N, equal to the configuration's conductors (geometry) or diagonal (matrix); s1s2N on a triplex line, s1s2 on a triplex matrix (S3a-3)
nominal_voltage Optional[float] untranscribed the walk gives the BaseVoltage (GLM-1)
status Optional[str] structural unset or CLOSED; OPEN raises (the walk: a line is not a switch)
from_node Optional[str] R1-12-47-3_tn_1, tn1 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] R1-12-47-3_tm_1, tm1, tm2 structural node2: the root bus of the object it names (GLM-4)
pdispatch Optional[float] untranscribed dispatch control; no network-profile home
pdispatch_offset Optional[float] untranscribed dispatch control; no network-profile home
set_pdispatch Union[bool, Bool, NoneType] untranscribed dispatch control; no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
continuous_rating_A Optional[float] structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_B Optional[float] structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_C Optional[float] structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
emergency_rating_A Optional[float] structural the emergency CurrentLimit of that set
emergency_rating_B Optional[float] structural the emergency CurrentLimit of that set
emergency_rating_C Optional[float] structural the emergency CurrentLimit of that set
configuration Optional[str] triplex_line_configuration:1, tc_rated structural WireConfiguration = wc_ (geometry) or lc__wc (matrix: the WireConfiguration that holds the template PerLengthPhaseImpedance), S3a-2
length Optional[float] 30.0 copied ACLineSegment.length ({unit}); in its written unit; unset raises

switch

Switch field type samples kind target
name Union[str, SwitchName] swt_671692, swt_brkr1, swt_sect1 copied LoadBreakSwitch.name; mRID = sw_ + name
phases Optional[str] ABC, C, A structural the switched conductors A, B, C, N dropped; ABC is blank (S3a-7)
nominal_voltage Optional[float] untranscribed the walk gives the BaseVoltage (GLM-1)
status Optional[str] CLOSED, OPEN structural open and normalOpen (OPEN = true); unset: GridLAB-D's CLOSED, defaulted (S3a-6)
from_node Optional[str] 671, 650, 684 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] 692, brkr, tap structural node2: the root bus of the object it names (GLM-4)
pdispatch Optional[float] untranscribed dispatch control; no network-profile home
pdispatch_offset Optional[float] untranscribed dispatch control; no network-profile home
set_pdispatch Union[bool, Bool, NoneType] untranscribed dispatch control; no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
continuous_rating_A Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_B Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_C Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
emergency_rating_A Optional[float] 600.0 structural the emergency CurrentLimit of that set
emergency_rating_B Optional[float] 600.0 structural the emergency CurrentLimit of that set
emergency_rating_C Optional[float] 600.0 structural the emergency CurrentLimit of that set
phase_A_state Optional[str] structural on the device's phases must equal status, else raises (S3a-6); on a phase it lacks, listed on the row
phase_B_state Optional[str] structural on the device's phases must equal status, else raises (S3a-6); on a phase it lacks, listed on the row
phase_C_state Optional[str] structural on the device's phases must equal status, else raises (S3a-6); on a phase it lacks, listed on the row
operating_mode Optional[str] untranscribed with every phase state equal to status, BANKED and INDIVIDUAL operate the same (switch_object.cpp:308)
switch_impedance Union[dict, Complex, NoneType] untranscribed GridLAB-D's numerical stand-in for a closed device (as DSS-8)
switch_resistance Optional[float] untranscribed GridLAB-D's numerical stand-in for a closed device (as DSS-8)
switch_reactance Optional[float] untranscribed GridLAB-D's numerical stand-in for a closed device (as DSS-8)

fuse

Fuse field type samples kind target
name Union[str, FuseName] swt_fuse1, GC-12-47-1_fuse_1, GC-12-47-1_fuse_2 copied Fuse.name; mRID = sw_ + name
phases Optional[str] ABC, ABCN, AN structural the switched conductors A, B, C, N dropped; ABC is blank (S3a-7)
nominal_voltage Optional[float] untranscribed the walk gives the BaseVoltage (GLM-1)
status Optional[str] CLOSED structural open and normalOpen (OPEN = true); unset: GridLAB-D's CLOSED, defaulted (S3a-6)
from_node Optional[str] 633, GC-12-47-1_node_11, GC-12-47-1_node_16 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] xf1, GC-12-47-1_node_12, GC-12-47-1_node_15 structural node2: the root bus of the object it names (GLM-4)
pdispatch Optional[float] untranscribed dispatch control; no network-profile home
pdispatch_offset Optional[float] untranscribed dispatch control; no network-profile home
set_pdispatch Union[bool, Bool, NoneType] untranscribed dispatch control; no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
continuous_rating_A Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_B Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_C Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
emergency_rating_A Optional[float] 600.0 structural the emergency CurrentLimit of that set
emergency_rating_B Optional[float] 600.0 structural the emergency CurrentLimit of that set
emergency_rating_C Optional[float] 600.0 structural the emergency CurrentLimit of that set
phase_A_status Optional[str] structural unset or GOOD; BLOWN raises on a phase the fuse has (S3a-6)
phase_B_status Optional[str] structural unset or GOOD; BLOWN raises on a phase the fuse has (S3a-6)
phase_C_status Optional[str] structural unset or GOOD; BLOWN raises on a phase the fuse has (S3a-6)
repair_dist_type Optional[str] untranscribed reliability data
current_limit Optional[float] 100.0, 50000.0 copied Fuse.ratedCurrent ({unit}); S3a-8; unset: GridLAB-D's 9999 A (fuse.cpp:119) is not filled, the row says so
mean_replacement_time Optional[float] 3600.0, 1000.0 untranscribed reliability data
fuse_resistance Optional[float] untranscribed GridLAB-D's numerical stand-in for a closed device (as DSS-8)

recloser

Recloser field type samples kind target
name Union[str, RecloserName] swt_rec1, recloser_1 copied Recloser.name; mRID = sw_ + name
phases Optional[str] ABC, CN structural the switched conductors A, B, C, N dropped; ABC is blank (S3a-7)
nominal_voltage Optional[float] untranscribed the walk gives the BaseVoltage (GLM-1)
status Optional[str] CLOSED structural open and normalOpen (OPEN = true); unset: GridLAB-D's CLOSED, defaulted (S3a-6)
from_node Optional[str] 632, n1 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] mid, n10 structural node2: the root bus of the object it names (GLM-4)
pdispatch Optional[float] untranscribed dispatch control; no network-profile home
pdispatch_offset Optional[float] untranscribed dispatch control; no network-profile home
set_pdispatch Union[bool, Bool, NoneType] untranscribed dispatch control; no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
continuous_rating_A Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_B Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_C Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
emergency_rating_A Optional[float] 600.0 structural the emergency CurrentLimit of that set
emergency_rating_B Optional[float] 600.0 structural the emergency CurrentLimit of that set
emergency_rating_C Optional[float] 600.0 structural the emergency CurrentLimit of that set
phase_A_state Optional[str] CLOSED structural on the device's phases must equal status, else raises (S3a-6); on a phase it lacks, listed on the row
phase_B_state Optional[str] CLOSED structural on the device's phases must equal status, else raises (S3a-6); on a phase it lacks, listed on the row
phase_C_state Optional[str] CLOSED structural on the device's phases must equal status, else raises (S3a-6); on a phase it lacks, listed on the row
operating_mode Optional[str] INDIVIDUAL untranscribed with every phase state equal to status, BANKED and INDIVIDUAL operate the same (switch_object.cpp:308)
switch_impedance Union[dict, Complex, NoneType] untranscribed GridLAB-D's numerical stand-in for a closed device (as DSS-8)
switch_resistance Optional[float] untranscribed GridLAB-D's numerical stand-in for a closed device (as DSS-8)
switch_reactance Optional[float] untranscribed GridLAB-D's numerical stand-in for a closed device (as DSS-8)
retry_time Optional[float] 1.0 untranscribed protection setting; home RecloseSequence, which waits for the protection model (DSS-11, U15)
max_number_of_tries Optional[float] 3.0 untranscribed protection setting; see retry_time
number_of_tries Optional[float] 0.0 untranscribed state

sectionalizer

A sectionalizer is a switch with no slots of its own: every field is the switch table's, classified the same (switch.SECTIONALIZER_FIELDS), and the row is Sectionaliser's, mRID sw_<name>.

S3b: transformers (approved 2026-11-09 with the user's S3b-1, -4, -5, -9; built 2026-11-09)

S3b maps transformer_configuration to templates and transformer to instances by template (GLM-6), in plan section 2 rows 5 and 10. Counts are from the 28 readable decks: 1,469 configurations, 1,459 of them used, and 8,943 transformers. GridLAB-D citations are to powerflow/transformer.cpp and transformer_configuration.cpp.

# artifact native class (records) CIM mRID
5 transformer_configuration.cimtbl transformer_configuration (1,469) TransformerTankConfiguration: by TransformerTankEnd (a three-phase tank), by TransformerLug (a center tap, a one-phase can, and each can of a bank), and TransformerBankConfiguration over a bank's cans xc_<name>, xb_<name>
10 transformer.cimtbl transformer (8,943) PowerTransformer + its TransformerTanks by template + a PowerTransformerEnd per side xf_<name>

Shapes: transformer_template, transformer_template_1ph, transformer_by_template, and the CIMTBL-Models bank (distribution/templates/bank_oyod_50_50_7200_12470y.cimtbl). No shape change: the impedance is the configuration's nameplate percentImpedance, loadLoss, noLoadLoss and percentMagnetizingCurrent, as the CIMTBL-Models templates.

What the decks hold.

connect_type instances phases voltages as written kVA GridLAB-D's impedance base
SINGLE_PHASE_CENTER_TAPPED 7,508 AS 2,394, BS 2,467, CS 2,647 primary = the coil (phase to neutral: 7216.88, 2400), secondary = a half (120) the instance phase's powerX_rating primary V² / phase kVA, half V² / phase kVA (:788, :1003 for NR)
WYE_WYE 1,432 ABCN 721, 2-phase 130, 1-phase 581 line to line on every phase count (12500/480 on a CN can) power_rating (or the phase sum), the whole unit secondary_voltage² / power_rating (:266)
DELTA_GWYE 2 ABCN, ABC line to line the whole unit as WYE_WYE
DELTA_DELTA 1 ABCN line to line the whole unit as WYE_WYE

WYE_WYE phase kVAs, by instance: 1,170 rate every wired phase equally (or rate none: GridLAB-D splits power_rating evenly, init():190); 145 rate every wired phase but unequally (22 2-phase, 123 3-phase: transformer_configuration:1226 of orig_R2-12.47-1, 37.5 + 25 + 25 kVA); 117 leave a wired phase at 0 or unset (8 2-phase, 109 3-phase: 15 / 0 / 0 kVA on ABCN). GridLAB-D reads only the total on a WYE_WYE (:266). No configuration is used by instances of different phase counts; 10 WYE_WYE configurations have no instance. 24 decks solve by NR, 4 by FBS.

Identity (S3b-1): xc_<configuration>, xb_<configuration> (a bank), xf_<transformer>, the GLM name in source case, as S2 and S3a. Children as the DSS import: xc_<c>_end_<n>, xc_<c>_wdg_<n>, xc_<c>_mesh_<ij>, xc_<c>_lug_<h1>; a bank's cans xc_<c>_<phase> (xc_transformer_configuration:1226_A); xf_<t>_tank (one tank, unnamed: it goes by its transformer's name) or xf_<t>_tank_<phase> (a bank, named <t>_<phase>: each can is a unit of its own on export), xf_<t>_<n> (ends), xf_<t>_<n>_<phase> (phase ends), xf_<t>_limits.

Templates (transformer_configuration.cimtbl)

Every configuration is written (S3b-1), used or not. A template is the configuration as its instances wire it, so where an instance says more (a center tap's primary system, which phases a bank's cans sit on), every instance of one configuration must say the same, else it raises. A configuration with no instance is built from its own phase ratings (none rated: three phases, as init():190); an unused center tap leaves its primary ratedU unset (no instance says its system), and none is in the decks.

Three forms (S3b-2). TransformerTankEnd is for three-phase templates only; a single-phase one is TransformerLugs, its instance TransformerPhaseEnds (the user's rule, 2026-11-19, S3b-13):

  • A three-phase tank by tank ends (a WYE_WYE on three phases rated equally, or not every one rated; DELTA_GWYE, DELTA_DELTA): a TransformerTankEnd per winding (connectionKind Y or D) and a TransformerWinding each, with ratings; the impedance is the configuration's %Z fields (S3b-5).
  • Lugged cans, one per wired phase: a WYE_WYE or SINGLE_PHASE on one phase (one can, xc_<c>) or two (a bank), or on three all rated with different kVAs (a bank, S3b-9). A bank is a TransformerBankConfiguration xb_<c> and one TransformerTankConfiguration per can xc_<c>_<label> (BankConfiguration = xb_<c>), as the CIMTBL-Models open-wye bank; its instance a tank per can, <transformer>_<phase>. A can has lugs H1, H2, X1, X2 and windings H1→H2, X1→X2; a lug's sequenceNumber is the conductor it lands on, numbered over the unit: end 1's phases then N, then end 2's (ABCN: H side A B C N = 1-4, X side 5-8; can A's H1, H2, X1, X2 = 1, 4, 5, 8; one can 1-4). Cans rated unequally are labelled and sized by their phases; otherwise they share power_rating equally, as GridLAB-D runs them, and are labelled by place (_1, _2), since one template serves instances on any phases (the walk collapses an unrated template's letters to a count). The instance's phase ends carry its own phases.
  • A center tap by lugs: H1, H2, X1, X3, X2 (sequence 1-5) with windings H1→H2, X1→X2 (s1→N), X2→X3 (N→s2), as the DSS import, with ratings; its %Z fields are the full winding's, which GridLAB-D splits into its star (below).
# orig_R1-12.47-1: a CN can, 12500/480 V as written (line to line), 75 kVA, z = 0.00133+0.00667j and shunt
# 443.91+424.448j on 480² / 75 kVA, i.e. 3 x on the can's own nameplate (S3b-4)
Table TransformerTankConfiguration: mRID, name, percentImpedance (percent), loadLoss (kW), noLoadLoss (kW), percentMagnetizingCurrent (percent)
    xc_transformer_configuration:3730, transformer_configuration:3730, 2.0404, 0.29925, 0.05632, 0.07853
Table TransformerTankEnd: mRID, TankConfiguration, endNumber, connectionKind
    xc_transformer_configuration:3730_end_1, xc_transformer_configuration:3730, 1, Y
    xc_transformer_configuration:3730_end_2, xc_transformer_configuration:3730, 2, Y
Table TransformerWinding: mRID, TankConfiguration, ratedU (V), baseU (V), ratedS (kVA), baseS (kVA), FromTransformerEnd
    xc_transformer_configuration:3730_wdg_1, ..., 12500.0, 7216.878, 75.0, 75.0, xc_transformer_configuration:3730_end_1
    xc_transformer_configuration:3730_wdg_2, ..., 480.0,   277.128,  75.0, 75.0, xc_transformer_configuration:3730_end_2

# IEEE13_cdpsm xcon_xfm1: 3-phase, GridLAB-D's base is the nameplate: 0.011+0.02j on 500 kVA
    xc_xcon_xfm1, xcon_xfm1, 2.2825, 5.5, , 

# orig_R2-12.47-1: 37.5 + 25 + 25 kVA on ABCN, a bank of three cans (S3b-9); one zt in ohms on every phase, so
# each can's %Z on its own kVA is z x 3 S_can / S_total
Object TransformerBankConfiguration: mRID=xb_transformer_configuration:1226, name=transformer_configuration:1226
Table TransformerTankConfiguration: mRID, name, percentImpedance (percent), loadLoss (kW), noLoadLoss (kW), percentMagnetizingCurrent (percent), BankConfiguration
    xc_transformer_configuration:1226_A, transformer_configuration:1226_A, 0.74863, 0.054964, 0.062059, 0.18261, xb_transformer_configuration:1226
    xc_transformer_configuration:1226_B, transformer_configuration:1226_B, 0.49909, 0.024429, 0.062059, 0.27392, xb_transformer_configuration:1226
    xc_transformer_configuration:1226_C, transformer_configuration:1226_C, 0.49909, 0.024429, 0.062059, 0.27392, xb_transformer_configuration:1226
Table TransformerLug: mRID, TankConfiguration, designation, sequenceNumber
    xc_transformer_configuration:1226_A_lug_h1, xc_transformer_configuration:1226_A, H1, 1
    xc_transformer_configuration:1226_A_lug_h2, xc_transformer_configuration:1226_A, H2, 4
    xc_transformer_configuration:1226_A_lug_x1, xc_transformer_configuration:1226_A, X1, 5
    xc_transformer_configuration:1226_A_lug_x2, xc_transformer_configuration:1226_A, X2, 8
    ...                                                                              # B: 2, 4, 6, 8; C: 3, 4, 7, 8
Table TransformerWinding: mRID, TankConfiguration, ratedU (V), baseU (V), ratedS (kVA), baseS (kVA), FromTransformerLug, ToTransformerLug
    xc_transformer_configuration:1226_A_wdg_1, ..._A, 12470.0, 7199.558, 37.5, 37.5, ..._A_lug_h1, ..._A_lug_h2
    xc_transformer_configuration:1226_A_wdg_2, ..._A, 480.0,   277.128,  37.5, 37.5, ..._A_lug_x1, ..._A_lug_x2
    ...                                                                              # B, C: 25 kVA

# IEEE13_cdpsm xcon_ct5B: its impedance/impedance1/impedance2 are GridLAB-D's split of R = 1.2 %, X = 1.7 %
Table TransformerTankConfiguration: mRID, name, percentImpedance (percent), loadLoss (kW), noLoadLoss (kW), percentMagnetizingCurrent (percent)
    xc_xcon_ct5B, xcon_ct5B, 2.08087, 0.06, 0.01, 0.5
Table TransformerLug: ...                                                            # H1 H2 X1 X3 X2 = 1-5
Table TransformerWinding: mRID, TankConfiguration, ratedU (V), baseU (V), ratedS (kVA), baseS (kVA), FromTransformerLug, ToTransformerLug
    xc_xcon_ct5B_wdg_1, xc_xcon_ct5B, 4156.92, 2400.0, 5.0, 5.0, xc_xcon_ct5B_lug_h1, xc_xcon_ct5B_lug_h2
    xc_xcon_ct5B_wdg_2, xc_xcon_ct5B, 240.0,   120.0,  2.5, 5.0, xc_xcon_ct5B_lug_x1, xc_xcon_ct5B_lug_x2
    xc_xcon_ct5B_wdg_3, xc_xcon_ct5B, 240.0,   120.0,  2.5, 5.0, xc_xcon_ct5B_lug_x2, xc_xcon_ct5B_lug_x3

Expanded by the split (below), the center tap equals the DSS import's xc_ct5 in SI: r 0.6 / 1.2 / 1.2 % and x 2.04 / 2.04 / 1.36 % on 5 kVA.

GLM slot kind target
name copied TransformerTankConfiguration.name (a bank: TransformerBankConfiguration.name, each can <name>_<phase>); mRID = xc_ (xb_) + name
connect_type structural the form and connection kinds: WYE_WYE Y/Y (on one or two phases lugged cans), DELTA_GWYE D/Y, DELTA_DELTA D/D (TransformerTankEnd.connectionKind; grounding is the instance's); SINGLE_PHASE_CENTER_TAPPED lugs; SINGLE_PHASE as WYE_WYE (S6-2); unset raises
primary_voltage, secondary_voltage structural winding ratedU and baseU, in the written unit (V in every deck), S3b-3
power_rating, powerA_rating/_B_/_C_ structural winding ratedS, baseS (S3b-3): the whole unit's kVA (power_rating, else the phase sum, as init()), a can's its phase's when the wired phases are rated unequally, else an equal share; a center tap's is its instance phase's rating. Phase kVAs a one-tank template does not use are listed on the row
impedance, resistance, reactance derived percentImpedance = |R + jX| × k × 100 and loadLoss = R × k × S (S3b-4, S3b-5); a center tap's are the full winding's
impedance1, impedance2 (and their resistance/reactance forms) derived a center tap's star given whole; it must be GridLAB-D's own split of one R + jX (impedance = 0.5R + j0.8X, both halves R + j0.4X), which gives the %Z fields; any other split raises (none in the decks), and on any other connection they raise (GridLAB-D ignores them with a warning)
shunt_impedance, shunt_resistance, shunt_reactance derived noLoadLoss = S / (Rsh × k) and percentMagnetizingCurrent = 100 / (Xsh × k) (S3b-6); unset: GridLAB-D's 999999999 pu (lossless) is not filled; on a delta connection raises (ignored with a warning)
no_load_loss, full_load_loss, reactance_resistance_ratio structural raise when set: they replace the impedances on a center tap (:283), and no deck sets them
install_type, coolant_type, cooling_type, core_coil_weight, tank_fittings_weight, oil_volume, rated_winding_time_constant, rated_winding_hot_spot_rise, rated_top_oil_rise, installed_insulation_life untranscribed thermal aging model and siting; no network-profile home (as the DSS thermal slots)
magnetization_location, inrush_saturation_enabled, L_A, phi_K, phi_M, I_M, T_D untranscribed inrush model
object header untranscribed as S2

The tank's own base (S3b-4). GridLAB-D's per unit is on secondary_voltage² / power_rating as written (line to line, the whole unit, transformer.cpp:266); CIM's %Z fields are on the tank's own nameplate, per coil. So every value is GridLAB-D's ohms re-expressed on the tank: k = 3 × S_coil / S_total, with S_coil the kVA of one phase coil of the tank (S_total / n for one tank of n wye conductors, the can's kVA in a bank). k is 1 on 3-phase and delta units, 3 on a 1-phase WYE_WYE can, 1.5 on a 2-phase one, and 3 S_can / S_total on a bank's can. A center tap's base is already its coil (:784: primary V² / phase kVA), so k = 1.

Center tap: GridLAB-D's star. With S the instance phase's rating, GridLAB-D puts z0 = 0.5 R + j 0.8 X of impedance on the primary and z1 = z2 = R + j 0.4 X on the halves (transformer.cpp:788, :1003 for NR): the Hopkinson split the CIMTBL-Models pole-mount templates infer from percentImpedance and loadLoss (mesh 1.5R + j1.2X to each half, 2R + j0.8X between them). So the %Z fields carry R + jX and the split is the reader's, as there. impedance1/impedance2 give the star whole; IEEE13_cdpsm's xcon_ct5B (0.006+0.0136j, 0.012+0.0068j twice) is the split of R = 0.012, X = 0.017.

Instances (transformer.cimtbl)

# IEEE13_cdpsm xf_xfm1: ends carry the node, phases and grounding; the values live in the template
Table PowerTransformer: mRID, name, EquipmentContainer=fdr_IEEE13_cdpsm
    xf_xf_xfm1, xf_xfm1
Table TransformerTank: mRID, PowerTransformer, TankConfiguration, EquipmentContainer=fdr_IEEE13_cdpsm
    xf_xf_xfm1_tank, xf_xf_xfm1, xc_xcon_xfm1
Table PowerTransformerEnd: mRID, PowerTransformer, node, phases, endNumber, connectionKind, grounded, BaseVoltage
    xf_xf_xfm1_1, xf_xf_xfm1, xf1, ABCN, 1, Yn, true, bv_4p16kv
    xf_xf_xfm1_2, xf_xf_xfm1, 634, ABCN, 2, Yn, true, bv_480v

# orig_R2-12.47-1 R2-12-47-1_xfmr_115: the bank, a tank per can; the phase ends say which conductor is which
Table TransformerTank: mRID, PowerTransformer, TankConfiguration, EquipmentContainer=fdr_orig_R2-12.47-1
    xf_R2-12-47-1_xfmr_115_tank_A, xf_R2-12-47-1_xfmr_115, xc_transformer_configuration:1226_A
    xf_R2-12-47-1_xfmr_115_tank_B, xf_R2-12-47-1_xfmr_115, xc_transformer_configuration:1226_B
    xf_R2-12-47-1_xfmr_115_tank_C, xf_R2-12-47-1_xfmr_115, xc_transformer_configuration:1226_C
Table PowerTransformerEnd: ...
    xf_R2-12-47-1_xfmr_115_1, ..., ABCN, 1, Yn, true, ...
Table TransformerPhaseEnd: mRID, endNumber, sequenceNumber, phase, Terminal
    xf_R2-12-47-1_xfmr_115_1_A, 1, 1, A, xf_R2-12-47-1_xfmr_115_T1
    ...                                                       # B C N = 2-4; end 2 A B C N = 5-8

# IEEE13_cdpsm xf_tpoletop: values in the template; the DSS import's phase ends B, N, s1, s2, N = 1-5
Table PowerTransformerEnd: mRID, PowerTransformer, node, phases, endNumber, connectionKind, grounded, BaseVoltage
    xf_xf_tpoletop_1, xf_xf_tpoletop, 670,   BN,    1, Y, true, bv_4p16kv
    xf_xf_tpoletop_2, xf_xf_tpoletop, house, s1s2N, 2, I, true, bv_240v
GLM slot kind target
name copied PowerTransformer.name; mRID = xf_ + name
from, to structural end 1 and end 2 node: the root bus (GLM-4); each end's BaseVoltage is the walk's
phases structural the ends' phases (S3b-7), and a bank's phase ends
configuration structural each TransformerTank.TankConfiguration (xc_<configuration>, or a bank's xc_<configuration>_<phase>); unset or not a transformer_configuration raises
status structural unset or CLOSED; OPEN raises (the walk)
continuous_rating_X, emergency_rating_X structural the transformer's own OperationalLimitSet, as S3a-5 (S3b-8)
climate, ambient_temperature, top_oil_hot_spot_temperature, winding_hot_spot_temperature, percent_loss_of_life, aging_constant, use_thermal_model, transformer_replacement_count, aging_granularity untranscribed thermal aging model and its state
phase_X_primary_flux_value, phase_X_secondary_flux_value, inrush_* untranscribed inrush state and settings
the link outputs, dispatch, nominal_voltage, mean_repair_time and header slots untranscribed as S3a

Fail fast (S3b)

condition why
connect_type unset; voltages or kVA unset or 0; phase ratings that miss power_rating by more than 1 % transformer_configuration.cpp:193, :211, :227, :234 throw
resistance or reactance unset or not positive; impedance set with a resistance/reactance that differs :337 throws (no lossless unit); the slots are one value
impedance1/impedance2 or a shunt on a connection that ignores it; only one of impedance1/impedance2; no_load_loss/full_load_loss set GridLAB-D warns and ignores, or fills in its own; none in the decks
a center tap on phases other than one letter + S, or whose phase's powerX_rating is unset or 0 transformer.cpp:772 throws
a WYE_WYE without N or with S; a delta connection not on ABC/ABCN; an end the walk does not put on a 3-phase system (center-tap secondary: split-phase) transformer.cpp:315 throws on S; the rest is in no deck
instances of one configuration that wire it differently (bus systems, phases, so a different template) one template per configuration
per-phase ratings that differ as S3a

Decisions for S3b

# question decision (approved)
S3b-1 Files and identity The user's: every configuration is written, used or not. The two artifacts above; xc_, xb_ and xf_ in source case; children named as the DSS import
S3b-2 Template forms A three-phase tank by tank ends (a 3-phase WYE_WYE equal or not fully rated, the deltas); lugged cans, one (a one-phase wye) or a bank under a TransformerBankConfiguration (a two-phase wye, unequal cans, S3b-9); a center tap by lugs H1 H2 X1 X3 X2 (the DSS import's). Amended by S3b-13 (one- and two-phase wyes were tank ends)
S3b-3 Voltages and kVA (amends GLM-6) GLM-6's "1-phase WYE_WYE voltages are phase to neutral" is wrong: the decks and the engine take them line to line on every phase count (the walk's S0 finding). So ratedU is the written voltage and baseU the coil (÷ √3 on a wye, as written on a delta); ratedS the tank's kVA, baseS its share per phase conductor. A center tap's primary is the coil: baseU as written, ratedU × √3 on a 3-phase system (the walk); a half's baseU is secondary_voltage, its ratedU × 2, its ratedS S / 2, every baseS S. Derived values are never rounded. Amended by S6-1: true of the Java exports; a wye whose written voltage is its from bus's nominal_voltage is rated by the coil
S3b-4 Impedance base The user's: keep GridLAB-D's ohms. Its per unit is on its own base (written line-to-line voltage, whole-unit kVA); the %Z fields are on each tank's nameplate, so every value is moved by k = 3 S_coil / S_total (above): 1 on 3-phase, delta and center-tap units, 3 on the 581 1-phase and 1.5 on the 130 2-phase WYE_WYE units, per can in a bank. Copying the written per unit would give a 1-phase can a third of the impedance GridLAB-D solves with
S3b-5 Where the impedance goes The user's: GLM stores %Z (one R + jX per unit and a parallel shunt), not a mesh, so it goes on the TransformerTankConfiguration: percentImpedance, loadLoss, noLoadLoss, percentMagnetizingCurrent. R comes back exactly as loadLoss / S and X as √(Z² − R²) (GridLAB-D requires both positive). No winding r, no mesh, nothing on the instance ends; a center tap's split is GridLAB-D's (the Hopkinson rule the CIMTBL-Models templates use)
S3b-6 Shunt shunt_resistance/shunt_reactance are GridLAB-D's parallel branch (zc = Rsh·jXsh / (Rsh + jXsh)): the real part is noLoadLoss = S / (Rsh k), the reactive part percentMagnetizingCurrent = 100 / (Xsh k), as the DSS import's %noloadloss/%imag. The written value is kept although GridLAB-D's NR ignores the shunt on WYE_WYE (transformer.cpp:362 builds only 1 / zt); FBS and every center tap use it
S3b-7 Instance ends and phases End 1 = from, end 2 = to. WYE_WYE: the written letters + N on both, Yn grounded. DELTA_GWYE: ABC D ungrounded, then ABCN Yn grounded (the G), whether N is written or not. DELTA_DELTA: ABC D on both, N dropped. Center tap: XN Y, then s1s2N I, with the DSS import's phase ends. A bank has a phase end per conductor of each terminal, numbered as its lugs. A one-tank instance has none: every GLM coil runs from its phase to N (or is 3-phase), which the terminal phases already say
S3b-8 Ratings As S3a-5: the 3 Java-export transformers' continuous_rating_X/emergency_rating_X go, as written, on the transformer's own OperationalLimitSet. They are primary-side amps (27.61 A = 1.1 × the 25.1 A of 5 MVA at 115 kV). GridLAB-D replaces them with the configuration's kVA (transformer.cpp:234)
S3b-9 Unequal cans The user's: each can a tank, the bank a TransformerBankConfiguration. A WYE_WYE instance whose wired phases are all rated, with different kVAs, is a bank (145 instances): a can per wired phase of its phase's kVA, lugged on the bank's conductors as the CIMTBL-Models open-wye bank. GridLAB-D puts one zt in ohms on every phase, so each can's %Z fields are those ohms on its own kVA (S3b-4). Best guess for the 117 that leave a wired phase unrated (15 / 0 / 0 kVA on ABCN): no can size exists for that phase, and GridLAB-D still runs it through the same zt, so they stay one tank of power_rating, the phase kVAs listed on the row. Equally rated 2-phase units (100) stay one tank too. Amended by S3b-13: on one or two phases they are lugged cans of equal shares of power_rating, the phase kVAs still listed
S3b-10 Vector group Not written, as the DSS import: the connection kinds hold the form (the Java export's // vector group Dyn1y1 is a comment the reader does not keep)
S3b-11 Shared code The center-tap lug layout and star_to_mesh are what DSS uses too. They are copied into this spoke (no cross-spoke import) and listed in plan section 7 as core candidates, as limit_types was
S3b-12 Field tables Generated from the mappers' FIELDS with fields_table (below), as S3a-11
S3b-13 TankEnds three-phase only (the user's, 2026-11-19, via clallam_cim request 10) "TransformerTankEnd is only for three-phase templates, single-phase should use TransformerPhaseEnd / TransformerLug." A WYE_WYE/SINGLE_PHASE on one phase is one lugged can, on two a bank of two (S3b-2), as the DSS import writes a 1-phase XfmrCode. Electrically unchanged: each can's %Z fields are GridLAB-D's ohms on its own kVA (k = 3 S_can / S, or S_can / S coil-rated, S3b-4), as the tank ends' per-phase base was, and the DSS export is one 1-phase Transformer per can in place of a phases=2 one. JOHNSON CREEK solves the same (per-phase pu range and total kW unchanged over its 4157 nodes), its TankEnds 78 → 36

Core owes (plan section 7): the transformer getter (getters/transformer.py) reads impedance only from winding r and the mesh; percentImpedance/loadLoss are open in GETTERS_PLAN.md ("test summaries ... not checked against the mesh"), a gap the DSS exporter hit too. It needs to read the %Z fields (with the center tap's Hopkinson split) and a bank of lugged template tanks by their phase ends (it raises on a bank today) before any exporter can read these templates. S3b's tests do not go through the getter.

Tests. An atom tests/atoms/transformer/transformer.glm on the line atom (it already has a center tap): xcon_xfm1, xcon_sub3, IEEE123's DELTA_DELTA, a taxonomy CN can, an unequal 3-can bank and an unequal 2-phase one, a unit with an unrated wired phase, xcon_ct5B (impedance1/2 and shunt), a taxonomy center tap without them, an unused configuration, and a rated instance; one golden per part, fail-fast cases, IEEE13_cdpsm goldens. The engine check (GLM-16): on every deck, each bound transformer's tank fields, turned back into ohms on the tank's coils (and, on a center tap, through the split), must equal GridLAB-D's zt and zc (or z0, z1, z2 and zc) computed from the configuration by the C++ formulas cited above; and each bank's cans must sum to power_rating.

Expected differences from the DSS import of IEEE13 (GLM-16). The DSS import writes xfm1 and sub3 inline (by ends, r per end, x on a mesh) and ct5 as a template with winding r and a mesh; GLM writes all three by template with %Z fields, so the comparison is on values in SI, matched by nodes. xfm1: equal (2.2825 %Z, 5.5 kW load loss against 0.55 % on each end and 2 % x). ct5: equal through the split. sub3: the Java export wrote a 2-winding DELTA_GWYE of the DSS 3-winding unit, so the 13.2 kV tertiary (650z, 1000 kVA) and the 0.4 Ω neutral reactance on winding 2 are missing; the 115/4.16 kV pair agrees. mRIDs carry the Java prefixes (xf_xf_xfm1 vs xf_xfm1). The transformers carry limit sets the DSS import does not write.

Built (2026-11-09)

  • importer/cimtbl/transformer_configuration.py (map_transformer_configuration, wirings: the three forms, the %Z fields on each tank's nameplate, the center-tap split check) and transformer.py (map_transformers: tanks, ends, phase ends, limit sets), wired into MAPPING_ORDER (rows 5 and 10) and CLASSIFIED. link.provenance takes the spec anchor.
  • The S1 feeder atom's two configurations gained an impedance (GridLAB-D throws without one) and the center tap its powerA_rating; the bus and source goldens are unchanged.
  • Atom tests/atoms/transformer/transformer.glm (on the S3a line atom: xcon_xfm1 with ratings, DELTA_GWYE written ABC, DELTA_DELTA, a taxonomy CN can with a shunt, a 37.5 + 25 + 25 kVA bank, a 15 + 25 kVA 2-phase bank, a unit with unrated wired phases, xcon_ct5B, a taxonomy center tap with a shunt, an unused configuration) with one golden per part; goldens tests/goldens/IEEE13_cdpsm/transformer_configuration, transformer; tests/test_cimtbl_transformer.py (classification, the atom bound and read back, 10 fail-fast cases, and on every deck: every configuration written, and each tank's %Z fields turned back into ohms and siemens equal GridLAB-D's zt/zc, or z0/z1/zc on a center tap, from the configuration by the C++ formulas).
  • Every deck that binds S3a binds S3b: 27 of 29, the same two deck defects; 8,927 transformers in 9,195 tanks, 145 of them banks (95 bank configurations).

Field tables (generated: fields_table(cls, records, fields=...), samples from tests/decks and the atom)

The object header (parent, groupid, latitude, longitude, in_svc, out_svc, rank, flags) and, on the transformer, the link's solver outputs and state and inrush settings (as S3a) are untranscribed and left out.

transformer_configuration

TransformerConfiguration field type samples kind target
name Union[str, TransformerConfigurationName] xcon_ct5B, xcon_sub3, xcon_xfm1 copied TransformerTankConfiguration.name; mRID = xc_ + name; a bank xb_ + name, its cans xc_ + name + ( unrated)
connect_type Optional[str] SINGLE_PHASE_CENTER_TAPPED, DELTA_GWYE, WYE_WYE structural the form and connectionKinds: WYE_WYE and SINGLE_PHASE Y/Y (on one or two phases lugs), DELTA_GWYE D/Y, DELTA_DELTA D/D, SINGLE_PHASE_CENTER_TAPPED lugs; unset raises
install_type Optional[str] POLETOP, PADMOUNT untranscribed thermal aging model and siting; no network-profile home
coolant_type Optional[str] untranscribed thermal aging model and siting; no network-profile home
cooling_type Optional[str] untranscribed thermal aging model and siting; no network-profile home
primary_voltage Optional[float] 2400.0, 115000.0, 4160.0 structural winding 1 ratedU (line to line) and baseU (the coil), S3b-3; a coil-rated wye's is baseU, ratedU on its bus's system (S6)
secondary_voltage Optional[float] 120.0, 4160.0, 480.0 structural winding 2 ratedU and baseU; a center tap's half (ratedU x 2)
power_rating Optional[float] 5.0, 5000.0, 500.0 structural ratedS: the whole unit's kVA, else the phase sum (init())
powerA_rating Optional[float] 0.0, 75.0, 1000.0 structural a can's kVA when the wired phases are rated unequally; a center tap's S on its phase; else unused, listed when it is not S / n
powerB_rating Optional[float] 5.0, 75.0, 1000.0 structural a can's kVA when the wired phases are rated unequally; a center tap's S on its phase; else unused, listed when it is not S / n
powerC_rating Optional[float] 0.0, 75.0, 1000.0 structural a can's kVA when the wired phases are rated unequally; a center tap's S on its phase; else unused, listed when it is not S / n
resistance Optional[float] 1e-05, 0.011, 0.0127 derived percentImpedance =
reactance Optional[float] 0.0001, 0.02, 8e-05 derived percentImpedance =
impedance Union[dict, Complex, NoneType] Complex({'real': 0.006, 'imag': 0.0136}) derived percentImpedance =
resistance1 Optional[float] derived a center tap's star given whole: must be GridLAB-D's split of one R + jX (impedance = 0.5R + j0.8X, both halves R + j0.4X); any other split, or on another connection, raises
reactance1 Optional[float] derived a center tap's star given whole: must be GridLAB-D's split of one R + jX (impedance = 0.5R + j0.8X, both halves R + j0.4X); any other split, or on another connection, raises
impedance1 Union[dict, Complex, NoneType] Complex({'real': 0.012, 'imag': 0.0068}) derived a center tap's star given whole: must be GridLAB-D's split of one R + jX (impedance = 0.5R + j0.8X, both halves R + j0.4X); any other split, or on another connection, raises
resistance2 Optional[float] derived a center tap's star given whole: must be GridLAB-D's split of one R + jX (impedance = 0.5R + j0.8X, both halves R + j0.4X); any other split, or on another connection, raises
reactance2 Optional[float] derived a center tap's star given whole: must be GridLAB-D's split of one R + jX (impedance = 0.5R + j0.8X, both halves R + j0.4X); any other split, or on another connection, raises
impedance2 Union[dict, Complex, NoneType] Complex({'real': 0.012, 'imag': 0.0068}) derived a center tap's star given whole: must be GridLAB-D's split of one R + jX (impedance = 0.5R + j0.8X, both halves R + j0.4X); any other split, or on another connection, raises
shunt_resistance Optional[float] 500.0, 166.666667 derived noLoadLoss = S / (Rsh x k), percentMagnetizingCurrent = 100 / (Xsh x k) (S3b-6); unset: GridLAB-D's 999999999 pu (lossless) is not filled; on a delta connection raises
shunt_reactance Optional[float] 200.0, 90.909092 derived noLoadLoss = S / (Rsh x k), percentMagnetizingCurrent = 100 / (Xsh x k) (S3b-6); unset: GridLAB-D's 999999999 pu (lossless) is not filled; on a delta connection raises
shunt_impedance Union[dict, Complex, NoneType] Complex({'real': 6545.46, 'imag': 665..., Complex({'real': 1226.16, 'imag': 135..., Complex({'real': 391.76, 'imag': 390.... derived noLoadLoss = S / (Rsh x k), percentMagnetizingCurrent = 100 / (Xsh x k) (S3b-6); unset: GridLAB-D's 999999999 pu (lossless) is not filled; on a delta connection raises
core_coil_weight Optional[float] untranscribed thermal aging model and siting; no network-profile home
tank_fittings_weight Optional[float] untranscribed thermal aging model and siting; no network-profile home
oil_volume Optional[float] untranscribed thermal aging model and siting; no network-profile home
rated_winding_time_constant Optional[float] untranscribed thermal aging model and siting; no network-profile home
rated_winding_hot_spot_rise Optional[float] untranscribed thermal aging model and siting; no network-profile home
rated_top_oil_rise Optional[float] untranscribed thermal aging model and siting; no network-profile home
no_load_loss Optional[float] structural raises when set: it replaces the impedances on a center tap (transformer_configuration.cpp:283), and no deck sets it
full_load_loss Optional[float] structural raises when set: it replaces the impedances on a center tap (transformer_configuration.cpp:283), and no deck sets it
reactance_resistance_ratio Optional[float] structural raises when set: used only with no_load_loss and full_load_loss
installed_insulation_life Optional[float] untranscribed thermal aging model and siting; no network-profile home
magnetization_location Optional[str] untranscribed inrush model
inrush_saturation_enabled Union[bool, Bool, NoneType] untranscribed inrush model
L_A Optional[float] untranscribed inrush model
phi_K Optional[float] untranscribed inrush model
phi_M Optional[float] untranscribed inrush model
I_M Optional[float] untranscribed inrush model
T_D Optional[float] untranscribed inrush model

transformer

Transformer field type samples kind target
name Union[str, TransformerName] xf_sub3, xf_tpoletop, xf_xfm1 copied PowerTransformer.name; mRID = xf_ + name
phases Optional[str] ABCN, BS, ABC structural the ends' phases and kinds (S3b-7), and a bank's or center tap's phase ends
nominal_voltage Optional[float] untranscribed the walk gives the BaseVoltage (GLM-1)
status Optional[str] structural unset or CLOSED; OPEN raises (the walk)
from_node Optional[str] sourcebus, 670, xf1 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] 650, house, 634 structural node2: the root bus of the object it names (GLM-4)
pdispatch Optional[float] untranscribed dispatch control; no network-profile home
pdispatch_offset Optional[float] untranscribed dispatch control; no network-profile home
set_pdispatch Union[bool, Bool, NoneType] untranscribed dispatch control; no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
continuous_rating_A Optional[float] 27.61, 76.33, 22.9 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_B Optional[float] 27.61, 76.33, 22.9 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_C Optional[float] 27.61, 76.33, 22.9 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
emergency_rating_A Optional[float] 37.65, 104.09, 31.23 structural the emergency CurrentLimit of that set
emergency_rating_B Optional[float] 37.65, 104.09, 31.23 structural the emergency CurrentLimit of that set
emergency_rating_C Optional[float] 37.65, 104.09, 31.23 structural the emergency CurrentLimit of that set
configuration Optional[str] xcon_sub3, xcon_ct5B, xcon_xfm1 structural TransformerTank.TankConfiguration = xc_ (a bank: one tank per can, xc__)
climate Optional[str] untranscribed thermal aging model and its state
ambient_temperature Optional[float] untranscribed thermal aging model and its state
top_oil_hot_spot_temperature Optional[float] untranscribed thermal aging model and its state
winding_hot_spot_temperature Optional[float] untranscribed thermal aging model and its state
percent_loss_of_life Optional[float] untranscribed thermal aging model and its state
aging_constant Optional[float] untranscribed thermal aging model and its state
use_thermal_model Union[bool, Bool, NoneType] untranscribed thermal aging model and its state
transformer_replacement_count Optional[float] untranscribed thermal aging model and its state
aging_granularity Optional[float] untranscribed thermal aging model and its state
phase_A_primary_flux_value Optional[float] untranscribed inrush state
phase_B_primary_flux_value Optional[float] untranscribed inrush state
phase_C_primary_flux_value Optional[float] untranscribed inrush state
phase_A_secondary_flux_value Optional[float] untranscribed inrush state
phase_B_secondary_flux_value Optional[float] untranscribed inrush state
phase_C_secondary_flux_value Optional[float] untranscribed inrush state

S3c: regulators (by the user's direction 2026-11-09; built 2026-11-09)

S3c maps regulator with its regulator_configuration (GLM-7), plan section 2 rows 6 and 11. The user's direction: a regulator is a VoltageRegulator with two AutoTransformerEnds, never a TransformerTankEnd; an LTC on a step-down transformer would be a PowerTransformerEnd; the lack of impedance is why AutoTransformerEnd exists. GLM has no LTC: a GridLAB-D regulator has no voltage ratio (it is 1:1 by construction), and a transformer has no tap changer. So every GLM regulator is a VoltageRegulator, and the core voltage_regulator shape applies without its mesh. GridLAB-D citations are to powerflow/regulator.cpp and regulator_configuration.cpp.

# artifact native class (records) CIM mRID
6 none regulator_configuration (36) none on its own: CIM has no regulator template (an AutoTransformer has none), so the mapper copies a configuration's values onto every unit that names it
11 regulator.cimtbl regulator (36) VoltageRegulator + two AutoTransformerEnds + TapChangerControl + RatioTapChanger per unit xf_<name>[_<phase>], rc_<name>[_<phase>]

What the decks hold (the 28 readable decks): 36 regulators, one configuration each, all WYE_WYE. control_level is never set (GridLAB-D's default INDIVIDUAL); Control is OUTPUT_VOLTAGE 28, MANUAL 7 (the Java exports, whose LINE_DROP_COMP is commented out), REMOTE_NODE 1 (IEEE13_houses, which stops at the walk). Type is set on the 6 Java-export configurations (B); CT_phase, PT_phase, reverse_flow_control and the regulator's tap_X are never set. Phases: ABCN 30 and the Java exports' CAB, BCA, CBA, ABC, CA, A. raise_taps = lower_taps = 16 and regulation 0.1 everywhere. No regulator sets regulator_resistance.

# IEEE13_cdpsm xf_Reg (phases CAB, MANUAL, Type B, tap_pos 10 / 8 / 11): three units, as the DSS import's reg1-3
Table VoltageRegulator: mRID, name, construction, EquipmentContainer=fdr_IEEE13_cdpsm
    xf_xf_Reg_A, xf_Reg_A, typeB                       # and _B, _C
Table AutoTransformerEnd: mRID, AutoTransformer, node, phase, endNumber, grounded=true, baseU (V), BaseVoltage
    xf_xf_Reg_A_1, xf_xf_Reg_A, brkr, AN, 1, 2401.78, bv_4p16kv
    xf_xf_Reg_A_2, xf_xf_Reg_A, rg60, AN, 2, 2401.78, bv_4p16kv
Table TapChangerControl: mRID, name, mode=voltage, discrete=true, enabled, monitoredPhase, ptRatio, targetValue, targetDeadband, lineDropCompensation, lineDropR (ohm), lineDropX (ohm), Terminal
    rc_xf_Reg_A, xf_Reg_A, false, A, 20.0, , , false, 0.017142857142857144, 0.05142857142857143, xf_xf_Reg_A_T2
Table RatioTapChanger: mRID, name, TransformerEnd, TapChangerControl, lowStep, highStep, neutralStep=0, step, stepVoltageIncrement (percent), neutralU (V), ltcFlag=true, controlEnabled, ptRatio, ctRatio, initialDelay (s), subsequentDelay (s)
    rc_xf_Reg_A_tap, xf_Reg_A, xf_xf_Reg_A_2, rc_xf_Reg_A, -16, 16, 10, 0.625, 2401.78, false, 20.0, 3500.0, 15.0, 15.0
GLM slot kind target
regulator name derived VoltageRegulator.name = name (BANK) or name_ (INDIVIDUAL); mRID xf_ + that; the control rc_ + that, its tap changer + _tap
from, to structural end 1 and end 2 node: the root bus (GLM-4); each end's BaseVoltage is the walk's
phases structural the units and each end's phase: the letter + N (a gang unit ABCN), N or not written (every unit is wye to neutral)
configuration structural its values on every unit (no template)
tap_A/_B/_C, tap_pos_A/_B/_C derived RatioTapChanger.step of the phase's unit: the regulator's tap_X, else the configuration's tap_pos_X, else 0 (regulator.cpp:146, :262)
raise_taps, lower_taps copied, derived highStep, lowStep = -lower_taps; neutralStep 0
regulation derived stepVoltageIncrement = regulation / raise_taps (GridLAB-D's tapChangePer, :244), in percent
Type mapped VoltageRegulator.construction: A typeA, B typeB (default B)
Control structural MANUAL (default): TapChangerControl.enabled = RatioTapChanger.controlEnabled = false; OUTPUT_VOLTAGE, LINE_DROP_COMP: true; lineDropCompensation on LINE_DROP_COMP only; REMOTE_NODE on the regulator's own output as OUTPUT_VOLTAGE (S6-6)
band_center, band_width derived targetValue, targetDeadband (full band, as CIM's): primary volts as written, × power_transducer_ratio on LINE_DROP_COMP, whose band is on the PT secondary (:1316)
power_transducer_ratio, current_transducer_ratio copied TapChangerControl.ptRatio, RatioTapChanger.ptRatio, RatioTapChanger.ctRatio, RatioTapChanger.ctRating (A, S3c-4)
compensator_r_setting_X, compensator_x_setting_X derived lineDropR, lineDropX (ohm) of the phase's unit = setting × PT ratio / CT ratio (line_drop_ohms; S3c-4)
dwell_time, time_delay derived initialDelay = subsequentDelay = dwell_time + time_delay (S3c-5)
control_level structural INDIVIDUAL: a unit per wired phase; BANK: one gang unit on ABC (GLM-7), or one unit on its one PT_phase (S6-7)
PT_phase, CT_phase structural BANK: monitoredPhase (the two must agree); INDIVIDUAL: GridLAB-D ignores them, listed on the row (S6-7)
regulator_resistance copied the unit's TransformerMeshImpedance.r (Ω), GridLAB-D's series resistance (default powerflow::default_resistance, 1e-4 Ω; S3c-2)
the link's ratings structural each unit's own OperationalLimitSet, its phase's continuous_rating_X/emergency_rating_X (a gang unit: as S3a-5); the continuous rating also gives ratedS (S3c-2)
msg_mode, remote_voltage_X, tap_X_change_count, the link outputs and header slots untranscribed co-simulation messaging, solver output or state, as S3a

Fail fast (S3c)

condition why
connect_type other than WYE_WYE regulator_configuration.cpp:232: NR takes only WYE_WYE; every deck is WYE_WYE
raise_taps or lower_taps unset or not positive; regulation unset or 0 on an automatic Control :198, :212 throw
Control REMOTE_NODE sensing a bus other than the regulator's own output S3c-6, S6-6
reverse_flow_control other than LOCK_NONE; a BANK on neither ABC nor its one PT_phase, whose PT_phase and CT_phase are not one equal phase, or whose taps differ in no deck; a gang holds one tap
a tap outside -lower_taps..+raise_taps GridLAB-D would clamp it on the first tap change, not at init
compensator settings without both transducer ratios the primary ohms need both; in no deck
phases with S or nothing in ABC; status OPEN as S3b
a unit with no continuous_rating_X (its phase's; a gang unit's any) ratedS is the rating × baseU (S3c-2); the PNNL taxonomy decks stop here

Decisions for S3c

# question decision
S3c-1 Form (GLM-7) The user's: a VoltageRegulator with two AutoTransformerEnds, no tank end; an LTC on a step-down transformer would be a PowerTransformerEnd, and GLM has none. One unit per wired phase on INDIVIDUAL (each its own RatioTapChanger on end 2 and TapChangerControl on its T2, as the DSS import's IEEE 13), one gang unit on BANK. mRID xf_ as the core shape and the DSS import
S3c-2 Impedance and kVA The user's, 2026-11-22 (replaces "ideal ends"): ratedS, baseU and phase are required on an AutoTransformerEnd, and each unit has a TransformerMeshImpedance. GridLAB-D's regulator has no kVA, so both ends' ratedS = the unit's continuous rating × baseU (× √3 on a gang unit, whose baseU is line to line); an unset rating raises (GridLAB-D's 1000 A default is not the regulator's, as S2-7), and glm-repair rates the deck. The mesh r is regulator_resistance (GridLAB-D's series resistance, default 1e-4 Ω) and its x a 0.01 % stand-in on ratedS (an engine may need one: OpenDSS solves XHL=0 wrong, 0.26 pu on a probe; 0.01 is the IEEE 13 deck's regulators' XHL)
S3c-3 Coil voltage baseU = neutralU = the from bus's nominal_voltage as written (phase to neutral, 2401.78 V): the coil the band works against (regulator.cpp:1380 compares the to-node's phase voltage). A gang unit's is that × √3 (line to line, as the core shape's 3-phase vr3)
S3c-4 Line drop GridLAB-D's compensator drop is (I / current_transducer_ratio) × (R + jX) on the PT secondary (:1330), so the primary ohms are the setting × PT ratio / CT ratio: line_drop_ohms with the CT ratio where it takes a CT primary rating (GridLAB-D's CT secondary is 1 A). ctRating is the same ratio in A (the CT primary rating on that 1 A secondary; clallum-models request 14, 2026-11-22), so the DSS exporter's CTprim gives back the dial volts. The settings are written on every unit that has them, also on MANUAL, where lineDropCompensation is false
S3c-5 Delays GridLAB-D waits dwell_time and then time_delay before every tap change, the first and each later one (regulator.cpp:598-611: a change re-arms the dwell, and the out-of-band branch then sets the mechanism time after it), so initialDelay = subsequentDelay = the sum. An exporter writes dwell_time 0 and time_delay = subsequentDelay
S3c-6 REMOTE_NODE Raises: a TapChangerControl.Terminal is a terminal, and a sense node is a bus with no single terminal to name; its one deck (IEEE13_houses) stops at the walk. As the DSS import's remote bus. Amended by S6-6: REMOTE_NODE on the regulator's own output is mapped as OUTPUT_VOLTAGE
S3c-7 Ratings Each 1-phase unit's OperationalLimitSet carries its own phase's ratings (6 Java-export regulators: 763.58 / 1041.25 A); a gang unit's are the link's, as S3a-5

Getter (done 2026-11-10, on this branch): the transformer getter's AUTO form reads an AutoTransformer with no mesh as ideal: no ratedS needed, an empty mesh, no core, and base_power the declared one, else None. One with a mesh still requires winding 1's ratedS. S3c's tests read every bound unit through the getter.

Tests. An atom tests/atoms/regulator/regulator.glm on the line atom: OUTPUT_VOLTAGE written CAB with a regulator tap_B, IEEE123's MANUAL CA unit (Type A, compensator settings), a LINE_DROP_COMP 1-phase unit with regulator_resistance, a BANK gang unit monitoring B, and an unused configuration; its golden, 10 fail-fast cases, the IEEE13_cdpsm golden, and on every deck the engine check (GLM-16): each unit's tap changer gives GridLAB-D's tap and step, its control GridLAB-D's band and enabled state, a unit per wired phase, and its ratedS and mesh as S3c-2 (amended 2026-11-22: the getter read no mesh before).

Expected differences from the DSS import of IEEE13 (GLM-16). Equal: three units AN/BN/CN on brkr→rg60, the taps 10/8/11, ±16 steps of 0.625 %, PT ratio 20, CT ratio 3500, the control on T2. Different, all from what GLM holds: ratedS 763.58 A × 2401.78 V = 1833.95 kVA (DSS 1666 kVA) and mesh r 1e-4 Ω, 0.0032 % (DSS 0.01 %; x 0.01 % on both, S3c-2); baseU/neutralU 2401.78 V (DSS 2.4 kV); enabled/controlEnabled false and no band (the Java export wrote MANUAL and commented the band out); lineDropR/X 0.0171 / 0.0514 Ω against DSS 0.0857 / 0.2571 Ω (the Java export copied the DSS dial volts with the DSS CT ratio 700 / 0.2 A, which GridLAB-D reads on a 1 A secondary); initialDelay 15 and subsequentDelay 15 (DSS 15 and 2: the export dropped tapdelay); ctRating 3500 A against DSS 700 A (the same Java ratio on a 1 A secondary); no reverse settings; mRIDs xf_xf_Reg_A against xf_reg1; the units carry limit sets.

Built (2026-11-09)

  • importer/cimtbl/regulator.py (map_regulators; FIELDS and CONFIGURATION_FIELDS), wired into MAPPING_ORDER (row 11, after the transformers) and CLASSIFIED (both classes).
  • Atom tests/atoms/regulator/regulator.glm with its golden; golden tests/goldens/IEEE13_cdpsm/regulator; the master golden's new Import; tests/test_cimtbl_regulator.py.
  • Every deck that binds S3b binds S3c: 27 of 29, the same two deck defects; 35 regulators as 102 units (33 3-phase, one 2-phase, one 1-phase).

Field tables (generated: fields_table(cls, records, fields=...), samples from tests/decks and the atom)

The object header and the link slots (as S3a) are left out.

regulator_configuration

RegulatorConfiguration field type samples kind target
name Union[str, RegulatorConfigurationName] rcon_reg3, rcon_creg1a, rcon_creg2a structural read by every regulator that names it; CIM has no regulator template, so nothing carries it but the units' row comments
connect_type Union[str, ForwardRef('ConnectType'), NoneType] WYE_WYE structural WYE_WYE (every unit wye, grounded); any other raises (regulator_configuration.cpp:232: NR takes WYE_WYE only)
band_center Optional[float] 7500.0, 2440.0, 122.0 derived targetValue = band_center (V): primary volts on OUTPUT_VOLTAGE and MANUAL, x power_transducer_ratio on LINE_DROP_COMP, whose band is on the PT secondary (regulator.cpp:1316)
band_width Optional[float] 120.0, 40.0, 2.0 derived targetDeadband = band_width (V): primary volts on OUTPUT_VOLTAGE and MANUAL, x power_transducer_ratio on LINE_DROP_COMP, whose band is on the PT secondary (regulator.cpp:1316); the full band, as CIM's
time_delay Optional[float] 30.0 derived initialDelay = subsequentDelay = dwell_time + time_delay (s): every tap change waits both (regulator.cpp:598-611, S3c-5); default 0
dwell_time Optional[float] 15.0 derived with time_delay; default 0
raise_taps Optional[int] 16 copied RatioTapChanger.highStep; also the stepVoltageIncrement divisor; 0 raises (regulator_configuration.cpp:198)
lower_taps Optional[int] 16 derived RatioTapChanger.lowStep = -lower_taps; 0 raises
current_transducer_ratio Optional[float] 3500.0, 250.0, 1500.0 copied RatioTapChanger.ctRatio, RatioTapChanger.ctRating (A); and the line drop's CT ratio; ctRating too: GridLAB-D's compensator takes amps on a 1 A CT secondary (regulator.cpp:1330), so the ratio is the CT primary rating in A
power_transducer_ratio Optional[float] 20.0 copied TapChangerControl.ptRatio, RatioTapChanger.ptRatio; and the line drop's and LINE_DROP_COMP band's PT ratio
compensator_r_setting_A Optional[float] 3.0, 0.4, 0.6 derived lineDropR (ohm) = the unit's phase setting x power_transducer_ratio / current_transducer_ratio (line_drop_ohms; regulator.cpp:1330); set without both ratios raises
compensator_r_setting_B Optional[float] 3.0, 1.4 derived lineDropR (ohm) = the unit's phase setting x power_transducer_ratio / current_transducer_ratio (line_drop_ohms; regulator.cpp:1330); set without both ratios raises
compensator_r_setting_C Optional[float] 3.0, 0.4, 0.2 derived lineDropR (ohm) = the unit's phase setting x power_transducer_ratio / current_transducer_ratio (line_drop_ohms; regulator.cpp:1330); set without both ratios raises
compensator_x_setting_A Optional[float] 9.0, 7.5, 0.4 derived lineDropX (ohm) = the unit's phase setting x power_transducer_ratio / current_transducer_ratio (line_drop_ohms; regulator.cpp:1330); set without both ratios raises
compensator_x_setting_B Optional[float] 9.0, 7.5, 2.6 derived lineDropX (ohm) = the unit's phase setting x power_transducer_ratio / current_transducer_ratio (line_drop_ohms; regulator.cpp:1330); set without both ratios raises
compensator_x_setting_C Optional[float] 9.0, 7.5, 0.4 derived lineDropX (ohm) = the unit's phase setting x power_transducer_ratio / current_transducer_ratio (line_drop_ohms; regulator.cpp:1330); set without both ratios raises
CT_phase Optional[str] B structural BANK: the phase whose compensator setting is read, which must be PT_phase; INDIVIDUAL: GridLAB-D ignores it (regulator.cpp:1328), listed on the row (S6)
PT_phase Optional[str] B structural BANK: TapChangerControl.monitoredPhase; INDIVIDUAL: GridLAB-D ignores it (regulator.cpp:1378), listed on the row (S6)
regulation Optional[float] 0.1 derived RatioTapChanger.stepVoltageIncrement = regulation / raise_taps (percent), GridLAB-D's tapChangePer (regulator.cpp:244); 0 raises unless MANUAL
control_level Optional[str] BANK structural INDIVIDUAL (default): one unit per wired phase; BANK: one gang unit on ABC (GLM-7), or one unit on its one PT_phase (S6)
Control Optional[str] MANUAL, OUTPUT_VOLTAGE, LINE_DROP_COMP structural MANUAL (default): enabled = controlEnabled = false; OUTPUT_VOLTAGE, LINE_DROP_COMP: true, lineDropCompensation on LINE_DROP_COMP only; REMOTE_NODE on the regulator's own to bus: as OUTPUT_VOLTAGE (the same voltages, regulator.cpp:1376-1420), elsewhere raises (S3c-6, S6)
reverse_flow_control Optional[str] structural unset or LOCK_NONE; others raises when set: no deck sets it, so a mapping waits for one
Type Optional[str] B, A mapped VoltageRegulator.construction; A -> typeA, B -> typeB (default B): GridLAB-D's ratio 1 / (1 + tap x step) or 1 - tap x step
tap_pos_A Optional[int] 10, 6, 0 derived RatioTapChanger.step of the phase's unit, unless the regulator's tap_A; default 0 (regulator.cpp:146)
tap_pos_B Optional[int] 8, 6, 4 derived RatioTapChanger.step of the phase's unit, unless the regulator's tap_B; default 0 (regulator.cpp:146)
tap_pos_C Optional[int] 11, 6, 0 derived RatioTapChanger.step of the phase's unit, unless the regulator's tap_C; default 0 (regulator.cpp:146)

regulator

Regulator field type samples kind target
name Union[str, RegulatorName] xf_Reg, xf_reg1a, xf_reg2 derived VoltageRegulator.name = name (BANK) or name_ (INDIVIDUAL); mRID = xf_ + that; the controls rc_ + that
phases Optional[str] CAB, ABC, A structural the wired phases A, B, C (N optional: every unit is wye to neutral); S raises
inrush_integration_method Optional[str] untranscribed inrush solver setting
status Optional[str] structural unset or CLOSED; OPEN raises (the walk)
from_node Optional[str] brkr, 150, 9 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] rg60, 150r, 9r structural node2: the root bus of the object it names (GLM-4)
inrush_convergence_value Optional[float] untranscribed inrush solver setting
inrush_integration_method_capacitance Union[str, ForwardRef('InrushIntegrationMethodCapacitance'), NoneType] untranscribed inrush solver setting
inrush_integration_method_inductance Union[str, ForwardRef('InrushIntegrationMethodInductance'), NoneType] untranscribed inrush solver setting
configuration Optional[str] rcon_reg3, rcon_creg1a, rcon_creg2a structural a regulator_configuration: its values on every unit
tap_A Optional[int] derived RatioTapChanger.step of the phase's unit (over tap_pos_A)
tap_B Optional[int] 3 derived RatioTapChanger.step of the phase's unit (over tap_pos_B)
tap_C Optional[int] derived RatioTapChanger.step of the phase's unit (over tap_pos_C)
msg_mode Optional[str] untranscribed co-simulation messaging
remote_voltage_A Union[dict, Complex, NoneType] untranscribed solver output or state
remote_voltage_B Union[dict, Complex, NoneType] untranscribed solver output or state
remote_voltage_C Union[dict, Complex, NoneType] untranscribed solver output or state
tap_A_change_count Optional[float] untranscribed solver output or state
tap_B_change_count Optional[float] untranscribed solver output or state
tap_C_change_count Optional[float] untranscribed solver output or state
sense_node Optional[str] structural REMOTE_NODE's monitored node: must solve as the regulator's to bus; on another Control GridLAB-D ignores it, listed on the row (S6)
regulator_resistance Optional[float] 0.001 copied TransformerMeshImpedance.r (ohm); GridLAB-D's series resistance, on every unit; default powerflow::default_resistance, 1e-4 ohm (S3c-2)

S4a: loads and capacitors (approved and built 2026-11-10)

S4a maps the loads (load, triplex_load, and the power of a plain triplex_node) and capacitor with its control (GLM-8), plan section 2 rows 12 and 13. GridLAB-D citations are to powerflow/load.cpp, triplex_load.cpp, triplex_node.cpp, node.cpp and capacitor.cpp. The user's calls (2026-11-10): S4a-2 approved with a TODO for the schedule, S4a-5 approved, S4a-8 option (a) ("breaking away from the sloppy java converter was the right call"). S4a-2 and S4a-5 amend GLM-8.

# artifact native class (records) CIM mRID
12 load.cimtbl load (1,532) EnergyConsumer + per-phase EnergyConsumerPhase values ld_<name>
12 triplex_load.cimtbl triplex_load (1) EnergyConsumer for the legs, a second for the 240 V part ld_<name>, ld_<name>_12
12 triplex_node.cimtbl triplex_node with power_1/_2/_12 (7,492) as triplex_load as triplex_load
13 capacitor.cimtbl capacitor (78) LinearShuntCompensator per unit (S4a-8), a RegulatingControl per controlled unit cap_<name>[_<phase>], cc_<name>[_<phase>]

A load or capacitor is itself a bus in GridLAB-D (S0's amendment of section 2), so each device sits on its record's root bus (GLM-4), and its BaseVoltage is that bus's. The bus is already in bus.cimtbl.

What the decks hold (the 28 readable decks): - load (1,532): - Given as constant power. 1,429 taxonomy loads give constant_power_X in VA, with load_class set and the parent a meter. - Given as base power with fractions. 103 Java-export loads (IEEE13_cdpsm, IEEE13_assets, IEEE123) give base_power_X ieeezipload.value*<|S| VA> with current_fraction_X 1 and current_pf_X. ieeezipload is the Java exporter's run-file schedule (GldNode.java:475); no deck defines it. - Not set anywhere: constant_current_X, constant_impedance_X, the explicit _AN/_AB forms, power_fraction_X, impedance_fraction_X, and a node's or meter's own power_X/current_X/shunt_X. - Phases: wye on 1-3 phases on 1,523 loads; ABCD 7 and BCD 2 are delta. - Triplex: power_12 on 7,492 taxonomy triplex_nodes, each the child of a triplex_meter. Nothing else in the power_1/current_*/shunt_* family is set. One triplex_load (IEEE13_cdpsm ld_house, BS) has base_power_1/_2 with current_fraction 1. - capacitor (78): - capacitor_X is in MVAr on 70 and VAr on 4. - control is VOLT 48, MANUAL 22, and unset (MANUAL) 8. - control_level is INDIVIDUAL (the default) everywhere it is set. - pt_phase is a single phase except ABCN on 2. - phases_connected is wye everywhere (ABC 47, ABCN 5, 1-2 phases 26); none is delta. - Switches: CLOSED on 32 (all three phases), unset on 45 (GridLAB-D's default OPEN), OPEN on 1 (IEEE13_assets cap1). - 24 taxonomy 1-phase capacitors also give capacitor_X on unconnected phases, which GridLAB-D ignores (capacitor.cpp:1447-1454). - No deck sets remote_sense, VAR/VARVOLT/CURRENT, a delta pt_phase, the *_deadband_center forms or lockout_time.

# IEEE13_cdpsm ld_670a (one GLM load on 670, three phases) and ld_692 (delta, only phase C = branch CA)
Table EnergyConsumer: mRID, name, node, phases, phaseConnection, grounded, p (W), q (VAr), LoadResponse, BaseVoltage, EquipmentContainer=fdr_IEEE13_cdpsm
    ld_ld_670a, ld_670a, 670, ABC, Y, true,  200000, 116000, zip_constant_i, bv_4p16kv
    ld_ld_692,  ld_692,  692, AC,  D, false, 170000, 151000, zip_constant_i, bv_4p16kv
Update Table EnergyConsumerPhase: mRID, p (W), q (VAr)
    ld_ld_670a_A, 17000,  10000                        # and _B 66 + 38j, _C 117 + 68j kVA
# taxonomy: power_12 on a triplex_node (240 V across the legs)
Table EnergyConsumer: ...
    ld_R1-12-47-1_tn_1_12, R1-12-47-1_tn_1_12, R1-12-47-1_tm_1, s1s2, D, false, 1530, 410, zip_constant_pq, bv_240v
# taxonomy VOLT capacitor, phases_connected ABC, pt_phase B, switches unset (OPEN), under S4a-8 (a)
Table LinearShuntCompensator: mRID, name, node, phases, phaseConnection, grounded, nomQ (VAr), nomU (V), bPerSection (VAr/V^2), sections, normalSections, maximumSections, BaseVoltage, EquipmentContainer
    cap_R1-12-47-1_cap_1_B, R1-12-47-1_cap_1_B, R1-12-47-1_node_422, B, Y, true, 300000, 7200, 0.00579, 0, 0, 1, ...
Table RegulatingControl: mRID, name, mode=voltage, discrete=true, enabled=true, monitoredPhase, targetValue, targetDeadband, Terminal
    cc_R1-12-47-1_cap_1_B, R1-12-47-1_cap_1_B, B, 7200, 200, cap_R1-12-47-1_cap_1_B_T1

(Values in the example are illustrative; the goldens hold the real ones.)

Slots (load, triplex_load, triplex_node)

GLM slot kind target
name derived EnergyConsumer.name; mRID ld_ + name (the 240 V part _12)
parent / the record structural node: the root bus (GLM-4)
phases structural wye unless it has D. phases on the consumer = the phases that carry power (S4a-1); S raises on a load
constant_power_X (power_1/_2/_12) copied the phase's p + jq, VA via pint; consumption is positive p
base_power_X + *_fraction_X + *_pf_X derived GridLAB-D's split at nominal voltage (S4a-3); a <schedule>.value*K base is K (S4a-2)
constant_current_X, constant_impedance_X, _AN/_AB forms structural raise when set (S4a-5)
load_class, load_priority untranscribed sorting only (load.cpp:518); load_priority is read by nothing
nominal_voltage structural the bus's (S1); not read again
measured_*, phase_loss_protection, inrush_*, frequency dependence untranscribed solver output or engine options

Slots (capacitor)

GLM slot kind target
name derived LinearShuntCompensator.name = name, or name_ for a per-phase unit (S4a-8); mRID cap_ + that, the control cc_ + that
phases_connected (else phases) structural the unit's phases, wye and grounded (S4a-11); D raises
capacitor_X derived in its written unit (one per unit); nomQ = the unit's sum, bPerSection = nomQ / nomU² in those units, (MVAr/V^2) (S4a-10); a phase not connected is dropped and listed in the row comment
cap_nominal_voltage derived nomU: the phase-to-neutral rating (else the bus's nominal_voltage, capacitor.cpp:376), × √3 on a 2- or 3-phase unit (CIM's line voltage)
switchA/B/C derived sections = normalSections = 1 CLOSED, 0 OPEN, default OPEN (S4a-9); maximumSections 1
control structural VOLT: a RegulatingControl (S4a-12); MANUAL (default): none; VAR, VARVOLT, CURRENT raise
control_level structural the units (S4a-8)
pt_phase structural which units the control switches; with D it raises
voltage_set_low, voltage_set_high derived targetValue = the midpoint, targetDeadband = high - low (band_from_on_off)
dwell_time, time_delay derived aVRDelay = dwell_time + time_delay (s), as S3c-5
remote_sense, remote_sense_B, *_deadband_center, *_deadband structural raise when set
VAr_set_*, current_set_*, lockout_time untranscribed read only by the unmapped modes
cap_X_switch_count untranscribed solver output

Fail fast (S4a)

The mapper raises on: - base_power_X and constant_power_X both set on one phase, since GridLAB-D keeps only the base form (load.cpp:984); - an expression other than <name>.value*<number>; - every unmapped form listed above; - a capacitor with no capacitance on a connected phase, or no cap_nominal_voltage and no bus voltage; - a gang unit whose phases' switch states or kVAr differ (S4a-8, S4a-10).

Decisions for S4a

# topic proposal
S4a-1 Load shape One EnergyConsumer per GLM load (GLM-8). A load with no power on any phase is a consumer of p = q = 0 on its wired phases (a split-phase record on s1s2), listed in the artifact header (amended 2026-11-16 for the Clallam decks, where every Milsoft consumer is a service: earlier it wrote only a bus; the draft raised). Each record is one service: customerCount 1 on its first consumer, unset on a split-phase record's 240 V part (defaulted: GLM has no customer count). Its phases are the phases that carry power. On wye these are the letters with a value. On delta they are the letters of the set branches: GLM's A/B/C on a D load are AB/BC/CA (node.cpp:2535), so ld_692's phase C is AC, as DSS's CA. An unset branch inside those letters gets 0. Wye is Y, grounded; delta is D, not grounded. p/q on the consumer are the totals. When its phase children differ, each gets an Update Table EnergyConsumerPhase row with its p and q (the binder's ld_x_A, or ld_x_AB on delta), which the load getter reads (split False). Equal children, and a single child (one delta branch such as ld_692's AC, or the 240 V part), get no rows: the consumer's total is the value. The load getter requires valued children to be the conductors, which one delta branch on two conductors is not, and an equal ABC load leaves phases blank, as the core load shape's balanced device
S4a-2 Schedule-scaled base (approved, with a TODO) <name>.value*K is K: CIM's p is the base, and a schedule only scales it over time, as DSS-11 keeps a load's kW and lists its load shape untranscribed. The reference goes in the row comment. Any other expression raises. This amends GLM-8, which said a scheduled base raises. Without it the three Java exports (103 loads) do not map. TODO (the user, 2026-11-10): map the schedule to the CGMES schedule classes (cim18v17 has ConformLoadSchedule and SeasonDayTypeSchedule) once profile export works again; it is broken today. Done 2026-11-21 (S8): a player is a ConformLoadGroup and its ConformLoadSchedule, its loads ConformLoads. Done 2026-11-21 (S9): a GLM schedule a base reads as <schedule>*K is a ConformLoadGroup with one ConformLoadSchedule per Season and DayType
S4a-3 Base power form As GridLAB-D does at nominal voltage (load.cpp:940-1073, triplex_load.cpp:410-731). Per part k (power, current, impedance), with pf defaulting to 1: P_k = base × f_k × |pf_k| and Q_k = P_k × √(1/pf_k² - 1), negative when pf_k < 0 (leading). pf_k = 0 gives P_k = 0 and Q_k = base × f_k. When the fractions don't sum to 1, the power fraction becomes 1 - I - Z (GridLAB-D's own repair, load.cpp:945), noted as defaulted:
S4a-4 Voltage response ZIP fractions from the load's totals (each part's P and Q over the totals). When every part is one kind, the shared zip_constant_pq/_i/_z row (core zip_fractions.cimtbl, which the master imports as DSS's does); otherwise a zip_<pP>_<pI>_<pZ>_<qP>_<qI>_<qZ> row in the artifact (GDM's naming; the mRID rounds the fractions to 6 places, the row holds them exactly, and two sets that round alike raise). When Q is 0, the Q fractions are the P fractions. Two artifacts that both use one mixed set would both write the row and fail to bind; no deck has a mixed set. Every deck is one kind: taxonomy constant power, Java exports constant current
S4a-5 Explicit current and impedance (approved) constant_current_X, constant_impedance_X, the _AN/_AB forms, and current_*/shunt_* on triplex nodes raise until a deck sets them. They carry angle conventions that no deck exercises: the current is relative to the nominal phasor (0/-120/+120, +30 on delta; solver_nr.cpp:9409), and triplex leg 2 has reversed polarity (node.cpp:1233). This amends GLM-8, which said they derive
S4a-6 Split phase _1 → s1 and _2 → s2 are 120 V legs to neutral: one consumer on s1s2 (or s1, s2), Y, grounded, as the core load shape and DSS's ld_house. _12 is 240 V across the legs: a second consumer ld_<name>_12 on s1s2, D, not grounded. The taxonomy has only _12, so one D consumer each
S4a-7 Artifacts One per native class: load.cimtbl, triplex_load.cimtbl, triplex_node.cimtbl (plain triplex_nodes that carry power). Load slots on any other bus class (node, meter, triplex_meter) raise
S4a-8 Capacitor units (option (a), the user's call) GridLAB-D switches each phase separately. Under INDIVIDUAL (the default, all 70 that set it), VOLT switches only the pt_phase phases, each on its own phase voltage (capacitor.cpp:1180-1205). The other phases stay at their initial state, by default OPEN. (a) Recommended, as S3c's INDIVIDUAL units: one unit per set of phases that switch together. MANUAL or unset is one gang unit, whose switch states must agree (raise otherwise, as S3a's per-phase switch states). Automatic INDIVIDUAL is one 1-phase unit per connected phase, cap_<name>_<phase>, with a control on the units whose phase is in pt_phase. BANK is one gang unit (no deck). Under (a), 34 taxonomy 3-phase capacitors with pt_phase B have phases A and C fixed OPEN, as GridLAB-D runs them, and only B switches. (b) One gang unit per capacitor, controlled on pt_phase, as a DSS CapControl would be: all three phases switch on B, which GridLAB-D does not do
S4a-9 Initial state sections = normalSections = the switch state as GridLAB-D starts it: 1 CLOSED, 0 OPEN, OPEN when unset (capacitor.cpp:151-195); never overridden. 45 taxonomy capacitors start OPEN
S4a-10 Rating nomQ = the sum of the unit's capacitor_X, in their written unit. nomU = cap_nominal_voltage (LN) × √3 on 2-3 phases, in its written unit. bPerSection = nomQ / nomU² in those units (kVAr/V^2: the units travel with the values, cimtables stores S; one table per unit pair), which the shunt getter reads back as Q = b × nomU² × sections; on one phase it is GridLAB-D's capacitor_X / Vc² (capacitor.cpp:394). Every gang unit in the decks is balanced, so no per-phase b is written; an unbalanced gang unit raises, and the shunt getter keeps its own raise
S4a-11 Connection phases_connected without D is wye, grounded, with or without N: GridLAB-D puts the shunt phase to ground either way. Ungrounded would change the physics on export. D raises (no deck; GridLAB-D's delta rates on LN², capacitor.cpp:1398)
S4a-12 VOLT control RegulatingControl mode voltage, discrete, enabled. It monitors the unit's own terminal (_T1) on the unit's phase (a gang unit's: pt_phase, one phase or raise). Target and deadband come from band_from_on_off(voltage_set_low, voltage_set_high) in primary volts, LN, with no PT: closes at or below low, opens at or above high (capacitor.cpp:1180). aVRDelay = dwell_time + time_delay, controlEnabled true, by the shunt shape's Update row. MANUAL has no control; any set points it carries go in the row comment

Cross-solver note on S4a-8 (the user asked for it, 2026-11-10, so capacitor controls can be checked across solvers): a GLM capacitor is mapped as GridLAB-D runs it, not as a DSS CapControl would. - Under option (a), the taxonomy's 3-phase VOLT capacitors with pt_phase B become three 1-phase units. Only B has a control; A and C stay at their initial state, OPEN when the deck doesn't set it. Exported to OpenDSS, that is three 1-phase capacitors and one CapControl on B: GridLAB-D's behaviour, kept. - Option (b), not taken, was one gang unit switched on B. That is what the DSS import of a DSS-authored deck gives, and likely what the taxonomy authors meant. - So on these 34 capacitors a GLM → CIM → DSS run and a DSS-native run of "the same" feeder are expected to differ: up to two thirds of each bank's kVAr, whenever B closes. - A cross-format check should compare per-phase switched kVAr against GridLAB-D's own solution, not against the DSS golden, and list these capacitors as an expected divergence. - MANUAL capacitors are one gang unit under both options, so they don't diverge.

Expected differences vs the DSS import of IEEE 13: - The Java export wrote every load as constant current (its ZIP option), where DSS has PQ, Z and I. - GLM holds one load per node: ld_670a carries 670a/b/c as phases. So the comparison is per node and phase: p and q agree to the Java export's 0.01 VA. - The house is s1s2, wye, 5 kW + 3.0987 kVAr in both. - The capacitors match: MANUAL and CLOSED, cap1 600 kVAr at 4.16 kV, cap2 100 kVAr at 2.4 kV.

Core work in S4a (plan section 7 rows 249-250): - The load shape gains an unbalanced example with Update Table EnergyConsumerPhase rows, a delta branch, and a 240 V s1s2 D consumer. - The shunt shape stays as is, since S4a-10 writes no per-phase b.

Tests. - An atom tests/atoms/load/load.glm on the line atom: - constant power on two wye phases; - a delta load on one branch; - the base form with mixed fractions and a negative pf, plus fractions that don't sum to 1; - a scheduled base; - a triplex_load with legs and _12; - a triplex_node power_12. - An atom tests/atoms/capacitor/capacitor.glm: - a MANUAL gang unit; - a VOLT INDIVIDUAL 3-phase capacitor with pt_phase B and switches unset; - a 1-phase VOLT capacitor with a value on an unconnected phase; - a BANK. - Goldens for both atoms and for IEEE13_cdpsm. - GridLAB-D's math against the bound objects on every deck: per-phase p and q from the native record, b × V² = capacitor_X, and controls on exactly the pt_phase units. - The fail-fast cases. - The deck sweep.

Built (2026-11-10)

  • Code:
  • importer/cimtbl/load.py: load, triplex_load and the plain triplex_node's power.
  • importer/cimtbl/capacitor.py.
  • bus.py: a bus's own load accumulators raise (BUS_LOAD, check_bus_loads), and a plain triplex_node's power_1/_2/_12 are now this slice's. classify takes a device's own slots.
  • The orchestrator imports the core zip_fractions.cimtbl, and lets a load's scheduled base through the expression guard (load.EXPRESSION_SLOTS).
  • Core: the load shape gained an unbalanced consumer with Update Table EnergyConsumerPhase rows and a 240 V s1s2 D consumer, with two getter tests. The shunt shape is unchanged, since S4a-10 writes no per-phase b.
  • Found at build:
  • A load with no power is a consumer of p = q = 0, listed in the header rather than raising (S4a-1, amended 2026-11-16).
  • A single delta branch and the 240 V part take no per-phase row: the load getter requires valued children to be the conductors.
  • A zip_ row holds its fractions exactly, and only its mRID is rounded (the getter checks the sum to 1e-6).
  • Each row comment lists only the device's own untranscribed values; its inherited bus slots (the solver's initial voltage_X) are counted once on the table comment.
  • Tests:
  • tests/test_cimtbl_load.py and tests/test_cimtbl_capacitor.py, with the atoms tests/atoms/load/ (load.glm, triplex.glm) and tests/atoms/capacitor/.
  • Goldens for the atoms and for IEEE13_cdpsm (load, triplex_load, capacitor).
  • Every deck reads through the core load, shunt and control getters, against GridLAB-D's formulas written out again in the test.
  • Results:
  • 412 GLM tests pass with --roundtrip over every deck.
  • 27 decks bind; the same two deck defects stop the other two.
  • The decks give 9,025 consumers, 162 capacitor units (34 closed at start) and 46 VOLT controls.
  • IEEE13_cdpsm matches the DSS golden per node and phase to the Java export's 0.01 VA. Its two capacitors equal DSS's.

Field tables (generated: fields_table(cls, records, fields=OWN), samples from tests/decks and the atoms)

load (its own slots; its bus slots are S1's, with the load accumulators raising, S4a-7)

Load field type samples kind target
load_class Optional[str] I, C, R untranscribed for sorting only (load.cpp:518)
load_priority Optional[str] untranscribed read by nothing in powerflow
constant_power_A Union[dict, Complex, NoneType] Complex({'real': 585277.7504, 'imag':..., Complex({'real': 0.0, 'imag': 0.0}), Complex({'real': 110387.6944, 'imag':... copied EnergyConsumer.p (VA), EnergyConsumer.q (VA); the phase's p + jq, VA via pint; with base_power_X raises
constant_power_B Union[dict, Complex, NoneType] Complex({'real': 596917.157, 'imag': ..., Complex({'real': 9908.4297, 'imag': 3..., Complex({'real': 19800.0, 'imag': 600... copied EnergyConsumer.p (VA), EnergyConsumer.q (VA); the phase's p + jq, VA via pint; with base_power_X raises
constant_power_C Union[dict, Complex, NoneType] Complex({'real': 592476.6189, 'imag':..., Complex({'real': 54848.3315, 'imag': ..., Complex({'real': 16454.4994, 'imag': ... copied EnergyConsumer.p (VA), EnergyConsumer.q (VA); the phase's p + jq, VA via pint; with base_power_X raises
constant_power_A_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_B_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_C_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_A_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_B_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_C_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_A Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_B Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_C Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_A_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_B_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_C_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_A_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_B_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_C_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_A Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_B Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_C Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_A_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_B_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_C_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_A_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_B_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_C_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_AN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_BN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_CN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_AN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_BN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_CN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_AN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_BN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_CN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_AN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_BN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_CN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_AN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_BN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_CN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_AN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_BN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_CN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_AN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_BN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_CN Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_AN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_BN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_CN_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_AN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_BN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_CN_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_AB Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_BC Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_CA Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_AB_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_BC_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_CA_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_AB_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_BC_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_CA_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_AB Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_BC Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_CA Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_AB_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_BC_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_CA_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_AB_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_BC_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_CA_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_AB Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_BC Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_CA Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_AB_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_BC_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_CA_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_AB_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_BC_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_CA_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
measured_voltage_A Union[dict, Complex, NoneType] untranscribed solver output
measured_voltage_B Union[dict, Complex, NoneType] untranscribed solver output
measured_voltage_C Union[dict, Complex, NoneType] untranscribed solver output
measured_voltage_AB Union[dict, Complex, NoneType] untranscribed solver output
measured_voltage_BC Union[dict, Complex, NoneType] untranscribed solver output
measured_voltage_CA Union[dict, Complex, NoneType] untranscribed solver output
phase_loss_protection Union[bool, Bool, NoneType] untranscribed engine option
measured_power_A Union[dict, Complex, NoneType] untranscribed solver output
measured_power_B Union[dict, Complex, NoneType] untranscribed solver output
measured_power_C Union[dict, Complex, NoneType] untranscribed solver output
measured_power Union[dict, Complex, NoneType] untranscribed solver output
base_power_A Optional[float] 100.0 derived GridLAB-D's split at nominal voltage (S4a-3): P = base x fraction x
base_power_B Optional[float] derived GridLAB-D's split at nominal voltage (S4a-3): P = base x fraction x
base_power_C Optional[float] 50000.0 derived GridLAB-D's split at nominal voltage (S4a-3): P = base x fraction x
power_pf_A Optional[float] 0.9 derived with base_power; default 1
current_pf_A Optional[float] 0.824042, 0.83005, 0.861934 derived with base_power; default 1
impedance_pf_A Optional[float] derived with base_power; default 1
power_pf_B Optional[float] derived with base_power; default 1
current_pf_B Optional[float] 0.8, 0.805651, 0.867313 derived with base_power; default 1
impedance_pf_B Optional[float] derived with base_power; default 1
power_pf_C Optional[float] derived with base_power; default 1
current_pf_C Optional[float] 0.904819, 0.8, 0.864582 derived with base_power; default 1
impedance_pf_C Optional[float] derived with base_power; default 1
power_fraction_A Optional[float] 0.5 derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
current_fraction_A Optional[float] 1.0, 0.3 derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
impedance_fraction_A Optional[float] 0.2 derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
power_fraction_B Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
current_fraction_B Optional[float] 1.0 derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
impedance_fraction_B Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
power_fraction_C Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
current_fraction_C Optional[float] 1.0, 0.6 derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
impedance_fraction_C Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
inrush_integration_method_capacitance Optional[str] untranscribed engine option
inrush_integration_method_inductance Optional[str] untranscribed engine option

triplex_load (its own slots; its bus slots are S1's, with the load accumulators raising, S4a-7)

TriplexLoad field type samples kind target
load_class Union[str, ForwardRef('LoadClass'), NoneType] untranscribed for sorting only (load.cpp:518)
load_priority Union[str, ForwardRef('LoadPriority'), NoneType] untranscribed read by nothing in powerflow
constant_power_1 Union[dict, Complex, NoneType] Complex({'real': 2500.0, 'imag': 1000... copied EnergyConsumer.p (VA), EnergyConsumer.q (VA); the phase's p + jq, VA via pint; with base_power_X raises
constant_power_2 Union[dict, Complex, NoneType] Complex({'real': 2000.0, 'imag': 800.0}) copied EnergyConsumer.p (VA), EnergyConsumer.q (VA); the phase's p + jq, VA via pint; with base_power_X raises
constant_power_12 Union[dict, Complex, NoneType] Complex({'real': 4000.0, 'imag': 1500... copied EnergyConsumer.p (VA), EnergyConsumer.q (VA); the phase's p + jq, VA via pint; with base_power_X raises
constant_power_1_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_2_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_12_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_1_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_2_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_power_12_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_1 Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_2 Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_12 Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_1_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_2_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_12_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_1_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_2_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_current_12_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_1 Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_2 Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_12 Union[dict, Complex, NoneType] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_1_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_2_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_12_real Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_1_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_2_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
constant_impedance_12_reac Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (S4a-5)
measured_voltage_1 Union[dict, Complex, NoneType] untranscribed solver output
measured_voltage_2 Union[dict, Complex, NoneType] untranscribed solver output
measured_voltage_12 Union[dict, Complex, NoneType] untranscribed solver output
indiv_measured_power_1 Union[dict, Complex, NoneType] untranscribed solver output
indiv_measured_power_2 Union[dict, Complex, NoneType] untranscribed solver output
indiv_measured_power_12 Union[dict, Complex, NoneType] untranscribed solver output
measured_power Union[dict, Complex, NoneType] untranscribed solver output
base_power_1 Optional[float] derived GridLAB-D's split at nominal voltage (S4a-3): P = base x fraction x
base_power_2 Optional[float] derived GridLAB-D's split at nominal voltage (S4a-3): P = base x fraction x
base_power_12 Optional[float] derived GridLAB-D's split at nominal voltage (S4a-3): P = base x fraction x
power_pf_1 Optional[float] derived with base_power; default 1
current_pf_1 Optional[float] 0.85 derived with base_power; default 1
impedance_pf_1 Optional[float] derived with base_power; default 1
power_pf_2 Optional[float] derived with base_power; default 1
current_pf_2 Optional[float] 0.85 derived with base_power; default 1
impedance_pf_2 Optional[float] derived with base_power; default 1
power_pf_12 Optional[float] derived with base_power; default 1
current_pf_12 Optional[float] derived with base_power; default 1
impedance_pf_12 Optional[float] derived with base_power; default 1
power_fraction_1 Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
current_fraction_1 Optional[float] 1.0 derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
impedance_fraction_1 Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
power_fraction_2 Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
current_fraction_2 Optional[float] 1.0 derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
impedance_fraction_2 Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
power_fraction_12 Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
current_fraction_12 Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1
impedance_fraction_12 Optional[float] derived with base_power; default 0, the power fraction 1 - I - Z when they don't sum to 1

capacitor (its own slots; its bus slots are S1's, with the load accumulators raising, S4a-7)

Capacitor field type samples kind target
pt_phase Optional[str] ABCN, A, B structural VOLT: the units that get a control (INDIVIDUAL) or the gang unit's monitored phase (BANK); D raises
phases_connected Optional[str] ABCN, CN, AN structural the connected phases (else phases): wye, grounded with or without N (S4a-11); D raises
switchA Optional[str] CLOSED, OPEN derived sections = normalSections: 1 CLOSED, 0 OPEN; default OPEN (S4a-9); a gang unit's must agree
switchB Optional[str] CLOSED, OPEN derived sections = normalSections: 1 CLOSED, 0 OPEN; default OPEN (S4a-9); a gang unit's must agree
switchC Optional[str] CLOSED, OPEN derived sections = normalSections: 1 CLOSED, 0 OPEN; default OPEN (S4a-9); a gang unit's must agree
control Union[str, ForwardRef('Control'), NoneType] VOLT structural VOLT: a RegulatingControl; MANUAL (default): none; VAR, VARVOLT, CURRENT raise
cap_A_switch_count Optional[float] untranscribed solver output
cap_B_switch_count Optional[float] untranscribed solver output
cap_C_switch_count Optional[float] untranscribed solver output
voltage_set_high Optional[float] 2500.0, 2600.0, 7300.0 derived targetValue = the midpoint, targetDeadband = high - low (band_from_on_off); opens at or above it
voltage_set_low Optional[float] 1950.0, 2050.0, 7200.0 derived with voltage_set_high; closes at or below it
voltage_deadband_center Optional[float] structural raises when set: no deck sets it, so a mapping waits for one
voltage_deadband Optional[float] structural raises when set: no deck sets it, so a mapping waits for one
VAr_set_high Optional[float] untranscribed read only by the VAR, VARVOLT and CURRENT modes
VAr_set_low Optional[float] untranscribed read only by the VAR, VARVOLT and CURRENT modes
VAr_deadband_center Optional[float] structural raises when set: no deck sets it, so a mapping waits for one
VAr_deadband Optional[float] structural raises when set: no deck sets it, so a mapping waits for one
current_set_low Optional[float] untranscribed read only by the VAR, VARVOLT and CURRENT modes
current_set_high Optional[float] untranscribed read only by the VAR, VARVOLT and CURRENT modes
current_deadband_center Optional[float] structural raises when set: no deck sets it, so a mapping waits for one
current_deadband Optional[float] structural raises when set: no deck sets it, so a mapping waits for one
capacitor_A Optional[float] 200000.0, 0.3, 0.25 derived in its written unit: nomQ = the unit's sum, bPerSection = nomQ / nomU^2 (S4a-10); on a phase not connected: dropped, GridLAB-D ignores it (capacitor.cpp:1447)
capacitor_B Optional[float] 200000.0, 0.3, 0.25 derived in its written unit: nomQ = the unit's sum, bPerSection = nomQ / nomU^2 (S4a-10); on a phase not connected: dropped, GridLAB-D ignores it (capacitor.cpp:1447)
capacitor_C Optional[float] 200000.0, 100000.0, 0.3 derived in its written unit: nomQ = the unit's sum, bPerSection = nomQ / nomU^2 (S4a-10); on a phase not connected: dropped, GridLAB-D ignores it (capacitor.cpp:1447)
cap_nominal_voltage Optional[float] 2401.78, 2400.0, 2402.0 derived nomU: the phase-to-neutral rating (else nominal_voltage, capacitor.cpp:376), x sqrt 3 on 2-3 phases
time_delay Optional[float] 0.0, 300.0, 30.0 derived aVRDelay = dwell_time + time_delay (s), as S3c-5
dwell_time Optional[float] 0.0, 30.0, 15.0 derived with time_delay
lockout_time Optional[float] untranscribed read only by VARVOLT
remote_sense Optional[str] structural raises when set: no deck sets it, so a mapping waits for one
remote_sense_B Optional[str] structural raises when set: no deck sets it, so a mapping waits for one
control_level Union[str, ForwardRef('ControlLevel'), NoneType] INDIVIDUAL, BANK structural the units (S4a-8): INDIVIDUAL (default) VOLT is a unit per phase

S4b: inverters, solar and batteries (approved and built 2026-11-10)

S4b maps inverter with its nested solar or battery (GLM-13), plan section 2 row 14. GridLAB-D citations are to generators/inverter.cpp, solar.cpp and battery.cpp.

The user's calls (2026-11-10): - S4b-2: follow GridLAB-D's logic. The output is what GridLAB-D computes, not the P_Out the Java export wrote. The PV's irradiance goes on PhotoVoltaicUnit.irradiance (an SSH extension, added to cim18v17 the same day) and its panel data on SolarArrayInfo/SolarPanelInfo. - A battery under CONSTANT_PF is a Java export defect: GridLAB-D never dispatches it (S4b-2). It is read as CONSTANT_PQ, the mode the Java export meant, whose set point is P_Out. - S4b-5: ratedU is the real line-to-line voltage, matching the transformer's PowerTransformerEnd.ratedU and the bus's BaseVoltage.nominalVoltage (line to line). Asked whether GridLAB-D tells a wye inverter from a delta one, which would put a wye inverter at 120 V: it has no delta inverter (phases takes A, B, C, N and S only, inverter.cpp:260-265). - A, B, C: wye, injecting on voltage_A/_B/_C (:897). - Split phase: connected across the legs, on voltage_12/current_12 at 240 V (:861, :871). That is s1s2 D (S4b-4), as S4a-6's 240 V load part, so its ratedU is 240 V, not a 120 V leg. - The control modes are described, at least as capabilities, by InverterCapabilities.

The user rebuilt cim18v17 the same day. It adds PhotoVoltaicUnit.irradiance, the InverterInfo and GridEdgeDeviceInfo attributes, and InverterInfo.InverterCapabilities (its typo is fixed and reported upstream).

# artifact native class (records) CIM mRID
14 inverter.cimtbl inverter (5) with its solar (2) or battery (3) PowerElectronicsConnection + PhotoVoltaicUnit or BatteryUnit; the datasheets below pv_<inverter> / storage_<inverter>, the unit <connection>_unit

Datasheets (PowerSystemResource.AssetDatasheet, the GDM import's pattern): - The inverter: GenerationInverterInfo (under PV) or StorageInverterInfo (under a battery), <connection>_info. It holds apparentPowerMaximum = ratedS, reactivePowerInjectedMax/AbsorbedMax = ratedS, and on storage chargeRateActiveMax = max_charge_rate. - Its capabilities: InverterCapabilities by S4b-11. Not written yet: cim-tables cannot reference an Identity row (amended at build, below); the flag goes in the row comment. - The solar: a SolarArrayInfo <connection>_array (tiltAngle, orientationAzimuth, shadingFactor) with one SolarPanelInfo <connection>_panel (efficiency, referenceIrradiation = Rated_Insolation, referenceTemperature = 25 °C, the 77 °F GridLAB-D's temperature correction is relative to). The PhotoVoltaicUnit's AssetDatasheet is the array. - The battery: a BatteryInfo <connection>_battery with batteryType (LI_ION → lithiumIon, LEAD_ACID → leadAcid), ratedCapacity = battery_capacity, and numberOfCells = floor(nominal_voltage / 4.1) on LI_ION (GridLAB-D's n_series, battery.cpp:720).

InverterCapabilities is an Identity, not an IdentifiedObject; whether the binder takes it as a row, and BatteryInfo.ratedCapacity's unit, are to be checked at build.

An inverter sits on its parent's root bus (GLM-4), whose BaseVoltage is already in bus.cimtbl. Its solar or battery is its child: the reader gives it parent = <inverter>, and GridLAB-D requires a battery's parent to be an inverter (battery.cpp:657).

What the decks hold (the 28 readable decks): - IEEE13_cdpsm (Java export from the DSS IEEE 13 with DER) has 5 inverters: - Solar: inv_pv_school (ABCN) and inv_pv_house (BS), each with a solar. - Batteries: inv_bat_school, inv_bat_batidle (ABCN) and inv_bat_house (BS), each with a battery. - Settings: all are FOUR_QUADRANT, CONSTANT_PF, power_factor ±1, generator_status ONLINE, inverter_efficiency 1.0 (PV) or 0.975 (storage). - Ratings and dispatch: rated_power is written per phase. V_base is 480 or 208, and P_Out is the Java export's snapshot. - The solars: SINGLE_CRYSTAL_SILICON, efficiency 0.2, derating/soiling 1, rated_power. No area, no climate object, so GridLAB-D runs on static weather. - The batteries: each gives battery_capacity, state_of_charge, round_trip_efficiency 0.86, rated_power, nominal_voltage 48, LI_ION and the internal model. Their inverters set generator_mode CONSTANT_PQ, sense_object and the load-following thresholds, which CONSTANT_PF does not read. - IEEE123_transactive has 5 CONSTANT_PQ inverters, but its Object battery lines stop it at the reader: a defect in the deck itself, since GridLAB-D's loader is case-sensitive (gldcore/load.cpp:1393). - Not set anywhere: other inverter types, other four_quadrant_control_modes, use_multipoint_efficiency TRUE, climate, other SOLAR_POWER_MODELs or tilt models, diesel_dg, windturb_dg, energy_storage and inverter_dyn.

# IEEE13_cdpsm under S4b-2: GridLAB-D's static-weather PV output; the house battery read as CONSTANT_PQ (charging)
Table PowerElectronicsConnection: mRID, name, node, phases, phaseConnection, ratedS (VA), ratedU (V), p (W), q (VAr), maxQ (VAr), minQ (VAr), normallyInService, AssetDatasheet, BaseVoltage, EquipmentContainer=fdr_IEEE13_cdpsm
    # P_Out as written (GridLAB-D recomputes it): 240000 W
    pv_inv_pv_school,      inv_pv_school, 634,   ,     Y, 300000, 480, -298254.5, 0, 300000, -300000, true, pv_inv_pv_school_info,      bv_480v
    # four_quadrant_control_mode CONSTANT_PF read as CONSTANT_PQ (a Java export defect: GridLAB-D never dispatches a CONSTANT_PF battery)
    storage_inv_bat_house, inv_bat_house, house, s1s2, D, 5000,   240, 5000,      0, 5000,   -5000,   true, storage_inv_bat_house_info, bv_240v
Table PhotoVoltaicUnit: mRID, name, maxP (W), minP (W), irradiance (W/m^2), AssetDatasheet, PowerElectronicsConnection, EquipmentContainer=...
    pv_inv_pv_school_unit, pv_school, 300000, 0, 1000, pv_inv_pv_school_array, pv_inv_pv_school
Table BatteryUnit: mRID, name, ratedE (Wh), storedE (Wh), minimumE (Wh), maxP (W), minP (W), chargingEfficiency (percent), dischargingEfficiency (percent), batteryState, AssetDatasheet, PowerElectronicsConnection, EquipmentContainer=...
    storage_inv_bat_house_unit, bat_house, 13500, 5000.4, 0, 5000, -5000, 92.736, 92.736, charging, storage_inv_bat_house_battery, storage_inv_bat_house

(The example values are illustrative; the goldens will hold the real ones.)

GridLAB-D's static-weather PV output (S4b-2)

With no climate object, the default tilt model (DEFAULT) and the default SOLAR_POWER_MODEL (BASEEFFICIENT), GridLAB-D's snapshot is a closed form: - Insolation: Insolation = Rated_Insolation × shading_factor (solar.cpp:1170). By default that is 92.902 W/sf = 1000 W/m² × 1, and it goes on PhotoVoltaicUnit.irradiance (W/m² via pint). - Module temperature: Tmodule = Tamb + (NOCT - 68) / 74.32 × Insolation, with Tamb = 59 °F (static, solar.cpp:321) and NOCT = 118.4 °F by default. - DC output: P_DC = rated_power × Insolation / Rated_Insolation × (1 + Pmax_temp_coeff × (Tmodule - 77)) × derating × soiling (solar.cpp:1220). Pmax_temp_coeff defaults by panel_type; SINGLE_CRYSTAL_SILICON's is -0.00437 / 33.8 per °F (solar.cpp:563). - AC output: the inverter's P_DC × inverter_efficiency (inverter.cpp:3290), with each phase capped at rated_power: |S| ≤ p_max = phases out × rated_power (:1415-1427, :3798). p = -(that) in the load sign.

For IEEE 13: Tmodule = 122.0 °F, the factor is 0.99418, so pv_school gives -298.25 kW (P_Out written -240) and pv_house -4.97 kW (written -4). The slots this uses with no CIM home (NOCT, Pmax_temp_coeff, derating, soiling, inverter_efficiency) are listed as derived into p. A climate object, FIXED_AXIS and the other power models raise: they need GridLAB-D's weather and solar position (no deck).

Slots (inverter)

GLM slot kind target
name derived PowerElectronicsConnection.name; mRID pv_/storage_ + name by its unit (S4b-6)
parent structural node: the root bus (GLM-4)
phases structural 3 phases: blank (balanced, no children); 1-2 phases: the letters, Y; S: s1s2 D (S4b-4). GridLAB-D has no D keyword on an inverter
inverter_type structural FOUR_QUADRANT; any other raises (S4b-1). Unset is GridLAB-D's PWM (inverter.cpp:1350), which also raises
four_quadrant_control_mode structural dispatch: CONSTANT_PF (the default, inverter.cpp:515) on a solar, CONSTANT_PQ on a battery, which also takes CONSTANT_PF as the Java defect (S4b-1, S4b-2); others raise. Capability: S4b-11, the mode as read
rated_power derived ratedS = rated_power × phases out: 3, 2, or 1 (S counts as 1; inverter.cpp:1318-1326, :1415); the per-phase cap of S4b-2; apparentPowerMaximum. Unset or 0 raises: GridLAB-D silently uses 25 kVA (:1409)
inverter_efficiency derived into p (S4b-2); CIM has no inverter efficiency. Unset, 0 or negative is GridLAB-D's 0.9 (:1398)
P_Out derived battery: the set point, p = -P_Out after GridLAB-D's CONSTANT_PQ limits (S4b-2). Solar: GridLAB-D overwrites it in CONSTANT_PF (inverter.cpp:433, :3879), so it is only listed in the row comment
power_factor derived CONSTANT_PF: q = 0 when |pf| = 1; |pf| < 1 raises (S4b-3). Not read by CONSTANT_PQ, so on a battery read as CONSTANT_PQ it goes in the row comment
Q_Out derived CONSTANT_PQ: q = 0 when unset or 0; any other value raises (S4b-3)
V_base untranscribed read only by the volt-var and volt-watt modes (inverter.cpp:318); ratedU is the bus's line-to-line voltage (S4b-5)
generator_status derived normallyInService: ONLINE (default) true, OFFLINE false
soc_reserve derived BatteryUnit.minimumE = soc_reserve × battery_capacity; default 0
max_charge_rate copied StorageInverterInfo.chargeRateActiveMax (W via pint)
generator_mode, sense_object, charge_*/discharge_*_threshold, *_lockout_time, max_discharge_rate untranscribed read only by load following and the non-four-quadrant types, which raise (to be verified slot by slot at build)
volt-var, volt-watt, VSI, frequency-watt, group-PF, multipoint-efficiency and dynamic slots untranscribed or raises their modes raise for the dispatch. use_multipoint_efficiency TRUE raises
solver state (VA_Out, I_In, phaseA_I_Out, ...) untranscribed solver output

Slots (solar, battery)

GLM slot kind target
solar name derived PhotoVoltaicUnit.name; mRID <connection>_unit
solar rated_power derived maxP (W via pint), minP 0, and P_DC (S4b-2). Unset raises (GridLAB-D derives it from area and insolation, solar.cpp:606)
solar Rated_Insolation, shading_factor derived irradiance (S4b-2); SolarPanelInfo.referenceIrradiation; SolarArrayInfo.shadingFactor (percent)
solar efficiency copied SolarPanelInfo.efficiency (percent); default by panel_type (solar.cpp:561)
solar tilt_angle, orientation_azimuth copied SolarArrayInfo.tiltAngle, orientationAzimuth (defaults 45, 180: solar.cpp:195)
solar NOCT, Pmax_temp_coeff, derating, soiling, panel_type derived into p (S4b-2)
solar SOLAR_POWER_MODEL, orientation, weather structural the defaults (BASEEFFICIENT, DEFAULT, none); others raise
solar DC and other model slots (area, Voc, V_Max, PV_CURVE parameters, ...) untranscribed DC side, read by no mapped path
battery name derived BatteryUnit.name; mRID <connection>_unit
battery battery_capacity derived ratedE (Wh via pint), BatteryInfo.ratedCapacity
battery state_of_charge derived storedE = state_of_charge × battery_capacity
battery rated_power derived maxP = rated_power, minP = -rated_power (the generation sign, as the DER getter reads it)
battery round_trip_efficiency derived chargingEfficiency = dischargingEfficiency = √round_trip_efficiency, in percent: GridLAB-D applies its square root each way (battery.cpp:2220, :2230). Default by rfb_size, else 0.8 (battery.cpp:661-708)
battery battery_type, nominal_voltage derived BatteryInfo.batteryType, numberOfCells
battery use_internal_battery_model structural true; false raises (the legacy model, no deck)
battery internal-model curve and DC slots untranscribed DC side; CIM has none

Fail fast (S4b)

The mapper raises on: - an inverter with no solar or battery, or with more than one; - a solar or battery whose parent is not an inverter; - every unmapped type, mode and solar model listed above, and a climate object; - rated_power unset or 0 on an inverter or a solar; - |power_factor| < 1 under CONSTANT_PF, or a non-zero Q_Out under CONSTANT_PQ; - a battery with no battery_capacity; - CONSTANT_PQ on a solar (no deck: GridLAB-D then caps P at the panel's output).

Decisions for S4b

# topic proposal
S4b-1 Modes (dispatch) FOUR_QUADRANT only. A solar runs CONSTANT_PF; a battery runs CONSTANT_PQ, or CONSTANT_PF read as CONSTANT_PQ (the Java defect, S4b-2). IEEE123_transactive's CONSTANT_PQ batteries would take the same path, but that deck stops at the reader. Every other type and mode raises for the dispatch until a deck has one, as S4a-5; S4b-11 still describes its capability
S4b-2 The dispatch (the user's calls: GridLAB-D's logic; the battery mode a Java defect) PV: GridLAB-D's static-weather output (the section above), with the irradiance on PhotoVoltaicUnit.irradiance; the written P_Out is listed in the row comment. Battery: GridLAB-D's CONSTANT_PQ (inverter.cpp:3485-3555). The set point is P_Out (generation positive), set to 0 when charging a full battery (soc ≥ 1) or discharging at or below soc_reserve, and capped at ratedS; p = -that. A battery whose inverter says CONSTANT_PF is read as CONSTANT_PQ, with a row comment: under CONSTANT_PF GridLAB-D would never dispatch it. The inverter takes P from its DC input V_In × I_In, the internal battery writes back only battery_soc (battery.cpp:891), and the inverter asks for power (power_in) only in CONSTANT_PQ, VSI and load following (inverter.cpp:3545, :3716, :3865). The Java export wrote CONSTANT_PF on all three IEEE 13 batteries with P_Out as their dispatch: a producer defect (to report upstream), corrected here by the user's call
S4b-3 q CONSTANT_PF: q = 0 when |pf| = 1 (all 5); |pf| < 1 raises. The sign of GridLAB-D's Q there is "treat like a normal load right now" (inverter.cpp:3466-3475), and no deck checks it
S4b-4 Phases GridLAB-D has no delta inverter (no D keyword, inverter.cpp:260-265). On A, B and C it is wye to neutral (voltage_A/_B/_C, :897): Y, grounded; 3 phases blank, CIM's balanced default, as the core der shape. Split phase S puts the whole output across the legs (power_val[0] on voltage_12/current_12, :861, :871, :3432): s1s2 D, as S4a-6's 240 V load part. The core shape's p2 and the DSS golden's pv_house say s1s2 Y, two 120 V legs to neutral, which GridLAB-D's inverter is not
S4b-5 ratedU (the user's call) Line to line, the root bus's BaseVoltage.nominalVoltage, which matches the transformer's ratedU. 3-phase wye at 634: 480 V. Split phase across the legs: 240 V. That is the voltage it sits across, so a wye reading of 120 V does not apply (S4b-4). A 1- or 2-phase wye inverter is also its bus's line-to-line voltage, the core DER getter's convention (a 1-phase wye device's kV × √3). V_base (480, 208) is untranscribed
S4b-6 Shape and names One PowerElectronicsConnection per inverter with its one unit. A hybrid (solar and battery under one inverter) raises: GridLAB-D has no such model. mRID pv_<inverter> or storage_<inverter> and <connection>_unit, the DSS import's prefixes; the datasheets <connection>_info, _capabilities, _array, _panel, _battery; names as written
S4b-7 q limits, fault current maxQ = ratedS, minQ = -ratedS: GridLAB-D's four-quadrant inverter caps |S| at p_max = phases out × rated_power (inverter.cpp:3798), as the DSS golden does. maxIFault is blank: GLM has no fault current in CONSTANT_PF
S4b-8 Battery state batteryState from the dispatch: discharging below 0 (load sign), charging above, waiting at 0. IEEE 13: school discharging (-100 kW), house charging (+5 kW), batidle charging (+1 kW: the Java export wrote DSS's idle loss as a charge). idlingP is blank: GLM has none
S4b-9 Battery values ratedE = battery_capacity, storedE = soc × capacity, minimumE = the inverter's soc_reserve × capacity (default 0), maxP/minP = ±battery rated_power, efficiencies √round_trip each way
S4b-10 Order MAPPING_ORDER gains inverter after capacitor. It references only buses and its own datasheets
S4b-11 Capabilities InverterCapabilities holds the four_quadrant_control_mode as read (S4b-2: a Java-defect battery is CONSTANT_PQ) as a capability flag: CONSTANT_PF → isModeCapableConstantPowerFactor, CONSTANT_PQ → isModeCapableActivePowerReactivePower, VOLT_VAR → isModeCapableVoltageReactivePower, VOLT_WATT → isModeCapableVoltageActivePower, VOLT_VAR_FREQ_PWR → the volt-var and frequency-watt flags. LOAD_FOLLOWING, GROUP_LF and VSI have no IEEE 1547 flag, so none is set. GridLAB-D runs one mode per inverter, so the other flags are left unset, not false

Cross-solver note on S4b-2, S4b-4 and S4b-5: the GLM artifacts follow GridLAB-D, so the IEEE 13 DER differ from the DSS golden (cimhub_opendss/tests/goldens/IEEE13_CDPSM/{pvsystem,storage}.cimtbl): - PV p: -298.25 vs -240 kW on the school and -4.97 vs -4 kW on the house. GridLAB-D's static weather is full sun at 122 °F; DSS's irradiance multiplier gives 80 %. - Battery p: equal (-100, +5, +1 kW; the school to 0.001 W, GridLAB-D's cap at 3 × 33333.333 VA), since the batteries are read as CONSTANT_PQ (S4b-2). But batidle is charging at 1 kW, where DSS says waiting with a 1 kW idling loss. - House inverters: s1s2 D at 240 V vs DSS's s1s2 Y at 208 V. The DSS exporter must write a 240 V split-phase DER across the legs. - Battery values: minimumE 0 vs 40 kWh, efficiencies 92.7 % vs 90 %, idlingP blank vs 1 kW. - Equal: node, ratedS, q, maxQ/minQ, PV maxP/minP, ratedE, storedE and battery maxP/minP.

A cross-format check should list these as expected divergences, as for S4a-8's capacitors. The core der shape's p2 (s1s2 Y, 208 V) should follow S4b-4/-5: a core follow-up (plan section 7).

Built (2026-11-10)

  • Code:
  • importer/cimtbl/inverter.py: the inverter with its solar or battery, the datasheets, and GridLAB-D's output (pv_output, battery_output). All 398 slots of the three classes are classified; one not in a group raises.
  • The orchestrator maps inverter after capacitor and classifies solar and battery with it.
  • glm_schema.registry_unit spells pu and unit as dimensionless and sf/W/sf as ft**2/W/ft**2. Pint read pu as a picounified atomic mass and unit as a micronit, and did not know sf.
  • Found at build (amendments):
  • InverterCapabilities is not written. It is an Identity, so cim-tables keys it by identifier. cim-tables does not index an Identity row, so InverterInfo.InverterCapabilities cannot reference it (CIM-Tables/docs/CIMTBL_DESIGN.md:141). The row comment names the flag (capability: ...) until cim-tables can (plan section 7).
  • phaseCount is dropped from the inverter datasheet. It is an enum (singlePhase, threePhase, other) that only repeats the connection's phases.
  • GridLAB-D's cap is on the total: |S| ≤ p_max = phases out × rated_power (inverter.cpp:3798), not per phase. So IEEE 13's inv_bat_school gives -99,999.999 W, not -100 kW. Its rated_power is written 33333.333 per phase, and its P_Out of 100 kW is above that. The row comment says the set point was limited.
  • The defaults are by path: PV defaults inverter_efficiency and power_factor; a battery defaults P_Out, Q_Out and soc_reserve.
  • A climate object is found by the reader's not-read count: the schema has no climate class.
  • A battery's maxP is its own rated_power, its nameplate as written. GridLAB-D's internal model limits the battery at the inverter's rated_battery_power, phases out × rated_power / inverter_efficiency (battery.cpp:2206, inverter.cpp:1415). That limit is untranscribed.
  • Tests:
  • tests/test_cimtbl_inverter.py, with the atom tests/atoms/inverter/inverter.glm. The atom has eight inverters: 3-phase, 1-phase and split-phase PV (the last capped), plus five batteries:
    • CONSTANT_PQ discharging;
    • the CONSTANT_PF Java defect;
    • full;
    • at its reserve;
    • OFFLINE.
  • Goldens for the atom and IEEE13_cdpsm (inverter.cimtbl).
  • Every deck's inverters read back through the core DER getters (get_der_output, get_inverter_rating, get_inverter_unit, get_photovoltaic_unit, get_battery_unit) against GridLAB-D's formulas written out again in the test.
  • IEEE13_cdpsm is checked against the DSS golden's battery dispatch and against GridLAB-D's PV output.
  • Results:
  • 461 GLM tests pass with --roundtrip over every deck, and the core and DSS suites pass (983). The leak gate is clean.
  • 27 decks bind; the same two deck defects stop the other two. IEEE13_cdpsm is the only binding deck with DER.
  • IEEE13_cdpsm:
    • PV: -298.25 kW at the school and -4.97 kW at the house (GridLAB-D's static weather).
    • Batteries: -100 kW (the school's 0.001 W under GridLAB-D's cap), +5 kW and +1 kW, as the DSS golden.
    • The house inverters are s1s2 D at 240 V.

Field tables (generated: fields_table(cls, records), the read slots only; samples from the atom and IEEE13_cdpsm)

inverter (the slots the mapper reads; the untranscribed groups follow)

Inverter field type samples kind target
name Union[str, InverterName] inv_b3, inv_bfull, inv_boff derived PowerElectronicsConnection.name; mRID pv_/storage_ + name by its unit (S4b-6)
parent Optional[str] m3, m4, tm1 structural node: the parent's root bus (GLM-4)
inverter_type Optional[str] FOUR_QUADRANT structural FOUR_QUADRANT; any other raises, unset is GridLAB-D's PWM (inverter.cpp:1350) (S4b-1)
four_quadrant_control_mode Optional[str] CONSTANT_PQ, CONSTANT_PF structural CONSTANT_PF on a solar, CONSTANT_PQ on a battery, which also reads CONSTANT_PF as the Java defect (S4b-2); others raise; the capability flag goes in the row comment
pf_reg Optional[str] structural EXCLUDED (default); power-factor regulation raises when set: no deck sets it, so a mapping waits for one
generator_status Optional[str] OFFLINE, ONLINE derived normallyInService: ONLINE (default) true; OFFLINE false, output 0 (inverter.cpp:2561)
P_Out Optional[float] 50000.0, -20000.0, 30000.0 derived battery: the CONSTANT_PQ set point (S4b-2); PV: an output GridLAB-D overwrites (inverter.cpp:3879), listed in the row comment
Q_Out Optional[float] derived CONSTANT_PQ: q = 0 when unset or 0; any other value raises (S4b-3)
rated_power Optional[float] 33333.333, 15000.0, 20000.0 derived ratedS = rated_power x phases out (3, 2, 1; S is 1, inverter.cpp:1318); maxQ = -minQ = apparentPowerMaximum = ratedS; unset or 0 raises (GridLAB-D's silent 25 kVA, :1409)
inverter_efficiency Optional[float] 0.95, 1.0, 0.975 derived PV: AC = DC x inverter_efficiency (inverter.cpp:3290); unset, 0 or negative is 0.9 (:1398); CIM has no inverter efficiency
soc_reserve Optional[float] 0.2, 0.25 derived BatteryUnit.minimumE = soc_reserve x battery_capacity; the battery does not discharge at or below it; default 0
power_factor Optional[float] -1.0, 1.0 derived CONSTANT_PF: q = 0 when
phases Optional[str] ABCN, ACN, AS structural A, B, C wye to neutral (3 phases: blank); S: s1s2 D across the legs at 240 V (S4b-4). GridLAB-D has no D keyword on an inverter
use_multipoint_efficiency Union[bool, Bool, NoneType] False structural FALSE (default); TRUE raises (no deck)
max_charge_rate Optional[float] 80000.0, 100000.0, 5000.0 copied StorageInverterInfo.chargeRateActiveMax (W); nameplate; GridLAB-D reads it only in load following
  • untranscribed, object header: 7 slots (groupid ... flags)
  • untranscribed, read only by the non-four-quadrant types (inverter.cpp:1337), which raise: 1 slots (generator_mode)
  • untranscribed, deltamode, VSI, droop and IEEE 1547 trip settings: dynamics, not the steady-state snapshot: 119 slots (inverter_convergence_criterion ... first_iter_counter)
  • untranscribed, solver state or output: 47 slots (V_In ... prev_value_IGenerated_C)
  • untranscribed, read only by the multipoint efficiency model, which raises: 8 slots (inverter_manufacturer ... c_3)
  • untranscribed, read only by load following and the group modes, which raise: 18 slots (sense_object ... lf_dispatch_change_allowed)
  • untranscribed, read only by power-factor regulation (pf_reg), which raises: 10 slots (pf_reg_activate ... pf_reg_next_update_time)
  • untranscribed, read only by the volt-var, volt-watt and frequency-power modes, which raise: 30 slots (disable_volt_var_if_no_input_power ... pc_vw_limited)
  • untranscribed, read only by the volt-var and volt-watt modes (inverter.cpp:318), which raise; ratedU is the bus's line-to-line voltage (S4b-5): 1 slots (V_base)

solar (the slots the mapper reads; the untranscribed groups follow)

Solar field type samples kind target
name Union[str, SolarName] pv1, pv3, pvs derived PhotoVoltaicUnit.name; mRID _unit
parent Optional[str] inv_pv1, inv_pv3, inv_pvs structural its inverter; another parent raises
panel_type Optional[str] MULTI_CRYSTAL_SILICON, SINGLE_CRYSTAL_SILICON derived the defaults of efficiency and Pmax_temp_coeff (solar.cpp:559); default SINGLE_CRYSTAL_SILICON
SOLAR_POWER_MODEL Optional[str] structural DEFAULT (BASEEFFICIENT); others raise
NOCT Optional[float] derived the module temperature (S4b-2); default 118.4 degF
Rated_Insolation Optional[float] derived SolarPanelInfo.referenceIrradiation; the irradiance = Rated_Insolation x shading_factor (solar.cpp:1170); default 92.902 W/sf = 1000 W/m^2
Pmax_temp_coeff Optional[float] derived per degF, the DC output's temperature factor; default by panel_type
efficiency Optional[float] 0.2 copied SolarPanelInfo.efficiency (percent); default by panel_type
area Optional[float] structural raises when set: no deck sets it, so a mapping waits for one (with efficiency it can override rated_power, solar.cpp:624)
soiling Optional[float] 1.0 derived a factor of the DC output; default 0.95; outside 0..1 raises
derating Optional[float] 1.0 derived a factor of the DC output; default 0.95; outside 0..1 raises
rated_power Optional[float] 8000.0, 250000.0, 6000.0 derived maxP (W via pint), minP 0, and the DC output (S4b-2); unset raises (GridLAB-D derives it from area and insolation, solar.cpp:606)
weather Optional[str] structural unset, with no climate object in the model; a climate raises (S4b-2)
shading_factor Optional[float] 0.8 derived SolarArrayInfo.shadingFactor (percent) and the irradiance; default 1
tilt_angle Optional[float] 30.0 copied SolarArrayInfo.tiltAngle (deg); default 45
orientation_azimuth Optional[float] 200.0 copied SolarArrayInfo.orientationAzimuth (deg); default 180
orientation Optional[str] structural DEFAULT; others raise (FIXED_AXIS needs a climate, solar.cpp:325)
  • untranscribed, object header: 7 slots (groupid ... flags)
  • untranscribed, read only by the PV_CURVE and FLATPLATE models, which raise: 16 slots (pvc_Pmax_calc_simp_mode ... T_coeff)
  • untranscribed, read only with a climate object, which raises: 2 slots (SOLAR_TILT_MODEL, latitude_angle_fix)
  • untranscribed, solver state or output: 15 slots (Tmodule ... last_DC_power)
  • untranscribed, with no climate GridLAB-D uses 59 degF and still air (solar.cpp:321): 2 slots (wind_speed, ambient_temperature)
  • untranscribed, DC voltage and current: CIM has no DC array model: 5 slots (Rinternal, Voc_temp_coeff, V_Max, Voc_Max, Voc)

battery (the slots the mapper reads; the untranscribed groups follow)

Battery field type samples kind target
name Union[str, BatteryName] b3, bfull, boff derived BatteryUnit.name; mRID _unit
parent Optional[str] inv_b3, inv_bfull, inv_boff structural its inverter (GridLAB-D requires one, battery.cpp:657); another raises
rfb_size Optional[str] structural raises when set: no deck sets it, so a mapping waits for one (it overrides the battery's ratings, battery.cpp:661)
use_internal_battery_model Union[bool, Bool, NoneType] True structural true; false (the legacy model) raises
battery_type Optional[str] LI_ION, LEAD_ACID derived BatteryInfo.batteryType: LI_ION lithiumIon, LEAD_ACID leadAcid; others blank
nominal_voltage Optional[float] 48.0 derived BatteryInfo.numberOfCells = floor(nominal_voltage / 4.1) on LI_ION (battery.cpp:720); default 115 V
rated_power Optional[float] 100.0, 30000.0, 60000.0 derived maxP = rated_power, minP = -rated_power (the generation sign)
battery_capacity Optional[float] 200.0, 50000.0, 100000.0 derived ratedE and BatteryInfo.ratedCapacity (Wh via pint); unset raises
round_trip_efficiency Optional[float] 0.86 derived chargingEfficiency = dischargingEfficiency = sqrt of it, percent (battery.cpp:2220); default 0.8
state_of_charge Optional[float] 0.6, 1.0, 0.5 derived storedE = state_of_charge x battery_capacity; unset raises
  • untranscribed, object header: 7 slots (groupid ... flags)
  • untranscribed, read only by the legacy battery model (use_internal_battery_model false), which raises: 31 slots (generator_mode ... parasitic_power_draw)
  • untranscribed, solver state or output: 29 slots (V_Out ... climate_object_found)
  • untranscribed, set from the inverter's soc_reserve (battery.cpp:727): 1 slots (reserve_state_of_charge)

S5 maps nothing new: no deck holds a latitude or longitude, so there is no coordinates part (the DSS S5's buscoords.cimtbl has no GLM source). It turns the eight per-slice deck sweeps into one, closes D6 with a complete IEEE13_cdpsm golden directory, adds the cross-format IEEE 13 GLM vs DSS check, and records G7.

The deck sweep (S5-1)

Today each of the eight slice modules (bus, catalog, line, transformer, regulator, load, capacitor, inverter) has its own test_every_* over ALL_DECKS, with the same stop boilerplate, so every deck is read and bound eight times (the GLM suite with --roundtrip takes 4 min 30 s). tests/test_cimtbl_sweep.py reads and binds each deck once and runs every slice's GridLAB-D check on that network:

  • assert_gridlabd_ohms (S3b), assert_gridlabd_regulation (S3c), assert_gridlabd_loads and assert_gridlabd_capacitors (S4a), assert_gridlabd_der (S4b), and the bus, catalog and line counts the slice sweeps assert today, each moved to a named assert_* helper in its slice module;
  • a deck in BIND_STOPS must stop with its listed error, an unlisted stop fails, and a listed stop that binds fails, so the table stays true. Expected: 27 of 29 bind; IEEE123_transactive (Object battery) and IEEE13_houses (its 634 center taps rated 2401 V on a 480 V bus) stop, as today.

The slice modules keep their atoms, goldens and fail-fast tests. test_every_deck_walks stays in test_topology_walk.py (it stops at the walk, not the bind).

The IEEE13_cdpsm golden directory (S5-2, D6)

The committed directory does not bind on its own: its master imports zip_fractions.cimtbl (the core's shared ZIP rows), which no slice committed. S5 adds it, so the directory holds 16 files, and one test checks the whole directory: the written file set equals the golden set (no file missing or extra), every file matches its golden, and the golden directory binds with cimtables.load_model. It replaces the nine per-slice IEEE13_cdpsm golden tests (DRY: one place to regenerate, CIMHUB_UPDATE_GOLDENS=1).

Cross-format: IEEE 13 GLM vs DSS (S5-3)

IEEE13_cdpsm.glm is the Java CIMHub export of the model the DSS importer's IEEE13_CDPSM golden holds. The test binds the two committed golden directories with cimhub_core and cimtables only, matches equipment by its terminal buses (the bus names agree), and compares through the core getters in SI. It imports neither spoke and needs no engine, so it lives at the workspace root, tests/cross_format/test_ieee13_glm_vs_dss.py, as the cross-format location rule says (a test that touches two spokes' artifacts belongs to neither). The root needs a tests/conftest.py (the cim_scope fixture) and scripts/test-all.sh runs it as one more process.

Probe on 2026-11-10 (both golden directories, the GLM one completed by S5-2):

class compared result
bus voltages BaseVoltage of every line, load and capacitor equal
lines (11) phases, length, the phase R and X matrices in ohms (length x per-length, conductor order sorted) equal to 4 places
switches (5) class (LoadBreakSwitch, Fuse, Recloser), phases, normal state equal
loads p, q per bus and phase (DSS has 16 consumers, one per DSS Load; GLM 10) equal
capacitors (2) nomQ at nomU per bus; neither has a control equal
regulator taps (3) low, high, neutral, step (8, 10, 11), increment 0.625 % equal
DER (5) S4b's cross-solver note batteries and ratings equal; PV and the house's connection follow GridLAB-D
transformers ratings, voltages, connections, impedance, core admittance equal on xf1 and the house center tap

Expected differences (asserted as differences, so a change on either side shows): 1. Source: DSS 30 deg with the deck's short-circuit impedance; GLM 0 deg with the stiff default (S1-3). 2. Substation transformer: DSS has three windings (a 13.2 kV tertiary on its internal bus 650z); the Java export wrote two, so GLM has no 650z. 3. Transformer impedance: closed. The core getter now reads a TankConfiguration's %Z (with the Hopkinson center tap), so GLM's xf1 and house center tap equal the DSS mesh, and the substation's two windings equal DSS's first two; the impedance is compared under transformers. 4. Regulator controls: the Java export wrote Control MANUAL with band_center commented out, so GLM's controls are disabled with no target; DSS's regulate at 2440 V, 40 V band, delay 15 s. GLM's line drop is 1/5 of DSS's (0.01714 + j0.05143 vs 0.0857 + j0.2571 ohm): the Java export wrote DSS's CT ratio, 3500 = 700 A / 0.2 A, where GridLAB-D's compensator divides the current by current_transducer_ratio as a 1 A secondary (regulator.cpp:1330, S3c-4). It is not active under MANUAL. See S5-4 and S5-5. Found at build: neutralU is 2400 V in DSS (its 2.4 kV winding) and 2401.78 V in GLM (the coil: the 4.16 kV bus over sqrt 3, S3c); the tap positions, range and increment are equal. 5. DER: the S4b cross-solver note (PV output; s1s2 D at 240 V vs the DSS shape's Y at 208 V).

G7 (S5-6)

Measured 2026-11-10 on orig_R3-12.47-3, the largest deck:

deck read map bind
orig_R3-12.47-3 3.0 s 0.5 s 4.8 s: 26,622 rows / 52,118 objects, about 5,500 rows/s
IEEE13_cdpsm <0.1 s <0.1 s 0.1 s: 224 rows / 340 objects

That is the DSS importer's rate (about 7,900 rows/s on IEEE9500 including coordinates), so G7 needs no work; the sweep test records no timing (it would be flaky).

# question recommendation
S5-1 Per-slice deck sweeps One sweep test, one bind per deck, every slice's check on it; the eight test_every_* go
S5-2 The IEEE13_cdpsm golden (D6) Add zip_fractions.cimtbl; one directory test (file set, each file, the directory binds) replaces the nine per-slice IEEE13 golden tests
S5-3 Where the cross-format test lives Root tests/cross_format/, comparing the two committed golden directories through the core getters (no spoke import, no engine); expected differences asserted, not skipped
S5-4 A disabled TapChangerControl with no target (GLM MANUAL) The core get_tap_changer_control raises targetValue is unset, so neither the cross-format test nor an exporter can read GLM's 3 IEEE 13 regulators (nor any MANUAL unit without a band). Recommended: core returns target None when the control is enabled false (a plan section 7 core row; the cross-format test compares the taps until then). The alternative, the importer writing GridLAB-D's default band_center 0, would write a value GridLAB-D never reads
S5-5 The Java export's CT ratio Keep GridLAB-D's reading (the engine's 1/5 compensation, as the deck would run), list it as an expected difference and a Java export defect, as S4b's battery. The alternative, reading it as DSS's CT primary (x 0.2), would follow the Java exporter's intent the way S4b's battery does; but here the mode is MANUAL, so nothing runs on it
S5-6 G7 Recorded above; closed with no work

Built (2026-11-16)

On rc_1 ddc6227 (the worktree fast-forwarded the same day; no incoming commit touched cimhub_gridlabd).

  • Sweep (S5-1): tests/test_cimtbl_sweep.py, test_every_deck_binds_as_gridlabd_runs_it, one read and one bind per deck. The checks the slice sweeps made inline are now named helpers in their modules (assert_buses, assert_catalogs, assert_lines_and_switches, assert_transformers); the others were already (assert_gridlabd_regulation, _loads, _capacitors, _der). The eight test_every_* sweeps are gone, and so is S4b's test_ieee13_cdpsm_against_the_dss_golden, whose values the cross-format test now asserts against the DSS golden itself.
  • D6 (S5-2): zip_fractions.cimtbl added, so goldens/IEEE13_cdpsm/ has 16 files. test_ieee13_cdpsm_golden_directory writes the documents, matches every file to its golden, checks that the two file sets are the same, and binds the golden directory on its own (cimtables.load_model). It replaces the nine per-slice IEEE13_cdpsm golden tests, the master's included; CIMHUB_UPDATE_GOLDENS=1 rewrites the whole directory.
  • Cross-format test (S5-3): tests/cross_format/test_ieee13_glm_vs_dss.py (13 tests) plus a root tests/conftest.py; scripts/test-all.sh runs it as its own process (scripts/test-all.sh cross_format, and CI's no-argument run). It imports cimhub_core and the cim-graph stack only. Eight tests check what is equal (buses, base voltages, lines, switches, loads, capacitors, regulator taps, transformer ratings and core). Five assert the expected differences 1-5, so either side changing shows. Test 3 asserts that the core getter reads no GLM impedance yet: when the template %Z row lands it fails, and the impedance joins test_transformers.
  • Amended at build:
  • Line matrices: R, X and B in ohms and siemens are equal to the getter's float precision: the largest relative difference is 0.
  • Loads: compared at a relative 1e-5. Bus 646's constant-impedance delta load is 66,000.09 W per phase in GLM against DSS's 66,000 W, which is the Java export's 6-digit rounding.
  • Regulators: neutralU differs (expected difference 4).
  • S5-4: plan section 7 core row (a disabled control may have no target). S5-5: listed as expected difference 4 and a Java export defect; the mapping keeps GridLAB-D's reading.
  • Results: the GLM suite with --roundtrip (29 decks): 249 passed in 51 s, down from 461 in 4 min 30 s. That is 461 - 232 sweep runs - 10 IEEE 13 tests + 29 sweep runs + 1 directory test. Core: 449 passed. Cross-format: 13 passed. Leak gate and lint are clean.

S6: a utility's Milsoft WindMil decks (by the user's direction 2026-11-16; built, approved 2026-11-16)

The user's direction: test the converter on a utility's 22 GridLAB-D feeders exported by Milsoft's "WindMil to GridLabD Export" (2022), and edit the exports so that GridLAB-D loads them. They are kept out of git (the utility's data). The sweep binds every deck in CIMHUB_GLM_UTILITY_DECKS (S6-8); the decks' repair log, a patch against the originals and the scripts are kept with the data, not here.

The exports are flat: node, load (constant power), overhead_line/underground_line on z-matrix line_configurations (no geometry), transformer on resistance/reactance configurations, switch, recloser (WindMil writes fuses as reclosers), capacitor, regulator. About 60,000 nodes, 37,000 lines, 17,000 transformers.

What GridLAB-D rejects (deck repairs, by the user's leave)

Each repair answers a GridLAB-D error, not the converter's, so the converter is not taught the defects: - lower-case dump mode rect (convert.cpp:427 matches keywords case-sensitively) and a Windows dump path; - no swing bus: the head node is bustype PQ; under FBS the first node in becomes the swing (node.cpp:1602), so the repair writes the SWING FBS gives it; - dangling references: a span from <capacitor>_n (WindMil's in-line capacitor), a sense_node with its leading _ lost, a second consumer on X-1_n, and sense_node NULL _n on every REMOTE_NODE regulator (the remote point is lost; it becomes the regulator's own output, regulator.cpp:154 throws without one); - phasing errors: 3-phase sections fed through 1-phase spans, which the exporter joins with fake_g_*_n nodes (children on phases their parent lacks, node.cpp:1079; links on phases their ends lack, link.cpp:664). The user's choice: widen the narrow path to the phases below it, each span on the same conductor's wider Milsoft configuration (copied from a sibling deck when the deck lacks it; WindMil writes its catalog in single precision, so copies agree to 1e-6). A customer on 2 or 3 phases behind one 1-phase service can is likely a wye-delta bank, which GridLAB-D does not model; the user's call: parallel cans, the transformer on the customer's phases with Milsoft's own WYE_WYE-<kVA>x<n> configuration (n x the can's kVA and per unit, so every phase has the can's ohms); - open ties between laterals on different phases (link.cpp:649 throws whatever the status): kept, the user's call, as CIM holds them (S6-9). So 10 decks do not load in GridLAB-D as they stand; without the 21 open switches they do, with the same solution; - one nameplate: 12470 V primaries on 14.4 kV (phase-to-neutral) buses; GridLAB-D runs them 15 % high and the walk rejects them. The user's choice: primary_voltage 14400.

What the converter now maps (S6-1 to S6-7)

S6 Subject Built
S6-1 Wye rating basis (amends S3b-3; approved: ratedU line to line, baseU the coil, line to neutral on a wye) GridLAB-D uses a wye's voltages only as nt = V1 / V2 and the base V2² / S (transformer.cpp:265), so either reading solves the same; the deck says which. topology.coil_rated: the written primary_voltage is its from bus's nominal_voltage (phase to neutral; the Milsoft exports) or that × √3 (line to line; the Java exports, S3b-3), within the walk's nameplate tolerance; anything else raises. A coil-rated wye: baseU as written, ratedU on its bus's system (line_voltage), k = S_coil / S_total (S3b-4's ohms kept); in the walk one phase-to-neutral coil per side on one conductor (a 7200/120 V service is a single-phase system), else polyphase at × √3. An unused configuration keeps S3b-3, noted. Confirmed by the user 2026-11-16 after an independent hand translation of one deck (the cimtbl-translate skill) wrote the can as connectionKind I, phases A, ratedU = the coil: the converter's tank template, Yn on AN, ratedU line to line and baseU the coil stays (as the DSS import). That translation agreed on every line impedance, the source voltage and the can's series ohms
S6-2 SINGLE_PHASE One case with WYE_WYE in transformer.cpp:282: mapped as it (Y/Y, grounded)
S6-3 One template per phase count A one-tank wye with no phase ratings depends only on how many phases it is wired on, so one configuration may serve A, B and C (the Milsoft decks share one per kVA)
S6-4 Matrix lines (amends S3a-3) N on a matrix line is dropped (line.cpp:226 fills the Kron-reduced A, B, C only); a written 0 z_ii is no phase, a nonzero term on such a phase raises, all-zero raises. The user's call 2026-11-16: the matrix is written as given, 3x3 and already reduced: GridLAB-D's line_configuration has no neutral terms (line_configuration.cpp:40-46), so there is no 4x4 to write, and an exporter must not reduce it again (a 4x4 with the neutral, where a source gives one, is left for the exporter to reduce, e.g. OpenDSS reduce=y). Geometry lines keep their neutral position
S6-5 Link phases A link's phases (N, D aside) must be on both its end objects, as link::init throws (link.cpp:649, :664; a center tap's S on its to end only): the walk raises, S6-9 aside
S6-6 REMOTE_NODE (amends S3c-6; approved) Sensing the regulator's own output (its to bus) GridLAB-D reads the voltages OUTPUT_VOLTAGE reads (regulator.cpp:1376-1420): mapped as it, the records identical; a remote sense node still raises. A sense_node on another Control GridLAB-D does not read (:150): listed on the row
S6-7 Regulator phases PT_phase/CT_phase on INDIVIDUAL GridLAB-D does not read (:1328, :1378): listed on the row, no longer raise. A BANK on its one PT_phase is one unit on it (named as a gang, xf_<name>)
S6-9 Open ties across phases (the user's call) An open switching device whose switched letters are on its from end and whose to end has as many other letters (an -A switch from an A lateral to a B one) is phaseSide1 = its letters, phaseSide2 = its to end's, paired in ABC order (cim-tables' phaseSide1/phaseSide2 columns; each Terminal on its side's phases), with a row note. Closed, or overlapping letters, still raise (S6-5). GridLAB-D cannot load it: the converter holds what the source system has, not only what GridLAB-D runs. The sweep checks every switch's sides against its GLM ends
S6-8 Utility decks in the sweep test_every_utility_deck_binds_as_gridlabd_runs_it: every non-empty *.glm in CIMHUB_GLM_UTILITY_DECKS binds and passes every slice check (--roundtrip); no stop table, so no names in git
S6-10 One-phase services (the user's, 2026-11-16) A coil-rated SINGLE_PHASE/WYE_WYE on one phase and N (a Milsoft service) is split-phase by its secondary_voltage (within the walk's 10 % nameplate tolerance, as coil_rated: a 110 V can is a leg), as a 208 V secondary of three coils is ABC line to line: 120 V is the s1 leg to N (end 2 s1N, kind I on the instance, one split-phase half as a center tap's s1, a can whose X1 lands on s1 (S3b-13); the coil 120 V, ratedU 240); 240 V is a center tap (end 2 s1s2N, kind I, the center-tap template of lugs H1 H2 X1 X3 X2 with 120 V halves at S/2 on the can's S, and GridLAB-D's R + jX on 240²/S as the full winding, so a 240 V load sees the same R + jX and each leg reads 120 V to ground; written as one s1-s2 coil its legs floated). Either bus is a 240 V split-phase system (bv_240v), and a load's one phase there becomes the s1 leg or the s1-s2 240 V consumer. Only loads may sit on a service bus: a link, capacitor or inverter raises. JOHNSON CREEK: 430 120 V and 278 240 V services; before, 707 nodes read 1.73 pu on a 120 V BaseVoltage taken as line to line. Kind I and the tolerance are merged from glm-repair's build of the same rule (that user's call)
S6-11 Other one-phase secondaries (the user's, 2026-11-19, clallum-models request 12) A coil-rated SINGLE_PHASE/WYE_WYE on one phase and N whose secondary_voltage is not a 120/240 V service (S6-10) is one phase of a wye, as its primary is: the walk sees a polyphase coil of the written voltage x sqrt 3, so the bus is a 3-phase system and its BaseVoltage is line to line (277 V -> bv_480v, 2400 V -> bv_4p16kv, as a 7200 V primary is on 12.47 kV). Before, it was a single-phase system on the coil voltage (bv_277v), which a line-to-line reading put at 1.73 pu. The physics is unchanged: the template's baseU is still the coil and its ratedU the line voltage. A 120/240 V service keeps its 240 V split-phase base. GLM only: the walk's own rule 4 (cimtopology) still makes a step-down single-phase coil single-phase for the other importers

Built (2026-11-16)

  • Results: all 22 utility decks bind and pass every slice check, assert_gridlabd_ohms included (17,000 transformers at GridLAB-D's zt); the largest reads in 1.2 s and binds in 6.1 s. The 29 Powergrid-Models decks are unchanged (27 bind, the 2 stops as before). The GLM suite with --roundtrip: 257 passed; with the utility decks the sweep is 52 passed in 105 s. After S6-9 and the parallel cans: 281 passed with both deck sets.
  • Tests: the S3a/S3b/S3c fail-fast tests of the amended rules now test the mappings (coil-rated wyes against GridLAB-D's ohms, a wye off its bus raises, a matrix line's N, a 0 diagonal, REMOTE_NODE on its own output against OUTPUT_VOLTAGE, a remote one raises, the two row notes, a one-phase BANK, an open tie across phases and a closed one raising); the walk has the coil-rated coils and the link-phase check. A triplex line and a regulator on phases their ends lack now stop at S6-5 first.

S7: series reactors (by the user's "go for the next phase", 2026-11-21; built the same day)

No GLM deck has a series_reactor, so GLM-14 left it unmapped. The exporter now writes one for a SeriesCompensator (EXPORT_MAPPING.md X28: IEEE 8500's substation reactor, the DSS deck's source impedance), so the importer reads it back, or a DSS-origin deck would lose its feeder head on the way back.

Mapper: importer/cimtbl/series_reactor.py map_series_reactors; shape series_compensator. Test: tests/test_cimtbl_series_reactor.py; atom tests/atoms/series_reactor/series_reactor.glm (on the S3a line atom).

# GridLAB-D series_reactor -> SeriesCompensator.
# r0 = r, x0 = x: GridLAB-D's reactor has no coupling between phases
Table SeriesCompensator: mRID, name, node1, node2, r (ohm), x (ohm), r0 (ohm), x0 (ohm), BaseVoltage, EquipmentContainer=fdr_atom
    rx_hsb, hsb, n2,  rb1, 0.0, 14.798307, 0.0, 14.798307, bv_4p16kv
    rx_r1,  r1,  rb1, rb2, 0.5, 2.0,       0.5, 2.0,       bv_4p16kv

# SeriesCompensator has no per-phase class: a reactor on fewer than three phases gives its Terminals their phases here
Update Table Terminal: mRID, phases
    rx_r1_T1, B
    rx_r1_T2, B

Decisions for S7

# question decision
S7-1 Identity rx_<name>, source case (the DSS importer's prefix)
S7-2 Impedance GridLAB-D's reactor is one impedance per phase with no coupling (series_reactor.cpp:105), CIM's SeriesCompensator one r + jx for every phase: the phases' phase_X_impedance must be equal, r and x copied from it, r0 = r and x0 = x (the DSS importer's rule)
S7-3 Phases A, B, C, N dropped; three phases leave the Terminals' phases unset (the shape's balanced form), fewer give them by an Update
S7-4 Ratings the link's own, on its own OperationalLimitSet (S3a-4)

Fail fast (S7)

condition why
phases whose phase_X_impedance differ CIM's SeriesCompensator has one impedance
a phase's phase_X_impedance unset GridLAB-D's 0 is a switch stand-in under NR (1e4 + 1e4j S, series_reactor.cpp:122), not a reactor
phase_X_resistance or phase_X_reactance set GridLAB-D's aliases of the impedance's parts; no deck sets one
status OPEN the walk raises (S0): a reactor is not a switch

series_reactor

SeriesReactor field type samples kind target
name Union[str, SeriesReactorName] hsb, r1 copied SeriesCompensator.name; mRID = rx_ + name
phases Optional[str] ABCN, BN structural the reactor's A, B, C, N dropped; fewer than three: its Terminals' phases
nominal_voltage Optional[float] untranscribed the walk gives the BaseVoltage (GLM-1)
status Optional[str] structural unset or CLOSED; OPEN raises in the walk (a reactor is not a switch)
from_node Optional[str] n2, rb1 structural node1: the root bus of the object it names (GLM-4)
to Optional[str] rb1, rb2 structural node2: the root bus of the object it names (GLM-4)
pdispatch Optional[float] untranscribed dispatch control; no network-profile home
pdispatch_offset Optional[float] untranscribed dispatch control; no network-profile home
set_pdispatch Union[bool, Bool, NoneType] untranscribed dispatch control; no network-profile home
mean_repair_time Optional[float] untranscribed reliability data
continuous_rating_A Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_B Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
continuous_rating_C Optional[float] 400.0 structural the normal CurrentLimit of the equipment's own OperationalLimitSet _limits (S3a-4, S3a-5); the set phases must agree
emergency_rating_A Optional[float] 400.0 structural the emergency CurrentLimit of that set
emergency_rating_B Optional[float] 400.0 structural the emergency CurrentLimit of that set
emergency_rating_C Optional[float] 400.0 structural the emergency CurrentLimit of that set
phase_A_impedance Union[dict, Complex, NoneType] Complex({'real': 0.0, 'imag': 14.7983... copied SeriesCompensator.r ({unit}), SeriesCompensator.x ({unit}), SeriesCompensator.r0 ({unit}), SeriesCompensator.x0 ({unit}); real part r, imaginary x; r0 = r, x0 = x (no coupling); every phase's equal, unset raises
phase_A_resistance Optional[float] structural GridLAB-D's alias of the impedance's real or imaginary part; set raises (no deck sets one; the impedance is mapped)
phase_A_reactance Optional[float] structural GridLAB-D's alias of the impedance's real or imaginary part; set raises (no deck sets one; the impedance is mapped)
phase_B_impedance Union[dict, Complex, NoneType] Complex({'real': 0.0, 'imag': 14.7983..., Complex({'real': 0.5, 'imag': 2.0}) copied SeriesCompensator.r ({unit}), SeriesCompensator.x ({unit}), SeriesCompensator.r0 ({unit}), SeriesCompensator.x0 ({unit}); real part r, imaginary x; r0 = r, x0 = x (no coupling); every phase's equal, unset raises
phase_B_resistance Optional[float] structural GridLAB-D's alias of the impedance's real or imaginary part; set raises (no deck sets one; the impedance is mapped)
phase_B_reactance Optional[float] structural GridLAB-D's alias of the impedance's real or imaginary part; set raises (no deck sets one; the impedance is mapped)
phase_C_impedance Union[dict, Complex, NoneType] Complex({'real': 0.0, 'imag': 14.7983... copied SeriesCompensator.r ({unit}), SeriesCompensator.x ({unit}), SeriesCompensator.r0 ({unit}), SeriesCompensator.x0 ({unit}); real part r, imaginary x; r0 = r, x0 = x (no coupling); every phase's equal, unset raises
phase_C_resistance Optional[float] structural GridLAB-D's alias of the impedance's real or imaginary part; set raises (no deck sets one; the impedance is mapped)
phase_C_reactance Optional[float] structural GridLAB-D's alias of the impedance's real or imaginary part; set raises (no deck sets one; the impedance is mapped)

S8: load players (by the user's direction, 2026-11-21: ConformLoad groups, points in a Parquet sidecar)

GLM_REWRITE_PLAN.md §8.9 (S4a-2's TODO). A load base <player>.value*K scales K by the player's value over time, through the GridAPPS-D run file's pattern: module tape;, class player { double value; }, then object player { name ieeezipload; file zipload_schedule.player; }. One player drives many loads, as a DSS LoadShape does, so it is the classic shared schedule: a ConformLoadGroup whose ConformLoadSchedule gives the curve as a multiplier, its loads ConformLoads (shape load_schedule). Not nc_schedule's EnergyConnectionSchedule: one actual-value schedule per device (GDM's T1), which would copy one shape onto every load.

Mappers: importer/cimtbl/player.py map_players (the groups and schedules; player_points, the points) and load.py (a scheduled record's consumers are ConformLoad rows with a LoadGroup). The reader reads the class block and each player's file (GlmModel.classes, GlmModel.tapes). Tests: tests/test_cimtbl_player.py; atom tests/atoms/player/player.glm (on the S3a line atom, the first four rows of GridAPPS-D's zipload schedule).

# one group per player: the loads whose base is <player>.value*K
Table ConformLoadGroup: mRID, name
    lg_zipload, zipload

# value1: the player's value, a multiplier of each load's p and q; the points are RegularTimePoints in the Parquet sidecar
Table ConformLoadSchedule: mRID, name, startTime, timeStep (s), value1Unit, ConformLoadGroup
    ls_zipload, zipload, 2009-07-21T00:00:00-04:00, 60.0, none, lg_zipload

# a base <player>.value*K: p, q from K; the player's group (S8-1)
Table ConformLoad: mRID, name, node, phases, ..., LoadResponse, BaseVoltage, LoadGroup, EquipmentContainer=fdr_atom
    ld_ld_play, ld_play, n5, A, Y, true, 16999.99323672, 10000.005731892072, 1, zip_constant_i, bv_4p16kv, lg_zipload

The points are not in the artifact: GlmImporter(time_points={}) (or glm_to_cim(..., time_points=...)) adds a RegularTimePoint table (cimhub_core.time_points: the schedule's uri, sequenceNumber from 0, value1) to the caller's dict after binding, as GDM's importer does; write_time_points puts it beside the XML. Without the dict the points are dropped with one warning.

Decisions for S8

# question decision
S8-1 Shape one player → ConformLoadGroup lg_<player> + ConformLoadSchedule ls_<player>. A load whose bases name it is a ConformLoad of that group, its p, q K's split as before (S4a-2). A ConformLoad has one group and scales every phase: two players on one record, or a phase with power but no player beside one with it, raise
S8-2 Values value1 = the player's value, value1Unit none: a multiplier of p and q together (GLM scales the base)
S8-3 Times startTime = the first row's time, its zone an offset (2009-07-21 00:00:00 EDT → 2009-07-21T00:00:00-04:00; US zones and UTC/GMT, player.ZONES, others raise); timeStep = the one step between rows (+1m → 60 s; +N[smhd] after the row before, or absolute), steps that differ raise; a one-row tape has no step
S8-4 Points RegularTimePoint rows in the Parquet sidecar, never graph objects (GDM's T6), numbered from 0 (CIM: a point's time is startTime + sequenceNumber × timeStep)
S8-5 A player the deck does not define a group with no schedule and one warning, so the name survives (the Java exports: their run file defines ieeezipload). The exporter writes such loads static (X29)
S8-6 Players read only the run-file pattern: no parent, property, filetype, mode; loop unset or 0; the deck's class player { double value; }

Fail fast (S8)

condition why
a player with parent, property, filetype or mode only a player read as <name>.value is mapped (S8-6)
loop above 0 a schedule has one pass
no file, a missing file, a row with no comma (reader), no rows the rows are the schedule
no class player { double value; }; any other class block (reader) the pattern GridLAB-D needs for <name>.value
a first row that is not absolute with a zone; an unknown zone; steps that differ; a value that is not a number S8-3
two players on one load record, or a phase off the player S8-1

Field tables (generated: fields_table(cls, records, fields=FIELDS), samples from the atom)

player

Player field type samples kind target
name Union[str, PlayerName] zipload copied ConformLoadGroup.name, ConformLoadSchedule.name; mRID = lg_ / ls_ + name
parent Optional[str] structural unset: a player read as .value plays into its own value; set raises
groupid Optional[str] untranscribed object header: a player has no place or service state
latitude Optional[str] untranscribed object header: a player has no place or service state
longitude Optional[str] untranscribed object header: a player has no place or service state
in_svc Optional[str] untranscribed object header: a player has no place or service state
out_svc Optional[str] untranscribed object header: a player has no place or service state
rank Optional[str] untranscribed object header: a player has no place or service state
flags Optional[str] untranscribed object header: a player has no place or service state
property Optional[str] structural unset: a player read as .value plays into its own value; set raises
file Optional[str] zipload.player structural its rows: startTime, timeStep and the points (the sidecar); unset raises
filetype Optional[str] structural unset: a player read as .value plays into its own value; set raises
mode Optional[str] structural unset: a player read as .value plays into its own value; set raises
loop Optional[int] 0 structural unset or 0; a repeated tape raises (a schedule has one pass)
all_events_delta Union[bool, Bool, NoneType] False untranscribed deltamode: an engine option

S9: load schedules (by the user's direction, 2026-11-21: Season x DayType, shared like a player)

A load base <schedule>*K scales K by a GridLAB-D schedule block, a set of cron rules (minutes hours days months weekdays [value]). GridLAB-D's reading, engine-checked (tests/test_cimtbl_schedule.py's probe and oracle): the ranges are inclusive, months count from 1, weekdays from 0 = Sunday, a rule with no value gives 1, a time no rule covers gives 0, and two rules covering one minute fail to load. One schedule drives many loads, as a player does, so it is the same group (S8-1), but its curve recurs by day of the year and of the week, which CGMES's SeasonDayTypeSchedule holds: one ConformLoadSchedule per Season and DayType, each a day of multipliers. The user chose this over nc_schedule's per-load EnergyConnectionRegularSchedule and over one expanded year (2026-11-21). Mappers: importer/cimtbl/schedule.py map_schedules (schedule_points, the points) and load.py (a base reading a schedule names its group). The reader keeps each block's statements as written (GlmModel.schedules). Tests: tests/test_cimtbl_schedule.py; atom tests/atoms/schedule/schedule.glm: - zip1: the first six hours of IEEE13_houses' ZIP1base_power (half-hour rules every day, no ;), 0 after; - heat: a winter (12,1-2) and the rest of the year, each with weekday and weekend days, a summer weekend with no rule (0); - waterdemand: read by no load (a house's), not mapped.

# the months whose days agree, in a run (December wraps to January)
Table Season: mRID, name, startDate, endDate
    season_01_12, 01-12, --01-01, --12-31
    season_03_11, 03-11, --03-01, --11-30
    season_12_02, 12-02, --12-01, --02-29

# the weekdays whose days agree in a season, in DayOfWeekKind words
Table DayType: mRID, name
    dt_all,     all
    dt_weekday, weekday
    dt_weekend, weekend

Table ConformLoadGroup: mRID, name
    lg_heat, heat
    lg_zip1, zip1

# value1: the schedule's value, a multiplier of each load's p and q, at each step from midnight (S9)
Table ConformLoadSchedule: mRID, name, startTime, timeStep (min), value1Unit, Season, DayType, ConformLoadGroup
    ls_heat_12_02_weekend, heat, 00:00:00, 1440, none, season_12_02, dt_weekend, lg_heat
    ls_heat_12_02_weekday, heat, 00:00:00, 60,   none, season_12_02, dt_weekday, lg_heat
    ...
    ls_zip1,               zip1, 00:00:00, 30,   none, season_01_12, dt_all,     lg_zip1

Decisions for S9

# question decision
S9-1 Shape a schedule a base reads as <schedule>*K → ConformLoadGroup lg_<schedule> (S8-1's prefix: a player and a schedule of one name raise), its loads ConformLoads with p, q K's split (S4a-2). A record's bases follow one source, a player or a schedule (S8-1)
S9-2 Days each (month, weekday) gets the day the rules give it (day_profiles). The months whose seven days agree, in runs of consecutive months (December's run joins January's), are a Season season_<first>_<last>: startDate --MM-01, endDate the last month's last day (February's 29th). Within a season, the weekdays whose days agree are a DayType dt_<name>, named in nc_schedule's DayOfWeekKind words: all, weekday, weekend, sunday ... saturday; another set joins the day names with _ (monday_wednesday). The name carries the weekdays: CIM's DayType has no other attribute
S9-3 A day one ConformLoadSchedule per (season, day type): ls_<schedule> when the schedule is one day, else ls_<schedule>_<first>_<last>_<day type>; startTime 00:00:00 (CIM: "the value can be a time of day"); timeStep (min) the coarsest divisor of a day on which the value only changes at step boundaries (coarsest_step); value1Unit none. A day no rule covers is a schedule of 0 (one point), as GridLAB-D gives 0
S9-4 Points RegularTimePoint rows in the Parquet sidecar with the players' (S8-4), numbered from midnight
S9-5 Schedules read the ones a load's base reads; the others (a house's) are not mapped, the master counts them (not mapped: schedule 1). A base naming a schedule the deck does not define raises (GridLAB-D would not load it)

Fail fast (S9)

condition why
a day of the month other than * no Season or DayType holds it
two rules on one minute GridLAB-D rejects the overlap
a field off *, a number, a-b, or a comma list of them, or out of its range; fewer than five fields; a value that is not a number the cron form
a nested block (weekday { ... }) not mapped