The LinkML schema¶
The GridLAB-D records are LinkML classes. The YAML is the single source of truth for what a GLM object holds and how
it is written; gridlabd.py is generated from it and never edited by hand. Unlike a hand-written schema, the YAML
here is scraped from the GridLAB-D C++ source, class by class, so it follows what GridLAB-D publishes. The schema
describes the native format only: it holds no CIM objects and no unit conversion. How each class reaches CIM is the
mapper's job (see The importer). The rules for writing a
native schema are in the
linkml-native-schema skill.
Layout¶
Everything is under
src/cimhub_gridlabd/schema/.
| Path | Holds |
|---|---|
linkml/main.yaml |
The root. It declares no classes; it imports types/common and every class file. |
linkml/types/common.yaml |
Complex (real and imag), the abstract glm_object, and the enums shared by the classes. |
linkml/powerflow/ |
The powerflow module, one file per class: node, meter, load, overhead_line, transformer, regulator, capacitor, ... (46 files). |
linkml/generators/ |
The generators module: inverter, solar, battery, ... (11 files). |
linkml/residential/ |
The residential module: house, waterheater, ZIPload, ... (19 files). |
linkml/tape/player.yaml |
The tape module's player, written by hand (see below). |
gridlabd.py |
The generated dataclasses, one per class: schema.OverheadLine, schema.Node, ... |
cpp_parser.py, property_parser.py, linkml_generator.py |
The scraper. |
README.md |
How to run the scraper for one module, and how the dataclasses are regenerated. |
One YAML file holds one class. A class name is its GLM type name (overhead_line, triplex_meter), unique across the
schema: glm_schema raises GLM schema class ... is defined twice on a repeat. The generated dataclass is the
PascalCase name (OverheadLine) with a class_name class variable holding the GLM name. Every class inherits
glm_object (directly, or through its GridLAB-D parent: overhead_line is a line, a link, a powerflow_object,
a glm_object).
glm_object holds the header properties GridLAB-D gives every object whatever its class (name, parent,
groupid, latitude, longitude, ...). No class publishes them, so the scrape does not see them: linkml_generator
writes them into types/common.yaml itself. name is the identifier, unique across a model, as GridLAB-D's names are.
player.yaml is also written by hand, from the tape module's published struct, because the scrape does not read that
form. It sits in tape/, which none of the scrapes of the other modules writes to.
A property named like a Python keyword is renamed in the slot and kept in the annotation: the GLM property from is
the slot from_node, with native_name: from.
The scraper¶
Three scripts, run in order, one GridLAB-D module at a time. They are run by hand and never imported by the package.
The commands, with the intermediate JSON files they pass along, are in
schema/README.md.
| Script | Reads | Writes |
|---|---|---|
cpp_parser.py --source <GridLAB-D checkout> --module <module> |
The C++ files of one module directory: each class's gl_publish_variable block, its parent class and its doc comment. |
extracted_<module>_classes.json |
property_parser.py --input ... --output ... |
The raw publish blocks. It tokenizes each block on commas at paren depth 0 and walks the tokens as a state machine, so wrapped declarations parse the same. It raises on a token it cannot classify instead of dropping the property. | parsed_<module>_classes.json: typed properties (name, C++ type, LinkML range, unit, description, enum values). |
linkml_generator.py --input ... --output .../linkml --module <module> |
The parsed JSON. | One YAML per class in linkml/<module>/; the enums merged into types/common.yaml; the module's imports appended to main.yaml. Both are updated idempotently, so a rerun for a new module leaves earlier modules alone. |
GridLAB-D itself is not vendored: --source points at a checkout, and the schema's license is BSD-3-Clause, as
GridLAB-D's.
Regenerating gridlabd.py¶
After any change to a YAML file, regenerate the module and commit both together:
scripts/gen-schema.sh maps each
package to its root YAML and generated module (for gridlabd, schema/linkml/main.yaml to schema/gridlabd.py),
runs uvx --python 3.13 --from linkml gen-python --no-generation-date, and copies the result over the module. It
runs linkml through uvx, so it never touches uv.lock, and --no-generation-date keeps the output the same from run
to run, so the diff shows only what the YAML changed. An unknown package name exits with the list of known ones.
The first regeneration after a LinkML upgrade also changes the header: the committed module was generated by an older
LinkML, so the Generation date line goes and metamodel_version changes. Nothing else differs from the committed
file when the YAML has not.
After regenerating:
- run
scripts/test-all.sh gridlabd: a mapper'scheck_fields(FIELDS, NATIVE_CLASS)test fails on a slot the regeneration added or removed, andlink.classifyandbus.classifyraise at import time on a slot no classification claims, soFIELDS(and the exporter'sSLOTS) are updated in the same commit; - never edit
gridlabd.pyby hand; the next regeneration would erase the edit. A fix goes in the YAML, then regenerate. A change to a scraped class is overwritten by the next scrape of its module, so a change that has to survive belongs in the scraper (linkml_generator.py) or in a hand-written file.
The annotations the code reads¶
gen-python does not carry LinkML annotations into the dataclasses. glm_schema.py reads them from the YAML at run
time and indexes them per dataclass, walking is_a so an inherited slot (nominal_voltage on a triplex_node, from
node) carries its annotations. (The core get_schema_annotations matches a class by its Python __name__, which is
the PascalCase name here and never the YAML key, so this package does not use it.)
| Where | Key | Read by |
|---|---|---|
| slot annotation | native_name |
glm_schema.slots (the SlotInfo.native_name), then glm_schema.slot_for_property (the reader's map from a GLM property to its slot), GlmWriter.serialize (the property name written), importer.cimtbl.catalog.native_name (error messages). The scrape appends the unit (primary_voltage[V]); glm_schema strips that suffix. |
slot, unit.ucum_code |
the declared unit | glm_schema.slots (SlotInfo.unit), then GlmModel.unit (the unit a value is stored in when none was written) and exporter.units.glm_unit. registry_unit respells GridLAB-D's unit names for pint. |
| slot annotation | glm_default |
glm_schema.slots (SlotInfo.default). No YAML sets it yet and no code reads default: the reader leaves a GLM default unset, and the mappers name the defaults they need. |
| slot annotation | order |
Written by the scraper (the property's position, 0 for the header slots). No code reads it: a deck is written in the order of the dataclass fields, which is the YAML's attribute order. |
| slot annotation | value_type, precision |
Written by the scraper (the C++ type family, and 6 for a double). No code reads them. |
| slot | range |
The reader reads it from the dataclass type hints (_slot_kinds: Complex, float, int, bool, an enum or text) to decide how to read a value. |
| slot | identifier |
name on glm_object; the reader and GlmModel key records by it. |
from cimhub_gridlabd import glm_schema
from cimhub_gridlabd.schema import gridlabd as schema
print(glm_schema.slots(schema.OverheadLine)["from_node"]) # SlotInfo(native_name='from', unit=None, default=None)
print(glm_schema.slot_for_property(schema.OverheadLine)["from"]) # from_node
print(glm_schema.slots(schema.TriplexLineConfiguration)["insulation_thickness"].unit) # in
print(glm_schema.registry_unit("Ohm/mile")) # ohm/mile
A default is never written as ifabsent: that would make the reader fill every slot, and the writer then write them
all back. An unset GLM property stays unset.
The CIM mapping slots¶
Each class the package converts, and each property it copies, maps, derives or reads structurally, names its cim18v17 counterpart, as the OpenDSS schema does:
| slot | meaning | example |
|---|---|---|
exact_mappings |
the same concept, copied or mapped | line.length → cim:Conductor.length |
close_mappings |
a derived value, or one of several targets | capacitor.capacitor_A → cim:ShuntCompensator.nomQ; load → cim:ConformLoad when a player drives it |
related_mappings |
a structural reference | link.from_node → cim:Terminal.ConnectivityNode |
A short comments entry says where the value lands on import (the .cimtbl column and its unit) and how the export
writes it back. A class the package does not convert says so in its comment instead. The slots are documentation:
no code reads them, and the schema reference shows them. The mapping itself is the mapper's FIELDS and the
exporter's SLOTS, and the design record is the import and export
specs. An inherited property is mapped once, on the class that declares it.
The schema reference¶
The reference pages in docs/schema/ are generated, never committed (docs/.gitignore lists schema/).
scripts/build-docs.sh generates them
before it builds the site:
scripts/build-docs.sh gridlabd --serve # generate docs/schema/, then serve the site
scripts/build-docs.sh gridlabd # generate, then mkdocs build --strict
For gridlabd the script removes cimhub_gridlabd/docs/schema and runs
uvx --python 3.13 --from linkml gen-doc -d cimhub_gridlabd/docs/schema \
cimhub_gridlabd/src/cimhub_gridlabd/schema/linkml/main.yaml
gen-doc writes schema/index.md and one page per class and enum. mkdocs.yml puts schema/index.md in the nav as
the Schema reference and lists schema/* under not_in_nav, so the per-class pages are reached from the index and
the build does not warn about them. Building the site with mkdocs alone, without the script, fails the strict build
on the missing schema/index.md.