What converts¶
Which GridLAB-D classes import and export today. The source of truth is the code: the importer's mappers are listed
in MAPPING_ORDER in importer/glm_to_cimtbl.py, the classes it classifies in CLASSIFIED in the same file, and the
exporter's modules in EXPORT_ORDER in exporter/cim_to_glm.py. The table below follows those lists. Property-level
detail is in the import mapping and the export mapping, where every
property is classified. Each class links to the conversion reference page that describes it.
Classes that convert¶
The importer writes one .cimtbl file per part, named for the class (overhead_line.cimtbl), and the master imports
them in this order: catalogs before the equipment that uses them. Two parts come first, bus.cimtbl and
source.cimtbl, and the core's shared zip_fractions.cimtbl (the ZIP load models) follows them. A part with no
objects is not written.
| GLM class | CIM class (cim18v17) | Import | Export | Reference |
|---|---|---|---|---|
node |
ConnectivityNode |
bus.cimtbl |
buses |
buses |
meter |
ConnectivityNode: a child bus is its root's node |
bus.cimtbl |
not written | buses |
triplex_meter |
ConnectivityNode: as meter |
bus.cimtbl |
not written | buses |
substation |
ConnectivityNode, and the EnergySource of the swing bus (a SWING node is a source too) |
bus.cimtbl, source.cimtbl |
buses |
buses |
overhead_line_conductor |
OverheadWireInfo |
yes | line |
lines |
underground_line_conductor |
ConcentricNeutralCableInfo, TapeShieldCableInfo, or OverheadWireInfo when it has neither |
yes | line |
lines |
triplex_line_conductor |
OverheadWireInfo |
yes | line |
lines |
line_spacing |
ConductorDistanceSpacing (template) with ConductorDistances |
yes | line |
lines |
line_configuration |
WireConfiguration with WireSequenceConfigurations (geometry), or PerLengthPhaseImpedance in a template WireConfiguration (matrix) |
yes | line |
lines |
triplex_line_configuration |
WireConfiguration on a ConductorDistanceSpacing derived from its diameters |
yes | line |
lines |
transformer_configuration |
TransformerTankConfiguration |
yes | transformer |
transformers |
overhead_line |
ACLineSegment by its configuration's WireConfiguration |
yes | line |
lines |
underground_line |
ACLineSegment |
yes | line |
lines |
triplex_line |
ACLineSegment |
yes | line |
lines |
switch |
LoadBreakSwitch |
yes | switch |
lines |
fuse |
Fuse |
yes | switch |
lines |
recloser |
Recloser |
yes | switch |
lines |
series_reactor |
SeriesCompensator |
yes | series_reactor |
lines |
transformer |
PowerTransformer with a TransformerTank and PowerTransformerEnds |
yes | transformer |
transformers |
regulator |
VoltageRegulator with AutoTransformerEnds, a RatioTapChanger and a TapChangerControl |
yes | regulator |
transformers |
player |
ConformLoadGroup and ConformLoadSchedule, with the points in time_points |
yes | player |
loads |
schedule |
ConformLoadGroup, and a ConformLoadSchedule per Season and DayType |
yes, those a load's base reads | schedule |
loads |
load |
EnergyConsumer, or ConformLoad when its base reads a player or schedule |
yes | load |
loads |
triplex_load |
EnergyConsumer or ConformLoad, one for the legs and one for the 240 V part |
yes | load |
loads |
triplex_node |
ConnectivityNode (bus.cimtbl), and an EnergyConsumer for the power on it |
bus.cimtbl, triplex_node.cimtbl |
buses; its power as a triplex_load |
loads |
capacitor |
LinearShuntCompensator, with a RegulatingControl for a voltage control |
yes | capacitor |
loads |
inverter |
PowerElectronicsConnection with a PhotoVoltaicUnit or BatteryUnit |
yes | inverter |
DER |
Three classes are classified with another class's part and have no file of their own:
| GLM class | CIM class | Import | Export | Reference |
|---|---|---|---|---|
regulator_configuration |
the RatioTapChanger and TapChangerControl of its regulator |
in regulator.cimtbl |
regulator |
transformers |
solar |
the SolarPanelInfo, SolarArrayInfo and PhotoVoltaicUnit of its inverter |
in inverter.cimtbl |
inverter |
DER |
battery |
the BatteryInfo and BatteryUnit of its inverter |
in inverter.cimtbl |
inverter |
DER |
The exporter's modules, in EXPORT_ORDER: buses, line, switch, series_reactor, transformer, regulator,
player, schedule, load, capacitor, inverter. The switch module also writes a sectionalizer for a CIM
Sectionaliser.
And the deck's settings:
| In the deck | CIM | Import | Export |
|---|---|---|---|
module powerflow { nominal_frequency ...; }, or #set powerflow::nominal_frequency=... |
BaseFrequency |
yes; 60 Hz when unset, noted in the master | the module's nominal_frequency |
| the buses' voltages | one BaseVoltage per distinct bus voltage the topology walk finds |
yes | each bus's nominal_voltage from its BaseVoltage |
| the swing bus | Substation, Feeder, and the NormalHeadFeeder of each link's terminal on it |
yes | one substation with bustype SWING (a one-phase swing: a node with bustype SWING) |
Notes:
- A
SWINGbus becomes anEnergySourcewith a stiff default impedance. The exporter writes one swing and does not write the source's impedance. TwoEnergySources raise. - A load that reads
<player>.value*Kor<schedule>*Kimports as aConformLoad. See Players and schedules. - A plain
triplex_node'spower_12is imported as anEnergyConsumer. It exports as atriplex_load. - A regulator with
control_level INDIVIDUAL(GridLAB-D's default) imports as one single-phase unit per wired phase, and aBANKregulator as one gang unit. The exporter writes units that the importer split back as oneregulator. - A switch, fuse or recloser has one GridLAB-D state,
status, which is both itsopenandnormalOpenstate. A per-phase state that differs from it raises. - On export, a configuration is written once for each way a line uses it, so one that no equipment uses is not written.
Classes that do not convert¶
The reader parses every class in the schema. The classes below have no mapper, so the importer skips them. None has an exporter module either. The groups follow the schema's modules.
Residential (house and appliances):
| Group | GLM classes |
|---|---|
| The house | house, house_a |
| Appliances and end uses | appliance, residential_enduse, ZIPload, lights, plugload, occupantload, clotheswasher, dishwasher, dryer, freezer, microwave, range, refrigerator, waterheater |
| Storage and charging | thermal_storage, evcharger, evcharger_det |
Generators:
| Group | GLM classes |
|---|---|
| Machines | diesel_dg, windturb_dg, rectifier |
| Storage and dynamic inverters | energy_storage, inverter_dyn |
| Controls | central_dg_control, controller_dg, sync_ctrl |
Powergrid objects:
| Group | GLM classes |
|---|---|
| Dumps and meters | billdump, currdump, voltdump, impedance_dump, jsondump, power_metrics, emissions |
| Checks and control | fault_check, sync_check, restoration, volt_var_control, load_tracker |
| Motors and loads | motor, performance_motor, vfd, pqload |
| Links | series_compensator |
A type the schema does not have is not parsed at all. The recorders and collectors of the tape module are the usual
case: the schema has only player from that module. The reader counts the type and reads none of its properties.
What happens to them on import¶
A deck that uses one of these still imports. The master's comment lists every GridLAB-D type no mapper read, with its count, so nothing disappears silently:
The count includes the types the schema lacks (recorder), and a schedule that no load's base reads (a house's).
What the class would have configured is absent from the CIM network: a house and its appliances are not loads,
and a recorder has no CIM form. The importer reads none of their properties, so an expression such as LIGHTS*1.2 on one of them does not raise: it
raises only on a class that converts.
Properties that raise¶
Inside a class that converts, a property can be classified as raising when set. The importer refuses it instead of dropping it. The complete list is the classification table in each section of the import mapping; each raising property says in its row what deck would justify mapping it. Two rules apply to every class:
- A numeric property that holds an expression the reader could not evaluate raises on a converting class, naming the
object, its file and line and the property. The one exception is a load's
base_power, which may be<player>.value*Kor<schedule>*K. - A bus's own load accumulators (
constant_power_Xand the like on anode) raise: put the load on aloadobject.
Export limits¶
Export is the inverse of the same mappings, with these limits:
- Conducting equipment of a CIM class no exporter module handles raises, naming the class and count. A
BusbarSectionis the exception: it is its node's bus. - A CIM property with no GridLAB-D slot is written as GridLAB-D's default. The export mapping
marks each one
unset. Round trip lists the differences that follow. - A