Conversion reference

What happens to each GridLAB-D class when a .glm becomes CIM and when CIM becomes a .glm. The pages are lookup tables, one section per GLM class. For the steps of a conversion see the user guide; for the code behind it, the developer docs; for the complete design records, the import mapping and the export mapping.

The core site documents what the spoke is built on: the getters, the .cimtbl contract, the canonical shapes and its reference. All CIM names here are cim18v17.

Which classes convert

Import is the importer's MAPPING_ORDER plus the buses and sources it writes first; export is the exporter's EXPORT_ORDER. A GLM class in neither is read by GlmReader and never converted. The importer counts it in the master's not mapped: comment, so nothing disappears silently, and the exporter has nothing to write it from.

GLM class CIM classes Import Export Page
module powerflow nominal_frequency BaseFrequency yes yes buses
node, meter ConnectivityNode, BaseVoltage yes yes (both come back as node) buses
triplex_node, triplex_meter ConnectivityNode, BaseVoltage yes yes (both come back as triplex_node) buses
substation, a bus with bustype SWING EnergySource, BasePower yes yes (as a substation) buses
overhead_line_conductor OverheadWireInfo, OperationalLimitSet, CurrentLimit yes yes lines
underground_line_conductor ConcentricNeutralCableInfo, TapeShieldCableInfo or OverheadWireInfo yes yes lines
triplex_line_conductor OverheadWireInfo yes yes lines
line_spacing ConductorDistanceSpacing, ConductorDistance yes yes lines
line_configuration WireConfiguration, WireSequenceConfiguration; or PerLengthPhaseImpedance, PhaseImpedanceData yes yes lines
triplex_line_configuration WireConfiguration, WireSequenceConfiguration, ConductorDistanceSpacing yes yes lines
overhead_line, underground_line, triplex_line ACLineSegment, OperationalLimitSet, CurrentLimit yes yes lines
switch LoadBreakSwitch yes yes (also every Switch class but the three below) lines
fuse Fuse yes yes lines
recloser Recloser yes yes lines
sectionalizer Sectionaliser yes yes lines
series_reactor SeriesCompensator yes yes lines
transformer_configuration TransformerTankConfiguration, TransformerBankConfiguration, TransformerTankEnd, TransformerLug, TransformerWinding yes yes transformers
transformer PowerTransformer, TransformerTank, PowerTransformerEnd, TransformerPhaseEnd yes yes (from a PowerTransformer, or an AutoTransformer that is not a VoltageRegulator) transformers
regulator_configuration its values on every unit of the regulators that name it yes yes transformers
regulator VoltageRegulator, AutoTransformerEnd, TransformerMeshImpedance, TapChangerControl, RatioTapChanger yes yes transformers
load, triplex_load, a triplex_node's power_1, power_2, power_12 EnergyConsumer, LoadResponseCharacteristic yes yes loads
capacitor LinearShuntCompensator, RegulatingControl yes yes loads
player, schedule ConformLoadGroup, ConformLoadSchedule, time points in the sidecar tables yes yes (with time_points) loads
inverter, solar, battery PowerElectronicsConnection, PhotoVoltaicUnit, BatteryUnit yes yes DER
every other GLM class (house, recorder, ...) none no no

On export a CIM switch of a class other than Fuse, Recloser and Sectionaliser (LoadBreakSwitch, Breaker, Disconnector, Jumper, a plain Switch) is a GLM switch, since GridLAB-D has no breaker. Conducting equipment of a class no exporter module writes raises (no GLM export yet for {...}), so nothing is dropped silently; a BusbarSection is its node's bus and needs no object.

How to read a section

Each section starts with the CIM classes and the .cimtbl shape a GLM class becomes, then a table of its GLM properties, its fail-fast rules, what a round trip changes, and a short excerpt copied from a golden file in cimhub_gridlabd/tests/atoms/. A property row has three columns:

Column Says
property the GLM property, as the schema names it (rating.summer.continuous in a deck is the slot rating_summer_continuous)
import what the importer does with it: the field class, and for a copied value the CIM Class.attribute and the unit in the .cimtbl header
export what the exporter does: how it is written back and which getter it reads

Properties the mapper does not read, and the exporter does not write, are grouped in one row at the foot of the table.

Excerpts are the golden files' text, with the design-record IDs that the artifact comments carry left out.

The five field classes (import)

Every property of a mapped GLM class has exactly one of these, and a test checks that the classification covers every slot of the schema.

Class Means
copied the value lands unchanged in a column, with its source unit in the header (length (ft), rAC50 (ohm/mile))
mapped the value goes through a code table, such as Type A to typeA
structural the value decides rows: one record becomes several rows, or a value sits on one specific row, or it names another object
derived the value is computed by a named, tested function, because CIM has no attribute for the source quantity (b_from_c, radius_from_diameter, line_voltage)
untranscribed CIM has no home for it; it is listed in a comment on the artifact, never dropped silently

Export slot kinds

Every slot of a GLM class is listed by the exporter, so nothing is dropped unnoticed. The export column shows one of:

Kind Means
written the value comes from a getter and is written
unset CIM cannot hold it, so the slot is left out and GridLAB-D's default applies
not mapped another form of the same data is written instead (the impedance, not its real and imaginary parts)

Units and fail-fast

Values are copied in the deck's own units and the unit is in the .cimtbl column header; cimtables converts them when it builds the model. A value written with an inline unit (length 21 m) gets that unit in its header, so one artifact holds a table per unit. On export every getter converts once, through get_qty, to the unit the GLM slot declares (ft, ohm/mile, V, kVA). See Units, bases and signs on the core site.

"Raises" means fail fast: the mapper stops with a ValueError that names the class, the object and the rule, and nothing is guessed. Unknown fields, unmapped enumerations and unresolved references all raise. IDs are quoted, never sanitized, on import; on export glm_safe_name replaces each run of characters GridLAB-D cannot take in a name (whitespace, ., :, quotes, ;, braces, $) with _, and two objects that land on one name raise. A value the reader kept as an expression (LIGHTS*1.2) in a property a mapper reads raises too, naming the object, file and line.

Names

On export an object is named by name_source: "name" (the CIM name), "mrid" or "uri"; else $CIMHUB_NAME_SOURCE, else "mrid". A model that came from GLM round-trips under name_source="name", and the sections below assume it.

On import an mRID is a prefix plus the GLM name: ln_ lines, sw_ switches, fuses and reclosers, rx_ series reactors, xf_ transformers and regulator units, xc_ transformer configurations, xb_ banks, rc_ regulator controls, ohc_, ugc_ and tpc_ conductors, spc_ spacings, wc_ and lc_ configurations, src_ sources. Buses are the exception: a bus's mRID is its GLM name, with no prefix.

Pages

Page Covers
Buses, meters and the source node, meter, triplex_node, triplex_meter, substation and the swing EnergySource; the topology walk that gives buses and BaseVoltages; the master (frequency, containers, feeder head)
Lines, conductors and switches the three conductor catalogs; line_spacing; line_configuration and triplex_line_configuration; overhead_line, underground_line, triplex_line; switch, fuse, recloser, sectionalizer; series_reactor
Transformers and regulators transformer_configuration and transformer (connect types, center tap, banks); regulator_configuration and regulator
Loads, capacitors, players and schedules load, triplex_load, ZIP fractions; capacitor; player; schedule
Inverters, solar and batteries inverter, solar, battery