Skip to content

GridLAB-D GLM File Format Schema

Complete LinkML schema for GridLAB-D GLM (GridLAB-D Model) file format.

This schema defines the structure of GridLAB-D configuration files including modules, objects, and their properties.

Generated from C++ source code with 77 classes: 46 from the powerflow module, 11 from generators, 19 from residential and 1 from tape.

Features: - Complete inheritance chains - Property annotations for serialization - Physical units (ft, VA, W, etc.) - Enumeration definitions - Documentation from source code

Follows the CIMHub architecture for round-trip conversion with CIM.

URI: https://gridlabd.org/schema/glm

Name: gridlabd_glm

Classes

Class Description
Complex Complex number with real and imaginary components
GlmObject The header properties GridLAB-D gives every object (core/object
        Battery Copyright (C) 2008 Battelle Memorial Institute
        Billdump Copyright (C) 2008 Battelle Memorial Institute
        CentralDgControl Copyright (C) 2008 Battelle Memorial Institute
        ControllerDg GridLAB-D controller_dg class
        Currdump Copyright (C) 2008 Battelle Memorial Institute
        DieselDg Copyright (C) 2008 Battelle Memorial Institute
        EnergyStorage **** QSTS Updates might go here - this may also be called by deltamode
        ImpedanceDump Copyright (C) 2008 Battelle Memorial Institute
        Inverter Copyright (C) 2008 Battelle Memorial Institute
        InverterDyn Common items ***
        Jsondump Copyright (C) 2017 Battelle Memorial Institute
        LineConfiguration Copyright (C) 2008 Battelle Memorial Institute
                TriplexLineConfiguration Copyright (C) 2008 Battelle Memorial Institute
        LineSpacing Copyright (C) 2008 Battelle Memorial Institute
        LoadTracker GridLAB-D load_tracker class
        OverheadLineConductor Copyright (C) 2008 Battelle Memorial Institute
        Player The tape module's player: it plays a file of time,value rows into its parent'...
        PowerMetrics Copyright (C) 2009 Battelle Memorial Institute
        PowerflowObject Copyright (C) 2008 Battelle Memorial Institute
                Emissions Copyright (C) 2011 Battelle Memorial Institute
                FaultCheck Copyright (C) 2009 Battelle Memorial Institute
                Link Copyright (C) 2008 Battelle Memorial Institute
                        Fuse Copyright (C) 2008 Battelle Memorial Institute
                        Line Copyright (C) 2008 Battelle Memorial Institute
                                OverheadLine Copyright (C) 2008 Battelle Memorial Institute
                                TriplexLine Copyright (C) 2008 Battelle Memorial Institute
                                UndergroundLine Copyright (C) 2008 Battelle Memorial Institute
                        Regulator Copyright (C) 2008 Battelle Memorial Institute
                        SeriesCompensator **************** Code injection point *****************
                        SeriesReactor Copyright (C) 2009 Battelle Memorial Institute
                        Switch Copyright (C) 2008 Battelle Memorial Institute
                                Recloser Copyright (C) 2011 Battelle Memorial Institute
                                Sectionalizer Copyright (C) 2011 Battelle Memorial Institute
                        Transformer Copyright (C) 2008 Battelle Memorial Institute
                        Vfd Copyright (C) 2017 Battelle Memorial Institute
                Node Copyright (C) 2008 Battelle Memorial Institute
                        Capacitor Copyright (C) 2008 Battelle Memorial Institute
                        Load Copyright (C) 2008 Battelle Memorial Institute
                                Pqload Copyright (C) 2008 Battelle Memorial Institute
                        Meter Copyright (C) 2008 Battelle Memorial Institute
                        Motor constructor
                        PerformanceMotor REQUIRED: allocate and initialize an object
                        Substation Copyright (C) 2009 Battelle Memorial Institute
                SyncCheck Implements sychronization check functionality for switches to close
                TriplexNode Copyright (C) 2008 Battelle Memorial Institute
                        TriplexLoad Copyright (C) 2013 Battelle Memorial Institute
                        TriplexMeter Copyright (C) 2008 Battelle Memorial Institute
                VoltVarControl Implemented integrated Volt-VAr control scheme detailed in:
        Rectifier Copyright (C) 2008 Battelle Memorial Institute
        RegulatorConfiguration Copyright (C) 2008 Battelle Memorial Institute
        ResidentialEnduse The base of every residential enduse (ZIPload, waterheater, lights, house,
                Appliance Copyright (C) 2012 Battelle Northwest
                Clotheswasher Copyright (C) 2008 Battelle Memorial Institute
                Dishwasher Copyright (C) 2008 Battelle Memorial Institute
                Dryer Copyright (C) 2008 Battelle Memorial Institute
                Evcharger Copyright (C) 2008 Battelle Memorial Institute
                EvchargerDet Copyright (C) 2019 Battelle Memorial Institute
                Freezer Copyright (C) 2008 Battelle Memorial Institute
                House Copyright (C) 2008 Battelle Memorial Institute
                HouseA Copyright (C) 2008 Battelle Memorial Institute
                Lights Copyright (C) 2008 Battelle Memorial Institute
                Microwave Copyright (C) 2008 Battelle Memorial Institute
                Occupantload Copyright (C) 2008 Battelle Memorial Institute
                Plugload Copyright (C) 2008 Battelle Memorial Institute
                Range Copyright (C) 2008 Battelle Memorial Institute
                Refrigerator Copyright (C) 2008 Battelle Memorial Institute
                ThermalStorage Copyright (C) 2008 Battelle Memorial Institute
                Waterheater Copyright (C) 2008 Battelle Memorial Institute
                ZIPload Copyright (C) 2009 Battelle Memorial Institute
        Restoration Copyright (C) 2009 Battelle Memorial Institute
        Solar // Assumptions:
        SyncCtrl Implements sychronization control functionality for the sychronization check
        TransformerConfiguration Copyright (C) 2008 Battelle Memorial Institute
        TriplexLineConductor Copyright (C) 2008 Battelle Memorial Institute
        UndergroundLineConductor Copyright (C) 2008 Battelle Memorial Institute
        Voltdump Copyright (C) 2008 Battelle Memorial Institute
        WindturbDg Copyright (C) 2008 Battelle Memorial Institute

Slots

Slot Description
a
A3
A4
a_coeff a coefficient for module temperature correction formula
A_ES_pu Exponential zone amplitude, per unit
A_sat flux saturation parameter, A - single-phase model
actual_charge_rate Actual charge rate of the vehicle - may be ramp limited
actual_dishwasher_demand
actual_dryer_demand
actual_load the actual load based on the current voltage across the coils
actual_power variable to pull actual load as function of voltage
actual_voltage
additional_controls LEGACY MODEL: In conjunction with POWER_DRIVEN, VOLTAGE_CONTROLLED, and POWER...
adj_cooling_cap
adj_cooling_cop
adj_heating_cap
adj_heating_cop
aging_constant the aging rate slope for the transformer insulation
aging_granularity maximum timestep before updating thermal and aging model in seconds
air_density COP: Estimated air density
air_heat_capacity air thermal mass
air_heat_fraction fraction of heat gain/loss that goes to air (as opposed to mass)
air_mass air mass
air_temperature indoor air temperature
air_volume air volume
airchange_per_hour number of air-changes per hour
airchange_UA additional UA due to air infiltration
all_events_delta Every row's time enters deltamode
allowed_vv_action CHECKPOINT_VAR: internal variable for allowed_vv_action
ambient_temperature ambient temperature in degrees C
Angle_PLL_A DELTAMODE: phase angle of terminal voltage measured by PLL, phase A
Angle_PLL_B DELTAMODE: phase angle of terminal voltage measured by PLL, phase B
Angle_PLL_C DELTAMODE: phase angle of terminal voltage measured by PLL, phase C
area
area_per_door CHECKPOINT_VAR: internal variable for area per door in square feet
armed Flag to arm the synchronization close
arrival_at_home Time vehicle arrives at home - HHMM
arrival_at_work Time vehicle arrives at work - HHMM
ASAI Displays annual AISI values as per IEEE 1366-2003
ASAI_int Displays AISI values over the period specified by base_time_value as per IEEE...
aspect_ratio aspect ratio of the home's footprint
aux_heat_deadband temperature offset from standard heat activation to auxiliary heat activation
aux_heat_temperature_lockout temperature at which auxiliary heat will not engage above
aux_heat_time_delay time required for heater to run until auxiliary heating engages
auxiliary_heat_capacity installed auxiliary heating capacity
auxiliary_strategy auxiliary heating activation strategies
auxiliary_system_type
b
b12 CHECKPOINT_VAR: internal variable for b12
b23 CHECKPOINT_VAR: internal variable for b23
b34 CHECKPOINT_VAR: internal variable for b34
b_coeff b coefficient for module temperature correction formula
B_ES_pu Exponential zone time constant inverse, per unit
b_sat flux saturation parameter, b - single-phase model
band_center band center setting of regulator control
band_width band width setting of regulator control
base_efficiency LEGACY MODEL: the efficiency of the battery at rated voltaged and current
base_power base power
base_power_1 in similar format as ZIPload, this represents the nominal power on phase 1 be...
base_power_12 in similar format as ZIPload, this represents the nominal power on phase 12 b...
base_power_2 in similar format as ZIPload, this represents the nominal power on phase 2 be...
base_power_A in similar format as ZIPload, this represents the nominal power on phase A be...
base_power_B in similar format as ZIPload, this represents the nominal power on phase B be...
base_power_C in similar format as ZIPload, this represents the nominal power on phase C be...
base_time_value time period over which _int values are claculated
battery_capacity INTERNAL BATTERY MODEL: the rated battery capacity of the battery
battery_load INTERNAL BATTERY MODEL: the current power output of the battery
battery_size Full capacity of battery
battery_soc FOUR QUADRANT MODEL: The state of charge of an attached battery
battery_SOC State of charge of battery
battery_state Describes the current state of the battery
battery_type INTERNAL BATTERY MODEL: the type of the battery
behaving_as_swing Indicator flag for if a bus is behaving as a reference voltage source - valid...
bias Exciter bias state variable
bill_day day of month bill is to be processed (currently limited to days 1-28)
bill_mode Billing structure desired
Biomass_CO2
Biomass_Conv_Eff
Biomass_emissions_CO2
Biomass_emissions_NOx
Biomass_emissions_SO2
Biomass_Max_Out
Biomass_NOx
Biomass_Order
Biomass_Out
Biomass_SO2
blade_diam COP: Diameter of blades
blade_diameter COP: Diameter of blades
breaker_amps the rated breaker amperage
breaker_val Amperage of connected breaker
busflags flag indicates node has a source for voltage, i
bustype defines whether the node is a PQ, PV, or SWING node
c
c1
c11
c12
c13
c2
c21
c22
c23
c31
c32
c33
c_0 MULTIPOINT EFFICIENCY MODEL: the first coefficient in the efficiency curve
c_1 MULTIPOINT EFFICIENCY MODEL: the second coefficient in the efficiency curve
c_2 MULTIPOINT EFFICIENCY MODEL: the third coefficient in the efficiency curve
c_3 MULTIPOINT EFFICIENCY MODEL: the fourth coefficient in the efficiency curve
C_pu DELTAMODE: capacitance of dc bus
CAIDI Displays annual CAIDI values as per IEEE 1366-2003
CAIDI_int Displays SAIDI values over the period specified by base_time_value as per IEE...
cap_A_switch_count number of switch operations on Phase A
cap_B_switch_count number of switch operations on Phase B
cap_C_switch_count number of switch operations on Phase C
cap_nominal_voltage Nominal voltage for the capacitor
capacitor_A Capacitance value for phase A or phase AB
capacitor_B Capacitance value for phase B or phase BC
capacitor_C Capacitance value for phase C or phase CA
capacitor_delay Default capacitor time delay - overridden by local defintions
capacitor_list List of controllable capacitors on the system separated by commas
capacitor_speed percentage speed of nominal when starting capacitor kicks in
capacity
ceiling_height average ceiling height
cgu_freq_set_cv The output of the PI controller that adjusts the frequency difference (i
cgu_freq_set_mpv The measured process variable (i
cgu_volt_set_cv The output of the PI controller that adjusts the voltage magnitude difference...
cgu_volt_set_mpv The measured process variable (i
charge
charge_at_work
charge_lockout_time FOUR QUADRANT MODEL: Lockout time when a charging operation occurs before ano...
charge_off_threshold FOUR QUADRANT MODEL: power level at which the inverter should cease charging ...
charge_on_threshold FOUR QUADRANT MODEL: power level at which the inverter should try charging th...
charge_threshold FOUR QUADRANT MODEL: Level at which all inverters in the group will begin cha...
charge_throttle
charger_efficiency Efficiency of the charger in terms of energy in to battery stored
charger_enabled Flag to indicate if the charger is working, or disconnected due to SAE J2894/...
charger_type
charging_efficiency Efficiency of charger (ratio) when charging
check_defrost CHECKPOINT_VAR: internal variable for defrost checking
check_DO
check_icemaking CHECKPOINT_VAR: internal variable for icemaker checking
check_mode Frequency of fault checks
check_power_high LEGACY MODEL: low set point of dead band for load following at lower temperat...
check_power_low LEGACY MODEL: high set point of dead band for load following at lower tempera...
checkRampRate_reactive DELTAMODE: Boolean used to indicate whether check the ramp rate
checkRampRate_real DELTAMODE: Boolean used to indicate whether check the ramp rate
circuit_split
circular_flow_rate MULTILAYER MODEL: Heuristic flow activated once the heating elements turn on
climate climate object used to describe thermal model ambient temperature
climate_object_found CHECKPOINT_VAR: internal variable for climate_object_found
clotheswasher_run_prob
clothesWasherPower
CmpKpf Real power frequency sensitivity in puP/puf
CmpKqf Reactive power frequency sensitivity in puQ/puf
CO2_emission Total CO2 emissions (lbs) based on fuel usage
Coal_CO2
Coal_Conv_Eff
Coal_emissions_CO2
Coal_emissions_NOx
Coal_emissions_SO2
Coal_Max_Out
Coal_NOx
Coal_Order
Coal_Out
Coal_SO2
coil_only_check1
coil_only_check2
coil_only_check3
compensator_r_setting_A Line Drop Compensation R setting of regulator control (in volts) on Phase A
compensator_r_setting_B Line Drop Compensation R setting of regulator control (in volts) on Phase B
compensator_r_setting_C Line Drop Compensation R setting of regulator control (in volts) on Phase C
compensator_x_setting_A Line Drop Compensation X setting of regulator control (in volts) on Phase A
compensator_x_setting_B Line Drop Compensation X setting of regulator control (in volts) on Phase B
compensator_x_setting_C Line Drop Compensation X setting of regulator control (in volts) on Phase C
compressor_count
compressor_defrost_time
compressor_off_normal_energy
compressor_off_normal_power
compressor_on
compressor_on_normal_energy
compressor_on_normal_power
condition
conductor_1 conductor type for phase 1
conductor_2 conductor type for phase 2
conductor_A
conductor_B
conductor_C
conductor_diameter Diameter of conductor
conductor_gmr Geometric mean radius of the conductor
conductor_N
conductor_resistance Resistance of conductor in ohm/mile
configuration
connect_type Designation of connection style
connected_house house object to monitor the XXX property to determine if the motor is running
connected_house_assumed_mode Assumed operation mode of connected_house object
constant_admittance the constant admittance portion of the total load
constant_current the constant current portion of the total load
constant_current_1 constant current load on phase 1, specified as Amps
constant_current_12 constant current load on phase 12, specified as Amps
constant_current_12_reac constant current load on phase 12, imaginary only, specified as Amps
constant_current_12_real constant current load on phase 12, real only, specified as Amps
constant_current_1_reac constant current load on phase 1, imaginary only, specified as Amps
constant_current_1_real constant current load on phase 1, real only, specified as Amps
constant_current_2 constant current load on phase 2, specified as Amps
constant_current_2_reac constant current load on phase 2, imaginary only, specified as Amps
constant_current_2_real constant current load on phase 2, real only, specified as Amps
constant_current_A constant current load on phase A, specified as Amps
constant_current_A_reac constant current load on phase A, imaginary only, specified as Amps
constant_current_A_real constant current load on phase A, real only, specified as Amps
constant_current_AB constant current delta-connected load on phase A, specified as Amps
constant_current_AB_reac constant current delta-connected load on phase A, imaginary only, specified a...
constant_current_AB_real constant current delta-connected load on phase A, real only, specified as Amp...
constant_current_AN constant current wye-connected load on phase A, specified as Amps
constant_current_AN_reac constant current wye-connected load on phase A, imaginary only, specified as ...
constant_current_AN_real constant current wye-connected load on phase A, real only, specified as Amps
constant_current_B constant current load on phase B, specified as Amps
constant_current_B_reac constant current load on phase B, imaginary only, specified as Amps
constant_current_B_real constant current load on phase B, real only, specified as Amps
constant_current_BC constant current delta-connected load on phase B, specified as Amps
constant_current_BC_reac constant current delta-connected load on phase B, imaginary only, specified a...
constant_current_BC_real constant current delta-connected load on phase B, real only, specified as Amp...
constant_current_BN constant current wye-connected load on phase B, specified as Amps
constant_current_BN_reac constant current wye-connected load on phase B, imaginary only, specified as ...
constant_current_BN_real constant current wye-connected load on phase B, real only, specified as Amps
constant_current_C constant current load on phase C, specified as Amps
constant_current_C_reac constant current load on phase C, imaginary only, specified as Amps
constant_current_C_real constant current load on phase C, real only, specified as Amps
constant_current_CA constant current delta-connected load on phase C, specified as Amps
constant_current_CA_reac constant current delta-connected load on phase C, imaginary only, specified a...
constant_current_CA_real constant current delta-connected load on phase C, real only, specified as Amp...
constant_current_CN constant current wye-connected load on phase C, specified as Amps
constant_current_CN_reac constant current wye-connected load on phase C, imaginary only, specified as ...
constant_current_CN_real constant current wye-connected load on phase C, real only, specified as Amps
constant_impedance_1 constant impedance load on phase 1, specified as Ohms
constant_impedance_12 constant impedance load on phase 12, specified as Ohms
constant_impedance_12_reac constant impedance load on phase 12, imaginary only, specified as Ohms
constant_impedance_12_real constant impedance load on phase 12, real only, specified as Ohms
constant_impedance_1_reac constant impedance load on phase 1, imaginary only, specified as Ohms
constant_impedance_1_real constant impedance load on phase 1, real only, specified as Ohms
constant_impedance_2 constant impedance load on phase 2, specified as Ohms
constant_impedance_2_reac constant impedance load on phase 2, imaginary only, specified as Ohms
constant_impedance_2_real constant impedance load on phase 2, real only, specified as Ohms
constant_impedance_A constant impedance load on phase A, specified as Ohms
constant_impedance_A_reac constant impedance load on phase A, imaginary only, specified as Ohms
constant_impedance_A_real constant impedance load on phase A, real only, specified as Ohms
constant_impedance_AB constant impedance delta-connected load on phase A, specified as Ohms
constant_impedance_AB_reac constant impedance delta-connected load on phase A, imaginary only, specified...
constant_impedance_AB_real constant impedance delta-connected load on phase A, real only, specified as O...
constant_impedance_AN constant impedance wye-connected load on phase A, specified as Ohms
constant_impedance_AN_reac constant impedance wye-connected load on phase A, imaginary only, specified a...
constant_impedance_AN_real constant impedance wye-connected load on phase A, real only, specified as Ohm...
constant_impedance_B constant impedance load on phase B, specified as Ohms
constant_impedance_B_reac constant impedance load on phase B, imaginary only, specified as Ohms
constant_impedance_B_real constant impedance load on phase B, real only, specified as Ohms
constant_impedance_BC constant impedance delta-connected load on phase B, specified as Ohms
constant_impedance_BC_reac constant impedance delta-connected load on phase B, imaginary only, specified...
constant_impedance_BC_real constant impedance delta-connected load on phase B, real only, specified as O...
constant_impedance_BN constant impedance wye-connected load on phase B, specified as Ohms
constant_impedance_BN_reac constant impedance wye-connected load on phase B, imaginary only, specified a...
constant_impedance_BN_real constant impedance wye-connected load on phase B, real only, specified as Ohm...
constant_impedance_C constant impedance load on phase C, specified as Ohms
constant_impedance_C_reac constant impedance load on phase C, imaginary only, specified as Ohms
constant_impedance_C_real constant impedance load on phase C, real only, specified as Ohms
constant_impedance_CA constant impedance delta-connected load on phase C, specified as Ohms
constant_impedance_CA_reac constant impedance delta-connected load on phase C, imaginary only, specified...
constant_impedance_CA_real constant impedance delta-connected load on phase C, real only, specified as O...
constant_impedance_CN constant impedance wye-connected load on phase C, specified as Ohms
constant_impedance_CN_reac constant impedance wye-connected load on phase C, imaginary only, specified a...
constant_impedance_CN_real constant impedance wye-connected load on phase C, real only, specified as Ohm...
constant_power the constant power portion of the total load
constant_power_1 constant power load on split phase 1, specified as VA
constant_power_12 constant power load on split phase 12, specified as VA
constant_power_12_reac constant power load on phase 12, imaginary only, specified as VAr
constant_power_12_real constant power load on phase 12, real only, specified as W
constant_power_1_reac constant power load on phase 1, imaginary only, specified as VAr
constant_power_1_real constant power load on spit phase 1, real only, specified as W
constant_power_2 constant power load on split phase 2, specified as VA
constant_power_2_reac constant power load on phase 2, imaginary only, specified as VAr
constant_power_2_real constant power load on phase 2, real only, specified as W
constant_power_A constant power load on phase A, specified as VA
constant_power_A_reac constant power load on phase A, imaginary only, specified as VAr
constant_power_A_real constant power load on phase A, real only, specified as W
constant_power_AB constant power delta-connected load on phase A, specified as VA
constant_power_AB_reac constant power delta-connected load on phase A, imaginary only, specified as ...
constant_power_AB_real constant power delta-connected load on phase A, real only, specified as W
constant_power_AN constant power wye-connected load on phase A, specified as VA
constant_power_AN_reac constant power wye-connected load on phase A, imaginary only, specified as VA...
constant_power_AN_real constant power wye-connected load on phase A, real only, specified as W
constant_power_B constant power load on phase B, specified as VA
constant_power_B_reac constant power load on phase B, imaginary only, specified as VAr
constant_power_B_real constant power load on phase B, real only, specified as W
constant_power_BC constant power delta-connected load on phase B, specified as VA
constant_power_BC_reac constant power delta-connected load on phase B, imaginary only, specified as ...
constant_power_BC_real constant power delta-connected load on phase B, real only, specified as W
constant_power_BN constant power wye-connected load on phase B, specified as VA
constant_power_BN_reac constant power wye-connected load on phase B, imaginary only, specified as VA...
constant_power_BN_real constant power wye-connected load on phase B, real only, specified as W
constant_power_C constant power load on phase C, specified as VA
constant_power_C_reac constant power load on phase C, imaginary only, specified as VAr
constant_power_C_real constant power load on phase C, real only, specified as W
constant_power_CA constant power delta-connected load on phase C, specified as VA
constant_power_CA_reac constant power delta-connected load on phase C, imaginary only, specified as ...
constant_power_CA_real constant power delta-connected load on phase C, real only, specified as W
constant_power_CN constant power wye-connected load on phase C, specified as VA
constant_power_CN_reac constant power wye-connected load on phase C, imaginary only, specified as VA...
constant_power_CN_real constant power wye-connected load on phase C, real only, specified as W
contactor_close_Vmax pu voltage at which motor contactor recloses
contactor_open_Vmin pu voltage at which motor contactor opens
contactor_state the current status of the motor
continuous_rating_A Continuous rating for phase A of this link object (set individual line segmen...
continuous_rating_B Continuous rating for phase B of this link object (set individual line segmen...
continuous_rating_C Continuous rating for phase C of this link object (set individual line segmen...
control control operation strategy
Control Type of control used for regulating voltage
control_check
control_check1
control_check10
control_check11
control_check12
control_check2
control_check3
control_check4
control_check5
control_check6
control_check7
control_check8
control_check9
control_check_temp
control_level define bank or individual control
control_method IVVC activated or in standby
control_mode Inverter control mode: grid-forming or grid-following
control_mode_0
control_mode_1
control_mode_2
control_mode_3
control_power
controlled_dgs the group ID of the dg objects the controller controls
controlled_generation_unit The object reference/name of the controlled generation unit (i
controlling_period The user-defined period when both metrics are satisfied and this sync_ctrl ob...
controls_power CHECKPOINT_VAR: internal variable for controls power
controlTime CHECKPOINT_VAR: internal variable for controlTime
cooktop_check
cooktop_coil_setting_1
cooktop_coil_setting_2
cooktop_coil_setting_3
cooktop_energy_baseline
cooktop_energy_needed
cooktop_energy_used
cooktop_interval_setting_1
cooktop_interval_setting_2
cooktop_interval_setting_3
cooktop_run_prob
coolant_type coolant type, used in life time model
cooling_cap_curve Defines the function type to use for the adjusted cooling capacity as a funct...
cooling_COP system cooling performance coefficient
cooling_cop_curve Defines the function type to use for the adjusted cooling COP as a function o...
cooling_demand the current power draw to run the cooling system
cooling_design_temperature system cooling design temperature
cooling_setpoint thermostat cooling setpoint
cooling_supply_air_temp temperature of air blown out of the cooling system
cooling_system_type
cooling_type type of coolant fluid used in life time model
COP the cop of the fortran heat pump water heater model
COP_coeff
core_coil_weight The weight of the core and coil assembly in pounds
corrector_vals_Pref_ctrl CHECKPOINT_VAR: Corrector pass values of variables - Pref_ctrl
corrector_vals_Vset_ctrl CHECKPOINT_VAR: Corrector pass values of variables - Vset_ctrl
corrector_vals_Vset_ref CHECKPOINT_VAR: internal variable for corrector_vals
corrector_vals_w_measured CHECKPOINT_VAR: internal variable for corrector_vals
corrector_vals_wref_ctrl CHECKPOINT_VAR: internal variable for corrector_vals
corrector_vals_x CHECKPOINT_VAR: Corrector pass values of variables - x
corrector_vals_x_QV CHECKPOINT_VAR: internal variable for corrector_vals
count_coil_only CHECKPOINT_VAR: internal counter for coil only
count_control_only CHECKPOINT_VAR: internal counter for control only cycles
count_control_only1 CHECKPOINT_VAR: internal counter for control only cycles 1
count_motor_only CHECKPOINT_VAR: internal counter for motor only cycles
count_motor_only1 CHECKPOINT_VAR: internal counter for motor only cycles 1
count_motor_only_25 CHECKPOINT_VAR: internal counter for motor only 25
count_motor_only_68 CHECKPOINT_VAR: internal counter for motor only 68
Cp COP: Calculated coefficient of performance
Cp_max COP: Maximum coefficient of performance
Cp_rated COP: Rated coefficient of performance
CT_phase phase(s) monitored by CT
cumulative_heatgain the cumulative heatgain from the enduse to the parent
curr_VA_out_A AC power on A phase in three-phase system; 240-V connection on a triplex syst...
curr_VA_out_B AC power on B phase in three-phase system
curr_VA_out_C AC power on C phase in three-phase system
current_1 accumulator - used for debugging/interfacing only - current load on phase 1
current_12 accumulator - used for debugging/interfacing only - current load on phase 1 t...
current_2 accumulator - used for debugging/interfacing only - current load on phase 2
current_A bus current injection (in = positive), this an accumulator only, not a output...
current_AB bus current delta-connected injection (in = positive), this an accumulator on...
current_AN bus current wye-connected injection (in = positive), this an accumulator only...
current_B bus current injection (in = positive), this an accumulator only, not a output...
current_BC bus current delta-connected injection (in = positive), this an accumulator on...
current_BN bus current wye-connected injection (in = positive), this an accumulator only...
current_C bus current injection (in = positive), this an accumulator only, not a output...
current_CA bus current delta-connected injection (in = positive), this an accumulator on...
current_CN bus current wye-connected injection (in = positive), this an accumulator only...
current_convergence Convergence criterion for current changes on first timestep - basically initi...
current_convergence_criterion Max current magnitude update for grid-following inverters to return to QSTS, ...
current_deadband The deadband between current_set_high and current_set_low
current_deadband_center The current deadband center
current_fraction the fraction of total power that is constant current (pu)
current_fraction_1 this is the constant current fraction of base power on phase 1
current_fraction_12 this is the constant current fraction of base power on phase 12
current_fraction_2 this is the constant current fraction of base power on phase 2
current_fraction_A this is the constant current fraction of base power on phase A
current_fraction_B this is the constant current fraction of base power on phase B
current_fraction_C this is the constant current fraction of base power on phase C
current_in_A current flow to link (w
current_in_B current flow to link (w
current_in_C current flow to link (w
current_inj_A bus current injection (in = positive), but will not be rotated by powerflow f...
current_inj_B bus current injection (in = positive), but will not be rotated by powerflow f...
current_inj_C bus current injection (in = positive), but will not be rotated by powerflow f...
current_limit
current_N accumulator - used for debugging/interfacing only - current load on phase N
current_out_A current flow out of link (w
current_out_B current flow out of link (w
current_out_C current flow out of link (w
current_output_frequency VFD currently output frequency
current_pf power factor for constant current portion
current_pf_1 in similar format as ZIPload, this is the power factor of the phase 1 constan...
current_pf_12 in similar format as ZIPload, this is the power factor of the phase 12 consta...
current_pf_2 in similar format as ZIPload, this is the power factor of the phase 2 constan...
current_pf_A in similar format as ZIPload, this is the power factor of the phase A constan...
current_pf_B in similar format as ZIPload, this is the power factor of the phase B constan...
current_pf_C in similar format as ZIPload, this is the power factor of the phase C constan...
current_set_high low current set point for current control mode (turn off)
current_set_low high current set point for current control mode (turn on)
current_tank_status
current_transducer_ratio primary rating of current transformer
current_uptime Current time since last disconnect of node in minutes
currents
currTemp CHECKPOINT_VAR: internal variable for currTemp
curtailment lighting curtailment factor
customer_interrupted Reliability flag - goes active if the customer is in an 'interrupted' state
customer_interrupted_secondary Reliability flag - goes active if the customer is in an 'secondary interrupte...
cut_in_ws COP: Minimum wind speed for generator operation
cut_out_ws COP: Maximum wind speed for generator operation
CVR_enabled True if the CVR control is enabled in the exciter
CVR_Kd1 parameter of the second order transfer function for CVR control
CVR_Kd2 parameter of the second order transfer function for CVR control
CVR_Kd3 parameter of the second order transfer function for CVR control
CVR_kd_cvr parameter of the deviation control for CVR control
CVR_ki_cvr parameter of the integration control for CVR control
CVR_Kn1 parameter of the second order transfer function for CVR control
CVR_Kn2 parameter of the second order transfer function for CVR control
CVR_kp_cvr parameter of the proportional control for CVR control
CVR_kt_cvr parameter of the gain in feedback loop for CVR control
CVR_kw_cvr parameter of the gain in feedback loop for CVR control
CVR_mode First order control mode with feedback loop
CVR_PI True if the PI controller is implemented in CVR control
CVR_PID True if the PID controller is implemented in CVR control
cycle_duration CHECKPOINT_VAR: internal variable for cycle duration
cycle_duration_cooktop CHECKPOINT_VAR: internal variable for cycle duration cooktop
cycle_interval
cycle_length length of the combined on/off cycle between uses
cycle_time CHECKPOINT_VAR: internal variable for cycle time
cycle_time_cooktop CHECKPOINT_VAR: internal variable for cycle time cooktop
d
d_max Scaling constant for capacitor switching on - typically 0
d_min Scaling constant for capacitor switching off - typically 0
daily_dishwasher_demand
daily_door_opening
daily_dryer_demand
damping load setpoint to track to
data_file Path to
db_OF DELTAMODE: lower dead band for frequency-watt control, OF for over-frequency
db_OV DELTAMODE: dead band for volt-var control, OV for over-voltage
db_UF DELTAMODE: upper dead band for frequency-watt control, UF for under-frequency
db_UV DELTAMODE: dead band for volt-var control, UV for under-voltage
deadband percentage deadband
default_current_variable Accumulator/placeholder for default current value, when solar is run without ...
default_power_variable Accumulator/placeholder for default power value, when solar is run without an...
default_voltage_variable Accumulator/placeholder for default voltage value, when solar is run without ...
defaults CHECKPOINT_VAR: internal variable for appliance default object
defrost_criterion
defrost_energy
defrost_power
defrostDelayed
DEGOV1_K Governor actuator gain
DEGOV1_R Governor droop constant (p
DEGOV1_T1 Governor electric control box time constant (s)
DEGOV1_T2 Governor electric control box time constant (s)
DEGOV1_T3 Governor electric control box time constant (s)
DEGOV1_T4 Governor actuator time constant (s)
DEGOV1_T5 Governor actuator time constant (s)
DEGOV1_T6 Governor actuator time constant (s)
DEGOV1_TD Governor combustion delay (s)
DEGOV1_throttle Governor throttle state variable
DEGOV1_TMAX Governor actuator upper limit (p
DEGOV1_TMIN Governor actuator lower limit (p
DEGOV1_x1 Governor electric box state variable
DEGOV1_x2 Governor electric box state variable
DEGOV1_x4 Governor electric box state variable
DEGOV1_x5 Governor electric box state variable
DEGOV1_x6 Governor electric box state variable
delay_defrost_time
delay_time
delta_epA DELTAMODE: The change in real current error for phase A or triplex phase
delta_epB DELTAMODE: The change in real current error for phase B
delta_epC DELTAMODE: The change in real current error for phase C
delta_eqA DELTAMODE: The change in reactive current error for phase A or triplex phase
delta_eqB DELTAMODE: The change in reactive current error for phase B
delta_eqC DELTAMODE: The change in reactive current error for phase C
delta_f_val Frequency change value for compressor sensitivities
delta_mdA DELTAMODE: The change in d-axis current modulation for phase A or triplex pha...
delta_mdB DELTAMODE: The change in d-axis current modulation for phase B
delta_mdC DELTAMODE: The change in d-axis current modulation for phase C
delta_mode_rotor_speed_exit percentage speed of nominal to exit delta mode
delta_mode_rotor_speed_trigger percentage speed of nominal when delta mode is triggered
delta_mode_voltage_exit percentage voltage of nominal to exit delta mode
delta_mode_voltage_trigger percentage voltage of nominal when delta mode is triggered
delta_mqA DELTAMODE: The change in q-axis current modulation for phase A or triplex pha...
delta_mqB DELTAMODE: The change in q-axis current modulation for phase B
delta_mqC DELTAMODE: The change in q-axis current modulation for phase C
delta_trigger_mult multiplier against voltage and frequency tolerances to trigger/maintain delta...
delta_V frequency regulation output
delta_Vmax upper limit of the frequency regulation output
delta_Vmin lower limit of the frequency regulation output
delta_w_droop DELTAMODE: delta omega fro p-f droop
deltamode_full_Y_all_matrix deltamode-functionality full_Y_all matrix exposes so generator objects can in...
deltamode_full_Y_matrix deltamode-functionality full_Y matrix exposes so generator objects can intera...
deltamode_generator_current_12 deltamode-functionality - bus current injection (in = positive), direct gener...
deltamode_generator_current_A deltamode-functionality - bus current injection (in = positive), direct gener...
deltamode_generator_current_B deltamode-functionality - bus current injection (in = positive), direct gener...
deltamode_generator_current_C deltamode-functionality - bus current injection (in = positive), direct gener...
deltamode_inclusive CHECKPOINT_VAR: Boolean for deltamode calls - pulled from object flags
deltamode_only_changes Flag to prevent reinitialization of dynamic equations - implies all changes a...
deltamode_PGenTotal deltamode-functionality - power value for a diesel generator -- accumulator o...
deltamode_registered CHECKPOINT_VAR: internal variable for deltamode registration status
demand the amount of laundry accumulating daily
demand_cooktop number of loads accumulating daily
demand_oven number of loads accumulating daily
demand_profile
demand_rate consumer demand rate that prematurely turns on a device or population
demand_response_mode Activates equilibrium dynamic representation of demand response
derating Panel derating to account for manufacturing variances
design_cooling_capacity system cooling capacity
design_cooling_setpoint system design cooling setpoint
design_heating_capacity system heating capacity
design_heating_setpoint system design heating setpoint
design_internal_gain_density average density of heat generating devices in the house
design_internal_gains system design internal gains
design_peak_solar system design solar load
desired_charge_rate Current desired charge rate of the vehicle
desired_motor_speed Desired speed of the VFD In ROM
desired_motor_state Should the motor be on or off
desired_output_frequency VFD desired output frequency based on the desired RPM
desired_pf Desired power-factor magnitude at the substation transformer or regulator
desired_voltages Desired operating voltages for the regulators, separated by commas
diameter Diameter of line for capacitance calculations
disable_volt_var_if_no_input_power
discharge_lockout_time FOUR QUADRANT MODEL: Lockout time when a discharging operation occurs before ...
discharge_off_threshold FOUR QUADRANT MODEL: power level at which the inverter should cease dischargi...
discharge_on_threshold FOUR QUADRANT MODEL: power level at which the inverter should try discharging...
discharge_pf installed pump power factor
discharge_power installed pump power usage
discharge_rate rating of discharge or cooling
discharge_schedule_type Scheduling method for discharging
discharge_threshold FOUR QUADRANT MODEL: Level at which all inverters in the group will begin dis...
discharge_time Flag indicating if discharging is available at the current time (1 or 0)
discrete_step_size MULTILAYER MODEL: The step size in seconds to use in the discrete tank temper...
dishwasher_coil_power_1
dishwasher_coil_power_2
dishwasher_coil_power_3
dishwasher_demand
dishwasher_run_prob
distance_AB
distance_AC
distance_AE distance between phase A wire and earth
distance_AN
distance_BC
distance_BE distance between phase B wire and earth
distance_BN
distance_CE distance between phase C wire and earth
distance_CN
distance_NE distance between neutral wire and earth
distribution_current_A
distribution_current_B
distribution_current_C
distribution_load The total load of all three phases at the substation object
distribution_power_A
distribution_power_B
distribution_power_C
distribution_real_energy
distribution_voltage_A
distribution_voltage_AB
distribution_voltage_B
distribution_voltage_BC
distribution_voltage_C
distribution_voltage_CA
dlc_offset used as a cap to offset the thermostat deadband for direct load control appli...
DO_Thershold
DOA_NR_ITERATIONS Set the degree of accuracy of newton-raphson method
door_energy_calc CHECKPOINT_VAR: internal variable for door energy calculation
door_next_open_time CHECKPOINT_VAR: internal variable for door next open time
door_open CHECKPOINT_VAR: internal variable for door open
door_opening_criterion
door_opening_energy
door_opening_power
door_return_time CHECKPOINT_VAR: internal variable for door return time
door_time CHECKPOINT_VAR: internal variable for door time
door_to_open CHECKPOINT_VAR: internal variable for door to open
dr_mode_double
dr_signal the on/off signal to send to the fortran waterheater model
dryer_check
dryer_coil_power
dryer_on
dryer_ready
dryer_run_prob
dryer_turn_on
dT_coeff Temperature difference coefficient for module temperature correction formula
dTair
duct_pressure_drop end-to-end pressure drop for the ventilation ducts, in inches of water
dump_house_initialization_parameters bool to dump the house initialization parameters to _param...
duration_at_home Duration the vehicle remains at home
duration_at_work Duration the vehicle remains at work
durations
duty_cycle fraction of time in the on state
dwell_time Time for system to remain constant before a state change will be passed
dynamic_model_mode DELTAMODE: Underlying model to use for deltamode control
E0_ES_pu Battery constant voltage, per unit
e_droop_A DELTAMODE: Internal voltage of given by the grid-forming droop controller, ph...
e_droop_A_PU DELTAMODE: Internal voltage of given by the grid-forming droop controller, ph...
e_droop_angle_A DELTAMODE: Internal angle given by the droop controller, phase A
e_droop_angle_B DELTAMODE: Internal angle given by the droop controller, phase B
e_droop_angle_C DELTAMODE: Internal angle given by the droop controller, phase C
e_droop_B DELTAMODE: Internal voltage of given by the grid-forming droop controller, ph...
e_droop_B_PU DELTAMODE: Internal voltage of given by the grid-forming droop controller, ph...
e_droop_C DELTAMODE: Internal voltage of given by the grid-forming droop controller, ph...
e_droop_C_PU DELTAMODE: Internal voltage of given by the grid-forming droop controller, ph...
E_ES_pu No-load voltage, per unit
E_mag DELTAMODE: magnitude of internal voltage of grid-forming inverter
E_Max LEGACY MODEL: the maximum capacity of the battery
E_max DELTAMODE: E_max and E_min are the maximum and minimum of the output of volta...
E_min DELTAMODE: E_max and E_min are the maximum and minimum of the output of volta...
E_Next CHECKPOINT_VAR: internal variable for E_Next
e_source_A DELTAMODE: Internal voltage of grid-forming source, phase A
e_source_A_PU DELTAMODE: Actual internal voltage of grid-forming source, per unit, phase A
e_source_B DELTAMODE: Internal voltage of grid-forming source, phase B
e_source_B_PU DELTAMODE: Actual internal voltage of grid-forming source, per unit, phase B
e_source_C DELTAMODE: Internal voltage of grid-forming source, phase C
e_source_C_PU DELTAMODE: Actual internal voltage of grid-forming source, per unit, phase C
east_incident_solar_radiation incident solar radiation hitting the east side of the house
ed_pu_A DELTAMODE: Internal voltage of grid-following inverter, d-axis, phase A
ed_pu_B DELTAMODE: Internal voltage of grid-following inverter, d-axis, phase B
ed_pu_C DELTAMODE: Internal voltage of grid-following inverter, d-axis, phase C
EfA COP: Synchronous generator induced voltage on phase A
EfB COP: Synchronous generator induced voltage on phase B
EfC COP: Synchronous generator induced voltage on phase C
efficiency Current VFD efficiency based on the load/VFD output Horsepower
efficiency_value Exposed variable - hidden for solar
Eint_A Unrotated, unsequenced phase A internal voltage
Eint_B Unrotated, unsequenced phase B internal voltage
Eint_C Unrotated, unsequenced phase C internal voltage
electrical_power motor power
electrical_torque electrical torque
EMAX Exciter upper limit (p
Emax DELTAMODE: E_max and E_min are the maximum and minimum of the output of volta...
emergency_rating_A Emergency rating for phase A of this link object (set individual line segment...
emergency_rating_B Emergency rating for phase B of this link object (set individual line segment...
emergency_rating_C Emergency rating for phase C of this link object (set individual line segment...
EMIN Exciter lower limit (p
Emin DELTAMODE: E_max and E_min are the maximum and minimum of the output of volta...
enable_1547_checks DELTAMODE: Enable IEEE 1547-2003 disconnect checking
enable_J2894 Enable SAE J2894-suggested voltage and ramping suggestions
enable_ramp_rates_reactive DELTAMODE: Boolean used to indicate whether inverter ramp rate is enforced or...
enable_ramp_rates_real DELTAMODE: Boolean used to indicate whether inverter ramp rate is enforced or...
Energy LEGACY MODEL: the available capacity of the battery
energy the total energy consumed since the last meter reading
energy_baseline
energy_meter
energy_needed
energy_used
envelope_UA overall UA of the home's envelope
epA DELTAMODE: The real current error for phase A or triplex phase
epB DELTAMODE: The real current error for phase B
epC DELTAMODE: The real current error for phase C
EpRotated d-q rotated E-prime internal voltage state variable
eq_pu_A DELTAMODE: Internal voltage of grid-following inverter, q-axis, phase A
eq_pu_B DELTAMODE: Internal voltage of grid-following inverter, q-axis, phase B
eq_pu_C DELTAMODE: Internal voltage of grid-following inverter, q-axis, phase C
eqA DELTAMODE: The reactive current error for phase A or triplex phase
eqB DELTAMODE: The reactive current error for phase B
eqC DELTAMODE: The reactive current error for phase C
event_deltat CHECKPOINT_VAR: Event-driven delta-t variable
event_temp
eventgen_object Link to generic eventgen object to handle unexpected faults
excess_input_power FOUR QUADRANT MODEL: Excess power at the input of the inverter that is otherw...
Exciter_Q_constant_ki parameter of the integration control for constant Q mode
Exciter_Q_constant_kp parameter of the propotional control for constant Q mode
Exciter_Q_constant_Qref Qref input to AVR controls (per-unit), if supported
Exciter_type Simplified Excitation System
exterior_ceiling_fraction ratio of external ceiling sf to floor area
exterior_floor_fraction ratio of floor area used in UA calculation
exterior_wall_fraction ratio of exterior wall area to total wall area
external_motor_attached Flag to indicate an external powerflow:motor is being used
external_pf_mode set up for using ONE or TWO external_v1N and v2N from another powerflow solve...
external_v1N circuit 1N voltage from external power flow
external_v2N circuit 2N voltage from external power flow
F_current DELTAMODE: feed forward term gain in current loop
f_db_max frequency dead band max
f_db_min frequency dead band max
f_PLL_A DELTAMODE: frequency of terminal voltage measured by PLL, phase A
f_PLL_B DELTAMODE: frequency of terminal voltage measured by PLL, phase B
f_PLL_C DELTAMODE: frequency of terminal voltage measured by PLL, phase C
fan_current_fraction Current component of fan ZIP load
fan_design_airflow designed airflow for the ventilation system
fan_design_power designed maximum power draw of the ventilation fan
fan_heatgain_fraction CHECKPOINT_VAR: internal variable for fan heatgain fraction in pu
fan_impedance_fraction Impedance component of fan ZIP load
fan_low_power_fraction fraction of ventilation fan power draw during low-power mode (two-speed only)
fan_power current ventilation fan power draw
fan_power_factor Power factor of the fan load
fan_power_fraction Power component of fan ZIP load
fan_type
fault_current_in_A fault current flowing in, phase A
fault_current_in_B fault current flowing in, phase B
fault_current_in_C fault current flowing in, phase C
fault_current_out_A fault current flowing out, phase A
fault_current_out_B fault current flowing out, phase B
fault_current_out_C fault current flowing out, phase C
fault_voltage_A fault voltage, phase A
fault_voltage_B fault voltage, phase B
fault_voltage_C fault voltage, phase C
faulted_section Faulted section for reconfiguration
feedback the feedback signal, for reference purposes
feeder_power_limit Comma-separated power limit (VA) for feeders during reconfiguration
feeder_power_links Comma-separated list of link-based objects for monitoring power through
feeder_vertex_list Comma-separated object list that defines the feeder vertices
feederhead_meter the name of the meter
FF_Door_Openings
field_voltage machine field voltage state variable
file the file to dump the voltage data into
filename the file to dump the voltage data into
filename_dump_reliability the file to dump the current data into
filename_dump_system the file to dump the current data into
filetype The tape's type (the file's extension by default)
first_iter_counter CHECKPOINT_VAR: internal variable for first_iter_counter
first_iteration_current_injection CHECKPOINT_VAR: Initialization variable - mostly so SWING_PQ buses initalize ...
first_pass CHECKPOINT_VAR: internal variable for first pass
first_run CHECKPOINT_VAR: internal variable for first_run
first_sync_delta_enabled CHECKPOINT_VAR: internal variable for first_sync_delta_enabled
first_tier_energy switching point between base price and first tier price
first_tier_price price of electricity between first tier and second tier energy usage
first_time_step CHECKPOINT_VAR: internal variable for first_time_step
flag_switchOn CHECKPOINT_VAR: internal variable for flag_switchOn
flags Core object flags
floor_area home conditioned floor area
flow_direction flag used for describing direction of the flow of power
flux1d machine transient flux on d-axis state variable
flux2q machine subtransient flux on q-axis state variable
food_density food density
fortran_sim_time the amount of time the fortran model should simulate
four_quadrant_control_mode FOUR QUADRANT MODEL: Activates various control modes
freq DELTAMODE: the frequency obtained from the P-f droop controller
freq_diff_hz Measurement property: frequency difference in Hz
freq_diff_noabs_hz Measurement property: frequency difference in Hz without abs()
freq_pwr_sched
frequency_convergence_criterion Max frequency update for grid-forming inverters to return to QSTS
frequency_deviation Frequency deviation of diesel_dg
frequency_deviation_energy Frequency deviation accumulation of diesel_dg
frequency_deviation_max Frequency deviation of diesel_dg
frequency_high The high frequency that activates the controller
frequency_low The low frequency that activates the controller
frequency_measure_type PLL frequency measurement
frequency_open_loop_control DELTAMODE: Boolean value indicating whether the frequency open loop control o...
frequency_regulation DELTAMODE: Boolean value indicating whether the frequency regulation of the s...
frequency_tolerance tolerance for checking the frequency metric
frequency_tolerance_lb_hz The user-specified tolerance in Hz for checking the lower bound of the freque...
frequency_tolerance_ub_hz The user-specified tolerance in Hz for checking the upper bound of the freque...
frequency_watt DELTAMODE: Boolean used to indicate whether inverter f/p droop is included or...
frequency_watt_droop DELTAMODE: p-f droop gain in frequency-watt
from_node from_node - source node
fset fset input to governor controls (Hz) - takes priority over wref
fuelEmissionCal Boolean value indicating whether fuel and emission calculations are used or n...
FuelUse Total fuel usage (gal) based on kW power output
full_load_loss Another method of specifying transformer impedances, defined as per unit powe...
full_output_file Flag to indicate if the output_filename report contains both supported and un...
full_scale magnitude of the load at full load, used for feed-forward control
fuse_resistance The resistance value of the fuse when it is not blown
gain Gain of the controller
gain_QV Gain of the controller for secondary voltage control
gas_fan_power load of a running gas waterheater
gas_standby_power load of a gas waterheater in standby
GAST_AT Governor Ambient Temperature load limit (units)
GAST_KT Governor temperature control loop gain
GAST_R Governor droop constant (p
GAST_T1 Governor electric control box time constant (s)
GAST_T2 Governor electric control box time constant (s)
GAST_T3 Governor temperature limiter time constant (s)
GAST_throttle Governor throttle state variable
GAST_VMAX Governor actuator upper limit (p
GAST_VMIN Governor actuator lower limit (p
GAST_x1 Governor electric box state variable
GAST_x2 Governor electric box state variable
GAST_x3 Governor electric box state variable
Gen_mode COP: Maintains the real and reactive output at the terminals - currently unsu...
Gen_status COP: Generator is currently available to supply power
Gen_type Dynamics-capable implementation of synchronous diesel generator
GenElecEff COP: Calculated generator electrical efficiency
generate_all_scenarios Flag to determine if restoration reconfiguration and continues, or explores t...
generator_dynamic Flag to indicate a voltage-sourcing or swing-type generator is present -- use...
generator_efficiency COP: Calculated generator electrical efficiency
generator_mode LEGACY MODEL: Selects generator control mode when using legacy model; in non-...
generator_status describes whether the generator is online or offline
GENTLE_PREWASH_ENERGY
GENTLE_PREWASH_POWER
GENTLE_SMALLWASH_ENERGY
GENTLE_SMALLWASH_POWER
GENTLE_SPIN_HIGH_ENERGY
GENTLE_SPIN_HIGH_POWER
GENTLE_SPIN_LOW_ENERGY
GENTLE_SPIN_LOW_POWER
GENTLE_SPIN_MEDIUM_ENERGY
GENTLE_SPIN_MEDIUM_POWER
GENTLE_WASH_ENERGY
GENTLE_WASH_POWER
geometric_mean_radius radius of the conductor
Geothermal_CO2
Geothermal_Conv_Eff
Geothermal_emissions_CO2
Geothermal_emissions_NOx
Geothermal_emissions_SO2
Geothermal_Max_Out
Geothermal_NOx
Geothermal_Order
Geothermal_Out
Geothermal_SO2
GFA_enable Disable/Enable Grid Friendly Appliance(TM)-type functionality
GFA_freq_disconnect_time Frequency violation disconnect time for Grid Friendly Appliance(TM)-type func...
GFA_freq_high_trip High frequency trip point for Grid Friendly Appliance(TM)-type functionality
GFA_freq_low_trip Low frequency trip point for Grid Friendly Appliance(TM)-type functionality
GFA_reconnect_time Reconnect time for Grid Friendly Appliance(TM)-type functionality
GFA_status Grid Friendly Appliance(TM)-type functionality - whether it is in service (no...
GFA_trip_method GFA trip for over-voltage
GFA_volt_disconnect_time Voltage violation disconnect time for Grid Friendly Appliance(TM)-type functi...
GFA_volt_high_trip High voltage trip point for Grid Friendly Appliance(TM)-type functionality
GFA_volt_low_trip Low voltage trip point for Grid Friendly Appliance(TM)-type functionality
GGOV1_Acceleration_Limit_enable Enables/disables acceleration limiter (fsra) of low-value-select
GGOV1_aset Acceleration limiter setpoint, p
GGOV1_db Speed governor dead band
GGOV1_Dm Speed sensitivity coefficient, p
GGOV1_err2
GGOV1_err2a
GGOV1_err3
GGOV1_err4
GGOV1_err7
GGOV1_fset fset input to governor controls (Hz) - takes priority over wref
GGOV1_fsra Acceleration limiter block input to low-value-select
GGOV1_fsrn PID block input to low-value-select
GGOV1_fsrt Load limiter block input to low-value-select
GGOV1_fsrtNoLim
GGOV1_Fuel_lag Switch for fuel source characteristic, = 0 for fuel flow independent of speed...
GGOV1_FuelFlow
GGOV1_GovOutPut
GGOV1_Ka Acceleration limiter Gain
GGOV1_Kdgov Governor derivative gain
GGOV1_Kigov Governor integral gain
GGOV1_Kiload Load limiter integral gain for PI controller
GGOV1_Kimw Power controller (reset) gain
GGOV1_Kpgov Governor proportional gain
GGOV1_Kpload Load limiter proportional gain for PI controller
GGOV1_Kturb Turbine gain (>0
GGOV1_Ldref Load limiter reference value p
GGOV1_Load_Limit_enable Enables/disables load limiter (fsrt) of low-value-select
GGOV1_LowValSelect
GGOV1_LowValSelect1
GGOV1_maxerr Maximum value for speed error signal
GGOV1_minerr Minimum value for speed error signal
GGOV1_PID_enable Enables/disables PID controller (fsrn) of low-value-select
GGOV1_Pmwset Power controller setpoint, MW
GGOV1_Pset GGOV1_Pset input to governor controls (per-unit), if supported
GGOV1_R Permanent droop, p
GGOV1_rclose Minimum valve closing rate, p
GGOV1_ropen Maximum valve opening rate, p
GGOV1_Rselect Feedback signal for droop, = 1 selected electrical power, = 0 none (isochrono...
GGOV1_RselectValue
GGOV1_speed_error Speed difference in per-unit for input to PID controller
GGOV1_Ta Acceleration limiter time constant, sec
GGOV1_Tact Actuator time constant
GGOV1_Tb Turbine lag time constant, sec
GGOV1_Tc Turbine lead time constant, sec
GGOV1_Tdgov Governor derivative controller time constant, sec
GGOV1_Teng Transport lag time constant for diesel engine
GGOV1_Tfload Load Limiter time constant, sec
GGOV1_Tpelec Electrical power transducer time constant, sec
GGOV1_Tsa Temperature detection lead time constant, sec
GGOV1_Tsb Temperature detection lag time constant, sec
GGOV1_ValveStroke
GGOV1_vmax Maximum valve position limit
GGOV1_vmin Minimum valve position limit
GGOV1_wfnl No load fuel flow, p
GGOV1_x1
GGOV1_x10
GGOV1_x10a
GGOV1_x10b
GGOV1_x2
GGOV1_x2a
GGOV1_x3
GGOV1_x3a
GGOV1_x4
GGOV1_x4a
GGOV1_x4b
GGOV1_x5
GGOV1_x5a
GGOV1_x5b
GGOV1_x6
GGOV1_x7
GGOV1_x7a
GGOV1_x8
GGOV1_x8a
GGOV1_x9
GGOV1_x9a
glass_type glass used in the windows
glazing_layers number of layers of glass in each window
glazing_shgc siding glazing solar heat gain coeffient
glazing_treatment the treatment to increase the reflectivity of the exterior windows
glob_min_timestep CHECKPOINT_VAR: internal variable for global minimum timestep
glob_min_timestep_dbl CHECKPOINT_VAR: internal variable for global minimum timestep in double forma...
Governor_type P_CONSTANT mode Governor Model
grid_association Flag to indicate if multiple, distinct grids are allowed in a GLM, or if anyt...
grid_following_mode grid-following mode, positive sequency or balanced three phase power
grid_forming_mode grid-forming mode, CONSTANT_DC_BUS or DYNAMIC_DC_BUS
grid_frequency CHECKPOINT_VAR: internal variable for grid frequency
gross_wall_area gross outdoor wall area
group the group ID to output data for (all nodes if empty)
group_max_charge_rate FOUR QUADRANT MODEL: Sum of the charge rates of the batteries involved in the...
group_max_discharge_rate FOUR QUADRANT MODEL: Sum of the discharge rates of the batteries involved in ...
group_rated_power FOUR QUADRANT MODEL: Sum of the inverter power ratings of the inverters invol...
groupid Free-text group label
groupid_dg the group ID of the dg objects the controller controls
H inertia constant
hc_mode
heat_cool_gain system heat gains(losses)
heat_fraction fraction of ZIPload that is transferred as heat
heat_mode
heat_needed
heat_pump_coefficient_of_performance current COP of the water heater pump - currently calculated internally and no...
heateddry_check1
heateddry_check2
Heateddry_option_check
heatgain the heat transferred from the enduse to the parent
heatgain_fraction the fraction of the heat that goes to the parent (pu)
heatgain_only allows the zipload to generate heat only (no kW), not activated by default
heatgain_per_person
heatgains
heating_cap_curve Defines the function type to use for the adjusted heating capacity as a funct...
heating_COP system heating performance coefficient
heating_cop_curve Defines the function type to use for the adjusted heating COP as a function o...
heating_demand the current power draw to run the heating system
heating_design_temperature system heating design temperature
heating_element_capacity the power of the heating element
heating_element_on CHECKPOINT_VAR: internal variable for heating element on
heating_setpoint thermostat heating setpoint
heating_supply_air_temp temperature of air blown out of the heating system
heating_system_type
heatpump_predicted_energy Amount of energy heat pump predicts to need to reach setpoint - energy increa...
height the height of the oven
high_load_deadband High loading case voltage deadband for each regulator, separated by commas
high_temperature LEGACY MODEL: high temperature of linear control; defines slope
horizontal_diffuse_solar_radiation incident solar radiation hitting the top of the house
hourly_door_opening CHECKPOINT_VAR: internal variable for hourly door opening
house_present boolean for detecting whether a house is attached, not an input
house_thermal_mass thermal mass of the house's contained mass
houseload
hvac_breaker_rating determines the amount of current the HVAC circuit breaker can handle
hvac_duty_cycle
hvac_last_off
hvac_last_on
hvac_load heating/cooling system load
hvac_motor_efficiency when using motor model, percent efficiency of hvac motor
hvac_motor_loss_power_factor when using motor model, power factor of motor losses
hvac_period_length
hvac_period_off CHECKPOINT_VAR: internal variable for hvac period off (minutes)
hvac_period_on CHECKPOINT_VAR: internal variable for hvac period on (minutes)
hvac_power describes hvac load complex power consumption
hvac_power_factor power factor of hvac
Hydroelectric_CO2
Hydroelectric_Conv_Eff
Hydroelectric_emissions_CO2
Hydroelectric_emissions_NOx
Hydroelectric_emissions_SO2
Hydroelectric_Max_Out
Hydroelectric_NOx
Hydroelectric_Order
Hydroelectric_Out
Hydroelectric_SO2
I_ES_pu ES output current, per unit
I_In LEGACY MODEL: the current flowing into the battery of the battery
I_Internal LEGACY MODEL: the internal current of the battery
I_M Peak magnetization current at rated voltage of the saturation curve
I_Max LEGACY MODEL: the maximum current output of the battery
I_Out LEGACY MODEL: the AC current output of the battery
I_Prev LEGACY MODEL: the previous current output of the battery
Ia
Ia_H
IA_Out_PU_temp Phase A current for current limiting calculation of a grid-forming inverter,...
Ia_R
Ia_S
Ia_T
Ia_W
Iapu CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi...
Ias motor phase-a stator current
Ib backward current
IB_Out_PU_temp Phase B current for current limiting calculation of a grid-forming inverter,...
Ibpu CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi...
Ibs motor phase-b stator current
IC_Out_PU_temp Phase C current for current limiting calculation of a grid-forming inverter,...
ice_making_probability
icemaker_running
icemaking_energy
icemaking_power
Icpu CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi...
Ics motor phase-c stator current
IdqA DELTAMODE: The dq-axis current for phase A or triplex phase
IdqB DELTAMODE: The dq-axis current for phase B
IdqC DELTAMODE: The dq-axis current for phase C
Ids time before tripped motor reconnects
IEEE_1547_STATUS CHECKPOINT_VAR: internal variable for ieee_1547_version
IEEE_1547_trip_method High over-voltage level trip
IEEE_1547_version DELTAMODE: Version of IEEE 1547 to use to populate defaults
If forward current
igd_pu_A DELTAMODE: terminal current of grid-following inverter, d-axis, phase A
igd_pu_A_filter DELTAMODE: terminal current of grid-following inverter, d-axis, phase A, curr...
igd_pu_B DELTAMODE: terminal current of grid-following inverter, d-axis, phase B
igd_pu_B_filter DELTAMODE: terminal current of grid-following inverter, d-axis, phase B, curr...
igd_pu_C DELTAMODE: terminal current of grid-following inverter, d-axis, phase C
igd_pu_C_filter DELTAMODE: terminal current of grid-following inverter, d-axis, phase C, curr...
igd_ref_A DELTAMODE: reference current of grid-following inverter, d-axis, phase A
igd_ref_B DELTAMODE: reference current of grid-following inverter, d-axis, phase B
igd_ref_C DELTAMODE: reference current of grid-following inverter, d-axis, phase C
igd_ref_max DELTAMODE: Upper limit of igd_ref of grid-following inverter, d-axis
igd_ref_min DELTAMODE: Lower limit of igd_ref of grid-following inverter, d-axis
igq_pu_A DELTAMODE: terminal current of grid-following inverter, q-axis, phase A
igq_pu_A_filter DELTAMODE: terminal current of grid-following inverter, q-axis, phase A, curr...
igq_pu_B DELTAMODE: terminal current of grid-following inverter, q-axis, phase B
igq_pu_B_filter DELTAMODE: terminal current of grid-following inverter, q-axis, phase B, curr...
igq_pu_C DELTAMODE: terminal current of grid-following inverter, q-axis, phase C
igq_pu_C_filter DELTAMODE: terminal current of grid-following inverter, q-axis, phase C, curr...
igq_ref_A DELTAMODE: reference current of grid-following inverter, q-axis, phase A
igq_ref_B DELTAMODE: reference current of grid-following inverter, q-axis, phase B
igq_ref_C DELTAMODE: reference current of grid-following inverter, q-axis, phase C
igq_ref_max DELTAMODE: Upper limit of igq_ref of grid-following inverter, q-axis
igq_ref_min DELTAMODE: Lower limit of igq_ref of grid-following inverter, q-axis
Im
Im_H
Im_R
Im_S
Im_T
Im_W
imag Imaginary component
Imax DELTAMODE: the maximum current of a grid-forming inverter
impedance Series impedance, pu
impedance1 Secondary series impedance (only used when you want to define each individual...
impedance2 Secondary series impedance (only used when you want to define each individual...
impedance_fraction the fraction of total power that is constant impedance (pu)
impedance_fraction_1 this is the constant impedance fraction of base power on phase 1
impedance_fraction_12 this is the constant impedance fraction of base power on phase 12
impedance_fraction_2 this is the constant impedance fraction of base power on phase 2
impedance_fraction_A this is the constant impedance fraction of base power on phase A
impedance_fraction_B this is the constant impedance fraction of base power on phase B
impedance_fraction_C this is the constant impedance fraction of base power on phase C
impedance_pf power factor for constant impedance portion
impedance_pf_1 in similar format as ZIPload, this is the power factor of the phase 1 constan...
impedance_pf_12 in similar format as ZIPload, this is the power factor of the phase 12 consta...
impedance_pf_2 in similar format as ZIPload, this is the power factor of the phase 2 constan...
impedance_pf_A in similar format as ZIPload, this is the power factor of the phase A constan...
impedance_pf_B in similar format as ZIPload, this is the power factor of the phase B constan...
impedance_pf_C in similar format as ZIPload, this is the power factor of the phase C constan...
impedances
in_svc Timestamp the object enters service
incident_solar_radiation average incident solar radiation hitting the house
include_fan_heatgain Boolean to choose whether to include the heat generated by the fan in the ETP...
include_solar_quadrant bit set for determining which solar incidence quadrants should be included in...
indiv_measured_power_1 current measured power on phase 1
indiv_measured_power_12 current measured power on phase 12
indiv_measured_power_2 current measured power on phase 2
indiv_measured_power_N metered power, phase N
inertia Inertial constant (H) of generator
init_tank_temp CHECKPOINT_VAR: internal variable for initial tank temperature
inlet_food_temperature the inlet temperature of the food
inlet_water_temperature the inlet temperature of the water tank
input_humid
input_rain
input_solar
input_temp
input_wind
Inr_cj conjugate of negative sequence rotor current
inrush_convergence_value Tolerance, as change in line voltage drop between iterations, for deltamode i...
inrush_integration_method Integration method for in-rush
inrush_integration_method_capacitance Selected integration method to use for capacitive elements of the link
inrush_integration_method_inductance Selected integration method to use for inductive elements of the link
inrush_saturation_enabled flag to include saturation effects during inrush calculations
Ins_cj conjugate of negative sequence stator current
Insolation
install_type Defines location of the transformer installation
installed_insulation_life the normal lifetime of the transformer insulation at rated load, hours
installed_power installed lighting capacity
insulation_relative_permitivitty Permitivitty of insulation, relative to air
insulation_thickness thickness of insulation around cabling
interior_exterior_wall_ratio ratio of interior to exterior walls
interior_surface_heat_transfer_coeff
internal_battery_load CHECKPOINT_VAR: the power out of the battery on the source side of the intern...
internal_gain internal heat gains
internal_model_current_convergence Convergence value for internal current calculations
inverter_1547_status DELTAMODE: Indicator if the inverter is curtailed due to a 1547 violation or ...
inverter_convergence_criterion The maximum change in error threshold for exitting deltamode
inverter_droop_fp DELTAMODE: Boolean used to indicate whether inverter f/p droop is included or...
inverter_droop_vq DELTAMODE: Boolean used to indicate whether inverter q/v droop is included or...
inverter_efficiency FOUR QUADRANT MODEL: The efficiency of the inverter
inverter_first_step CHECKPOINT_VAR: internal variable for inverter_first_step
inverter_manufacturer MULTIPOINT EFFICIENCY MODEL: the manufacturer of the inverter to setup up pre...
inverter_type LEGACY MODEL: Sets efficiencies and other parameters; if using four_quadrant_...
Ipr positive sequence rotor current
Ips positive sequence stator current
Iqs time before tripped motor reconnects
Irotated d-q rotated sequence current state variable
Irotor_A COP: Induction generator induced current on phase A in p
Irotor_B COP: Induction generator induced current on phase B in p
Irotor_C COP: Induction generator induced current on phase C in p
Is motor current
is_240 load is 220/240 V (across both phases)
is_AUX_on logic statement to determine population statistics - is the AUX on? 0 no, 1 y...
is_COOL_on logic statement to determine population statistics - is the COOL on? 0 no, 1 ...
is_HEAT_on logic statement to determine population statistics - is the HEAT on? 0 no, 1 ...
Is_on
is_range_on simple logic output to determine state of range (1-on, 0-off)
is_waterheater_on simple logic output to determine state of waterheater (1-on, 0-off)
is_window_open defines the state of the window opening, 1=open, 2=closed
islanded_state FOUR QUADRANT MODEL: Boolean used to let control modes to act under island co...
iteration_count maximum number of iterations for steady state model
J moment of inertia
J2894_high_voltage_persistent_time J2894-suggsted higher-voltage momentary duration
J2894_high_voltage_persistent_value J2894-suggested higher-voltage momentary magnitude
J2894_highest_voltage_surge_time J2894-suggested high voltage surge threshold duration
J2894_highest_voltage_surge_value J2894-suggested high voltage surge threshold magnitude
J2894_is_ramp_constrained CHECKPOINT_VAR: internal variable for J2894 ramp constrained flag
J2894_low_voltage_persistent_time J2894-suggested lower-voltage momentary duration
J2894_low_voltage_persistent_value J2894-suggested lower-voltage momentary magnitude
J2894_lowest_voltage_surge_time J2894-suggested low voltage surge threshold duration
J2894_lowest_voltage_surge_value J2894-suggested low voltage surge threshold magnitude
J2894_off_accumulator CHECKPOINT_VAR: internal variable for J2894 off accumulator
J2894_outage_disconnect_interval J2894-suggested outage length, when criterion has been exceeded
J2894_ramp_rate_limit J2894-suggested ramp rate limit for charger activation
J2894_trip_method SAE J2894 threshold exceeded for the tripping
J2894_voltage_high_state_0 CHECKPOINT_VAR: internal variable for J2894 high-voltage state (index 0)
J2894_voltage_high_state_1 CHECKPOINT_VAR: internal variable for J2894 high-voltage state (index 1)
J2894_voltage_low_state_0 CHECKPOINT_VAR: internal variable for J2894 low-voltage state (index 0)
J2894_voltage_low_state_1 CHECKPOINT_VAR: internal variable for J2894 low-voltage state (index 1)
k coefficient of thermal conductivity (W/m/K)
k1
k2
K_ES_pu Polarisation voltage, per unit
K_p1 Real power coefficient for running state 1, puP/puV
K_p2 Real power coefficient for running state 2, puP/puV
K_q1 Reactive power coefficient for running state 1, puQ/puV
K_q2 Reactive power coefficient for running state 2, puQ/puV
KA Exciter gain (p
kdd DELTAMODE: The d-axis differentiator gain for the current modulation PID cont...
kdq DELTAMODE: The q-axis differentiator gain for the current modulation PID cont...
kdVdc DELTAMODE: derivative gain of Vdc_min controller
ki integrator gain
ki_QV parameter of the propotional control for secondary voltage control
ki_Vterminal DELTAMODE: The integrator gain for the VSI terminal voltage modulation
kic DELTAMODE: Integral gain of the current loop
kid DELTAMODE: The d-axis proportional gain for the current modulation PI control...
kiPLL DELTAMODE: Proportional gain of the PLL
kipmax DELTAMODE: The integral gain of Pmax controller
kiq DELTAMODE: The q-axis proportional gain for the current modulation PI control...
kiqmax DELTAMODE: proportional and integral gains for Qmax controller
kiv DELTAMODE: proportional gain and integral gain of voltage loop
kiVdc DELTAMODE: integral gain of Vdc_min controller
kp proportional gain
kp_QV parameter of the integral control for secondary voltage control
kp_Vterminal DELTAMODE: The proportional gain for the VSI terminal voltage modulation
kpc DELTAMODE: Proportional gain of the current loop
kpd DELTAMODE: The d-axis integration gain for the current modulation PI controll...
kpf proportional gain of frequency regulation
kpPLL DELTAMODE: Proportional gain of the PLL
kppmax DELTAMODE: The proportional gain of Pmax controller
kpq DELTAMODE: The q-axis integration gain for the current modulation PI controll...
kpqmax DELTAMODE: proportional and integral gains for Qmax controller
kpv DELTAMODE: proportional gain and integral gain of voltage loop
kpVdc DELTAMODE: proportional gain of Vdc_min controller
L_A Air core inductance of transformer
last_cooling_load stores the previous heating/cooling system load
last_current_A CHECKPOINT_VAR: Previously applied power output (used to remove from parent s...
last_current_B CHECKPOINT_VAR: Previously applied power output (used to remove from parent s...
last_current_C CHECKPOINT_VAR: Previously applied power output (used to remove from parent s...
last_current_D CHECKPOINT_VAR: Previously applied power output (used to remove from parent s...
last_DC_current CHECKPOINT_VAR: internal variable for last_DC_current
last_DC_power CHECKPOINT_VAR: internal variable for last_DC_power
last_duty_cycle CHECKPOINT_VAR: internal variable for last duty cycle
last_heating_load stores the previous heating/cooling system load
last_I_In CHECKPOINT_VAR: internal variable for last_I_In
last_I_Out_A CHECKPOINT_VAR: internal variable for last_I_Out[0]
last_I_Out_B CHECKPOINT_VAR: internal variable for last_I_Out[1]
last_I_Out_C CHECKPOINT_VAR: internal variable for last_I_Out[2]
last_mode_timer
last_power_A CHECKPOINT_VAR: Previously applied power output (as constant power) - used to...
last_power_B CHECKPOINT_VAR: Previously applied power output (as constant power) - used to...
last_power_C CHECKPOINT_VAR: Previously applied power output (as constant power) - used to...
last_power_D CHECKPOINT_VAR: Previously applied power output (as constant power) - used to...
last_system_mode heating/cooling system operation state
last_temperature CHECKPOINT_VAR: internal variable for last temperature in degF
last_time CHECKPOINT_VAR: internal variable for last_time
last_timestep CHECKPOINT_VAR: internal variable for last timestep
last_vv_check CHECKPOINT_VAR: internal variable for last_vv_check
latent_load_fraction fractional increase in cooling load due to latent heat
latitude Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form)
latitude_angle_fix Fix tilt angle to installation latitude value
length
lf_dispatch_change_allowed CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed
lf_dispatch_power CHECKPOINT_VAR: Amount of real power to try and dispatch to meet thresholds
load_class Flag to track load type, not currently used for anything except sorting
load_follow_status CHECKPOINT_VAR: Status variable for what the load_following mode is doing
load_priority Load classification based on priority
load_state
location whether the range is inside or outside
lockout_time Time for capacitor to remain locked out from further switching operations (VA...
long_compressor_cycle_due
long_compressor_cycle_energy
long_compressor_cycle_power
long_compressor_cycle_threshold
long_compressor_cycle_time
longitude Longitude, as written
loop The number of times the tape is repeated
low_load_deadband Low loading case voltage deadband for each regulator, separated by commas
low_temperature LEGACY MODEL: low temperature of linear control; defines slope
lower_heating_element_state MULTILAYER MODEL: The state of the lower heating element in the tank
lower_tank_deadband MULTILAYER_MODEL: The deadband for the lower heating element thermostat in th...
lower_tank_setpoint MULTILAYER_MODEL: The setpoint for the lower heating element thermostat in th...
lower_tank_temperature MULTILAYER_MODEL: The water temperature at the lower heating element thermost...
lower_taps number of regulator lower taps, or the minimum lower voltage tap position
lower_voltage_limit Lower voltage limit for the reconfiguration validity checks - per unit
Lr rotor synchronous reactance
Ls stator synchronous reactance
m12 CHECKPOINT_VAR: internal variable for m12
m23 CHECKPOINT_VAR: internal variable for m23
m34 CHECKPOINT_VAR: internal variable for m34
magnetization_location winding to place magnetization influence for in-rush calculations
MAIFI Displays annual MAIFI values as per IEEE 1366-2003
MAIFI_int Displays MAIFI values over the period specified by base_time_value as per IEE...
margin CHECKPOINT_VAR: internal variable for margin
mass_heat_capacity interior mass heat capacity
mass_heat_coeff interior mass heat exchange coefficient
mass_internal_gain_fraction fraction of heat gain/loss from the internal gains that goes to the mass
mass_solar_gain_fraction fraction of the heat gain/loss from the solar gains that goes to the mass
mass_temperature interior mass temperature
max_charge_rate FOUR QUADRANT MODEL: maximum rate the battery can be charged in LOAD_FOLLOWIN...
max_discharge_rate FOUR QUADRANT MODEL: maximum rate the battery can be discharged in LOAD_FOLLO...
Max_Ef COP: Synchronous generator maximum induced rotor voltage in p
max_node_voltage Per-unit maximum voltage level allowed for nodes
MAX_NR_ITERATIONS The allowed maximum number of newton-raphson itrations
max_number_of_tries the number of times the recloser will try to close before permanently opening
max_pwr_slew_rate
max_ramp_down_reactive DELTAMODE: The reactive power ramp down rate limit
max_ramp_down_real DELTAMODE: The real power ramp down rate limit
max_ramp_up_reactive DELTAMODE: The reactive power ramp up rate limit
max_ramp_up_real DELTAMODE: The real power ramp up rate limit
max_var_slew_rate
max_vdrop Maximum voltage drop between feeder and end measurements for each regulator, ...
Max_Vrotor COP: Induction generator maximum induced rotor voltage in p
maximum_charge_rate Maximum output rate of charger in kW
maximum_dc_power MULTIPOINT EFFICIENCY MODEL: the maximum dc power point for the efficiency cu...
maximum_dc_voltage MULTIPOINT EFFICIENCY MODEL: the maximum dc voltage point for the efficiency ...
maximum_overload_current Maximum overload current, in per-unit
maximum_speed_error maximum speed error for transitioning modes
maximum_voltage_error convergence voltage limit or convergence criteria
maximum_voltages Maximum voltages allowed for feeder, separated by commas
mdA DELTAMODE: The d-axis current modulation for phase A or triplex phase
mdB DELTAMODE: The d-axis current modulation for phase B
mdC DELTAMODE: The d-axis current modulation for phase C
mdc DELTAMODE: saturation limit of modulation index
mean_repair_time Time after a fault clears for the object to be back in service
mean_replacement_time
measured_angle_1 bus angle measurement, phase 1N
measured_angle_12 bus angle measurement, across the phases
measured_angle_2 bus angle measurement, phase 2N
measured_angle_A bus angle measurement, phase A
measured_angle_B bus angle measurement, phase B
measured_angle_C bus angle measurement, phase C
measured_avg_reactive_power_A_in_interval measured A phase average reactive power over a specified interval
measured_avg_reactive_power_B_in_interval measured B phase average reactive power over a specified interval
measured_avg_reactive_power_C_in_interval measured C phase average reactive power over a specified interval
measured_avg_reactive_power_in_interval measured average reactive power over a specified interval
measured_avg_real_power_A_in_interval measured A phase average real power over a specified interval
measured_avg_real_power_B_in_interval measured B phase average real power over a specified interval
measured_avg_real_power_C_in_interval measured C phase average real power over a specified interval
measured_avg_real_power_in_interval measured average real power over a specified interval
measured_avg_voltage_12_mag_in_interval measured average line-to-ground voltage magnitude on phase 12 over a specifie...
measured_avg_voltage_1_mag_in_interval measured average line-to-ground voltage magnitude on phase 1 over a specified...
measured_avg_voltage_2_mag_in_interval measured average line-to-ground voltage magnitude on phase 2 over a specified...
measured_avg_voltage_A_mag_in_interval measured avg line-to-neutral voltage magnitude on phase A over a specified in...
measured_avg_voltage_AB_mag_in_interval measured avg line-to-line voltage magnitude on phase A over a specified inter...
measured_avg_voltage_B_mag_in_interval measured avg line-to-neutral voltage magnitude on phase B over a specified in...
measured_avg_voltage_BC_mag_in_interval measured avg line-to-line voltage magnitude on phase B over a specified inter...
measured_avg_voltage_C_mag_in_interval measured avg line-to-neutral voltage magnitude on phase C over a specified in...
measured_avg_voltage_CA_mag_in_interval measured avg line-to-line voltage magnitude on phase C over a specified inter...
measured_current_1 measured current, phase 1
measured_current_2 measured current, phase 2
measured_current_A measured current on phase A
measured_current_B measured current on phase B
measured_current_C measured current on phase C
measured_current_N measured current, phase N
measured_demand greatest metered real power during simulation
measured_energy_delta_timestep Period of timestep for real and reactive delta energy calculation
measured_frequency frequency measurement - average of present phases
measured_frequency_1 frequency measurement, phase 1N
measured_frequency_12 frequency measurement, across the phases
measured_frequency_2 frequency measurement, phase 2N
measured_frequency_A frequency measurement, phase A
measured_frequency_B frequency measurement, phase B
measured_frequency_C frequency measurement, phase C
measured_imag_max_voltage_12_in_interval measured imaginary max line-to-ground voltage on phase 12 over a specified in...
measured_imag_max_voltage_1_in_interval measured imaginary max line-to-ground voltage on phase 1 over a specified int...
measured_imag_max_voltage_2_in_interval measured imaginary max line-to-ground voltage on phase 2 over a specified int...
measured_imag_min_voltage_12_in_interval measured imaginary min line-to-ground voltage on phase 12 over a specified in...
measured_imag_min_voltage_1_in_interval measured imaginary min line-to-ground voltage on phase 1 over a specified int...
measured_imag_min_voltage_2_in_interval measured imaginary min line-to-ground voltage on phase 2 over a specified int...
measured_power current total power
measured_power_A current measured power on phase A
measured_power_B current measured power on phase B
measured_power_C current measured power on phase C
measured_reactive_energy metered reactive energy consumption, cummalitive
measured_reactive_energy_delta delta in metered reactive energy consumption from last specified measured_ene...
measured_reactive_max_power_A_in_interval measured A phase maximum reactive power over a specified interval
measured_reactive_max_power_B_in_interval measured B phase maximum reactive power over a specified interval
measured_reactive_max_power_C_in_interval measured C phase maximum reactive power over a specified interval
measured_reactive_max_power_in_interval measured maximum reactive power over a specified interval
measured_reactive_max_voltage_A_in_interval measured reactive max line-to-neutral voltage on phase A over a specified int...
measured_reactive_max_voltage_AB_in_interval measured reactive max line-to-line voltage on phase A over a specified interv...
measured_reactive_max_voltage_B_in_interval measured reactive max line-to-neutral voltage on phase B over a specified int...
measured_reactive_max_voltage_BC_in_interval measured reactive max line-to-line voltage on phase B over a specified interv...
measured_reactive_max_voltage_C_in_interval measured reactive max line-to-neutral voltage on phase C over a specified int...
measured_reactive_max_voltage_CA_in_interval measured reactive max line-to-line voltage on phase C over a specified interv...
measured_reactive_min_power_A_in_interval measured A phase minimum reactive power over a specified interval
measured_reactive_min_power_B_in_interval measured B phase minimum reactive power over a specified interval
measured_reactive_min_power_C_in_interval measured C phase minimum reactive power over a specified interval
measured_reactive_min_power_in_interval measured minimum reactive power over a specified interval
measured_reactive_min_voltage_A_in_interval measured reactive min line-to-neutral voltage on phase A over a specified int...
measured_reactive_min_voltage_AB_in_interval measured reactive min line-to-line voltage on phase A over a specified interv...
measured_reactive_min_voltage_B_in_interval measured reactive min line-to-neutral voltage on phase B over a specified int...
measured_reactive_min_voltage_BC_in_interval measured reactive min line-to-line voltage on phase B over a specified interv...
measured_reactive_min_voltage_C_in_interval measured reactive min line-to-neutral voltage on phase C over a specified int...
measured_reactive_min_voltage_CA_in_interval measured reactive min line-to-line voltage on phase C over a specified interv...
measured_reactive_power metered reactive power
measured_real_energy metered real energy consumption, cummalitive
measured_real_energy_delta delta in metered real energy consumption from last specified measured_energy_...
measured_real_max_power_A_in_interval measured A phase maximum real power over a specified interval
measured_real_max_power_B_in_interval measured B phase maximum real power over a specified interval
measured_real_max_power_C_in_interval measured C phase maximum real power over a specified interval
measured_real_max_power_in_interval measured maximum real power over a specified interval
measured_real_max_voltage_12_in_interval measured real max line-to-ground voltage on phase 12 over a specified interva...
measured_real_max_voltage_1_in_interval measured real max line-to-ground voltage on phase 1 over a specified interval
measured_real_max_voltage_2_in_interval measured real max line-to-ground voltage on phase 2 over a specified interval
measured_real_max_voltage_A_in_interval measured real max line-to-neutral voltage on phase A over a specified interva...
measured_real_max_voltage_AB_in_interval measured real max line-to-line voltage on phase A over a specified interval
measured_real_max_voltage_B_in_interval measured real max line-to-neutral voltage on phase B over a specified interva...
measured_real_max_voltage_BC_in_interval measured real max line-to-line voltage on phase B over a specified interval
measured_real_max_voltage_C_in_interval measured real max line-to-neutral voltage on phase C over a specified interva...
measured_real_max_voltage_CA_in_interval measured real max line-to-line voltage on phase C over a specified interval
measured_real_min_power_A_in_interval measured A phase minimum real power over a specified interval
measured_real_min_power_B_in_interval measured B phase minimum real power over a specified interval
measured_real_min_power_C_in_interval measured C phase minimum real power over a specified interval
measured_real_min_power_in_interval measured minimum real power over a specified interval
measured_real_min_voltage_12_in_interval measured real min line-to-ground voltage on phase 12 over a specified interva...
measured_real_min_voltage_1_in_interval measured real min line-to-ground voltage on phase 1 over a specified interval
measured_real_min_voltage_2_in_interval measured real min line-to-ground voltage on phase 2 over a specified interval
measured_real_min_voltage_A_in_interval measured real min line-to-neutral voltage on phase A over a specified interva...
measured_real_min_voltage_AB_in_interval measured real min line-to-line voltage on phase A over a specified interval
measured_real_min_voltage_B_in_interval measured real min line-to-neutral voltage on phase B over a specified interva...
measured_real_min_voltage_BC_in_interval measured real min line-to-line voltage on phase B over a specified interval
measured_real_min_voltage_C_in_interval measured real min line-to-neutral voltage on phase C over a specified interva...
measured_real_min_voltage_CA_in_interval measured real min line-to-line voltage on phase C over a specified interval
measured_real_power metered real power
measured_stats_interval Period of timestep for min/max/average calculations
measured_voltage_1 measured voltage on phase 1
measured_voltage_12 measured voltage on phase 12
measured_voltage_2 measured voltage on phase 2
measured_voltage_A current measured voltage on phase A
measured_voltage_AB current measured voltage on phases AB
measured_voltage_B current measured voltage on phase B
measured_voltage_BC current measured voltage on phases BC
measured_voltage_C current measured voltage on phase C
measured_voltage_CA current measured voltage on phases CA
measured_voltage_N measured voltage, phase N to ground
mechanical_torque mechanical torque applied to the motor
mechanical_torque_state_var Internal state variable torque - three-phase model
meter_power_consumption metered power used for operating the meter; standby and communication losses
meter_type describes whether to collect from 3-phase or S-phase meters
metrics_period period when both metrics are satisfied
microgrid_power_limit Comma-separated power limit (complex VA) for microgrids during reconfiguratio...
microgrid_power_links Comma-separated list of link-based objects for monitoring power through
microgrid_vertex_list Comma-separated object list that defines the microgrid vertices
midpoint_temperature LEGACY MODEL: midpoint temperature of linear control; defines slope
mileage_classification Miles expected range on battery only
mileage_efficiency Efficiency of drive train in mile/kWh
Min_Ef COP: Synchronous generator minimum induced rotor voltage in p
min_node_voltage Per-unit minimum voltage level allowed for nodes
Min_Vrotor COP: Induction generator minimum induced rotor voltage in p
minimum_dc_power MULTIPOINT EFFICIENCY MODEL: the minimum dc power point for the efficiency cu...
minimum_voltages Minimum voltages allowed for feeder, separated by commas
mode
mode_status The current working mode status
momentary_count
monitored_power LEGACY MODEL: output only; power output value of parent meter when performing...
monitoring_period The user-defined period when this sync_ctrl object keeps on monitoring in mod...
monthly_bill Accumulator for the current month's bill
monthly_energy Accumulator for the current month's energy consumption
monthly_fee Once a month flat fee for customer hook-up
motor_coil_on_off
motor_coil_only_check1
motor_coil_only_check2
motor_coil_only_check3
motor_coil_only_check4
motor_coil_only_check5
motor_coil_only_check6
motor_efficiency when using motor model, describes the efficiency of the motor
motor_model indicates the level of detail used in modelling the hvac motor parameters
motor_on_off
motor_only_25_repeat_one CHECKPOINT_VAR: internal flag for motor only 25 repeat one
motor_only_check1
motor_only_check2
motor_only_check3
motor_only_check4
motor_only_check5
motor_only_check6
motor_only_check7
motor_only_check8
motor_only_check9
motor_only_temp1
motor_only_temp2
motor_operation_type current operation type of the motor - deltamode related
motor_poles Number of Motor Poles
motor_power
motor_status the current status of the motor
motor_status_number the current status of the motor as an integer
motor_trip boolean variable to check if motor is tripped
mp DELTAMODE: P-f droop gain, usually 3
mq DELTAMODE: Q-V droop gain, usually 0
mq_QV_Droop Q-V droop slope
mqA DELTAMODE: The q-axis current modulation for phase A or triplex phase
mqB DELTAMODE: The q-axis current modulation for phase B
mqC DELTAMODE: The q-axis current modulation for phase C
msg_mode messages regarding remote node voltage to come internally from gridlabd or ex...
multiplier this variable is used to modify the base power as a function of multiplier x ...
n ratio of stator auxiliary windings to stator main windings
n_max_ext_1 maximum Turn ratio for phase 1 (triplex)
n_max_ext_2 maximum Turn ratio for phase 2 (triplex)
n_max_ext_A maximum Turn ratio for phase A
n_max_ext_B maximum Turn ratio for phase B
n_max_ext_C maximum Turn ratio for phase C
n_min_ext_1 minimum Turn ratio for phase 1 (triplex)
n_min_ext_2 minimum Turn ratio for phase 2 (triplex)
n_min_ext_A minimum Turn ratio for phase A
n_min_ext_B minimum Turn ratio for phase B
n_min_ext_C minimum Turn ratio for phase C
N_p1 Real power exponent for running state 1
N_p2 Real power exponent for running state 2
N_q1 Reactive power exponent for running state 1
N_q2 Reactive power exponent for running state 2
name The object's name; unique across the model
Naturalgas_CO2
Naturalgas_Conv_Eff
Naturalgas_emissions_CO2
Naturalgas_emissions_NOx
Naturalgas_emissions_SO2
Naturalgas_Max_Out
Naturalgas_NOx
Naturalgas_Order
Naturalgas_Out
Naturalgas_SO2
negative_sequence_voltage The negative sequence representation of the voltage for the substation object
neutral_diameter Diameter of individual neutral conductor/strand of concentric neutral
neutral_gmr Geometric mean radius of an individual neutral conductor/strand
neutral_resistance Resistance of an individual neutral conductor/strand in ohm/mile
neutral_strands Number of cable strands in neutral conductor
new_running_state CHECKPOINT_VAR: internal variable for new running state
next_t
next_time CHECKPOINT_VAR: internal variable for next time
next_timestep CHECKPOINT_VAR: internal variable for next timestep
next_update_time CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed
no_load_loss Another method of specifying transformer impedances, defined as per unit powe...
no_of_defrost CHECKPOINT_VAR: internal variable for number of defrosts
NOCT
nominal_frequency
nominal_output_frequency Nominal VFD output frequency
nominal_power the rated amount of power demanded by devices that are on
nominal_volt_v Measurement Property: Nominal voltage of from/to node of the parent switch
nominal_voltage
normal_perc
NORMAL_PREWASH_ENERGY
NORMAL_PREWASH_POWER
NORMAL_SMALLWASH_ENERGY
NORMAL_SMALLWASH_POWER
NORMAL_SPIN_HIGH_ENERGY
NORMAL_SPIN_HIGH_POWER
NORMAL_SPIN_LOW_ENERGY
NORMAL_SPIN_LOW_POWER
NORMAL_SPIN_MEDIUM_ENERGY
NORMAL_SPIN_MEDIUM_POWER
NORMAL_WASH_ENERGY
NORMAL_WASH_POWER
north_incident_solar_radiation incident solar radiation hitting the north side of the house
northeast_incident_solar_radiation incident solar radiation hitting the northeast side of the house
northwest_incident_solar_radiation incident solar radiation hitting the northwest side of the house
Norton_dynamic Flag to indicate a Norton-equivalent connection -- used for generators and de...
Norton_dynamic_child Flag to indicate a Norton-equivalent connection is made by a childed node obj...
NOx_emission Total NOx emissions (lbs) based on fuel usage
NR_first_run CHECKPOINT_VAR: internal variable for NR_first_run
NR_powerflow_parent NR powerflow - actual powerflow parent - used by generators accessing child o...
Nuclear_CO2
Nuclear_Conv_Eff
Nuclear_emissions_CO2
Nuclear_emissions_NOx
Nuclear_emissions_SO2
Nuclear_Max_Out
Nuclear_NOx
Nuclear_Order
Nuclear_Out
Nuclear_SO2
number_battery_state_changes LEGACY MODEL: Number of times battery switches between charging and dischargi...
number_of_devices Number of devices to model - base power is the total load of all devices
number_of_devices_off Total number of devices that are off
number_of_devices_on Total number of devices that are on
number_of_doors ratio of door area to wall area
number_of_occupants
number_of_phases_out Exposed variable - hidden for solar
number_of_poles number of poles
number_of_stories number of stories within the structure
number_of_tries Current number of tries recloser has attempted
number_poles Number of poles in the generator
occupancy_fraction
off_nominal_time CHECKPOINT_VAR: internal variable for off nominal time
oil_volume The number of gallons of oil in the transformer
omega_ref Reference frequency of generator (rad/s)
operating_mode Defines whether the switch operates in a banked or per-phase control mode
operation operation to perform on complex property types
orientation
orientation_azimuth Facing direction of the PV array
out_of_violation_time_total CHECKPOINT_VAR: internal variable for out_of_violation_time_total
out_svc Timestamp the object leaves service
outdoor_rh outdoor relative humidity
outdoor_temperature outdoor air temperature
outer_diameter Outer diameter of conductor and sheath
output output scaling value
output_current
output_current_a
output_current_m
output_filename Output filename for list of unsupported nodes
output_imped_p
output_imped_q
output_impedance
output_power
output_power_p
output_power_q
output_voltage Energy storage DC output voltage
outputEnergy Total energy(kWh) output from the generator
outside_temp
oven_check
oven_demand the hot food take out from the oven
oven_demand_old CHECKPOINT_VAR: internal variable for oven_demand_old
oven_diameter the diameter of the oven
oven_run_prob
oven_setpoint the temperature around which the oven will heat its contents
oven_UA the UA of the oven (surface area divided by R-value)
oven_volume the volume of the oven
over_freq_high_band_viol_time CHECKPOINT_VAR: OF2 violation accumulator
over_freq_high_cutout DELTAMODE: OF2 set point for IEEE 1547a
over_freq_high_disconnect_time DELTAMODE: OF2 clearing time for IEEE1547a
over_freq_low_band_viol_time CHECKPOINT_VAR: OF1 violation accumulator
over_freq_low_cutout DELTAMODE: OF1 set point for IEEE 1547a
over_freq_low_disconnect_time DELTAMODE: OF1 clearing time for IEEE 1547a
over_sizing_factor over sizes the heating and cooling system from standard specifications (0
over_voltage_high_cutout High voltage value for overvoltage
over_voltage_high_disconnect_time Highest voltage clearing time for overvoltage
over_voltage_high_viol_time CHECKPOINT_VAR: Highest high voltage threshold violation accumulator
over_voltage_low_cutout Lowest voltage value for overvoltage
over_voltage_low_disconnect_time Lowest voltage clearing time for overvoltage
over_voltage_low_viol_time CHECKPOINT_VAR: Lowest high voltage threshold violation accumulator
overload_limit per-unit value of the maximum power the generator can provide
overloaded_status overloaded status (true/false)
override override the load state: NORMAL, ON or OFF
P_0 Computed power curve initialization point - real power
P_CONSTANT_err4
P_CONSTANT_FuelFlow
P_CONSTANT_GovOutPut
P_CONSTANT_ki parameter of the integration control for constant P mode
P_CONSTANT_kp parameter of the proportional control for constant P mode
P_CONSTANT_Kturb Turbine gain (>0
P_CONSTANT_Pref Pref input to governor controls (per-unit), if supported
P_CONSTANT_rclose Minimum valve closing rate, p
P_CONSTANT_ropen Maximum valve opening rate, p
P_CONSTANT_Tact Actuator time constant
P_CONSTANT_Tb Turbine lag time constant, sec
P_CONSTANT_Tc Turbine lead time constant, sec
P_CONSTANT_Teng Transport lag time constant for diesel engine
P_CONSTANT_Tpelec Electrical power transducer time constant, sec
P_CONSTANT_ValveStroke
P_CONSTANT_wfnl No load fuel flow, p
P_CONSTANT_x1
P_CONSTANT_x4
P_CONSTANT_x4a
P_CONSTANT_x4b
P_CONSTANT_x5
P_CONSTANT_x5a
P_CONSTANT_x5b
P_CONSTANT_x_Pconstant
P_converted COP: Amount of electrical power converted from mechanical power delivered
P_ES_pu ES output active power, per unit
P_f_droop DELTAMODE: P-f droop gain in per unit value, usually 0
P_f_droop_setting_mode Definition of P-f droop curve
p_go_home
p_go_work
P_In DC power
P_Max LEGACY MODEL: the maximum power output of the battery
p_measure DELTAMODE: filtered active power for grid-forming inverter
P_Out FOUR QUADRANT MODEL: Scheduled real power out in CONSTANT_PQ control mode
P_val real power portion of motor power consumption calculation
pa_vw_limited CHECKPOINT_VAR: internal variable for pa_vw_limited
panel total panel enduse load
panel_type
parasitic_power_draw LEGACY MODEL: the parasytic power draw of the battery when idle
parent The parent object's name
parent_is_inverter CHECKPOINT_VAR: internal variable for parent_is_inverter
parent_is_meter CHECKPOINT_VAR: internal variable for parent_is_meter
parent_is_triplex CHECKPOINT_VAR: internal variable for parent_is_triplex
pb_vw_limited CHECKPOINT_VAR: internal variable for pb_vw_limited
Pbase motor rated size
pc_vw_limited CHECKPOINT_VAR: internal variable for pc_vw_limited
pCircuit_V_Avg DELTAMODE: three-phase average value of terminal voltage
pCircuit_V_Avg_pu DELTAMODE: three-phase average value of terminal voltage, per unit value
Pconv COP: Amount of electrical power converted from mechanical power delivered
pdispatch Scheduled flow from->to in W
pdispatch_offset Offset to scheduled flow from->to in W
peak_demand the peak power consumption since the last meter reading
peak_S
per_unit_rotor_speed rotor speed in per-unit
percent_loss_of_life the percent loss of life
period time interval to apply duty cycle
perm_press_perc
PERMPRESS_PREWASH_ENERGY
PERMPRESS_PREWASH_POWER
PERMPRESS_SMALLWASH_ENERGY
PERMPRESS_SMALLWASH_POWER
PERMPRESS_SPIN_HIGH_ENERGY
PERMPRESS_SPIN_HIGH_POWER
PERMPRESS_SPIN_LOW_ENERGY
PERMPRESS_SPIN_LOW_POWER
PERMPRESS_SPIN_MEDIUM_ENERGY
PERMPRESS_SPIN_MEDIUM_POWER
PERMPRESS_WASH_ENERGY
PERMPRESS_WASH_POWER
Petroleum_CO2
Petroleum_Conv_Eff
Petroleum_emissions_CO2
Petroleum_emissions_NOx
Petroleum_emissions_SO2
Petroleum_Max_Out
Petroleum_NOx
Petroleum_Order
Petroleum_Out
Petroleum_SO2
pf COP: Desired power factor in CONSTANTP mode (can be modified over time)
pf_high
pf_low
pf_phase Phase to include in power factor monitoring
pf_reg Activate (or not) power factor regulation in four_quadrant_control_mode
pf_reg_activate FOUR QUADRANT MODEL: Lowest acceptable power-factor level below which power-f...
pf_reg_activate_lockout_time FOUR QUADRANT MODEL: Mandatory pause between the deactivation of power-factor...
pf_reg_deactivate FOUR QUADRANT MODEL: Lowest acceptable power-factor above which no power-fact...
pf_reg_dispatch_change_allowed CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed for power...
pf_reg_dispatch_VAR CHECKPOINT_VAR: (Reactive only?) power dispatched to meet power factor regula...
pf_reg_high FOUR QUADRANT MODEL: Upper limit for power-factor - if exceeds, go full rever...
pf_reg_low FOUR QUADRANT MODEL: Lower limit for power-factor - if exceeds, stop regulati...
pf_reg_next_update_time CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed
pf_reg_status CHECKPOINT_VAR: internal variable for pf_reg_status
pf_signed Set to true to consider the sign on the power factor
pf_target FOUR QUADRANT MODEL: Desired power-factor to maintain (signed) positive is in...
phase initial phase of load; duty will be assumed to occur at beginning of period
phase_1_state Defines if phase 1 is in bypass or not
phase_2_state Defines if phase 2 is in bypass or not
phase_A_impedance Series impedance of reactor on phase A
phase_A_primary_flux_value instantaneous magnetic flux in phase A on the primary side of the transformer...
phase_A_reactance Reactive portion of phase A's impedance
phase_A_resistance Resistive portion of phase A's impedance
phase_A_secondary_flux_value instantaneous magnetic flux in phase A on the secondary side of the transform...
phase_A_state Defines if phase A is in bypass or not
phase_A_status
phase_angle_correction DELTAMODE: Boolean used to indicate whether inverter applies phase angle corr...
phase_B_impedance Series impedance of reactor on phase B
phase_B_primary_flux_value instantaneous magnetic flux in phase B on the primary side of the transformer...
phase_B_reactance Reactive portion of phase B's impedance
phase_B_resistance Resistive portion of phase B's impedance
phase_B_secondary_flux_value instantaneous magnetic flux in phase B on the secondary side of the transform...
phase_B_state Defines if phase B is in bypass or not
phase_B_status
phase_C_impedance Series impedance of reactor on phase C
phase_C_primary_flux_value instantaneous magnetic flux in phase C on the primary side of the transformer...
phase_C_reactance Reactive portion of phase C's impedance
phase_C_resistance Resistive portion of phase C's impedance
phase_C_secondary_flux_value instantaneous magnetic flux in phase C on the secondary side of the transform...
phase_C_state Defines if phase C is in bypass or not
phase_C_status
phase_loss_protection Trip all three phases of the load if a fault occurs
phaseA_I_Following AC current on A phase in three-phase system, only for grid_following
phaseA_I_Forming AC current on A phase in three-phase system, only for grid_forming
phaseA_I_Out AC current on A phase in three-phase system; 240-V connection on a triplex sy...
phaseA_I_Out_PU AC current on A phase in three-phase system, pu
phaseA_V_Out AC voltage on A phase in three-phase system; 240-V connection on a triplex sy...
phaseB_I_Following AC current on B phase in three-phase system, only for grid_following
phaseB_I_Forming AC current on B phase in three-phase system, only for grid_forming
phaseB_I_Out AC current on B phase in three-phase system
phaseB_I_Out_PU AC current on B phase in three-phase system, pu
phaseB_V_Out AC voltage on B phase in three-phase system
phaseC_I_Following AC current on C phase in three-phase system, only for grid_following
phaseC_I_Forming AC current on C phase in three-phase system, only for grid_forming
phaseC_I_Out AC current on C phase in three-phase system
phaseC_I_Out_PU AC current on C phase in three-phase system, pu
phaseC_V_Out AC voltage on C phase in three-phase system
phases
phases_connected phases capacitors connected to
phi duty cycle of the device
phi_K Knee flux value where the air core inductance interstes the flux axis of the ...
phi_M Peak magnetization flux at rated voltage of the saturation curve
phinr_cj conjugate of negative sequence rotor flux
phins_cj conjugate of negative sequence stator flux
phipr positive sequence rotor flux
phips positive sequence stator flux
pi_freq_ki The user-defined integral gain constant of the PI controller for adjusting th...
pi_freq_kp The user-defined proportional gain constant of the PI controller for adjustin...
pi_freq_lb_pu The lower bound of the output (i
pi_freq_ub_pu The upper bound of the output (i
pi_volt_mag_ki The user-defined integral gain constant of the PI controller for adjusting th...
pi_volt_mag_kp The user-defined proportional gain constant of the PI controller for adjustin...
pi_volt_mag_lb_pu The lower bound of the output (i
pi_volt_mag_ub_pu The upper bound of the output (i
Pinit Initial assumed real power loading of connected terminal
placement lighting location (affects where heatgains go)
pll_Ki Integration gain of PLL frequency measurement
pll_Kp Proportional gain of PLL frequency measurement
PM10_emission Total PM-10 emissions (lbs) based on fuel usage
Pmax DELTAMODE: power limit of grid forming inverter
Pmax_Low_Limit DELTAMODE: output limit of Pmax controller
Pmax_temp_coeff
Pmin DELTAMODE: power limit of grid forming inverter
positive_sequence_voltage The positive sequence representation of the voltage for the substation object
power the total power consumption of the load
power_1 accumulator - used for debugging/interfacing only - power on phase 1 (120V)
power_12 accumulator - used for debugging/interfacing only - power on phase 1 to 2 (24...
power_2 accumulator - used for debugging/interfacing only - power on phase 2 (120V)
power_A bus power injection (in = positive), this an accumulator only, not a output o...
power_AB bus power delta-connected injection (in = positive), this an accumulator only...
power_AN bus power wye-connected injection (in = positive), this an accumulator only, ...
power_B bus power injection (in = positive), this an accumulator only, not a output o...
power_BC bus power delta-connected injection (in = positive), this an accumulator only...
power_BN bus power wye-connected injection (in = positive), this an accumulator only, ...
power_C bus power injection (in = positive), this an accumulator only, not a output o...
power_CA bus power delta-connected injection (in = positive), this an accumulator only...
power_CN bus power wye-connected injection (in = positive), this an accumulator only, ...
power_convergence_value Default convergence criterion before power is posted to pw_load objects if co...
power_curve_csv Name of
power_curve_pu Flag when set indicates that user provided power curve has power values in p
power_density installed power density
power_factor Compressor power factor
power_fraction the fraction of the total power that is constant power (pu)
power_fraction_1 this is the constant power fraction of base power on phase 1
power_fraction_12 this is the constant power fraction of base power on phase 12
power_fraction_2 this is the constant power fraction of base power on phase 2
power_fraction_A this is the constant power fraction of base power on phase A
power_fraction_B this is the constant power fraction of base power on phase B
power_fraction_C this is the constant power fraction of base power on phase C
power_in power flow in (w
power_in_A power flow in (w
power_in_B power flow in (w
power_in_C power flow in (w
power_losses power losses
power_losses_A power losses, phase A
power_losses_B power losses, phase B
power_losses_C power losses, phase C
power_market Market (auction object) where the price is being received from
power_out power flow out (w
power_out_A power flow out (w
power_out_B power flow out (w
power_out_C power flow out (w
power_out_real power flow out (w
power_pf power factor for constant power portion
power_pf_1 in similar format as ZIPload, this is the power factor of the phase 1 constan...
power_pf_12 in similar format as ZIPload, this is the power factor of the phase 12 consta...
power_pf_2 in similar format as ZIPload, this is the power factor of the phase 2 constan...
power_pf_A in similar format as ZIPload, this is the power factor of the phase A constan...
power_pf_B in similar format as ZIPload, this is the power factor of the phase B constan...
power_pf_C in similar format as ZIPload, this is the power factor of the phase C constan...
power_rating kVA rating of transformer, total
power_set_high LEGACY MODEL: high set point of dead band for load following (POWER_DRIVEN)
power_set_high_highT LEGACY MODEL: high set point of dead band for load following at higher temper...
power_set_low LEGACY MODEL: low set point of dead band for load following (POWER_DRIVEN)
power_set_low_highT LEGACY MODEL: low set point of dead band for load following at higher tempera...
power_state the power state: OFF, ON or UNKNOWN
power_train_efficiency Miles per kWh of battery charge
power_transducer_ratio potential transformer rating
power_transferred LEGACY MODEL: the power output of the battery
power_type LEGACY MODEL: Not currently used
power_value motor power consumption
powerA_rating kVA rating of transformer, phase A
powerB_rating kVA rating of transformer, phase B
powerC_rating kVA rating of transformer, phase C
powers
Pp
Pp_H
Pp_R
Pp_S
Pp_T
Pp_W
Pq
Pq_H
Pq_R
Pq_S
Pq_T
Pq_W
pre_load
predictor_vals_Pref_ctrl CHECKPOINT_VAR: Predictor pass values of variables - Pref_ctrl
predictor_vals_Vset_ctrl CHECKPOINT_VAR: Predictor pass values of variables - Vset_ctrl
predictor_vals_Vset_ref CHECKPOINT_VAR: internal variable for predictor_vals
predictor_vals_w_measured CHECKPOINT_VAR: internal variable for predictor_vals
predictor_vals_wref_ctrl CHECKPOINT_VAR: internal variable for predictor_vals
predictor_vals_x CHECKPOINT_VAR: Predictor pass values of variables - x
predictor_vals_x_QV CHECKPOINT_VAR: internal variable for predictor_vals
Pref Pref input to governor controls (per-unit), if supported
Pref_droop_pu DELTAMODE: power reference in frequency-watt
Pref_max DELTAMODE: the upper and lower limits of power references in grid-following m...
Pref_min DELTAMODE: the upper and lower limits of power references in grid-following m...
prerotated_current_1 deltamode-functionality - bus current injection (in = positive), but will not...
prerotated_current_12 deltamode-functionality - bus current injection (in = positive), but will not...
prerotated_current_2 deltamode-functionality - bus current injection (in = positive), but will not...
prerotated_current_A deltamode-functionality - bus current injection (in = positive), but will not...
prerotated_current_B deltamode-functionality - bus current injection (in = positive), but will not...
prerotated_current_C deltamode-functionality - bus current injection (in = positive), but will not...
prev_current12 CHECKPOINT_VAR: internal variable for prev_current12
prev_current_A CHECKPOINT_VAR: internal variable for prev_current[0]
prev_current_B CHECKPOINT_VAR: internal variable for prev_current[1]
prev_current_C CHECKPOINT_VAR: internal variable for prev_current[2]
prev_demand CHECKPOINT_VAR: internal variable for previous demand
prev_state CHECKPOINT_VAR: 1 is charging, 0 is nothing, -1 is discharging
prev_time CHECKPOINT_VAR: internal variable for prev_time
prev_time_dbl CHECKPOINT_VAR: Tracking variable for 1547 checks and ramp rates
prev_VA_out_A AC power on A phase in three-phase system; 240-V connection on a triplex syst...
prev_VA_out_B AC power on B phase in three-phase system
prev_VA_out_C AC power on C phase in three-phase system
prev_value_IGenerated_A CHECKPOINT_VAR: internal variable for prev_value_IGenerated[0]
prev_value_IGenerated_B CHECKPOINT_VAR: internal variable for prev_value_IGenerated[1]
prev_value_IGenerated_C CHECKPOINT_VAR: internal variable for prev_value_IGenerated[2]
previous_load the actual load based on current voltage stored for use in controllers
previous_monthly_bill Total monthly bill for the previous month
previous_monthly_energy Total monthly energy for the previous month
previous_uptime Previous time between disconnects of node in minutes
prevTemp CHECKPOINT_VAR: internal variable for prevTemp
prevTime CHECKPOINT_VAR: internal variable for prevTime
price current price of electricity
price_base Used only in TIERED_RTP mode to describe the price before the first tier
primary_voltage primary voltage level in L-L value kV
property The parent's property the rows set (unset with no parent; the player's own va...
Pset Pset input to governor controls (per-unit), if supported
psi_b backward rotating flux
psi_dr Rotor d axis flux
psi_f forward rotating flux
psi_qr Rotor q axis flux
pt_phase Phase(s) that the PT is on, used as measurement points for control
PT_phase phase(s) monitored by PT
pulse_interval_1
pulse_interval_10
pulse_interval_11
pulse_interval_12
pulse_interval_13
pulse_interval_14
pulse_interval_15
pulse_interval_16
pulse_interval_17
pulse_interval_18
pulse_interval_19
pulse_interval_2
pulse_interval_3
pulse_interval_4
pulse_interval_5
pulse_interval_6
pulse_interval_7
pulse_interval_8
pulse_interval_9
pvc_a1_inv_cels In the calculation of dI, this is the coefficient that adjusts the difference...
pvc_b1_inv_cels In the calculation of dU, this is the coefficient that adjusts the difference...
pvc_I_m_A Current at maximum power point
pvc_I_sc_A The short circuit current
pvc_Pmax P max from the PV curve
pvc_Pmax_calc_simp_mode If the simple mode is selected, the pvc_Pmax = pvc_U_m_V * pvc_I_m_A
pvc_U_m_V Voltage at maximum power point
pvc_U_oc_V The open circuit voltage
pwr_electric Current electrical output of machine
pwr_electric_init CHECKPOINT_VAR: internal variable for pwr_electric_init
pwr_mech Current mechanical output of machine
Q1 FOUR QUADRANT MODEL: VAR point 1 in volt/var curve
Q2 FOUR QUADRANT MODEL: VAR point 2 in volt/var curve
Q3 FOUR QUADRANT MODEL: VAR point 3 in volt/var curve
Q4 FOUR QUADRANT MODEL: VAR point 4 in volt/var curve
Q_0 Computed power curve initialization point - reactive power
Q_ES Energy of ES
q_measure DELTAMODE: filtered reactive power for grid-forming inverter
Q_Out FOUR QUADRANT MODEL: Schedule reactive power out in CONSTANT_PQ control mode
Q_V_droop DELTAMODE: Q-V droop gain, usually 0
Q_val reactive power portion of motor power consumption calculation
Qa
Qbase_ES Rated capacity of ES, unit Wh
Qh
Qi
Qlatent CHECKPOINT_VAR: internal variable for Qlatent
Qm
Qmax DELTAMODE: maximum limit and minimum limit of Qmax controller and Qmin contro...
Qmin DELTAMODE: maximum limit and minimum limit of Qmax controller and Qmin contro...
Qref Qref input to govornor or AVR controls (per-unit), if supported
Qref_max DELTAMODE: the upper and lower limits of reactive power references in grid-fo...
Qref_min DELTAMODE: the upper and lower limits of reactive power references in grid-fo...
queue the total laundry accumulated
queue_cooktop number of loads accumulated
queue_max
queue_min
queue_oven number of loads accumulated
r1
r2
R_core COP: Induction generator primary core resistance in p
R_ES_pu ES internal resitance, per unit
R_fp DELTAMODE: The droop parameter of the f/p droop
R_rotor COP: Induction generator primary rotor resistance in p
R_stator COP: Induction generator primary stator resistance in p
R_vq DELTAMODE: The droop parameter of the v/q droop
Ra Stator resistance (p
raise_taps number of regulator raise taps, or the maximum raise voltage tap position
rampDownRate_reactive DELTAMODE: ramp rate for grid-following volt-var
rampDownRate_real DELTAMODE: ramp rate for grid-following frequency-watt
rampUpRate_reactive DELTAMODE: ramp rate for grid-following volt-var
rampUpRate_real DELTAMODE: ramp rate for grid-following frequency-watt
rank Solver rank
rate_of_cooling rate at which devices cool down
rate_of_heating rate at which devices heat up
rated_battery_power FOUR QUADRANT MODEL: The rated power of battery when battery is attached
rated_capacity
rated_DC_Voltage The rated dc bus of the inverter
rated_horse_power Rated Horse Power of the VFD
Rated_Insolation
rated_motor_speed Rated speed of the VFD in RPM
rated_output_voltage Line to Line Voltage - VFD Rated voltage
rated_power INTERNAL BATTERY MODEL: the rated power output of the battery
rated_top_oil_rise top-oil hottest-spot rise over ambient temperature at rated load, degrees C
Rated_V nominal line-line voltage in Volts
Rated_VA nominal capacity in VA
rated_winding_hot_spot_rise winding hottest-spot rise over ambient temperature at rated load, degrees C
rated_winding_time_constant The rated winding time constant in hours
rating_summer_continuous amp rating in summer, continuous
rating_summer_emergency amp rating in summer, short term
rating_winter_continuous amp rating in winter, continuous
rating_winter_emergency amp rating in winter, short term
ratio_f_p Ratio of frequency deviation to real power output change of diesel_dg
Rdoors door R-value
Rds d-axis resistance - single-phase model
re_override the override setting for the water heater
reactance Series impedance, pu, imag
reactance1 Secondary series impedance (only used when you want to define each individual...
reactance2 Secondary series impedance (only used when you want to define each individual...
reactance_resistance_ratio the reactance to resistance ratio (X/R)
reactive_power_generation The total reactive power generation
reactive_power_out_A Reactive power output of phase A
reactive_power_out_B Reactive power output of phase B
reactive_power_out_C Reactive power output of phase C
real Real component
real_power_generation The total real power generation
real_power_out_A Real power output of phase A
real_power_out_B Real power output of phase B
real_power_out_C Real power output of phase C
realized_charge_rate Implemented charge rate of the vehicle - grid-influence result of actual_char...
realPowerChange Real power output change of diesel_dg
recalculate CHECKPOINT_VAR: internal variable for recalculate
recharge CHECKPOINT_VAR: internal variable for recharge
recharge_pf installed compressor power factor
recharge_power installed compressor power usage
recharge_schedule_type Scheduling method for charging
recharge_time Flag indicating if recharging is available at the current time (1 or 0)
reconfig_attempts Number of reconfigurations/timestep to try before giving up
reconfig_iteration_limit Number of iterations to let PF go before flagging this as a bad reconfigurati...
reconnect current time since motor was tripped
reconnect_time time before tripped motor reconnects
reconnect_time_tracker internal reconnect time tracker variable
recover_rate The rate that the voltage goes back to nominal, unit: pu/s
recovery_duty_cycle fraction of time in the on state, while in recovery interval
rectifier_type
reference_bus reference bus from which frequency is defined
reference_phase The reference phase for the positive sequence voltage
refrigerator_power
Region
regulation regulation of voltage regulator in %
regulator_delay Default regulator time delay - overriden by local definitions
regulator_list List of voltage regulators for the system, separated by commas
regulator_resistance The resistance value of the regulator when it is not blown
reliability_mode General flag indicating if fault_check is operating under faulting or restora...
remainon
remote_sense Remote object for sensing values used for control schemes
remote_sense_B Secondary Remote object for sensing values used for control schemes (VARVOLT ...
remote_voltage_A remote node voltage, Phase A to ground
remote_voltage_B remote node voltage, Phase B to ground
remote_voltage_C remote node voltage, Phase C to ground
repair_dist_type
reserve_state_of_charge INTERNAL BATTERY MODEL: the reserve state of charge the battery can reach
reset_delay
reset_disabled_island_state Deltamode/multi-island flag -- used to reset disabled status (and reform an i...
residential_nominal_current_1 posted current on phase 1 from a residential object, if attached
residential_nominal_current_12 posted current on phase 1 to 2 from a residential object, if attached
residential_nominal_current_12_imag posted current on phase 1 to 2, imag, from a residential object, if attached
residential_nominal_current_12_real posted current on phase 1 to 2, real, from a residential object, if attached
residential_nominal_current_1_imag posted current on phase 1, imag, from a residential object, if attached
residential_nominal_current_1_real posted current on phase 1, real, from a residential object, if attached
residential_nominal_current_2 posted current on phase 2 from a residential object, if attached
residential_nominal_current_2_imag posted current on phase 2, imag, from a residential object, if attached
residential_nominal_current_2_real posted current on phase 2, real, from a residential object, if attached
residential_nominal_current_A posted current on phase A from a residential object, if attached
residential_nominal_current_A_imag posted current on phase A, imag, from a residential object, if attached
residential_nominal_current_A_real posted current on phase A, real, from a residential object, if attached
residential_nominal_current_B posted current on phase B from a residential object, if attached
residential_nominal_current_B_imag posted current on phase B, imag, from a residential object, if attached
residential_nominal_current_B_real posted current on phase B, real, from a residential object, if attached
residential_nominal_current_C posted current on phase C from a residential object, if attached
residential_nominal_current_C_imag posted current on phase C, imag, from a residential object, if attached
residential_nominal_current_C_real posted current on phase C, real, from a residential object, if attached
resistance resistance in Ohms/mile of the conductor
resistance1 Secondary series impedance (only used when you want to define each individual...
resistance2 Secondary series impedance (only used when you want to define each individual...
retry_time the amount of time in seconds to wait before the recloser attempts to close
return_time CHECKPOINT_VAR: internal variable for return time
reverse_flow_control Type of control used when power is flowing in reverse through the regulator
rfb_size Default settings for certain sizes of batteries
Rfilter DELTAMODE: per-unit values of inverter filter
Rfloor floor R-value
Rg COP: Synchronous generator grounding resistance in p
Rinternal LEGACY MODEL: the internal resistance of the battery
rotor_angle rotor angle state variable
rotor_speed rotor speed
rotor_speed_convergence Convergence criterion on rotor speed used to determine when to exit deltamode
rotor_speed_convergence_enabled Uses rotor_speed_convergence to determine if an exit of deltamode is needed
roughness_length_factor European Wind Atlas unitless correction factor for adjusting wind speed at va...
round_trip_efficiency INTERNAL BATTERY MODEL: the round trip efficiency of the battery according to...
Rp DELTAMODE: p-f droop gain in frequency-watt
Rq DELTAMODE: Q-V droop gain in volt-var
Rqs q-asis resistance - single-phase model
Rr rotor resistance
Rroof roof R-value
Rs stator resistance - three-phase model
run_defrost
runcount the number of times the file has been written to
runtime the time to check voltage data
Rwall wall R-value
Rwindows window R-value
s_flag
S_ref_wpm2 The referenced insolation
SAIDI Displays annual SAIDI values as per IEEE 1366-2003
SAIDI_int Displays SAIDI values over the period specified by base_time_value as per IEE...
SAIFI Displays annual SAIFI values as per IEEE 1366-2003
SAIFI_int Displays SAIFI values over the period specified by base_time_value as per IEE...
Sbase_ES Rated rating of ES
scheduled_power LEGACY MODEL: real power output of battery/inverter system
sct_freq_cv_arm_flag True - apply the freq controlled variable, False - do not set the related pro...
sct_volt_cv_arm_flag True - apply the volt controlled variable, False - do not set the related pro...
second_tier_energy switching point between first tier price and second tier price
second_tier_price price of electricity between second tier and third tier energy usage
secondary_voltage secondary voltage level kV
sense_node Node to be monitored for voltage control in remote sense mode
sense_object FOUR QUADRANT MODEL: name of the object the inverter is trying to mitigate th...
sensitivity LEGACY MODEL: describes how sensitive the control is to temperature excursion...
series_compensator_resistance Baseline resistance for the series compensator device - needed for NR
service_status In and out of service flag
service_status_double In and out of service flag - type double - will indiscriminately override ser...
set_pdispatch trigger to set pdispatch equal to (power_in + power_out)/2
setpoint load setpoint to track to
SEXS_mode Q-V droop function
SEXS_Q_V_droop Q-V droop slope
SEXS_Vset Voltage setpoint of QV droop
sfm_Tf Transducer time constant for simplified frequency measurement (seconds)
shading_factor Shading factor for scaling solar power to the array
shape the loadshape driving the enduse
shield_diameter The outside diameter of Tape shield in inches
shield_gmr Geometric mean radius of shielding sheath
shield_resistance Resistance of shielding sheath in ohms/mile
shield_thickness The thickness of Tape shield in inches
shunt_1 accumulator - used for debugging/interfacing only - shunt impedance on phase ...
shunt_12 accumulator - used for debugging/interfacing only - shunt impedance on phase ...
shunt_2 accumulator - used for debugging/interfacing only - shunt impedance on phase ...
shunt_A bus shunt admittance, this an accumulator only, not a output or input variabl...
shunt_AB bus shunt delta-connected admittance, this an accumulator only, not a output ...
shunt_AN bus shunt wye-connected admittance, this an accumulator only, not a output or...
shunt_B bus shunt admittance, this an accumulator only, not a output or input variabl...
shunt_BC bus shunt delta-connected admittance, this an accumulator only, not a output ...
shunt_BN bus shunt wye-connected admittance, this an accumulator only, not a output or...
shunt_C bus shunt admittance, this an accumulator only, not a output or input variabl...
shunt_CA bus shunt delta-connected admittance, this an accumulator only, not a output ...
shunt_CN bus shunt wye-connected admittance, this an accumulator only, not a output or...
shunt_impedance Shunt impedance on primary side, pu
shunt_reactance Shunt impedance on primary side, pu, imag
shunt_resistance Shunt impedance on primary side, pu, real
sigma1 intermediate variable 1 associated with synch
sigma2 intermediate variable 2 associated with synch
simulate_window_openings activates a representation of an occupant opening a window and de-activating ...
size
SOC state of charge as percentage of total capacity
SOC_0_ES Initial state of charge
SOC_ES State of charge
soc_reserve FOUR QUADRANT MODEL: The reserve state of charge of an attached battery for i...
soiling Soiling of array factor - representing dirt on array
solar_gain solar heat gains
solar_heatgain_factor product of the window area, window transmitivity, and the window exterior tra...
SOLAR_POWER_MODEL
SOLAR_TILT_MODEL solar tilt model used to compute insolation values
Solarthermal_CO2
Solarthermal_Conv_Eff
Solarthermal_emissions_CO2
Solarthermal_emissions_NOx
Solarthermal_emissions_SO2
Solarthermal_Max_Out
Solarthermal_NOx
Solarthermal_Order
Solarthermal_Out
Solarthermal_SO2
solution
source_vertex Source vertex object for reconfiguration
south_incident_solar_radiation incident solar radiation hitting the south side of the house
southeast_incident_solar_radiation incident solar radiation hitting the southeast side of the house
southwest_incident_solar_radiation incident solar radiation hitting the southwest side of the house
SOx_emission Total SOx emissions (lbs) based on fuel usage
spacing
specificheat_food
spin_mode
stable_time Time taken by the VFD to reach desired frequency (based on RPM)
stall_impedance compressor stall imepdance
stall_reactance compressor stall reactance
stall_resistance compressor stall resistance
stall_time_tracker internal stall time tracker variable
stall_voltage
standby_power standby microwave power draw (unshaped only)
start_time CHECKPOINT_VAR: Recording start time of simulation
start_voltage
state
state_change_time_delta CHECKPOINT_VAR: internal variable for state_change_time_delta
state_cooktop
state_of_charge INTERNAL BATTERY MODEL: the current state of charge of the battery
state_time CHECKPOINT_VAR: internal variable for state time
status
stored_capacity amount of capacity that is stored
strictly_radial Flag to indicate if a system is known to be strictly radial -- uses radial as...
substation_link Substation link, transformer, or regulator to measure power factor
sustained_count
switch_impedance Impedance value of the swtich when closed
switch_reactance Reactance portion of impedance value of the switch when it is closed
switch_resistance Resistance portion of impedance value of the switch when it is closed
switchA capacitor A switch open or close
switchB capacitor B switch open or close
switchC capacitor C switch open or close
sync_check_object The object reference/name of the sync_check object, which works with this syn...
system_base System base power rating for per-unit calculations
system_mode heating/cooling system operation state
system_type heating/cooling system type/options
T_coeff Maximum power temperature coefficient for module temperature correction formu...
T_D Inrush decay time constant for inrush current
t_delay the controller will wait for t_delay to take actions
t_flag
t_hold Once the controller changes the voltage set point, it will stay there for t_h...
T_mixing_valve MULTILAYER MODEL: Reference temperature to which mixing valve operate
T_nominal
t_ref_cels The referenced temperature
Ta Armature short-circuit time constant (s)
TA Exciter time constant (seconds)
Tambient
tank_diameter the diameter of the water heater tank
tank_fittings_weight The weight of the tank and fittings in pounds
tank_height the height of the water heater tank
tank_setpoint the temperature around which the water heater will heat its contents
tank_UA the UA of the tank (surface area divided by R-value)
tank_volume the volume of water in the tank when it is full
tap_A current tap position of tap A
tap_A_change_count count of all physical tap changes on phase A since beginning of simulation (p...
tap_B current tap position of tap B
tap_B_change_count count of all physical tap changes on phase B since beginning of simulation (p...
tap_C current tap position of tap C
tap_C_change_count count of all physical tap changes on phase C since beginning of simulation (p...
tap_pos_A initial tap position of phase A
tap_pos_B initial tap position of phase B
tap_pos_C initial tap position of phase C
target target object to track the load of
target_property property on the target object representing the load
TB Exciter transient gain reduction time constant (seconds)
TC Exciter transient gain reduction time constant (seconds)
Tcell
Tcontrol in heat pump operation, defines the blended temperature used for turning on a...
TcoolOn CHECKPOINT_VAR: internal variable for Tcool on in degF
Tdop d-axis open circuit time constant (s)
Tdopp d-axis open circuit subtransient time constant (s)
Tdp d-axis short circuit time constant (s)
temperature temperature of the device's controlled media (eg air temp or water temp)
Teq
Tevent
Tff DELTAMODE: the time constant of frequency measurement low pass filter in freq...
Tfreq_delay DELTAMODE: The time constant for delayed frequency seen by the inverter
thermal_integrity_level default envelope UA settings
thermal_storage_in_use logic statement for determining if energy storage is being utilized
thermal_storage_present logic statement for determining if energy storage is present
thermostat_control determine level of internal thermostatic control
thermostat_cycle_time minimum time in seconds between thermostat updates
thermostat_deadband deadband of thermostat control
thermostat_last_cycle_time last time the thermostat changed state
thermostat_mode tells the thermostat whether it is even allowed to heat or cool the house
thermostat_off_cycle_time the minimum amount of time the thermostat cycle must stay in the off state
thermostat_on_cycle_time the minimum amount of time the thermostat cycle must stay in the on state
thermostatic_control_range Range of the thermostat's control operation
third_tier_energy switching point between second tier price and third tier price
third_tier_price price of electricity when energy usage exceeds third tier energy usage
Tif DELTAMODE: time constant of first-order low-pass filter of current loop when ...
tilt_angle Tilt angle of PV array
time_cooktop_operation
time_cooktop_setting
time_delay control time delay
time_oven_operation
time_oven_setting
time_step_divider divide time step by n - single- and three- phase models
time_to_transition CHECKPOINT_VAR: internal variable for time to transition
Tlower CHECKPOINT_VAR: internal variable for Tlower
Tlower_old CHECKPOINT_VAR: internal variable for Tlower_old
Tmodule
to to_node - load node
To_prime rotor time constant
Toff
Ton
top_oil_hot_spot_temperature top-oil hottest-spot temperature, degrees C
topological_parent topological parent as per GLM configuration
torque_elec Current electrical torque output of machine
torque_mech Current mechanical torque of machine
torque_usage_method Approach for using Tmech on both types
total_capacity total storage capacity of unit
total_compressor_time CHECKPOINT_VAR: internal variable for total compressor time
total_count
total_cycle_time CHECKPOINT_VAR: internal variable for time to transition
Total_emissions_CO2
Total_emissions_NOx
Total_emissions_SO2
Total_energy_out
total_load
total_power
total_power_cooktop
total_power_oven
total_power_range
total_reactive_power Total reactive power output
total_real_power Total real power output
total_thermal_mass_per_floor_area
TotalReacPow Total reactive power output
TotalRealPow Total real power output
Tp DELTAMODE: time constant of low pass filter, P calculation
Tp_delay DELTAMODE: The time constant for delayed real power seen by the VSI droop con...
Tpf DELTAMODE: the time constant of power measurement low pass filter in frequenc...
Tq DELTAMODE: time constant of low pass filter, Q calculation
Tq_delay DELTAMODE: The time constant for delayed reactive power seen by the VSI droop...
Tqf DELTAMODE: the time constant of low pass filter in volt-var
Tqop q-axis open circuit time constant (s)
Tqopp q-axis open circuit subtransient time constant (s)
transformer_replacement_count counter of the number times the transformer has been replaced due to lifetime...
transitions
transmission_level_constant_current_load the average constant current load at nominal voltage to be posted directly to...
transmission_level_constant_impedance_load the average constant impedance load at nominal voltage to be posted directly ...
transmission_level_constant_power_load the average constant power load to be posted directly to the pw_load object
travel_distance Distance vehicle travels from home to home (round trip)
trip current time in tripped state
trip_delay
trip_time time motor can stay stalled before tripping off
triplex_connection_type Describes how the motor will connect to the triplex devices
triplex_neutral_1_value
triplex_neutral_2_value
Tstall stall time
Tupper CHECKPOINT_VAR: internal variable for Tupper
Tupper_old CHECKPOINT_VAR: internal variable for Tupper_old
turbine_height Describes the height of the wind turbine hub above the ground
Turbine_implementation Wind turbine implementation based on Generic Power Curve
Turbine_Model Generic model for a 1
turn_fan_on CHECKPOINT_VAR: internal variable for turn fan on
turns_ratio_1 Debug variable - Turns ratio for phase 1 (triplex) series compensator equival...
turns_ratio_2 Debug variable - Turns ratio for phase 2 (triplex) series compensator equival...
turns_ratio_A Debug variable - Turns ratio for phase A series compensator equivalent
turns_ratio_B Debug variable - Turns ratio for phase B series compensator equivalent
turns_ratio_C Debug variable - Turns ratio for phase C series compensator equivalent
Tv DELTAMODE: time constant of low pass filter, V calculation
Tvf DELTAMODE: the time constant of low pass filter in volt-var
Tvol_delay DELTAMODE: The time constant for delayed voltage seen by the inverter
Tw_old CHECKPOINT_VAR: internal variable for Tw_old
Type Defines regulator type
type lighting type (affects power_factor)
UA
ugd_pu_A DELTAMODE: terminal voltage of grid-following inverter, d-axis, phase A
ugd_pu_B DELTAMODE: terminal voltage of grid-following inverter, d-axis, phase B
ugd_pu_C DELTAMODE: terminal voltage of grid-following inverter, d-axis, phase C
ugq_pu_A DELTAMODE: terminal voltage of grid-following inverter, q-axis, phase A
ugq_pu_B DELTAMODE: terminal voltage of grid-following inverter, q-axis, phase B
ugq_pu_C DELTAMODE: terminal voltage of grid-following inverter, q-axis, phase C
under_freq_high_cutout DELTAMODE: UF2 set point for IEEE 1547a
under_freq_high_disconnect_time DELTAMODE: UF2 clearing time for IEEE1547a
under_freq_low_band_viol_time CHECKPOINT_VAR: UF1 violation accumulator
under_freq_low_cutout DELTAMODE: UF1 set point for IEEE 1547a
under_freq_low_disconnect_time DELTAMODE: UF1 clearing time for IEEE 1547a
under_voltage_high_cutout High value of low voltage threshold for undervoltage
under_voltage_high_disconnect_time Highest voltage clearing time for undervoltage
under_voltage_high_viol_time CHECKPOINT_VAR: Highest low voltage threshold violation accumulator
under_voltage_low_cutout Lowest voltage threshold for undervoltage
under_voltage_low_disconnect_time Lowest voltage clearing time for undervoltage
under_voltage_lowest_viol_time CHECKPOINT_VAR: Lowest low voltage threshold violation accumulator
under_voltage_middle_cutout Middle-lowest voltage threshold for undervoltage
under_voltage_middle_disconnect_time Middle-lowest voltage clearing time for undervoltage
under_voltage_middle_viol_time CHECKPOINT_VAR: Middle low voltage threshold violation accumulator
upper_heating_element_state MULTILAYER MODEL: The state of the upper heating element in the tank
upper_tank_deadband MULTILAYER_MODEL: The deadband for the upper heating element thermostat in th...
upper_tank_setpoint MULTILAYER_MODEL: The setpoint for the upper heating element thermostat in th...
upper_tank_temperature MULTILAYER_MODEL: The water temperature for the upper heating element thermos...
upper_voltage_limit Upper voltage limit for the reconfiguration validity checks - per unit
use_internal_battery_model Enables the INTERNAL BATTERY MODEL
use_latent_heat Boolean for using the heat latency of the air to the humidity when cooling
use_multipoint_efficiency FOUR QUADRANT MODEL: boolean to used the multipoint efficiency curve for the ...
use_thermal_model boolean to enable use of thermal model
uv_relay_install is under-voltage relay protection installed on this motor
uv_relay_trip_time time low-voltage condition must exist for under-voltage protection to trip
uv_relay_trip_V pu minimum voltage before under-voltage relay trips
V1 FOUR QUADRANT MODEL: voltage point 1 in volt/var curve
V2 FOUR QUADRANT MODEL: voltage point 2 in volt/var curve
V3 FOUR QUADRANT MODEL: voltage point 3 in volt/var curve
V4 FOUR QUADRANT MODEL: voltage point 4 in volt/var curve
V_angle_A DELTAMODE: Internal angle of grid-forming source, phase A
V_angle_B DELTAMODE: Internal angle of grid-forming source, phase B
V_angle_C DELTAMODE: Internal angle of grid-forming source, phase C
V_base FOUR QUADRANT MODEL: The base voltage on the grid side of the inverter
V_bypass_max_pu the upper limit voltage to bypass compensator
V_bypass_min_pu the lower limit voltage to bypass compensator
V_error Make sure the voltage can go back to nominal
V_ES_pu ES terminal voltage, per unit
V_In DC voltage
V_Internal LEGACY MODEL: the internal voltage of the battery
V_Max LEGACY MODEL: the maximum terminal voltage of the battery
v_measure DELTAMODE: filtered voltage for grid-forming inverter
V_Out LEGACY MODEL: the AC voltage at the terminals of the battery
V_Rated
V_set0 DELTAMODE: The voltage setpoint of grid-following Q-V droop control
V_set1 DELTAMODE: The voltage setpoint of grid-following Q-V droop control
V_set2 DELTAMODE: The voltage setpoint of grid-following Q-V droop control
V_set_droop DELTAMODE: The voltage setpoint of droop control
VA_Out LEGACY MODEL: the power output of the battery
vadd Delta Vset
vadd_a Delta Vset before going into bound check
value_Circuit_V_A CHECKPOINT_VAR: internal variable for value_Circuit_V[0]
value_Circuit_V_B CHECKPOINT_VAR: internal variable for value_Circuit_V[1]
value_Circuit_V_C CHECKPOINT_VAR: internal variable for value_Circuit_V[2]
value_Line12 CHECKPOINT_VAR: internal variable for value_Line12
value_Line_I_A CHECKPOINT_VAR: internal variable for value_Line_I[0]
value_Line_I_B CHECKPOINT_VAR: internal variable for value_Line_I[1]
value_Line_I_C CHECKPOINT_VAR: internal variable for value_Line_I[2]
value_MeterStatus CHECKPOINT_VAR: internal variable for value MeterStatus
value_Tout CHECKPOINT_VAR: internal variable for value_Tout
Vapu CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi...
VAr_deadband The deadband between VAr_set_high and VAr_set_low
VAr_deadband_center The VAr deadband center
VAr_set_high high VAR set point for VAR control (turn off)
VAr_set_low low VAR set point for VAR control (turn on)
variation_mean Mean of normal variation of schedule variation
variation_std_dev Standard deviation of normal variation of schedule times
variation_trip_mean Mean of normal variation of trip distance variation
variation_trip_std_dev Standard deviation of normal variation of trip distance
Vas motor phase-a stator-to-ground voltage
Vbase_ES Rated voltage of ES
Vbpu CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi...
Vbrk Compressor motor breakdown voltage
Vbs motor phase-b stator-to-ground voltage
Vcpu CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi...
Vcs motor phase-c stator-to-ground voltage
Vdc LEGACY MODEL: DC voltage
Vdc_min_pu DELTAMODE: The reference voltage of the Vdc_min controller
Vdc_pu DELTAMODE: dc bus voltage of PV panel when using grid-forming PV Inverter
vehicle_index Index of vehicles in file this particular vehicle's data
vehicle_location
vehicle_type
vfd_state Current state of the VFD
VFlag DELTAMODE: Voltage flag to choose between PI control or direct control
Vinit Initial assumed voltage value of connected terminal
VintRotated d-q rotated Vint voltage state variable
virtual_resistance_correction DELTAMODE: Boolean used to indicate whether inverter applies virtual resistan...
Voc
Voc_Max
Voc_temp_coeff
volt_A_ang_deg_diff Measurement property: Difference of phase A voltage angle in degree
volt_A_diff Measurement property: Magnitude of phase A voltage phasor difference in volt
volt_A_diff_pu Measurement property: Magnitude of phase A voltage phasor difference in pu
volt_A_mag_diff Measurement property: Difference of phase A voltage magnitude in volt
volt_A_mag_diff_noabs_pu Measurement property: Difference of phase A voltage magnitude in pu without a...
volt_A_mag_diff_pu Measurement property: Difference of phase A voltage magnitude in pu
volt_B_ang_deg_diff Measurement property: Difference of phase B voltage angle in degree
volt_B_diff Measurement property: Magnitude of phase B voltage phasor difference in volt
volt_B_diff_pu Measurement property: Magnitude of phase B voltage phasor difference in pu
volt_B_mag_diff Measurement property: Difference of phase B voltage magnitude in volt
volt_B_mag_diff_noabs_pu Measurement property: Difference of phase B voltage magnitude in pu without a...
volt_B_mag_diff_pu Measurement property: Difference of phase B voltage magnitude in pu
volt_C_ang_deg_diff Measurement property: Difference of phase C voltage angle in degree
volt_C_diff Measurement property: Magnitude of phase C voltage phasor difference in volt
volt_C_diff_pu Measurement property: Magnitude of phase C voltage phasor difference in pu
volt_C_mag_diff Measurement property: Difference of phase C voltage magnitude in volt
volt_C_mag_diff_noabs_pu Measurement property: Difference of phase C voltage magnitude in pu without a...
volt_C_mag_diff_pu Measurement property: Difference of phase C voltage magnitude in pu
volt_compare_mode Determines which voltage difference calculation approach is used
volt_var DELTAMODE: Boolean used to indicate whether inverter volt-var droop is includ...
volt_var_control_lockout FOUR QUADRANT QUADRANT MODEL: the lockout time between volt/var actions
volt_var_droop DELTAMODE: Q-V droop gain in volt-var
volt_var_sched
voltage_1 bus voltage, phase 1 to ground
voltage_12 bus voltage, phase 1 to 2
voltage_1N bus voltage, phase 1 to N
voltage_2 bus voltage, phase 2 to ground
voltage_2N bus voltage, phase 2 to N
voltage_A bus voltage, Phase A to ground
voltage_AB line voltages, Phase AB
voltage_angle_tolerance tolerance in degrees for the difference in voltage angles - used in SEP_DIFF ...
voltage_B bus voltage, Phase B to ground
voltage_BC line voltages, Phase BC
voltage_C bus voltage, Phase C to ground
voltage_CA line voltages, Phase CA
voltage_convergence Convergence criterion for voltage changes (if exciter present) to determine w...
voltage_convergence_criterion Max voltage update for grid-forming inverters to return to QSTS
voltage_deadband The deadband between voltage_set_high and voltage_set_low
voltage_deadband_center The voltage deadband center
voltage_factor the voltage change factor (pu)
voltage_magnitude_convergence_enabled Uses voltage_convergence to determine if an exit of deltamode is needed - onl...
voltage_magnitude_tolerance tolerance in Volts for the difference in voltage magnitudes - used in SEP_DIF...
voltage_magnitude_tolerance_pu tolerance in per-unit for the difference in voltage magnitudes - used in SEP_...
voltage_measurements List of voltage measurement devices, separated by commas
voltage_N bus voltage, phase N to ground
voltage_set_high Turn off if voltage is above this set point
voltage_set_low Turns on if voltage is below this set point
voltage_tolerance voltage_tolerance in Volts - used in MAG_DIFF mode - prioritized over voltage...
voltage_tolerance_pu voltage_tolerance in per-unit - used in MAG_DIFF mode
voltage_update_tolerance Largest absolute between vset_X and measured voltage that won't force a reite...
Vref Exciter CVR control voltage reference value
Vref_SEXS Voltage reference for SEXS exciter
Vrotor_A COP: Induction generator induced voltage on phase A in p
Vrotor_B COP: Induction generator induced voltage on phase B in p
Vrotor_C COP: Induction generator induced voltage on phase C in p
Vrst Voltage at which motor can restart
Vs motor voltage
vset vset input to AVR controls (per-unit)
Vset Vset input to AVR controls (per-unit)
vset_1 Voltage magnitude reference for phase 1 of a triplex system
vset_1_0 Voltage magnitude reference for phase 1 of a triplex system
vset_2 Voltage magnitude reference for phase 2 of a tryplex system
vset_2_0 Voltage magnitude reference for phase 2 of a tryplex system
vset_A Voltage magnitude reference for phase A
vset_A_0 Voltage magnitude set point for phase A, changed by the player
vset_B Voltage magnitude reference for phase B
vset_B_0 Voltage magnitude set point for phase B, changed by the player
vset_C Voltage magnitude reference for phase C
vset_C_0 Voltage magnitude set point for phase C, changed by the player
vset_delta_MAX Maximum delta Vset limit
vset_delta_MIN Minimum delta Vset limit
Vset_QV_droop Voltage setpoint of QV droop
VSI_freq VSI frequency
VSI_mode VSI MODEL: Selects VSI mode for either isochronous or droop one
VSI_Rfilter VSI filter resistance (p
VSI_Xfilter VSI filter inductance (p
Vstall Compressor stall threshold voltage
Vstallbrk Intersection point for power curve and power stall curve - calculated
Vterm_max Upper voltage limit for super-second (p
Vterm_min Lower voltage limit for super-second (p
VW_P1 FOUR QUADRANT MODEL: Power limit at VW_P1 (e
VW_P2 FOUR QUADRANT MODEL: Power limit at VW_P2 (e
VW_V1 FOUR QUADRANT MODEL: Voltage at which power limiting begins (e
VW_V2 FOUR QUADRANT MODEL: Voltage at which power limiting ends
w_lim DELTAMODE: saturation limit of Pmax controller
w_ref w_ref input to governor controls (rad/s) - takes priority over wref
wash_mode
water_demand the hot water draw from the water heater
water_demand_old CHECKPOINT_VAR: internal variable for previous water demand
waterheater_model the water heater model to use
waterheater_power the current power draw from the fortran water heater
wb base speed
weather
west_incident_solar_radiation incident solar radiation hitting the west side of the house
Wind_CO2
Wind_Conv_Eff
Wind_emissions_CO2
Wind_emissions_NOx
Wind_emissions_SO2
Wind_Max_Out
Wind_NOx
Wind_Order
Wind_Out
Wind_SO2
wind_speed
Wind_Speed Wind speed at 5-15m level (typical measurement height)
wind_speed_adjusted Speed of wind at hub height
wind_speed_hub_ht Wind speed at hub height
Wind_speed_source The climate data specifying the wind speed
winding_hot_spot_temperature winding hottest-spot temperature, degrees C
window_constant_coefficient constant coefficient for describing function between low and high temperature...
window_exterior_transmission_coefficient coefficient for the amount of energy that passes through window
window_first_time_through CHECKPOINT_VAR: internal variable for window first time through
window_frame type of window frame
window_high_temperature_cutoff highest temperature at which the window opening might occur
window_linear_coefficient linear coefficient for describing function between low and high temperature c...
window_low_temperature_cutoff lowest temperature at which the window opening might occur
window_quadratic_coefficient quadratic coefficient for describing function between low and high temperatur...
window_shading transmission coefficient through window due to glazing
window_temperature_delta change in outdoor temperature required to update the window opening model
window_wall_ratio ratio of window area to wall area
work_charging_available Charging available when at work
work_dist
wref wref input to governor controls (per-unit)
write_per_unit Output the quantities as per-unit values
write_reliability Flag indicating whether reliabililty information will be written into JSON fi...
write_system_info Flag indicating whether system information will be written into JSON file or ...
ws system speed
ws_maxcp COP: Wind speed at which generator reaches maximum Cp
ws_rated COP: Rated wind speed for generator operation
WSadj Speed of wind at hub height
WT_is_connected Internal flag that indicates a wind turbine child is connected
X0 Zero sequence impedance (p
x0_root_rt Set the initial guess at this extra percentage of the absolute x value at the...
X2 Negative sequence impedance (p
x_cvr1 Exciter state variable - CVR mode
x_cvr2 Exciter state variable - CVR mode
X_magnetic COP: Induction generator primary core reactance in p
X_rotor COP: Induction generator primary rotor reactance in p
X_stator COP: Induction generator primary stator reactance in p
xb Exciter state variable
Xc_run running capacitor reactance - single-phase model
Xc_start starting capacitor reactance - single-phase model
Xd d-axis reactance (p
Xd_prime d-axis reactance - single-phase model
Xdp d-axis transient reactance (p
Xdpp d-axis subtransient reactance (p
xe Exciter state variable
Xfilter DELTAMODE: per-unit values of inverter filter
Xg COP: Synchronous generator grounding reactance in p
Xl Leakage reactance (p
Xm magnetizing reactance
Xq q-axis reactance (p
Xq_prime q-axis reactance - single-phase model
Xqp q-axis transient reactance (p
Xqpp q-axis subtransient reactance (p
Xr rotor reactance
Xs stator leakage reactance - three-phase model
z11
z12
z13
z21
z22
z23
z31
z32
z33
zero_sequence_voltage The zero sequence representation of the voltage for the substation object
Zp
Zp_H
Zp_R
Zp_S
Zp_T
Zp_W
Zq
Zq_H
Zq_R
Zq_S
Zq_T
Zq_W

Enumerations

Enumeration Description
AdditionalControls AdditionalControls enumeration
AuxiliaryStrategy AuxiliaryStrategy enumeration
AuxiliarySystemType AuxiliarySystemType enumeration
BatteryState BatteryState enumeration
BatteryType BatteryType enumeration
BillMode BillMode enumeration
Busflags Busflags enumeration
Bustype Bustype enumeration
ChargerType ChargerType enumeration
CheckMode CheckMode enumeration
Condition Condition enumeration
ConnectedHouseAssumedMode ConnectedHouseAssumedMode enumeration
ConnectType ConnectType enumeration
ContactorState ContactorState enumeration
Control Control enumeration
ControlLevel ControlLevel enumeration
ControlMethod ControlMethod enumeration
ControlMode ControlMode enumeration
ControlMode0 ControlMode0 enumeration
ControlMode1 ControlMode1 enumeration
ControlMode2 ControlMode2 enumeration
ControlMode3 ControlMode3 enumeration
CoolantType CoolantType enumeration
CoolingCapCurve CoolingCapCurve enumeration
CoolingCopCurve CoolingCopCurve enumeration
CoolingSystemType CoolingSystemType enumeration
CoolingType CoolingType enumeration
CtPhase CtPhase enumeration
CurrentTankStatus CurrentTankStatus enumeration
CvrMode CvrMode enumeration
DefrostCriterion DefrostCriterion enumeration
DesiredMotorState DesiredMotorState enumeration
DischargeScheduleType DischargeScheduleType enumeration
DynamicModelMode DynamicModelMode enumeration
ExciterType ExciterType enumeration
ExternalPfMode ExternalPfMode enumeration
FanType FanType enumeration
FlowDirection FlowDirection enumeration
FourQuadrantControlMode FourQuadrantControlMode enumeration
FrequencyMeasureType FrequencyMeasureType enumeration
GeneratorMode GeneratorMode enumeration
GeneratorStatus GeneratorStatus enumeration
GenMode GenMode enumeration
GenStatus GenStatus enumeration
GenType GenType enumeration
GfaTripMethod GfaTripMethod enumeration
GlassType GlassType enumeration
GlazingLayers GlazingLayers enumeration
GlazingTreatment GlazingTreatment enumeration
GovernorType GovernorType enumeration
GridFollowingMode GridFollowingMode enumeration
GridFormingMode GridFormingMode enumeration
HcMode HcMode enumeration
HeatingCapCurve HeatingCapCurve enumeration
HeatingCopCurve HeatingCopCurve enumeration
HeatingSystemType HeatingSystemType enumeration
HeatMode HeatMode enumeration
Ieee1547Status Ieee1547Status enumeration
Ieee1547TripMethod Ieee1547TripMethod enumeration
Ieee1547Version Ieee1547Version enumeration
IncludeSolarQuadrant IncludeSolarQuadrant enumeration
InrushIntegrationMethod InrushIntegrationMethod enumeration
InrushIntegrationMethodCapacitance InrushIntegrationMethodCapacitance enumeration
InrushIntegrationMethodInductance InrushIntegrationMethodInductance enumeration
InstallType InstallType enumeration
InverterManufacturer InverterManufacturer enumeration
InverterType InverterType enumeration
J2894TripMethod J2894TripMethod enumeration
LastSystemMode LastSystemMode enumeration
LoadClass LoadClass enumeration
LoadFollowStatus LoadFollowStatus enumeration
LoadPriority LoadPriority enumeration
LoadState LoadState enumeration
Location Location enumeration
LowerHeatingElementState LowerHeatingElementState enumeration
MagnetizationLocation MagnetizationLocation enumeration
MeterType MeterType enumeration
Mode Mode enumeration
MotorEfficiency MotorEfficiency enumeration
MotorModel MotorModel enumeration
MotorOperationType MotorOperationType enumeration
MotorStatus MotorStatus enumeration
MsgMode MsgMode enumeration
OperatingMode OperatingMode enumeration
Operation Operation enumeration
Orientation Orientation enumeration
PanelType PanelType enumeration
PFDroopSettingMode PFDroopSettingMode enumeration
PfPhase PfPhase enumeration
PfReg PfReg enumeration
PfRegStatus PfRegStatus enumeration
Phase1State Phase1State enumeration
Phase2State Phase2State enumeration
PhaseAState PhaseAState enumeration
PhaseAStatus PhaseAStatus enumeration
PhaseBState PhaseBState enumeration
PhaseBStatus PhaseBStatus enumeration
PhaseCState PhaseCState enumeration
PhaseCStatus PhaseCStatus enumeration
Phases Phases enumeration
PhasesConnected PhasesConnected enumeration
Placement Placement enumeration
PowerType PowerType enumeration
PtPhase PtPhase enumeration
RechargeScheduleType RechargeScheduleType enumeration
RectifierType RectifierType enumeration
ReferencePhase ReferencePhase enumeration
ReOverride ReOverride enumeration
RepairDistType RepairDistType enumeration
ReverseFlowControl ReverseFlowControl enumeration
RfbSize RfbSize enumeration
ServiceStatus ServiceStatus enumeration
SexsMode SexsMode enumeration
SolarPowerModel SolarPowerModel enumeration
SolarTiltModel SolarTiltModel enumeration
Solution Solution enumeration
SpinMode SpinMode enumeration
State State enumeration
StateCooktop StateCooktop enumeration
Status Status enumeration
Switcha Switcha enumeration
Switchb Switchb enumeration
Switchc Switchc enumeration
SystemMode SystemMode enumeration
SystemType SystemType enumeration
ThermalIntegrityLevel ThermalIntegrityLevel enumeration
ThermostatControl ThermostatControl enumeration
ThermostatMode ThermostatMode enumeration
TorqueUsageMethod TorqueUsageMethod enumeration
TriplexConnectionType TriplexConnectionType enumeration
TurbineImplementation TurbineImplementation enumeration
TurbineModel TurbineModel enumeration
Type Type enumeration
UpperHeatingElementState UpperHeatingElementState enumeration
UvRelayInstall UvRelayInstall enumeration
VehicleLocation VehicleLocation enumeration
VehicleType VehicleType enumeration
VfdState VfdState enumeration
VoltCompareMode VoltCompareMode enumeration
VsiMode VsiMode enumeration
WashMode WashMode enumeration
WaterheaterModel WaterheaterModel enumeration
WindowFrame WindowFrame enumeration
WindSpeedSource WindSpeedSource enumeration

Types

Type Description
Boolean A binary (true or false) value
Curie a compact URI
Date a date (year, month and day) in an idealized calendar
DateOrDatetime Either a date or a datetime
Datetime The combination of a date and time
Decimal A real number with arbitrary precision that conforms to the xsd:decimal speci...
Double A real number that conforms to the xsd:double specification
Float A real number that conforms to the xsd:float specification
Integer An integer
Jsonpath A string encoding a JSON Path
Jsonpointer A string encoding a JSON Pointer
Ncname Prefix part of CURIE
Nodeidentifier A URI, CURIE or BNODE that represents a node in a model
Objectidentifier A URI or CURIE that represents an object in the model
Sparqlpath A string encoding a SPARQL Property Path
String A character string
Time A time object represents a (local) time of day, independent of any particular...
Uri a complete URI
Uriorcurie a URI or a CURIE

Subsets

Subset Description