Skip to content

Class: RegulatorConfiguration

Copyright (C) 2008 Battelle Memorial Institute

@file regulator_configuration.cpp

@addtogroup regulator_configuration

@ingroup regulator

@{

__

Inherits from: powerflow_library

__

Type: Configuration (physical asset template)

__

Note: Inherits from powerflow_library (not in powerflow module)

URI: glm:RegulatorConfiguration

 classDiagram
    class RegulatorConfiguration
    click RegulatorConfiguration href "../RegulatorConfiguration/"
      GlmObject <|-- RegulatorConfiguration
        click GlmObject href "../GlmObject/"

      RegulatorConfiguration : band_center

      RegulatorConfiguration : band_width

      RegulatorConfiguration : compensator_r_setting_A

      RegulatorConfiguration : compensator_r_setting_B

      RegulatorConfiguration : compensator_r_setting_C

      RegulatorConfiguration : compensator_x_setting_A

      RegulatorConfiguration : compensator_x_setting_B

      RegulatorConfiguration : compensator_x_setting_C

      RegulatorConfiguration : connect_type





        RegulatorConfiguration --> "0..1" ConnectType : connect_type
        click ConnectType href "../ConnectType/"



      RegulatorConfiguration : Control

      RegulatorConfiguration : control_level

      RegulatorConfiguration : CT_phase

      RegulatorConfiguration : current_transducer_ratio

      RegulatorConfiguration : dwell_time

      RegulatorConfiguration : flags

      RegulatorConfiguration : groupid

      RegulatorConfiguration : in_svc

      RegulatorConfiguration : latitude

      RegulatorConfiguration : longitude

      RegulatorConfiguration : lower_taps

      RegulatorConfiguration : name

      RegulatorConfiguration : out_svc

      RegulatorConfiguration : parent

      RegulatorConfiguration : power_transducer_ratio

      RegulatorConfiguration : PT_phase

      RegulatorConfiguration : raise_taps

      RegulatorConfiguration : rank

      RegulatorConfiguration : regulation

      RegulatorConfiguration : reverse_flow_control

      RegulatorConfiguration : tap_pos_A

      RegulatorConfiguration : tap_pos_B

      RegulatorConfiguration : tap_pos_C

      RegulatorConfiguration : time_delay

      RegulatorConfiguration : Type

Inheritance

Slots

Name Cardinality and Range Description Inheritance
connect_type 0..1
ConnectType
Designation of connection style direct
band_center 0..1
Float
band center setting of regulator control direct
band_width 0..1
Float
band width setting of regulator control direct
time_delay 0..1
Float
mechanical time delay between tap changes direct
dwell_time 0..1
Float
time delay before a control action of regulator control direct
raise_taps 0..1
Integer
number of regulator raise taps, or the maximum raise voltage tap position direct
lower_taps 0..1
Integer
number of regulator lower taps, or the minimum lower voltage tap position direct
current_transducer_ratio 0..1
Float
primary rating of current transformer direct
power_transducer_ratio 0..1
Float
potential transformer rating direct
compensator_r_setting_A 0..1
Float
Line Drop Compensation R setting of regulator control (in volts) on Phase A direct
compensator_r_setting_B 0..1
Float
Line Drop Compensation R setting of regulator control (in volts) on Phase B direct
compensator_r_setting_C 0..1
Float
Line Drop Compensation R setting of regulator control (in volts) on Phase C direct
compensator_x_setting_A 0..1
Float
Line Drop Compensation X setting of regulator control (in volts) on Phase A direct
compensator_x_setting_B 0..1
Float
Line Drop Compensation X setting of regulator control (in volts) on Phase B direct
compensator_x_setting_C 0..1
Float
Line Drop Compensation X setting of regulator control (in volts) on Phase C direct
CT_phase 0..1
String
phase(s) monitored by CT direct
PT_phase 0..1
String
phase(s) monitored by PT direct
regulation 0..1
Float
regulation of voltage regulator in % direct
control_level 0..1
String
Designates whether control is on per-phase or banked level direct
Control 0..1
String
Type of control used for regulating voltage direct
reverse_flow_control 0..1
String
Type of control used when power is flowing in reverse through the regulator direct
Type 0..1
String
Defines regulator type direct
tap_pos_A 0..1
Integer
initial tap position of phase A direct
tap_pos_B 0..1
Integer
initial tap position of phase B direct
tap_pos_C 0..1
Integer
initial tap position of phase C direct
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: no CIM template, so no class of its own; its values go on the VoltageRegulator, RatioTapChanger and TapChangerControl of every regulator that names it. Export: written from the VoltageRegulator's tap changer and its control as _config.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:RegulatorConfiguration
native glm:RegulatorConfiguration
close cim:RatioTapChanger, cim:TapChangerControl, cim:VoltageRegulator

LinkML Source

Direct

name: regulator_configuration
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file regulator_configuration.cpp

  @addtogroup regulator_configuration

  @ingroup regulator

  @{


  Inherits from: powerflow_library


  Type: Configuration (physical asset template)


  Note: Inherits from powerflow_library (not in powerflow module)'
comments:
- 'Import: no CIM template, so no class of its own; its values go on the VoltageRegulator,
  RatioTapChanger and TapChangerControl of every regulator that names it. Export:
  written from the VoltageRegulator''s tap changer and its control as <regulator>_config.'
from_schema: https://gridlabd.org/schema/glm
close_mappings:
- cim:RatioTapChanger
- cim:TapChangerControl
- cim:VoltageRegulator
is_a: glm_object
attributes:
  connect_type:
    name: connect_type
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: connect_type
    description: Designation of connection style
    comments:
    - 'Import: WYE_WYE only (every AutoTransformerEnd wye, grounded); any other raises.
      Export: always WYE_WYE.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    related_mappings:
    - cim:TransformerEnd.grounded
    rank: 1000
    domain_of:
    - regulator_configuration
    - transformer_configuration
    range: ConnectType
    required: false
  band_center:
    name: band_center
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: band_center[V]
    description: band center setting of regulator control
    comments:
    - 'Import: TapChangerControl.targetValue (V), primary volts; on LINE_DROP_COMP
      x power_transducer_ratio. Export: the target (V), over ptRatio on LINE_DROP_COMP;
      unset when the control is disabled.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:RegulatingControl.targetValue
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  band_width:
    name: band_width
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: band_width[V]
    description: band width setting of regulator control
    comments:
    - 'Import: TapChangerControl.targetDeadband (V), the full band, as band_center.
      Export: the deadband (V), likewise.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:RegulatingControl.targetDeadband
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  time_delay:
    name: time_delay
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: time_delay[s]
    description: mechanical time delay between tap changes
    comments:
    - 'Import: RatioTapChanger.initialDelay and subsequentDelay (s) = dwell_time +
      time_delay. Export: see dwell_time.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.initialDelay
    - cim:TapChanger.subsequentDelay
    domain_of:
    - capacitor
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: s
  dwell_time:
    name: dwell_time
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: dwell_time[s]
    description: time delay before a control action of regulator control
    comments:
    - 'Import: with time_delay. Export: the initialDelay (s).'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.initialDelay
    - cim:TapChanger.subsequentDelay
    domain_of:
    - capacitor
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: s
  raise_taps:
    name: raise_taps
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: raise_taps
    description: number of regulator raise taps, or the maximum raise voltage tap
      position
    comments:
    - 'Import: RatioTapChanger.highStep, also the stepVoltageIncrement divisor; 0
      raises. Export: highStep - neutralStep.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    exact_mappings:
    - cim:TapChanger.highStep
    rank: 1000
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  lower_taps:
    name: lower_taps
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: lower_taps
    description: number of regulator lower taps, or the minimum lower voltage tap
      position
    comments:
    - 'Import: RatioTapChanger.lowStep = -lower_taps; 0 raises. Export: neutralStep
      - lowStep.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.lowStep
    rank: 1000
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  current_transducer_ratio:
    name: current_transducer_ratio
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_transducer_ratio[pu]
    description: primary rating of current transformer
    comments:
    - 'Import: RatioTapChanger.ctRatio, and the line drop''s CT ratio. Export: ctRatio.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    exact_mappings:
    - cim:TapChanger.ctRatio
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: pu
  power_transducer_ratio:
    name: power_transducer_ratio
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_transducer_ratio[pu]
    description: potential transformer rating
    comments:
    - 'Import: TapChangerControl.ptRatio and RatioTapChanger.ptRatio. Export: ptRatio.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    exact_mappings:
    - cim:RegulatingControl.ptRatio
    - cim:TapChanger.ptRatio
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: pu
  compensator_r_setting_A:
    name: compensator_r_setting_A
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_r_setting_A[V]
    description: Line Drop Compensation R setting of regulator control (in volts)
      on Phase A
    comments:
    - 'Import: TapChangerControl.lineDropR (ohm) = the setting x power_transducer_ratio
      / current_transducer_ratio; needs both ratios. Export: lineDropR x ctRatio /
      ptRatio on phase A.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropR
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_r_setting_B:
    name: compensator_r_setting_B
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_r_setting_B[V]
    description: Line Drop Compensation R setting of regulator control (in volts)
      on Phase B
    comments:
    - 'Import: TapChangerControl.lineDropR (ohm) = the setting x power_transducer_ratio
      / current_transducer_ratio; needs both ratios. Export: lineDropR x ctRatio /
      ptRatio on phase B.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropR
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_r_setting_C:
    name: compensator_r_setting_C
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_r_setting_C[V]
    description: Line Drop Compensation R setting of regulator control (in volts)
      on Phase C
    comments:
    - 'Import: TapChangerControl.lineDropR (ohm) = the setting x power_transducer_ratio
      / current_transducer_ratio; needs both ratios. Export: lineDropR x ctRatio /
      ptRatio on phase C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropR
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_x_setting_A:
    name: compensator_x_setting_A
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_x_setting_A[V]
    description: Line Drop Compensation X setting of regulator control (in volts)
      on Phase A
    comments:
    - 'Import: TapChangerControl.lineDropX (ohm), as the r setting. Export: lineDropX
      x ctRatio / ptRatio on phase A.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropX
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_x_setting_B:
    name: compensator_x_setting_B
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_x_setting_B[V]
    description: Line Drop Compensation X setting of regulator control (in volts)
      on Phase B
    comments:
    - 'Import: TapChangerControl.lineDropX (ohm), as the r setting. Export: lineDropX
      x ctRatio / ptRatio on phase B.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropX
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_x_setting_C:
    name: compensator_x_setting_C
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_x_setting_C[V]
    description: Line Drop Compensation X setting of regulator control (in volts)
      on Phase C
    comments:
    - 'Import: TapChangerControl.lineDropX (ohm), as the r setting. Export: lineDropX
      x ctRatio / ptRatio on phase C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropX
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  CT_phase:
    name: CT_phase
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: CT_phase
    description: phase(s) monitored by CT
    comments:
    - 'Import: BANK: the phase whose compensator setting is read, which must be PT_phase;
      INDIVIDUAL: ignored. Export: BANK: the monitored phase, else its first.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    related_mappings:
    - cim:RegulatingControl.monitoredPhase
    rank: 1000
    domain_of:
    - regulator_configuration
    range: string
    required: false
  PT_phase:
    name: PT_phase
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: PT_phase
    description: phase(s) monitored by PT
    comments:
    - 'Import: BANK: TapChangerControl.monitoredPhase; INDIVIDUAL: ignored. Export:
      BANK: the monitored phase, else its first.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    related_mappings:
    - cim:RegulatingControl.monitoredPhase
    rank: 1000
    domain_of:
    - regulator_configuration
    range: string
    required: false
  regulation:
    name: regulation
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: regulation
    description: regulation of voltage regulator in %
    comments:
    - 'Import: stepVoltageIncrement (percent) = regulation / raise_taps; 0 raises
      unless MANUAL. Export: stepVoltageIncrement x raise_taps (per unit).'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:RatioTapChanger.stepVoltageIncrement
    rank: 1000
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: pu
  control_level:
    name: control_level
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: control_level
    description: Designates whether control is on per-phase or banked level
    comments:
    - 'Import: INDIVIDUAL (default) is a unit per wired phase, BANK one gang unit.
      Export: BANK for one VoltageRegulator alone, else INDIVIDUAL.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    domain_of:
    - capacitor
    - regulator_configuration
    range: string
    required: false
  Control:
    name: Control
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Control
    description: Type of control used for regulating voltage
    comments:
    - 'Import: MANUAL (default) is enabled = controlEnabled = false; OUTPUT_VOLTAGE
      and LINE_DROP_COMP true, lineDropCompensation on LINE_DROP_COMP only; REMOTE_NODE
      on the regulator''s own output as OUTPUT_VOLTAGE. Export: MANUAL when the control
      is disabled or absent, LINE_DROP_COMP with line drop compensation, else OUTPUT_VOLTAGE.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:AutomationFunction.enabled
    - cim:TapChangerControl.lineDropCompensation
    - cim:TapChanger.controlEnabled
    rank: 1000
    domain_of:
    - regulator_configuration
    range: string
    required: false
  reverse_flow_control:
    name: reverse_flow_control
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reverse_flow_control
    description: Type of control used when power is flowing in reverse through the
      regulator
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    rank: 1000
    domain_of:
    - regulator_configuration
    range: string
    required: false
  Type:
    name: Type
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Type
    description: Defines regulator type
    comments:
    - 'Import: A is typeA, B is typeB (default B). Export: B for typeB, else A.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    exact_mappings:
    - cim:VoltageRegulator.construction
    rank: 1000
    domain_of:
    - regulator_configuration
    range: string
    required: false
  tap_pos_A:
    name: tap_pos_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: tap_pos_A
    description: initial tap position of phase A
    comments:
    - 'Import: RatioTapChanger.step of phase A''s unit unless the regulator sets tap_A;
      default 0. Export: step - neutralStep on phase A.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.step
    rank: 1000
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  tap_pos_B:
    name: tap_pos_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: tap_pos_B
    description: initial tap position of phase B
    comments:
    - 'Import: RatioTapChanger.step of phase B''s unit unless the regulator sets tap_B;
      default 0. Export: step - neutralStep on phase B.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.step
    rank: 1000
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  tap_pos_C:
    name: tap_pos_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: tap_pos_C
    description: initial tap position of phase C
    comments:
    - 'Import: RatioTapChanger.step of phase C''s unit unless the regulator sets tap_C;
      default 0. Export: step - neutralStep on phase C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.step
    rank: 1000
    domain_of:
    - regulator_configuration
    range: integer
    required: false

Induced

name: regulator_configuration
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file regulator_configuration.cpp

  @addtogroup regulator_configuration

  @ingroup regulator

  @{


  Inherits from: powerflow_library


  Type: Configuration (physical asset template)


  Note: Inherits from powerflow_library (not in powerflow module)'
comments:
- 'Import: no CIM template, so no class of its own; its values go on the VoltageRegulator,
  RatioTapChanger and TapChangerControl of every regulator that names it. Export:
  written from the VoltageRegulator''s tap changer and its control as <regulator>_config.'
from_schema: https://gridlabd.org/schema/glm
close_mappings:
- cim:RatioTapChanger
- cim:TapChangerControl
- cim:VoltageRegulator
is_a: glm_object
attributes:
  connect_type:
    name: connect_type
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: connect_type
    description: Designation of connection style
    comments:
    - 'Import: WYE_WYE only (every AutoTransformerEnd wye, grounded); any other raises.
      Export: always WYE_WYE.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    related_mappings:
    - cim:TransformerEnd.grounded
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    - transformer_configuration
    range: ConnectType
    required: false
  band_center:
    name: band_center
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: band_center[V]
    description: band center setting of regulator control
    comments:
    - 'Import: TapChangerControl.targetValue (V), primary volts; on LINE_DROP_COMP
      x power_transducer_ratio. Export: the target (V), over ptRatio on LINE_DROP_COMP;
      unset when the control is disabled.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:RegulatingControl.targetValue
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  band_width:
    name: band_width
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: band_width[V]
    description: band width setting of regulator control
    comments:
    - 'Import: TapChangerControl.targetDeadband (V), the full band, as band_center.
      Export: the deadband (V), likewise.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:RegulatingControl.targetDeadband
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  time_delay:
    name: time_delay
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: time_delay[s]
    description: mechanical time delay between tap changes
    comments:
    - 'Import: RatioTapChanger.initialDelay and subsequentDelay (s) = dwell_time +
      time_delay. Export: see dwell_time.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.initialDelay
    - cim:TapChanger.subsequentDelay
    owner: regulator_configuration
    domain_of:
    - capacitor
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: s
  dwell_time:
    name: dwell_time
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: dwell_time[s]
    description: time delay before a control action of regulator control
    comments:
    - 'Import: with time_delay. Export: the initialDelay (s).'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.initialDelay
    - cim:TapChanger.subsequentDelay
    owner: regulator_configuration
    domain_of:
    - capacitor
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: s
  raise_taps:
    name: raise_taps
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: raise_taps
    description: number of regulator raise taps, or the maximum raise voltage tap
      position
    comments:
    - 'Import: RatioTapChanger.highStep, also the stepVoltageIncrement divisor; 0
      raises. Export: highStep - neutralStep.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    exact_mappings:
    - cim:TapChanger.highStep
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  lower_taps:
    name: lower_taps
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: lower_taps
    description: number of regulator lower taps, or the minimum lower voltage tap
      position
    comments:
    - 'Import: RatioTapChanger.lowStep = -lower_taps; 0 raises. Export: neutralStep
      - lowStep.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.lowStep
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  current_transducer_ratio:
    name: current_transducer_ratio
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_transducer_ratio[pu]
    description: primary rating of current transformer
    comments:
    - 'Import: RatioTapChanger.ctRatio, and the line drop''s CT ratio. Export: ctRatio.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    exact_mappings:
    - cim:TapChanger.ctRatio
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: pu
  power_transducer_ratio:
    name: power_transducer_ratio
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_transducer_ratio[pu]
    description: potential transformer rating
    comments:
    - 'Import: TapChangerControl.ptRatio and RatioTapChanger.ptRatio. Export: ptRatio.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    exact_mappings:
    - cim:RegulatingControl.ptRatio
    - cim:TapChanger.ptRatio
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: pu
  compensator_r_setting_A:
    name: compensator_r_setting_A
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_r_setting_A[V]
    description: Line Drop Compensation R setting of regulator control (in volts)
      on Phase A
    comments:
    - 'Import: TapChangerControl.lineDropR (ohm) = the setting x power_transducer_ratio
      / current_transducer_ratio; needs both ratios. Export: lineDropR x ctRatio /
      ptRatio on phase A.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropR
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_r_setting_B:
    name: compensator_r_setting_B
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_r_setting_B[V]
    description: Line Drop Compensation R setting of regulator control (in volts)
      on Phase B
    comments:
    - 'Import: TapChangerControl.lineDropR (ohm) = the setting x power_transducer_ratio
      / current_transducer_ratio; needs both ratios. Export: lineDropR x ctRatio /
      ptRatio on phase B.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropR
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_r_setting_C:
    name: compensator_r_setting_C
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_r_setting_C[V]
    description: Line Drop Compensation R setting of regulator control (in volts)
      on Phase C
    comments:
    - 'Import: TapChangerControl.lineDropR (ohm) = the setting x power_transducer_ratio
      / current_transducer_ratio; needs both ratios. Export: lineDropR x ctRatio /
      ptRatio on phase C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropR
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_x_setting_A:
    name: compensator_x_setting_A
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_x_setting_A[V]
    description: Line Drop Compensation X setting of regulator control (in volts)
      on Phase A
    comments:
    - 'Import: TapChangerControl.lineDropX (ohm), as the r setting. Export: lineDropX
      x ctRatio / ptRatio on phase A.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropX
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_x_setting_B:
    name: compensator_x_setting_B
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_x_setting_B[V]
    description: Line Drop Compensation X setting of regulator control (in volts)
      on Phase B
    comments:
    - 'Import: TapChangerControl.lineDropX (ohm), as the r setting. Export: lineDropX
      x ctRatio / ptRatio on phase B.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropX
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  compensator_x_setting_C:
    name: compensator_x_setting_C
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: compensator_x_setting_C[V]
    description: Line Drop Compensation X setting of regulator control (in volts)
      on Phase C
    comments:
    - 'Import: TapChangerControl.lineDropX (ohm), as the r setting. Export: lineDropX
      x ctRatio / ptRatio on phase C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChangerControl.lineDropX
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: V
  CT_phase:
    name: CT_phase
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: CT_phase
    description: phase(s) monitored by CT
    comments:
    - 'Import: BANK: the phase whose compensator setting is read, which must be PT_phase;
      INDIVIDUAL: ignored. Export: BANK: the monitored phase, else its first.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    related_mappings:
    - cim:RegulatingControl.monitoredPhase
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: string
    required: false
  PT_phase:
    name: PT_phase
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: PT_phase
    description: phase(s) monitored by PT
    comments:
    - 'Import: BANK: TapChangerControl.monitoredPhase; INDIVIDUAL: ignored. Export:
      BANK: the monitored phase, else its first.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    related_mappings:
    - cim:RegulatingControl.monitoredPhase
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: string
    required: false
  regulation:
    name: regulation
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: regulation
    description: regulation of voltage regulator in %
    comments:
    - 'Import: stepVoltageIncrement (percent) = regulation / raise_taps; 0 raises
      unless MANUAL. Export: stepVoltageIncrement x raise_taps (per unit).'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:RatioTapChanger.stepVoltageIncrement
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: float
    required: false
    unit:
      ucum_code: pu
  control_level:
    name: control_level
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: control_level
    description: Designates whether control is on per-phase or banked level
    comments:
    - 'Import: INDIVIDUAL (default) is a unit per wired phase, BANK one gang unit.
      Export: BANK for one VoltageRegulator alone, else INDIVIDUAL.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    owner: regulator_configuration
    domain_of:
    - capacitor
    - regulator_configuration
    range: string
    required: false
  Control:
    name: Control
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Control
    description: Type of control used for regulating voltage
    comments:
    - 'Import: MANUAL (default) is enabled = controlEnabled = false; OUTPUT_VOLTAGE
      and LINE_DROP_COMP true, lineDropCompensation on LINE_DROP_COMP only; REMOTE_NODE
      on the regulator''s own output as OUTPUT_VOLTAGE. Export: MANUAL when the control
      is disabled or absent, LINE_DROP_COMP with line drop compensation, else OUTPUT_VOLTAGE.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:AutomationFunction.enabled
    - cim:TapChangerControl.lineDropCompensation
    - cim:TapChanger.controlEnabled
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: string
    required: false
  reverse_flow_control:
    name: reverse_flow_control
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reverse_flow_control
    description: Type of control used when power is flowing in reverse through the
      regulator
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: string
    required: false
  Type:
    name: Type
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Type
    description: Defines regulator type
    comments:
    - 'Import: A is typeA, B is typeB (default B). Export: B for typeB, else A.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    exact_mappings:
    - cim:VoltageRegulator.construction
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: string
    required: false
  tap_pos_A:
    name: tap_pos_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: tap_pos_A
    description: initial tap position of phase A
    comments:
    - 'Import: RatioTapChanger.step of phase A''s unit unless the regulator sets tap_A;
      default 0. Export: step - neutralStep on phase A.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.step
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  tap_pos_B:
    name: tap_pos_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: tap_pos_B
    description: initial tap position of phase B
    comments:
    - 'Import: RatioTapChanger.step of phase B''s unit unless the regulator sets tap_B;
      default 0. Export: step - neutralStep on phase B.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.step
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  tap_pos_C:
    name: tap_pos_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: tap_pos_C
    description: initial tap position of phase C
    comments:
    - 'Import: RatioTapChanger.step of phase C''s unit unless the regulator sets tap_C;
      default 0. Export: step - neutralStep on phase C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/regulator_configuration
    close_mappings:
    - cim:TapChanger.step
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - regulator_configuration
    range: integer
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: regulator_configuration
    domain_of:
    - glm_object
    range: string