Class: Line

Copyright (C) 2008 Battelle Memorial Institute

@file line.cpp

@addtogroup line

@ingroup powerflow

This file contains the definition for 4 types of lines, their

configurations and the conductors associated with these lines. The line is one

of the major parts of the method used for solving a powerflow network. In

essense the distribution network can be seen as a series of nodes and links. The

links (or lines as in this file) do most of the work, solving a series of 3

dimensional matrices, while the nodes (defined in node.cpp) are

containers and aggregators, storing the values to be used in the equation

solvers.

In general, a line contains a configuration that contains a spacing

object, and one or more conductor objects, exported as phaseA_conductor,

phaseB_conductor, phaseC_conductor, and phaseN_conductor. The line spacing

object hold information about the distances between each of the phase

conductors, while the conductor objects contain the information on the specifics

of the conductor (resistance, diameter, etc...)

Line itself is not exported, and cannot be used in a model. Instead one

of 3 types of lines are exported for use in models; underground lines, overhead

lines, and triplex (or secondary) lines. Underground lines and overhead lines

use the basic line configuration and line spacing objects, but have different

conductor classes defined for them. The overhead line conductor is the simplest

of these with just a resistance and a geometric mean radius defined. The

underground line conductor is more complex, due to the fact that each phase

conductor may have its own neutral.

Triplex lines are the third type of line exported. A special triplex

line configuration is also exported which presents 3 line conductors;

l1_conductor, l2_conductor, and lN_conductor. Also exported is a general

insulation thickness and the total diameter of the line. The conductor for

triplex lines is much the same as the overhead line conductor.

All line objects export a phase property that is a set of phases and may

be set using the bitwise or operator (A|B|C for a 3 phase line).

@{

__

Inherits from: link

__

Type: Instance (network topology element)

URI: glm:Line

 classDiagram
    class Line
    click Line href "../Line/"
      Link <|-- Line
        click Link href "../Link/"


      Line <|-- OverheadLine
        click OverheadLine href "../OverheadLine/"
      Line <|-- TriplexLine
        click TriplexLine href "../TriplexLine/"
      Line <|-- UndergroundLine
        click UndergroundLine href "../UndergroundLine/"


      Line : condition

      Line : configuration

      Line : continuous_rating_A

      Line : continuous_rating_B

      Line : continuous_rating_C

      Line : current_in_A





        Line --> "0..1" Complex : current_in_A
        click Complex href "../Complex/"



      Line : current_in_B





        Line --> "0..1" Complex : current_in_B
        click Complex href "../Complex/"



      Line : current_in_C





        Line --> "0..1" Complex : current_in_C
        click Complex href "../Complex/"



      Line : current_out_A





        Line --> "0..1" Complex : current_out_A
        click Complex href "../Complex/"



      Line : current_out_B





        Line --> "0..1" Complex : current_out_B
        click Complex href "../Complex/"



      Line : current_out_C





        Line --> "0..1" Complex : current_out_C
        click Complex href "../Complex/"



      Line : emergency_rating_A

      Line : emergency_rating_B

      Line : emergency_rating_C

      Line : fault_current_in_A





        Line --> "0..1" Complex : fault_current_in_A
        click Complex href "../Complex/"



      Line : fault_current_in_B





        Line --> "0..1" Complex : fault_current_in_B
        click Complex href "../Complex/"



      Line : fault_current_in_C





        Line --> "0..1" Complex : fault_current_in_C
        click Complex href "../Complex/"



      Line : fault_current_out_A





        Line --> "0..1" Complex : fault_current_out_A
        click Complex href "../Complex/"



      Line : fault_current_out_B





        Line --> "0..1" Complex : fault_current_out_B
        click Complex href "../Complex/"



      Line : fault_current_out_C





        Line --> "0..1" Complex : fault_current_out_C
        click Complex href "../Complex/"



      Line : fault_voltage_A





        Line --> "0..1" Complex : fault_voltage_A
        click Complex href "../Complex/"



      Line : fault_voltage_B





        Line --> "0..1" Complex : fault_voltage_B
        click Complex href "../Complex/"



      Line : fault_voltage_C





        Line --> "0..1" Complex : fault_voltage_C
        click Complex href "../Complex/"



      Line : flags

      Line : flow_direction

      Line : from_node

      Line : groupid

      Line : in_svc

      Line : inrush_convergence_value

      Line : inrush_integration_method

      Line : inrush_integration_method_capacitance





        Line --> "0..1" InrushIntegrationMethodCapacitance : inrush_integration_method_capacitance
        click InrushIntegrationMethodCapacitance href "../InrushIntegrationMethodCapacitance/"



      Line : inrush_integration_method_inductance





        Line --> "0..1" InrushIntegrationMethodInductance : inrush_integration_method_inductance
        click InrushIntegrationMethodInductance href "../InrushIntegrationMethodInductance/"



      Line : latitude

      Line : length

      Line : longitude

      Line : mean_repair_time

      Line : name

      Line : nominal_voltage

      Line : out_svc

      Line : overloaded_status

      Line : parent

      Line : pdispatch

      Line : pdispatch_offset

      Line : phases

      Line : power_in





        Line --> "0..1" Complex : power_in
        click Complex href "../Complex/"



      Line : power_in_A





        Line --> "0..1" Complex : power_in_A
        click Complex href "../Complex/"



      Line : power_in_B





        Line --> "0..1" Complex : power_in_B
        click Complex href "../Complex/"



      Line : power_in_C





        Line --> "0..1" Complex : power_in_C
        click Complex href "../Complex/"



      Line : power_losses





        Line --> "0..1" Complex : power_losses
        click Complex href "../Complex/"



      Line : power_losses_A





        Line --> "0..1" Complex : power_losses_A
        click Complex href "../Complex/"



      Line : power_losses_B





        Line --> "0..1" Complex : power_losses_B
        click Complex href "../Complex/"



      Line : power_losses_C





        Line --> "0..1" Complex : power_losses_C
        click Complex href "../Complex/"



      Line : power_out





        Line --> "0..1" Complex : power_out
        click Complex href "../Complex/"



      Line : power_out_A





        Line --> "0..1" Complex : power_out_A
        click Complex href "../Complex/"



      Line : power_out_B





        Line --> "0..1" Complex : power_out_B
        click Complex href "../Complex/"



      Line : power_out_C





        Line --> "0..1" Complex : power_out_C
        click Complex href "../Complex/"



      Line : power_out_real

      Line : rank

      Line : set_pdispatch

      Line : solution

      Line : status

      Line : to

      Line : triplex_neutral_1_value





        Line --> "0..1" Complex : triplex_neutral_1_value
        click Complex href "../Complex/"



      Line : triplex_neutral_2_value





        Line --> "0..1" Complex : triplex_neutral_2_value
        click Complex href "../Complex/"



Inheritance

Slots

Name Cardinality and Range Description Inheritance
configuration 0..1
String
direct
length 0..1
Float
direct
status 0..1
String
Link
from_node 0..1
String
from_node - source node Link
to 0..1
String
to_node - load node Link
power_in 0..1
Complex
power flow in (w Link
power_out 0..1
Complex
power flow out (w Link
power_out_real 0..1
Float
power flow out (w Link
power_losses 0..1
Complex
power losses Link
power_in_A 0..1
Complex
power flow in (w Link
power_in_B 0..1
Complex
power flow in (w Link
power_in_C 0..1
Complex
power flow in (w Link
power_out_A 0..1
Complex
power flow out (w Link
power_out_B 0..1
Complex
power flow out (w Link
power_out_C 0..1
Complex
power flow out (w Link
power_losses_A 0..1
Complex
power losses, phase A Link
power_losses_B 0..1
Complex
power losses, phase B Link
power_losses_C 0..1
Complex
power losses, phase C Link
current_out_A 0..1
Complex
current flow out of link (w Link
current_out_B 0..1
Complex
current flow out of link (w Link
current_out_C 0..1
Complex
current flow out of link (w Link
current_in_A 0..1
Complex
current flow to link (w Link
current_in_B 0..1
Complex
current flow to link (w Link
current_in_C 0..1
Complex
current flow to link (w Link
fault_current_in_A 0..1
Complex
fault current flowing in, phase A Link
fault_current_in_B 0..1
Complex
fault current flowing in, phase B Link
fault_current_in_C 0..1
Complex
fault current flowing in, phase C Link
fault_current_out_A 0..1
Complex
fault current flowing out, phase A Link
fault_current_out_B 0..1
Complex
fault current flowing out, phase B Link
fault_current_out_C 0..1
Complex
fault current flowing out, phase C Link
pdispatch 0..1
Float
Scheduled flow from->to in W Link
pdispatch_offset 0..1
Float
Offset to scheduled flow from->to in W Link
set_pdispatch 0..1
Boolean
trigger to set pdispatch equal to (power_in + power_out)/2 Link
fault_voltage_A 0..1
Complex
fault voltage, phase A Link
fault_voltage_B 0..1
Complex
fault voltage, phase B Link
fault_voltage_C 0..1
Complex
fault voltage, phase C Link
overloaded_status 0..1
Boolean
overloaded status (true/false) Link
flow_direction 0..1
String
flag used for describing direction of the flow of power Link
mean_repair_time 0..1
Float
Time after a fault clears for the object to be back in service Link
continuous_rating_A 0..1
Float
Continuous rating for phase A of this link object (set individual line segmen... Link
continuous_rating_B 0..1
Float
Continuous rating for phase B of this link object (set individual line segmen... Link
continuous_rating_C 0..1
Float
Continuous rating for phase C of this link object (set individual line segmen... Link
emergency_rating_A 0..1
Float
Emergency rating for phase A of this link object (set individual line segment... Link
emergency_rating_B 0..1
Float
Emergency rating for phase B of this link object (set individual line segment... Link
emergency_rating_C 0..1
Float
Emergency rating for phase C of this link object (set individual line segment... Link
inrush_convergence_value 0..1
Float
Tolerance, as change in line voltage drop between iterations, for deltamode i... Link
triplex_neutral_1_value 0..1
Complex
Link
triplex_neutral_2_value 0..1
Complex
Link
inrush_integration_method_capacitance 0..1
InrushIntegrationMethodCapacitance
Selected integration method to use for capacitive elements of the link Link
inrush_integration_method_inductance 0..1
InrushIntegrationMethodInductance
Selected integration method to use for inductive elements of the link Link
phases 0..1
String
PowerflowObject
nominal_voltage 0..1
Float
PowerflowObject
inrush_integration_method 0..1
String
Integration method for in-rush PowerflowObject
condition 0..1
String
PowerflowObject
solution 0..1
String
PowerflowObject
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: not written as such; overhead_line, underground_line and triplex_line each become an ACLineSegment (mRID ln_ + name). Export: an ACLineSegment is written as one of those three classes.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:Line
native glm:Line
close cim:ACLineSegment

LinkML Source

Direct

name: line
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file line.cpp

  @addtogroup line

  @ingroup powerflow

  This file contains the definition for 4 types of lines, their

  configurations and the conductors associated with these lines.  The line is one

  of the major parts of the method used for solving a powerflow network.  In

  essense the distribution network can be seen as a series of nodes and links. The

  links (or lines as in this file) do most of the work, solving a series of 3

  dimensional matrices, while the nodes (defined in node.cpp) are

  containers and aggregators, storing the values to be used in the equation

  solvers.

  In general, a line contains a configuration that contains a spacing

  object, and one or more conductor objects, exported as phaseA_conductor,

  phaseB_conductor, phaseC_conductor, and phaseN_conductor.  The line spacing

  object hold information about the distances between each of the phase

  conductors, while the conductor objects contain the information on the specifics

  of the conductor (resistance, diameter, etc...)

  Line itself is not exported, and cannot be used in a model.  Instead one

  of 3 types of lines are exported for use in models; underground lines, overhead

  lines, and triplex (or secondary) lines.  Underground lines and overhead lines

  use the basic line configuration and line spacing objects, but have different

  conductor classes defined for them.  The overhead line conductor is the simplest

  of these with just a resistance and a geometric mean radius defined.  The

  underground line conductor is more complex, due to the fact that each phase

  conductor may have its own neutral.

  Triplex lines are the third type of line exported.  A special triplex

  line configuration is also exported which presents 3 line conductors;

  l1_conductor, l2_conductor, and lN_conductor.  Also exported is a general

  insulation thickness and the total diameter of the line.  The conductor for

  triplex lines is much the same as the overhead line conductor.

  All line objects export a phase property that is a set of phases and may

  be set using the bitwise or operator (A|B|C for a 3 phase line).

  @{


  Inherits from: link


  Type: Instance (network topology element)'
comments:
- 'Import: not written as such; overhead_line, underground_line and triplex_line each
  become an ACLineSegment (mRID ln_ + name). Export: an ACLineSegment is written as
  one of those three classes.'
from_schema: https://gridlabd.org/schema/glm
close_mappings:
- cim:ACLineSegment
is_a: link
attributes:
  configuration:
    name: configuration
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: configuration
    comments:
    - 'Import: structural; ACLineSegment.WireConfiguration = wc_ + configuration (geometry,
      triplex) or lc_<configuration>_wc (matrix, the WireConfiguration that holds
      the template PerLengthPhaseImpedance). Export: the configuration written for
      the line''s geometry or matrix.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/line
    related_mappings:
    - cim:ACLineSegment.WireConfiguration
    rank: 1000
    domain_of:
    - line
    - regulator
    - transformer
    - residential_enduse
    range: string
    required: false
  length:
    name: length
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: length[ft]
    comments:
    - 'Import: copied to ACLineSegment.length in its written unit (ft); unset raises.
      Export: ACLineSegment.length (ft); unset raises.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/line
    exact_mappings:
    - cim:Conductor.length
    rank: 1000
    domain_of:
    - line
    range: float
    required: false
    unit:
      ucum_code: ft

Induced

name: line
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file line.cpp

  @addtogroup line

  @ingroup powerflow

  This file contains the definition for 4 types of lines, their

  configurations and the conductors associated with these lines.  The line is one

  of the major parts of the method used for solving a powerflow network.  In

  essense the distribution network can be seen as a series of nodes and links. The

  links (or lines as in this file) do most of the work, solving a series of 3

  dimensional matrices, while the nodes (defined in node.cpp) are

  containers and aggregators, storing the values to be used in the equation

  solvers.

  In general, a line contains a configuration that contains a spacing

  object, and one or more conductor objects, exported as phaseA_conductor,

  phaseB_conductor, phaseC_conductor, and phaseN_conductor.  The line spacing

  object hold information about the distances between each of the phase

  conductors, while the conductor objects contain the information on the specifics

  of the conductor (resistance, diameter, etc...)

  Line itself is not exported, and cannot be used in a model.  Instead one

  of 3 types of lines are exported for use in models; underground lines, overhead

  lines, and triplex (or secondary) lines.  Underground lines and overhead lines

  use the basic line configuration and line spacing objects, but have different

  conductor classes defined for them.  The overhead line conductor is the simplest

  of these with just a resistance and a geometric mean radius defined.  The

  underground line conductor is more complex, due to the fact that each phase

  conductor may have its own neutral.

  Triplex lines are the third type of line exported.  A special triplex

  line configuration is also exported which presents 3 line conductors;

  l1_conductor, l2_conductor, and lN_conductor.  Also exported is a general

  insulation thickness and the total diameter of the line.  The conductor for

  triplex lines is much the same as the overhead line conductor.

  All line objects export a phase property that is a set of phases and may

  be set using the bitwise or operator (A|B|C for a 3 phase line).

  @{


  Inherits from: link


  Type: Instance (network topology element)'
comments:
- 'Import: not written as such; overhead_line, underground_line and triplex_line each
  become an ACLineSegment (mRID ln_ + name). Export: an ACLineSegment is written as
  one of those three classes.'
from_schema: https://gridlabd.org/schema/glm
close_mappings:
- cim:ACLineSegment
is_a: link
attributes:
  configuration:
    name: configuration
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: configuration
    comments:
    - 'Import: structural; ACLineSegment.WireConfiguration = wc_ + configuration (geometry,
      triplex) or lc_<configuration>_wc (matrix, the WireConfiguration that holds
      the template PerLengthPhaseImpedance). Export: the configuration written for
      the line''s geometry or matrix.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/line
    related_mappings:
    - cim:ACLineSegment.WireConfiguration
    rank: 1000
    owner: line
    domain_of:
    - line
    - regulator
    - transformer
    - residential_enduse
    range: string
    required: false
  length:
    name: length
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: length[ft]
    comments:
    - 'Import: copied to ACLineSegment.length in its written unit (ft); unset raises.
      Export: ACLineSegment.length (ft); unset raises.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/line
    exact_mappings:
    - cim:Conductor.length
    rank: 1000
    owner: line
    domain_of:
    - line
    range: float
    required: false
    unit:
      ucum_code: ft
  status:
    name: status
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: status
    comments:
    - 'Import: a switch family device: Switch.open and Switch.normalOpen both true
      when OPEN; unset is CLOSED, noted on the row. A line or series_reactor must
      be unset or CLOSED; OPEN raises. Export: OPEN or CLOSED from the chosen switch
      state.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Switch.open
    - cim:Switch.normalOpen
    rank: 1000
    owner: line
    domain_of:
    - link
    range: string
    required: false
  from_node:
    name: from_node
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: from
    description: from_node - source node
    comments:
    - 'Import: node1, the root bus of the object named. Export: terminal 1''s bus.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Terminal.ConnectivityNode
    rank: 1000
    owner: line
    domain_of:
    - link
    range: string
    required: false
  to:
    name: to
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: to
    description: to_node - load node
    comments:
    - 'Import: node2, the root bus of the object named. Export: terminal 2''s bus.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Terminal.ConnectivityNode
    rank: 1000
    owner: line
    domain_of:
    - link
    range: string
    required: false
  power_in:
    name: power_in
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in[VA]
    description: power flow in (w.r.t from node)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out:
    name: power_out
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out[VA]
    description: power flow out (w.r.t to node)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_real:
    name: power_out_real
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_out_real[W]
    description: power flow out (w.r.t to node), real
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: W
  power_losses:
    name: power_losses
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses[VA]
    description: power losses
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_A:
    name: power_in_A
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_A[VA]
    description: power flow in (w.r.t from node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_B:
    name: power_in_B
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_B[VA]
    description: power flow in (w.r.t from node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_C:
    name: power_in_C
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_C[VA]
    description: power flow in (w.r.t from node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_A:
    name: power_out_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_A[VA]
    description: power flow out (w.r.t to node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_B:
    name: power_out_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_B[VA]
    description: power flow out (w.r.t to node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_C:
    name: power_out_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_C[VA]
    description: power flow out (w.r.t to node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_A:
    name: power_losses_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_A[VA]
    description: power losses, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_B:
    name: power_losses_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_B[VA]
    description: power losses, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_C:
    name: power_losses_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_C[VA]
    description: power losses, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  current_out_A:
    name: current_out_A
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_A[A]
    description: current flow out of link (w.r.t. to node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_out_B:
    name: current_out_B
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_B[A]
    description: current flow out of link (w.r.t. to node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_out_C:
    name: current_out_C
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_C[A]
    description: current flow out of link (w.r.t. to node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_A:
    name: current_in_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_A[A]
    description: current flow to link (w.r.t from node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_B:
    name: current_in_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_B[A]
    description: current flow to link (w.r.t from node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_C:
    name: current_in_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_C[A]
    description: current flow to link (w.r.t from node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_A:
    name: fault_current_in_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_A[A]
    description: fault current flowing in, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_B:
    name: fault_current_in_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_B[A]
    description: fault current flowing in, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_C:
    name: fault_current_in_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_C[A]
    description: fault current flowing in, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_A:
    name: fault_current_out_A
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_A[A]
    description: fault current flowing out, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_B:
    name: fault_current_out_B
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_B[A]
    description: fault current flowing out, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_C:
    name: fault_current_out_C
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_C[A]
    description: fault current flowing out, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  pdispatch:
    name: pdispatch
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pdispatch[W]
    description: Scheduled flow from->to in W
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - diesel_dg
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: W
  pdispatch_offset:
    name: pdispatch_offset
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pdispatch_offset[W]
    description: Offset to scheduled flow from->to in W
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - diesel_dg
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: W
  set_pdispatch:
    name: set_pdispatch
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: set_pdispatch
    description: trigger to set pdispatch equal to (power_in + power_out)/2
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: boolean
    required: false
  fault_voltage_A:
    name: fault_voltage_A
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_A[A]
    description: fault voltage, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_voltage_B:
    name: fault_voltage_B
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_B[A]
    description: fault voltage, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_voltage_C:
    name: fault_voltage_C
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_C[A]
    description: fault voltage, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  overloaded_status:
    name: overloaded_status
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: overloaded_status
    description: overloaded status (true/false)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: boolean
    required: false
  flow_direction:
    name: flow_direction
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flow_direction
    description: flag used for describing direction of the flow of power
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: string
    required: false
  mean_repair_time:
    name: mean_repair_time
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mean_repair_time[s]
    description: Time after a fault clears for the object to be back in service
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - node
    range: float
    required: false
    unit:
      ucum_code: s
  continuous_rating_A:
    name: continuous_rating_A
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_A[A]
    description: Continuous rating for phase A of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  continuous_rating_B:
    name: continuous_rating_B
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_B[A]
    description: Continuous rating for phase B of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  continuous_rating_C:
    name: continuous_rating_C
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_C[A]
    description: Continuous rating for phase C of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_A:
    name: emergency_rating_A
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_A[A]
    description: Emergency rating for phase A of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_B:
    name: emergency_rating_B
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_B[A]
    description: Emergency rating for phase B of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_C:
    name: emergency_rating_C
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_C[A]
    description: Emergency rating for phase C of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  inrush_convergence_value:
    name: inrush_convergence_value
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: inrush_convergence_value[V]
    description: Tolerance, as change in line voltage drop between iterations, for
      deltamode in-rush completion
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: V
  triplex_neutral_1_value:
    name: triplex_neutral_1_value
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: triplex_neutral_1_value
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
  triplex_neutral_2_value:
    name: triplex_neutral_2_value
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: triplex_neutral_2_value
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    range: Complex
    required: false
  inrush_integration_method_capacitance:
    name: inrush_integration_method_capacitance
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method_capacitance
    description: Selected integration method to use for capacitive elements of the
      link
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - load
    range: InrushIntegrationMethodCapacitance
    required: false
  inrush_integration_method_inductance:
    name: inrush_integration_method_inductance
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method_inductance
    description: Selected integration method to use for inductive elements of the
      link
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: line
    domain_of:
    - link
    - load
    range: InrushIntegrationMethodInductance
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    comments:
    - 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
      Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
      Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
      when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
      bus); a switch or reactor side 1''s A, B, C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    related_mappings:
    - cim:Terminal.phases
    rank: 1000
    owner: line
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  nominal_voltage:
    name: nominal_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_voltage[V]
    comments:
    - 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
      over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
      (V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
      LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
      / sqrt 3.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    close_mappings:
    - cim:BaseVoltage.nominalVoltage
    - cim:EnergySource.nominalVoltage
    rank: 1000
    owner: line
    domain_of:
    - powerflow_object
    - battery
    - waterheater
    range: float
    required: false
    unit:
      ucum_code: V
  inrush_integration_method:
    name: inrush_integration_method
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method
    description: Integration method for in-rush
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: line
    domain_of:
    - powerflow_object
    range: string
    required: false
  condition:
    name: condition
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: condition
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: line
    domain_of:
    - powerflow_object
    range: string
    required: false
  solution:
    name: solution
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: solution
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: line
    domain_of:
    - powerflow_object
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: line
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: line
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: line
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: line
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: line
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: line
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: line
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: line
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: line
    domain_of:
    - glm_object
    range: string