Skip to content

Class: UndergroundLine

Copyright (C) 2008 Battelle Memorial Institute

@file underground_line.cpp

@addtogroup underground_line

@ingroup line

@{

__

Inherits from: line

__

Type: Instance (network topology element)

URI: glm:UndergroundLine

 classDiagram
    class UndergroundLine
    click UndergroundLine href "../UndergroundLine/"
      Line <|-- UndergroundLine
        click Line href "../Line/"

      UndergroundLine : condition

      UndergroundLine : configuration

      UndergroundLine : continuous_rating_A

      UndergroundLine : continuous_rating_B

      UndergroundLine : continuous_rating_C

      UndergroundLine : current_in_A





        UndergroundLine --> "0..1" Complex : current_in_A
        click Complex href "../Complex/"



      UndergroundLine : current_in_B





        UndergroundLine --> "0..1" Complex : current_in_B
        click Complex href "../Complex/"



      UndergroundLine : current_in_C





        UndergroundLine --> "0..1" Complex : current_in_C
        click Complex href "../Complex/"



      UndergroundLine : current_out_A





        UndergroundLine --> "0..1" Complex : current_out_A
        click Complex href "../Complex/"



      UndergroundLine : current_out_B





        UndergroundLine --> "0..1" Complex : current_out_B
        click Complex href "../Complex/"



      UndergroundLine : current_out_C





        UndergroundLine --> "0..1" Complex : current_out_C
        click Complex href "../Complex/"



      UndergroundLine : emergency_rating_A

      UndergroundLine : emergency_rating_B

      UndergroundLine : emergency_rating_C

      UndergroundLine : fault_current_in_A





        UndergroundLine --> "0..1" Complex : fault_current_in_A
        click Complex href "../Complex/"



      UndergroundLine : fault_current_in_B





        UndergroundLine --> "0..1" Complex : fault_current_in_B
        click Complex href "../Complex/"



      UndergroundLine : fault_current_in_C





        UndergroundLine --> "0..1" Complex : fault_current_in_C
        click Complex href "../Complex/"



      UndergroundLine : fault_current_out_A





        UndergroundLine --> "0..1" Complex : fault_current_out_A
        click Complex href "../Complex/"



      UndergroundLine : fault_current_out_B





        UndergroundLine --> "0..1" Complex : fault_current_out_B
        click Complex href "../Complex/"



      UndergroundLine : fault_current_out_C





        UndergroundLine --> "0..1" Complex : fault_current_out_C
        click Complex href "../Complex/"



      UndergroundLine : fault_voltage_A





        UndergroundLine --> "0..1" Complex : fault_voltage_A
        click Complex href "../Complex/"



      UndergroundLine : fault_voltage_B





        UndergroundLine --> "0..1" Complex : fault_voltage_B
        click Complex href "../Complex/"



      UndergroundLine : fault_voltage_C





        UndergroundLine --> "0..1" Complex : fault_voltage_C
        click Complex href "../Complex/"



      UndergroundLine : flags

      UndergroundLine : flow_direction

      UndergroundLine : from_node

      UndergroundLine : groupid

      UndergroundLine : in_svc

      UndergroundLine : inrush_convergence_value

      UndergroundLine : inrush_integration_method

      UndergroundLine : inrush_integration_method_capacitance





        UndergroundLine --> "0..1" InrushIntegrationMethodCapacitance : inrush_integration_method_capacitance
        click InrushIntegrationMethodCapacitance href "../InrushIntegrationMethodCapacitance/"



      UndergroundLine : inrush_integration_method_inductance





        UndergroundLine --> "0..1" InrushIntegrationMethodInductance : inrush_integration_method_inductance
        click InrushIntegrationMethodInductance href "../InrushIntegrationMethodInductance/"



      UndergroundLine : latitude

      UndergroundLine : length

      UndergroundLine : longitude

      UndergroundLine : mean_repair_time

      UndergroundLine : name

      UndergroundLine : nominal_voltage

      UndergroundLine : out_svc

      UndergroundLine : overloaded_status

      UndergroundLine : parent

      UndergroundLine : pdispatch

      UndergroundLine : pdispatch_offset

      UndergroundLine : phases

      UndergroundLine : power_in





        UndergroundLine --> "0..1" Complex : power_in
        click Complex href "../Complex/"



      UndergroundLine : power_in_A





        UndergroundLine --> "0..1" Complex : power_in_A
        click Complex href "../Complex/"



      UndergroundLine : power_in_B





        UndergroundLine --> "0..1" Complex : power_in_B
        click Complex href "../Complex/"



      UndergroundLine : power_in_C





        UndergroundLine --> "0..1" Complex : power_in_C
        click Complex href "../Complex/"



      UndergroundLine : power_losses





        UndergroundLine --> "0..1" Complex : power_losses
        click Complex href "../Complex/"



      UndergroundLine : power_losses_A





        UndergroundLine --> "0..1" Complex : power_losses_A
        click Complex href "../Complex/"



      UndergroundLine : power_losses_B





        UndergroundLine --> "0..1" Complex : power_losses_B
        click Complex href "../Complex/"



      UndergroundLine : power_losses_C





        UndergroundLine --> "0..1" Complex : power_losses_C
        click Complex href "../Complex/"



      UndergroundLine : power_out





        UndergroundLine --> "0..1" Complex : power_out
        click Complex href "../Complex/"



      UndergroundLine : power_out_A





        UndergroundLine --> "0..1" Complex : power_out_A
        click Complex href "../Complex/"



      UndergroundLine : power_out_B





        UndergroundLine --> "0..1" Complex : power_out_B
        click Complex href "../Complex/"



      UndergroundLine : power_out_C





        UndergroundLine --> "0..1" Complex : power_out_C
        click Complex href "../Complex/"



      UndergroundLine : power_out_real

      UndergroundLine : rank

      UndergroundLine : set_pdispatch

      UndergroundLine : solution

      UndergroundLine : status

      UndergroundLine : to

      UndergroundLine : triplex_neutral_1_value





        UndergroundLine --> "0..1" Complex : triplex_neutral_1_value
        click Complex href "../Complex/"



      UndergroundLine : triplex_neutral_2_value





        UndergroundLine --> "0..1" Complex : triplex_neutral_2_value
        click Complex href "../Complex/"



Inheritance

Slots

Name Cardinality and Range Description Inheritance
configuration 0..1
String
Line
length 0..1
Float
Line
status 0..1
String
Link
from_node 0..1
String
from_node - source node Link
to 0..1
String
to_node - load node Link
power_in 0..1
Complex
power flow in (w Link
power_out 0..1
Complex
power flow out (w Link
power_out_real 0..1
Float
power flow out (w Link
power_losses 0..1
Complex
power losses Link
power_in_A 0..1
Complex
power flow in (w Link
power_in_B 0..1
Complex
power flow in (w Link
power_in_C 0..1
Complex
power flow in (w Link
power_out_A 0..1
Complex
power flow out (w Link
power_out_B 0..1
Complex
power flow out (w Link
power_out_C 0..1
Complex
power flow out (w Link
power_losses_A 0..1
Complex
power losses, phase A Link
power_losses_B 0..1
Complex
power losses, phase B Link
power_losses_C 0..1
Complex
power losses, phase C Link
current_out_A 0..1
Complex
current flow out of link (w Link
current_out_B 0..1
Complex
current flow out of link (w Link
current_out_C 0..1
Complex
current flow out of link (w Link
current_in_A 0..1
Complex
current flow to link (w Link
current_in_B 0..1
Complex
current flow to link (w Link
current_in_C 0..1
Complex
current flow to link (w Link
fault_current_in_A 0..1
Complex
fault current flowing in, phase A Link
fault_current_in_B 0..1
Complex
fault current flowing in, phase B Link
fault_current_in_C 0..1
Complex
fault current flowing in, phase C Link
fault_current_out_A 0..1
Complex
fault current flowing out, phase A Link
fault_current_out_B 0..1
Complex
fault current flowing out, phase B Link
fault_current_out_C 0..1
Complex
fault current flowing out, phase C Link
pdispatch 0..1
Float
Scheduled flow from->to in W Link
pdispatch_offset 0..1
Float
Offset to scheduled flow from->to in W Link
set_pdispatch 0..1
Boolean
trigger to set pdispatch equal to (power_in + power_out)/2 Link
fault_voltage_A 0..1
Complex
fault voltage, phase A Link
fault_voltage_B 0..1
Complex
fault voltage, phase B Link
fault_voltage_C 0..1
Complex
fault voltage, phase C Link
overloaded_status 0..1
Boolean
overloaded status (true/false) Link
flow_direction 0..1
String
flag used for describing direction of the flow of power Link
mean_repair_time 0..1
Float
Time after a fault clears for the object to be back in service Link
continuous_rating_A 0..1
Float
Continuous rating for phase A of this link object (set individual line segmen... Link
continuous_rating_B 0..1
Float
Continuous rating for phase B of this link object (set individual line segmen... Link
continuous_rating_C 0..1
Float
Continuous rating for phase C of this link object (set individual line segmen... Link
emergency_rating_A 0..1
Float
Emergency rating for phase A of this link object (set individual line segment... Link
emergency_rating_B 0..1
Float
Emergency rating for phase B of this link object (set individual line segment... Link
emergency_rating_C 0..1
Float
Emergency rating for phase C of this link object (set individual line segment... Link
inrush_convergence_value 0..1
Float
Tolerance, as change in line voltage drop between iterations, for deltamode i... Link
triplex_neutral_1_value 0..1
Complex
Link
triplex_neutral_2_value 0..1
Complex
Link
inrush_integration_method_capacitance 0..1
InrushIntegrationMethodCapacitance
Selected integration method to use for capacitive elements of the link Link
inrush_integration_method_inductance 0..1
InrushIntegrationMethodInductance
Selected integration method to use for inductive elements of the link Link
phases 0..1
String
PowerflowObject
nominal_voltage 0..1
Float
PowerflowObject
inrush_integration_method 0..1
String
Integration method for in-rush PowerflowObject
condition 0..1
String
PowerflowObject
solution 0..1
String
PowerflowObject
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: ACLineSegment, mRID ln_ + name (underground_line.cimtbl). Export: an ACLineSegment whose geometry has a cable (CableInfo) wire is written as it.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:UndergroundLine
native glm:UndergroundLine
close cim:ACLineSegment

LinkML Source

Direct

name: underground_line
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file underground_line.cpp

  @addtogroup underground_line

  @ingroup line

  @{


  Inherits from: line


  Type: Instance (network topology element)'
comments:
- 'Import: ACLineSegment, mRID ln_ + name (underground_line.cimtbl). Export: an ACLineSegment
  whose geometry has a cable (CableInfo) wire is written as it.'
from_schema: https://gridlabd.org/schema/glm
close_mappings:
- cim:ACLineSegment
is_a: line

Induced

name: underground_line
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file underground_line.cpp

  @addtogroup underground_line

  @ingroup line

  @{


  Inherits from: line


  Type: Instance (network topology element)'
comments:
- 'Import: ACLineSegment, mRID ln_ + name (underground_line.cimtbl). Export: an ACLineSegment
  whose geometry has a cable (CableInfo) wire is written as it.'
from_schema: https://gridlabd.org/schema/glm
close_mappings:
- cim:ACLineSegment
is_a: line
attributes:
  configuration:
    name: configuration
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: configuration
    comments:
    - 'Import: structural; ACLineSegment.WireConfiguration = wc_ + configuration (geometry,
      triplex) or lc_<configuration>_wc (matrix, the WireConfiguration that holds
      the template PerLengthPhaseImpedance). Export: the configuration written for
      the line''s geometry or matrix.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/line
    related_mappings:
    - cim:ACLineSegment.WireConfiguration
    rank: 1000
    owner: underground_line
    domain_of:
    - line
    - regulator
    - transformer
    - residential_enduse
    range: string
    required: false
  length:
    name: length
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: length[ft]
    comments:
    - 'Import: copied to ACLineSegment.length in its written unit (ft); unset raises.
      Export: ACLineSegment.length (ft); unset raises.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/line
    exact_mappings:
    - cim:Conductor.length
    rank: 1000
    owner: underground_line
    domain_of:
    - line
    range: float
    required: false
    unit:
      ucum_code: ft
  status:
    name: status
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: status
    comments:
    - 'Import: a switch family device: Switch.open and Switch.normalOpen both true
      when OPEN; unset is CLOSED, noted on the row. A line or series_reactor must
      be unset or CLOSED; OPEN raises. Export: OPEN or CLOSED from the chosen switch
      state.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Switch.open
    - cim:Switch.normalOpen
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: string
    required: false
  from_node:
    name: from_node
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: from
    description: from_node - source node
    comments:
    - 'Import: node1, the root bus of the object named. Export: terminal 1''s bus.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Terminal.ConnectivityNode
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: string
    required: false
  to:
    name: to
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: to
    description: to_node - load node
    comments:
    - 'Import: node2, the root bus of the object named. Export: terminal 2''s bus.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Terminal.ConnectivityNode
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: string
    required: false
  power_in:
    name: power_in
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in[VA]
    description: power flow in (w.r.t from node)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out:
    name: power_out
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out[VA]
    description: power flow out (w.r.t to node)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_real:
    name: power_out_real
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_out_real[W]
    description: power flow out (w.r.t to node), real
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: W
  power_losses:
    name: power_losses
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses[VA]
    description: power losses
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_A:
    name: power_in_A
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_A[VA]
    description: power flow in (w.r.t from node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_B:
    name: power_in_B
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_B[VA]
    description: power flow in (w.r.t from node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_C:
    name: power_in_C
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_C[VA]
    description: power flow in (w.r.t from node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_A:
    name: power_out_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_A[VA]
    description: power flow out (w.r.t to node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_B:
    name: power_out_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_B[VA]
    description: power flow out (w.r.t to node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_C:
    name: power_out_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_C[VA]
    description: power flow out (w.r.t to node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_A:
    name: power_losses_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_A[VA]
    description: power losses, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_B:
    name: power_losses_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_B[VA]
    description: power losses, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_C:
    name: power_losses_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_C[VA]
    description: power losses, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  current_out_A:
    name: current_out_A
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_A[A]
    description: current flow out of link (w.r.t. to node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_out_B:
    name: current_out_B
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_B[A]
    description: current flow out of link (w.r.t. to node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_out_C:
    name: current_out_C
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_C[A]
    description: current flow out of link (w.r.t. to node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_A:
    name: current_in_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_A[A]
    description: current flow to link (w.r.t from node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_B:
    name: current_in_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_B[A]
    description: current flow to link (w.r.t from node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_C:
    name: current_in_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_C[A]
    description: current flow to link (w.r.t from node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_A:
    name: fault_current_in_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_A[A]
    description: fault current flowing in, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_B:
    name: fault_current_in_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_B[A]
    description: fault current flowing in, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_C:
    name: fault_current_in_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_C[A]
    description: fault current flowing in, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_A:
    name: fault_current_out_A
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_A[A]
    description: fault current flowing out, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_B:
    name: fault_current_out_B
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_B[A]
    description: fault current flowing out, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_C:
    name: fault_current_out_C
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_C[A]
    description: fault current flowing out, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  pdispatch:
    name: pdispatch
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pdispatch[W]
    description: Scheduled flow from->to in W
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - diesel_dg
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: W
  pdispatch_offset:
    name: pdispatch_offset
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pdispatch_offset[W]
    description: Offset to scheduled flow from->to in W
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - diesel_dg
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: W
  set_pdispatch:
    name: set_pdispatch
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: set_pdispatch
    description: trigger to set pdispatch equal to (power_in + power_out)/2
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: boolean
    required: false
  fault_voltage_A:
    name: fault_voltage_A
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_A[A]
    description: fault voltage, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_voltage_B:
    name: fault_voltage_B
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_B[A]
    description: fault voltage, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_voltage_C:
    name: fault_voltage_C
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_C[A]
    description: fault voltage, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  overloaded_status:
    name: overloaded_status
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: overloaded_status
    description: overloaded status (true/false)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: boolean
    required: false
  flow_direction:
    name: flow_direction
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flow_direction
    description: flag used for describing direction of the flow of power
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: string
    required: false
  mean_repair_time:
    name: mean_repair_time
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mean_repair_time[s]
    description: Time after a fault clears for the object to be back in service
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - node
    range: float
    required: false
    unit:
      ucum_code: s
  continuous_rating_A:
    name: continuous_rating_A
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_A[A]
    description: Continuous rating for phase A of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  continuous_rating_B:
    name: continuous_rating_B
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_B[A]
    description: Continuous rating for phase B of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  continuous_rating_C:
    name: continuous_rating_C
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_C[A]
    description: Continuous rating for phase C of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_A:
    name: emergency_rating_A
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_A[A]
    description: Emergency rating for phase A of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_B:
    name: emergency_rating_B
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_B[A]
    description: Emergency rating for phase B of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_C:
    name: emergency_rating_C
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_C[A]
    description: Emergency rating for phase C of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  inrush_convergence_value:
    name: inrush_convergence_value
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: inrush_convergence_value[V]
    description: Tolerance, as change in line voltage drop between iterations, for
      deltamode in-rush completion
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: V
  triplex_neutral_1_value:
    name: triplex_neutral_1_value
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: triplex_neutral_1_value
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
  triplex_neutral_2_value:
    name: triplex_neutral_2_value
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: triplex_neutral_2_value
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    range: Complex
    required: false
  inrush_integration_method_capacitance:
    name: inrush_integration_method_capacitance
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method_capacitance
    description: Selected integration method to use for capacitive elements of the
      link
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - load
    range: InrushIntegrationMethodCapacitance
    required: false
  inrush_integration_method_inductance:
    name: inrush_integration_method_inductance
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method_inductance
    description: Selected integration method to use for inductive elements of the
      link
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: underground_line
    domain_of:
    - link
    - load
    range: InrushIntegrationMethodInductance
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    comments:
    - 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
      Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
      Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
      when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
      bus); a switch or reactor side 1''s A, B, C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    related_mappings:
    - cim:Terminal.phases
    rank: 1000
    owner: underground_line
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  nominal_voltage:
    name: nominal_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_voltage[V]
    comments:
    - 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
      over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
      (V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
      LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
      / sqrt 3.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    close_mappings:
    - cim:BaseVoltage.nominalVoltage
    - cim:EnergySource.nominalVoltage
    rank: 1000
    owner: underground_line
    domain_of:
    - powerflow_object
    - battery
    - waterheater
    range: float
    required: false
    unit:
      ucum_code: V
  inrush_integration_method:
    name: inrush_integration_method
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method
    description: Integration method for in-rush
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: underground_line
    domain_of:
    - powerflow_object
    range: string
    required: false
  condition:
    name: condition
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: condition
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: underground_line
    domain_of:
    - powerflow_object
    range: string
    required: false
  solution:
    name: solution
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: solution
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: underground_line
    domain_of:
    - powerflow_object
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: underground_line
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: underground_line
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: underground_line
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: underground_line
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: underground_line
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: underground_line
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: underground_line
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: underground_line
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: underground_line
    domain_of:
    - glm_object
    range: string