Skip to content

Slot: continuous_rating_C

Continuous rating for phase C of this link object (set individual line segments)

URI: glm:continuous_rating_C

Applicable Classes

Name Description Modifies Slot
Fuse Copyright (C) 2008 Battelle Memorial Institute no
Line Copyright (C) 2008 Battelle Memorial Institute no
Link Copyright (C) 2008 Battelle Memorial Institute no
OverheadLine Copyright (C) 2008 Battelle Memorial Institute no
Recloser Copyright (C) 2011 Battelle Memorial Institute no
Regulator Copyright (C) 2008 Battelle Memorial Institute no
Sectionalizer Copyright (C) 2011 Battelle Memorial Institute no
SeriesCompensator **************** Code injection point ***************** no
SeriesReactor Copyright (C) 2009 Battelle Memorial Institute no
Switch Copyright (C) 2008 Battelle Memorial Institute no
Transformer Copyright (C) 2008 Battelle Memorial Institute no
TriplexLine Copyright (C) 2008 Battelle Memorial Institute no
UndergroundLine Copyright (C) 2008 Battelle Memorial Institute no
Vfd Copyright (C) 2017 Battelle Memorial Institute no

Properties

Type and Range

Property Value
Range Float
Domain Of Link
### Slot Characteristics
Property Value
Owner Link
Additional Constraints **Unit:** | Property | Value | | --- | --- | | ucum_code | A |

Comments

  • Import: CurrentLimit.normalValue (A) of the normal limit on the equipment's own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits normal, written on each phase of the equipment.

Identifier and Mapping Information

Annotations

property value
order 40
value_type float
precision 6
native_name continuous_rating_C[A]

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:continuous_rating_C
native glm:continuous_rating_C
close cim:CurrentLimit.normalValue

LinkML Source

name: continuous_rating_C
annotations:
  order:
    tag: order
    value: 40
  value_type:
    tag: value_type
    value: float
  precision:
    tag: precision
    value: 6
  native_name:
    tag: native_name
    value: continuous_rating_C[A]
description: Continuous rating for phase C of this link object (set individual line
  segments)
comments:
- 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s own
  OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
  normal, written on each phase of the equipment.'
from_schema: https://gridlabd.org/schema/glm
close_mappings:
- cim:CurrentLimit.normalValue
rank: 1000
owner: link
domain_of:
- link
range: float
required: false
unit:
  ucum_code: A