Class: Regulator¶
Copyright (C) 2008 Battelle Memorial Institute
@file regulator.cpp
@addtogroup powerflow_regulator Regulator
@ingroup powerflow
@{
__
Inherits from: link
__
Type: Instance (network topology element)
URI: glm:Regulator
classDiagram
class Regulator
click Regulator href "../Regulator/"
Link <|-- Regulator
click Link href "../Link/"
Regulator : condition
Regulator : configuration
Regulator : continuous_rating_A
Regulator : continuous_rating_B
Regulator : continuous_rating_C
Regulator : current_in_A
Regulator --> "0..1" Complex : current_in_A
click Complex href "../Complex/"
Regulator : current_in_B
Regulator --> "0..1" Complex : current_in_B
click Complex href "../Complex/"
Regulator : current_in_C
Regulator --> "0..1" Complex : current_in_C
click Complex href "../Complex/"
Regulator : current_out_A
Regulator --> "0..1" Complex : current_out_A
click Complex href "../Complex/"
Regulator : current_out_B
Regulator --> "0..1" Complex : current_out_B
click Complex href "../Complex/"
Regulator : current_out_C
Regulator --> "0..1" Complex : current_out_C
click Complex href "../Complex/"
Regulator : emergency_rating_A
Regulator : emergency_rating_B
Regulator : emergency_rating_C
Regulator : fault_current_in_A
Regulator --> "0..1" Complex : fault_current_in_A
click Complex href "../Complex/"
Regulator : fault_current_in_B
Regulator --> "0..1" Complex : fault_current_in_B
click Complex href "../Complex/"
Regulator : fault_current_in_C
Regulator --> "0..1" Complex : fault_current_in_C
click Complex href "../Complex/"
Regulator : fault_current_out_A
Regulator --> "0..1" Complex : fault_current_out_A
click Complex href "../Complex/"
Regulator : fault_current_out_B
Regulator --> "0..1" Complex : fault_current_out_B
click Complex href "../Complex/"
Regulator : fault_current_out_C
Regulator --> "0..1" Complex : fault_current_out_C
click Complex href "../Complex/"
Regulator : fault_voltage_A
Regulator --> "0..1" Complex : fault_voltage_A
click Complex href "../Complex/"
Regulator : fault_voltage_B
Regulator --> "0..1" Complex : fault_voltage_B
click Complex href "../Complex/"
Regulator : fault_voltage_C
Regulator --> "0..1" Complex : fault_voltage_C
click Complex href "../Complex/"
Regulator : flags
Regulator : flow_direction
Regulator : from_node
Regulator : groupid
Regulator : in_svc
Regulator : inrush_convergence_value
Regulator : inrush_integration_method
Regulator : inrush_integration_method_capacitance
Regulator --> "0..1" InrushIntegrationMethodCapacitance : inrush_integration_method_capacitance
click InrushIntegrationMethodCapacitance href "../InrushIntegrationMethodCapacitance/"
Regulator : inrush_integration_method_inductance
Regulator --> "0..1" InrushIntegrationMethodInductance : inrush_integration_method_inductance
click InrushIntegrationMethodInductance href "../InrushIntegrationMethodInductance/"
Regulator : latitude
Regulator : longitude
Regulator : mean_repair_time
Regulator : msg_mode
Regulator : name
Regulator : nominal_voltage
Regulator : out_svc
Regulator : overloaded_status
Regulator : parent
Regulator : pdispatch
Regulator : pdispatch_offset
Regulator : phases
Regulator : power_in
Regulator --> "0..1" Complex : power_in
click Complex href "../Complex/"
Regulator : power_in_A
Regulator --> "0..1" Complex : power_in_A
click Complex href "../Complex/"
Regulator : power_in_B
Regulator --> "0..1" Complex : power_in_B
click Complex href "../Complex/"
Regulator : power_in_C
Regulator --> "0..1" Complex : power_in_C
click Complex href "../Complex/"
Regulator : power_losses
Regulator --> "0..1" Complex : power_losses
click Complex href "../Complex/"
Regulator : power_losses_A
Regulator --> "0..1" Complex : power_losses_A
click Complex href "../Complex/"
Regulator : power_losses_B
Regulator --> "0..1" Complex : power_losses_B
click Complex href "../Complex/"
Regulator : power_losses_C
Regulator --> "0..1" Complex : power_losses_C
click Complex href "../Complex/"
Regulator : power_out
Regulator --> "0..1" Complex : power_out
click Complex href "../Complex/"
Regulator : power_out_A
Regulator --> "0..1" Complex : power_out_A
click Complex href "../Complex/"
Regulator : power_out_B
Regulator --> "0..1" Complex : power_out_B
click Complex href "../Complex/"
Regulator : power_out_C
Regulator --> "0..1" Complex : power_out_C
click Complex href "../Complex/"
Regulator : power_out_real
Regulator : rank
Regulator : regulator_resistance
Regulator : remote_voltage_A
Regulator --> "0..1" Complex : remote_voltage_A
click Complex href "../Complex/"
Regulator : remote_voltage_B
Regulator --> "0..1" Complex : remote_voltage_B
click Complex href "../Complex/"
Regulator : remote_voltage_C
Regulator --> "0..1" Complex : remote_voltage_C
click Complex href "../Complex/"
Regulator : sense_node
Regulator : set_pdispatch
Regulator : solution
Regulator : status
Regulator : tap_A
Regulator : tap_A_change_count
Regulator : tap_B
Regulator : tap_B_change_count
Regulator : tap_C
Regulator : tap_C_change_count
Regulator : to
Regulator : triplex_neutral_1_value
Regulator --> "0..1" Complex : triplex_neutral_1_value
click Complex href "../Complex/"
Regulator : triplex_neutral_2_value
Regulator --> "0..1" Complex : triplex_neutral_2_value
click Complex href "../Complex/"
Inheritance¶
- GlmObject
- PowerflowObject
- Link
- Regulator
- Link
- PowerflowObject
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| configuration | 0..1 String |
reference to the regulator_configuration object used to determine regulator p... | direct |
| tap_A | 0..1 Integer |
current tap position of tap A | direct |
| tap_B | 0..1 Integer |
current tap position of tap B | direct |
| tap_C | 0..1 Integer |
current tap position of tap C | direct |
| msg_mode | 0..1 String |
messages regarding remote node voltage to come internally from gridlabd or ex... | direct |
| remote_voltage_A | 0..1 Complex |
remote node voltage, Phase A to ground | direct |
| remote_voltage_B | 0..1 Complex |
remote node voltage, Phase B to ground | direct |
| remote_voltage_C | 0..1 Complex |
remote node voltage, Phase C to ground | direct |
| tap_A_change_count | 0..1 Float |
count of all physical tap changes on phase A since beginning of simulation (p... | direct |
| tap_B_change_count | 0..1 Float |
count of all physical tap changes on phase B since beginning of simulation (p... | direct |
| tap_C_change_count | 0..1 Float |
count of all physical tap changes on phase C since beginning of simulation (p... | direct |
| sense_node | 0..1 String |
Node to be monitored for voltage control in remote sense mode | direct |
| regulator_resistance | 0..1 Float |
The resistance value of the regulator when it is not blown | direct |
| status | 0..1 String |
Link | |
| from_node | 0..1 String |
from_node - source node | Link |
| to | 0..1 String |
to_node - load node | Link |
| power_in | 0..1 Complex |
power flow in (w | Link |
| power_out | 0..1 Complex |
power flow out (w | Link |
| power_out_real | 0..1 Float |
power flow out (w | Link |
| power_losses | 0..1 Complex |
power losses | Link |
| power_in_A | 0..1 Complex |
power flow in (w | Link |
| power_in_B | 0..1 Complex |
power flow in (w | Link |
| power_in_C | 0..1 Complex |
power flow in (w | Link |
| power_out_A | 0..1 Complex |
power flow out (w | Link |
| power_out_B | 0..1 Complex |
power flow out (w | Link |
| power_out_C | 0..1 Complex |
power flow out (w | Link |
| power_losses_A | 0..1 Complex |
power losses, phase A | Link |
| power_losses_B | 0..1 Complex |
power losses, phase B | Link |
| power_losses_C | 0..1 Complex |
power losses, phase C | Link |
| current_out_A | 0..1 Complex |
current flow out of link (w | Link |
| current_out_B | 0..1 Complex |
current flow out of link (w | Link |
| current_out_C | 0..1 Complex |
current flow out of link (w | Link |
| current_in_A | 0..1 Complex |
current flow to link (w | Link |
| current_in_B | 0..1 Complex |
current flow to link (w | Link |
| current_in_C | 0..1 Complex |
current flow to link (w | Link |
| fault_current_in_A | 0..1 Complex |
fault current flowing in, phase A | Link |
| fault_current_in_B | 0..1 Complex |
fault current flowing in, phase B | Link |
| fault_current_in_C | 0..1 Complex |
fault current flowing in, phase C | Link |
| fault_current_out_A | 0..1 Complex |
fault current flowing out, phase A | Link |
| fault_current_out_B | 0..1 Complex |
fault current flowing out, phase B | Link |
| fault_current_out_C | 0..1 Complex |
fault current flowing out, phase C | Link |
| pdispatch | 0..1 Float |
Scheduled flow from->to in W | Link |
| pdispatch_offset | 0..1 Float |
Offset to scheduled flow from->to in W | Link |
| set_pdispatch | 0..1 Boolean |
trigger to set pdispatch equal to (power_in + power_out)/2 | Link |
| fault_voltage_A | 0..1 Complex |
fault voltage, phase A | Link |
| fault_voltage_B | 0..1 Complex |
fault voltage, phase B | Link |
| fault_voltage_C | 0..1 Complex |
fault voltage, phase C | Link |
| overloaded_status | 0..1 Boolean |
overloaded status (true/false) | Link |
| flow_direction | 0..1 String |
flag used for describing direction of the flow of power | Link |
| mean_repair_time | 0..1 Float |
Time after a fault clears for the object to be back in service | Link |
| continuous_rating_A | 0..1 Float |
Continuous rating for phase A of this link object (set individual line segmen... | Link |
| continuous_rating_B | 0..1 Float |
Continuous rating for phase B of this link object (set individual line segmen... | Link |
| continuous_rating_C | 0..1 Float |
Continuous rating for phase C of this link object (set individual line segmen... | Link |
| emergency_rating_A | 0..1 Float |
Emergency rating for phase A of this link object (set individual line segment... | Link |
| emergency_rating_B | 0..1 Float |
Emergency rating for phase B of this link object (set individual line segment... | Link |
| emergency_rating_C | 0..1 Float |
Emergency rating for phase C of this link object (set individual line segment... | Link |
| inrush_convergence_value | 0..1 Float |
Tolerance, as change in line voltage drop between iterations, for deltamode i... | Link |
| triplex_neutral_1_value | 0..1 Complex |
Link | |
| triplex_neutral_2_value | 0..1 Complex |
Link | |
| inrush_integration_method_capacitance | 0..1 InrushIntegrationMethodCapacitance |
Selected integration method to use for capacitive elements of the link | Link |
| inrush_integration_method_inductance | 0..1 InrushIntegrationMethodInductance |
Selected integration method to use for inductive elements of the link | Link |
| phases | 0..1 String |
PowerflowObject | |
| nominal_voltage | 0..1 Float |
PowerflowObject | |
| inrush_integration_method | 0..1 String |
Integration method for in-rush | PowerflowObject |
| condition | 0..1 String |
PowerflowObject | |
| solution | 0..1 String |
PowerflowObject | |
| name | 1 String |
The object's name; unique across the model | GlmObject |
| parent | 0..1 String |
The parent object's name | GlmObject |
| groupid | 0..1 String |
Free-text group label | GlmObject |
| latitude | 0..1 String |
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) | GlmObject |
| longitude | 0..1 String |
Longitude, as written | GlmObject |
| in_svc | 0..1 String |
Timestamp the object enters service | GlmObject |
| out_svc | 0..1 String |
Timestamp the object leaves service | GlmObject |
| rank | 0..1 String |
Solver rank | GlmObject |
| flags | 0..1 String |
Core object flags | GlmObject |
Comments¶
- Import: VoltageRegulator, mRID xf_ + name (INDIVIDUAL: name +
) (regulator.cimtbl), with two AutoTransformerEnds, a TapChangerControl (rc ) and a RatioTapChanger per unit; a regulator_configuration's values go on every unit. Export: VoltageRegulator is written as it.
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridlabd.org/schema/glm
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | glm:Regulator |
| native | glm:Regulator |
| exact | cim:VoltageRegulator |
| close | cim:RatioTapChanger, cim:TapChangerControl |
LinkML Source¶
Direct¶
name: regulator
description: 'Copyright (C) 2008 Battelle Memorial Institute
@file regulator.cpp
@addtogroup powerflow_regulator Regulator
@ingroup powerflow
@{
Inherits from: link
Type: Instance (network topology element)'
comments:
- 'Import: VoltageRegulator, mRID xf_ + name (INDIVIDUAL: name + _<phase>) (regulator.cimtbl),
with two AutoTransformerEnds, a TapChangerControl (rc_) and a RatioTapChanger per
unit; a regulator_configuration''s values go on every unit. Export: VoltageRegulator
is written as it.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:VoltageRegulator
close_mappings:
- cim:RatioTapChanger
- cim:TapChangerControl
is_a: link
attributes:
configuration:
name: configuration
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: configuration
description: reference to the regulator_configuration object used to determine
regulator properties
comments:
- 'Import: a regulator_configuration; its values land on every unit, CIM has no
regulator template. Export: written as its own <regulator>_config.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
domain_of:
- line
- regulator
- transformer
- residential_enduse
range: string
required: false
tap_A:
name: tap_A
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: tap_A
description: current tap position of tap A
comments:
- 'Import: RatioTapChanger.step of phase A''s unit, over tap_pos_A. Export: tap_pos_A
of the configuration, step - neutralStep.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
close_mappings:
- cim:TapChanger.step
rank: 1000
domain_of:
- regulator
range: integer
required: false
tap_B:
name: tap_B
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: tap_B
description: current tap position of tap B
comments:
- 'Import: RatioTapChanger.step of phase B''s unit, over tap_pos_B. Export: tap_pos_B
of the configuration, step - neutralStep.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
close_mappings:
- cim:TapChanger.step
rank: 1000
domain_of:
- regulator
range: integer
required: false
tap_C:
name: tap_C
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: tap_C
description: current tap position of tap C
comments:
- 'Import: RatioTapChanger.step of phase C''s unit, over tap_pos_C. Export: tap_pos_C
of the configuration, step - neutralStep.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
close_mappings:
- cim:TapChanger.step
rank: 1000
domain_of:
- regulator
range: integer
required: false
msg_mode:
name: msg_mode
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: msg_mode
description: messages regarding remote node voltage to come internally from gridlabd
or externally through co-simulation. Set to EXTERNAL only if you have co-simulation
enabled
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
domain_of:
- regulator
range: string
required: false
remote_voltage_A:
name: remote_voltage_A
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: remote_voltage_A[V]
description: remote node voltage, Phase A to ground
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
domain_of:
- regulator
range: Complex
required: false
unit:
ucum_code: V
remote_voltage_B:
name: remote_voltage_B
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: remote_voltage_B[V]
description: remote node voltage, Phase B to ground
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
domain_of:
- regulator
range: Complex
required: false
unit:
ucum_code: V
remote_voltage_C:
name: remote_voltage_C
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: remote_voltage_C[V]
description: remote node voltage, Phase C to ground
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
domain_of:
- regulator
range: Complex
required: false
unit:
ucum_code: V
tap_A_change_count:
name: tap_A_change_count
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: tap_A_change_count
description: count of all physical tap changes on phase A since beginning of simulation
(plus initial value)
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
domain_of:
- regulator
range: float
required: false
tap_B_change_count:
name: tap_B_change_count
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: tap_B_change_count
description: count of all physical tap changes on phase B since beginning of simulation
(plus initial value)
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
domain_of:
- regulator
range: float
required: false
tap_C_change_count:
name: tap_C_change_count
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: tap_C_change_count
description: count of all physical tap changes on phase C since beginning of simulation
(plus initial value)
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
domain_of:
- regulator
range: float
required: false
sense_node:
name: sense_node
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: sense_node
description: Node to be monitored for voltage control in remote sense mode
comments:
- 'Import: REMOTE_NODE must name the regulator''s own to bus, as OUTPUT_VOLTAGE
(the control''s Terminal is end 2); elsewhere raises. Export: not written.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
related_mappings:
- cim:RegulatingControl.Terminal
rank: 1000
domain_of:
- regulator
range: string
required: false
regulator_resistance:
name: regulator_resistance
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: regulator_resistance[Ohm]
description: The resistance value of the regulator when it is not blown.
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
domain_of:
- regulator
range: float
required: false
unit:
ucum_code: Ohm
Induced¶
name: regulator
description: 'Copyright (C) 2008 Battelle Memorial Institute
@file regulator.cpp
@addtogroup powerflow_regulator Regulator
@ingroup powerflow
@{
Inherits from: link
Type: Instance (network topology element)'
comments:
- 'Import: VoltageRegulator, mRID xf_ + name (INDIVIDUAL: name + _<phase>) (regulator.cimtbl),
with two AutoTransformerEnds, a TapChangerControl (rc_) and a RatioTapChanger per
unit; a regulator_configuration''s values go on every unit. Export: VoltageRegulator
is written as it.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:VoltageRegulator
close_mappings:
- cim:RatioTapChanger
- cim:TapChangerControl
is_a: link
attributes:
configuration:
name: configuration
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: configuration
description: reference to the regulator_configuration object used to determine
regulator properties
comments:
- 'Import: a regulator_configuration; its values land on every unit, CIM has no
regulator template. Export: written as its own <regulator>_config.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
owner: regulator
domain_of:
- line
- regulator
- transformer
- residential_enduse
range: string
required: false
tap_A:
name: tap_A
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: tap_A
description: current tap position of tap A
comments:
- 'Import: RatioTapChanger.step of phase A''s unit, over tap_pos_A. Export: tap_pos_A
of the configuration, step - neutralStep.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
close_mappings:
- cim:TapChanger.step
rank: 1000
owner: regulator
domain_of:
- regulator
range: integer
required: false
tap_B:
name: tap_B
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: tap_B
description: current tap position of tap B
comments:
- 'Import: RatioTapChanger.step of phase B''s unit, over tap_pos_B. Export: tap_pos_B
of the configuration, step - neutralStep.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
close_mappings:
- cim:TapChanger.step
rank: 1000
owner: regulator
domain_of:
- regulator
range: integer
required: false
tap_C:
name: tap_C
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: tap_C
description: current tap position of tap C
comments:
- 'Import: RatioTapChanger.step of phase C''s unit, over tap_pos_C. Export: tap_pos_C
of the configuration, step - neutralStep.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
close_mappings:
- cim:TapChanger.step
rank: 1000
owner: regulator
domain_of:
- regulator
range: integer
required: false
msg_mode:
name: msg_mode
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: msg_mode
description: messages regarding remote node voltage to come internally from gridlabd
or externally through co-simulation. Set to EXTERNAL only if you have co-simulation
enabled
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
owner: regulator
domain_of:
- regulator
range: string
required: false
remote_voltage_A:
name: remote_voltage_A
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: remote_voltage_A[V]
description: remote node voltage, Phase A to ground
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
owner: regulator
domain_of:
- regulator
range: Complex
required: false
unit:
ucum_code: V
remote_voltage_B:
name: remote_voltage_B
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: remote_voltage_B[V]
description: remote node voltage, Phase B to ground
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
owner: regulator
domain_of:
- regulator
range: Complex
required: false
unit:
ucum_code: V
remote_voltage_C:
name: remote_voltage_C
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: remote_voltage_C[V]
description: remote node voltage, Phase C to ground
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
owner: regulator
domain_of:
- regulator
range: Complex
required: false
unit:
ucum_code: V
tap_A_change_count:
name: tap_A_change_count
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: tap_A_change_count
description: count of all physical tap changes on phase A since beginning of simulation
(plus initial value)
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
owner: regulator
domain_of:
- regulator
range: float
required: false
tap_B_change_count:
name: tap_B_change_count
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: tap_B_change_count
description: count of all physical tap changes on phase B since beginning of simulation
(plus initial value)
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
owner: regulator
domain_of:
- regulator
range: float
required: false
tap_C_change_count:
name: tap_C_change_count
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: tap_C_change_count
description: count of all physical tap changes on phase C since beginning of simulation
(plus initial value)
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
owner: regulator
domain_of:
- regulator
range: float
required: false
sense_node:
name: sense_node
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: sense_node
description: Node to be monitored for voltage control in remote sense mode
comments:
- 'Import: REMOTE_NODE must name the regulator''s own to bus, as OUTPUT_VOLTAGE
(the control''s Terminal is end 2); elsewhere raises. Export: not written.'
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
related_mappings:
- cim:RegulatingControl.Terminal
rank: 1000
owner: regulator
domain_of:
- regulator
range: string
required: false
regulator_resistance:
name: regulator_resistance
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: regulator_resistance[Ohm]
description: The resistance value of the regulator when it is not blown.
from_schema: https://gridlabd.org/schema/glm/powerflow/regulator
rank: 1000
owner: regulator
domain_of:
- regulator
range: float
required: false
unit:
ucum_code: Ohm
status:
name: status
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: status
comments:
- 'Import: a switch family device: Switch.open and Switch.normalOpen both true
when OPEN; unset is CLOSED, noted on the row. A line or series_reactor must
be unset or CLOSED; OPEN raises. Export: OPEN or CLOSED from the chosen switch
state.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
related_mappings:
- cim:Switch.open
- cim:Switch.normalOpen
rank: 1000
owner: regulator
domain_of:
- link
range: string
required: false
from_node:
name: from_node
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: from
description: from_node - source node
comments:
- 'Import: node1, the root bus of the object named. Export: terminal 1''s bus.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
related_mappings:
- cim:Terminal.ConnectivityNode
rank: 1000
owner: regulator
domain_of:
- link
range: string
required: false
to:
name: to
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: to
description: to_node - load node
comments:
- 'Import: node2, the root bus of the object named. Export: terminal 2''s bus.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
related_mappings:
- cim:Terminal.ConnectivityNode
rank: 1000
owner: regulator
domain_of:
- link
range: string
required: false
power_in:
name: power_in
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_in[VA]
description: power flow in (w.r.t from node)
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- inverter
range: Complex
required: false
unit:
ucum_code: VA
power_out:
name: power_out
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_out[VA]
description: power flow out (w.r.t to node)
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: VA
power_out_real:
name: power_out_real
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: power_out_real[W]
description: power flow out (w.r.t to node), real
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: float
required: false
unit:
ucum_code: W
power_losses:
name: power_losses
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_losses[VA]
description: power losses
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: VA
power_in_A:
name: power_in_A
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_in_A[VA]
description: power flow in (w.r.t from node), phase A
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: VA
power_in_B:
name: power_in_B
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_in_B[VA]
description: power flow in (w.r.t from node), phase B
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: VA
power_in_C:
name: power_in_C
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_in_C[VA]
description: power flow in (w.r.t from node), phase C
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: VA
power_out_A:
name: power_out_A
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_out_A[VA]
description: power flow out (w.r.t to node), phase A
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- diesel_dg
- rectifier
range: Complex
required: false
unit:
ucum_code: VA
power_out_B:
name: power_out_B
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_out_B[VA]
description: power flow out (w.r.t to node), phase B
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- diesel_dg
- rectifier
range: Complex
required: false
unit:
ucum_code: VA
power_out_C:
name: power_out_C
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_out_C[VA]
description: power flow out (w.r.t to node), phase C
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- diesel_dg
- rectifier
range: Complex
required: false
unit:
ucum_code: VA
power_losses_A:
name: power_losses_A
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_losses_A[VA]
description: power losses, phase A
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: VA
power_losses_B:
name: power_losses_B
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_losses_B[VA]
description: power losses, phase B
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: VA
power_losses_C:
name: power_losses_C
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_losses_C[VA]
description: power losses, phase C
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: VA
current_out_A:
name: current_out_A
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_out_A[A]
description: current flow out of link (w.r.t. to node), phase A
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- diesel_dg
range: Complex
required: false
unit:
ucum_code: A
current_out_B:
name: current_out_B
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_out_B[A]
description: current flow out of link (w.r.t. to node), phase B
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- diesel_dg
range: Complex
required: false
unit:
ucum_code: A
current_out_C:
name: current_out_C
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_out_C[A]
description: current flow out of link (w.r.t. to node), phase C
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- diesel_dg
range: Complex
required: false
unit:
ucum_code: A
current_in_A:
name: current_in_A
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_in_A[A]
description: current flow to link (w.r.t from node), phase A
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
current_in_B:
name: current_in_B
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_in_B[A]
description: current flow to link (w.r.t from node), phase B
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
current_in_C:
name: current_in_C
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_in_C[A]
description: current flow to link (w.r.t from node), phase C
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
fault_current_in_A:
name: fault_current_in_A
annotations:
order:
tag: order
value: 23
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_current_in_A[A]
description: fault current flowing in, phase A
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
fault_current_in_B:
name: fault_current_in_B
annotations:
order:
tag: order
value: 24
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_current_in_B[A]
description: fault current flowing in, phase B
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
fault_current_in_C:
name: fault_current_in_C
annotations:
order:
tag: order
value: 25
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_current_in_C[A]
description: fault current flowing in, phase C
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
fault_current_out_A:
name: fault_current_out_A
annotations:
order:
tag: order
value: 26
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_current_out_A[A]
description: fault current flowing out, phase A
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
fault_current_out_B:
name: fault_current_out_B
annotations:
order:
tag: order
value: 27
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_current_out_B[A]
description: fault current flowing out, phase B
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
fault_current_out_C:
name: fault_current_out_C
annotations:
order:
tag: order
value: 28
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_current_out_C[A]
description: fault current flowing out, phase C
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
pdispatch:
name: pdispatch
annotations:
order:
tag: order
value: 29
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pdispatch[W]
description: Scheduled flow from->to in W
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- diesel_dg
- inverter_dyn
range: float
required: false
unit:
ucum_code: W
pdispatch_offset:
name: pdispatch_offset
annotations:
order:
tag: order
value: 30
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pdispatch_offset[W]
description: Offset to scheduled flow from->to in W
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- diesel_dg
- inverter_dyn
range: float
required: false
unit:
ucum_code: W
set_pdispatch:
name: set_pdispatch
annotations:
order:
tag: order
value: 31
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: set_pdispatch
description: trigger to set pdispatch equal to (power_in + power_out)/2
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: boolean
required: false
fault_voltage_A:
name: fault_voltage_A
annotations:
order:
tag: order
value: 32
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_voltage_A[A]
description: fault voltage, phase A
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
fault_voltage_B:
name: fault_voltage_B
annotations:
order:
tag: order
value: 33
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_voltage_B[A]
description: fault voltage, phase B
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
fault_voltage_C:
name: fault_voltage_C
annotations:
order:
tag: order
value: 34
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: fault_voltage_C[A]
description: fault voltage, phase C
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
unit:
ucum_code: A
overloaded_status:
name: overloaded_status
annotations:
order:
tag: order
value: 35
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: overloaded_status
description: overloaded status (true/false)
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: boolean
required: false
flow_direction:
name: flow_direction
annotations:
order:
tag: order
value: 36
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: flow_direction
description: flag used for describing direction of the flow of power
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: string
required: false
mean_repair_time:
name: mean_repair_time
annotations:
order:
tag: order
value: 37
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mean_repair_time[s]
description: Time after a fault clears for the object to be back in service
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- node
range: float
required: false
unit:
ucum_code: s
continuous_rating_A:
name: continuous_rating_A
annotations:
order:
tag: order
value: 38
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: continuous_rating_A[A]
description: Continuous rating for phase A of this link object (set individual
line segments)
comments:
- 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
normal, written on each phase of the equipment.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
close_mappings:
- cim:CurrentLimit.normalValue
rank: 1000
owner: regulator
domain_of:
- link
range: float
required: false
unit:
ucum_code: A
continuous_rating_B:
name: continuous_rating_B
annotations:
order:
tag: order
value: 39
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: continuous_rating_B[A]
description: Continuous rating for phase B of this link object (set individual
line segments)
comments:
- 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
normal, written on each phase of the equipment.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
close_mappings:
- cim:CurrentLimit.normalValue
rank: 1000
owner: regulator
domain_of:
- link
range: float
required: false
unit:
ucum_code: A
continuous_rating_C:
name: continuous_rating_C
annotations:
order:
tag: order
value: 40
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: continuous_rating_C[A]
description: Continuous rating for phase C of this link object (set individual
line segments)
comments:
- 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
normal, written on each phase of the equipment.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
close_mappings:
- cim:CurrentLimit.normalValue
rank: 1000
owner: regulator
domain_of:
- link
range: float
required: false
unit:
ucum_code: A
emergency_rating_A:
name: emergency_rating_A
annotations:
order:
tag: order
value: 41
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: emergency_rating_A[A]
description: Emergency rating for phase A of this link object (set individual
line segments)
comments:
- 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
emergency, written on each phase of the equipment.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
close_mappings:
- cim:CurrentLimit.normalValue
rank: 1000
owner: regulator
domain_of:
- link
range: float
required: false
unit:
ucum_code: A
emergency_rating_B:
name: emergency_rating_B
annotations:
order:
tag: order
value: 42
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: emergency_rating_B[A]
description: Emergency rating for phase B of this link object (set individual
line segments)
comments:
- 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
emergency, written on each phase of the equipment.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
close_mappings:
- cim:CurrentLimit.normalValue
rank: 1000
owner: regulator
domain_of:
- link
range: float
required: false
unit:
ucum_code: A
emergency_rating_C:
name: emergency_rating_C
annotations:
order:
tag: order
value: 43
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: emergency_rating_C[A]
description: Emergency rating for phase C of this link object (set individual
line segments)
comments:
- 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
emergency, written on each phase of the equipment.'
from_schema: https://gridlabd.org/schema/glm/powerflow/link
close_mappings:
- cim:CurrentLimit.normalValue
rank: 1000
owner: regulator
domain_of:
- link
range: float
required: false
unit:
ucum_code: A
inrush_convergence_value:
name: inrush_convergence_value
annotations:
order:
tag: order
value: 44
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: inrush_convergence_value[V]
description: Tolerance, as change in line voltage drop between iterations, for
deltamode in-rush completion
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: float
required: false
unit:
ucum_code: V
triplex_neutral_1_value:
name: triplex_neutral_1_value
annotations:
order:
tag: order
value: 45
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: triplex_neutral_1_value
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
triplex_neutral_2_value:
name: triplex_neutral_2_value
annotations:
order:
tag: order
value: 46
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: triplex_neutral_2_value
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
range: Complex
required: false
inrush_integration_method_capacitance:
name: inrush_integration_method_capacitance
annotations:
order:
tag: order
value: 47
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: inrush_integration_method_capacitance
description: Selected integration method to use for capacitive elements of the
link
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- load
range: InrushIntegrationMethodCapacitance
required: false
inrush_integration_method_inductance:
name: inrush_integration_method_inductance
annotations:
order:
tag: order
value: 48
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: inrush_integration_method_inductance
description: Selected integration method to use for inductive elements of the
link
from_schema: https://gridlabd.org/schema/glm/powerflow/link
rank: 1000
owner: regulator
domain_of:
- link
- load
range: InrushIntegrationMethodInductance
required: false
phases:
name: phases
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: phases
comments:
- 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
bus); a switch or reactor side 1''s A, B, C.'
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
related_mappings:
- cim:Terminal.phases
rank: 1000
owner: regulator
domain_of:
- powerflow_object
- inverter
- rectifier
- windturb_dg
range: string
required: false
nominal_voltage:
name: nominal_voltage
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: nominal_voltage[V]
comments:
- 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
(V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
/ sqrt 3.'
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
close_mappings:
- cim:BaseVoltage.nominalVoltage
- cim:EnergySource.nominalVoltage
rank: 1000
owner: regulator
domain_of:
- powerflow_object
- battery
- waterheater
range: float
required: false
unit:
ucum_code: V
inrush_integration_method:
name: inrush_integration_method
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: inrush_integration_method
description: Integration method for in-rush
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
rank: 1000
owner: regulator
domain_of:
- powerflow_object
range: string
required: false
condition:
name: condition
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: condition
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
rank: 1000
owner: regulator
domain_of:
- powerflow_object
range: string
required: false
solution:
name: solution
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: solution
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
rank: 1000
owner: regulator
domain_of:
- powerflow_object
range: string
required: false
name:
name: name
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: name
description: The object's name; unique across the model.
comments:
- 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
(none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
share raises.'
from_schema: https://gridlabd.org/schema/glm/types/common
exact_mappings:
- cim:IdentifiedObject.name
rank: 1000
identifier: true
owner: regulator
domain_of:
- glm_object
range: string
required: true
parent:
name: parent
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: parent
description: The parent object's name. A child node is solved as its parent's
bus; a nested object block sets it to the enclosing object.
comments:
- 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
on the root''s row; no object of its own. On a link it is not mapped.'
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: regulator
domain_of:
- glm_object
range: string
groupid:
name: groupid
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: groupid
description: Free-text group label.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: regulator
domain_of:
- glm_object
range: string
latitude:
name: latitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: latitude
description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: regulator
domain_of:
- glm_object
range: string
longitude:
name: longitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: longitude
description: Longitude, as written.
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: regulator
domain_of:
- glm_object
range: string
in_svc:
name: in_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: in_svc
description: Timestamp the object enters service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: regulator
domain_of:
- glm_object
range: string
out_svc:
name: out_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: out_svc
description: Timestamp the object leaves service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: regulator
domain_of:
- glm_object
range: string
rank:
name: rank
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: rank
description: Solver rank.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: regulator
domain_of:
- glm_object
range: string
flags:
name: flags
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: flags
description: Core object flags.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: regulator
domain_of:
- glm_object
range: string