Class: Transformer

Copyright (C) 2008 Battelle Memorial Institute

@file transformer.cpp

@addtogroup powerflow_transformer Transformer

@ingroup powerflow

The transformer is one of the more complex objects in the powerflow

network. Implemented as a link, the transformer configuration exports a type

property that allows the transformer to operate as and single phase transformer,

a wye-wye connected transformer, a delta-grounded wye tranformer, a delta-delta

transformer, and as a center-tapped transformer.

The transformer exports a phase property that is a set of phases and may

be set using the bitwise or operator (A|B|C for a 3 phase line).

@{

__

Inherits from: link

__

Type: Instance (network topology element)

URI: glm:Transformer

 classDiagram
    class Transformer
    click Transformer href "../Transformer/"
      Link <|-- Transformer
        click Link href "../Link/"

      Transformer : aging_constant

      Transformer : aging_granularity

      Transformer : ambient_temperature

      Transformer : climate

      Transformer : condition

      Transformer : configuration

      Transformer : continuous_rating_A

      Transformer : continuous_rating_B

      Transformer : continuous_rating_C

      Transformer : current_in_A





        Transformer --> "0..1" Complex : current_in_A
        click Complex href "../Complex/"



      Transformer : current_in_B





        Transformer --> "0..1" Complex : current_in_B
        click Complex href "../Complex/"



      Transformer : current_in_C





        Transformer --> "0..1" Complex : current_in_C
        click Complex href "../Complex/"



      Transformer : current_out_A





        Transformer --> "0..1" Complex : current_out_A
        click Complex href "../Complex/"



      Transformer : current_out_B





        Transformer --> "0..1" Complex : current_out_B
        click Complex href "../Complex/"



      Transformer : current_out_C





        Transformer --> "0..1" Complex : current_out_C
        click Complex href "../Complex/"



      Transformer : emergency_rating_A

      Transformer : emergency_rating_B

      Transformer : emergency_rating_C

      Transformer : fault_current_in_A





        Transformer --> "0..1" Complex : fault_current_in_A
        click Complex href "../Complex/"



      Transformer : fault_current_in_B





        Transformer --> "0..1" Complex : fault_current_in_B
        click Complex href "../Complex/"



      Transformer : fault_current_in_C





        Transformer --> "0..1" Complex : fault_current_in_C
        click Complex href "../Complex/"



      Transformer : fault_current_out_A





        Transformer --> "0..1" Complex : fault_current_out_A
        click Complex href "../Complex/"



      Transformer : fault_current_out_B





        Transformer --> "0..1" Complex : fault_current_out_B
        click Complex href "../Complex/"



      Transformer : fault_current_out_C





        Transformer --> "0..1" Complex : fault_current_out_C
        click Complex href "../Complex/"



      Transformer : fault_voltage_A





        Transformer --> "0..1" Complex : fault_voltage_A
        click Complex href "../Complex/"



      Transformer : fault_voltage_B





        Transformer --> "0..1" Complex : fault_voltage_B
        click Complex href "../Complex/"



      Transformer : fault_voltage_C





        Transformer --> "0..1" Complex : fault_voltage_C
        click Complex href "../Complex/"



      Transformer : flags

      Transformer : flow_direction

      Transformer : from_node

      Transformer : groupid

      Transformer : in_svc

      Transformer : inrush_convergence_value

      Transformer : inrush_integration_method

      Transformer : inrush_integration_method_capacitance





        Transformer --> "0..1" InrushIntegrationMethodCapacitance : inrush_integration_method_capacitance
        click InrushIntegrationMethodCapacitance href "../InrushIntegrationMethodCapacitance/"



      Transformer : inrush_integration_method_inductance





        Transformer --> "0..1" InrushIntegrationMethodInductance : inrush_integration_method_inductance
        click InrushIntegrationMethodInductance href "../InrushIntegrationMethodInductance/"



      Transformer : latitude

      Transformer : longitude

      Transformer : mean_repair_time

      Transformer : name

      Transformer : nominal_voltage

      Transformer : out_svc

      Transformer : overloaded_status

      Transformer : parent

      Transformer : pdispatch

      Transformer : pdispatch_offset

      Transformer : percent_loss_of_life

      Transformer : phase_A_primary_flux_value

      Transformer : phase_A_secondary_flux_value

      Transformer : phase_B_primary_flux_value

      Transformer : phase_B_secondary_flux_value

      Transformer : phase_C_primary_flux_value

      Transformer : phase_C_secondary_flux_value

      Transformer : phases

      Transformer : power_in





        Transformer --> "0..1" Complex : power_in
        click Complex href "../Complex/"



      Transformer : power_in_A





        Transformer --> "0..1" Complex : power_in_A
        click Complex href "../Complex/"



      Transformer : power_in_B





        Transformer --> "0..1" Complex : power_in_B
        click Complex href "../Complex/"



      Transformer : power_in_C





        Transformer --> "0..1" Complex : power_in_C
        click Complex href "../Complex/"



      Transformer : power_losses





        Transformer --> "0..1" Complex : power_losses
        click Complex href "../Complex/"



      Transformer : power_losses_A





        Transformer --> "0..1" Complex : power_losses_A
        click Complex href "../Complex/"



      Transformer : power_losses_B





        Transformer --> "0..1" Complex : power_losses_B
        click Complex href "../Complex/"



      Transformer : power_losses_C





        Transformer --> "0..1" Complex : power_losses_C
        click Complex href "../Complex/"



      Transformer : power_out





        Transformer --> "0..1" Complex : power_out
        click Complex href "../Complex/"



      Transformer : power_out_A





        Transformer --> "0..1" Complex : power_out_A
        click Complex href "../Complex/"



      Transformer : power_out_B





        Transformer --> "0..1" Complex : power_out_B
        click Complex href "../Complex/"



      Transformer : power_out_C





        Transformer --> "0..1" Complex : power_out_C
        click Complex href "../Complex/"



      Transformer : power_out_real

      Transformer : rank

      Transformer : set_pdispatch

      Transformer : solution

      Transformer : status

      Transformer : to

      Transformer : top_oil_hot_spot_temperature

      Transformer : transformer_replacement_count

      Transformer : triplex_neutral_1_value





        Transformer --> "0..1" Complex : triplex_neutral_1_value
        click Complex href "../Complex/"



      Transformer : triplex_neutral_2_value





        Transformer --> "0..1" Complex : triplex_neutral_2_value
        click Complex href "../Complex/"



      Transformer : use_thermal_model

      Transformer : winding_hot_spot_temperature

Inheritance

Slots

Name Cardinality and Range Description Inheritance
configuration 0..1
String
Configuration library used for transformer setup direct
climate 0..1
String
climate object used to describe thermal model ambient temperature direct
ambient_temperature 0..1
Float
ambient temperature in degrees C direct
top_oil_hot_spot_temperature 0..1
Float
top-oil hottest-spot temperature, degrees C direct
winding_hot_spot_temperature 0..1
Float
winding hottest-spot temperature, degrees C direct
percent_loss_of_life 0..1
Float
the percent loss of life direct
aging_constant 0..1
Float
the aging rate slope for the transformer insulation direct
use_thermal_model 0..1
Boolean
boolean to enable use of thermal model direct
transformer_replacement_count 0..1
Float
counter of the number times the transformer has been replaced due to lifetime... direct
aging_granularity 0..1
Float
maximum timestep before updating thermal and aging model in seconds direct
phase_A_primary_flux_value 0..1
Float
instantaneous magnetic flux in phase A on the primary side of the transformer... direct
phase_B_primary_flux_value 0..1
Float
instantaneous magnetic flux in phase B on the primary side of the transformer... direct
phase_C_primary_flux_value 0..1
Float
instantaneous magnetic flux in phase C on the primary side of the transformer... direct
phase_A_secondary_flux_value 0..1
Float
instantaneous magnetic flux in phase A on the secondary side of the transform... direct
phase_B_secondary_flux_value 0..1
Float
instantaneous magnetic flux in phase B on the secondary side of the transform... direct
phase_C_secondary_flux_value 0..1
Float
instantaneous magnetic flux in phase C on the secondary side of the transform... direct
status 0..1
String
Link
from_node 0..1
String
from_node - source node Link
to 0..1
String
to_node - load node Link
power_in 0..1
Complex
power flow in (w Link
power_out 0..1
Complex
power flow out (w Link
power_out_real 0..1
Float
power flow out (w Link
power_losses 0..1
Complex
power losses Link
power_in_A 0..1
Complex
power flow in (w Link
power_in_B 0..1
Complex
power flow in (w Link
power_in_C 0..1
Complex
power flow in (w Link
power_out_A 0..1
Complex
power flow out (w Link
power_out_B 0..1
Complex
power flow out (w Link
power_out_C 0..1
Complex
power flow out (w Link
power_losses_A 0..1
Complex
power losses, phase A Link
power_losses_B 0..1
Complex
power losses, phase B Link
power_losses_C 0..1
Complex
power losses, phase C Link
current_out_A 0..1
Complex
current flow out of link (w Link
current_out_B 0..1
Complex
current flow out of link (w Link
current_out_C 0..1
Complex
current flow out of link (w Link
current_in_A 0..1
Complex
current flow to link (w Link
current_in_B 0..1
Complex
current flow to link (w Link
current_in_C 0..1
Complex
current flow to link (w Link
fault_current_in_A 0..1
Complex
fault current flowing in, phase A Link
fault_current_in_B 0..1
Complex
fault current flowing in, phase B Link
fault_current_in_C 0..1
Complex
fault current flowing in, phase C Link
fault_current_out_A 0..1
Complex
fault current flowing out, phase A Link
fault_current_out_B 0..1
Complex
fault current flowing out, phase B Link
fault_current_out_C 0..1
Complex
fault current flowing out, phase C Link
pdispatch 0..1
Float
Scheduled flow from->to in W Link
pdispatch_offset 0..1
Float
Offset to scheduled flow from->to in W Link
set_pdispatch 0..1
Boolean
trigger to set pdispatch equal to (power_in + power_out)/2 Link
fault_voltage_A 0..1
Complex
fault voltage, phase A Link
fault_voltage_B 0..1
Complex
fault voltage, phase B Link
fault_voltage_C 0..1
Complex
fault voltage, phase C Link
overloaded_status 0..1
Boolean
overloaded status (true/false) Link
flow_direction 0..1
String
flag used for describing direction of the flow of power Link
mean_repair_time 0..1
Float
Time after a fault clears for the object to be back in service Link
continuous_rating_A 0..1
Float
Continuous rating for phase A of this link object (set individual line segmen... Link
continuous_rating_B 0..1
Float
Continuous rating for phase B of this link object (set individual line segmen... Link
continuous_rating_C 0..1
Float
Continuous rating for phase C of this link object (set individual line segmen... Link
emergency_rating_A 0..1
Float
Emergency rating for phase A of this link object (set individual line segment... Link
emergency_rating_B 0..1
Float
Emergency rating for phase B of this link object (set individual line segment... Link
emergency_rating_C 0..1
Float
Emergency rating for phase C of this link object (set individual line segment... Link
inrush_convergence_value 0..1
Float
Tolerance, as change in line voltage drop between iterations, for deltamode i... Link
triplex_neutral_1_value 0..1
Complex
Link
triplex_neutral_2_value 0..1
Complex
Link
inrush_integration_method_capacitance 0..1
InrushIntegrationMethodCapacitance
Selected integration method to use for capacitive elements of the link Link
inrush_integration_method_inductance 0..1
InrushIntegrationMethodInductance
Selected integration method to use for inductive elements of the link Link
phases 0..1
String
PowerflowObject
nominal_voltage 0..1
Float
PowerflowObject
inrush_integration_method 0..1
String
Integration method for in-rush PowerflowObject
condition 0..1
String
PowerflowObject
solution 0..1
String
PowerflowObject
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: PowerTransformer, mRID xf_ + name (transformer.cimtbl), with a TransformerTank per tank of its configuration, a PowerTransformerEnd per side and a TransformerPhaseEnd per lugged conductor. Export: PowerTransformer, and an AutoTransformer that is not a VoltageRegulator, are written as it.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:Transformer
native glm:Transformer
exact cim:PowerTransformer
close cim:AutoTransformer

LinkML Source

Direct

name: transformer
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file transformer.cpp

  @addtogroup powerflow_transformer Transformer

  @ingroup powerflow

  The transformer is one of the more complex objects in the powerflow

  network. Implemented as a link, the transformer configuration exports a type

  property that allows the transformer to operate as and single phase transformer,

  a wye-wye connected transformer, a delta-grounded wye tranformer, a delta-delta

  transformer, and as a center-tapped transformer.

  The transformer exports a phase property that is a set of phases and may

  be set using the bitwise or operator (A|B|C for a 3 phase line).

  @{


  Inherits from: link


  Type: Instance (network topology element)'
comments:
- 'Import: PowerTransformer, mRID xf_ + name (transformer.cimtbl), with a TransformerTank
  per tank of its configuration, a PowerTransformerEnd per side and a TransformerPhaseEnd
  per lugged conductor. Export: PowerTransformer, and an AutoTransformer that is not
  a VoltageRegulator, are written as it.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PowerTransformer
close_mappings:
- cim:AutoTransformer
is_a: link
attributes:
  configuration:
    name: configuration
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: configuration
    description: Configuration library used for transformer setup
    comments:
    - 'Import: TransformerTank.TankConfiguration = xc_ + configuration (a bank: one
      tank per can, xc_ + configuration + _<phase>). Export: the unit''s tank configuration,
      written as its transformer_configuration.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    related_mappings:
    - cim:TransformerTank.TankConfiguration
    domain_of:
    - line
    - regulator
    - transformer
    - residential_enduse
    range: string
    required: false
  climate:
    name: climate
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: climate
    description: climate object used to describe thermal model ambient temperature
    comments:
    - 'Thermal aging model: not converted. Import lists any value in the row comment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: string
    required: false
  ambient_temperature:
    name: ambient_temperature
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ambient_temperature[degC]
    description: ambient temperature in degrees C
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    - solar
    range: float
    required: false
    unit:
      ucum_code: degC
  top_oil_hot_spot_temperature:
    name: top_oil_hot_spot_temperature
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: top_oil_hot_spot_temperature[degC]
    description: top-oil hottest-spot temperature, degrees C
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: degC
  winding_hot_spot_temperature:
    name: winding_hot_spot_temperature
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: winding_hot_spot_temperature[degC]
    description: winding hottest-spot temperature, degrees C
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: degC
  percent_loss_of_life:
    name: percent_loss_of_life
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: percent_loss_of_life
    description: the percent loss of life
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
  aging_constant:
    name: aging_constant
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: aging_constant
    description: the aging rate slope for the transformer insulation
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
  use_thermal_model:
    name: use_thermal_model
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: use_thermal_model
    description: boolean to enable use of thermal model
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: boolean
    required: false
  transformer_replacement_count:
    name: transformer_replacement_count
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: transformer_replacement_count
    description: counter of the number times the transformer has been replaced due
      to lifetime failure
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
  aging_granularity:
    name: aging_granularity
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: aging_granularity[s]
    description: maximum timestep before updating thermal and aging model in seconds
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: s
  phase_A_primary_flux_value:
    name: phase_A_primary_flux_value
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_A_primary_flux_value[Wb]
    description: instantaneous magnetic flux in phase A on the primary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_B_primary_flux_value:
    name: phase_B_primary_flux_value
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_B_primary_flux_value[Wb]
    description: instantaneous magnetic flux in phase B on the primary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_C_primary_flux_value:
    name: phase_C_primary_flux_value
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_C_primary_flux_value[Wb]
    description: instantaneous magnetic flux in phase C on the primary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_A_secondary_flux_value:
    name: phase_A_secondary_flux_value
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_A_secondary_flux_value[Wb]
    description: instantaneous magnetic flux in phase A on the secondary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_B_secondary_flux_value:
    name: phase_B_secondary_flux_value
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_B_secondary_flux_value[Wb]
    description: instantaneous magnetic flux in phase B on the secondary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_C_secondary_flux_value:
    name: phase_C_secondary_flux_value
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_C_secondary_flux_value[Wb]
    description: instantaneous magnetic flux in phase C on the secondary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb

Induced

name: transformer
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file transformer.cpp

  @addtogroup powerflow_transformer Transformer

  @ingroup powerflow

  The transformer is one of the more complex objects in the powerflow

  network. Implemented as a link, the transformer configuration exports a type

  property that allows the transformer to operate as and single phase transformer,

  a wye-wye connected transformer, a delta-grounded wye tranformer, a delta-delta

  transformer, and as a center-tapped transformer.

  The transformer exports a phase property that is a set of phases and may

  be set using the bitwise or operator (A|B|C for a 3 phase line).

  @{


  Inherits from: link


  Type: Instance (network topology element)'
comments:
- 'Import: PowerTransformer, mRID xf_ + name (transformer.cimtbl), with a TransformerTank
  per tank of its configuration, a PowerTransformerEnd per side and a TransformerPhaseEnd
  per lugged conductor. Export: PowerTransformer, and an AutoTransformer that is not
  a VoltageRegulator, are written as it.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PowerTransformer
close_mappings:
- cim:AutoTransformer
is_a: link
attributes:
  configuration:
    name: configuration
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: configuration
    description: Configuration library used for transformer setup
    comments:
    - 'Import: TransformerTank.TankConfiguration = xc_ + configuration (a bank: one
      tank per can, xc_ + configuration + _<phase>). Export: the unit''s tank configuration,
      written as its transformer_configuration.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    related_mappings:
    - cim:TransformerTank.TankConfiguration
    owner: transformer
    domain_of:
    - line
    - regulator
    - transformer
    - residential_enduse
    range: string
    required: false
  climate:
    name: climate
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: climate
    description: climate object used to describe thermal model ambient temperature
    comments:
    - 'Thermal aging model: not converted. Import lists any value in the row comment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: string
    required: false
  ambient_temperature:
    name: ambient_temperature
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ambient_temperature[degC]
    description: ambient temperature in degrees C
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    - solar
    range: float
    required: false
    unit:
      ucum_code: degC
  top_oil_hot_spot_temperature:
    name: top_oil_hot_spot_temperature
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: top_oil_hot_spot_temperature[degC]
    description: top-oil hottest-spot temperature, degrees C
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: degC
  winding_hot_spot_temperature:
    name: winding_hot_spot_temperature
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: winding_hot_spot_temperature[degC]
    description: winding hottest-spot temperature, degrees C
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: degC
  percent_loss_of_life:
    name: percent_loss_of_life
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: percent_loss_of_life
    description: the percent loss of life
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
  aging_constant:
    name: aging_constant
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: aging_constant
    description: the aging rate slope for the transformer insulation
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
  use_thermal_model:
    name: use_thermal_model
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: use_thermal_model
    description: boolean to enable use of thermal model
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: boolean
    required: false
  transformer_replacement_count:
    name: transformer_replacement_count
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: transformer_replacement_count
    description: counter of the number times the transformer has been replaced due
      to lifetime failure
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
  aging_granularity:
    name: aging_granularity
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: aging_granularity[s]
    description: maximum timestep before updating thermal and aging model in seconds
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: s
  phase_A_primary_flux_value:
    name: phase_A_primary_flux_value
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_A_primary_flux_value[Wb]
    description: instantaneous magnetic flux in phase A on the primary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_B_primary_flux_value:
    name: phase_B_primary_flux_value
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_B_primary_flux_value[Wb]
    description: instantaneous magnetic flux in phase B on the primary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_C_primary_flux_value:
    name: phase_C_primary_flux_value
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_C_primary_flux_value[Wb]
    description: instantaneous magnetic flux in phase C on the primary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_A_secondary_flux_value:
    name: phase_A_secondary_flux_value
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_A_secondary_flux_value[Wb]
    description: instantaneous magnetic flux in phase A on the secondary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_B_secondary_flux_value:
    name: phase_B_secondary_flux_value
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_B_secondary_flux_value[Wb]
    description: instantaneous magnetic flux in phase B on the secondary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  phase_C_secondary_flux_value:
    name: phase_C_secondary_flux_value
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: phase_C_secondary_flux_value[Wb]
    description: instantaneous magnetic flux in phase C on the secondary side of the
      transformer during saturation calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/transformer
    rank: 1000
    owner: transformer
    domain_of:
    - transformer
    range: float
    required: false
    unit:
      ucum_code: Wb
  status:
    name: status
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: status
    comments:
    - 'Import: a switch family device: Switch.open and Switch.normalOpen both true
      when OPEN; unset is CLOSED, noted on the row. A line or series_reactor must
      be unset or CLOSED; OPEN raises. Export: OPEN or CLOSED from the chosen switch
      state.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Switch.open
    - cim:Switch.normalOpen
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: string
    required: false
  from_node:
    name: from_node
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: from
    description: from_node - source node
    comments:
    - 'Import: node1, the root bus of the object named. Export: terminal 1''s bus.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Terminal.ConnectivityNode
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: string
    required: false
  to:
    name: to
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: to
    description: to_node - load node
    comments:
    - 'Import: node2, the root bus of the object named. Export: terminal 2''s bus.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    related_mappings:
    - cim:Terminal.ConnectivityNode
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: string
    required: false
  power_in:
    name: power_in
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in[VA]
    description: power flow in (w.r.t from node)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out:
    name: power_out
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out[VA]
    description: power flow out (w.r.t to node)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_real:
    name: power_out_real
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_out_real[W]
    description: power flow out (w.r.t to node), real
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: W
  power_losses:
    name: power_losses
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses[VA]
    description: power losses
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_A:
    name: power_in_A
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_A[VA]
    description: power flow in (w.r.t from node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_B:
    name: power_in_B
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_B[VA]
    description: power flow in (w.r.t from node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_in_C:
    name: power_in_C
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_in_C[VA]
    description: power flow in (w.r.t from node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_A:
    name: power_out_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_A[VA]
    description: power flow out (w.r.t to node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_B:
    name: power_out_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_B[VA]
    description: power flow out (w.r.t to node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_out_C:
    name: power_out_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_out_C[VA]
    description: power flow out (w.r.t to node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - diesel_dg
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_A:
    name: power_losses_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_A[VA]
    description: power losses, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_B:
    name: power_losses_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_B[VA]
    description: power losses, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_losses_C:
    name: power_losses_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_losses_C[VA]
    description: power losses, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: VA
  current_out_A:
    name: current_out_A
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_A[A]
    description: current flow out of link (w.r.t. to node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_out_B:
    name: current_out_B
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_B[A]
    description: current flow out of link (w.r.t. to node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_out_C:
    name: current_out_C
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_out_C[A]
    description: current flow out of link (w.r.t. to node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - diesel_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_A:
    name: current_in_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_A[A]
    description: current flow to link (w.r.t from node), phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_B:
    name: current_in_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_B[A]
    description: current flow to link (w.r.t from node), phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_in_C:
    name: current_in_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_in_C[A]
    description: current flow to link (w.r.t from node), phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_A:
    name: fault_current_in_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_A[A]
    description: fault current flowing in, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_B:
    name: fault_current_in_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_B[A]
    description: fault current flowing in, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_in_C:
    name: fault_current_in_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_in_C[A]
    description: fault current flowing in, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_A:
    name: fault_current_out_A
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_A[A]
    description: fault current flowing out, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_B:
    name: fault_current_out_B
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_B[A]
    description: fault current flowing out, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_current_out_C:
    name: fault_current_out_C
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_current_out_C[A]
    description: fault current flowing out, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  pdispatch:
    name: pdispatch
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pdispatch[W]
    description: Scheduled flow from->to in W
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - diesel_dg
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: W
  pdispatch_offset:
    name: pdispatch_offset
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pdispatch_offset[W]
    description: Offset to scheduled flow from->to in W
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - diesel_dg
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: W
  set_pdispatch:
    name: set_pdispatch
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: set_pdispatch
    description: trigger to set pdispatch equal to (power_in + power_out)/2
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: boolean
    required: false
  fault_voltage_A:
    name: fault_voltage_A
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_A[A]
    description: fault voltage, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_voltage_B:
    name: fault_voltage_B
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_B[A]
    description: fault voltage, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  fault_voltage_C:
    name: fault_voltage_C
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: fault_voltage_C[A]
    description: fault voltage, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
    unit:
      ucum_code: A
  overloaded_status:
    name: overloaded_status
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: overloaded_status
    description: overloaded status (true/false)
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: boolean
    required: false
  flow_direction:
    name: flow_direction
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flow_direction
    description: flag used for describing direction of the flow of power
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: string
    required: false
  mean_repair_time:
    name: mean_repair_time
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mean_repair_time[s]
    description: Time after a fault clears for the object to be back in service
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - node
    range: float
    required: false
    unit:
      ucum_code: s
  continuous_rating_A:
    name: continuous_rating_A
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_A[A]
    description: Continuous rating for phase A of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  continuous_rating_B:
    name: continuous_rating_B
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_B[A]
    description: Continuous rating for phase B of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  continuous_rating_C:
    name: continuous_rating_C
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: continuous_rating_C[A]
    description: Continuous rating for phase C of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the normal limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      normal, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_A:
    name: emergency_rating_A
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_A[A]
    description: Emergency rating for phase A of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_B:
    name: emergency_rating_B
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_B[A]
    description: Emergency rating for phase B of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  emergency_rating_C:
    name: emergency_rating_C
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: emergency_rating_C[A]
    description: Emergency rating for phase C of this link object (set individual
      line segments)
    comments:
    - 'Import: CurrentLimit.normalValue (A) of the emergency limit on the equipment''s
      own OperationalLimitSet; the set phases must agree or it raises. Export: get_current_limits
      emergency, written on each phase of the equipment.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    close_mappings:
    - cim:CurrentLimit.normalValue
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: A
  inrush_convergence_value:
    name: inrush_convergence_value
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: inrush_convergence_value[V]
    description: Tolerance, as change in line voltage drop between iterations, for
      deltamode in-rush completion
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: float
    required: false
    unit:
      ucum_code: V
  triplex_neutral_1_value:
    name: triplex_neutral_1_value
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: triplex_neutral_1_value
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
  triplex_neutral_2_value:
    name: triplex_neutral_2_value
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: triplex_neutral_2_value
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    range: Complex
    required: false
  inrush_integration_method_capacitance:
    name: inrush_integration_method_capacitance
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method_capacitance
    description: Selected integration method to use for capacitive elements of the
      link
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - load
    range: InrushIntegrationMethodCapacitance
    required: false
  inrush_integration_method_inductance:
    name: inrush_integration_method_inductance
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method_inductance
    description: Selected integration method to use for inductive elements of the
      link
    from_schema: https://gridlabd.org/schema/glm/powerflow/link
    rank: 1000
    owner: transformer
    domain_of:
    - link
    - load
    range: InrushIntegrationMethodInductance
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    comments:
    - 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
      Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
      Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
      when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
      bus); a switch or reactor side 1''s A, B, C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    related_mappings:
    - cim:Terminal.phases
    rank: 1000
    owner: transformer
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  nominal_voltage:
    name: nominal_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_voltage[V]
    comments:
    - 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
      over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
      (V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
      LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
      / sqrt 3.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    close_mappings:
    - cim:BaseVoltage.nominalVoltage
    - cim:EnergySource.nominalVoltage
    rank: 1000
    owner: transformer
    domain_of:
    - powerflow_object
    - battery
    - waterheater
    range: float
    required: false
    unit:
      ucum_code: V
  inrush_integration_method:
    name: inrush_integration_method
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method
    description: Integration method for in-rush
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: transformer
    domain_of:
    - powerflow_object
    range: string
    required: false
  condition:
    name: condition
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: condition
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: transformer
    domain_of:
    - powerflow_object
    range: string
    required: false
  solution:
    name: solution
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: solution
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: transformer
    domain_of:
    - powerflow_object
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: transformer
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: transformer
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: transformer
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: transformer
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: transformer
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: transformer
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: transformer
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: transformer
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: transformer
    domain_of:
    - glm_object
    range: string