Skip to content

Class: Pqload

Copyright (C) 2008 Battelle Memorial Institute

@file pqload.cpp

@addtogroup pqload

@ingroup node

Load objects represent static loads and export both voltages and

current.

@{

__

Inherits from: load

__

Type: Instance (network topology element)

URI: glm:Pqload

 classDiagram
    class Pqload
    click Pqload href "../Pqload/"
      Load <|-- Pqload
        click Load href "../Load/"

      Pqload : base_power_A

      Pqload : base_power_B

      Pqload : base_power_C

      Pqload : behaving_as_swing

      Pqload : busflags

      Pqload : bustype

      Pqload : condition

      Pqload : constant_current_A





        Pqload --> "0..1" Complex : constant_current_A
        click Complex href "../Complex/"



      Pqload : constant_current_A_reac

      Pqload : constant_current_A_real

      Pqload : constant_current_AB





        Pqload --> "0..1" Complex : constant_current_AB
        click Complex href "../Complex/"



      Pqload : constant_current_AB_reac

      Pqload : constant_current_AB_real

      Pqload : constant_current_AN





        Pqload --> "0..1" Complex : constant_current_AN
        click Complex href "../Complex/"



      Pqload : constant_current_AN_reac

      Pqload : constant_current_AN_real

      Pqload : constant_current_B





        Pqload --> "0..1" Complex : constant_current_B
        click Complex href "../Complex/"



      Pqload : constant_current_B_reac

      Pqload : constant_current_B_real

      Pqload : constant_current_BC





        Pqload --> "0..1" Complex : constant_current_BC
        click Complex href "../Complex/"



      Pqload : constant_current_BC_reac

      Pqload : constant_current_BC_real

      Pqload : constant_current_BN





        Pqload --> "0..1" Complex : constant_current_BN
        click Complex href "../Complex/"



      Pqload : constant_current_BN_reac

      Pqload : constant_current_BN_real

      Pqload : constant_current_C





        Pqload --> "0..1" Complex : constant_current_C
        click Complex href "../Complex/"



      Pqload : constant_current_C_reac

      Pqload : constant_current_C_real

      Pqload : constant_current_CA





        Pqload --> "0..1" Complex : constant_current_CA
        click Complex href "../Complex/"



      Pqload : constant_current_CA_reac

      Pqload : constant_current_CA_real

      Pqload : constant_current_CN





        Pqload --> "0..1" Complex : constant_current_CN
        click Complex href "../Complex/"



      Pqload : constant_current_CN_reac

      Pqload : constant_current_CN_real

      Pqload : constant_impedance_A





        Pqload --> "0..1" Complex : constant_impedance_A
        click Complex href "../Complex/"



      Pqload : constant_impedance_A_reac

      Pqload : constant_impedance_A_real

      Pqload : constant_impedance_AB





        Pqload --> "0..1" Complex : constant_impedance_AB
        click Complex href "../Complex/"



      Pqload : constant_impedance_AB_reac

      Pqload : constant_impedance_AB_real

      Pqload : constant_impedance_AN





        Pqload --> "0..1" Complex : constant_impedance_AN
        click Complex href "../Complex/"



      Pqload : constant_impedance_AN_reac

      Pqload : constant_impedance_AN_real

      Pqload : constant_impedance_B





        Pqload --> "0..1" Complex : constant_impedance_B
        click Complex href "../Complex/"



      Pqload : constant_impedance_B_reac

      Pqload : constant_impedance_B_real

      Pqload : constant_impedance_BC





        Pqload --> "0..1" Complex : constant_impedance_BC
        click Complex href "../Complex/"



      Pqload : constant_impedance_BC_reac

      Pqload : constant_impedance_BC_real

      Pqload : constant_impedance_BN





        Pqload --> "0..1" Complex : constant_impedance_BN
        click Complex href "../Complex/"



      Pqload : constant_impedance_BN_reac

      Pqload : constant_impedance_BN_real

      Pqload : constant_impedance_C





        Pqload --> "0..1" Complex : constant_impedance_C
        click Complex href "../Complex/"



      Pqload : constant_impedance_C_reac

      Pqload : constant_impedance_C_real

      Pqload : constant_impedance_CA





        Pqload --> "0..1" Complex : constant_impedance_CA
        click Complex href "../Complex/"



      Pqload : constant_impedance_CA_reac

      Pqload : constant_impedance_CA_real

      Pqload : constant_impedance_CN





        Pqload --> "0..1" Complex : constant_impedance_CN
        click Complex href "../Complex/"



      Pqload : constant_impedance_CN_reac

      Pqload : constant_impedance_CN_real

      Pqload : constant_power_A





        Pqload --> "0..1" Complex : constant_power_A
        click Complex href "../Complex/"



      Pqload : constant_power_A_reac

      Pqload : constant_power_A_real

      Pqload : constant_power_AB





        Pqload --> "0..1" Complex : constant_power_AB
        click Complex href "../Complex/"



      Pqload : constant_power_AB_reac

      Pqload : constant_power_AB_real

      Pqload : constant_power_AN





        Pqload --> "0..1" Complex : constant_power_AN
        click Complex href "../Complex/"



      Pqload : constant_power_AN_reac

      Pqload : constant_power_AN_real

      Pqload : constant_power_B





        Pqload --> "0..1" Complex : constant_power_B
        click Complex href "../Complex/"



      Pqload : constant_power_B_reac

      Pqload : constant_power_B_real

      Pqload : constant_power_BC





        Pqload --> "0..1" Complex : constant_power_BC
        click Complex href "../Complex/"



      Pqload : constant_power_BC_reac

      Pqload : constant_power_BC_real

      Pqload : constant_power_BN





        Pqload --> "0..1" Complex : constant_power_BN
        click Complex href "../Complex/"



      Pqload : constant_power_BN_reac

      Pqload : constant_power_BN_real

      Pqload : constant_power_C





        Pqload --> "0..1" Complex : constant_power_C
        click Complex href "../Complex/"



      Pqload : constant_power_C_reac

      Pqload : constant_power_C_real

      Pqload : constant_power_CA





        Pqload --> "0..1" Complex : constant_power_CA
        click Complex href "../Complex/"



      Pqload : constant_power_CA_reac

      Pqload : constant_power_CA_real

      Pqload : constant_power_CN





        Pqload --> "0..1" Complex : constant_power_CN
        click Complex href "../Complex/"



      Pqload : constant_power_CN_reac

      Pqload : constant_power_CN_real

      Pqload : current_A





        Pqload --> "0..1" Complex : current_A
        click Complex href "../Complex/"



      Pqload : current_AB





        Pqload --> "0..1" Complex : current_AB
        click Complex href "../Complex/"



      Pqload : current_AN





        Pqload --> "0..1" Complex : current_AN
        click Complex href "../Complex/"



      Pqload : current_B





        Pqload --> "0..1" Complex : current_B
        click Complex href "../Complex/"



      Pqload : current_BC





        Pqload --> "0..1" Complex : current_BC
        click Complex href "../Complex/"



      Pqload : current_BN





        Pqload --> "0..1" Complex : current_BN
        click Complex href "../Complex/"



      Pqload : current_C





        Pqload --> "0..1" Complex : current_C
        click Complex href "../Complex/"



      Pqload : current_CA





        Pqload --> "0..1" Complex : current_CA
        click Complex href "../Complex/"



      Pqload : current_CN





        Pqload --> "0..1" Complex : current_CN
        click Complex href "../Complex/"



      Pqload : current_fraction_A

      Pqload : current_fraction_B

      Pqload : current_fraction_C

      Pqload : current_inj_A





        Pqload --> "0..1" Complex : current_inj_A
        click Complex href "../Complex/"



      Pqload : current_inj_B





        Pqload --> "0..1" Complex : current_inj_B
        click Complex href "../Complex/"



      Pqload : current_inj_C





        Pqload --> "0..1" Complex : current_inj_C
        click Complex href "../Complex/"



      Pqload : current_pf_A

      Pqload : current_pf_B

      Pqload : current_pf_C

      Pqload : current_uptime

      Pqload : deltamode_full_Y_all_matrix

      Pqload : deltamode_full_Y_matrix

      Pqload : deltamode_generator_current_A





        Pqload --> "0..1" Complex : deltamode_generator_current_A
        click Complex href "../Complex/"



      Pqload : deltamode_generator_current_B





        Pqload --> "0..1" Complex : deltamode_generator_current_B
        click Complex href "../Complex/"



      Pqload : deltamode_generator_current_C





        Pqload --> "0..1" Complex : deltamode_generator_current_C
        click Complex href "../Complex/"



      Pqload : deltamode_PGenTotal





        Pqload --> "0..1" Complex : deltamode_PGenTotal
        click Complex href "../Complex/"



      Pqload : flags

      Pqload : frequency_measure_type

      Pqload : generator_dynamic

      Pqload : GFA_enable

      Pqload : GFA_freq_disconnect_time

      Pqload : GFA_freq_high_trip

      Pqload : GFA_freq_low_trip

      Pqload : GFA_reconnect_time

      Pqload : GFA_status

      Pqload : GFA_trip_method

      Pqload : GFA_volt_disconnect_time

      Pqload : GFA_volt_high_trip

      Pqload : GFA_volt_low_trip

      Pqload : groupid

      Pqload : house_present

      Pqload : Ia

      Pqload : Ia_H

      Pqload : Ia_R

      Pqload : Ia_S

      Pqload : Ia_T

      Pqload : Ia_W

      Pqload : Im

      Pqload : Im_H

      Pqload : Im_R

      Pqload : Im_S

      Pqload : Im_T

      Pqload : Im_W

      Pqload : impedance_fraction_A

      Pqload : impedance_fraction_B

      Pqload : impedance_fraction_C

      Pqload : impedance_pf_A

      Pqload : impedance_pf_B

      Pqload : impedance_pf_C

      Pqload : in_svc

      Pqload : input_humid

      Pqload : input_rain

      Pqload : input_solar

      Pqload : input_temp

      Pqload : input_wind

      Pqload : inrush_integration_method

      Pqload : inrush_integration_method_capacitance

      Pqload : inrush_integration_method_inductance

      Pqload : latitude

      Pqload : load_class

      Pqload : load_priority

      Pqload : longitude

      Pqload : maximum_voltage_error

      Pqload : mean_repair_time

      Pqload : measured_angle_A

      Pqload : measured_angle_B

      Pqload : measured_angle_C

      Pqload : measured_frequency

      Pqload : measured_frequency_A

      Pqload : measured_frequency_B

      Pqload : measured_frequency_C

      Pqload : measured_power





        Pqload --> "0..1" Complex : measured_power
        click Complex href "../Complex/"



      Pqload : measured_power_A





        Pqload --> "0..1" Complex : measured_power_A
        click Complex href "../Complex/"



      Pqload : measured_power_B





        Pqload --> "0..1" Complex : measured_power_B
        click Complex href "../Complex/"



      Pqload : measured_power_C





        Pqload --> "0..1" Complex : measured_power_C
        click Complex href "../Complex/"



      Pqload : measured_voltage_A





        Pqload --> "0..1" Complex : measured_voltage_A
        click Complex href "../Complex/"



      Pqload : measured_voltage_AB





        Pqload --> "0..1" Complex : measured_voltage_AB
        click Complex href "../Complex/"



      Pqload : measured_voltage_B





        Pqload --> "0..1" Complex : measured_voltage_B
        click Complex href "../Complex/"



      Pqload : measured_voltage_BC





        Pqload --> "0..1" Complex : measured_voltage_BC
        click Complex href "../Complex/"



      Pqload : measured_voltage_C





        Pqload --> "0..1" Complex : measured_voltage_C
        click Complex href "../Complex/"



      Pqload : measured_voltage_CA





        Pqload --> "0..1" Complex : measured_voltage_CA
        click Complex href "../Complex/"



      Pqload : name

      Pqload : nominal_voltage

      Pqload : Norton_dynamic

      Pqload : Norton_dynamic_child

      Pqload : NR_powerflow_parent

      Pqload : out_svc

      Pqload : output_current





        Pqload --> "0..1" Complex : output_current
        click Complex href "../Complex/"



      Pqload : output_current_a

      Pqload : output_current_m

      Pqload : output_imped_p

      Pqload : output_imped_q

      Pqload : output_impedance





        Pqload --> "0..1" Complex : output_impedance
        click Complex href "../Complex/"



      Pqload : output_power





        Pqload --> "0..1" Complex : output_power
        click Complex href "../Complex/"



      Pqload : output_power_p

      Pqload : output_power_q

      Pqload : parent

      Pqload : phase_loss_protection

      Pqload : phases

      Pqload : pll_Ki

      Pqload : pll_Kp

      Pqload : power_A





        Pqload --> "0..1" Complex : power_A
        click Complex href "../Complex/"



      Pqload : power_AB





        Pqload --> "0..1" Complex : power_AB
        click Complex href "../Complex/"



      Pqload : power_AN





        Pqload --> "0..1" Complex : power_AN
        click Complex href "../Complex/"



      Pqload : power_B





        Pqload --> "0..1" Complex : power_B
        click Complex href "../Complex/"



      Pqload : power_BC





        Pqload --> "0..1" Complex : power_BC
        click Complex href "../Complex/"



      Pqload : power_BN





        Pqload --> "0..1" Complex : power_BN
        click Complex href "../Complex/"



      Pqload : power_C





        Pqload --> "0..1" Complex : power_C
        click Complex href "../Complex/"



      Pqload : power_CA





        Pqload --> "0..1" Complex : power_CA
        click Complex href "../Complex/"



      Pqload : power_CN





        Pqload --> "0..1" Complex : power_CN
        click Complex href "../Complex/"



      Pqload : power_fraction_A

      Pqload : power_fraction_B

      Pqload : power_fraction_C

      Pqload : power_pf_A

      Pqload : power_pf_B

      Pqload : power_pf_C

      Pqload : Pp

      Pqload : Pp_H

      Pqload : Pp_R

      Pqload : Pp_S

      Pqload : Pp_T

      Pqload : Pp_W

      Pqload : Pq

      Pqload : Pq_H

      Pqload : Pq_R

      Pqload : Pq_S

      Pqload : Pq_T

      Pqload : Pq_W

      Pqload : prerotated_current_A





        Pqload --> "0..1" Complex : prerotated_current_A
        click Complex href "../Complex/"



      Pqload : prerotated_current_B





        Pqload --> "0..1" Complex : prerotated_current_B
        click Complex href "../Complex/"



      Pqload : prerotated_current_C





        Pqload --> "0..1" Complex : prerotated_current_C
        click Complex href "../Complex/"



      Pqload : previous_uptime

      Pqload : rank

      Pqload : reference_bus

      Pqload : reset_disabled_island_state

      Pqload : residential_nominal_current_A





        Pqload --> "0..1" Complex : residential_nominal_current_A
        click Complex href "../Complex/"



      Pqload : residential_nominal_current_A_imag

      Pqload : residential_nominal_current_A_real

      Pqload : residential_nominal_current_B





        Pqload --> "0..1" Complex : residential_nominal_current_B
        click Complex href "../Complex/"



      Pqload : residential_nominal_current_B_imag

      Pqload : residential_nominal_current_B_real

      Pqload : residential_nominal_current_C





        Pqload --> "0..1" Complex : residential_nominal_current_C
        click Complex href "../Complex/"



      Pqload : residential_nominal_current_C_imag

      Pqload : residential_nominal_current_C_real

      Pqload : service_status

      Pqload : service_status_double

      Pqload : sfm_Tf

      Pqload : shunt_A





        Pqload --> "0..1" Complex : shunt_A
        click Complex href "../Complex/"



      Pqload : shunt_AB





        Pqload --> "0..1" Complex : shunt_AB
        click Complex href "../Complex/"



      Pqload : shunt_AN





        Pqload --> "0..1" Complex : shunt_AN
        click Complex href "../Complex/"



      Pqload : shunt_B





        Pqload --> "0..1" Complex : shunt_B
        click Complex href "../Complex/"



      Pqload : shunt_BC





        Pqload --> "0..1" Complex : shunt_BC
        click Complex href "../Complex/"



      Pqload : shunt_BN





        Pqload --> "0..1" Complex : shunt_BN
        click Complex href "../Complex/"



      Pqload : shunt_C





        Pqload --> "0..1" Complex : shunt_C
        click Complex href "../Complex/"



      Pqload : shunt_CA





        Pqload --> "0..1" Complex : shunt_CA
        click Complex href "../Complex/"



      Pqload : shunt_CN





        Pqload --> "0..1" Complex : shunt_CN
        click Complex href "../Complex/"



      Pqload : solution

      Pqload : T_nominal

      Pqload : topological_parent

      Pqload : voltage_A





        Pqload --> "0..1" Complex : voltage_A
        click Complex href "../Complex/"



      Pqload : voltage_AB





        Pqload --> "0..1" Complex : voltage_AB
        click Complex href "../Complex/"



      Pqload : voltage_B





        Pqload --> "0..1" Complex : voltage_B
        click Complex href "../Complex/"



      Pqload : voltage_BC





        Pqload --> "0..1" Complex : voltage_BC
        click Complex href "../Complex/"



      Pqload : voltage_C





        Pqload --> "0..1" Complex : voltage_C
        click Complex href "../Complex/"



      Pqload : voltage_CA





        Pqload --> "0..1" Complex : voltage_CA
        click Complex href "../Complex/"



      Pqload : weather

      Pqload : Zp

      Pqload : Zp_H

      Pqload : Zp_R

      Pqload : Zp_S

      Pqload : Zp_T

      Pqload : Zp_W

      Pqload : Zq

      Pqload : Zq_H

      Pqload : Zq_R

      Pqload : Zq_S

      Pqload : Zq_T

      Pqload : Zq_W

Inheritance

Slots

Name Cardinality and Range Description Inheritance
weather 0..1
String
direct
T_nominal 0..1
Float
direct
Zp_T 0..1
Float
direct
Zp_H 0..1
Float
direct
Zp_S 0..1
Float
direct
Zp_W 0..1
Float
direct
Zp_R 0..1
Float
direct
Zp 0..1
Float
direct
Zq_T 0..1
Float
direct
Zq_H 0..1
Float
direct
Zq_S 0..1
Float
direct
Zq_W 0..1
Float
direct
Zq_R 0..1
Float
direct
Zq 0..1
Float
direct
Im_T 0..1
Float
direct
Im_H 0..1
Float
direct
Im_S 0..1
Float
direct
Im_W 0..1
Float
direct
Im_R 0..1
Float
direct
Im 0..1
Float
direct
Ia_T 0..1
Float
direct
Ia_H 0..1
Float
direct
Ia_S 0..1
Float
direct
Ia_W 0..1
Float
direct
Ia_R 0..1
Float
direct
Ia 0..1
Float
direct
Pp_T 0..1
Float
direct
Pp_H 0..1
Float
direct
Pp_S 0..1
Float
direct
Pp_W 0..1
Float
direct
Pp_R 0..1
Float
direct
Pp 0..1
Float
direct
Pq_T 0..1
Float
direct
Pq_H 0..1
Float
direct
Pq_S 0..1
Float
direct
Pq_W 0..1
Float
direct
Pq_R 0..1
Float
direct
Pq 0..1
Float
direct
input_temp 0..1
Float
direct
input_humid 0..1
Float
direct
input_solar 0..1
Float
direct
input_wind 0..1
Float
direct
input_rain 0..1
Float
direct
output_imped_p 0..1
Float
direct
output_imped_q 0..1
Float
direct
output_current_m 0..1
Float
direct
output_current_a 0..1
Float
direct
output_power_p 0..1
Float
direct
output_power_q 0..1
Float
direct
output_impedance 0..1
Complex
direct
output_current 0..1
Complex
direct
output_power 0..1
Complex
direct
load_class 0..1
String
Flag to track load type, not currently used for anything except sorting Load
load_priority 0..1
String
Load classification based on priority Load
constant_power_A 0..1
Complex
constant power load on phase A, specified as VA Load
constant_power_B 0..1
Complex
constant power load on phase B, specified as VA Load
constant_power_C 0..1
Complex
constant power load on phase C, specified as VA Load
constant_power_A_real 0..1
Float
constant power load on phase A, real only, specified as W Load
constant_power_B_real 0..1
Float
constant power load on phase B, real only, specified as W Load
constant_power_C_real 0..1
Float
constant power load on phase C, real only, specified as W Load
constant_power_A_reac 0..1
Float
constant power load on phase A, imaginary only, specified as VAr Load
constant_power_B_reac 0..1
Float
constant power load on phase B, imaginary only, specified as VAr Load
constant_power_C_reac 0..1
Float
constant power load on phase C, imaginary only, specified as VAr Load
constant_current_A 0..1
Complex
constant current load on phase A, specified as Amps Load
constant_current_B 0..1
Complex
constant current load on phase B, specified as Amps Load
constant_current_C 0..1
Complex
constant current load on phase C, specified as Amps Load
constant_current_A_real 0..1
Float
constant current load on phase A, real only, specified as Amps Load
constant_current_B_real 0..1
Float
constant current load on phase B, real only, specified as Amps Load
constant_current_C_real 0..1
Float
constant current load on phase C, real only, specified as Amps Load
constant_current_A_reac 0..1
Float
constant current load on phase A, imaginary only, specified as Amps Load
constant_current_B_reac 0..1
Float
constant current load on phase B, imaginary only, specified as Amps Load
constant_current_C_reac 0..1
Float
constant current load on phase C, imaginary only, specified as Amps Load
constant_impedance_A 0..1
Complex
constant impedance load on phase A, specified as Ohms Load
constant_impedance_B 0..1
Complex
constant impedance load on phase B, specified as Ohms Load
constant_impedance_C 0..1
Complex
constant impedance load on phase C, specified as Ohms Load
constant_impedance_A_real 0..1
Float
constant impedance load on phase A, real only, specified as Ohms Load
constant_impedance_B_real 0..1
Float
constant impedance load on phase B, real only, specified as Ohms Load
constant_impedance_C_real 0..1
Float
constant impedance load on phase C, real only, specified as Ohms Load
constant_impedance_A_reac 0..1
Float
constant impedance load on phase A, imaginary only, specified as Ohms Load
constant_impedance_B_reac 0..1
Float
constant impedance load on phase B, imaginary only, specified as Ohms Load
constant_impedance_C_reac 0..1
Float
constant impedance load on phase C, imaginary only, specified as Ohms Load
constant_power_AN 0..1
Complex
constant power wye-connected load on phase A, specified as VA Load
constant_power_BN 0..1
Complex
constant power wye-connected load on phase B, specified as VA Load
constant_power_CN 0..1
Complex
constant power wye-connected load on phase C, specified as VA Load
constant_power_AN_real 0..1
Float
constant power wye-connected load on phase A, real only, specified as W Load
constant_power_BN_real 0..1
Float
constant power wye-connected load on phase B, real only, specified as W Load
constant_power_CN_real 0..1
Float
constant power wye-connected load on phase C, real only, specified as W Load
constant_power_AN_reac 0..1
Float
constant power wye-connected load on phase A, imaginary only, specified as VA... Load
constant_power_BN_reac 0..1
Float
constant power wye-connected load on phase B, imaginary only, specified as VA... Load
constant_power_CN_reac 0..1
Float
constant power wye-connected load on phase C, imaginary only, specified as VA... Load
constant_current_AN 0..1
Complex
constant current wye-connected load on phase A, specified as Amps Load
constant_current_BN 0..1
Complex
constant current wye-connected load on phase B, specified as Amps Load
constant_current_CN 0..1
Complex
constant current wye-connected load on phase C, specified as Amps Load
constant_current_AN_real 0..1
Float
constant current wye-connected load on phase A, real only, specified as Amps Load
constant_current_BN_real 0..1
Float
constant current wye-connected load on phase B, real only, specified as Amps Load
constant_current_CN_real 0..1
Float
constant current wye-connected load on phase C, real only, specified as Amps Load
constant_current_AN_reac 0..1
Float
constant current wye-connected load on phase A, imaginary only, specified as ... Load
constant_current_BN_reac 0..1
Float
constant current wye-connected load on phase B, imaginary only, specified as ... Load
constant_current_CN_reac 0..1
Float
constant current wye-connected load on phase C, imaginary only, specified as ... Load
constant_impedance_AN 0..1
Complex
constant impedance wye-connected load on phase A, specified as Ohms Load
constant_impedance_BN 0..1
Complex
constant impedance wye-connected load on phase B, specified as Ohms Load
constant_impedance_CN 0..1
Complex
constant impedance wye-connected load on phase C, specified as Ohms Load
constant_impedance_AN_real 0..1
Float
constant impedance wye-connected load on phase A, real only, specified as Ohm... Load
constant_impedance_BN_real 0..1
Float
constant impedance wye-connected load on phase B, real only, specified as Ohm... Load
constant_impedance_CN_real 0..1
Float
constant impedance wye-connected load on phase C, real only, specified as Ohm... Load
constant_impedance_AN_reac 0..1
Float
constant impedance wye-connected load on phase A, imaginary only, specified a... Load
constant_impedance_BN_reac 0..1
Float
constant impedance wye-connected load on phase B, imaginary only, specified a... Load
constant_impedance_CN_reac 0..1
Float
constant impedance wye-connected load on phase C, imaginary only, specified a... Load
constant_power_AB 0..1
Complex
constant power delta-connected load on phase A, specified as VA Load
constant_power_BC 0..1
Complex
constant power delta-connected load on phase B, specified as VA Load
constant_power_CA 0..1
Complex
constant power delta-connected load on phase C, specified as VA Load
constant_power_AB_real 0..1
Float
constant power delta-connected load on phase A, real only, specified as W Load
constant_power_BC_real 0..1
Float
constant power delta-connected load on phase B, real only, specified as W Load
constant_power_CA_real 0..1
Float
constant power delta-connected load on phase C, real only, specified as W Load
constant_power_AB_reac 0..1
Float
constant power delta-connected load on phase A, imaginary only, specified as ... Load
constant_power_BC_reac 0..1
Float
constant power delta-connected load on phase B, imaginary only, specified as ... Load
constant_power_CA_reac 0..1
Float
constant power delta-connected load on phase C, imaginary only, specified as ... Load
constant_current_AB 0..1
Complex
constant current delta-connected load on phase A, specified as Amps Load
constant_current_BC 0..1
Complex
constant current delta-connected load on phase B, specified as Amps Load
constant_current_CA 0..1
Complex
constant current delta-connected load on phase C, specified as Amps Load
constant_current_AB_real 0..1
Float
constant current delta-connected load on phase A, real only, specified as Amp... Load
constant_current_BC_real 0..1
Float
constant current delta-connected load on phase B, real only, specified as Amp... Load
constant_current_CA_real 0..1
Float
constant current delta-connected load on phase C, real only, specified as Amp... Load
constant_current_AB_reac 0..1
Float
constant current delta-connected load on phase A, imaginary only, specified a... Load
constant_current_BC_reac 0..1
Float
constant current delta-connected load on phase B, imaginary only, specified a... Load
constant_current_CA_reac 0..1
Float
constant current delta-connected load on phase C, imaginary only, specified a... Load
constant_impedance_AB 0..1
Complex
constant impedance delta-connected load on phase A, specified as Ohms Load
constant_impedance_BC 0..1
Complex
constant impedance delta-connected load on phase B, specified as Ohms Load
constant_impedance_CA 0..1
Complex
constant impedance delta-connected load on phase C, specified as Ohms Load
constant_impedance_AB_real 0..1
Float
constant impedance delta-connected load on phase A, real only, specified as O... Load
constant_impedance_BC_real 0..1
Float
constant impedance delta-connected load on phase B, real only, specified as O... Load
constant_impedance_CA_real 0..1
Float
constant impedance delta-connected load on phase C, real only, specified as O... Load
constant_impedance_AB_reac 0..1
Float
constant impedance delta-connected load on phase A, imaginary only, specified... Load
constant_impedance_BC_reac 0..1
Float
constant impedance delta-connected load on phase B, imaginary only, specified... Load
constant_impedance_CA_reac 0..1
Float
constant impedance delta-connected load on phase C, imaginary only, specified... Load
measured_voltage_A 0..1
Complex
current measured voltage on phase A Load
measured_voltage_B 0..1
Complex
current measured voltage on phase B Load
measured_voltage_C 0..1
Complex
current measured voltage on phase C Load
measured_voltage_AB 0..1
Complex
current measured voltage on phases AB Load
measured_voltage_BC 0..1
Complex
current measured voltage on phases BC Load
measured_voltage_CA 0..1
Complex
current measured voltage on phases CA Load
phase_loss_protection 0..1
Boolean
Trip all three phases of the load if a fault occurs Load
measured_power_A 0..1
Complex
current measured power on phase A Load
measured_power_B 0..1
Complex
current measured power on phase B Load
measured_power_C 0..1
Complex
current measured power on phase C Load
measured_power 0..1
Complex
current total power Load
base_power_A 0..1
Float
in similar format as ZIPload, this represents the nominal power on phase A be... Load
base_power_B 0..1
Float
in similar format as ZIPload, this represents the nominal power on phase B be... Load
base_power_C 0..1
Float
in similar format as ZIPload, this represents the nominal power on phase C be... Load
power_pf_A 0..1
Float
in similar format as ZIPload, this is the power factor of the phase A constan... Load
current_pf_A 0..1
Float
in similar format as ZIPload, this is the power factor of the phase A constan... Load
impedance_pf_A 0..1
Float
in similar format as ZIPload, this is the power factor of the phase A constan... Load
power_pf_B 0..1
Float
in similar format as ZIPload, this is the power factor of the phase B constan... Load
current_pf_B 0..1
Float
in similar format as ZIPload, this is the power factor of the phase B constan... Load
impedance_pf_B 0..1
Float
in similar format as ZIPload, this is the power factor of the phase B constan... Load
power_pf_C 0..1
Float
in similar format as ZIPload, this is the power factor of the phase C constan... Load
current_pf_C 0..1
Float
in similar format as ZIPload, this is the power factor of the phase C constan... Load
impedance_pf_C 0..1
Float
in similar format as ZIPload, this is the power factor of the phase C constan... Load
power_fraction_A 0..1
Float
this is the constant power fraction of base power on phase A Load
current_fraction_A 0..1
Float
this is the constant current fraction of base power on phase A Load
impedance_fraction_A 0..1
Float
this is the constant impedance fraction of base power on phase A Load
power_fraction_B 0..1
Float
this is the constant power fraction of base power on phase B Load
current_fraction_B 0..1
Float
this is the constant current fraction of base power on phase B Load
impedance_fraction_B 0..1
Float
this is the constant impedance fraction of base power on phase B Load
power_fraction_C 0..1
Float
this is the constant power fraction of base power on phase C Load
current_fraction_C 0..1
Float
this is the constant current fraction of base power on phase C Load
impedance_fraction_C 0..1
Float
this is the constant impedance fraction of base power on phase C Load
inrush_integration_method_capacitance 0..1
String
Selected integration method to use for capacitive elements of the load Load
inrush_integration_method_inductance 0..1
String
Selected integration method to use for inductive elements of the load Load
bustype 0..1
String
defines whether the node is a PQ, PV, or SWING node Node
busflags 0..1
String
flag indicates node has a source for voltage, i Node
reference_bus 0..1
String
reference bus from which frequency is defined Node
maximum_voltage_error 0..1
Float
convergence voltage limit or convergence criteria Node
voltage_A 0..1
Complex
bus voltage, Phase A to ground Node
voltage_B 0..1
Complex
bus voltage, Phase B to ground Node
voltage_C 0..1
Complex
bus voltage, Phase C to ground Node
voltage_AB 0..1
Complex
line voltages, Phase AB Node
voltage_BC 0..1
Complex
line voltages, Phase BC Node
voltage_CA 0..1
Complex
line voltages, Phase CA Node
current_A 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
current_B 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
current_C 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
power_A 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
power_B 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
power_C 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
shunt_A 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
shunt_B 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
shunt_C 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
prerotated_current_A 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
prerotated_current_B 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
prerotated_current_C 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
deltamode_generator_current_A 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_generator_current_B 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_generator_current_C 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_PGenTotal 0..1
Complex
deltamode-functionality - power value for a diesel generator -- accumulator o... Node
deltamode_full_Y_matrix 0..1
String
deltamode-functionality full_Y matrix exposes so generator objects can intera... Node
deltamode_full_Y_all_matrix 0..1
String
deltamode-functionality full_Y_all matrix exposes so generator objects can in... Node
NR_powerflow_parent 0..1
String
NR powerflow - actual powerflow parent - used by generators accessing child o... Node
current_inj_A 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_inj_B 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_inj_C 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_AB 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_BC 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_CA 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_AN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
current_BN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
current_CN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
power_AB 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_BC 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_CA 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_AN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
power_BN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
power_CN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
shunt_AB 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_BC 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_CA 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_AN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
shunt_BN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
shunt_CN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
residential_nominal_current_A 0..1
Complex
posted current on phase A from a residential object, if attached Node
residential_nominal_current_B 0..1
Complex
posted current on phase B from a residential object, if attached Node
residential_nominal_current_C 0..1
Complex
posted current on phase C from a residential object, if attached Node
residential_nominal_current_A_real 0..1
Float
posted current on phase A, real, from a residential object, if attached Node
residential_nominal_current_A_imag 0..1
Float
posted current on phase A, imag, from a residential object, if attached Node
residential_nominal_current_B_real 0..1
Float
posted current on phase B, real, from a residential object, if attached Node
residential_nominal_current_B_imag 0..1
Float
posted current on phase B, imag, from a residential object, if attached Node
residential_nominal_current_C_real 0..1
Float
posted current on phase C, real, from a residential object, if attached Node
residential_nominal_current_C_imag 0..1
Float
posted current on phase C, imag, from a residential object, if attached Node
house_present 0..1
Boolean
boolean for detecting whether a house is attached, not an input Node
mean_repair_time 0..1
Float
Time after a fault clears for the object to be back in service Node
frequency_measure_type 0..1
String
PLL frequency measurement Node
sfm_Tf 0..1
Float
Transducer time constant for simplified frequency measurement (seconds) Node
pll_Kp 0..1
Float
Proportional gain of PLL frequency measurement Node
pll_Ki 0..1
Float
Integration gain of PLL frequency measurement Node
measured_angle_A 0..1
Float
bus angle measurement, phase A Node
measured_frequency_A 0..1
Float
frequency measurement, phase A Node
measured_angle_B 0..1
Float
bus angle measurement, phase B Node
measured_frequency_B 0..1
Float
frequency measurement, phase B Node
measured_angle_C 0..1
Float
bus angle measurement, phase C Node
measured_frequency_C 0..1
Float
frequency measurement, phase C Node
measured_frequency 0..1
Float
frequency measurement - average of present phases Node
service_status 0..1
String
In and out of service flag Node
service_status_double 0..1
Float
In and out of service flag - type double - will indiscriminately override ser... Node
previous_uptime 0..1
Float
Previous time between disconnects of node in minutes Node
current_uptime 0..1
Float
Current time since last disconnect of node in minutes Node
Norton_dynamic 0..1
Boolean
Flag to indicate a Norton-equivalent connection -- used for generators and de... Node
Norton_dynamic_child 0..1
Boolean
Flag to indicate a Norton-equivalent connection is made by a childed node obj... Node
generator_dynamic 0..1
Boolean
Flag to indicate a voltage-sourcing or swing-type generator is present -- use... Node
reset_disabled_island_state 0..1
Boolean
Deltamode/multi-island flag -- used to reset disabled status (and reform an i... Node
GFA_enable 0..1
Boolean
Disable/Enable Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_low_trip 0..1
Float
Low frequency trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_high_trip 0..1
Float
High frequency trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_volt_low_trip 0..1
Float
Low voltage trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_volt_high_trip 0..1
Float
High voltage trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_reconnect_time 0..1
Float
Reconnect time for Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_disconnect_time 0..1
Float
Frequency violation disconnect time for Grid Friendly Appliance(TM)-type func... Node
GFA_volt_disconnect_time 0..1
Float
Voltage violation disconnect time for Grid Friendly Appliance(TM)-type functi... Node
GFA_status 0..1
Boolean
Grid Friendly Appliance(TM)-type functionality - whether it is in service (no... Node
GFA_trip_method 0..1
String
GFA trip for over-voltage Node
topological_parent 0..1
String
topological parent as per GLM configuration Node
behaving_as_swing 0..1
Boolean
Indicator flag for if a bus is behaving as a reference voltage source - valid... Node
phases 0..1
String
PowerflowObject
nominal_voltage 0..1
Float
PowerflowObject
inrush_integration_method 0..1
String
Integration method for in-rush PowerflowObject
condition 0..1
String
PowerflowObject
solution 0..1
String
PowerflowObject
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • CIMHub does not convert this class. The importer reads no property of it and lists it, with its count, on the master's not-mapped comment; the exporter writes none.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:Pqload
native glm:Pqload

LinkML Source

Direct

name: pqload
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file pqload.cpp

  @addtogroup pqload

  @ingroup node

  Load objects represent static loads and export both voltages and

  current.

  @{


  Inherits from: load


  Type: Instance (network topology element)'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
  it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: load
attributes:
  weather:
    name: weather
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: weather
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    - solar
    - house
    range: string
    required: false
  T_nominal:
    name: T_nominal
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: T_nominal[degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: degF
  Zp_T:
    name: Zp_T
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_T[ohm/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm/degF
  Zp_H:
    name: Zp_H
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_H[ohm/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm/%
  Zp_S:
    name: Zp_S
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_S[ohm*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm*h/Btu
  Zp_W:
    name: Zp_W
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_W[ohm/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm/mph
  Zp_R:
    name: Zp_R
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_R[ohm*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm*h/in
  Zp:
    name: Zp
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp[ohm]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm
  Zq_T:
    name: Zq_T
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_T[F/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F/degF
  Zq_H:
    name: Zq_H
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_H[F/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F/%
  Zq_S:
    name: Zq_S
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_S[F*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F*h/Btu
  Zq_W:
    name: Zq_W
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_W[F/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F/mph
  Zq_R:
    name: Zq_R
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_R[F*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F*h/in
  Zq:
    name: Zq
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq[F]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F
  Im_T:
    name: Im_T
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_T[A/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A/degF
  Im_H:
    name: Im_H
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_H[A/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A/%
  Im_S:
    name: Im_S
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_S[A*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A*h/Btu
  Im_W:
    name: Im_W
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_W[A/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A/mph
  Im_R:
    name: Im_R
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_R[A*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A*h/in
  Im:
    name: Im
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A
  Ia_T:
    name: Ia_T
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_T[deg/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg/degF
  Ia_H:
    name: Ia_H
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_H[deg/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg/%
  Ia_S:
    name: Ia_S
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_S[deg*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg*h/Btu
  Ia_W:
    name: Ia_W
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_W[deg/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg/mph
  Ia_R:
    name: Ia_R
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_R[deg*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg*h/in
  Ia:
    name: Ia
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia[deg]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg
  Pp_T:
    name: Pp_T
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_T[W/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W/degF
  Pp_H:
    name: Pp_H
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_H[W/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W/%
  Pp_S:
    name: Pp_S
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_S[W*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W*h/Btu
  Pp_W:
    name: Pp_W
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_W[W/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W/mph
  Pp_R:
    name: Pp_R
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_R[W*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W*h/in
  Pp:
    name: Pp
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp[W]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W
  Pq_T:
    name: Pq_T
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_T[VAr/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr/degF
  Pq_H:
    name: Pq_H
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_H[VAr/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr/%
  Pq_S:
    name: Pq_S
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_S[VAr*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr*h/Btu
  Pq_W:
    name: Pq_W
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_W[VAr/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr/mph
  Pq_R:
    name: Pq_R
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_R[VAr*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr*h/in
  Pq:
    name: Pq
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq[VAr]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr
  input_temp:
    name: input_temp
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_temp[degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: degF
  input_humid:
    name: input_humid
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_humid[%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: '%'
  input_solar:
    name: input_solar
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_solar[Btu/h]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: Btu/h
  input_wind:
    name: input_wind
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_wind[mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: mph
  input_rain:
    name: input_rain
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_rain[in/h]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: in/h
  output_imped_p:
    name: output_imped_p
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_imped_p[Ohm]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: Ohm
  output_imped_q:
    name: output_imped_q
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_imped_q[Ohm]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: Ohm
  output_current_m:
    name: output_current_m
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_current_m[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A
  output_current_a:
    name: output_current_a
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_current_a[deg]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg
  output_power_p:
    name: output_power_p
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_power_p[W]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W
  output_power_q:
    name: output_power_q
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_power_q[VAr]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr
  output_impedance:
    name: output_impedance
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: output_impedance[ohm]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    range: Complex
    required: false
    unit:
      ucum_code: ohm
  output_current:
    name: output_current
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: output_current[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    - energy_storage
    range: Complex
    required: false
    unit:
      ucum_code: A
  output_power:
    name: output_power
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: output_power[VA]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    domain_of:
    - pqload
    - energy_storage
    range: Complex
    required: false
    unit:
      ucum_code: VA

Induced

name: pqload
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file pqload.cpp

  @addtogroup pqload

  @ingroup node

  Load objects represent static loads and export both voltages and

  current.

  @{


  Inherits from: load


  Type: Instance (network topology element)'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
  it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: load
attributes:
  weather:
    name: weather
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: weather
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    - solar
    - house
    range: string
    required: false
  T_nominal:
    name: T_nominal
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: T_nominal[degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: degF
  Zp_T:
    name: Zp_T
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_T[ohm/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm/degF
  Zp_H:
    name: Zp_H
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_H[ohm/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm/%
  Zp_S:
    name: Zp_S
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_S[ohm*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm*h/Btu
  Zp_W:
    name: Zp_W
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_W[ohm/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm/mph
  Zp_R:
    name: Zp_R
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp_R[ohm*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm*h/in
  Zp:
    name: Zp
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zp[ohm]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: ohm
  Zq_T:
    name: Zq_T
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_T[F/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F/degF
  Zq_H:
    name: Zq_H
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_H[F/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F/%
  Zq_S:
    name: Zq_S
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_S[F*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F*h/Btu
  Zq_W:
    name: Zq_W
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_W[F/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F/mph
  Zq_R:
    name: Zq_R
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq_R[F*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F*h/in
  Zq:
    name: Zq
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Zq[F]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: F
  Im_T:
    name: Im_T
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_T[A/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A/degF
  Im_H:
    name: Im_H
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_H[A/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A/%
  Im_S:
    name: Im_S
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_S[A*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A*h/Btu
  Im_W:
    name: Im_W
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_W[A/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A/mph
  Im_R:
    name: Im_R
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im_R[A*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A*h/in
  Im:
    name: Im
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Im[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A
  Ia_T:
    name: Ia_T
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_T[deg/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg/degF
  Ia_H:
    name: Ia_H
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_H[deg/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg/%
  Ia_S:
    name: Ia_S
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_S[deg*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg*h/Btu
  Ia_W:
    name: Ia_W
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_W[deg/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg/mph
  Ia_R:
    name: Ia_R
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia_R[deg*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg*h/in
  Ia:
    name: Ia
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ia[deg]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg
  Pp_T:
    name: Pp_T
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_T[W/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W/degF
  Pp_H:
    name: Pp_H
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_H[W/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W/%
  Pp_S:
    name: Pp_S
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_S[W*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W*h/Btu
  Pp_W:
    name: Pp_W
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_W[W/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W/mph
  Pp_R:
    name: Pp_R
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp_R[W*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W*h/in
  Pp:
    name: Pp
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pp[W]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W
  Pq_T:
    name: Pq_T
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_T[VAr/degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr/degF
  Pq_H:
    name: Pq_H
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_H[VAr/%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr/%
  Pq_S:
    name: Pq_S
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_S[VAr*h/Btu]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr*h/Btu
  Pq_W:
    name: Pq_W
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_W[VAr/mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr/mph
  Pq_R:
    name: Pq_R
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq_R[VAr*h/in]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr*h/in
  Pq:
    name: Pq
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pq[VAr]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr
  input_temp:
    name: input_temp
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_temp[degF]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: degF
  input_humid:
    name: input_humid
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_humid[%]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: '%'
  input_solar:
    name: input_solar
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_solar[Btu/h]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: Btu/h
  input_wind:
    name: input_wind
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_wind[mph]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: mph
  input_rain:
    name: input_rain
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: input_rain[in/h]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: in/h
  output_imped_p:
    name: output_imped_p
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_imped_p[Ohm]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: Ohm
  output_imped_q:
    name: output_imped_q
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_imped_q[Ohm]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: Ohm
  output_current_m:
    name: output_current_m
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_current_m[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: A
  output_current_a:
    name: output_current_a
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_current_a[deg]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: deg
  output_power_p:
    name: output_power_p
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_power_p[W]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: W
  output_power_q:
    name: output_power_q
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: output_power_q[VAr]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: float
    required: false
    unit:
      ucum_code: VAr
  output_impedance:
    name: output_impedance
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: output_impedance[ohm]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    range: Complex
    required: false
    unit:
      ucum_code: ohm
  output_current:
    name: output_current
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: output_current[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    - energy_storage
    range: Complex
    required: false
    unit:
      ucum_code: A
  output_power:
    name: output_power
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: output_power[VA]
    from_schema: https://gridlabd.org/schema/glm/powerflow/pqload
    rank: 1000
    owner: pqload
    domain_of:
    - pqload
    - energy_storage
    range: Complex
    required: false
    unit:
      ucum_code: VA
  load_class:
    name: load_class
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: load_class
    description: Flag to track load type, not currently used for anything except sorting
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - triplex_load
    range: string
    required: false
  load_priority:
    name: load_priority
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: load_priority
    description: Load classification based on priority
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - triplex_load
    range: string
    required: false
  constant_power_A:
    name: constant_power_A
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_A[VA]
    description: constant power load on phase A, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_B:
    name: constant_power_B
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_B[VA]
    description: constant power load on phase B, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_C:
    name: constant_power_C
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_C[VA]
    description: constant power load on phase C, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_A_real:
    name: constant_power_A_real
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_A_real[W]
    description: constant power load on phase A, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_B_real:
    name: constant_power_B_real
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_B_real[W]
    description: constant power load on phase B, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_C_real:
    name: constant_power_C_real
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_C_real[W]
    description: constant power load on phase C, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_A_reac:
    name: constant_power_A_reac
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_A_reac[VAr]
    description: constant power load on phase A, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_B_reac:
    name: constant_power_B_reac
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_B_reac[VAr]
    description: constant power load on phase B, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_C_reac:
    name: constant_power_C_reac
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_C_reac[VAr]
    description: constant power load on phase C, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_current_A:
    name: constant_current_A
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_A[A]
    description: constant current load on phase A, specified as Amps
    comments:
    - 'Import: raises when set, as every explicit constant_current, constant_impedance
      and connection form (AN, AB, _real, _reac). Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_B:
    name: constant_current_B
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_B[A]
    description: constant current load on phase B, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_C:
    name: constant_current_C
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_C[A]
    description: constant current load on phase C, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_A_real:
    name: constant_current_A_real
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_A_real[A]
    description: constant current load on phase A, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_B_real:
    name: constant_current_B_real
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_B_real[A]
    description: constant current load on phase B, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_C_real:
    name: constant_current_C_real
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_C_real[A]
    description: constant current load on phase C, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_A_reac:
    name: constant_current_A_reac
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_A_reac[A]
    description: constant current load on phase A, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_B_reac:
    name: constant_current_B_reac
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_B_reac[A]
    description: constant current load on phase B, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_C_reac:
    name: constant_current_C_reac
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_C_reac[A]
    description: constant current load on phase C, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_impedance_A:
    name: constant_impedance_A
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_A[Ohm]
    description: constant impedance load on phase A, specified as Ohms
    comments:
    - 'Import: raises when set (see constant_current_A). Export: not written; the
      base_power form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_B:
    name: constant_impedance_B
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_B[Ohm]
    description: constant impedance load on phase B, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_C:
    name: constant_impedance_C
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_C[Ohm]
    description: constant impedance load on phase C, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_A_real:
    name: constant_impedance_A_real
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_A_real[Ohm]
    description: constant impedance load on phase A, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_B_real:
    name: constant_impedance_B_real
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_B_real[Ohm]
    description: constant impedance load on phase B, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_C_real:
    name: constant_impedance_C_real
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_C_real[Ohm]
    description: constant impedance load on phase C, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_A_reac:
    name: constant_impedance_A_reac
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_A_reac[Ohm]
    description: constant impedance load on phase A, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_B_reac:
    name: constant_impedance_B_reac
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_B_reac[Ohm]
    description: constant impedance load on phase B, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_C_reac:
    name: constant_impedance_C_reac
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_C_reac[Ohm]
    description: constant impedance load on phase C, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_power_AN:
    name: constant_power_AN
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_AN[VA]
    description: constant power wye-connected load on phase A, specified as VA
    comments:
    - 'Import: raises when set (see constant_current_A). Export: not written; the
      base_power form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_BN:
    name: constant_power_BN
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_BN[VA]
    description: constant power wye-connected load on phase B, specified as VA
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_CN:
    name: constant_power_CN
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_CN[VA]
    description: constant power wye-connected load on phase C, specified as VA
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_AN_real:
    name: constant_power_AN_real
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_AN_real[W]
    description: constant power wye-connected load on phase A, real only, specified
      as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_BN_real:
    name: constant_power_BN_real
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_BN_real[W]
    description: constant power wye-connected load on phase B, real only, specified
      as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_CN_real:
    name: constant_power_CN_real
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_CN_real[W]
    description: constant power wye-connected load on phase C, real only, specified
      as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_AN_reac:
    name: constant_power_AN_reac
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_AN_reac[VAr]
    description: constant power wye-connected load on phase A, imaginary only, specified
      as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_BN_reac:
    name: constant_power_BN_reac
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_BN_reac[VAr]
    description: constant power wye-connected load on phase B, imaginary only, specified
      as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_CN_reac:
    name: constant_power_CN_reac
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_CN_reac[VAr]
    description: constant power wye-connected load on phase C, imaginary only, specified
      as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_current_AN:
    name: constant_current_AN
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_AN[A]
    description: constant current wye-connected load on phase A, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_BN:
    name: constant_current_BN
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_BN[A]
    description: constant current wye-connected load on phase B, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_CN:
    name: constant_current_CN
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_CN[A]
    description: constant current wye-connected load on phase C, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_AN_real:
    name: constant_current_AN_real
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_AN_real[A]
    description: constant current wye-connected load on phase A, real only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_BN_real:
    name: constant_current_BN_real
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_BN_real[A]
    description: constant current wye-connected load on phase B, real only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_CN_real:
    name: constant_current_CN_real
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_CN_real[A]
    description: constant current wye-connected load on phase C, real only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_AN_reac:
    name: constant_current_AN_reac
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_AN_reac[A]
    description: constant current wye-connected load on phase A, imaginary only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_BN_reac:
    name: constant_current_BN_reac
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_BN_reac[A]
    description: constant current wye-connected load on phase B, imaginary only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_CN_reac:
    name: constant_current_CN_reac
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_CN_reac[A]
    description: constant current wye-connected load on phase C, imaginary only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_impedance_AN:
    name: constant_impedance_AN
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_AN[Ohm]
    description: constant impedance wye-connected load on phase A, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_BN:
    name: constant_impedance_BN
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_BN[Ohm]
    description: constant impedance wye-connected load on phase B, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_CN:
    name: constant_impedance_CN
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_CN[Ohm]
    description: constant impedance wye-connected load on phase C, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_AN_real:
    name: constant_impedance_AN_real
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_AN_real[Ohm]
    description: constant impedance wye-connected load on phase A, real only, specified
      as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_BN_real:
    name: constant_impedance_BN_real
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_BN_real[Ohm]
    description: constant impedance wye-connected load on phase B, real only, specified
      as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_CN_real:
    name: constant_impedance_CN_real
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_CN_real[Ohm]
    description: constant impedance wye-connected load on phase C, real only, specified
      as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_AN_reac:
    name: constant_impedance_AN_reac
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_AN_reac[Ohm]
    description: constant impedance wye-connected load on phase A, imaginary only,
      specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_BN_reac:
    name: constant_impedance_BN_reac
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_BN_reac[Ohm]
    description: constant impedance wye-connected load on phase B, imaginary only,
      specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_CN_reac:
    name: constant_impedance_CN_reac
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_CN_reac[Ohm]
    description: constant impedance wye-connected load on phase C, imaginary only,
      specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_power_AB:
    name: constant_power_AB
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_AB[VA]
    description: constant power delta-connected load on phase A, specified as VA
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_BC:
    name: constant_power_BC
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_BC[VA]
    description: constant power delta-connected load on phase B, specified as VA
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_CA:
    name: constant_power_CA
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_CA[VA]
    description: constant power delta-connected load on phase C, specified as VA
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_AB_real:
    name: constant_power_AB_real
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_AB_real[W]
    description: constant power delta-connected load on phase A, real only, specified
      as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_BC_real:
    name: constant_power_BC_real
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_BC_real[W]
    description: constant power delta-connected load on phase B, real only, specified
      as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_CA_real:
    name: constant_power_CA_real
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_CA_real[W]
    description: constant power delta-connected load on phase C, real only, specified
      as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_AB_reac:
    name: constant_power_AB_reac
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_AB_reac[VAr]
    description: constant power delta-connected load on phase A, imaginary only, specified
      as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_BC_reac:
    name: constant_power_BC_reac
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_BC_reac[VAr]
    description: constant power delta-connected load on phase B, imaginary only, specified
      as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_CA_reac:
    name: constant_power_CA_reac
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_CA_reac[VAr]
    description: constant power delta-connected load on phase C, imaginary only, specified
      as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_current_AB:
    name: constant_current_AB
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_AB[A]
    description: constant current delta-connected load on phase A, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_BC:
    name: constant_current_BC
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_BC[A]
    description: constant current delta-connected load on phase B, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_CA:
    name: constant_current_CA
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_CA[A]
    description: constant current delta-connected load on phase C, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_AB_real:
    name: constant_current_AB_real
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_AB_real[A]
    description: constant current delta-connected load on phase A, real only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_BC_real:
    name: constant_current_BC_real
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_BC_real[A]
    description: constant current delta-connected load on phase B, real only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_CA_real:
    name: constant_current_CA_real
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_CA_real[A]
    description: constant current delta-connected load on phase C, real only, specified
      as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_AB_reac:
    name: constant_current_AB_reac
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_AB_reac[A]
    description: constant current delta-connected load on phase A, imaginary only,
      specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_BC_reac:
    name: constant_current_BC_reac
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_BC_reac[A]
    description: constant current delta-connected load on phase B, imaginary only,
      specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_CA_reac:
    name: constant_current_CA_reac
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_CA_reac[A]
    description: constant current delta-connected load on phase C, imaginary only,
      specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_impedance_AB:
    name: constant_impedance_AB
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_AB[Ohm]
    description: constant impedance delta-connected load on phase A, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_BC:
    name: constant_impedance_BC
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_BC[Ohm]
    description: constant impedance delta-connected load on phase B, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_CA:
    name: constant_impedance_CA
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_CA[Ohm]
    description: constant impedance delta-connected load on phase C, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_AB_real:
    name: constant_impedance_AB_real
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_AB_real[Ohm]
    description: constant impedance delta-connected load on phase A, real only, specified
      as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_BC_real:
    name: constant_impedance_BC_real
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_BC_real[Ohm]
    description: constant impedance delta-connected load on phase B, real only, specified
      as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_CA_real:
    name: constant_impedance_CA_real
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_CA_real[Ohm]
    description: constant impedance delta-connected load on phase C, real only, specified
      as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_AB_reac:
    name: constant_impedance_AB_reac
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_AB_reac[Ohm]
    description: constant impedance delta-connected load on phase A, imaginary only,
      specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_BC_reac:
    name: constant_impedance_BC_reac
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_BC_reac[Ohm]
    description: constant impedance delta-connected load on phase B, imaginary only,
      specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_CA_reac:
    name: constant_impedance_CA_reac
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_CA_reac[Ohm]
    description: constant impedance delta-connected load on phase C, imaginary only,
      specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  measured_voltage_A:
    name: measured_voltage_A
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_A[V]
    description: current measured voltage on phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_B:
    name: measured_voltage_B
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_B[V]
    description: current measured voltage on phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_C:
    name: measured_voltage_C
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_C[V]
    description: current measured voltage on phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_AB:
    name: measured_voltage_AB
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_AB[V]
    description: current measured voltage on phases AB
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_BC:
    name: measured_voltage_BC
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_BC[V]
    description: current measured voltage on phases BC
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_CA:
    name: measured_voltage_CA
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_CA[V]
    description: current measured voltage on phases CA
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  phase_loss_protection:
    name: phase_loss_protection
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: phase_loss_protection
    description: Trip all three phases of the load if a fault occurs
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: boolean
    required: false
  measured_power_A:
    name: measured_power_A
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_A[VA]
    description: current measured power on phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power_B:
    name: measured_power_B
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_B[VA]
    description: current measured power on phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power_C:
    name: measured_power_C
    annotations:
      order:
        tag: order
        value: 93
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_C[VA]
    description: current measured power on phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power:
    name: measured_power
    annotations:
      order:
        tag: order
        value: 94
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power[VA]
    description: current total power
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    rank: 1000
    owner: pqload
    domain_of:
    - load
    - meter
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  base_power_A:
    name: base_power_A
    annotations:
      order:
        tag: order
        value: 95
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_A[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase A before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VA
  base_power_B:
    name: base_power_B
    annotations:
      order:
        tag: order
        value: 96
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_B[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase B before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VA
  base_power_C:
    name: base_power_C
    annotations:
      order:
        tag: order
        value: 97
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_C[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase C before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: VA
  power_pf_A:
    name: power_pf_A
    annotations:
      order:
        tag: order
        value: 98
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_A[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      A constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_A:
    name: current_pf_A
    annotations:
      order:
        tag: order
        value: 99
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_A[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      A constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_A:
    name: impedance_pf_A
    annotations:
      order:
        tag: order
        value: 100
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_A[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      A constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_pf_B:
    name: power_pf_B
    annotations:
      order:
        tag: order
        value: 101
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_B[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      B constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_B:
    name: current_pf_B
    annotations:
      order:
        tag: order
        value: 102
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_B[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      B constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_B:
    name: impedance_pf_B
    annotations:
      order:
        tag: order
        value: 103
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_B[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      B constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_pf_C:
    name: power_pf_C
    annotations:
      order:
        tag: order
        value: 104
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_C[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      C constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_C:
    name: current_pf_C
    annotations:
      order:
        tag: order
        value: 105
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_C[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      C constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_C:
    name: impedance_pf_C
    annotations:
      order:
        tag: order
        value: 106
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_C[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      C constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_A:
    name: power_fraction_A
    annotations:
      order:
        tag: order
        value: 107
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_A[pu]
    description: this is the constant power fraction of base power on phase A
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_A:
    name: current_fraction_A
    annotations:
      order:
        tag: order
        value: 108
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_A[pu]
    description: this is the constant current fraction of base power on phase A
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_A:
    name: impedance_fraction_A
    annotations:
      order:
        tag: order
        value: 109
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_A[pu]
    description: this is the constant impedance fraction of base power on phase A
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_B:
    name: power_fraction_B
    annotations:
      order:
        tag: order
        value: 110
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_B[pu]
    description: this is the constant power fraction of base power on phase B
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_B:
    name: current_fraction_B
    annotations:
      order:
        tag: order
        value: 111
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_B[pu]
    description: this is the constant current fraction of base power on phase B
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_B:
    name: impedance_fraction_B
    annotations:
      order:
        tag: order
        value: 112
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_B[pu]
    description: this is the constant impedance fraction of base power on phase B
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_C:
    name: power_fraction_C
    annotations:
      order:
        tag: order
        value: 113
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_C[pu]
    description: this is the constant power fraction of base power on phase C
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_C:
    name: current_fraction_C
    annotations:
      order:
        tag: order
        value: 114
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_C[pu]
    description: this is the constant current fraction of base power on phase C
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_C:
    name: impedance_fraction_C
    annotations:
      order:
        tag: order
        value: 115
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_C[pu]
    description: this is the constant impedance fraction of base power on phase C
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    owner: pqload
    domain_of:
    - load
    range: float
    required: false
    unit:
      ucum_code: pu
  inrush_integration_method_capacitance:
    name: inrush_integration_method_capacitance
    annotations:
      order:
        tag: order
        value: 116
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method_capacitance
    description: Selected integration method to use for capacitive elements of the
      load
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    owner: pqload
    domain_of:
    - link
    - load
    range: string
    required: false
  inrush_integration_method_inductance:
    name: inrush_integration_method_inductance
    annotations:
      order:
        tag: order
        value: 117
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method_inductance
    description: Selected integration method to use for inductive elements of the
      load
    from_schema: https://gridlabd.org/schema/glm/powerflow/load
    owner: pqload
    domain_of:
    - link
    - load
    range: string
    required: false
  bustype:
    name: bustype
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: bustype
    description: defines whether the node is a PQ, PV, or SWING node
    comments:
    - 'Import: SWING makes an EnergySource; PQ, PV and SWING_PQ are a plain bus (SWING_PQ
      is a swing only when islanded). Export: SWING on the substation only.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    related_mappings:
    - cim:EnergySource
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  busflags:
    name: busflags
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: busflags
    description: flag indicates node has a source for voltage, i.e. connects to the
      swing node
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  reference_bus:
    name: reference_bus
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reference_bus
    description: reference bus from which frequency is defined
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  maximum_voltage_error:
    name: maximum_voltage_error
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_voltage_error[V]
    description: convergence voltage limit or convergence criteria
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: V
  voltage_A:
    name: voltage_A
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_A[V]
    description: bus voltage, Phase A to ground
    comments:
    - 'Import: on a SWING bus only: EnergySource.voltageMagnitude (line to line) and
      voltageAngle (deg) from |V| and arg(V); elsewhere the solver guess, not converted.
      Export: not written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    close_mappings:
    - cim:EnergySource.voltageMagnitude
    - cim:EnergySource.voltageAngle
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_B:
    name: voltage_B
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_B[V]
    description: bus voltage, Phase B to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_C:
    name: voltage_C
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_C[V]
    description: bus voltage, Phase C to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_AB:
    name: voltage_AB
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_AB[V]
    description: line voltages, Phase AB
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_BC:
    name: voltage_BC
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_BC[V]
    description: line voltages, Phase BC
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_CA:
    name: voltage_CA
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_CA[V]
    description: line voltages, Phase CA
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  current_A:
    name: current_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_A[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_B:
    name: current_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_B[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_C:
    name: current_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_C[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_A:
    name: power_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_A[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_B:
    name: power_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_B[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_C:
    name: power_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_C[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_A:
    name: shunt_A
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_A[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_B:
    name: shunt_B
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_B[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_C:
    name: shunt_C
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_C[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  prerotated_current_A:
    name: prerotated_current_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_A[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_B:
    name: prerotated_current_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_B[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_C:
    name: prerotated_current_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_C[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_A:
    name: deltamode_generator_current_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_A[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_B:
    name: deltamode_generator_current_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_B[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_C:
    name: deltamode_generator_current_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_C[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_PGenTotal:
    name: deltamode_PGenTotal
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_PGenTotal
    description: deltamode-functionality - power value for a diesel generator -- accumulator
      only, not an output or input
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: Complex
    required: false
  deltamode_full_Y_matrix:
    name: deltamode_full_Y_matrix
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_matrix
    description: deltamode-functionality full_Y matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  deltamode_full_Y_all_matrix:
    name: deltamode_full_Y_all_matrix
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_all_matrix
    description: deltamode-functionality full_Y_all matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  NR_powerflow_parent:
    name: NR_powerflow_parent
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: NR_powerflow_parent
    description: NR powerflow - actual powerflow parent - used by generators accessing
      child objects
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  current_inj_A:
    name: current_inj_A
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_A[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_inj_B:
    name: current_inj_B
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_B[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_inj_C:
    name: current_inj_C
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_C[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_AB:
    name: current_AB
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_AB[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_BC:
    name: current_BC
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_BC[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_CA:
    name: current_CA
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_CA[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_AN:
    name: current_AN
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_AN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_BN:
    name: current_BN
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_BN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_CN:
    name: current_CN
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_CN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_AB:
    name: power_AB
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_AB[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_BC:
    name: power_BC
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_BC[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_CA:
    name: power_CA
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_CA[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_AN:
    name: power_AN
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_AN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_BN:
    name: power_BN
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_BN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_CN:
    name: power_CN
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_CN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_AB:
    name: shunt_AB
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_AB[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_BC:
    name: shunt_BC
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_BC[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_CA:
    name: shunt_CA
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_CA[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_AN:
    name: shunt_AN
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_AN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_BN:
    name: shunt_BN
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_BN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_CN:
    name: shunt_CN
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_CN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  residential_nominal_current_A:
    name: residential_nominal_current_A
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_A[A]
    description: posted current on phase A from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B:
    name: residential_nominal_current_B
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_B[A]
    description: posted current on phase B from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C:
    name: residential_nominal_current_C
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_C[A]
    description: posted current on phase C from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_A_real:
    name: residential_nominal_current_A_real
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_A_real[A]
    description: posted current on phase A, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_A_imag:
    name: residential_nominal_current_A_imag
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_A_imag[A]
    description: posted current on phase A, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B_real:
    name: residential_nominal_current_B_real
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_B_real[A]
    description: posted current on phase B, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B_imag:
    name: residential_nominal_current_B_imag
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_B_imag[A]
    description: posted current on phase B, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C_real:
    name: residential_nominal_current_C_real
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_C_real[A]
    description: posted current on phase C, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C_imag:
    name: residential_nominal_current_C_imag
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_C_imag[A]
    description: posted current on phase C, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  house_present:
    name: house_present
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: house_present
    description: boolean for detecting whether a house is attached, not an input
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  mean_repair_time:
    name: mean_repair_time
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mean_repair_time[s]
    description: Time after a fault clears for the object to be back in service
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    owner: pqload
    domain_of:
    - link
    - node
    range: float
    required: false
    unit:
      ucum_code: s
  frequency_measure_type:
    name: frequency_measure_type
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: frequency_measure_type
    description: PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  sfm_Tf:
    name: sfm_Tf
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sfm_Tf[s]
    description: Transducer time constant for simplified frequency measurement (seconds)
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  pll_Kp:
    name: pll_Kp
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Kp[pu]
    description: Proportional gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  pll_Ki:
    name: pll_Ki
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Ki[pu]
    description: Integration gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  measured_angle_A:
    name: measured_angle_A
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_A[rad]
    description: bus angle measurement, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_A:
    name: measured_frequency_A
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_A[Hz]
    description: frequency measurement, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_B:
    name: measured_angle_B
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_B[rad]
    description: bus angle measurement, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_B:
    name: measured_frequency_B
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_B[Hz]
    description: frequency measurement, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_C:
    name: measured_angle_C
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_C[rad]
    description: bus angle measurement, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_C:
    name: measured_frequency_C
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_C[Hz]
    description: frequency measurement, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_frequency:
    name: measured_frequency
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency[Hz]
    description: frequency measurement - average of present phases
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  service_status:
    name: service_status
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: service_status
    description: In and out of service flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  service_status_double:
    name: service_status_double
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: service_status_double
    description: In and out of service flag - type double - will indiscriminately
      override service_status - useful for schedules
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
  previous_uptime:
    name: previous_uptime
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_uptime[min]
    description: Previous time between disconnects of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  current_uptime:
    name: current_uptime
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_uptime[min]
    description: Current time since last disconnect of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  Norton_dynamic:
    name: Norton_dynamic
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic
    description: Flag to indicate a Norton-equivalent connection -- used for generators
      and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  Norton_dynamic_child:
    name: Norton_dynamic_child
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic_child
    description: Flag to indicate a Norton-equivalent connection is made by a childed
      node object -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  generator_dynamic:
    name: generator_dynamic
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: generator_dynamic
    description: Flag to indicate a voltage-sourcing or swing-type generator is present
      -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  reset_disabled_island_state:
    name: reset_disabled_island_state
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: reset_disabled_island_state
    description: Deltamode/multi-island flag -- used to reset disabled status (and
      reform an island)
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_enable:
    name: GFA_enable
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_enable
    description: Disable/Enable Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_freq_low_trip:
    name: GFA_freq_low_trip
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_low_trip[Hz]
    description: Low frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_freq_high_trip:
    name: GFA_freq_high_trip
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_high_trip[Hz]
    description: High frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_volt_low_trip:
    name: GFA_volt_low_trip
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_low_trip[pu]
    description: Low voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_volt_high_trip:
    name: GFA_volt_high_trip
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_high_trip[pu]
    description: High voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_reconnect_time:
    name: GFA_reconnect_time
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_reconnect_time[s]
    description: Reconnect time for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_freq_disconnect_time:
    name: GFA_freq_disconnect_time
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_disconnect_time[s]
    description: Frequency violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_volt_disconnect_time:
    name: GFA_volt_disconnect_time
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_disconnect_time[s]
    description: Voltage violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_status:
    name: GFA_status
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_status
    description: Grid Friendly Appliance(TM)-type functionality - whether it is in
      service (not tripped) or not
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_trip_method:
    name: GFA_trip_method
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: GFA_trip_method
    description: GFA trip for over-voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  topological_parent:
    name: topological_parent
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: topological_parent
    description: topological parent as per GLM configuration
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  behaving_as_swing:
    name: behaving_as_swing
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: behaving_as_swing
    description: Indicator flag for if a bus is behaving as a reference voltage source
      - valid for a SWING or SWING_PQ
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: pqload
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    comments:
    - 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
      Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
      Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
      when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
      bus); a switch or reactor side 1''s A, B, C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    related_mappings:
    - cim:Terminal.phases
    rank: 1000
    owner: pqload
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  nominal_voltage:
    name: nominal_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_voltage[V]
    comments:
    - 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
      over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
      (V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
      LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
      / sqrt 3.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    close_mappings:
    - cim:BaseVoltage.nominalVoltage
    - cim:EnergySource.nominalVoltage
    rank: 1000
    owner: pqload
    domain_of:
    - powerflow_object
    - battery
    - waterheater
    range: float
    required: false
    unit:
      ucum_code: V
  inrush_integration_method:
    name: inrush_integration_method
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method
    description: Integration method for in-rush
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: pqload
    domain_of:
    - powerflow_object
    range: string
    required: false
  condition:
    name: condition
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: condition
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: pqload
    domain_of:
    - powerflow_object
    range: string
    required: false
  solution:
    name: solution
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: solution
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: pqload
    domain_of:
    - powerflow_object
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: pqload
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: pqload
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: pqload
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: pqload
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: pqload
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: pqload
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: pqload
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: pqload
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: pqload
    domain_of:
    - glm_object
    range: string