Class: WindturbDg¶
Copyright (C) 2008 Battelle Memorial Institute
@file windturb_dg.cpp
@defgroup windturb_dg Wind Turbine gensets
@ingroup generators
__
Inherits from: gld_object
__
Type: Instance (network topology element)
__
Note: Inherits from gld_object (not in generators module)
URI: glm:WindturbDg
classDiagram
class WindturbDg
click WindturbDg href "../WindturbDg/"
GlmObject <|-- WindturbDg
click GlmObject href "../GlmObject/"
WindturbDg : air_density
WindturbDg : blade_diam
WindturbDg : blade_diameter
WindturbDg : Cp
WindturbDg : Cp_max
WindturbDg : Cp_rated
WindturbDg : current_12
WindturbDg --> "0..1" Complex : current_12
click Complex href "../Complex/"
WindturbDg : current_A
WindturbDg --> "0..1" Complex : current_A
click Complex href "../Complex/"
WindturbDg : current_B
WindturbDg --> "0..1" Complex : current_B
click Complex href "../Complex/"
WindturbDg : current_C
WindturbDg --> "0..1" Complex : current_C
click Complex href "../Complex/"
WindturbDg : cut_in_ws
WindturbDg : cut_out_ws
WindturbDg : EfA
WindturbDg --> "0..1" Complex : EfA
click Complex href "../Complex/"
WindturbDg : EfB
WindturbDg --> "0..1" Complex : EfB
click Complex href "../Complex/"
WindturbDg : EfC
WindturbDg --> "0..1" Complex : EfC
click Complex href "../Complex/"
WindturbDg : flags
WindturbDg : Gen_mode
WindturbDg : Gen_status
WindturbDg : Gen_type
WindturbDg --> "0..1" GenType : Gen_type
click GenType href "../GenType/"
WindturbDg : GenElecEff
WindturbDg : generator_efficiency
WindturbDg : groupid
WindturbDg : Iapu
WindturbDg --> "0..1" Complex : Iapu
click Complex href "../Complex/"
WindturbDg : Ibpu
WindturbDg --> "0..1" Complex : Ibpu
click Complex href "../Complex/"
WindturbDg : Icpu
WindturbDg --> "0..1" Complex : Icpu
click Complex href "../Complex/"
WindturbDg : in_svc
WindturbDg : internal_model_current_convergence
WindturbDg : Irotor_A
WindturbDg --> "0..1" Complex : Irotor_A
click Complex href "../Complex/"
WindturbDg : Irotor_B
WindturbDg --> "0..1" Complex : Irotor_B
click Complex href "../Complex/"
WindturbDg : Irotor_C
WindturbDg --> "0..1" Complex : Irotor_C
click Complex href "../Complex/"
WindturbDg : latitude
WindturbDg : longitude
WindturbDg : Max_Ef
WindturbDg : Max_Vrotor
WindturbDg : Min_Ef
WindturbDg : Min_Vrotor
WindturbDg : name
WindturbDg : NR_first_run
WindturbDg : out_svc
WindturbDg : P_converted
WindturbDg : parent
WindturbDg : Pconv
WindturbDg : pf
WindturbDg : phases
WindturbDg : power_12
WindturbDg --> "0..1" Complex : power_12
click Complex href "../Complex/"
WindturbDg : power_A
WindturbDg --> "0..1" Complex : power_A
click Complex href "../Complex/"
WindturbDg : power_B
WindturbDg --> "0..1" Complex : power_B
click Complex href "../Complex/"
WindturbDg : power_C
WindturbDg --> "0..1" Complex : power_C
click Complex href "../Complex/"
WindturbDg : power_curve_csv
WindturbDg : power_curve_pu
WindturbDg : power_factor
WindturbDg : prev_current12
WindturbDg --> "0..1" Complex : prev_current12
click Complex href "../Complex/"
WindturbDg : prev_current_A
WindturbDg --> "0..1" Complex : prev_current_A
click Complex href "../Complex/"
WindturbDg : prev_current_B
WindturbDg --> "0..1" Complex : prev_current_B
click Complex href "../Complex/"
WindturbDg : prev_current_C
WindturbDg --> "0..1" Complex : prev_current_C
click Complex href "../Complex/"
WindturbDg : R_core
WindturbDg : R_rotor
WindturbDg : R_stator
WindturbDg : rank
WindturbDg : Rated_V
WindturbDg : Rated_VA
WindturbDg : Rg
WindturbDg : roughness_length_factor
WindturbDg : Rs
WindturbDg : total_reactive_power
WindturbDg : total_real_power
WindturbDg : TotalReacPow
WindturbDg : TotalRealPow
WindturbDg : turbine_height
WindturbDg : Turbine_implementation
WindturbDg : Turbine_Model
WindturbDg : value_Circuit_V_A
WindturbDg --> "0..1" Complex : value_Circuit_V_A
click Complex href "../Complex/"
WindturbDg : value_Circuit_V_B
WindturbDg --> "0..1" Complex : value_Circuit_V_B
click Complex href "../Complex/"
WindturbDg : value_Circuit_V_C
WindturbDg --> "0..1" Complex : value_Circuit_V_C
click Complex href "../Complex/"
WindturbDg : value_Line12
WindturbDg --> "0..1" Complex : value_Line12
click Complex href "../Complex/"
WindturbDg : value_Line_I_A
WindturbDg --> "0..1" Complex : value_Line_I_A
click Complex href "../Complex/"
WindturbDg : value_Line_I_B
WindturbDg --> "0..1" Complex : value_Line_I_B
click Complex href "../Complex/"
WindturbDg : value_Line_I_C
WindturbDg --> "0..1" Complex : value_Line_I_C
click Complex href "../Complex/"
WindturbDg : Vapu
WindturbDg --> "0..1" Complex : Vapu
click Complex href "../Complex/"
WindturbDg : Vbpu
WindturbDg --> "0..1" Complex : Vbpu
click Complex href "../Complex/"
WindturbDg : Vcpu
WindturbDg --> "0..1" Complex : Vcpu
click Complex href "../Complex/"
WindturbDg : voltage_12
WindturbDg --> "0..1" Complex : voltage_12
click Complex href "../Complex/"
WindturbDg : voltage_1N
WindturbDg --> "0..1" Complex : voltage_1N
click Complex href "../Complex/"
WindturbDg : voltage_2N
WindturbDg --> "0..1" Complex : voltage_2N
click Complex href "../Complex/"
WindturbDg : voltage_A
WindturbDg --> "0..1" Complex : voltage_A
click Complex href "../Complex/"
WindturbDg : voltage_B
WindturbDg --> "0..1" Complex : voltage_B
click Complex href "../Complex/"
WindturbDg : voltage_C
WindturbDg --> "0..1" Complex : voltage_C
click Complex href "../Complex/"
WindturbDg : Vrotor_A
WindturbDg --> "0..1" Complex : Vrotor_A
click Complex href "../Complex/"
WindturbDg : Vrotor_B
WindturbDg --> "0..1" Complex : Vrotor_B
click Complex href "../Complex/"
WindturbDg : Vrotor_C
WindturbDg --> "0..1" Complex : Vrotor_C
click Complex href "../Complex/"
WindturbDg : Wind_Speed
WindturbDg : wind_speed
WindturbDg : wind_speed_adjusted
WindturbDg : wind_speed_hub_ht
WindturbDg : Wind_speed_source
WindturbDg : ws_maxcp
WindturbDg : ws_rated
WindturbDg : WSadj
WindturbDg : X_magnetic
WindturbDg : X_rotor
WindturbDg : X_stator
WindturbDg : Xg
WindturbDg : Xs
Inheritance¶
- GlmObject
- WindturbDg
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| Gen_status | 0..1 String |
COP: Generator is currently available to supply power | direct |
| Gen_type | 0..1 GenType |
COP: Standard synchronous generator; is also used to 'fake' a doubly-fed indu... | direct |
| Gen_mode | 0..1 String |
COP: Maintains the real and reactive output at the terminals - currently unsu... | direct |
| Turbine_Model | 0..1 String |
Generic model for a 1 | direct |
| Turbine_implementation | 0..1 String |
Wind turbine implementation based on Generic Power Curve | direct |
| Wind_speed_source | 0..1 String |
The climate data specifying the wind speed | direct |
| turbine_height | 0..1 Float |
Describes the height of the wind turbine hub above the ground | direct |
| roughness_length_factor | 0..1 Float |
European Wind Atlas unitless correction factor for adjusting wind speed at va... | direct |
| blade_diam | 0..1 Float |
COP: Diameter of blades | direct |
| blade_diameter | 0..1 Float |
COP: Diameter of blades | direct |
| cut_in_ws | 0..1 Float |
COP: Minimum wind speed for generator operation | direct |
| cut_out_ws | 0..1 Float |
COP: Maximum wind speed for generator operation | direct |
| ws_rated | 0..1 Float |
COP: Rated wind speed for generator operation | direct |
| ws_maxcp | 0..1 Float |
COP: Wind speed at which generator reaches maximum Cp | direct |
| Cp_max | 0..1 Float |
COP: Maximum coefficient of performance | direct |
| Cp_rated | 0..1 Float |
COP: Rated coefficient of performance | direct |
| Cp | 0..1 Float |
COP: Calculated coefficient of performance | direct |
| Rated_VA | 0..1 Float |
Rated generator power output | direct |
| Rated_V | 0..1 Float |
COP: Rated generator terminal voltage | direct |
| Pconv | 0..1 Float |
COP: Amount of electrical power converted from mechanical power delivered | direct |
| P_converted | 0..1 Float |
COP: Amount of electrical power converted from mechanical power delivered | direct |
| GenElecEff | 0..1 Float |
COP: Calculated generator electrical efficiency | direct |
| generator_efficiency | 0..1 Float |
COP: Calculated generator electrical efficiency | direct |
| TotalRealPow | 0..1 Float |
Total real power output | direct |
| total_real_power | 0..1 Float |
Total real power output | direct |
| TotalReacPow | 0..1 Float |
Total reactive power output | direct |
| total_reactive_power | 0..1 Float |
Total reactive power output | direct |
| power_A | 0..1 Complex |
Total complex power injected on phase A | direct |
| power_B | 0..1 Complex |
Total complex power injected on phase B | direct |
| power_C | 0..1 Complex |
Total complex power injected on phase C | direct |
| power_12 | 0..1 Complex |
Triplex mode - Total complex power on line 1 and 2 | direct |
| WSadj | 0..1 Float |
Speed of wind at hub height | direct |
| wind_speed_adjusted | 0..1 Float |
Speed of wind at hub height | direct |
| Wind_Speed | 0..1 Float |
Wind speed at 5-15m level (typical measurement height) | direct |
| wind_speed | 0..1 Float |
Wind speed at 5-15m level (typical measurement height) | direct |
| air_density | 0..1 Float |
COP: Estimated air density | direct |
| wind_speed_hub_ht | 0..1 Float |
Wind speed at hub height | direct |
| R_stator | 0..1 Float |
COP: Induction generator primary stator resistance in p | direct |
| X_stator | 0..1 Float |
COP: Induction generator primary stator reactance in p | direct |
| R_rotor | 0..1 Float |
COP: Induction generator primary rotor resistance in p | direct |
| X_rotor | 0..1 Float |
COP: Induction generator primary rotor reactance in p | direct |
| R_core | 0..1 Float |
COP: Induction generator primary core resistance in p | direct |
| X_magnetic | 0..1 Float |
COP: Induction generator primary core reactance in p | direct |
| Max_Vrotor | 0..1 Float |
COP: Induction generator maximum induced rotor voltage in p | direct |
| Min_Vrotor | 0..1 Float |
COP: Induction generator minimum induced rotor voltage in p | direct |
| Rs | 0..1 Float |
COP: Synchronous generator primary stator resistance in p | direct |
| Xs | 0..1 Float |
COP: Synchronous generator primary stator reactance in p | direct |
| Rg | 0..1 Float |
COP: Synchronous generator grounding resistance in p | direct |
| Xg | 0..1 Float |
COP: Synchronous generator grounding reactance in p | direct |
| Max_Ef | 0..1 Float |
COP: Synchronous generator maximum induced rotor voltage in p | direct |
| Min_Ef | 0..1 Float |
COP: Synchronous generator minimum induced rotor voltage in p | direct |
| pf | 0..1 Float |
COP: Desired power factor in CONSTANTP mode (can be modified over time) | direct |
| power_factor | 0..1 Float |
COP: Desired power factor in CONSTANTP mode (can be modified over time) | direct |
| power_curve_csv | 0..1 String |
Name of | direct |
| power_curve_pu | 0..1 Boolean |
Flag when set indicates that user provided power curve has power values in p | direct |
| voltage_A | 0..1 Complex |
Terminal voltage on phase A | direct |
| voltage_B | 0..1 Complex |
Terminal voltage on phase B | direct |
| voltage_C | 0..1 Complex |
Terminal voltage on phase C | direct |
| voltage_12 | 0..1 Complex |
Triplex mode - Voltage between line 1 and line 2 | direct |
| voltage_1N | 0..1 Complex |
Triplex mode - Voltage between line 1 and the neutral N | direct |
| voltage_2N | 0..1 Complex |
Triplex mode - Voltage between line 2 and the neutral N | direct |
| current_A | 0..1 Complex |
Calculated terminal current on phase A | direct |
| current_B | 0..1 Complex |
Calculated terminal current on phase B | direct |
| current_C | 0..1 Complex |
Calculated terminal current on phase C | direct |
| current_12 | 0..1 Complex |
Triplex mode - Calculated line current 12 | direct |
| EfA | 0..1 Complex |
COP: Synchronous generator induced voltage on phase A | direct |
| EfB | 0..1 Complex |
COP: Synchronous generator induced voltage on phase B | direct |
| EfC | 0..1 Complex |
COP: Synchronous generator induced voltage on phase C | direct |
| Vrotor_A | 0..1 Complex |
COP: Induction generator induced voltage on phase A in p | direct |
| Vrotor_B | 0..1 Complex |
COP: Induction generator induced voltage on phase B in p | direct |
| Vrotor_C | 0..1 Complex |
COP: Induction generator induced voltage on phase C in p | direct |
| Irotor_A | 0..1 Complex |
COP: Induction generator induced current on phase A in p | direct |
| Irotor_B | 0..1 Complex |
COP: Induction generator induced current on phase B in p | direct |
| Irotor_C | 0..1 Complex |
COP: Induction generator induced current on phase C in p | direct |
| internal_model_current_convergence | 0..1 Float |
Convergence value for internal current calculations | direct |
| Vapu | 0..1 Complex |
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... | direct |
| Vbpu | 0..1 Complex |
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... | direct |
| Vcpu | 0..1 Complex |
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... | direct |
| Iapu | 0..1 Complex |
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... | direct |
| Ibpu | 0..1 Complex |
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... | direct |
| Icpu | 0..1 Complex |
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... | direct |
| value_Circuit_V_A | 0..1 Complex |
CHECKPOINT_VAR: value holder for voltage values - element 0 | direct |
| value_Circuit_V_B | 0..1 Complex |
CHECKPOINT_VAR: value holder for voltage values - element 1 | direct |
| value_Circuit_V_C | 0..1 Complex |
CHECKPOINT_VAR: value holder for voltage values - element 2 | direct |
| value_Line_I_A | 0..1 Complex |
CHECKPOINT_VAR: value holder for current values - element 0 | direct |
| value_Line_I_B | 0..1 Complex |
CHECKPOINT_VAR: value holder for current values - element 1 | direct |
| value_Line_I_C | 0..1 Complex |
CHECKPOINT_VAR: value holder for current values - element 2 | direct |
| value_Line12 | 0..1 Complex |
CHECKPOINT_VAR: value holder for line current 12 in triplex metering | direct |
| prev_current_A | 0..1 Complex |
CHECKPOINT_VAR: internal variable for prev_current[0] | direct |
| prev_current_B | 0..1 Complex |
CHECKPOINT_VAR: internal variable for prev_current[1] | direct |
| prev_current_C | 0..1 Complex |
CHECKPOINT_VAR: internal variable for prev_current[2] | direct |
| NR_first_run | 0..1 Boolean |
CHECKPOINT_VAR: internal variable for NR_first_run | direct |
| prev_current12 | 0..1 Complex |
CHECKPOINT_VAR: internal variable for prev_current12 | direct |
| phases | 0..1 String |
Specifies which phases to connect to - currently triplex mode is only support... | direct |
| name | 1 String |
The object's name; unique across the model | GlmObject |
| parent | 0..1 String |
The parent object's name | GlmObject |
| groupid | 0..1 String |
Free-text group label | GlmObject |
| latitude | 0..1 String |
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) | GlmObject |
| longitude | 0..1 String |
Longitude, as written | GlmObject |
| in_svc | 0..1 String |
Timestamp the object enters service | GlmObject |
| out_svc | 0..1 String |
Timestamp the object leaves service | GlmObject |
| rank | 0..1 String |
Solver rank | GlmObject |
| flags | 0..1 String |
Core object flags | GlmObject |
Comments¶
- CIMHub does not convert this class. The importer reads no property of it and lists it, with its count, on the master's not-mapped comment; the exporter writes none.
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridlabd.org/schema/glm
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | glm:WindturbDg |
| native | glm:WindturbDg |
LinkML Source¶
Direct¶
name: windturb_dg
description: 'Copyright (C) 2008 Battelle Memorial Institute
@file windturb_dg.cpp
@defgroup windturb_dg Wind Turbine gensets
@ingroup generators
Inherits from: gld_object
Type: Instance (network topology element)
Note: Inherits from gld_object (not in generators module)'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: glm_object
attributes:
Gen_status:
name: Gen_status
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Gen_status
description: 'COP: Generator is currently available to supply power'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: string
required: false
Gen_type:
name: Gen_type
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Gen_type
description: 'COP: Standard synchronous generator; is also used to ''fake'' a
doubly-fed induction generator for now'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- diesel_dg
- windturb_dg
range: GenType
required: false
Gen_mode:
name: Gen_mode
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Gen_mode
description: 'COP: Maintains the real and reactive output at the terminals - currently
unsupported'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: string
required: false
Turbine_Model:
name: Turbine_Model
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Turbine_Model
description: Generic model for a 1.5MW turbine, power curve implementation
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: string
required: false
Turbine_implementation:
name: Turbine_implementation
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Turbine_implementation
description: Wind turbine implementation based on Generic Power Curve
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: string
required: false
Wind_speed_source:
name: Wind_speed_source
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Wind_speed_source
description: The climate data specifying the wind speed
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: string
required: false
turbine_height:
name: turbine_height
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: turbine_height[m]
description: Describes the height of the wind turbine hub above the ground
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m
roughness_length_factor:
name: roughness_length_factor
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: roughness_length_factor
description: European Wind Atlas unitless correction factor for adjusting wind
speed at various heights above ground and terrain types, default=0.055
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
blade_diam:
name: blade_diam
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: blade_diam[m]
description: 'COP: Diameter of blades'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m
blade_diameter:
name: blade_diameter
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: blade_diameter[m]
description: 'COP: Diameter of blades'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m
cut_in_ws:
name: cut_in_ws
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: cut_in_ws[m/s]
description: 'COP: Minimum wind speed for generator operation'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
cut_out_ws:
name: cut_out_ws
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: cut_out_ws[m/s]
description: 'COP: Maximum wind speed for generator operation'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
ws_rated:
name: ws_rated
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: ws_rated[m/s]
description: 'COP: Rated wind speed for generator operation'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
ws_maxcp:
name: ws_maxcp
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: ws_maxcp[m/s]
description: 'COP: Wind speed at which generator reaches maximum Cp'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
Cp_max:
name: Cp_max
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Cp_max[pu]
description: 'COP: Maximum coefficient of performance'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
Cp_rated:
name: Cp_rated
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Cp_rated[pu]
description: 'COP: Rated coefficient of performance'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
Cp:
name: Cp
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Cp[pu]
description: 'COP: Calculated coefficient of performance'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
Rated_VA:
name: Rated_VA
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rated_VA[VA]
description: Rated generator power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- diesel_dg
- windturb_dg
range: float
required: false
unit:
ucum_code: VA
Rated_V:
name: Rated_V
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rated_V[V]
description: 'COP: Rated generator terminal voltage'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- diesel_dg
- windturb_dg
range: float
required: false
unit:
ucum_code: V
Pconv:
name: Pconv
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pconv[W]
description: 'COP: Amount of electrical power converted from mechanical power
delivered'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: W
P_converted:
name: P_converted
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: P_converted[W]
description: 'COP: Amount of electrical power converted from mechanical power
delivered'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: W
GenElecEff:
name: GenElecEff
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: GenElecEff[%]
description: 'COP: Calculated generator electrical efficiency'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: '%'
generator_efficiency:
name: generator_efficiency
annotations:
order:
tag: order
value: 23
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: generator_efficiency[%]
description: 'COP: Calculated generator electrical efficiency'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: '%'
TotalRealPow:
name: TotalRealPow
annotations:
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: TotalRealPow[W]
description: Total real power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: W
total_real_power:
name: total_real_power
annotations:
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: total_real_power[W]
description: Total real power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: W
TotalReacPow:
name: TotalReacPow
annotations:
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: TotalReacPow[VA]
description: Total reactive power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: VA
total_reactive_power:
name: total_reactive_power
annotations:
order:
tag: order
value: 27
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: total_reactive_power[VA]
description: Total reactive power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: VA
power_A:
name: power_A
annotations:
order:
tag: order
value: 28
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_A[VA]
description: Total complex power injected on phase A
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_B:
name: power_B
annotations:
order:
tag: order
value: 29
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_B[VA]
description: Total complex power injected on phase B
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_C:
name: power_C
annotations:
order:
tag: order
value: 30
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_C[VA]
description: Total complex power injected on phase C
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_12:
name: power_12
annotations:
order:
tag: order
value: 31
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_12[VA]
description: Triplex mode - Total complex power on line 1 and 2
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- triplex_node
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
WSadj:
name: WSadj
annotations:
order:
tag: order
value: 32
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: WSadj[m/s]
description: Speed of wind at hub height
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
wind_speed_adjusted:
name: wind_speed_adjusted
annotations:
order:
tag: order
value: 33
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: wind_speed_adjusted[m/s]
description: Speed of wind at hub height
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
Wind_Speed:
name: Wind_Speed
annotations:
order:
tag: order
value: 34
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Wind_Speed[m/s]
description: Wind speed at 5-15m level (typical measurement height)
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
wind_speed:
name: wind_speed
annotations:
order:
tag: order
value: 35
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: wind_speed[m/s]
description: Wind speed at 5-15m level (typical measurement height)
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- solar
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
air_density:
name: air_density
annotations:
order:
tag: order
value: 36
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: air_density[kg/m^3]
description: 'COP: Estimated air density'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: kg/m^3
wind_speed_hub_ht:
name: wind_speed_hub_ht
annotations:
order:
tag: order
value: 37
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: wind_speed_hub_ht[m/s]
description: Wind speed at hub height. This is an input
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
R_stator:
name: R_stator
annotations:
order:
tag: order
value: 38
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_stator[pu*Ohm]
description: 'COP: Induction generator primary stator resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
X_stator:
name: X_stator
annotations:
order:
tag: order
value: 39
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: X_stator[pu*Ohm]
description: 'COP: Induction generator primary stator reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
R_rotor:
name: R_rotor
annotations:
order:
tag: order
value: 40
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_rotor[pu*Ohm]
description: 'COP: Induction generator primary rotor resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
X_rotor:
name: X_rotor
annotations:
order:
tag: order
value: 41
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: X_rotor[pu*Ohm]
description: 'COP: Induction generator primary rotor reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
R_core:
name: R_core
annotations:
order:
tag: order
value: 42
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_core[pu*Ohm]
description: 'COP: Induction generator primary core resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
X_magnetic:
name: X_magnetic
annotations:
order:
tag: order
value: 43
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: X_magnetic[pu*Ohm]
description: 'COP: Induction generator primary core reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Max_Vrotor:
name: Max_Vrotor
annotations:
order:
tag: order
value: 44
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Max_Vrotor[pu*V]
description: 'COP: Induction generator maximum induced rotor voltage in p.u.,
e.g. 1.2'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*V
Min_Vrotor:
name: Min_Vrotor
annotations:
order:
tag: order
value: 45
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Min_Vrotor[pu*V]
description: 'COP: Induction generator minimum induced rotor voltage in p.u.,
e.g. 0.8'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*V
Rs:
name: Rs
annotations:
order:
tag: order
value: 46
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rs[pu*Ohm]
description: 'COP: Synchronous generator primary stator resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- motor
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Xs:
name: Xs
annotations:
order:
tag: order
value: 47
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Xs[pu*Ohm]
description: 'COP: Synchronous generator primary stator reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- motor
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Rg:
name: Rg
annotations:
order:
tag: order
value: 48
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rg[pu*Ohm]
description: 'COP: Synchronous generator grounding resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Xg:
name: Xg
annotations:
order:
tag: order
value: 49
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Xg[pu*Ohm]
description: 'COP: Synchronous generator grounding reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Max_Ef:
name: Max_Ef
annotations:
order:
tag: order
value: 50
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Max_Ef[pu*V]
description: 'COP: Synchronous generator maximum induced rotor voltage in p.u.,
e.g. 0.8'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*V
Min_Ef:
name: Min_Ef
annotations:
order:
tag: order
value: 51
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Min_Ef[pu*V]
description: 'COP: Synchronous generator minimum induced rotor voltage in p.u.,
e.g. 0.8'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*V
pf:
name: pf
annotations:
order:
tag: order
value: 52
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf[pu]
description: 'COP: Desired power factor in CONSTANTP mode (can be modified over
time)'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
power_factor:
name: power_factor
annotations:
order:
tag: order
value: 53
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: power_factor[pu]
description: 'COP: Desired power factor in CONSTANTP mode (can be modified over
time)'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- performance_motor
- battery
- inverter
- windturb_dg
- residential_enduse
range: float
required: false
unit:
ucum_code: pu
power_curve_csv:
name: power_curve_csv
annotations:
order:
tag: order
value: 54
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: power_curve_csv
description: Name of .csv file containing user defined power curve
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: string
required: false
power_curve_pu:
name: power_curve_pu
annotations:
order:
tag: order
value: 55
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: power_curve_pu
description: Flag when set indicates that user provided power curve has power
values in p.u. Defaults to false
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: boolean
required: false
voltage_A:
name: voltage_A
annotations:
order:
tag: order
value: 56
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_A[V]
description: Terminal voltage on phase A
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
voltage_B:
name: voltage_B
annotations:
order:
tag: order
value: 57
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_B[V]
description: Terminal voltage on phase B
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
voltage_C:
name: voltage_C
annotations:
order:
tag: order
value: 58
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_C[V]
description: Terminal voltage on phase C
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
voltage_12:
name: voltage_12
annotations:
order:
tag: order
value: 59
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_12[V]
description: Triplex mode - Voltage between line 1 and line 2
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- triplex_node
- windturb_dg
- house
range: Complex
required: false
unit:
ucum_code: V
voltage_1N:
name: voltage_1N
annotations:
order:
tag: order
value: 60
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_1N[V]
description: Triplex mode - Voltage between line 1 and the neutral N
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- triplex_node
- windturb_dg
- house
range: Complex
required: false
unit:
ucum_code: V
voltage_2N:
name: voltage_2N
annotations:
order:
tag: order
value: 61
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_2N[V]
description: Triplex mode - Voltage between line 2 and the neutral N
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- triplex_node
- windturb_dg
- house
range: Complex
required: false
unit:
ucum_code: V
current_A:
name: current_A
annotations:
order:
tag: order
value: 62
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_A[A]
description: Calculated terminal current on phase A
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: A
current_B:
name: current_B
annotations:
order:
tag: order
value: 63
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_B[A]
description: Calculated terminal current on phase B
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: A
current_C:
name: current_C
annotations:
order:
tag: order
value: 64
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_C[A]
description: Calculated terminal current on phase C
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: A
current_12:
name: current_12
annotations:
order:
tag: order
value: 65
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_12[A]
description: Triplex mode - Calculated line current 12
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- triplex_node
- windturb_dg
range: Complex
required: false
unit:
ucum_code: A
EfA:
name: EfA
annotations:
order:
tag: order
value: 66
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: EfA[V]
description: 'COP: Synchronous generator induced voltage on phase A'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
EfB:
name: EfB
annotations:
order:
tag: order
value: 67
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: EfB[V]
description: 'COP: Synchronous generator induced voltage on phase B'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
EfC:
name: EfC
annotations:
order:
tag: order
value: 68
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: EfC[V]
description: 'COP: Synchronous generator induced voltage on phase C'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Vrotor_A:
name: Vrotor_A
annotations:
order:
tag: order
value: 69
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vrotor_A[V]
description: 'COP: Induction generator induced voltage on phase A in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Vrotor_B:
name: Vrotor_B
annotations:
order:
tag: order
value: 70
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vrotor_B[V]
description: 'COP: Induction generator induced voltage on phase B in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Vrotor_C:
name: Vrotor_C
annotations:
order:
tag: order
value: 71
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vrotor_C[V]
description: 'COP: Induction generator induced voltage on phase C in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Irotor_A:
name: Irotor_A
annotations:
order:
tag: order
value: 72
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Irotor_A[V]
description: 'COP: Induction generator induced current on phase A in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Irotor_B:
name: Irotor_B
annotations:
order:
tag: order
value: 73
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Irotor_B[V]
description: 'COP: Induction generator induced current on phase B in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Irotor_C:
name: Irotor_C
annotations:
order:
tag: order
value: 74
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Irotor_C[V]
description: 'COP: Induction generator induced current on phase C in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
internal_model_current_convergence:
name: internal_model_current_convergence
annotations:
order:
tag: order
value: 75
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: internal_model_current_convergence[pu]
description: Convergence value for internal current calculations
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
Vapu:
name: Vapu
annotations:
order:
tag: order
value: 76
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vapu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Vapu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
Vbpu:
name: Vbpu
annotations:
order:
tag: order
value: 77
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vbpu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Vbpu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
Vcpu:
name: Vcpu
annotations:
order:
tag: order
value: 78
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vcpu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Vcpu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
Iapu:
name: Iapu
annotations:
order:
tag: order
value: 79
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Iapu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Iapu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
Ibpu:
name: Ibpu
annotations:
order:
tag: order
value: 80
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Ibpu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Ibpu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
Icpu:
name: Icpu
annotations:
order:
tag: order
value: 81
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Icpu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Icpu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
value_Circuit_V_A:
name: value_Circuit_V_A
annotations:
order:
tag: order
value: 82
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Circuit_V_A
description: 'CHECKPOINT_VAR: value holder for voltage values - element 0'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Circuit_V_B:
name: value_Circuit_V_B
annotations:
order:
tag: order
value: 83
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Circuit_V_B
description: 'CHECKPOINT_VAR: value holder for voltage values - element 1'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Circuit_V_C:
name: value_Circuit_V_C
annotations:
order:
tag: order
value: 84
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Circuit_V_C
description: 'CHECKPOINT_VAR: value holder for voltage values - element 2'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Line_I_A:
name: value_Line_I_A
annotations:
order:
tag: order
value: 85
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Line_I_A
description: 'CHECKPOINT_VAR: value holder for current values - element 0'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Line_I_B:
name: value_Line_I_B
annotations:
order:
tag: order
value: 86
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Line_I_B
description: 'CHECKPOINT_VAR: value holder for current values - element 1'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Line_I_C:
name: value_Line_I_C
annotations:
order:
tag: order
value: 87
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Line_I_C
description: 'CHECKPOINT_VAR: value holder for current values - element 2'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Line12:
name: value_Line12
annotations:
order:
tag: order
value: 88
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Line12
description: 'CHECKPOINT_VAR: value holder for line current 12 in triplex metering'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
prev_current_A:
name: prev_current_A
annotations:
order:
tag: order
value: 89
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_current_A
description: 'CHECKPOINT_VAR: internal variable for prev_current[0]'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
prev_current_B:
name: prev_current_B
annotations:
order:
tag: order
value: 90
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_current_B
description: 'CHECKPOINT_VAR: internal variable for prev_current[1]'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
prev_current_C:
name: prev_current_C
annotations:
order:
tag: order
value: 91
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_current_C
description: 'CHECKPOINT_VAR: internal variable for prev_current[2]'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
NR_first_run:
name: NR_first_run
annotations:
order:
tag: order
value: 92
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: NR_first_run
description: 'CHECKPOINT_VAR: internal variable for NR_first_run'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: boolean
required: false
prev_current12:
name: prev_current12
annotations:
order:
tag: order
value: 93
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_current12
description: 'CHECKPOINT_VAR: internal variable for prev_current12'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
domain_of:
- windturb_dg
range: Complex
required: false
phases:
name: phases
annotations:
order:
tag: order
value: 94
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: phases
description: Specifies which phases to connect to - currently triplex mode is
only supported for power curve implementation
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
domain_of:
- powerflow_object
- inverter
- rectifier
- windturb_dg
range: string
required: false
Induced¶
name: windturb_dg
description: 'Copyright (C) 2008 Battelle Memorial Institute
@file windturb_dg.cpp
@defgroup windturb_dg Wind Turbine gensets
@ingroup generators
Inherits from: gld_object
Type: Instance (network topology element)
Note: Inherits from gld_object (not in generators module)'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: glm_object
attributes:
Gen_status:
name: Gen_status
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Gen_status
description: 'COP: Generator is currently available to supply power'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: string
required: false
Gen_type:
name: Gen_type
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Gen_type
description: 'COP: Standard synchronous generator; is also used to ''fake'' a
doubly-fed induction generator for now'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- diesel_dg
- windturb_dg
range: GenType
required: false
Gen_mode:
name: Gen_mode
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Gen_mode
description: 'COP: Maintains the real and reactive output at the terminals - currently
unsupported'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: string
required: false
Turbine_Model:
name: Turbine_Model
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Turbine_Model
description: Generic model for a 1.5MW turbine, power curve implementation
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: string
required: false
Turbine_implementation:
name: Turbine_implementation
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Turbine_implementation
description: Wind turbine implementation based on Generic Power Curve
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: string
required: false
Wind_speed_source:
name: Wind_speed_source
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: Wind_speed_source
description: The climate data specifying the wind speed
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: string
required: false
turbine_height:
name: turbine_height
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: turbine_height[m]
description: Describes the height of the wind turbine hub above the ground
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m
roughness_length_factor:
name: roughness_length_factor
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: roughness_length_factor
description: European Wind Atlas unitless correction factor for adjusting wind
speed at various heights above ground and terrain types, default=0.055
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
blade_diam:
name: blade_diam
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: blade_diam[m]
description: 'COP: Diameter of blades'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m
blade_diameter:
name: blade_diameter
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: blade_diameter[m]
description: 'COP: Diameter of blades'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m
cut_in_ws:
name: cut_in_ws
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: cut_in_ws[m/s]
description: 'COP: Minimum wind speed for generator operation'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
cut_out_ws:
name: cut_out_ws
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: cut_out_ws[m/s]
description: 'COP: Maximum wind speed for generator operation'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
ws_rated:
name: ws_rated
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: ws_rated[m/s]
description: 'COP: Rated wind speed for generator operation'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
ws_maxcp:
name: ws_maxcp
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: ws_maxcp[m/s]
description: 'COP: Wind speed at which generator reaches maximum Cp'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
Cp_max:
name: Cp_max
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Cp_max[pu]
description: 'COP: Maximum coefficient of performance'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
Cp_rated:
name: Cp_rated
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Cp_rated[pu]
description: 'COP: Rated coefficient of performance'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
Cp:
name: Cp
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Cp[pu]
description: 'COP: Calculated coefficient of performance'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
Rated_VA:
name: Rated_VA
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rated_VA[VA]
description: Rated generator power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- diesel_dg
- windturb_dg
range: float
required: false
unit:
ucum_code: VA
Rated_V:
name: Rated_V
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rated_V[V]
description: 'COP: Rated generator terminal voltage'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- diesel_dg
- windturb_dg
range: float
required: false
unit:
ucum_code: V
Pconv:
name: Pconv
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pconv[W]
description: 'COP: Amount of electrical power converted from mechanical power
delivered'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: W
P_converted:
name: P_converted
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: P_converted[W]
description: 'COP: Amount of electrical power converted from mechanical power
delivered'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: W
GenElecEff:
name: GenElecEff
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: GenElecEff[%]
description: 'COP: Calculated generator electrical efficiency'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: '%'
generator_efficiency:
name: generator_efficiency
annotations:
order:
tag: order
value: 23
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: generator_efficiency[%]
description: 'COP: Calculated generator electrical efficiency'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: '%'
TotalRealPow:
name: TotalRealPow
annotations:
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: TotalRealPow[W]
description: Total real power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: W
total_real_power:
name: total_real_power
annotations:
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: total_real_power[W]
description: Total real power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: W
TotalReacPow:
name: TotalReacPow
annotations:
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: TotalReacPow[VA]
description: Total reactive power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: VA
total_reactive_power:
name: total_reactive_power
annotations:
order:
tag: order
value: 27
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: total_reactive_power[VA]
description: Total reactive power output
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: VA
power_A:
name: power_A
annotations:
order:
tag: order
value: 28
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_A[VA]
description: Total complex power injected on phase A
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_B:
name: power_B
annotations:
order:
tag: order
value: 29
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_B[VA]
description: Total complex power injected on phase B
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_C:
name: power_C
annotations:
order:
tag: order
value: 30
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_C[VA]
description: Total complex power injected on phase C
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_12:
name: power_12
annotations:
order:
tag: order
value: 31
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_12[VA]
description: Triplex mode - Total complex power on line 1 and 2
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- triplex_node
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
WSadj:
name: WSadj
annotations:
order:
tag: order
value: 32
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: WSadj[m/s]
description: Speed of wind at hub height
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
wind_speed_adjusted:
name: wind_speed_adjusted
annotations:
order:
tag: order
value: 33
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: wind_speed_adjusted[m/s]
description: Speed of wind at hub height
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
Wind_Speed:
name: Wind_Speed
annotations:
order:
tag: order
value: 34
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Wind_Speed[m/s]
description: Wind speed at 5-15m level (typical measurement height)
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
wind_speed:
name: wind_speed
annotations:
order:
tag: order
value: 35
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: wind_speed[m/s]
description: Wind speed at 5-15m level (typical measurement height)
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- solar
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
air_density:
name: air_density
annotations:
order:
tag: order
value: 36
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: air_density[kg/m^3]
description: 'COP: Estimated air density'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: kg/m^3
wind_speed_hub_ht:
name: wind_speed_hub_ht
annotations:
order:
tag: order
value: 37
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: wind_speed_hub_ht[m/s]
description: Wind speed at hub height. This is an input
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: m/s
R_stator:
name: R_stator
annotations:
order:
tag: order
value: 38
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_stator[pu*Ohm]
description: 'COP: Induction generator primary stator resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
X_stator:
name: X_stator
annotations:
order:
tag: order
value: 39
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: X_stator[pu*Ohm]
description: 'COP: Induction generator primary stator reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
R_rotor:
name: R_rotor
annotations:
order:
tag: order
value: 40
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_rotor[pu*Ohm]
description: 'COP: Induction generator primary rotor resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
X_rotor:
name: X_rotor
annotations:
order:
tag: order
value: 41
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: X_rotor[pu*Ohm]
description: 'COP: Induction generator primary rotor reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
R_core:
name: R_core
annotations:
order:
tag: order
value: 42
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_core[pu*Ohm]
description: 'COP: Induction generator primary core resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
X_magnetic:
name: X_magnetic
annotations:
order:
tag: order
value: 43
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: X_magnetic[pu*Ohm]
description: 'COP: Induction generator primary core reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Max_Vrotor:
name: Max_Vrotor
annotations:
order:
tag: order
value: 44
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Max_Vrotor[pu*V]
description: 'COP: Induction generator maximum induced rotor voltage in p.u.,
e.g. 1.2'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*V
Min_Vrotor:
name: Min_Vrotor
annotations:
order:
tag: order
value: 45
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Min_Vrotor[pu*V]
description: 'COP: Induction generator minimum induced rotor voltage in p.u.,
e.g. 0.8'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*V
Rs:
name: Rs
annotations:
order:
tag: order
value: 46
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rs[pu*Ohm]
description: 'COP: Synchronous generator primary stator resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- motor
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Xs:
name: Xs
annotations:
order:
tag: order
value: 47
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Xs[pu*Ohm]
description: 'COP: Synchronous generator primary stator reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- motor
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Rg:
name: Rg
annotations:
order:
tag: order
value: 48
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rg[pu*Ohm]
description: 'COP: Synchronous generator grounding resistance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Xg:
name: Xg
annotations:
order:
tag: order
value: 49
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Xg[pu*Ohm]
description: 'COP: Synchronous generator grounding reactance in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*Ohm
Max_Ef:
name: Max_Ef
annotations:
order:
tag: order
value: 50
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Max_Ef[pu*V]
description: 'COP: Synchronous generator maximum induced rotor voltage in p.u.,
e.g. 0.8'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*V
Min_Ef:
name: Min_Ef
annotations:
order:
tag: order
value: 51
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Min_Ef[pu*V]
description: 'COP: Synchronous generator minimum induced rotor voltage in p.u.,
e.g. 0.8'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu*V
pf:
name: pf
annotations:
order:
tag: order
value: 52
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf[pu]
description: 'COP: Desired power factor in CONSTANTP mode (can be modified over
time)'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
power_factor:
name: power_factor
annotations:
order:
tag: order
value: 53
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: power_factor[pu]
description: 'COP: Desired power factor in CONSTANTP mode (can be modified over
time)'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- performance_motor
- battery
- inverter
- windturb_dg
- residential_enduse
range: float
required: false
unit:
ucum_code: pu
power_curve_csv:
name: power_curve_csv
annotations:
order:
tag: order
value: 54
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: power_curve_csv
description: Name of .csv file containing user defined power curve
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: string
required: false
power_curve_pu:
name: power_curve_pu
annotations:
order:
tag: order
value: 55
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: power_curve_pu
description: Flag when set indicates that user provided power curve has power
values in p.u. Defaults to false
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: boolean
required: false
voltage_A:
name: voltage_A
annotations:
order:
tag: order
value: 56
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_A[V]
description: Terminal voltage on phase A
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
voltage_B:
name: voltage_B
annotations:
order:
tag: order
value: 57
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_B[V]
description: Terminal voltage on phase B
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
voltage_C:
name: voltage_C
annotations:
order:
tag: order
value: 58
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_C[V]
description: Terminal voltage on phase C
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
voltage_12:
name: voltage_12
annotations:
order:
tag: order
value: 59
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_12[V]
description: Triplex mode - Voltage between line 1 and line 2
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- triplex_node
- windturb_dg
- house
range: Complex
required: false
unit:
ucum_code: V
voltage_1N:
name: voltage_1N
annotations:
order:
tag: order
value: 60
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_1N[V]
description: Triplex mode - Voltage between line 1 and the neutral N
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- triplex_node
- windturb_dg
- house
range: Complex
required: false
unit:
ucum_code: V
voltage_2N:
name: voltage_2N
annotations:
order:
tag: order
value: 61
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: voltage_2N[V]
description: Triplex mode - Voltage between line 2 and the neutral N
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- triplex_node
- windturb_dg
- house
range: Complex
required: false
unit:
ucum_code: V
current_A:
name: current_A
annotations:
order:
tag: order
value: 62
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_A[A]
description: Calculated terminal current on phase A
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: A
current_B:
name: current_B
annotations:
order:
tag: order
value: 63
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_B[A]
description: Calculated terminal current on phase B
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: A
current_C:
name: current_C
annotations:
order:
tag: order
value: 64
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_C[A]
description: Calculated terminal current on phase C
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- node
- rectifier
- windturb_dg
range: Complex
required: false
unit:
ucum_code: A
current_12:
name: current_12
annotations:
order:
tag: order
value: 65
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: current_12[A]
description: Triplex mode - Calculated line current 12
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- triplex_node
- windturb_dg
range: Complex
required: false
unit:
ucum_code: A
EfA:
name: EfA
annotations:
order:
tag: order
value: 66
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: EfA[V]
description: 'COP: Synchronous generator induced voltage on phase A'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
EfB:
name: EfB
annotations:
order:
tag: order
value: 67
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: EfB[V]
description: 'COP: Synchronous generator induced voltage on phase B'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
EfC:
name: EfC
annotations:
order:
tag: order
value: 68
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: EfC[V]
description: 'COP: Synchronous generator induced voltage on phase C'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Vrotor_A:
name: Vrotor_A
annotations:
order:
tag: order
value: 69
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vrotor_A[V]
description: 'COP: Induction generator induced voltage on phase A in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Vrotor_B:
name: Vrotor_B
annotations:
order:
tag: order
value: 70
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vrotor_B[V]
description: 'COP: Induction generator induced voltage on phase B in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Vrotor_C:
name: Vrotor_C
annotations:
order:
tag: order
value: 71
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vrotor_C[V]
description: 'COP: Induction generator induced voltage on phase C in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Irotor_A:
name: Irotor_A
annotations:
order:
tag: order
value: 72
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Irotor_A[V]
description: 'COP: Induction generator induced current on phase A in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Irotor_B:
name: Irotor_B
annotations:
order:
tag: order
value: 73
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Irotor_B[V]
description: 'COP: Induction generator induced current on phase B in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
Irotor_C:
name: Irotor_C
annotations:
order:
tag: order
value: 74
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Irotor_C[V]
description: 'COP: Induction generator induced current on phase C in p.u.'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
unit:
ucum_code: V
internal_model_current_convergence:
name: internal_model_current_convergence
annotations:
order:
tag: order
value: 75
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: internal_model_current_convergence[pu]
description: Convergence value for internal current calculations
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: float
required: false
unit:
ucum_code: pu
Vapu:
name: Vapu
annotations:
order:
tag: order
value: 76
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vapu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Vapu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
Vbpu:
name: Vbpu
annotations:
order:
tag: order
value: 77
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vbpu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Vbpu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
Vcpu:
name: Vcpu
annotations:
order:
tag: order
value: 78
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Vcpu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Vcpu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
Iapu:
name: Iapu
annotations:
order:
tag: order
value: 79
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Iapu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Iapu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
Ibpu:
name: Ibpu
annotations:
order:
tag: order
value: 80
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Ibpu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Ibpu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
Icpu:
name: Icpu
annotations:
order:
tag: order
value: 81
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: Icpu
description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
at terminals - Icpu'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
value_Circuit_V_A:
name: value_Circuit_V_A
annotations:
order:
tag: order
value: 82
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Circuit_V_A
description: 'CHECKPOINT_VAR: value holder for voltage values - element 0'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Circuit_V_B:
name: value_Circuit_V_B
annotations:
order:
tag: order
value: 83
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Circuit_V_B
description: 'CHECKPOINT_VAR: value holder for voltage values - element 1'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Circuit_V_C:
name: value_Circuit_V_C
annotations:
order:
tag: order
value: 84
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Circuit_V_C
description: 'CHECKPOINT_VAR: value holder for voltage values - element 2'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Line_I_A:
name: value_Line_I_A
annotations:
order:
tag: order
value: 85
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Line_I_A
description: 'CHECKPOINT_VAR: value holder for current values - element 0'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Line_I_B:
name: value_Line_I_B
annotations:
order:
tag: order
value: 86
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Line_I_B
description: 'CHECKPOINT_VAR: value holder for current values - element 1'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Line_I_C:
name: value_Line_I_C
annotations:
order:
tag: order
value: 87
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Line_I_C
description: 'CHECKPOINT_VAR: value holder for current values - element 2'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
value_Line12:
name: value_Line12
annotations:
order:
tag: order
value: 88
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: value_Line12
description: 'CHECKPOINT_VAR: value holder for line current 12 in triplex metering'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- battery
- windturb_dg
range: Complex
required: false
prev_current_A:
name: prev_current_A
annotations:
order:
tag: order
value: 89
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_current_A
description: 'CHECKPOINT_VAR: internal variable for prev_current[0]'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
prev_current_B:
name: prev_current_B
annotations:
order:
tag: order
value: 90
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_current_B
description: 'CHECKPOINT_VAR: internal variable for prev_current[1]'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
prev_current_C:
name: prev_current_C
annotations:
order:
tag: order
value: 91
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_current_C
description: 'CHECKPOINT_VAR: internal variable for prev_current[2]'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
NR_first_run:
name: NR_first_run
annotations:
order:
tag: order
value: 92
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: NR_first_run
description: 'CHECKPOINT_VAR: internal variable for NR_first_run'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: boolean
required: false
prev_current12:
name: prev_current12
annotations:
order:
tag: order
value: 93
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_current12
description: 'CHECKPOINT_VAR: internal variable for prev_current12'
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
rank: 1000
owner: windturb_dg
domain_of:
- windturb_dg
range: Complex
required: false
phases:
name: phases
annotations:
order:
tag: order
value: 94
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: phases
description: Specifies which phases to connect to - currently triplex mode is
only supported for power curve implementation
from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
owner: windturb_dg
domain_of:
- powerflow_object
- inverter
- rectifier
- windturb_dg
range: string
required: false
name:
name: name
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: name
description: The object's name; unique across the model.
comments:
- 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
(none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
share raises.'
from_schema: https://gridlabd.org/schema/glm/types/common
exact_mappings:
- cim:IdentifiedObject.name
rank: 1000
identifier: true
owner: windturb_dg
domain_of:
- glm_object
range: string
required: true
parent:
name: parent
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: parent
description: The parent object's name. A child node is solved as its parent's
bus; a nested object block sets it to the enclosing object.
comments:
- 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
on the root''s row; no object of its own. On a link it is not mapped.'
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: windturb_dg
domain_of:
- glm_object
range: string
groupid:
name: groupid
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: groupid
description: Free-text group label.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: windturb_dg
domain_of:
- glm_object
range: string
latitude:
name: latitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: latitude
description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: windturb_dg
domain_of:
- glm_object
range: string
longitude:
name: longitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: longitude
description: Longitude, as written.
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: windturb_dg
domain_of:
- glm_object
range: string
in_svc:
name: in_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: in_svc
description: Timestamp the object enters service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: windturb_dg
domain_of:
- glm_object
range: string
out_svc:
name: out_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: out_svc
description: Timestamp the object leaves service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: windturb_dg
domain_of:
- glm_object
range: string
rank:
name: rank
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: rank
description: Solver rank.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: windturb_dg
domain_of:
- glm_object
range: string
flags:
name: flags
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: flags
description: Core object flags.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: windturb_dg
domain_of:
- glm_object
range: string