Skip to content

Class: WindturbDg

Copyright (C) 2008 Battelle Memorial Institute

@file windturb_dg.cpp

@defgroup windturb_dg Wind Turbine gensets

@ingroup generators

__

Inherits from: gld_object

__

Type: Instance (network topology element)

__

Note: Inherits from gld_object (not in generators module)

URI: glm:WindturbDg

 classDiagram
    class WindturbDg
    click WindturbDg href "../WindturbDg/"
      GlmObject <|-- WindturbDg
        click GlmObject href "../GlmObject/"

      WindturbDg : air_density

      WindturbDg : blade_diam

      WindturbDg : blade_diameter

      WindturbDg : Cp

      WindturbDg : Cp_max

      WindturbDg : Cp_rated

      WindturbDg : current_12





        WindturbDg --> "0..1" Complex : current_12
        click Complex href "../Complex/"



      WindturbDg : current_A





        WindturbDg --> "0..1" Complex : current_A
        click Complex href "../Complex/"



      WindturbDg : current_B





        WindturbDg --> "0..1" Complex : current_B
        click Complex href "../Complex/"



      WindturbDg : current_C





        WindturbDg --> "0..1" Complex : current_C
        click Complex href "../Complex/"



      WindturbDg : cut_in_ws

      WindturbDg : cut_out_ws

      WindturbDg : EfA





        WindturbDg --> "0..1" Complex : EfA
        click Complex href "../Complex/"



      WindturbDg : EfB





        WindturbDg --> "0..1" Complex : EfB
        click Complex href "../Complex/"



      WindturbDg : EfC





        WindturbDg --> "0..1" Complex : EfC
        click Complex href "../Complex/"



      WindturbDg : flags

      WindturbDg : Gen_mode

      WindturbDg : Gen_status

      WindturbDg : Gen_type





        WindturbDg --> "0..1" GenType : Gen_type
        click GenType href "../GenType/"



      WindturbDg : GenElecEff

      WindturbDg : generator_efficiency

      WindturbDg : groupid

      WindturbDg : Iapu





        WindturbDg --> "0..1" Complex : Iapu
        click Complex href "../Complex/"



      WindturbDg : Ibpu





        WindturbDg --> "0..1" Complex : Ibpu
        click Complex href "../Complex/"



      WindturbDg : Icpu





        WindturbDg --> "0..1" Complex : Icpu
        click Complex href "../Complex/"



      WindturbDg : in_svc

      WindturbDg : internal_model_current_convergence

      WindturbDg : Irotor_A





        WindturbDg --> "0..1" Complex : Irotor_A
        click Complex href "../Complex/"



      WindturbDg : Irotor_B





        WindturbDg --> "0..1" Complex : Irotor_B
        click Complex href "../Complex/"



      WindturbDg : Irotor_C





        WindturbDg --> "0..1" Complex : Irotor_C
        click Complex href "../Complex/"



      WindturbDg : latitude

      WindturbDg : longitude

      WindturbDg : Max_Ef

      WindturbDg : Max_Vrotor

      WindturbDg : Min_Ef

      WindturbDg : Min_Vrotor

      WindturbDg : name

      WindturbDg : NR_first_run

      WindturbDg : out_svc

      WindturbDg : P_converted

      WindturbDg : parent

      WindturbDg : Pconv

      WindturbDg : pf

      WindturbDg : phases

      WindturbDg : power_12





        WindturbDg --> "0..1" Complex : power_12
        click Complex href "../Complex/"



      WindturbDg : power_A





        WindturbDg --> "0..1" Complex : power_A
        click Complex href "../Complex/"



      WindturbDg : power_B





        WindturbDg --> "0..1" Complex : power_B
        click Complex href "../Complex/"



      WindturbDg : power_C





        WindturbDg --> "0..1" Complex : power_C
        click Complex href "../Complex/"



      WindturbDg : power_curve_csv

      WindturbDg : power_curve_pu

      WindturbDg : power_factor

      WindturbDg : prev_current12





        WindturbDg --> "0..1" Complex : prev_current12
        click Complex href "../Complex/"



      WindturbDg : prev_current_A





        WindturbDg --> "0..1" Complex : prev_current_A
        click Complex href "../Complex/"



      WindturbDg : prev_current_B





        WindturbDg --> "0..1" Complex : prev_current_B
        click Complex href "../Complex/"



      WindturbDg : prev_current_C





        WindturbDg --> "0..1" Complex : prev_current_C
        click Complex href "../Complex/"



      WindturbDg : R_core

      WindturbDg : R_rotor

      WindturbDg : R_stator

      WindturbDg : rank

      WindturbDg : Rated_V

      WindturbDg : Rated_VA

      WindturbDg : Rg

      WindturbDg : roughness_length_factor

      WindturbDg : Rs

      WindturbDg : total_reactive_power

      WindturbDg : total_real_power

      WindturbDg : TotalReacPow

      WindturbDg : TotalRealPow

      WindturbDg : turbine_height

      WindturbDg : Turbine_implementation

      WindturbDg : Turbine_Model

      WindturbDg : value_Circuit_V_A





        WindturbDg --> "0..1" Complex : value_Circuit_V_A
        click Complex href "../Complex/"



      WindturbDg : value_Circuit_V_B





        WindturbDg --> "0..1" Complex : value_Circuit_V_B
        click Complex href "../Complex/"



      WindturbDg : value_Circuit_V_C





        WindturbDg --> "0..1" Complex : value_Circuit_V_C
        click Complex href "../Complex/"



      WindturbDg : value_Line12





        WindturbDg --> "0..1" Complex : value_Line12
        click Complex href "../Complex/"



      WindturbDg : value_Line_I_A





        WindturbDg --> "0..1" Complex : value_Line_I_A
        click Complex href "../Complex/"



      WindturbDg : value_Line_I_B





        WindturbDg --> "0..1" Complex : value_Line_I_B
        click Complex href "../Complex/"



      WindturbDg : value_Line_I_C





        WindturbDg --> "0..1" Complex : value_Line_I_C
        click Complex href "../Complex/"



      WindturbDg : Vapu





        WindturbDg --> "0..1" Complex : Vapu
        click Complex href "../Complex/"



      WindturbDg : Vbpu





        WindturbDg --> "0..1" Complex : Vbpu
        click Complex href "../Complex/"



      WindturbDg : Vcpu





        WindturbDg --> "0..1" Complex : Vcpu
        click Complex href "../Complex/"



      WindturbDg : voltage_12





        WindturbDg --> "0..1" Complex : voltage_12
        click Complex href "../Complex/"



      WindturbDg : voltage_1N





        WindturbDg --> "0..1" Complex : voltage_1N
        click Complex href "../Complex/"



      WindturbDg : voltage_2N





        WindturbDg --> "0..1" Complex : voltage_2N
        click Complex href "../Complex/"



      WindturbDg : voltage_A





        WindturbDg --> "0..1" Complex : voltage_A
        click Complex href "../Complex/"



      WindturbDg : voltage_B





        WindturbDg --> "0..1" Complex : voltage_B
        click Complex href "../Complex/"



      WindturbDg : voltage_C





        WindturbDg --> "0..1" Complex : voltage_C
        click Complex href "../Complex/"



      WindturbDg : Vrotor_A





        WindturbDg --> "0..1" Complex : Vrotor_A
        click Complex href "../Complex/"



      WindturbDg : Vrotor_B





        WindturbDg --> "0..1" Complex : Vrotor_B
        click Complex href "../Complex/"



      WindturbDg : Vrotor_C





        WindturbDg --> "0..1" Complex : Vrotor_C
        click Complex href "../Complex/"



      WindturbDg : Wind_Speed

      WindturbDg : wind_speed

      WindturbDg : wind_speed_adjusted

      WindturbDg : wind_speed_hub_ht

      WindturbDg : Wind_speed_source

      WindturbDg : ws_maxcp

      WindturbDg : ws_rated

      WindturbDg : WSadj

      WindturbDg : X_magnetic

      WindturbDg : X_rotor

      WindturbDg : X_stator

      WindturbDg : Xg

      WindturbDg : Xs

Inheritance

Slots

Name Cardinality and Range Description Inheritance
Gen_status 0..1
String
COP: Generator is currently available to supply power direct
Gen_type 0..1
GenType
COP: Standard synchronous generator; is also used to 'fake' a doubly-fed indu... direct
Gen_mode 0..1
String
COP: Maintains the real and reactive output at the terminals - currently unsu... direct
Turbine_Model 0..1
String
Generic model for a 1 direct
Turbine_implementation 0..1
String
Wind turbine implementation based on Generic Power Curve direct
Wind_speed_source 0..1
String
The climate data specifying the wind speed direct
turbine_height 0..1
Float
Describes the height of the wind turbine hub above the ground direct
roughness_length_factor 0..1
Float
European Wind Atlas unitless correction factor for adjusting wind speed at va... direct
blade_diam 0..1
Float
COP: Diameter of blades direct
blade_diameter 0..1
Float
COP: Diameter of blades direct
cut_in_ws 0..1
Float
COP: Minimum wind speed for generator operation direct
cut_out_ws 0..1
Float
COP: Maximum wind speed for generator operation direct
ws_rated 0..1
Float
COP: Rated wind speed for generator operation direct
ws_maxcp 0..1
Float
COP: Wind speed at which generator reaches maximum Cp direct
Cp_max 0..1
Float
COP: Maximum coefficient of performance direct
Cp_rated 0..1
Float
COP: Rated coefficient of performance direct
Cp 0..1
Float
COP: Calculated coefficient of performance direct
Rated_VA 0..1
Float
Rated generator power output direct
Rated_V 0..1
Float
COP: Rated generator terminal voltage direct
Pconv 0..1
Float
COP: Amount of electrical power converted from mechanical power delivered direct
P_converted 0..1
Float
COP: Amount of electrical power converted from mechanical power delivered direct
GenElecEff 0..1
Float
COP: Calculated generator electrical efficiency direct
generator_efficiency 0..1
Float
COP: Calculated generator electrical efficiency direct
TotalRealPow 0..1
Float
Total real power output direct
total_real_power 0..1
Float
Total real power output direct
TotalReacPow 0..1
Float
Total reactive power output direct
total_reactive_power 0..1
Float
Total reactive power output direct
power_A 0..1
Complex
Total complex power injected on phase A direct
power_B 0..1
Complex
Total complex power injected on phase B direct
power_C 0..1
Complex
Total complex power injected on phase C direct
power_12 0..1
Complex
Triplex mode - Total complex power on line 1 and 2 direct
WSadj 0..1
Float
Speed of wind at hub height direct
wind_speed_adjusted 0..1
Float
Speed of wind at hub height direct
Wind_Speed 0..1
Float
Wind speed at 5-15m level (typical measurement height) direct
wind_speed 0..1
Float
Wind speed at 5-15m level (typical measurement height) direct
air_density 0..1
Float
COP: Estimated air density direct
wind_speed_hub_ht 0..1
Float
Wind speed at hub height direct
R_stator 0..1
Float
COP: Induction generator primary stator resistance in p direct
X_stator 0..1
Float
COP: Induction generator primary stator reactance in p direct
R_rotor 0..1
Float
COP: Induction generator primary rotor resistance in p direct
X_rotor 0..1
Float
COP: Induction generator primary rotor reactance in p direct
R_core 0..1
Float
COP: Induction generator primary core resistance in p direct
X_magnetic 0..1
Float
COP: Induction generator primary core reactance in p direct
Max_Vrotor 0..1
Float
COP: Induction generator maximum induced rotor voltage in p direct
Min_Vrotor 0..1
Float
COP: Induction generator minimum induced rotor voltage in p direct
Rs 0..1
Float
COP: Synchronous generator primary stator resistance in p direct
Xs 0..1
Float
COP: Synchronous generator primary stator reactance in p direct
Rg 0..1
Float
COP: Synchronous generator grounding resistance in p direct
Xg 0..1
Float
COP: Synchronous generator grounding reactance in p direct
Max_Ef 0..1
Float
COP: Synchronous generator maximum induced rotor voltage in p direct
Min_Ef 0..1
Float
COP: Synchronous generator minimum induced rotor voltage in p direct
pf 0..1
Float
COP: Desired power factor in CONSTANTP mode (can be modified over time) direct
power_factor 0..1
Float
COP: Desired power factor in CONSTANTP mode (can be modified over time) direct
power_curve_csv 0..1
String
Name of direct
power_curve_pu 0..1
Boolean
Flag when set indicates that user provided power curve has power values in p direct
voltage_A 0..1
Complex
Terminal voltage on phase A direct
voltage_B 0..1
Complex
Terminal voltage on phase B direct
voltage_C 0..1
Complex
Terminal voltage on phase C direct
voltage_12 0..1
Complex
Triplex mode - Voltage between line 1 and line 2 direct
voltage_1N 0..1
Complex
Triplex mode - Voltage between line 1 and the neutral N direct
voltage_2N 0..1
Complex
Triplex mode - Voltage between line 2 and the neutral N direct
current_A 0..1
Complex
Calculated terminal current on phase A direct
current_B 0..1
Complex
Calculated terminal current on phase B direct
current_C 0..1
Complex
Calculated terminal current on phase C direct
current_12 0..1
Complex
Triplex mode - Calculated line current 12 direct
EfA 0..1
Complex
COP: Synchronous generator induced voltage on phase A direct
EfB 0..1
Complex
COP: Synchronous generator induced voltage on phase B direct
EfC 0..1
Complex
COP: Synchronous generator induced voltage on phase C direct
Vrotor_A 0..1
Complex
COP: Induction generator induced voltage on phase A in p direct
Vrotor_B 0..1
Complex
COP: Induction generator induced voltage on phase B in p direct
Vrotor_C 0..1
Complex
COP: Induction generator induced voltage on phase C in p direct
Irotor_A 0..1
Complex
COP: Induction generator induced current on phase A in p direct
Irotor_B 0..1
Complex
COP: Induction generator induced current on phase B in p direct
Irotor_C 0..1
Complex
COP: Induction generator induced current on phase C in p direct
internal_model_current_convergence 0..1
Float
Convergence value for internal current calculations direct
Vapu 0..1
Complex
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... direct
Vbpu 0..1
Complex
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... direct
Vcpu 0..1
Complex
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... direct
Iapu 0..1
Complex
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... direct
Ibpu 0..1
Complex
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... direct
Icpu 0..1
Complex
CHECKPOINT_VAR: Per unit voltage and current for Induction Generator at termi... direct
value_Circuit_V_A 0..1
Complex
CHECKPOINT_VAR: value holder for voltage values - element 0 direct
value_Circuit_V_B 0..1
Complex
CHECKPOINT_VAR: value holder for voltage values - element 1 direct
value_Circuit_V_C 0..1
Complex
CHECKPOINT_VAR: value holder for voltage values - element 2 direct
value_Line_I_A 0..1
Complex
CHECKPOINT_VAR: value holder for current values - element 0 direct
value_Line_I_B 0..1
Complex
CHECKPOINT_VAR: value holder for current values - element 1 direct
value_Line_I_C 0..1
Complex
CHECKPOINT_VAR: value holder for current values - element 2 direct
value_Line12 0..1
Complex
CHECKPOINT_VAR: value holder for line current 12 in triplex metering direct
prev_current_A 0..1
Complex
CHECKPOINT_VAR: internal variable for prev_current[0] direct
prev_current_B 0..1
Complex
CHECKPOINT_VAR: internal variable for prev_current[1] direct
prev_current_C 0..1
Complex
CHECKPOINT_VAR: internal variable for prev_current[2] direct
NR_first_run 0..1
Boolean
CHECKPOINT_VAR: internal variable for NR_first_run direct
prev_current12 0..1
Complex
CHECKPOINT_VAR: internal variable for prev_current12 direct
phases 0..1
String
Specifies which phases to connect to - currently triplex mode is only support... direct
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • CIMHub does not convert this class. The importer reads no property of it and lists it, with its count, on the master's not-mapped comment; the exporter writes none.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:WindturbDg
native glm:WindturbDg

LinkML Source

Direct

name: windturb_dg
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file windturb_dg.cpp

  @defgroup windturb_dg Wind Turbine gensets

  @ingroup generators


  Inherits from: gld_object


  Type: Instance (network topology element)


  Note: Inherits from gld_object (not in generators module)'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
  it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: glm_object
attributes:
  Gen_status:
    name: Gen_status
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Gen_status
    description: 'COP: Generator is currently available to supply power'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: string
    required: false
  Gen_type:
    name: Gen_type
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Gen_type
    description: 'COP: Standard synchronous generator; is also used to ''fake'' a
      doubly-fed induction generator for now'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - diesel_dg
    - windturb_dg
    range: GenType
    required: false
  Gen_mode:
    name: Gen_mode
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Gen_mode
    description: 'COP: Maintains the real and reactive output at the terminals - currently
      unsupported'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: string
    required: false
  Turbine_Model:
    name: Turbine_Model
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Turbine_Model
    description: Generic model for a 1.5MW turbine, power curve implementation
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: string
    required: false
  Turbine_implementation:
    name: Turbine_implementation
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Turbine_implementation
    description: Wind turbine implementation based on Generic Power Curve
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: string
    required: false
  Wind_speed_source:
    name: Wind_speed_source
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Wind_speed_source
    description: The climate data specifying the wind speed
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: string
    required: false
  turbine_height:
    name: turbine_height
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: turbine_height[m]
    description: Describes the height of the wind turbine hub above the ground
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m
  roughness_length_factor:
    name: roughness_length_factor
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: roughness_length_factor
    description: European Wind Atlas unitless correction factor for adjusting wind
      speed at various heights above ground and terrain types, default=0.055
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
  blade_diam:
    name: blade_diam
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: blade_diam[m]
    description: 'COP: Diameter of blades'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m
  blade_diameter:
    name: blade_diameter
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: blade_diameter[m]
    description: 'COP: Diameter of blades'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m
  cut_in_ws:
    name: cut_in_ws
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: cut_in_ws[m/s]
    description: 'COP: Minimum wind speed for generator operation'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  cut_out_ws:
    name: cut_out_ws
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: cut_out_ws[m/s]
    description: 'COP: Maximum wind speed for generator operation'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  ws_rated:
    name: ws_rated
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ws_rated[m/s]
    description: 'COP: Rated wind speed for generator operation'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  ws_maxcp:
    name: ws_maxcp
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ws_maxcp[m/s]
    description: 'COP: Wind speed at which generator reaches maximum Cp'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  Cp_max:
    name: Cp_max
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Cp_max[pu]
    description: 'COP: Maximum coefficient of performance'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  Cp_rated:
    name: Cp_rated
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Cp_rated[pu]
    description: 'COP: Rated coefficient of performance'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  Cp:
    name: Cp
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Cp[pu]
    description: 'COP: Calculated coefficient of performance'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  Rated_VA:
    name: Rated_VA
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rated_VA[VA]
    description: Rated generator power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - diesel_dg
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: VA
  Rated_V:
    name: Rated_V
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rated_V[V]
    description: 'COP: Rated generator terminal voltage'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - diesel_dg
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: V
  Pconv:
    name: Pconv
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pconv[W]
    description: 'COP: Amount of electrical power converted from mechanical power
      delivered'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: W
  P_converted:
    name: P_converted
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: P_converted[W]
    description: 'COP: Amount of electrical power converted from mechanical power
      delivered'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: W
  GenElecEff:
    name: GenElecEff
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GenElecEff[%]
    description: 'COP: Calculated generator electrical efficiency'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: '%'
  generator_efficiency:
    name: generator_efficiency
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: generator_efficiency[%]
    description: 'COP: Calculated generator electrical efficiency'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: '%'
  TotalRealPow:
    name: TotalRealPow
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: TotalRealPow[W]
    description: Total real power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: W
  total_real_power:
    name: total_real_power
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: total_real_power[W]
    description: Total real power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: W
  TotalReacPow:
    name: TotalReacPow
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: TotalReacPow[VA]
    description: Total reactive power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: VA
  total_reactive_power:
    name: total_reactive_power
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: total_reactive_power[VA]
    description: Total reactive power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: VA
  power_A:
    name: power_A
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_A[VA]
    description: Total complex power injected on phase A
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_B:
    name: power_B
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_B[VA]
    description: Total complex power injected on phase B
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_C:
    name: power_C
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_C[VA]
    description: Total complex power injected on phase C
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_12:
    name: power_12
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_12[VA]
    description: Triplex mode - Total complex power on line 1 and 2
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  WSadj:
    name: WSadj
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: WSadj[m/s]
    description: Speed of wind at hub height
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  wind_speed_adjusted:
    name: wind_speed_adjusted
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wind_speed_adjusted[m/s]
    description: Speed of wind at hub height
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  Wind_Speed:
    name: Wind_Speed
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Wind_Speed[m/s]
    description: Wind speed at 5-15m level (typical measurement height)
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  wind_speed:
    name: wind_speed
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wind_speed[m/s]
    description: Wind speed at 5-15m level (typical measurement height)
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - solar
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  air_density:
    name: air_density
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: air_density[kg/m^3]
    description: 'COP: Estimated air density'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: kg/m^3
  wind_speed_hub_ht:
    name: wind_speed_hub_ht
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wind_speed_hub_ht[m/s]
    description: Wind speed at hub height. This is an input
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  R_stator:
    name: R_stator
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_stator[pu*Ohm]
    description: 'COP: Induction generator primary stator resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  X_stator:
    name: X_stator
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: X_stator[pu*Ohm]
    description: 'COP: Induction generator primary stator reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  R_rotor:
    name: R_rotor
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_rotor[pu*Ohm]
    description: 'COP: Induction generator primary rotor resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  X_rotor:
    name: X_rotor
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: X_rotor[pu*Ohm]
    description: 'COP: Induction generator primary rotor reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  R_core:
    name: R_core
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_core[pu*Ohm]
    description: 'COP: Induction generator primary core resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  X_magnetic:
    name: X_magnetic
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: X_magnetic[pu*Ohm]
    description: 'COP: Induction generator primary core reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Max_Vrotor:
    name: Max_Vrotor
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Max_Vrotor[pu*V]
    description: 'COP: Induction generator maximum induced rotor voltage in p.u.,
      e.g. 1.2'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*V
  Min_Vrotor:
    name: Min_Vrotor
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Min_Vrotor[pu*V]
    description: 'COP: Induction generator minimum induced rotor voltage in p.u.,
      e.g. 0.8'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*V
  Rs:
    name: Rs
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rs[pu*Ohm]
    description: 'COP: Synchronous generator primary stator resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - motor
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Xs:
    name: Xs
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xs[pu*Ohm]
    description: 'COP: Synchronous generator primary stator reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - motor
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Rg:
    name: Rg
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rg[pu*Ohm]
    description: 'COP: Synchronous generator grounding resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Xg:
    name: Xg
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xg[pu*Ohm]
    description: 'COP: Synchronous generator grounding reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Max_Ef:
    name: Max_Ef
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Max_Ef[pu*V]
    description: 'COP: Synchronous generator maximum induced rotor voltage in p.u.,
      e.g. 0.8'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*V
  Min_Ef:
    name: Min_Ef
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Min_Ef[pu*V]
    description: 'COP: Synchronous generator minimum induced rotor voltage in p.u.,
      e.g. 0.8'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*V
  pf:
    name: pf
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf[pu]
    description: 'COP: Desired power factor in CONSTANTP mode (can be modified over
      time)'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  power_factor:
    name: power_factor
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_factor[pu]
    description: 'COP: Desired power factor in CONSTANTP mode (can be modified over
      time)'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - performance_motor
    - battery
    - inverter
    - windturb_dg
    - residential_enduse
    range: float
    required: false
    unit:
      ucum_code: pu
  power_curve_csv:
    name: power_curve_csv
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: power_curve_csv
    description: Name of .csv file containing user defined power curve
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: string
    required: false
  power_curve_pu:
    name: power_curve_pu
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: power_curve_pu
    description: Flag when set indicates that user provided power curve has power
      values in p.u. Defaults to false
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: boolean
    required: false
  voltage_A:
    name: voltage_A
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_A[V]
    description: Terminal voltage on phase A
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_B:
    name: voltage_B
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_B[V]
    description: Terminal voltage on phase B
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_C:
    name: voltage_C
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_C[V]
    description: Terminal voltage on phase C
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_12:
    name: voltage_12
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_12[V]
    description: Triplex mode - Voltage between line 1 and line 2
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_1N:
    name: voltage_1N
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_1N[V]
    description: Triplex mode - Voltage between line 1 and the neutral N
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_2N:
    name: voltage_2N
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_2N[V]
    description: Triplex mode - Voltage between line 2 and the neutral N
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  current_A:
    name: current_A
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_A[A]
    description: Calculated terminal current on phase A
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_B:
    name: current_B
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_B[A]
    description: Calculated terminal current on phase B
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_C:
    name: current_C
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_C[A]
    description: Calculated terminal current on phase C
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_12:
    name: current_12
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_12[A]
    description: Triplex mode - Calculated line current 12
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  EfA:
    name: EfA
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: EfA[V]
    description: 'COP: Synchronous generator induced voltage on phase A'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  EfB:
    name: EfB
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: EfB[V]
    description: 'COP: Synchronous generator induced voltage on phase B'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  EfC:
    name: EfC
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: EfC[V]
    description: 'COP: Synchronous generator induced voltage on phase C'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Vrotor_A:
    name: Vrotor_A
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vrotor_A[V]
    description: 'COP: Induction generator induced voltage on phase A in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Vrotor_B:
    name: Vrotor_B
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vrotor_B[V]
    description: 'COP: Induction generator induced voltage on phase B in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Vrotor_C:
    name: Vrotor_C
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vrotor_C[V]
    description: 'COP: Induction generator induced voltage on phase C in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Irotor_A:
    name: Irotor_A
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Irotor_A[V]
    description: 'COP: Induction generator induced current on phase A in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Irotor_B:
    name: Irotor_B
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Irotor_B[V]
    description: 'COP: Induction generator induced current on phase B in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Irotor_C:
    name: Irotor_C
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Irotor_C[V]
    description: 'COP: Induction generator induced current on phase C in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  internal_model_current_convergence:
    name: internal_model_current_convergence
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: internal_model_current_convergence[pu]
    description: Convergence value for internal current calculations
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  Vapu:
    name: Vapu
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vapu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Vapu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Vbpu:
    name: Vbpu
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vbpu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Vbpu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Vcpu:
    name: Vcpu
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vcpu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Vcpu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Iapu:
    name: Iapu
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Iapu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Iapu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Ibpu:
    name: Ibpu
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ibpu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Ibpu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Icpu:
    name: Icpu
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Icpu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Icpu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  value_Circuit_V_A:
    name: value_Circuit_V_A
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Circuit_V_A
    description: 'CHECKPOINT_VAR: value holder for voltage values - element 0'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Circuit_V_B:
    name: value_Circuit_V_B
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Circuit_V_B
    description: 'CHECKPOINT_VAR: value holder for voltage values - element 1'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Circuit_V_C:
    name: value_Circuit_V_C
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Circuit_V_C
    description: 'CHECKPOINT_VAR: value holder for voltage values - element 2'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Line_I_A:
    name: value_Line_I_A
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Line_I_A
    description: 'CHECKPOINT_VAR: value holder for current values - element 0'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Line_I_B:
    name: value_Line_I_B
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Line_I_B
    description: 'CHECKPOINT_VAR: value holder for current values - element 1'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Line_I_C:
    name: value_Line_I_C
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Line_I_C
    description: 'CHECKPOINT_VAR: value holder for current values - element 2'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Line12:
    name: value_Line12
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Line12
    description: 'CHECKPOINT_VAR: value holder for line current 12 in triplex metering'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  prev_current_A:
    name: prev_current_A
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_current_A
    description: 'CHECKPOINT_VAR: internal variable for prev_current[0]'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  prev_current_B:
    name: prev_current_B
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_current_B
    description: 'CHECKPOINT_VAR: internal variable for prev_current[1]'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  prev_current_C:
    name: prev_current_C
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_current_C
    description: 'CHECKPOINT_VAR: internal variable for prev_current[2]'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  NR_first_run:
    name: NR_first_run
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: NR_first_run
    description: 'CHECKPOINT_VAR: internal variable for NR_first_run'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: boolean
    required: false
  prev_current12:
    name: prev_current12
    annotations:
      order:
        tag: order
        value: 93
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_current12
    description: 'CHECKPOINT_VAR: internal variable for prev_current12'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 94
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    description: Specifies which phases to connect to - currently triplex mode is
      only supported for power curve implementation
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false

Induced

name: windturb_dg
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file windturb_dg.cpp

  @defgroup windturb_dg Wind Turbine gensets

  @ingroup generators


  Inherits from: gld_object


  Type: Instance (network topology element)


  Note: Inherits from gld_object (not in generators module)'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
  it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: glm_object
attributes:
  Gen_status:
    name: Gen_status
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Gen_status
    description: 'COP: Generator is currently available to supply power'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: string
    required: false
  Gen_type:
    name: Gen_type
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Gen_type
    description: 'COP: Standard synchronous generator; is also used to ''fake'' a
      doubly-fed induction generator for now'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - diesel_dg
    - windturb_dg
    range: GenType
    required: false
  Gen_mode:
    name: Gen_mode
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Gen_mode
    description: 'COP: Maintains the real and reactive output at the terminals - currently
      unsupported'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: string
    required: false
  Turbine_Model:
    name: Turbine_Model
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Turbine_Model
    description: Generic model for a 1.5MW turbine, power curve implementation
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: string
    required: false
  Turbine_implementation:
    name: Turbine_implementation
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Turbine_implementation
    description: Wind turbine implementation based on Generic Power Curve
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: string
    required: false
  Wind_speed_source:
    name: Wind_speed_source
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: Wind_speed_source
    description: The climate data specifying the wind speed
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: string
    required: false
  turbine_height:
    name: turbine_height
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: turbine_height[m]
    description: Describes the height of the wind turbine hub above the ground
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m
  roughness_length_factor:
    name: roughness_length_factor
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: roughness_length_factor
    description: European Wind Atlas unitless correction factor for adjusting wind
      speed at various heights above ground and terrain types, default=0.055
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
  blade_diam:
    name: blade_diam
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: blade_diam[m]
    description: 'COP: Diameter of blades'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m
  blade_diameter:
    name: blade_diameter
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: blade_diameter[m]
    description: 'COP: Diameter of blades'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m
  cut_in_ws:
    name: cut_in_ws
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: cut_in_ws[m/s]
    description: 'COP: Minimum wind speed for generator operation'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  cut_out_ws:
    name: cut_out_ws
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: cut_out_ws[m/s]
    description: 'COP: Maximum wind speed for generator operation'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  ws_rated:
    name: ws_rated
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ws_rated[m/s]
    description: 'COP: Rated wind speed for generator operation'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  ws_maxcp:
    name: ws_maxcp
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ws_maxcp[m/s]
    description: 'COP: Wind speed at which generator reaches maximum Cp'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  Cp_max:
    name: Cp_max
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Cp_max[pu]
    description: 'COP: Maximum coefficient of performance'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  Cp_rated:
    name: Cp_rated
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Cp_rated[pu]
    description: 'COP: Rated coefficient of performance'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  Cp:
    name: Cp
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Cp[pu]
    description: 'COP: Calculated coefficient of performance'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  Rated_VA:
    name: Rated_VA
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rated_VA[VA]
    description: Rated generator power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - diesel_dg
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: VA
  Rated_V:
    name: Rated_V
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rated_V[V]
    description: 'COP: Rated generator terminal voltage'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - diesel_dg
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: V
  Pconv:
    name: Pconv
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pconv[W]
    description: 'COP: Amount of electrical power converted from mechanical power
      delivered'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: W
  P_converted:
    name: P_converted
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: P_converted[W]
    description: 'COP: Amount of electrical power converted from mechanical power
      delivered'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: W
  GenElecEff:
    name: GenElecEff
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GenElecEff[%]
    description: 'COP: Calculated generator electrical efficiency'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: '%'
  generator_efficiency:
    name: generator_efficiency
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: generator_efficiency[%]
    description: 'COP: Calculated generator electrical efficiency'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: '%'
  TotalRealPow:
    name: TotalRealPow
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: TotalRealPow[W]
    description: Total real power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: W
  total_real_power:
    name: total_real_power
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: total_real_power[W]
    description: Total real power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: W
  TotalReacPow:
    name: TotalReacPow
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: TotalReacPow[VA]
    description: Total reactive power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: VA
  total_reactive_power:
    name: total_reactive_power
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: total_reactive_power[VA]
    description: Total reactive power output
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: VA
  power_A:
    name: power_A
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_A[VA]
    description: Total complex power injected on phase A
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_B:
    name: power_B
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_B[VA]
    description: Total complex power injected on phase B
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_C:
    name: power_C
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_C[VA]
    description: Total complex power injected on phase C
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_12:
    name: power_12
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_12[VA]
    description: Triplex mode - Total complex power on line 1 and 2
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  WSadj:
    name: WSadj
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: WSadj[m/s]
    description: Speed of wind at hub height
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  wind_speed_adjusted:
    name: wind_speed_adjusted
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wind_speed_adjusted[m/s]
    description: Speed of wind at hub height
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  Wind_Speed:
    name: Wind_Speed
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Wind_Speed[m/s]
    description: Wind speed at 5-15m level (typical measurement height)
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  wind_speed:
    name: wind_speed
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wind_speed[m/s]
    description: Wind speed at 5-15m level (typical measurement height)
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - solar
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  air_density:
    name: air_density
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: air_density[kg/m^3]
    description: 'COP: Estimated air density'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: kg/m^3
  wind_speed_hub_ht:
    name: wind_speed_hub_ht
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wind_speed_hub_ht[m/s]
    description: Wind speed at hub height. This is an input
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: m/s
  R_stator:
    name: R_stator
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_stator[pu*Ohm]
    description: 'COP: Induction generator primary stator resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  X_stator:
    name: X_stator
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: X_stator[pu*Ohm]
    description: 'COP: Induction generator primary stator reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  R_rotor:
    name: R_rotor
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_rotor[pu*Ohm]
    description: 'COP: Induction generator primary rotor resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  X_rotor:
    name: X_rotor
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: X_rotor[pu*Ohm]
    description: 'COP: Induction generator primary rotor reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  R_core:
    name: R_core
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_core[pu*Ohm]
    description: 'COP: Induction generator primary core resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  X_magnetic:
    name: X_magnetic
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: X_magnetic[pu*Ohm]
    description: 'COP: Induction generator primary core reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Max_Vrotor:
    name: Max_Vrotor
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Max_Vrotor[pu*V]
    description: 'COP: Induction generator maximum induced rotor voltage in p.u.,
      e.g. 1.2'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*V
  Min_Vrotor:
    name: Min_Vrotor
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Min_Vrotor[pu*V]
    description: 'COP: Induction generator minimum induced rotor voltage in p.u.,
      e.g. 0.8'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*V
  Rs:
    name: Rs
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rs[pu*Ohm]
    description: 'COP: Synchronous generator primary stator resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - motor
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Xs:
    name: Xs
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xs[pu*Ohm]
    description: 'COP: Synchronous generator primary stator reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - motor
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Rg:
    name: Rg
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rg[pu*Ohm]
    description: 'COP: Synchronous generator grounding resistance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Xg:
    name: Xg
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xg[pu*Ohm]
    description: 'COP: Synchronous generator grounding reactance in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*Ohm
  Max_Ef:
    name: Max_Ef
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Max_Ef[pu*V]
    description: 'COP: Synchronous generator maximum induced rotor voltage in p.u.,
      e.g. 0.8'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*V
  Min_Ef:
    name: Min_Ef
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Min_Ef[pu*V]
    description: 'COP: Synchronous generator minimum induced rotor voltage in p.u.,
      e.g. 0.8'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu*V
  pf:
    name: pf
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf[pu]
    description: 'COP: Desired power factor in CONSTANTP mode (can be modified over
      time)'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  power_factor:
    name: power_factor
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_factor[pu]
    description: 'COP: Desired power factor in CONSTANTP mode (can be modified over
      time)'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - performance_motor
    - battery
    - inverter
    - windturb_dg
    - residential_enduse
    range: float
    required: false
    unit:
      ucum_code: pu
  power_curve_csv:
    name: power_curve_csv
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: power_curve_csv
    description: Name of .csv file containing user defined power curve
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: string
    required: false
  power_curve_pu:
    name: power_curve_pu
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: power_curve_pu
    description: Flag when set indicates that user provided power curve has power
      values in p.u. Defaults to false
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: boolean
    required: false
  voltage_A:
    name: voltage_A
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_A[V]
    description: Terminal voltage on phase A
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_B:
    name: voltage_B
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_B[V]
    description: Terminal voltage on phase B
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_C:
    name: voltage_C
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_C[V]
    description: Terminal voltage on phase C
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_12:
    name: voltage_12
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_12[V]
    description: Triplex mode - Voltage between line 1 and line 2
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_1N:
    name: voltage_1N
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_1N[V]
    description: Triplex mode - Voltage between line 1 and the neutral N
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_2N:
    name: voltage_2N
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_2N[V]
    description: Triplex mode - Voltage between line 2 and the neutral N
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  current_A:
    name: current_A
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_A[A]
    description: Calculated terminal current on phase A
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_B:
    name: current_B
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_B[A]
    description: Calculated terminal current on phase B
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_C:
    name: current_C
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_C[A]
    description: Calculated terminal current on phase C
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_12:
    name: current_12
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_12[A]
    description: Triplex mode - Calculated line current 12
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - triplex_node
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  EfA:
    name: EfA
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: EfA[V]
    description: 'COP: Synchronous generator induced voltage on phase A'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  EfB:
    name: EfB
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: EfB[V]
    description: 'COP: Synchronous generator induced voltage on phase B'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  EfC:
    name: EfC
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: EfC[V]
    description: 'COP: Synchronous generator induced voltage on phase C'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Vrotor_A:
    name: Vrotor_A
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vrotor_A[V]
    description: 'COP: Induction generator induced voltage on phase A in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Vrotor_B:
    name: Vrotor_B
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vrotor_B[V]
    description: 'COP: Induction generator induced voltage on phase B in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Vrotor_C:
    name: Vrotor_C
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vrotor_C[V]
    description: 'COP: Induction generator induced voltage on phase C in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Irotor_A:
    name: Irotor_A
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Irotor_A[V]
    description: 'COP: Induction generator induced current on phase A in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Irotor_B:
    name: Irotor_B
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Irotor_B[V]
    description: 'COP: Induction generator induced current on phase B in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  Irotor_C:
    name: Irotor_C
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Irotor_C[V]
    description: 'COP: Induction generator induced current on phase C in p.u.'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  internal_model_current_convergence:
    name: internal_model_current_convergence
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: internal_model_current_convergence[pu]
    description: Convergence value for internal current calculations
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: pu
  Vapu:
    name: Vapu
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vapu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Vapu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Vbpu:
    name: Vbpu
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vbpu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Vbpu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Vcpu:
    name: Vcpu
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vcpu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Vcpu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Iapu:
    name: Iapu
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Iapu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Iapu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Ibpu:
    name: Ibpu
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ibpu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Ibpu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  Icpu:
    name: Icpu
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Icpu
    description: 'CHECKPOINT_VAR: Per unit voltage and current for Induction Generator
      at terminals - Icpu'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  value_Circuit_V_A:
    name: value_Circuit_V_A
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Circuit_V_A
    description: 'CHECKPOINT_VAR: value holder for voltage values - element 0'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Circuit_V_B:
    name: value_Circuit_V_B
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Circuit_V_B
    description: 'CHECKPOINT_VAR: value holder for voltage values - element 1'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Circuit_V_C:
    name: value_Circuit_V_C
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Circuit_V_C
    description: 'CHECKPOINT_VAR: value holder for voltage values - element 2'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Line_I_A:
    name: value_Line_I_A
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Line_I_A
    description: 'CHECKPOINT_VAR: value holder for current values - element 0'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Line_I_B:
    name: value_Line_I_B
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Line_I_B
    description: 'CHECKPOINT_VAR: value holder for current values - element 1'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Line_I_C:
    name: value_Line_I_C
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Line_I_C
    description: 'CHECKPOINT_VAR: value holder for current values - element 2'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  value_Line12:
    name: value_Line12
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: value_Line12
    description: 'CHECKPOINT_VAR: value holder for line current 12 in triplex metering'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - battery
    - windturb_dg
    range: Complex
    required: false
  prev_current_A:
    name: prev_current_A
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_current_A
    description: 'CHECKPOINT_VAR: internal variable for prev_current[0]'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  prev_current_B:
    name: prev_current_B
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_current_B
    description: 'CHECKPOINT_VAR: internal variable for prev_current[1]'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  prev_current_C:
    name: prev_current_C
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_current_C
    description: 'CHECKPOINT_VAR: internal variable for prev_current[2]'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  NR_first_run:
    name: NR_first_run
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: NR_first_run
    description: 'CHECKPOINT_VAR: internal variable for NR_first_run'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: boolean
    required: false
  prev_current12:
    name: prev_current12
    annotations:
      order:
        tag: order
        value: 93
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_current12
    description: 'CHECKPOINT_VAR: internal variable for prev_current12'
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    rank: 1000
    owner: windturb_dg
    domain_of:
    - windturb_dg
    range: Complex
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 94
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    description: Specifies which phases to connect to - currently triplex mode is
      only supported for power curve implementation
    from_schema: https://gridlabd.org/schema/glm/generators/windturb_dg
    owner: windturb_dg
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: windturb_dg
    domain_of:
    - glm_object
    range: string