Skip to content

Class: Meter

Copyright (C) 2008 Battelle Memorial Institute

@file meter.cpp

@addtogroup powerflow_meter Meter

@ingroup powerflow

@note The meter object now only implements polyphase meters. For a

singlephase meter, see the triplex_meter object.

Distribution meter can be either single phase or polyphase meters.

For polyphase meters, the line voltages are nominally 277V line-to-line,

and 480V line-to-ground. The ground is not presented explicitly (it is

assumed).

Total cumulative energy, instantantenous power and peak demand are

metered.

@{

__

Inherits from: node

__

Type: Instance (network topology element)

URI: glm:Meter

 classDiagram
    class Meter
    click Meter href "../Meter/"
      Node <|-- Meter
        click Node href "../Node/"

      Meter : behaving_as_swing

      Meter : bill_day

      Meter : bill_mode

      Meter : busflags

      Meter : bustype

      Meter : condition

      Meter : current_A





        Meter --> "0..1" Complex : current_A
        click Complex href "../Complex/"



      Meter : current_AB





        Meter --> "0..1" Complex : current_AB
        click Complex href "../Complex/"



      Meter : current_AN





        Meter --> "0..1" Complex : current_AN
        click Complex href "../Complex/"



      Meter : current_B





        Meter --> "0..1" Complex : current_B
        click Complex href "../Complex/"



      Meter : current_BC





        Meter --> "0..1" Complex : current_BC
        click Complex href "../Complex/"



      Meter : current_BN





        Meter --> "0..1" Complex : current_BN
        click Complex href "../Complex/"



      Meter : current_C





        Meter --> "0..1" Complex : current_C
        click Complex href "../Complex/"



      Meter : current_CA





        Meter --> "0..1" Complex : current_CA
        click Complex href "../Complex/"



      Meter : current_CN





        Meter --> "0..1" Complex : current_CN
        click Complex href "../Complex/"



      Meter : current_inj_A





        Meter --> "0..1" Complex : current_inj_A
        click Complex href "../Complex/"



      Meter : current_inj_B





        Meter --> "0..1" Complex : current_inj_B
        click Complex href "../Complex/"



      Meter : current_inj_C





        Meter --> "0..1" Complex : current_inj_C
        click Complex href "../Complex/"



      Meter : current_uptime

      Meter : customer_interrupted

      Meter : customer_interrupted_secondary

      Meter : deltamode_full_Y_all_matrix

      Meter : deltamode_full_Y_matrix

      Meter : deltamode_generator_current_A





        Meter --> "0..1" Complex : deltamode_generator_current_A
        click Complex href "../Complex/"



      Meter : deltamode_generator_current_B





        Meter --> "0..1" Complex : deltamode_generator_current_B
        click Complex href "../Complex/"



      Meter : deltamode_generator_current_C





        Meter --> "0..1" Complex : deltamode_generator_current_C
        click Complex href "../Complex/"



      Meter : deltamode_PGenTotal





        Meter --> "0..1" Complex : deltamode_PGenTotal
        click Complex href "../Complex/"



      Meter : first_tier_energy

      Meter : first_tier_price

      Meter : flags

      Meter : frequency_measure_type

      Meter : generator_dynamic

      Meter : GFA_enable

      Meter : GFA_freq_disconnect_time

      Meter : GFA_freq_high_trip

      Meter : GFA_freq_low_trip

      Meter : GFA_reconnect_time

      Meter : GFA_status

      Meter : GFA_trip_method

      Meter : GFA_volt_disconnect_time

      Meter : GFA_volt_high_trip

      Meter : GFA_volt_low_trip

      Meter : groupid

      Meter : house_present

      Meter : in_svc

      Meter : inrush_integration_method

      Meter : latitude

      Meter : longitude

      Meter : maximum_voltage_error

      Meter : mean_repair_time

      Meter : measured_angle_A

      Meter : measured_angle_B

      Meter : measured_angle_C

      Meter : measured_avg_reactive_power_A_in_interval

      Meter : measured_avg_reactive_power_B_in_interval

      Meter : measured_avg_reactive_power_C_in_interval

      Meter : measured_avg_reactive_power_in_interval

      Meter : measured_avg_real_power_A_in_interval

      Meter : measured_avg_real_power_B_in_interval

      Meter : measured_avg_real_power_C_in_interval

      Meter : measured_avg_real_power_in_interval

      Meter : measured_avg_voltage_A_mag_in_interval

      Meter : measured_avg_voltage_AB_mag_in_interval

      Meter : measured_avg_voltage_B_mag_in_interval

      Meter : measured_avg_voltage_BC_mag_in_interval

      Meter : measured_avg_voltage_C_mag_in_interval

      Meter : measured_avg_voltage_CA_mag_in_interval

      Meter : measured_current_A





        Meter --> "0..1" Complex : measured_current_A
        click Complex href "../Complex/"



      Meter : measured_current_B





        Meter --> "0..1" Complex : measured_current_B
        click Complex href "../Complex/"



      Meter : measured_current_C





        Meter --> "0..1" Complex : measured_current_C
        click Complex href "../Complex/"



      Meter : measured_demand

      Meter : measured_energy_delta_timestep

      Meter : measured_frequency

      Meter : measured_frequency_A

      Meter : measured_frequency_B

      Meter : measured_frequency_C

      Meter : measured_power





        Meter --> "0..1" Complex : measured_power
        click Complex href "../Complex/"



      Meter : measured_power_A





        Meter --> "0..1" Complex : measured_power_A
        click Complex href "../Complex/"



      Meter : measured_power_B





        Meter --> "0..1" Complex : measured_power_B
        click Complex href "../Complex/"



      Meter : measured_power_C





        Meter --> "0..1" Complex : measured_power_C
        click Complex href "../Complex/"



      Meter : measured_reactive_energy

      Meter : measured_reactive_energy_delta

      Meter : measured_reactive_max_power_A_in_interval

      Meter : measured_reactive_max_power_B_in_interval

      Meter : measured_reactive_max_power_C_in_interval

      Meter : measured_reactive_max_power_in_interval

      Meter : measured_reactive_max_voltage_A_in_interval

      Meter : measured_reactive_max_voltage_AB_in_interval

      Meter : measured_reactive_max_voltage_B_in_interval

      Meter : measured_reactive_max_voltage_BC_in_interval

      Meter : measured_reactive_max_voltage_C_in_interval

      Meter : measured_reactive_max_voltage_CA_in_interval

      Meter : measured_reactive_min_power_A_in_interval

      Meter : measured_reactive_min_power_B_in_interval

      Meter : measured_reactive_min_power_C_in_interval

      Meter : measured_reactive_min_power_in_interval

      Meter : measured_reactive_min_voltage_A_in_interval

      Meter : measured_reactive_min_voltage_AB_in_interval

      Meter : measured_reactive_min_voltage_B_in_interval

      Meter : measured_reactive_min_voltage_BC_in_interval

      Meter : measured_reactive_min_voltage_C_in_interval

      Meter : measured_reactive_min_voltage_CA_in_interval

      Meter : measured_reactive_power

      Meter : measured_real_energy

      Meter : measured_real_energy_delta

      Meter : measured_real_max_power_A_in_interval

      Meter : measured_real_max_power_B_in_interval

      Meter : measured_real_max_power_C_in_interval

      Meter : measured_real_max_power_in_interval

      Meter : measured_real_max_voltage_A_in_interval

      Meter : measured_real_max_voltage_AB_in_interval

      Meter : measured_real_max_voltage_B_in_interval

      Meter : measured_real_max_voltage_BC_in_interval

      Meter : measured_real_max_voltage_C_in_interval

      Meter : measured_real_max_voltage_CA_in_interval

      Meter : measured_real_min_power_A_in_interval

      Meter : measured_real_min_power_B_in_interval

      Meter : measured_real_min_power_C_in_interval

      Meter : measured_real_min_power_in_interval

      Meter : measured_real_min_voltage_A_in_interval

      Meter : measured_real_min_voltage_AB_in_interval

      Meter : measured_real_min_voltage_B_in_interval

      Meter : measured_real_min_voltage_BC_in_interval

      Meter : measured_real_min_voltage_C_in_interval

      Meter : measured_real_min_voltage_CA_in_interval

      Meter : measured_real_power

      Meter : measured_stats_interval

      Meter : measured_voltage_A





        Meter --> "0..1" Complex : measured_voltage_A
        click Complex href "../Complex/"



      Meter : measured_voltage_AB





        Meter --> "0..1" Complex : measured_voltage_AB
        click Complex href "../Complex/"



      Meter : measured_voltage_B





        Meter --> "0..1" Complex : measured_voltage_B
        click Complex href "../Complex/"



      Meter : measured_voltage_BC





        Meter --> "0..1" Complex : measured_voltage_BC
        click Complex href "../Complex/"



      Meter : measured_voltage_C





        Meter --> "0..1" Complex : measured_voltage_C
        click Complex href "../Complex/"



      Meter : measured_voltage_CA





        Meter --> "0..1" Complex : measured_voltage_CA
        click Complex href "../Complex/"



      Meter : meter_power_consumption





        Meter --> "0..1" Complex : meter_power_consumption
        click Complex href "../Complex/"



      Meter : momentary_count

      Meter : monthly_bill

      Meter : monthly_energy

      Meter : monthly_fee

      Meter : name

      Meter : nominal_voltage

      Meter : Norton_dynamic

      Meter : Norton_dynamic_child

      Meter : NR_powerflow_parent

      Meter : out_svc

      Meter : parent

      Meter : phases

      Meter : pll_Ki

      Meter : pll_Kp

      Meter : power_A





        Meter --> "0..1" Complex : power_A
        click Complex href "../Complex/"



      Meter : power_AB





        Meter --> "0..1" Complex : power_AB
        click Complex href "../Complex/"



      Meter : power_AN





        Meter --> "0..1" Complex : power_AN
        click Complex href "../Complex/"



      Meter : power_B





        Meter --> "0..1" Complex : power_B
        click Complex href "../Complex/"



      Meter : power_BC





        Meter --> "0..1" Complex : power_BC
        click Complex href "../Complex/"



      Meter : power_BN





        Meter --> "0..1" Complex : power_BN
        click Complex href "../Complex/"



      Meter : power_C





        Meter --> "0..1" Complex : power_C
        click Complex href "../Complex/"



      Meter : power_CA





        Meter --> "0..1" Complex : power_CA
        click Complex href "../Complex/"



      Meter : power_CN





        Meter --> "0..1" Complex : power_CN
        click Complex href "../Complex/"



      Meter : power_market

      Meter : pre_load





        Meter --> "0..1" Complex : pre_load
        click Complex href "../Complex/"



      Meter : prerotated_current_A





        Meter --> "0..1" Complex : prerotated_current_A
        click Complex href "../Complex/"



      Meter : prerotated_current_B





        Meter --> "0..1" Complex : prerotated_current_B
        click Complex href "../Complex/"



      Meter : prerotated_current_C





        Meter --> "0..1" Complex : prerotated_current_C
        click Complex href "../Complex/"



      Meter : previous_monthly_bill

      Meter : previous_monthly_energy

      Meter : previous_uptime

      Meter : price

      Meter : price_base

      Meter : rank

      Meter : reference_bus

      Meter : reset_disabled_island_state

      Meter : residential_nominal_current_A





        Meter --> "0..1" Complex : residential_nominal_current_A
        click Complex href "../Complex/"



      Meter : residential_nominal_current_A_imag

      Meter : residential_nominal_current_A_real

      Meter : residential_nominal_current_B





        Meter --> "0..1" Complex : residential_nominal_current_B
        click Complex href "../Complex/"



      Meter : residential_nominal_current_B_imag

      Meter : residential_nominal_current_B_real

      Meter : residential_nominal_current_C





        Meter --> "0..1" Complex : residential_nominal_current_C
        click Complex href "../Complex/"



      Meter : residential_nominal_current_C_imag

      Meter : residential_nominal_current_C_real

      Meter : s_flag

      Meter : second_tier_energy

      Meter : second_tier_price

      Meter : service_status

      Meter : service_status_double

      Meter : sfm_Tf

      Meter : shunt_A





        Meter --> "0..1" Complex : shunt_A
        click Complex href "../Complex/"



      Meter : shunt_AB





        Meter --> "0..1" Complex : shunt_AB
        click Complex href "../Complex/"



      Meter : shunt_AN





        Meter --> "0..1" Complex : shunt_AN
        click Complex href "../Complex/"



      Meter : shunt_B





        Meter --> "0..1" Complex : shunt_B
        click Complex href "../Complex/"



      Meter : shunt_BC





        Meter --> "0..1" Complex : shunt_BC
        click Complex href "../Complex/"



      Meter : shunt_BN





        Meter --> "0..1" Complex : shunt_BN
        click Complex href "../Complex/"



      Meter : shunt_C





        Meter --> "0..1" Complex : shunt_C
        click Complex href "../Complex/"



      Meter : shunt_CA





        Meter --> "0..1" Complex : shunt_CA
        click Complex href "../Complex/"



      Meter : shunt_CN





        Meter --> "0..1" Complex : shunt_CN
        click Complex href "../Complex/"



      Meter : solution

      Meter : sustained_count

      Meter : t_flag

      Meter : third_tier_energy

      Meter : third_tier_price

      Meter : topological_parent

      Meter : total_count

      Meter : voltage_A





        Meter --> "0..1" Complex : voltage_A
        click Complex href "../Complex/"



      Meter : voltage_AB





        Meter --> "0..1" Complex : voltage_AB
        click Complex href "../Complex/"



      Meter : voltage_B





        Meter --> "0..1" Complex : voltage_B
        click Complex href "../Complex/"



      Meter : voltage_BC





        Meter --> "0..1" Complex : voltage_BC
        click Complex href "../Complex/"



      Meter : voltage_C





        Meter --> "0..1" Complex : voltage_C
        click Complex href "../Complex/"



      Meter : voltage_CA





        Meter --> "0..1" Complex : voltage_CA
        click Complex href "../Complex/"



Inheritance

Slots

Name Cardinality and Range Description Inheritance
measured_real_energy 0..1
Float
metered real energy consumption, cummalitive direct
measured_real_energy_delta 0..1
Float
delta in metered real energy consumption from last specified measured_energy_... direct
measured_reactive_energy 0..1
Float
metered reactive energy consumption, cummalitive direct
measured_reactive_energy_delta 0..1
Float
delta in metered reactive energy consumption from last specified measured_ene... direct
measured_energy_delta_timestep 0..1
Float
Period of timestep for real and reactive delta energy calculation direct
measured_power 0..1
Complex
metered complex power direct
measured_power_A 0..1
Complex
metered complex power on phase A direct
measured_power_B 0..1
Complex
metered complex power on phase B direct
measured_power_C 0..1
Complex
metered complex power on phase C direct
measured_demand 0..1
Float
greatest metered real power during simulation direct
measured_real_power 0..1
Float
metered real power direct
measured_reactive_power 0..1
Float
metered reactive power direct
meter_power_consumption 0..1
Complex
metered power used for operating the meter; standby and communication losses direct
measured_voltage_A 0..1
Complex
measured line-to-neutral voltage on phase A direct
measured_voltage_B 0..1
Complex
measured line-to-neutral voltage on phase B direct
measured_voltage_C 0..1
Complex
measured line-to-neutral voltage on phase C direct
measured_voltage_AB 0..1
Complex
measured line-to-line voltage on phase AB direct
measured_voltage_BC 0..1
Complex
measured line-to-line voltage on phase BC direct
measured_voltage_CA 0..1
Complex
measured line-to-line voltage on phase CA direct
measured_real_max_voltage_A_in_interval 0..1
Float
measured real max line-to-neutral voltage on phase A over a specified interva... direct
measured_real_max_voltage_B_in_interval 0..1
Float
measured real max line-to-neutral voltage on phase B over a specified interva... direct
measured_real_max_voltage_C_in_interval 0..1
Float
measured real max line-to-neutral voltage on phase C over a specified interva... direct
measured_reactive_max_voltage_A_in_interval 0..1
Float
measured reactive max line-to-neutral voltage on phase A over a specified int... direct
measured_reactive_max_voltage_B_in_interval 0..1
Float
measured reactive max line-to-neutral voltage on phase B over a specified int... direct
measured_reactive_max_voltage_C_in_interval 0..1
Float
measured reactive max line-to-neutral voltage on phase C over a specified int... direct
measured_real_max_voltage_AB_in_interval 0..1
Float
measured real max line-to-line voltage on phase A over a specified interval direct
measured_real_max_voltage_BC_in_interval 0..1
Float
measured real max line-to-line voltage on phase B over a specified interval direct
measured_real_max_voltage_CA_in_interval 0..1
Float
measured real max line-to-line voltage on phase C over a specified interval direct
measured_reactive_max_voltage_AB_in_interval 0..1
Float
measured reactive max line-to-line voltage on phase A over a specified interv... direct
measured_reactive_max_voltage_BC_in_interval 0..1
Float
measured reactive max line-to-line voltage on phase B over a specified interv... direct
measured_reactive_max_voltage_CA_in_interval 0..1
Float
measured reactive max line-to-line voltage on phase C over a specified interv... direct
measured_real_min_voltage_A_in_interval 0..1
Float
measured real min line-to-neutral voltage on phase A over a specified interva... direct
measured_real_min_voltage_B_in_interval 0..1
Float
measured real min line-to-neutral voltage on phase B over a specified interva... direct
measured_real_min_voltage_C_in_interval 0..1
Float
measured real min line-to-neutral voltage on phase C over a specified interva... direct
measured_reactive_min_voltage_A_in_interval 0..1
Float
measured reactive min line-to-neutral voltage on phase A over a specified int... direct
measured_reactive_min_voltage_B_in_interval 0..1
Float
measured reactive min line-to-neutral voltage on phase B over a specified int... direct
measured_reactive_min_voltage_C_in_interval 0..1
Float
measured reactive min line-to-neutral voltage on phase C over a specified int... direct
measured_real_min_voltage_AB_in_interval 0..1
Float
measured real min line-to-line voltage on phase A over a specified interval direct
measured_real_min_voltage_BC_in_interval 0..1
Float
measured real min line-to-line voltage on phase B over a specified interval direct
measured_real_min_voltage_CA_in_interval 0..1
Float
measured real min line-to-line voltage on phase C over a specified interval direct
measured_reactive_min_voltage_AB_in_interval 0..1
Float
measured reactive min line-to-line voltage on phase A over a specified interv... direct
measured_reactive_min_voltage_BC_in_interval 0..1
Float
measured reactive min line-to-line voltage on phase B over a specified interv... direct
measured_reactive_min_voltage_CA_in_interval 0..1
Float
measured reactive min line-to-line voltage on phase C over a specified interv... direct
measured_avg_voltage_A_mag_in_interval 0..1
Float
measured avg line-to-neutral voltage magnitude on phase A over a specified in... direct
measured_avg_voltage_B_mag_in_interval 0..1
Float
measured avg line-to-neutral voltage magnitude on phase B over a specified in... direct
measured_avg_voltage_C_mag_in_interval 0..1
Float
measured avg line-to-neutral voltage magnitude on phase C over a specified in... direct
measured_avg_voltage_AB_mag_in_interval 0..1
Float
measured avg line-to-line voltage magnitude on phase A over a specified inter... direct
measured_avg_voltage_BC_mag_in_interval 0..1
Float
measured avg line-to-line voltage magnitude on phase B over a specified inter... direct
measured_avg_voltage_CA_mag_in_interval 0..1
Float
measured avg line-to-line voltage magnitude on phase C over a specified inter... direct
measured_real_max_power_in_interval 0..1
Float
measured maximum real power over a specified interval direct
measured_reactive_max_power_in_interval 0..1
Float
measured maximum reactive power over a specified interval direct
measured_real_min_power_in_interval 0..1
Float
measured minimum real power over a specified interval direct
measured_reactive_min_power_in_interval 0..1
Float
measured minimum reactive power over a specified interval direct
measured_avg_real_power_in_interval 0..1
Float
measured average real power over a specified interval direct
measured_avg_reactive_power_in_interval 0..1
Float
measured average reactive power over a specified interval direct
measured_real_max_power_A_in_interval 0..1
Float
measured A phase maximum real power over a specified interval direct
measured_reactive_max_power_A_in_interval 0..1
Float
measured A phase maximum reactive power over a specified interval direct
measured_real_min_power_A_in_interval 0..1
Float
measured A phase minimum real power over a specified interval direct
measured_reactive_min_power_A_in_interval 0..1
Float
measured A phase minimum reactive power over a specified interval direct
measured_avg_real_power_A_in_interval 0..1
Float
measured A phase average real power over a specified interval direct
measured_avg_reactive_power_A_in_interval 0..1
Float
measured A phase average reactive power over a specified interval direct
measured_real_max_power_B_in_interval 0..1
Float
measured B phase maximum real power over a specified interval direct
measured_reactive_max_power_B_in_interval 0..1
Float
measured B phase maximum reactive power over a specified interval direct
measured_real_min_power_B_in_interval 0..1
Float
measured B phase minimum real power over a specified interval direct
measured_reactive_min_power_B_in_interval 0..1
Float
measured B phase minimum reactive power over a specified interval direct
measured_avg_real_power_B_in_interval 0..1
Float
measured B phase average real power over a specified interval direct
measured_avg_reactive_power_B_in_interval 0..1
Float
measured B phase average reactive power over a specified interval direct
measured_real_max_power_C_in_interval 0..1
Float
measured C phase maximum real power over a specified interval direct
measured_reactive_max_power_C_in_interval 0..1
Float
measured C phase maximum reactive power over a specified interval direct
measured_real_min_power_C_in_interval 0..1
Float
measured C phase minimum real power over a specified interval direct
measured_reactive_min_power_C_in_interval 0..1
Float
measured C phase minimum reactive power over a specified interval direct
measured_avg_real_power_C_in_interval 0..1
Float
measured C phase average real power over a specified interval direct
measured_avg_reactive_power_C_in_interval 0..1
Float
measured C phase average reactive power over a specified interval direct
measured_stats_interval 0..1
Float
Period of timestep for min/max/average calculations direct
measured_current_A 0..1
Complex
measured current on phase A direct
measured_current_B 0..1
Complex
measured current on phase B direct
measured_current_C 0..1
Complex
measured current on phase C direct
customer_interrupted 0..1
Boolean
Reliability flag - goes active if the customer is in an 'interrupted' state direct
customer_interrupted_secondary 0..1
Boolean
Reliability flag - goes active if the customer is in an 'secondary interrupte... direct
sustained_count 0..1
Integer
direct
momentary_count 0..1
Integer
direct
total_count 0..1
Integer
direct
s_flag 0..1
Integer
direct
t_flag 0..1
Integer
direct
pre_load 0..1
Complex
direct
monthly_bill 0..1
Float
Accumulator for the current month's bill direct
previous_monthly_bill 0..1
Float
Total monthly bill for the previous month direct
previous_monthly_energy 0..1
Float
Total monthly energy for the previous month direct
monthly_fee 0..1
Float
Once a month flat fee for customer hook-up direct
monthly_energy 0..1
Float
Accumulator for the current month's energy consumption direct
bill_mode 0..1
String
Billing structure desired direct
power_market 0..1
String
Market (auction object) where the price is being received from direct
bill_day 0..1
Integer
day of month bill is to be processed (currently limited to days 1-28) direct
price 0..1
Float
current price of electricity direct
price_base 0..1
Float
Used only in TIERED_RTP mode to describe the price before the first tier direct
first_tier_price 0..1
Float
price of electricity between first tier and second tier energy usage direct
first_tier_energy 0..1
Float
switching point between base price and first tier price direct
second_tier_price 0..1
Float
price of electricity between second tier and third tier energy usage direct
second_tier_energy 0..1
Float
switching point between first tier price and second tier price direct
third_tier_price 0..1
Float
price of electricity when energy usage exceeds third tier energy usage direct
third_tier_energy 0..1
Float
switching point between second tier price and third tier price direct
bustype 0..1
String
defines whether the node is a PQ, PV, or SWING node Node
busflags 0..1
String
flag indicates node has a source for voltage, i Node
reference_bus 0..1
String
reference bus from which frequency is defined Node
maximum_voltage_error 0..1
Float
convergence voltage limit or convergence criteria Node
voltage_A 0..1
Complex
bus voltage, Phase A to ground Node
voltage_B 0..1
Complex
bus voltage, Phase B to ground Node
voltage_C 0..1
Complex
bus voltage, Phase C to ground Node
voltage_AB 0..1
Complex
line voltages, Phase AB Node
voltage_BC 0..1
Complex
line voltages, Phase BC Node
voltage_CA 0..1
Complex
line voltages, Phase CA Node
current_A 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
current_B 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
current_C 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
power_A 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
power_B 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
power_C 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
shunt_A 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
shunt_B 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
shunt_C 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
prerotated_current_A 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
prerotated_current_B 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
prerotated_current_C 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
deltamode_generator_current_A 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_generator_current_B 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_generator_current_C 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_PGenTotal 0..1
Complex
deltamode-functionality - power value for a diesel generator -- accumulator o... Node
deltamode_full_Y_matrix 0..1
String
deltamode-functionality full_Y matrix exposes so generator objects can intera... Node
deltamode_full_Y_all_matrix 0..1
String
deltamode-functionality full_Y_all matrix exposes so generator objects can in... Node
NR_powerflow_parent 0..1
String
NR powerflow - actual powerflow parent - used by generators accessing child o... Node
current_inj_A 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_inj_B 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_inj_C 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_AB 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_BC 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_CA 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_AN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
current_BN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
current_CN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
power_AB 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_BC 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_CA 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_AN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
power_BN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
power_CN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
shunt_AB 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_BC 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_CA 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_AN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
shunt_BN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
shunt_CN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
residential_nominal_current_A 0..1
Complex
posted current on phase A from a residential object, if attached Node
residential_nominal_current_B 0..1
Complex
posted current on phase B from a residential object, if attached Node
residential_nominal_current_C 0..1
Complex
posted current on phase C from a residential object, if attached Node
residential_nominal_current_A_real 0..1
Float
posted current on phase A, real, from a residential object, if attached Node
residential_nominal_current_A_imag 0..1
Float
posted current on phase A, imag, from a residential object, if attached Node
residential_nominal_current_B_real 0..1
Float
posted current on phase B, real, from a residential object, if attached Node
residential_nominal_current_B_imag 0..1
Float
posted current on phase B, imag, from a residential object, if attached Node
residential_nominal_current_C_real 0..1
Float
posted current on phase C, real, from a residential object, if attached Node
residential_nominal_current_C_imag 0..1
Float
posted current on phase C, imag, from a residential object, if attached Node
house_present 0..1
Boolean
boolean for detecting whether a house is attached, not an input Node
mean_repair_time 0..1
Float
Time after a fault clears for the object to be back in service Node
frequency_measure_type 0..1
String
PLL frequency measurement Node
sfm_Tf 0..1
Float
Transducer time constant for simplified frequency measurement (seconds) Node
pll_Kp 0..1
Float
Proportional gain of PLL frequency measurement Node
pll_Ki 0..1
Float
Integration gain of PLL frequency measurement Node
measured_angle_A 0..1
Float
bus angle measurement, phase A Node
measured_frequency_A 0..1
Float
frequency measurement, phase A Node
measured_angle_B 0..1
Float
bus angle measurement, phase B Node
measured_frequency_B 0..1
Float
frequency measurement, phase B Node
measured_angle_C 0..1
Float
bus angle measurement, phase C Node
measured_frequency_C 0..1
Float
frequency measurement, phase C Node
measured_frequency 0..1
Float
frequency measurement - average of present phases Node
service_status 0..1
String
In and out of service flag Node
service_status_double 0..1
Float
In and out of service flag - type double - will indiscriminately override ser... Node
previous_uptime 0..1
Float
Previous time between disconnects of node in minutes Node
current_uptime 0..1
Float
Current time since last disconnect of node in minutes Node
Norton_dynamic 0..1
Boolean
Flag to indicate a Norton-equivalent connection -- used for generators and de... Node
Norton_dynamic_child 0..1
Boolean
Flag to indicate a Norton-equivalent connection is made by a childed node obj... Node
generator_dynamic 0..1
Boolean
Flag to indicate a voltage-sourcing or swing-type generator is present -- use... Node
reset_disabled_island_state 0..1
Boolean
Deltamode/multi-island flag -- used to reset disabled status (and reform an i... Node
GFA_enable 0..1
Boolean
Disable/Enable Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_low_trip 0..1
Float
Low frequency trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_high_trip 0..1
Float
High frequency trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_volt_low_trip 0..1
Float
Low voltage trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_volt_high_trip 0..1
Float
High voltage trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_reconnect_time 0..1
Float
Reconnect time for Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_disconnect_time 0..1
Float
Frequency violation disconnect time for Grid Friendly Appliance(TM)-type func... Node
GFA_volt_disconnect_time 0..1
Float
Voltage violation disconnect time for Grid Friendly Appliance(TM)-type functi... Node
GFA_status 0..1
Boolean
Grid Friendly Appliance(TM)-type functionality - whether it is in service (no... Node
GFA_trip_method 0..1
String
GFA trip for over-voltage Node
topological_parent 0..1
String
topological parent as per GLM configuration Node
behaving_as_swing 0..1
Boolean
Indicator flag for if a bus is behaving as a reference voltage source - valid... Node
phases 0..1
String
PowerflowObject
nominal_voltage 0..1
Float
PowerflowObject
inrush_integration_method 0..1
String
Integration method for in-rush PowerflowObject
condition 0..1
String
PowerflowObject
solution 0..1
String
PowerflowObject
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: ConnectivityNode, mRID = name (bus.cimtbl), as a node; metering and billing slots are not converted. Export: not written; a ConnectivityNode is a node.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:Meter
native glm:Meter
exact cim:ConnectivityNode

LinkML Source

Direct

name: meter
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file meter.cpp

  @addtogroup powerflow_meter Meter

  @ingroup powerflow

  @note The meter object now only implements polyphase meters.  For a

  singlephase meter, see the triplex_meter object.

  Distribution meter can be either single phase or polyphase meters.

  For polyphase meters, the line voltages are nominally 277V line-to-line,

  and 480V line-to-ground.  The ground is not presented explicitly (it is

  assumed).

  Total cumulative energy, instantantenous power and peak demand are

  metered.

  @{


  Inherits from: node


  Type: Instance (network topology element)'
comments:
- 'Import: ConnectivityNode, mRID = name (bus.cimtbl), as a node; metering and billing
  slots are not converted. Export: not written; a ConnectivityNode is a node.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:ConnectivityNode
is_a: node
attributes:
  measured_real_energy:
    name: measured_real_energy
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_energy[Wh]
    description: metered real energy consumption, cummalitive
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: Wh
  measured_real_energy_delta:
    name: measured_real_energy_delta
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_energy_delta[Wh]
    description: delta in metered real energy consumption from last specified measured_energy_delta_timestep
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: Wh
  measured_reactive_energy:
    name: measured_reactive_energy
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_energy[VAh]
    description: metered reactive energy consumption, cummalitive
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAh
  measured_reactive_energy_delta:
    name: measured_reactive_energy_delta
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_energy_delta[VAh]
    description: delta in metered reactive energy consumption from last specified
      measured_energy_delta_timestep
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAh
  measured_energy_delta_timestep:
    name: measured_energy_delta_timestep
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_energy_delta_timestep[s]
    description: Period of timestep for real and reactive delta energy calculation
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: s
  measured_power:
    name: measured_power
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power[VA]
    description: metered complex power
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power_A:
    name: measured_power_A
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_A[VA]
    description: metered complex power on phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power_B:
    name: measured_power_B
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_B[VA]
    description: metered complex power on phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power_C:
    name: measured_power_C
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_C[VA]
    description: metered complex power on phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_demand:
    name: measured_demand
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_demand[W]
    description: greatest metered real power during simulation
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_real_power:
    name: measured_real_power
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_power[W]
    description: metered real power
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_power:
    name: measured_reactive_power
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_power[VAr]
    description: metered reactive power
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  meter_power_consumption:
    name: meter_power_consumption
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: meter_power_consumption[VA]
    description: metered power used for operating the meter; standby and communication
      losses
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_voltage_A:
    name: measured_voltage_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_A[V]
    description: measured line-to-neutral voltage on phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_B:
    name: measured_voltage_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_B[V]
    description: measured line-to-neutral voltage on phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_C:
    name: measured_voltage_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_C[V]
    description: measured line-to-neutral voltage on phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_AB:
    name: measured_voltage_AB
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_AB[V]
    description: measured line-to-line voltage on phase AB
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_BC:
    name: measured_voltage_BC
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_BC[V]
    description: measured line-to-line voltage on phase BC
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_CA:
    name: measured_voltage_CA
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_CA[V]
    description: measured line-to-line voltage on phase CA
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_A_in_interval:
    name: measured_real_max_voltage_A_in_interval
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_A_in_interval[V]
    description: measured real max line-to-neutral voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_B_in_interval:
    name: measured_real_max_voltage_B_in_interval
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_B_in_interval[V]
    description: measured real max line-to-neutral voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_C_in_interval:
    name: measured_real_max_voltage_C_in_interval
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_C_in_interval[V]
    description: measured real max line-to-neutral voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_A_in_interval:
    name: measured_reactive_max_voltage_A_in_interval
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_A_in_interval[V]
    description: measured reactive max line-to-neutral voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_B_in_interval:
    name: measured_reactive_max_voltage_B_in_interval
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_B_in_interval[V]
    description: measured reactive max line-to-neutral voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_C_in_interval:
    name: measured_reactive_max_voltage_C_in_interval
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_C_in_interval[V]
    description: measured reactive max line-to-neutral voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_AB_in_interval:
    name: measured_real_max_voltage_AB_in_interval
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_AB_in_interval[V]
    description: measured real max line-to-line voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_BC_in_interval:
    name: measured_real_max_voltage_BC_in_interval
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_BC_in_interval[V]
    description: measured real max line-to-line voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_CA_in_interval:
    name: measured_real_max_voltage_CA_in_interval
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_CA_in_interval[V]
    description: measured real max line-to-line voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_AB_in_interval:
    name: measured_reactive_max_voltage_AB_in_interval
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_AB_in_interval[V]
    description: measured reactive max line-to-line voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_BC_in_interval:
    name: measured_reactive_max_voltage_BC_in_interval
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_BC_in_interval[V]
    description: measured reactive max line-to-line voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_CA_in_interval:
    name: measured_reactive_max_voltage_CA_in_interval
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_CA_in_interval[V]
    description: measured reactive max line-to-line voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_A_in_interval:
    name: measured_real_min_voltage_A_in_interval
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_A_in_interval[V]
    description: measured real min line-to-neutral voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_B_in_interval:
    name: measured_real_min_voltage_B_in_interval
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_B_in_interval[V]
    description: measured real min line-to-neutral voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_C_in_interval:
    name: measured_real_min_voltage_C_in_interval
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_C_in_interval[V]
    description: measured real min line-to-neutral voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_A_in_interval:
    name: measured_reactive_min_voltage_A_in_interval
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_A_in_interval[V]
    description: measured reactive min line-to-neutral voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_B_in_interval:
    name: measured_reactive_min_voltage_B_in_interval
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_B_in_interval[V]
    description: measured reactive min line-to-neutral voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_C_in_interval:
    name: measured_reactive_min_voltage_C_in_interval
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_C_in_interval[V]
    description: measured reactive min line-to-neutral voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_AB_in_interval:
    name: measured_real_min_voltage_AB_in_interval
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_AB_in_interval[V]
    description: measured real min line-to-line voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_BC_in_interval:
    name: measured_real_min_voltage_BC_in_interval
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_BC_in_interval[V]
    description: measured real min line-to-line voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_CA_in_interval:
    name: measured_real_min_voltage_CA_in_interval
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_CA_in_interval[V]
    description: measured real min line-to-line voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_AB_in_interval:
    name: measured_reactive_min_voltage_AB_in_interval
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_AB_in_interval[V]
    description: measured reactive min line-to-line voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_BC_in_interval:
    name: measured_reactive_min_voltage_BC_in_interval
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_BC_in_interval[V]
    description: measured reactive min line-to-line voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_CA_in_interval:
    name: measured_reactive_min_voltage_CA_in_interval
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_CA_in_interval[V]
    description: measured reactive min line-to-line voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_A_mag_in_interval:
    name: measured_avg_voltage_A_mag_in_interval
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_A_mag_in_interval[V]
    description: measured avg line-to-neutral voltage magnitude on phase A over a
      specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_B_mag_in_interval:
    name: measured_avg_voltage_B_mag_in_interval
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_B_mag_in_interval[V]
    description: measured avg line-to-neutral voltage magnitude on phase B over a
      specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_C_mag_in_interval:
    name: measured_avg_voltage_C_mag_in_interval
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_C_mag_in_interval[V]
    description: measured avg line-to-neutral voltage magnitude on phase C over a
      specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_AB_mag_in_interval:
    name: measured_avg_voltage_AB_mag_in_interval
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_AB_mag_in_interval[V]
    description: measured avg line-to-line voltage magnitude on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_BC_mag_in_interval:
    name: measured_avg_voltage_BC_mag_in_interval
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_BC_mag_in_interval[V]
    description: measured avg line-to-line voltage magnitude on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_CA_mag_in_interval:
    name: measured_avg_voltage_CA_mag_in_interval
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_CA_mag_in_interval[V]
    description: measured avg line-to-line voltage magnitude on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_power_in_interval:
    name: measured_real_max_power_in_interval
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_power_in_interval[W]
    description: measured maximum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_max_power_in_interval:
    name: measured_reactive_max_power_in_interval
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_power_in_interval[VAr]
    description: measured maximum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_min_power_in_interval:
    name: measured_real_min_power_in_interval
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_power_in_interval[W]
    description: measured minimum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_min_power_in_interval:
    name: measured_reactive_min_power_in_interval
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_power_in_interval[VAr]
    description: measured minimum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_avg_real_power_in_interval:
    name: measured_avg_real_power_in_interval
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_real_power_in_interval[W]
    description: measured average real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_avg_reactive_power_in_interval:
    name: measured_avg_reactive_power_in_interval
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_reactive_power_in_interval[VAr]
    description: measured average reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_max_power_A_in_interval:
    name: measured_real_max_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_power_A_in_interval[W]
    description: measured A phase maximum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_max_power_A_in_interval:
    name: measured_reactive_max_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_power_A_in_interval[VAr]
    description: measured A phase maximum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_min_power_A_in_interval:
    name: measured_real_min_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_power_A_in_interval[W]
    description: measured A phase minimum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_min_power_A_in_interval:
    name: measured_reactive_min_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_power_A_in_interval[VAr]
    description: measured A phase minimum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_avg_real_power_A_in_interval:
    name: measured_avg_real_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_real_power_A_in_interval[W]
    description: measured A phase average real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_avg_reactive_power_A_in_interval:
    name: measured_avg_reactive_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_reactive_power_A_in_interval[VAr]
    description: measured A phase average reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_max_power_B_in_interval:
    name: measured_real_max_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_power_B_in_interval[W]
    description: measured B phase maximum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_max_power_B_in_interval:
    name: measured_reactive_max_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_power_B_in_interval[VAr]
    description: measured B phase maximum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_min_power_B_in_interval:
    name: measured_real_min_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_power_B_in_interval[W]
    description: measured B phase minimum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_min_power_B_in_interval:
    name: measured_reactive_min_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_power_B_in_interval[VAr]
    description: measured B phase minimum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_avg_real_power_B_in_interval:
    name: measured_avg_real_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_real_power_B_in_interval[W]
    description: measured B phase average real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_avg_reactive_power_B_in_interval:
    name: measured_avg_reactive_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_reactive_power_B_in_interval[VAr]
    description: measured B phase average reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_max_power_C_in_interval:
    name: measured_real_max_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_power_C_in_interval[W]
    description: measured C phase maximum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_max_power_C_in_interval:
    name: measured_reactive_max_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_power_C_in_interval[VAr]
    description: measured C phase maximum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_min_power_C_in_interval:
    name: measured_real_min_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_power_C_in_interval[W]
    description: measured C phase minimum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_min_power_C_in_interval:
    name: measured_reactive_min_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_power_C_in_interval[VAr]
    description: measured C phase minimum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_avg_real_power_C_in_interval:
    name: measured_avg_real_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_real_power_C_in_interval[W]
    description: measured C phase average real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_avg_reactive_power_C_in_interval:
    name: measured_avg_reactive_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_reactive_power_C_in_interval[VAr]
    description: measured C phase average reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_stats_interval:
    name: measured_stats_interval
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_stats_interval[s]
    description: Period of timestep for min/max/average calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: s
  measured_current_A:
    name: measured_current_A
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_current_A[A]
    description: measured current on phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: A
  measured_current_B:
    name: measured_current_B
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_current_B[A]
    description: measured current on phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: A
  measured_current_C:
    name: measured_current_C
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_current_C[A]
    description: measured current on phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: A
  customer_interrupted:
    name: customer_interrupted
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: customer_interrupted
    description: Reliability flag - goes active if the customer is in an 'interrupted'
      state
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: boolean
    required: false
  customer_interrupted_secondary:
    name: customer_interrupted_secondary
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: customer_interrupted_secondary
    description: Reliability flag - goes active if the customer is in an 'secondary
      interrupted' state - i.e., momentary
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: boolean
    required: false
  sustained_count:
    name: sustained_count
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: sustained_count
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  momentary_count:
    name: momentary_count
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: momentary_count
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  total_count:
    name: total_count
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: total_count
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  s_flag:
    name: s_flag
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: s_flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  t_flag:
    name: t_flag
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: t_flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  pre_load:
    name: pre_load
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: pre_load
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: Complex
    required: false
  monthly_bill:
    name: monthly_bill
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: monthly_bill[$]
    description: Accumulator for the current month's bill
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $
  previous_monthly_bill:
    name: previous_monthly_bill
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_monthly_bill[$]
    description: Total monthly bill for the previous month
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $
  previous_monthly_energy:
    name: previous_monthly_energy
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_monthly_energy[kWh]
    description: Total monthly energy for the previous month
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  monthly_fee:
    name: monthly_fee
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: monthly_fee[$]
    description: Once a month flat fee for customer hook-up
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $
  monthly_energy:
    name: monthly_energy
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: monthly_energy[kWh]
    description: Accumulator for the current month's energy consumption
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  bill_mode:
    name: bill_mode
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: bill_mode
    description: Billing structure desired
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: string
    required: false
  power_market:
    name: power_market
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: power_market
    description: Market (auction object) where the price is being received from
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: string
    required: false
  bill_day:
    name: bill_day
    annotations:
      order:
        tag: order
        value: 93
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: bill_day
    description: day of month bill is to be processed (currently limited to days 1-28)
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  price:
    name: price
    annotations:
      order:
        tag: order
        value: 94
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: price[$/kWh]
    description: current price of electricity
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  price_base:
    name: price_base
    annotations:
      order:
        tag: order
        value: 95
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: price_base[$/kWh]
    description: Used only in TIERED_RTP mode to describe the price before the first
      tier
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  first_tier_price:
    name: first_tier_price
    annotations:
      order:
        tag: order
        value: 96
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: first_tier_price[$/kWh]
    description: price of electricity between first tier and second tier energy usage
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  first_tier_energy:
    name: first_tier_energy
    annotations:
      order:
        tag: order
        value: 97
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: first_tier_energy[kWh]
    description: switching point between base price and first tier price
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  second_tier_price:
    name: second_tier_price
    annotations:
      order:
        tag: order
        value: 98
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: second_tier_price[$/kWh]
    description: price of electricity between second tier and third tier energy usage
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  second_tier_energy:
    name: second_tier_energy
    annotations:
      order:
        tag: order
        value: 99
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: second_tier_energy[kWh]
    description: switching point between first tier price and second tier price
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  third_tier_price:
    name: third_tier_price
    annotations:
      order:
        tag: order
        value: 100
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: third_tier_price[$/kWh]
    description: price of electricity when energy usage exceeds third tier energy
      usage
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  third_tier_energy:
    name: third_tier_energy
    annotations:
      order:
        tag: order
        value: 101
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: third_tier_energy[kWh]
    description: switching point between second tier price and third tier price
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh

Induced

name: meter
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file meter.cpp

  @addtogroup powerflow_meter Meter

  @ingroup powerflow

  @note The meter object now only implements polyphase meters.  For a

  singlephase meter, see the triplex_meter object.

  Distribution meter can be either single phase or polyphase meters.

  For polyphase meters, the line voltages are nominally 277V line-to-line,

  and 480V line-to-ground.  The ground is not presented explicitly (it is

  assumed).

  Total cumulative energy, instantantenous power and peak demand are

  metered.

  @{


  Inherits from: node


  Type: Instance (network topology element)'
comments:
- 'Import: ConnectivityNode, mRID = name (bus.cimtbl), as a node; metering and billing
  slots are not converted. Export: not written; a ConnectivityNode is a node.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:ConnectivityNode
is_a: node
attributes:
  measured_real_energy:
    name: measured_real_energy
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_energy[Wh]
    description: metered real energy consumption, cummalitive
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: Wh
  measured_real_energy_delta:
    name: measured_real_energy_delta
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_energy_delta[Wh]
    description: delta in metered real energy consumption from last specified measured_energy_delta_timestep
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: Wh
  measured_reactive_energy:
    name: measured_reactive_energy
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_energy[VAh]
    description: metered reactive energy consumption, cummalitive
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAh
  measured_reactive_energy_delta:
    name: measured_reactive_energy_delta
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_energy_delta[VAh]
    description: delta in metered reactive energy consumption from last specified
      measured_energy_delta_timestep
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAh
  measured_energy_delta_timestep:
    name: measured_energy_delta_timestep
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_energy_delta_timestep[s]
    description: Period of timestep for real and reactive delta energy calculation
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: s
  measured_power:
    name: measured_power
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power[VA]
    description: metered complex power
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power_A:
    name: measured_power_A
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_A[VA]
    description: metered complex power on phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power_B:
    name: measured_power_B
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_B[VA]
    description: metered complex power on phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power_C:
    name: measured_power_C
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power_C[VA]
    description: metered complex power on phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_demand:
    name: measured_demand
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_demand[W]
    description: greatest metered real power during simulation
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_real_power:
    name: measured_real_power
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_power[W]
    description: metered real power
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_power:
    name: measured_reactive_power
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_power[VAr]
    description: metered reactive power
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  meter_power_consumption:
    name: meter_power_consumption
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: meter_power_consumption[VA]
    description: metered power used for operating the meter; standby and communication
      losses
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_voltage_A:
    name: measured_voltage_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_A[V]
    description: measured line-to-neutral voltage on phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_B:
    name: measured_voltage_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_B[V]
    description: measured line-to-neutral voltage on phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_C:
    name: measured_voltage_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_C[V]
    description: measured line-to-neutral voltage on phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_AB:
    name: measured_voltage_AB
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_AB[V]
    description: measured line-to-line voltage on phase AB
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_BC:
    name: measured_voltage_BC
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_BC[V]
    description: measured line-to-line voltage on phase BC
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_CA:
    name: measured_voltage_CA
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_CA[V]
    description: measured line-to-line voltage on phase CA
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    owner: meter
    domain_of:
    - load
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_A_in_interval:
    name: measured_real_max_voltage_A_in_interval
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_A_in_interval[V]
    description: measured real max line-to-neutral voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_B_in_interval:
    name: measured_real_max_voltage_B_in_interval
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_B_in_interval[V]
    description: measured real max line-to-neutral voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_C_in_interval:
    name: measured_real_max_voltage_C_in_interval
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_C_in_interval[V]
    description: measured real max line-to-neutral voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_A_in_interval:
    name: measured_reactive_max_voltage_A_in_interval
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_A_in_interval[V]
    description: measured reactive max line-to-neutral voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_B_in_interval:
    name: measured_reactive_max_voltage_B_in_interval
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_B_in_interval[V]
    description: measured reactive max line-to-neutral voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_C_in_interval:
    name: measured_reactive_max_voltage_C_in_interval
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_C_in_interval[V]
    description: measured reactive max line-to-neutral voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_AB_in_interval:
    name: measured_real_max_voltage_AB_in_interval
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_AB_in_interval[V]
    description: measured real max line-to-line voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_BC_in_interval:
    name: measured_real_max_voltage_BC_in_interval
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_BC_in_interval[V]
    description: measured real max line-to-line voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_voltage_CA_in_interval:
    name: measured_real_max_voltage_CA_in_interval
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_voltage_CA_in_interval[V]
    description: measured real max line-to-line voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_AB_in_interval:
    name: measured_reactive_max_voltage_AB_in_interval
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_AB_in_interval[V]
    description: measured reactive max line-to-line voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_BC_in_interval:
    name: measured_reactive_max_voltage_BC_in_interval
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_BC_in_interval[V]
    description: measured reactive max line-to-line voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_max_voltage_CA_in_interval:
    name: measured_reactive_max_voltage_CA_in_interval
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_voltage_CA_in_interval[V]
    description: measured reactive max line-to-line voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_A_in_interval:
    name: measured_real_min_voltage_A_in_interval
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_A_in_interval[V]
    description: measured real min line-to-neutral voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_B_in_interval:
    name: measured_real_min_voltage_B_in_interval
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_B_in_interval[V]
    description: measured real min line-to-neutral voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_C_in_interval:
    name: measured_real_min_voltage_C_in_interval
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_C_in_interval[V]
    description: measured real min line-to-neutral voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_A_in_interval:
    name: measured_reactive_min_voltage_A_in_interval
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_A_in_interval[V]
    description: measured reactive min line-to-neutral voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_B_in_interval:
    name: measured_reactive_min_voltage_B_in_interval
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_B_in_interval[V]
    description: measured reactive min line-to-neutral voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_C_in_interval:
    name: measured_reactive_min_voltage_C_in_interval
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_C_in_interval[V]
    description: measured reactive min line-to-neutral voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_AB_in_interval:
    name: measured_real_min_voltage_AB_in_interval
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_AB_in_interval[V]
    description: measured real min line-to-line voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_BC_in_interval:
    name: measured_real_min_voltage_BC_in_interval
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_BC_in_interval[V]
    description: measured real min line-to-line voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_min_voltage_CA_in_interval:
    name: measured_real_min_voltage_CA_in_interval
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_voltage_CA_in_interval[V]
    description: measured real min line-to-line voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_AB_in_interval:
    name: measured_reactive_min_voltage_AB_in_interval
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_AB_in_interval[V]
    description: measured reactive min line-to-line voltage on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_BC_in_interval:
    name: measured_reactive_min_voltage_BC_in_interval
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_BC_in_interval[V]
    description: measured reactive min line-to-line voltage on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_reactive_min_voltage_CA_in_interval:
    name: measured_reactive_min_voltage_CA_in_interval
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_voltage_CA_in_interval[V]
    description: measured reactive min line-to-line voltage on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_A_mag_in_interval:
    name: measured_avg_voltage_A_mag_in_interval
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_A_mag_in_interval[V]
    description: measured avg line-to-neutral voltage magnitude on phase A over a
      specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_B_mag_in_interval:
    name: measured_avg_voltage_B_mag_in_interval
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_B_mag_in_interval[V]
    description: measured avg line-to-neutral voltage magnitude on phase B over a
      specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_C_mag_in_interval:
    name: measured_avg_voltage_C_mag_in_interval
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_C_mag_in_interval[V]
    description: measured avg line-to-neutral voltage magnitude on phase C over a
      specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_AB_mag_in_interval:
    name: measured_avg_voltage_AB_mag_in_interval
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_AB_mag_in_interval[V]
    description: measured avg line-to-line voltage magnitude on phase A over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_BC_mag_in_interval:
    name: measured_avg_voltage_BC_mag_in_interval
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_BC_mag_in_interval[V]
    description: measured avg line-to-line voltage magnitude on phase B over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_avg_voltage_CA_mag_in_interval:
    name: measured_avg_voltage_CA_mag_in_interval
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_voltage_CA_mag_in_interval[V]
    description: measured avg line-to-line voltage magnitude on phase C over a specified
      interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: V
  measured_real_max_power_in_interval:
    name: measured_real_max_power_in_interval
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_power_in_interval[W]
    description: measured maximum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_max_power_in_interval:
    name: measured_reactive_max_power_in_interval
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_power_in_interval[VAr]
    description: measured maximum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_min_power_in_interval:
    name: measured_real_min_power_in_interval
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_power_in_interval[W]
    description: measured minimum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_min_power_in_interval:
    name: measured_reactive_min_power_in_interval
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_power_in_interval[VAr]
    description: measured minimum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_avg_real_power_in_interval:
    name: measured_avg_real_power_in_interval
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_real_power_in_interval[W]
    description: measured average real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_avg_reactive_power_in_interval:
    name: measured_avg_reactive_power_in_interval
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_reactive_power_in_interval[VAr]
    description: measured average reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_max_power_A_in_interval:
    name: measured_real_max_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_power_A_in_interval[W]
    description: measured A phase maximum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_max_power_A_in_interval:
    name: measured_reactive_max_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_power_A_in_interval[VAr]
    description: measured A phase maximum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_min_power_A_in_interval:
    name: measured_real_min_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_power_A_in_interval[W]
    description: measured A phase minimum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_min_power_A_in_interval:
    name: measured_reactive_min_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_power_A_in_interval[VAr]
    description: measured A phase minimum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_avg_real_power_A_in_interval:
    name: measured_avg_real_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_real_power_A_in_interval[W]
    description: measured A phase average real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_avg_reactive_power_A_in_interval:
    name: measured_avg_reactive_power_A_in_interval
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_reactive_power_A_in_interval[VAr]
    description: measured A phase average reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_max_power_B_in_interval:
    name: measured_real_max_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_power_B_in_interval[W]
    description: measured B phase maximum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_max_power_B_in_interval:
    name: measured_reactive_max_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_power_B_in_interval[VAr]
    description: measured B phase maximum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_min_power_B_in_interval:
    name: measured_real_min_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_power_B_in_interval[W]
    description: measured B phase minimum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_min_power_B_in_interval:
    name: measured_reactive_min_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_power_B_in_interval[VAr]
    description: measured B phase minimum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_avg_real_power_B_in_interval:
    name: measured_avg_real_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_real_power_B_in_interval[W]
    description: measured B phase average real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_avg_reactive_power_B_in_interval:
    name: measured_avg_reactive_power_B_in_interval
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_reactive_power_B_in_interval[VAr]
    description: measured B phase average reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_max_power_C_in_interval:
    name: measured_real_max_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_max_power_C_in_interval[W]
    description: measured C phase maximum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_max_power_C_in_interval:
    name: measured_reactive_max_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_max_power_C_in_interval[VAr]
    description: measured C phase maximum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_real_min_power_C_in_interval:
    name: measured_real_min_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_real_min_power_C_in_interval[W]
    description: measured C phase minimum real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_reactive_min_power_C_in_interval:
    name: measured_reactive_min_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_reactive_min_power_C_in_interval[VAr]
    description: measured C phase minimum reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_avg_real_power_C_in_interval:
    name: measured_avg_real_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_real_power_C_in_interval[W]
    description: measured C phase average real power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: W
  measured_avg_reactive_power_C_in_interval:
    name: measured_avg_reactive_power_C_in_interval
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_avg_reactive_power_C_in_interval[VAr]
    description: measured C phase average reactive power over a specified interval
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: float
    required: false
    unit:
      ucum_code: VAr
  measured_stats_interval:
    name: measured_stats_interval
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_stats_interval[s]
    description: Period of timestep for min/max/average calculations
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: s
  measured_current_A:
    name: measured_current_A
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_current_A[A]
    description: measured current on phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: A
  measured_current_B:
    name: measured_current_B
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_current_B[A]
    description: measured current on phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: A
  measured_current_C:
    name: measured_current_C
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_current_C[A]
    description: measured current on phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    range: Complex
    required: false
    unit:
      ucum_code: A
  customer_interrupted:
    name: customer_interrupted
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: customer_interrupted
    description: Reliability flag - goes active if the customer is in an 'interrupted'
      state
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: boolean
    required: false
  customer_interrupted_secondary:
    name: customer_interrupted_secondary
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: customer_interrupted_secondary
    description: Reliability flag - goes active if the customer is in an 'secondary
      interrupted' state - i.e., momentary
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: boolean
    required: false
  sustained_count:
    name: sustained_count
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: sustained_count
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  momentary_count:
    name: momentary_count
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: momentary_count
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  total_count:
    name: total_count
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: total_count
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  s_flag:
    name: s_flag
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: s_flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  t_flag:
    name: t_flag
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: t_flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  pre_load:
    name: pre_load
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: pre_load
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: Complex
    required: false
  monthly_bill:
    name: monthly_bill
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: monthly_bill[$]
    description: Accumulator for the current month's bill
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $
  previous_monthly_bill:
    name: previous_monthly_bill
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_monthly_bill[$]
    description: Total monthly bill for the previous month
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $
  previous_monthly_energy:
    name: previous_monthly_energy
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_monthly_energy[kWh]
    description: Total monthly energy for the previous month
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  monthly_fee:
    name: monthly_fee
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: monthly_fee[$]
    description: Once a month flat fee for customer hook-up
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $
  monthly_energy:
    name: monthly_energy
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: monthly_energy[kWh]
    description: Accumulator for the current month's energy consumption
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  bill_mode:
    name: bill_mode
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: bill_mode
    description: Billing structure desired
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: string
    required: false
  power_market:
    name: power_market
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: power_market
    description: Market (auction object) where the price is being received from
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: string
    required: false
  bill_day:
    name: bill_day
    annotations:
      order:
        tag: order
        value: 93
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: bill_day
    description: day of month bill is to be processed (currently limited to days 1-28)
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: integer
    required: false
  price:
    name: price
    annotations:
      order:
        tag: order
        value: 94
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: price[$/kWh]
    description: current price of electricity
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  price_base:
    name: price_base
    annotations:
      order:
        tag: order
        value: 95
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: price_base[$/kWh]
    description: Used only in TIERED_RTP mode to describe the price before the first
      tier
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  first_tier_price:
    name: first_tier_price
    annotations:
      order:
        tag: order
        value: 96
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: first_tier_price[$/kWh]
    description: price of electricity between first tier and second tier energy usage
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  first_tier_energy:
    name: first_tier_energy
    annotations:
      order:
        tag: order
        value: 97
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: first_tier_energy[kWh]
    description: switching point between base price and first tier price
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  second_tier_price:
    name: second_tier_price
    annotations:
      order:
        tag: order
        value: 98
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: second_tier_price[$/kWh]
    description: price of electricity between second tier and third tier energy usage
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  second_tier_energy:
    name: second_tier_energy
    annotations:
      order:
        tag: order
        value: 99
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: second_tier_energy[kWh]
    description: switching point between first tier price and second tier price
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  third_tier_price:
    name: third_tier_price
    annotations:
      order:
        tag: order
        value: 100
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: third_tier_price[$/kWh]
    description: price of electricity when energy usage exceeds third tier energy
      usage
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: $/kWh
  third_tier_energy:
    name: third_tier_energy
    annotations:
      order:
        tag: order
        value: 101
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: third_tier_energy[kWh]
    description: switching point between second tier price and third tier price
    from_schema: https://gridlabd.org/schema/glm/powerflow/meter
    rank: 1000
    owner: meter
    domain_of:
    - meter
    - triplex_meter
    range: float
    required: false
    unit:
      ucum_code: kWh
  bustype:
    name: bustype
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: bustype
    description: defines whether the node is a PQ, PV, or SWING node
    comments:
    - 'Import: SWING makes an EnergySource; PQ, PV and SWING_PQ are a plain bus (SWING_PQ
      is a swing only when islanded). Export: SWING on the substation only.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    related_mappings:
    - cim:EnergySource
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  busflags:
    name: busflags
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: busflags
    description: flag indicates node has a source for voltage, i.e. connects to the
      swing node
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  reference_bus:
    name: reference_bus
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reference_bus
    description: reference bus from which frequency is defined
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  maximum_voltage_error:
    name: maximum_voltage_error
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_voltage_error[V]
    description: convergence voltage limit or convergence criteria
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: V
  voltage_A:
    name: voltage_A
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_A[V]
    description: bus voltage, Phase A to ground
    comments:
    - 'Import: on a SWING bus only: EnergySource.voltageMagnitude (line to line) and
      voltageAngle (deg) from |V| and arg(V); elsewhere the solver guess, not converted.
      Export: not written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    close_mappings:
    - cim:EnergySource.voltageMagnitude
    - cim:EnergySource.voltageAngle
    rank: 1000
    owner: meter
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_B:
    name: voltage_B
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_B[V]
    description: bus voltage, Phase B to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_C:
    name: voltage_C
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_C[V]
    description: bus voltage, Phase C to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_AB:
    name: voltage_AB
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_AB[V]
    description: line voltages, Phase AB
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_BC:
    name: voltage_BC
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_BC[V]
    description: line voltages, Phase BC
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_CA:
    name: voltage_CA
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_CA[V]
    description: line voltages, Phase CA
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  current_A:
    name: current_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_A[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_B:
    name: current_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_B[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_C:
    name: current_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_C[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_A:
    name: power_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_A[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_B:
    name: power_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_B[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_C:
    name: power_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_C[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_A:
    name: shunt_A
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_A[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_B:
    name: shunt_B
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_B[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_C:
    name: shunt_C
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_C[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  prerotated_current_A:
    name: prerotated_current_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_A[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_B:
    name: prerotated_current_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_B[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_C:
    name: prerotated_current_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_C[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_A:
    name: deltamode_generator_current_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_A[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_B:
    name: deltamode_generator_current_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_B[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_C:
    name: deltamode_generator_current_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_C[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_PGenTotal:
    name: deltamode_PGenTotal
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_PGenTotal
    description: deltamode-functionality - power value for a diesel generator -- accumulator
      only, not an output or input
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: Complex
    required: false
  deltamode_full_Y_matrix:
    name: deltamode_full_Y_matrix
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_matrix
    description: deltamode-functionality full_Y matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  deltamode_full_Y_all_matrix:
    name: deltamode_full_Y_all_matrix
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_all_matrix
    description: deltamode-functionality full_Y_all matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  NR_powerflow_parent:
    name: NR_powerflow_parent
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: NR_powerflow_parent
    description: NR powerflow - actual powerflow parent - used by generators accessing
      child objects
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  current_inj_A:
    name: current_inj_A
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_A[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_inj_B:
    name: current_inj_B
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_B[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_inj_C:
    name: current_inj_C
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_C[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_AB:
    name: current_AB
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_AB[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_BC:
    name: current_BC
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_BC[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_CA:
    name: current_CA
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_CA[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_AN:
    name: current_AN
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_AN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_BN:
    name: current_BN
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_BN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_CN:
    name: current_CN
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_CN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_AB:
    name: power_AB
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_AB[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_BC:
    name: power_BC
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_BC[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_CA:
    name: power_CA
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_CA[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_AN:
    name: power_AN
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_AN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_BN:
    name: power_BN
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_BN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_CN:
    name: power_CN
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_CN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_AB:
    name: shunt_AB
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_AB[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_BC:
    name: shunt_BC
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_BC[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_CA:
    name: shunt_CA
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_CA[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_AN:
    name: shunt_AN
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_AN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_BN:
    name: shunt_BN
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_BN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_CN:
    name: shunt_CN
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_CN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  residential_nominal_current_A:
    name: residential_nominal_current_A
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_A[A]
    description: posted current on phase A from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B:
    name: residential_nominal_current_B
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_B[A]
    description: posted current on phase B from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C:
    name: residential_nominal_current_C
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_C[A]
    description: posted current on phase C from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_A_real:
    name: residential_nominal_current_A_real
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_A_real[A]
    description: posted current on phase A, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_A_imag:
    name: residential_nominal_current_A_imag
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_A_imag[A]
    description: posted current on phase A, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B_real:
    name: residential_nominal_current_B_real
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_B_real[A]
    description: posted current on phase B, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B_imag:
    name: residential_nominal_current_B_imag
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_B_imag[A]
    description: posted current on phase B, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C_real:
    name: residential_nominal_current_C_real
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_C_real[A]
    description: posted current on phase C, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C_imag:
    name: residential_nominal_current_C_imag
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_C_imag[A]
    description: posted current on phase C, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  house_present:
    name: house_present
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: house_present
    description: boolean for detecting whether a house is attached, not an input
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  mean_repair_time:
    name: mean_repair_time
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mean_repair_time[s]
    description: Time after a fault clears for the object to be back in service
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    owner: meter
    domain_of:
    - link
    - node
    range: float
    required: false
    unit:
      ucum_code: s
  frequency_measure_type:
    name: frequency_measure_type
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: frequency_measure_type
    description: PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  sfm_Tf:
    name: sfm_Tf
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sfm_Tf[s]
    description: Transducer time constant for simplified frequency measurement (seconds)
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  pll_Kp:
    name: pll_Kp
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Kp[pu]
    description: Proportional gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  pll_Ki:
    name: pll_Ki
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Ki[pu]
    description: Integration gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  measured_angle_A:
    name: measured_angle_A
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_A[rad]
    description: bus angle measurement, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_A:
    name: measured_frequency_A
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_A[Hz]
    description: frequency measurement, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_B:
    name: measured_angle_B
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_B[rad]
    description: bus angle measurement, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_B:
    name: measured_frequency_B
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_B[Hz]
    description: frequency measurement, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_C:
    name: measured_angle_C
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_C[rad]
    description: bus angle measurement, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_C:
    name: measured_frequency_C
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_C[Hz]
    description: frequency measurement, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_frequency:
    name: measured_frequency
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency[Hz]
    description: frequency measurement - average of present phases
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  service_status:
    name: service_status
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: service_status
    description: In and out of service flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  service_status_double:
    name: service_status_double
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: service_status_double
    description: In and out of service flag - type double - will indiscriminately
      override service_status - useful for schedules
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
  previous_uptime:
    name: previous_uptime
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_uptime[min]
    description: Previous time between disconnects of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  current_uptime:
    name: current_uptime
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_uptime[min]
    description: Current time since last disconnect of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  Norton_dynamic:
    name: Norton_dynamic
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic
    description: Flag to indicate a Norton-equivalent connection -- used for generators
      and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  Norton_dynamic_child:
    name: Norton_dynamic_child
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic_child
    description: Flag to indicate a Norton-equivalent connection is made by a childed
      node object -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  generator_dynamic:
    name: generator_dynamic
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: generator_dynamic
    description: Flag to indicate a voltage-sourcing or swing-type generator is present
      -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  reset_disabled_island_state:
    name: reset_disabled_island_state
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: reset_disabled_island_state
    description: Deltamode/multi-island flag -- used to reset disabled status (and
      reform an island)
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_enable:
    name: GFA_enable
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_enable
    description: Disable/Enable Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_freq_low_trip:
    name: GFA_freq_low_trip
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_low_trip[Hz]
    description: Low frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_freq_high_trip:
    name: GFA_freq_high_trip
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_high_trip[Hz]
    description: High frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_volt_low_trip:
    name: GFA_volt_low_trip
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_low_trip[pu]
    description: Low voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_volt_high_trip:
    name: GFA_volt_high_trip
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_high_trip[pu]
    description: High voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_reconnect_time:
    name: GFA_reconnect_time
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_reconnect_time[s]
    description: Reconnect time for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_freq_disconnect_time:
    name: GFA_freq_disconnect_time
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_disconnect_time[s]
    description: Frequency violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_volt_disconnect_time:
    name: GFA_volt_disconnect_time
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_disconnect_time[s]
    description: Voltage violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_status:
    name: GFA_status
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_status
    description: Grid Friendly Appliance(TM)-type functionality - whether it is in
      service (not tripped) or not
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_trip_method:
    name: GFA_trip_method
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: GFA_trip_method
    description: GFA trip for over-voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  topological_parent:
    name: topological_parent
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: topological_parent
    description: topological parent as per GLM configuration
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  behaving_as_swing:
    name: behaving_as_swing
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: behaving_as_swing
    description: Indicator flag for if a bus is behaving as a reference voltage source
      - valid for a SWING or SWING_PQ
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: meter
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    comments:
    - 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
      Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
      Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
      when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
      bus); a switch or reactor side 1''s A, B, C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    related_mappings:
    - cim:Terminal.phases
    rank: 1000
    owner: meter
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  nominal_voltage:
    name: nominal_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_voltage[V]
    comments:
    - 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
      over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
      (V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
      LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
      / sqrt 3.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    close_mappings:
    - cim:BaseVoltage.nominalVoltage
    - cim:EnergySource.nominalVoltage
    rank: 1000
    owner: meter
    domain_of:
    - powerflow_object
    - battery
    - waterheater
    range: float
    required: false
    unit:
      ucum_code: V
  inrush_integration_method:
    name: inrush_integration_method
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method
    description: Integration method for in-rush
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: meter
    domain_of:
    - powerflow_object
    range: string
    required: false
  condition:
    name: condition
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: condition
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: meter
    domain_of:
    - powerflow_object
    range: string
    required: false
  solution:
    name: solution
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: solution
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: meter
    domain_of:
    - powerflow_object
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: meter
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: meter
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: meter
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: meter
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: meter
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: meter
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: meter
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: meter
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: meter
    domain_of:
    - glm_object
    range: string