Skip to content

Class: Motor

constructor. Class registration is only called once to

register the class with the core. Include parent class constructor (node)

@param mod a module structure maintained by the core

__

Inherits from: node

__

Type: Instance (network topology element)

URI: glm:Motor

 classDiagram
    class Motor
    click Motor href "../Motor/"
      Node <|-- Motor
        click Node href "../Node/"

      Motor : A_sat

      Motor : b_sat

      Motor : base_power

      Motor : behaving_as_swing

      Motor : busflags

      Motor : bustype

      Motor : capacitor_speed

      Motor : condition

      Motor : connected_house

      Motor : connected_house_assumed_mode

      Motor : contactor_close_Vmax

      Motor : contactor_open_Vmin

      Motor : contactor_state

      Motor : current_A





        Motor --> "0..1" Complex : current_A
        click Complex href "../Complex/"



      Motor : current_AB





        Motor --> "0..1" Complex : current_AB
        click Complex href "../Complex/"



      Motor : current_AN





        Motor --> "0..1" Complex : current_AN
        click Complex href "../Complex/"



      Motor : current_B





        Motor --> "0..1" Complex : current_B
        click Complex href "../Complex/"



      Motor : current_BC





        Motor --> "0..1" Complex : current_BC
        click Complex href "../Complex/"



      Motor : current_BN





        Motor --> "0..1" Complex : current_BN
        click Complex href "../Complex/"



      Motor : current_C





        Motor --> "0..1" Complex : current_C
        click Complex href "../Complex/"



      Motor : current_CA





        Motor --> "0..1" Complex : current_CA
        click Complex href "../Complex/"



      Motor : current_CN





        Motor --> "0..1" Complex : current_CN
        click Complex href "../Complex/"



      Motor : current_inj_A





        Motor --> "0..1" Complex : current_inj_A
        click Complex href "../Complex/"



      Motor : current_inj_B





        Motor --> "0..1" Complex : current_inj_B
        click Complex href "../Complex/"



      Motor : current_inj_C





        Motor --> "0..1" Complex : current_inj_C
        click Complex href "../Complex/"



      Motor : current_uptime

      Motor : delta_mode_rotor_speed_exit

      Motor : delta_mode_rotor_speed_trigger

      Motor : delta_mode_voltage_exit

      Motor : delta_mode_voltage_trigger

      Motor : deltamode_full_Y_all_matrix

      Motor : deltamode_full_Y_matrix

      Motor : deltamode_generator_current_A





        Motor --> "0..1" Complex : deltamode_generator_current_A
        click Complex href "../Complex/"



      Motor : deltamode_generator_current_B





        Motor --> "0..1" Complex : deltamode_generator_current_B
        click Complex href "../Complex/"



      Motor : deltamode_generator_current_C





        Motor --> "0..1" Complex : deltamode_generator_current_C
        click Complex href "../Complex/"



      Motor : deltamode_PGenTotal





        Motor --> "0..1" Complex : deltamode_PGenTotal
        click Complex href "../Complex/"



      Motor : desired_motor_state

      Motor : electrical_power





        Motor --> "0..1" Complex : electrical_power
        click Complex href "../Complex/"



      Motor : electrical_torque

      Motor : flags

      Motor : frequency_measure_type

      Motor : generator_dynamic

      Motor : GFA_enable

      Motor : GFA_freq_disconnect_time

      Motor : GFA_freq_high_trip

      Motor : GFA_freq_low_trip

      Motor : GFA_reconnect_time

      Motor : GFA_status

      Motor : GFA_trip_method

      Motor : GFA_volt_disconnect_time

      Motor : GFA_volt_high_trip

      Motor : GFA_volt_low_trip

      Motor : groupid

      Motor : H

      Motor : house_present

      Motor : Ias





        Motor --> "0..1" Complex : Ias
        click Complex href "../Complex/"



      Motor : Ib





        Motor --> "0..1" Complex : Ib
        click Complex href "../Complex/"



      Motor : Ibs





        Motor --> "0..1" Complex : Ibs
        click Complex href "../Complex/"



      Motor : Ics





        Motor --> "0..1" Complex : Ics
        click Complex href "../Complex/"



      Motor : Ids





        Motor --> "0..1" Complex : Ids
        click Complex href "../Complex/"



      Motor : If





        Motor --> "0..1" Complex : If
        click Complex href "../Complex/"



      Motor : in_svc

      Motor : Inr_cj





        Motor --> "0..1" Complex : Inr_cj
        click Complex href "../Complex/"



      Motor : inrush_integration_method

      Motor : Ins_cj





        Motor --> "0..1" Complex : Ins_cj
        click Complex href "../Complex/"



      Motor : Ipr





        Motor --> "0..1" Complex : Ipr
        click Complex href "../Complex/"



      Motor : Ips





        Motor --> "0..1" Complex : Ips
        click Complex href "../Complex/"



      Motor : Iqs





        Motor --> "0..1" Complex : Iqs
        click Complex href "../Complex/"



      Motor : Is





        Motor --> "0..1" Complex : Is
        click Complex href "../Complex/"



      Motor : iteration_count

      Motor : J

      Motor : latitude

      Motor : longitude

      Motor : Lr

      Motor : Ls

      Motor : maximum_speed_error

      Motor : maximum_voltage_error

      Motor : mean_repair_time

      Motor : measured_angle_A

      Motor : measured_angle_B

      Motor : measured_angle_C

      Motor : measured_frequency

      Motor : measured_frequency_A

      Motor : measured_frequency_B

      Motor : measured_frequency_C

      Motor : mechanical_torque

      Motor : mechanical_torque_state_var

      Motor : motor_operation_type

      Motor : motor_status





        Motor --> "0..1" MotorStatus : motor_status
        click MotorStatus href "../MotorStatus/"



      Motor : motor_status_number

      Motor : motor_trip

      Motor : n

      Motor : name

      Motor : nominal_voltage

      Motor : Norton_dynamic

      Motor : Norton_dynamic_child

      Motor : NR_powerflow_parent

      Motor : number_of_poles

      Motor : out_svc

      Motor : parent

      Motor : per_unit_rotor_speed

      Motor : phases

      Motor : phinr_cj





        Motor --> "0..1" Complex : phinr_cj
        click Complex href "../Complex/"



      Motor : phins_cj





        Motor --> "0..1" Complex : phins_cj
        click Complex href "../Complex/"



      Motor : phipr





        Motor --> "0..1" Complex : phipr
        click Complex href "../Complex/"



      Motor : phips





        Motor --> "0..1" Complex : phips
        click Complex href "../Complex/"



      Motor : pll_Ki

      Motor : pll_Kp

      Motor : power_A





        Motor --> "0..1" Complex : power_A
        click Complex href "../Complex/"



      Motor : power_AB





        Motor --> "0..1" Complex : power_AB
        click Complex href "../Complex/"



      Motor : power_AN





        Motor --> "0..1" Complex : power_AN
        click Complex href "../Complex/"



      Motor : power_B





        Motor --> "0..1" Complex : power_B
        click Complex href "../Complex/"



      Motor : power_BC





        Motor --> "0..1" Complex : power_BC
        click Complex href "../Complex/"



      Motor : power_BN





        Motor --> "0..1" Complex : power_BN
        click Complex href "../Complex/"



      Motor : power_C





        Motor --> "0..1" Complex : power_C
        click Complex href "../Complex/"



      Motor : power_CA





        Motor --> "0..1" Complex : power_CA
        click Complex href "../Complex/"



      Motor : power_CN





        Motor --> "0..1" Complex : power_CN
        click Complex href "../Complex/"



      Motor : prerotated_current_A





        Motor --> "0..1" Complex : prerotated_current_A
        click Complex href "../Complex/"



      Motor : prerotated_current_B





        Motor --> "0..1" Complex : prerotated_current_B
        click Complex href "../Complex/"



      Motor : prerotated_current_C





        Motor --> "0..1" Complex : prerotated_current_C
        click Complex href "../Complex/"



      Motor : previous_uptime

      Motor : psi_b





        Motor --> "0..1" Complex : psi_b
        click Complex href "../Complex/"



      Motor : psi_dr





        Motor --> "0..1" Complex : psi_dr
        click Complex href "../Complex/"



      Motor : psi_f





        Motor --> "0..1" Complex : psi_f
        click Complex href "../Complex/"



      Motor : psi_qr





        Motor --> "0..1" Complex : psi_qr
        click Complex href "../Complex/"



      Motor : rank

      Motor : Rds

      Motor : reconnect

      Motor : reconnect_time

      Motor : reference_bus

      Motor : reset_disabled_island_state

      Motor : residential_nominal_current_A





        Motor --> "0..1" Complex : residential_nominal_current_A
        click Complex href "../Complex/"



      Motor : residential_nominal_current_A_imag

      Motor : residential_nominal_current_A_real

      Motor : residential_nominal_current_B





        Motor --> "0..1" Complex : residential_nominal_current_B
        click Complex href "../Complex/"



      Motor : residential_nominal_current_B_imag

      Motor : residential_nominal_current_B_real

      Motor : residential_nominal_current_C





        Motor --> "0..1" Complex : residential_nominal_current_C
        click Complex href "../Complex/"



      Motor : residential_nominal_current_C_imag

      Motor : residential_nominal_current_C_real

      Motor : rotor_speed

      Motor : Rqs

      Motor : Rr

      Motor : Rs

      Motor : service_status

      Motor : service_status_double

      Motor : sfm_Tf

      Motor : shunt_A





        Motor --> "0..1" Complex : shunt_A
        click Complex href "../Complex/"



      Motor : shunt_AB





        Motor --> "0..1" Complex : shunt_AB
        click Complex href "../Complex/"



      Motor : shunt_AN





        Motor --> "0..1" Complex : shunt_AN
        click Complex href "../Complex/"



      Motor : shunt_B





        Motor --> "0..1" Complex : shunt_B
        click Complex href "../Complex/"



      Motor : shunt_BC





        Motor --> "0..1" Complex : shunt_BC
        click Complex href "../Complex/"



      Motor : shunt_BN





        Motor --> "0..1" Complex : shunt_BN
        click Complex href "../Complex/"



      Motor : shunt_C





        Motor --> "0..1" Complex : shunt_C
        click Complex href "../Complex/"



      Motor : shunt_CA





        Motor --> "0..1" Complex : shunt_CA
        click Complex href "../Complex/"



      Motor : shunt_CN





        Motor --> "0..1" Complex : shunt_CN
        click Complex href "../Complex/"



      Motor : sigma1

      Motor : sigma2

      Motor : solution

      Motor : time_step_divider

      Motor : To_prime

      Motor : topological_parent

      Motor : torque_usage_method

      Motor : trip

      Motor : trip_time

      Motor : triplex_connection_type

      Motor : uv_relay_install

      Motor : uv_relay_trip_time

      Motor : uv_relay_trip_V

      Motor : Vas





        Motor --> "0..1" Complex : Vas
        click Complex href "../Complex/"



      Motor : Vbs





        Motor --> "0..1" Complex : Vbs
        click Complex href "../Complex/"



      Motor : Vcs





        Motor --> "0..1" Complex : Vcs
        click Complex href "../Complex/"



      Motor : voltage_A





        Motor --> "0..1" Complex : voltage_A
        click Complex href "../Complex/"



      Motor : voltage_AB





        Motor --> "0..1" Complex : voltage_AB
        click Complex href "../Complex/"



      Motor : voltage_B





        Motor --> "0..1" Complex : voltage_B
        click Complex href "../Complex/"



      Motor : voltage_BC





        Motor --> "0..1" Complex : voltage_BC
        click Complex href "../Complex/"



      Motor : voltage_C





        Motor --> "0..1" Complex : voltage_C
        click Complex href "../Complex/"



      Motor : voltage_CA





        Motor --> "0..1" Complex : voltage_CA
        click Complex href "../Complex/"



      Motor : Vs





        Motor --> "0..1" Complex : Vs
        click Complex href "../Complex/"



      Motor : wb

      Motor : ws

      Motor : Xc_run

      Motor : Xc_start

      Motor : Xd_prime

      Motor : Xm

      Motor : Xq_prime

      Motor : Xr

      Motor : Xs

Inheritance

Slots

Name Cardinality and Range Description Inheritance
base_power 0..1
Float
base power direct
n 0..1
Float
ratio of stator auxiliary windings to stator main windings direct
Rds 0..1
Float
d-axis resistance - single-phase model direct
Rqs 0..1
Float
q-asis resistance - single-phase model direct
Rs 0..1
Float
stator resistance - three-phase model direct
Rr 0..1
Float
rotor resistance direct
Xm 0..1
Float
magnetizing reactance direct
Xr 0..1
Float
rotor reactance direct
Xs 0..1
Float
stator leakage reactance - three-phase model direct
Xc_run 0..1
Float
running capacitor reactance - single-phase model direct
Xc_start 0..1
Float
starting capacitor reactance - single-phase model direct
Xd_prime 0..1
Float
d-axis reactance - single-phase model direct
Xq_prime 0..1
Float
q-axis reactance - single-phase model direct
A_sat 0..1
Float
flux saturation parameter, A - single-phase model direct
b_sat 0..1
Float
flux saturation parameter, b - single-phase model direct
H 0..1
Float
inertia constant direct
J 0..1
Float
moment of inertia direct
number_of_poles 0..1
Float
number of poles direct
To_prime 0..1
Float
rotor time constant direct
capacitor_speed 0..1
Float
percentage speed of nominal when starting capacitor kicks in direct
trip_time 0..1
Float
time motor can stay stalled before tripping off direct
uv_relay_install 0..1
String
is under-voltage relay protection installed on this motor direct
uv_relay_trip_time 0..1
Float
time low-voltage condition must exist for under-voltage protection to trip direct
uv_relay_trip_V 0..1
Float
pu minimum voltage before under-voltage relay trips direct
contactor_state 0..1
String
the current status of the motor direct
contactor_open_Vmin 0..1
Float
pu voltage at which motor contactor opens direct
contactor_close_Vmax 0..1
Float
pu voltage at which motor contactor recloses direct
reconnect_time 0..1
Float
time before tripped motor reconnects direct
time_step_divider 0..1
Integer
divide time step by n - single- and three- phase models direct
mechanical_torque 0..1
Float
mechanical torque applied to the motor direct
mechanical_torque_state_var 0..1
Float
Internal state variable torque - three-phase model direct
torque_usage_method 0..1
String
Approach for using Tmech on both types direct
iteration_count 0..1
Integer
maximum number of iterations for steady state model direct
delta_mode_voltage_trigger 0..1
Float
percentage voltage of nominal when delta mode is triggered direct
delta_mode_rotor_speed_trigger 0..1
Float
percentage speed of nominal when delta mode is triggered direct
delta_mode_voltage_exit 0..1
Float
percentage voltage of nominal to exit delta mode direct
delta_mode_rotor_speed_exit 0..1
Float
percentage speed of nominal to exit delta mode direct
maximum_speed_error 0..1
Float
maximum speed error for transitioning modes direct
rotor_speed 0..1
Float
rotor speed direct
motor_status 0..1
MotorStatus
the current status of the motor direct
motor_status_number 0..1
Integer
the current status of the motor as an integer direct
desired_motor_state 0..1
String
Should the motor be on or off direct
connected_house 0..1
String
house object to monitor the XXX property to determine if the motor is running direct
connected_house_assumed_mode 0..1
String
Assumed operation mode of connected_house object direct
motor_operation_type 0..1
String
current operation type of the motor - deltamode related direct
triplex_connection_type 0..1
String
Describes how the motor will connect to the triplex devices direct
wb 0..1
Float
base speed direct
ws 0..1
Float
system speed direct
psi_b 0..1
Complex
backward rotating flux direct
psi_f 0..1
Complex
forward rotating flux direct
psi_dr 0..1
Complex
Rotor d axis flux direct
psi_qr 0..1
Complex
Rotor q axis flux direct
Ids 0..1
Complex
time before tripped motor reconnects direct
Iqs 0..1
Complex
time before tripped motor reconnects direct
If 0..1
Complex
forward current direct
Ib 0..1
Complex
backward current direct
Is 0..1
Complex
motor current direct
electrical_power 0..1
Complex
motor power direct
electrical_torque 0..1
Float
electrical torque direct
Vs 0..1
Complex
motor voltage direct
motor_trip 0..1
Boolean
boolean variable to check if motor is tripped direct
trip 0..1
Float
current time in tripped state direct
reconnect 0..1
Float
current time since motor was tripped direct
phips 0..1
Complex
positive sequence stator flux direct
phins_cj 0..1
Complex
conjugate of negative sequence stator flux direct
phipr 0..1
Complex
positive sequence rotor flux direct
phinr_cj 0..1
Complex
conjugate of negative sequence rotor flux direct
per_unit_rotor_speed 0..1
Float
rotor speed in per-unit direct
Ias 0..1
Complex
motor phase-a stator current direct
Ibs 0..1
Complex
motor phase-b stator current direct
Ics 0..1
Complex
motor phase-c stator current direct
Vas 0..1
Complex
motor phase-a stator-to-ground voltage direct
Vbs 0..1
Complex
motor phase-b stator-to-ground voltage direct
Vcs 0..1
Complex
motor phase-c stator-to-ground voltage direct
Ips 0..1
Complex
positive sequence stator current direct
Ipr 0..1
Complex
positive sequence rotor current direct
Ins_cj 0..1
Complex
conjugate of negative sequence stator current direct
Inr_cj 0..1
Complex
conjugate of negative sequence rotor current direct
Ls 0..1
Float
stator synchronous reactance direct
Lr 0..1
Float
rotor synchronous reactance direct
sigma1 0..1
Float
intermediate variable 1 associated with synch direct
sigma2 0..1
Float
intermediate variable 2 associated with synch direct
bustype 0..1
String
defines whether the node is a PQ, PV, or SWING node Node
busflags 0..1
String
flag indicates node has a source for voltage, i Node
reference_bus 0..1
String
reference bus from which frequency is defined Node
maximum_voltage_error 0..1
Float
convergence voltage limit or convergence criteria Node
voltage_A 0..1
Complex
bus voltage, Phase A to ground Node
voltage_B 0..1
Complex
bus voltage, Phase B to ground Node
voltage_C 0..1
Complex
bus voltage, Phase C to ground Node
voltage_AB 0..1
Complex
line voltages, Phase AB Node
voltage_BC 0..1
Complex
line voltages, Phase BC Node
voltage_CA 0..1
Complex
line voltages, Phase CA Node
current_A 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
current_B 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
current_C 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
power_A 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
power_B 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
power_C 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
shunt_A 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
shunt_B 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
shunt_C 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
prerotated_current_A 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
prerotated_current_B 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
prerotated_current_C 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
deltamode_generator_current_A 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_generator_current_B 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_generator_current_C 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_PGenTotal 0..1
Complex
deltamode-functionality - power value for a diesel generator -- accumulator o... Node
deltamode_full_Y_matrix 0..1
String
deltamode-functionality full_Y matrix exposes so generator objects can intera... Node
deltamode_full_Y_all_matrix 0..1
String
deltamode-functionality full_Y_all matrix exposes so generator objects can in... Node
NR_powerflow_parent 0..1
String
NR powerflow - actual powerflow parent - used by generators accessing child o... Node
current_inj_A 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_inj_B 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_inj_C 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_AB 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_BC 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_CA 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_AN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
current_BN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
current_CN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
power_AB 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_BC 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_CA 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_AN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
power_BN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
power_CN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
shunt_AB 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_BC 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_CA 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_AN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
shunt_BN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
shunt_CN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
residential_nominal_current_A 0..1
Complex
posted current on phase A from a residential object, if attached Node
residential_nominal_current_B 0..1
Complex
posted current on phase B from a residential object, if attached Node
residential_nominal_current_C 0..1
Complex
posted current on phase C from a residential object, if attached Node
residential_nominal_current_A_real 0..1
Float
posted current on phase A, real, from a residential object, if attached Node
residential_nominal_current_A_imag 0..1
Float
posted current on phase A, imag, from a residential object, if attached Node
residential_nominal_current_B_real 0..1
Float
posted current on phase B, real, from a residential object, if attached Node
residential_nominal_current_B_imag 0..1
Float
posted current on phase B, imag, from a residential object, if attached Node
residential_nominal_current_C_real 0..1
Float
posted current on phase C, real, from a residential object, if attached Node
residential_nominal_current_C_imag 0..1
Float
posted current on phase C, imag, from a residential object, if attached Node
house_present 0..1
Boolean
boolean for detecting whether a house is attached, not an input Node
mean_repair_time 0..1
Float
Time after a fault clears for the object to be back in service Node
frequency_measure_type 0..1
String
PLL frequency measurement Node
sfm_Tf 0..1
Float
Transducer time constant for simplified frequency measurement (seconds) Node
pll_Kp 0..1
Float
Proportional gain of PLL frequency measurement Node
pll_Ki 0..1
Float
Integration gain of PLL frequency measurement Node
measured_angle_A 0..1
Float
bus angle measurement, phase A Node
measured_frequency_A 0..1
Float
frequency measurement, phase A Node
measured_angle_B 0..1
Float
bus angle measurement, phase B Node
measured_frequency_B 0..1
Float
frequency measurement, phase B Node
measured_angle_C 0..1
Float
bus angle measurement, phase C Node
measured_frequency_C 0..1
Float
frequency measurement, phase C Node
measured_frequency 0..1
Float
frequency measurement - average of present phases Node
service_status 0..1
String
In and out of service flag Node
service_status_double 0..1
Float
In and out of service flag - type double - will indiscriminately override ser... Node
previous_uptime 0..1
Float
Previous time between disconnects of node in minutes Node
current_uptime 0..1
Float
Current time since last disconnect of node in minutes Node
Norton_dynamic 0..1
Boolean
Flag to indicate a Norton-equivalent connection -- used for generators and de... Node
Norton_dynamic_child 0..1
Boolean
Flag to indicate a Norton-equivalent connection is made by a childed node obj... Node
generator_dynamic 0..1
Boolean
Flag to indicate a voltage-sourcing or swing-type generator is present -- use... Node
reset_disabled_island_state 0..1
Boolean
Deltamode/multi-island flag -- used to reset disabled status (and reform an i... Node
GFA_enable 0..1
Boolean
Disable/Enable Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_low_trip 0..1
Float
Low frequency trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_high_trip 0..1
Float
High frequency trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_volt_low_trip 0..1
Float
Low voltage trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_volt_high_trip 0..1
Float
High voltage trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_reconnect_time 0..1
Float
Reconnect time for Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_disconnect_time 0..1
Float
Frequency violation disconnect time for Grid Friendly Appliance(TM)-type func... Node
GFA_volt_disconnect_time 0..1
Float
Voltage violation disconnect time for Grid Friendly Appliance(TM)-type functi... Node
GFA_status 0..1
Boolean
Grid Friendly Appliance(TM)-type functionality - whether it is in service (no... Node
GFA_trip_method 0..1
String
GFA trip for over-voltage Node
topological_parent 0..1
String
topological parent as per GLM configuration Node
behaving_as_swing 0..1
Boolean
Indicator flag for if a bus is behaving as a reference voltage source - valid... Node
phases 0..1
String
PowerflowObject
nominal_voltage 0..1
Float
PowerflowObject
inrush_integration_method 0..1
String
Integration method for in-rush PowerflowObject
condition 0..1
String
PowerflowObject
solution 0..1
String
PowerflowObject
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • CIMHub does not convert this class. The importer reads no property of it and lists it, with its count, on the master's not-mapped comment; the exporter writes none.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:Motor
native glm:Motor

LinkML Source

Direct

name: motor
description: 'constructor.  Class registration is only called once to

  register the class with the core. Include parent class constructor (node)

  @param mod a module structure maintained by the core


  Inherits from: node


  Type: Instance (network topology element)'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
  it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: node
attributes:
  base_power:
    name: base_power
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power[W]
    description: base power
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    - substation
    - ZIPload
    range: float
    required: false
    unit:
      ucum_code: W
  n:
    name: n
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: n
    description: ratio of stator auxiliary windings to stator main windings
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  Rds:
    name: Rds
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rds[ohm]
    description: d-axis resistance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Rqs:
    name: Rqs
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rqs[ohm]
    description: q-asis resistance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Rs:
    name: Rs
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rs[ohm]
    description: stator resistance - three-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: ohm
  Rr:
    name: Rr
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rr[ohm]
    description: rotor resistance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xm:
    name: Xm
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xm[ohm]
    description: magnetizing reactance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xr:
    name: Xr
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xr[ohm]
    description: rotor reactance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xs:
    name: Xs
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xs[ohm]
    description: stator leakage reactance - three-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xc_run:
    name: Xc_run
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xc_run[ohm]
    description: running capacitor reactance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xc_start:
    name: Xc_start
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xc_start[ohm]
    description: starting capacitor reactance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xd_prime:
    name: Xd_prime
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xd_prime[ohm]
    description: d-axis reactance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xq_prime:
    name: Xq_prime
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xq_prime[ohm]
    description: q-axis reactance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  A_sat:
    name: A_sat
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: A_sat
    description: flux saturation parameter, A - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  b_sat:
    name: b_sat
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b_sat
    description: flux saturation parameter, b - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  H:
    name: H
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: H[s]
    description: inertia constant
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: s
  J:
    name: J
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: J[kg*m^2]
    description: moment of inertia
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: kg*m^2
  number_of_poles:
    name: number_of_poles
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: number_of_poles
    description: number of poles
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  To_prime:
    name: To_prime
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: To_prime[s]
    description: rotor time constant
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: s
  capacitor_speed:
    name: capacitor_speed
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: capacitor_speed[%]
    description: percentage speed of nominal when starting capacitor kicks in
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  trip_time:
    name: trip_time
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: trip_time[s]
    description: 'time motor can stay stalled before tripping off '
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: s
  uv_relay_install:
    name: uv_relay_install
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: uv_relay_install
    description: is under-voltage relay protection installed on this motor
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: string
    required: false
  uv_relay_trip_time:
    name: uv_relay_trip_time
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: uv_relay_trip_time[s]
    description: 'time low-voltage condition must exist for under-voltage protection
      to trip '
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: s
  uv_relay_trip_V:
    name: uv_relay_trip_V
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: uv_relay_trip_V[pu]
    description: pu minimum voltage before under-voltage relay trips
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  contactor_state:
    name: contactor_state
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: contactor_state
    description: the current status of the motor
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: string
    required: false
  contactor_open_Vmin:
    name: contactor_open_Vmin
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: contactor_open_Vmin[pu]
    description: pu voltage at which motor contactor opens
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  contactor_close_Vmax:
    name: contactor_close_Vmax
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: contactor_close_Vmax[pu]
    description: pu voltage at which motor contactor recloses
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  reconnect_time:
    name: reconnect_time
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: reconnect_time[s]
    description: time before tripped motor reconnects
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    - performance_motor
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  time_step_divider:
    name: time_step_divider
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: time_step_divider
    description: divide time step by n - single- and three- phase models
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: integer
    required: false
  mechanical_torque:
    name: mechanical_torque
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mechanical_torque[pu]
    description: mechanical torque applied to the motor
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  mechanical_torque_state_var:
    name: mechanical_torque_state_var
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mechanical_torque_state_var[pu]
    description: Internal state variable torque - three-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  torque_usage_method:
    name: torque_usage_method
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: torque_usage_method
    description: Approach for using Tmech on both types
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: string
    required: false
  iteration_count:
    name: iteration_count
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: iteration_count
    description: maximum number of iterations for steady state model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: integer
    required: false
  delta_mode_voltage_trigger:
    name: delta_mode_voltage_trigger
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mode_voltage_trigger[%]
    description: percentage voltage of nominal when delta mode is triggered
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  delta_mode_rotor_speed_trigger:
    name: delta_mode_rotor_speed_trigger
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mode_rotor_speed_trigger[%]
    description: percentage speed of nominal when delta mode is triggered
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  delta_mode_voltage_exit:
    name: delta_mode_voltage_exit
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mode_voltage_exit[%]
    description: percentage voltage of nominal to exit delta mode
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  delta_mode_rotor_speed_exit:
    name: delta_mode_rotor_speed_exit
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mode_rotor_speed_exit[%]
    description: percentage speed of nominal to exit delta mode
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  maximum_speed_error:
    name: maximum_speed_error
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_speed_error
    description: maximum speed error for transitioning modes
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  rotor_speed:
    name: rotor_speed
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: rotor_speed[rad/s]
    description: rotor speed
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    - diesel_dg
    range: float
    required: false
    unit:
      ucum_code: rad/s
  motor_status:
    name: motor_status
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: motor_status
    description: the current status of the motor
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    - performance_motor
    range: MotorStatus
    required: false
  motor_status_number:
    name: motor_status_number
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: motor_status_number
    description: the current status of the motor as an integer
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    - performance_motor
    range: integer
    required: false
  desired_motor_state:
    name: desired_motor_state
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: desired_motor_state
    description: Should the motor be on or off
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: string
    required: false
  connected_house:
    name: connected_house
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: connected_house
    description: house object to monitor the XXX property to determine if the motor
      is running
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: string
    required: false
  connected_house_assumed_mode:
    name: connected_house_assumed_mode
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: connected_house_assumed_mode
    description: Assumed operation mode of connected_house object
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: string
    required: false
  motor_operation_type:
    name: motor_operation_type
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: motor_operation_type
    description: current operation type of the motor - deltamode related
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: string
    required: false
  triplex_connection_type:
    name: triplex_connection_type
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: triplex_connection_type
    description: Describes how the motor will connect to the triplex devices
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: string
    required: false
  wb:
    name: wb
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wb[rad/s]
    description: base speed
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: rad/s
  ws:
    name: ws
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ws[rad/s]
    description: system speed
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: rad/s
  psi_b:
    name: psi_b
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: psi_b
    description: backward rotating flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  psi_f:
    name: psi_f
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: psi_f
    description: forward rotating flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  psi_dr:
    name: psi_dr
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: psi_dr
    description: Rotor d axis flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  psi_qr:
    name: psi_qr
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: psi_qr
    description: Rotor q axis flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  Ids:
    name: Ids
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ids
    description: time before tripped motor reconnects
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  Iqs:
    name: Iqs
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Iqs
    description: time before tripped motor reconnects
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  If:
    name: If
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: If
    description: forward current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  Ib:
    name: Ib
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ib
    description: backward current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  Is:
    name: Is
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Is
    description: motor current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  electrical_power:
    name: electrical_power
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: electrical_power[VA]
    description: motor power
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: VA
  electrical_torque:
    name: electrical_torque
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: electrical_torque[pu]
    description: electrical torque
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  Vs:
    name: Vs
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vs
    description: motor voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  motor_trip:
    name: motor_trip
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: motor_trip
    description: boolean variable to check if motor is tripped
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: boolean
    required: false
  trip:
    name: trip
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: trip
    description: current time in tripped state
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  reconnect:
    name: reconnect
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: reconnect
    description: current time since motor was tripped
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  phips:
    name: phips
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phips
    description: positive sequence stator flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  phins_cj:
    name: phins_cj
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phins_cj
    description: conjugate of negative sequence stator flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  phipr:
    name: phipr
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phipr
    description: positive sequence rotor flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  phinr_cj:
    name: phinr_cj
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phinr_cj
    description: conjugate of negative sequence rotor flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  per_unit_rotor_speed:
    name: per_unit_rotor_speed
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: per_unit_rotor_speed[pu]
    description: rotor speed in per-unit
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  Ias:
    name: Ias
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ias[pu]
    description: motor phase-a stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Ibs:
    name: Ibs
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ibs[pu]
    description: motor phase-b stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Ics:
    name: Ics
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ics[pu]
    description: motor phase-c stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Vas:
    name: Vas
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vas[pu]
    description: motor phase-a stator-to-ground voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Vbs:
    name: Vbs
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vbs[pu]
    description: motor phase-b stator-to-ground voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Vcs:
    name: Vcs
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vcs[pu]
    description: motor phase-c stator-to-ground voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Ips:
    name: Ips
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ips
    description: positive sequence stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  Ipr:
    name: Ipr
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ipr
    description: positive sequence rotor current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  Ins_cj:
    name: Ins_cj
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ins_cj
    description: conjugate of negative sequence stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  Inr_cj:
    name: Inr_cj
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Inr_cj
    description: conjugate of negative sequence rotor current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: Complex
    required: false
  Ls:
    name: Ls
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ls
    description: stator synchronous reactance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  Lr:
    name: Lr
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Lr
    description: rotor synchronous reactance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  sigma1:
    name: sigma1
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sigma1
    description: intermediate variable 1 associated with synch. react.
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false
  sigma2:
    name: sigma2
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sigma2
    description: intermediate variable 2 associated with synch. react.
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    domain_of:
    - motor
    range: float
    required: false

Induced

name: motor
description: 'constructor.  Class registration is only called once to

  register the class with the core. Include parent class constructor (node)

  @param mod a module structure maintained by the core


  Inherits from: node


  Type: Instance (network topology element)'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
  it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: node
attributes:
  base_power:
    name: base_power
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power[W]
    description: base power
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    - substation
    - ZIPload
    range: float
    required: false
    unit:
      ucum_code: W
  n:
    name: n
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: n
    description: ratio of stator auxiliary windings to stator main windings
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  Rds:
    name: Rds
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rds[ohm]
    description: d-axis resistance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Rqs:
    name: Rqs
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rqs[ohm]
    description: q-asis resistance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Rs:
    name: Rs
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rs[ohm]
    description: stator resistance - three-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: ohm
  Rr:
    name: Rr
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rr[ohm]
    description: rotor resistance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xm:
    name: Xm
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xm[ohm]
    description: magnetizing reactance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xr:
    name: Xr
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xr[ohm]
    description: rotor reactance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xs:
    name: Xs
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xs[ohm]
    description: stator leakage reactance - three-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xc_run:
    name: Xc_run
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xc_run[ohm]
    description: running capacitor reactance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xc_start:
    name: Xc_start
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xc_start[ohm]
    description: starting capacitor reactance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xd_prime:
    name: Xd_prime
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xd_prime[ohm]
    description: d-axis reactance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  Xq_prime:
    name: Xq_prime
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Xq_prime[ohm]
    description: q-axis reactance - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: ohm
  A_sat:
    name: A_sat
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: A_sat
    description: flux saturation parameter, A - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  b_sat:
    name: b_sat
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b_sat
    description: flux saturation parameter, b - single-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  H:
    name: H
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: H[s]
    description: inertia constant
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: s
  J:
    name: J
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: J[kg*m^2]
    description: moment of inertia
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: kg*m^2
  number_of_poles:
    name: number_of_poles
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: number_of_poles
    description: number of poles
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  To_prime:
    name: To_prime
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: To_prime[s]
    description: rotor time constant
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: s
  capacitor_speed:
    name: capacitor_speed
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: capacitor_speed[%]
    description: percentage speed of nominal when starting capacitor kicks in
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  trip_time:
    name: trip_time
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: trip_time[s]
    description: 'time motor can stay stalled before tripping off '
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: s
  uv_relay_install:
    name: uv_relay_install
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: uv_relay_install
    description: is under-voltage relay protection installed on this motor
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: string
    required: false
  uv_relay_trip_time:
    name: uv_relay_trip_time
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: uv_relay_trip_time[s]
    description: 'time low-voltage condition must exist for under-voltage protection
      to trip '
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: s
  uv_relay_trip_V:
    name: uv_relay_trip_V
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: uv_relay_trip_V[pu]
    description: pu minimum voltage before under-voltage relay trips
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  contactor_state:
    name: contactor_state
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: contactor_state
    description: the current status of the motor
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: string
    required: false
  contactor_open_Vmin:
    name: contactor_open_Vmin
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: contactor_open_Vmin[pu]
    description: pu voltage at which motor contactor opens
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  contactor_close_Vmax:
    name: contactor_close_Vmax
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: contactor_close_Vmax[pu]
    description: pu voltage at which motor contactor recloses
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  reconnect_time:
    name: reconnect_time
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: reconnect_time[s]
    description: time before tripped motor reconnects
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    - performance_motor
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  time_step_divider:
    name: time_step_divider
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: time_step_divider
    description: divide time step by n - single- and three- phase models
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: integer
    required: false
  mechanical_torque:
    name: mechanical_torque
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mechanical_torque[pu]
    description: mechanical torque applied to the motor
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  mechanical_torque_state_var:
    name: mechanical_torque_state_var
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mechanical_torque_state_var[pu]
    description: Internal state variable torque - three-phase model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  torque_usage_method:
    name: torque_usage_method
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: torque_usage_method
    description: Approach for using Tmech on both types
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: string
    required: false
  iteration_count:
    name: iteration_count
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: iteration_count
    description: maximum number of iterations for steady state model
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: integer
    required: false
  delta_mode_voltage_trigger:
    name: delta_mode_voltage_trigger
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mode_voltage_trigger[%]
    description: percentage voltage of nominal when delta mode is triggered
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  delta_mode_rotor_speed_trigger:
    name: delta_mode_rotor_speed_trigger
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mode_rotor_speed_trigger[%]
    description: percentage speed of nominal when delta mode is triggered
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  delta_mode_voltage_exit:
    name: delta_mode_voltage_exit
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mode_voltage_exit[%]
    description: percentage voltage of nominal to exit delta mode
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  delta_mode_rotor_speed_exit:
    name: delta_mode_rotor_speed_exit
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mode_rotor_speed_exit[%]
    description: percentage speed of nominal to exit delta mode
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: '%'
  maximum_speed_error:
    name: maximum_speed_error
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_speed_error
    description: maximum speed error for transitioning modes
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  rotor_speed:
    name: rotor_speed
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: rotor_speed[rad/s]
    description: rotor speed
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    - diesel_dg
    range: float
    required: false
    unit:
      ucum_code: rad/s
  motor_status:
    name: motor_status
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: motor_status
    description: the current status of the motor
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    - performance_motor
    range: MotorStatus
    required: false
  motor_status_number:
    name: motor_status_number
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: motor_status_number
    description: the current status of the motor as an integer
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    - performance_motor
    range: integer
    required: false
  desired_motor_state:
    name: desired_motor_state
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: desired_motor_state
    description: Should the motor be on or off
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: string
    required: false
  connected_house:
    name: connected_house
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: connected_house
    description: house object to monitor the XXX property to determine if the motor
      is running
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: string
    required: false
  connected_house_assumed_mode:
    name: connected_house_assumed_mode
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: connected_house_assumed_mode
    description: Assumed operation mode of connected_house object
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: string
    required: false
  motor_operation_type:
    name: motor_operation_type
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: motor_operation_type
    description: current operation type of the motor - deltamode related
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: string
    required: false
  triplex_connection_type:
    name: triplex_connection_type
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: triplex_connection_type
    description: Describes how the motor will connect to the triplex devices
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: string
    required: false
  wb:
    name: wb
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wb[rad/s]
    description: base speed
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: rad/s
  ws:
    name: ws
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ws[rad/s]
    description: system speed
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: rad/s
  psi_b:
    name: psi_b
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: psi_b
    description: backward rotating flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  psi_f:
    name: psi_f
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: psi_f
    description: forward rotating flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  psi_dr:
    name: psi_dr
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: psi_dr
    description: Rotor d axis flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  psi_qr:
    name: psi_qr
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: psi_qr
    description: Rotor q axis flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  Ids:
    name: Ids
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ids
    description: time before tripped motor reconnects
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  Iqs:
    name: Iqs
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Iqs
    description: time before tripped motor reconnects
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  If:
    name: If
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: If
    description: forward current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  Ib:
    name: Ib
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ib
    description: backward current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  Is:
    name: Is
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Is
    description: motor current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  electrical_power:
    name: electrical_power
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: electrical_power[VA]
    description: motor power
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: VA
  electrical_torque:
    name: electrical_torque
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: electrical_torque[pu]
    description: electrical torque
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  Vs:
    name: Vs
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vs
    description: motor voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  motor_trip:
    name: motor_trip
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: motor_trip
    description: boolean variable to check if motor is tripped
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: boolean
    required: false
  trip:
    name: trip
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: trip
    description: current time in tripped state
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  reconnect:
    name: reconnect
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: reconnect
    description: current time since motor was tripped
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  phips:
    name: phips
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phips
    description: positive sequence stator flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  phins_cj:
    name: phins_cj
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phins_cj
    description: conjugate of negative sequence stator flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  phipr:
    name: phipr
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phipr
    description: positive sequence rotor flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  phinr_cj:
    name: phinr_cj
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phinr_cj
    description: conjugate of negative sequence rotor flux
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  per_unit_rotor_speed:
    name: per_unit_rotor_speed
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: per_unit_rotor_speed[pu]
    description: rotor speed in per-unit
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
    unit:
      ucum_code: pu
  Ias:
    name: Ias
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ias[pu]
    description: motor phase-a stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Ibs:
    name: Ibs
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ibs[pu]
    description: motor phase-b stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Ics:
    name: Ics
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ics[pu]
    description: motor phase-c stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Vas:
    name: Vas
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vas[pu]
    description: motor phase-a stator-to-ground voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Vbs:
    name: Vbs
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vbs[pu]
    description: motor phase-b stator-to-ground voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Vcs:
    name: Vcs
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Vcs[pu]
    description: motor phase-c stator-to-ground voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
    unit:
      ucum_code: pu
  Ips:
    name: Ips
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ips
    description: positive sequence stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  Ipr:
    name: Ipr
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ipr
    description: positive sequence rotor current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  Ins_cj:
    name: Ins_cj
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Ins_cj
    description: conjugate of negative sequence stator current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  Inr_cj:
    name: Inr_cj
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: Inr_cj
    description: conjugate of negative sequence rotor current
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: Complex
    required: false
  Ls:
    name: Ls
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Ls
    description: stator synchronous reactance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  Lr:
    name: Lr
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Lr
    description: rotor synchronous reactance
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  sigma1:
    name: sigma1
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sigma1
    description: intermediate variable 1 associated with synch. react.
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  sigma2:
    name: sigma2
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sigma2
    description: intermediate variable 2 associated with synch. react.
    from_schema: https://gridlabd.org/schema/glm/powerflow/motor
    rank: 1000
    owner: motor
    domain_of:
    - motor
    range: float
    required: false
  bustype:
    name: bustype
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: bustype
    description: defines whether the node is a PQ, PV, or SWING node
    comments:
    - 'Import: SWING makes an EnergySource; PQ, PV and SWING_PQ are a plain bus (SWING_PQ
      is a swing only when islanded). Export: SWING on the substation only.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    related_mappings:
    - cim:EnergySource
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  busflags:
    name: busflags
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: busflags
    description: flag indicates node has a source for voltage, i.e. connects to the
      swing node
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  reference_bus:
    name: reference_bus
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reference_bus
    description: reference bus from which frequency is defined
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  maximum_voltage_error:
    name: maximum_voltage_error
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_voltage_error[V]
    description: convergence voltage limit or convergence criteria
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: V
  voltage_A:
    name: voltage_A
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_A[V]
    description: bus voltage, Phase A to ground
    comments:
    - 'Import: on a SWING bus only: EnergySource.voltageMagnitude (line to line) and
      voltageAngle (deg) from |V| and arg(V); elsewhere the solver guess, not converted.
      Export: not written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    close_mappings:
    - cim:EnergySource.voltageMagnitude
    - cim:EnergySource.voltageAngle
    rank: 1000
    owner: motor
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_B:
    name: voltage_B
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_B[V]
    description: bus voltage, Phase B to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_C:
    name: voltage_C
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_C[V]
    description: bus voltage, Phase C to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_AB:
    name: voltage_AB
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_AB[V]
    description: line voltages, Phase AB
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_BC:
    name: voltage_BC
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_BC[V]
    description: line voltages, Phase BC
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_CA:
    name: voltage_CA
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_CA[V]
    description: line voltages, Phase CA
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  current_A:
    name: current_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_A[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_B:
    name: current_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_B[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_C:
    name: current_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_C[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_A:
    name: power_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_A[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_B:
    name: power_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_B[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_C:
    name: power_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_C[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_A:
    name: shunt_A
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_A[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_B:
    name: shunt_B
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_B[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_C:
    name: shunt_C
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_C[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  prerotated_current_A:
    name: prerotated_current_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_A[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_B:
    name: prerotated_current_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_B[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_C:
    name: prerotated_current_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_C[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_A:
    name: deltamode_generator_current_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_A[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_B:
    name: deltamode_generator_current_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_B[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_C:
    name: deltamode_generator_current_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_C[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_PGenTotal:
    name: deltamode_PGenTotal
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_PGenTotal
    description: deltamode-functionality - power value for a diesel generator -- accumulator
      only, not an output or input
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: Complex
    required: false
  deltamode_full_Y_matrix:
    name: deltamode_full_Y_matrix
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_matrix
    description: deltamode-functionality full_Y matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  deltamode_full_Y_all_matrix:
    name: deltamode_full_Y_all_matrix
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_all_matrix
    description: deltamode-functionality full_Y_all matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  NR_powerflow_parent:
    name: NR_powerflow_parent
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: NR_powerflow_parent
    description: NR powerflow - actual powerflow parent - used by generators accessing
      child objects
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  current_inj_A:
    name: current_inj_A
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_A[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_inj_B:
    name: current_inj_B
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_B[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_inj_C:
    name: current_inj_C
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_C[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_AB:
    name: current_AB
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_AB[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_BC:
    name: current_BC
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_BC[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_CA:
    name: current_CA
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_CA[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_AN:
    name: current_AN
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_AN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_BN:
    name: current_BN
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_BN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_CN:
    name: current_CN
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_CN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_AB:
    name: power_AB
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_AB[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_BC:
    name: power_BC
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_BC[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_CA:
    name: power_CA
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_CA[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_AN:
    name: power_AN
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_AN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_BN:
    name: power_BN
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_BN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_CN:
    name: power_CN
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_CN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_AB:
    name: shunt_AB
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_AB[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_BC:
    name: shunt_BC
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_BC[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_CA:
    name: shunt_CA
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_CA[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_AN:
    name: shunt_AN
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_AN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_BN:
    name: shunt_BN
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_BN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_CN:
    name: shunt_CN
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_CN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  residential_nominal_current_A:
    name: residential_nominal_current_A
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_A[A]
    description: posted current on phase A from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B:
    name: residential_nominal_current_B
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_B[A]
    description: posted current on phase B from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C:
    name: residential_nominal_current_C
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_C[A]
    description: posted current on phase C from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_A_real:
    name: residential_nominal_current_A_real
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_A_real[A]
    description: posted current on phase A, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_A_imag:
    name: residential_nominal_current_A_imag
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_A_imag[A]
    description: posted current on phase A, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B_real:
    name: residential_nominal_current_B_real
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_B_real[A]
    description: posted current on phase B, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B_imag:
    name: residential_nominal_current_B_imag
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_B_imag[A]
    description: posted current on phase B, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C_real:
    name: residential_nominal_current_C_real
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_C_real[A]
    description: posted current on phase C, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C_imag:
    name: residential_nominal_current_C_imag
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_C_imag[A]
    description: posted current on phase C, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  house_present:
    name: house_present
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: house_present
    description: boolean for detecting whether a house is attached, not an input
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  mean_repair_time:
    name: mean_repair_time
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mean_repair_time[s]
    description: Time after a fault clears for the object to be back in service
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    owner: motor
    domain_of:
    - link
    - node
    range: float
    required: false
    unit:
      ucum_code: s
  frequency_measure_type:
    name: frequency_measure_type
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: frequency_measure_type
    description: PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  sfm_Tf:
    name: sfm_Tf
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sfm_Tf[s]
    description: Transducer time constant for simplified frequency measurement (seconds)
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  pll_Kp:
    name: pll_Kp
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Kp[pu]
    description: Proportional gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  pll_Ki:
    name: pll_Ki
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Ki[pu]
    description: Integration gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  measured_angle_A:
    name: measured_angle_A
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_A[rad]
    description: bus angle measurement, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_A:
    name: measured_frequency_A
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_A[Hz]
    description: frequency measurement, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_B:
    name: measured_angle_B
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_B[rad]
    description: bus angle measurement, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_B:
    name: measured_frequency_B
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_B[Hz]
    description: frequency measurement, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_C:
    name: measured_angle_C
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_C[rad]
    description: bus angle measurement, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_C:
    name: measured_frequency_C
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_C[Hz]
    description: frequency measurement, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_frequency:
    name: measured_frequency
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency[Hz]
    description: frequency measurement - average of present phases
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  service_status:
    name: service_status
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: service_status
    description: In and out of service flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  service_status_double:
    name: service_status_double
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: service_status_double
    description: In and out of service flag - type double - will indiscriminately
      override service_status - useful for schedules
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
  previous_uptime:
    name: previous_uptime
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_uptime[min]
    description: Previous time between disconnects of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  current_uptime:
    name: current_uptime
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_uptime[min]
    description: Current time since last disconnect of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  Norton_dynamic:
    name: Norton_dynamic
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic
    description: Flag to indicate a Norton-equivalent connection -- used for generators
      and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  Norton_dynamic_child:
    name: Norton_dynamic_child
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic_child
    description: Flag to indicate a Norton-equivalent connection is made by a childed
      node object -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  generator_dynamic:
    name: generator_dynamic
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: generator_dynamic
    description: Flag to indicate a voltage-sourcing or swing-type generator is present
      -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  reset_disabled_island_state:
    name: reset_disabled_island_state
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: reset_disabled_island_state
    description: Deltamode/multi-island flag -- used to reset disabled status (and
      reform an island)
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_enable:
    name: GFA_enable
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_enable
    description: Disable/Enable Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_freq_low_trip:
    name: GFA_freq_low_trip
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_low_trip[Hz]
    description: Low frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_freq_high_trip:
    name: GFA_freq_high_trip
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_high_trip[Hz]
    description: High frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_volt_low_trip:
    name: GFA_volt_low_trip
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_low_trip[pu]
    description: Low voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_volt_high_trip:
    name: GFA_volt_high_trip
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_high_trip[pu]
    description: High voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_reconnect_time:
    name: GFA_reconnect_time
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_reconnect_time[s]
    description: Reconnect time for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_freq_disconnect_time:
    name: GFA_freq_disconnect_time
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_disconnect_time[s]
    description: Frequency violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_volt_disconnect_time:
    name: GFA_volt_disconnect_time
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_disconnect_time[s]
    description: Voltage violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_status:
    name: GFA_status
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_status
    description: Grid Friendly Appliance(TM)-type functionality - whether it is in
      service (not tripped) or not
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_trip_method:
    name: GFA_trip_method
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: GFA_trip_method
    description: GFA trip for over-voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  topological_parent:
    name: topological_parent
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: topological_parent
    description: topological parent as per GLM configuration
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  behaving_as_swing:
    name: behaving_as_swing
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: behaving_as_swing
    description: Indicator flag for if a bus is behaving as a reference voltage source
      - valid for a SWING or SWING_PQ
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: motor
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    comments:
    - 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
      Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
      Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
      when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
      bus); a switch or reactor side 1''s A, B, C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    related_mappings:
    - cim:Terminal.phases
    rank: 1000
    owner: motor
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  nominal_voltage:
    name: nominal_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_voltage[V]
    comments:
    - 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
      over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
      (V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
      LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
      / sqrt 3.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    close_mappings:
    - cim:BaseVoltage.nominalVoltage
    - cim:EnergySource.nominalVoltage
    rank: 1000
    owner: motor
    domain_of:
    - powerflow_object
    - battery
    - waterheater
    range: float
    required: false
    unit:
      ucum_code: V
  inrush_integration_method:
    name: inrush_integration_method
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method
    description: Integration method for in-rush
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: motor
    domain_of:
    - powerflow_object
    range: string
    required: false
  condition:
    name: condition
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: condition
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: motor
    domain_of:
    - powerflow_object
    range: string
    required: false
  solution:
    name: solution
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: solution
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: motor
    domain_of:
    - powerflow_object
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: motor
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: motor
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: motor
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: motor
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: motor
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: motor
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: motor
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: motor
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: motor
    domain_of:
    - glm_object
    range: string