Skip to content

Class: Solar

// Assumptions:

1. All solar panels are tilted as per the site latitude to perform at their best efficiency

2. All the solar cells are connected in series in a solar module

3. 600Volts, 5/7.6 Amps, 200 Watts PV system is used for all residential , commercial and industrial applications. The number of modules will vary based on the surface area

4. A power derating of 10-15% is applied to take account of power losses and conversion in-efficiencies of the inverter.

// References:

1. Photovoltaic Module Thermal/Wind performance: Long-term monitoring and Model development for energy rating , Solar program review meeting 2003, Govindswamy Tamizhmani et al

2. COMPARISON OF ENERGY PRODUCTION AND PERFORMANCE FROM FLAT-PLATE PHOTOVOLTAIC MODULE TECHNOLOGIES DEPLOYED AT FIXED TILT, J.A. del Cueto

3. Solar Collectors and Photovoltaic in energyPRO

4. Calculation of the polycrystalline PV module temperature using a simple method of energy balance

__

Inherits from: gld_object

__

Type: Instance (network topology element)

__

Note: Inherits from gld_object (not in generators module)

URI: glm:Solar

 classDiagram
    class Solar
    click Solar href "../Solar/"
      GlmObject <|-- Solar
        click GlmObject href "../GlmObject/"

      Solar : a_coeff

      Solar : ambient_temperature

      Solar : area

      Solar : b_coeff

      Solar : currTemp

      Solar : default_current_variable

      Solar : default_power_variable

      Solar : default_voltage_variable

      Solar : derating

      Solar : DOA_NR_ITERATIONS

      Solar : dT_coeff

      Solar : efficiency

      Solar : flags

      Solar : groupid

      Solar : I_Out

      Solar : in_svc

      Solar : Insolation

      Solar : last_DC_current

      Solar : last_DC_power

      Solar : latitude

      Solar : latitude_angle_fix

      Solar : longitude

      Solar : MAX_NR_ITERATIONS

      Solar : name

      Solar : NOCT

      Solar : orientation

      Solar : orientation_azimuth

      Solar : out_svc

      Solar : P_Out

      Solar : panel_type

      Solar : parent

      Solar : Pmax_temp_coeff

      Solar : prevTemp

      Solar : prevTime

      Solar : pvc_a1_inv_cels

      Solar : pvc_b1_inv_cels

      Solar : pvc_I_m_A

      Solar : pvc_I_sc_A

      Solar : pvc_Pmax_calc_simp_mode

      Solar : pvc_U_m_V

      Solar : pvc_U_oc_V

      Solar : rank

      Solar : Rated_Insolation

      Solar : rated_power

      Solar : Rinternal

      Solar : S_ref_wpm2

      Solar : shading_factor

      Solar : soiling

      Solar : SOLAR_POWER_MODEL

      Solar : SOLAR_TILT_MODEL

      Solar : T_coeff

      Solar : t_ref_cels

      Solar : Tambient

      Solar : Tcell

      Solar : tilt_angle

      Solar : Tmodule

      Solar : V_Max

      Solar : V_Out

      Solar : Voc

      Solar : Voc_Max

      Solar : Voc_temp_coeff

      Solar : weather

      Solar : wind_speed

      Solar : x0_root_rt

Inheritance

Slots

Name Cardinality and Range Description Inheritance
pvc_Pmax_calc_simp_mode 0..1
Boolean
If the simple mode is selected, the pvc_Pmax = pvc_U_m_V * pvc_I_m_A direct
t_ref_cels 0..1
Float
The referenced temperature direct
S_ref_wpm2 0..1
Float
The referenced insolation direct
pvc_a1_inv_cels 0..1
Float
In the calculation of dI, this is the coefficient that adjusts the difference... direct
pvc_b1_inv_cels 0..1
Float
In the calculation of dU, this is the coefficient that adjusts the difference... direct
pvc_U_oc_V 0..1
Float
The open circuit voltage direct
pvc_I_sc_A 0..1
Float
The short circuit current direct
pvc_U_m_V 0..1
Float
Voltage at maximum power point direct
pvc_I_m_A 0..1
Float
Current at maximum power point direct
MAX_NR_ITERATIONS 0..1
Integer
The allowed maximum number of newton-raphson itrations direct
x0_root_rt 0..1
Float
Set the initial guess at this extra percentage of the absolute x value at the... direct
DOA_NR_ITERATIONS 0..1
Float
Set the degree of accuracy of newton-raphson method direct
panel_type 0..1
String
direct
SOLAR_TILT_MODEL 0..1
String
solar tilt model used to compute insolation values direct
SOLAR_POWER_MODEL 0..1
String
direct
a_coeff 0..1
Float
a coefficient for module temperature correction formula direct
b_coeff 0..1
Float
b coefficient for module temperature correction formula direct
dT_coeff 0..1
Float
Temperature difference coefficient for module temperature correction formula direct
T_coeff 0..1
Float
Maximum power temperature coefficient for module temperature correction formu... direct
NOCT 0..1
Float
direct
Tmodule 0..1
Float
direct
Tambient 0..1
Float
direct
wind_speed 0..1
Float
direct
ambient_temperature 0..1
Float
Current ambient temperature of air direct
Insolation 0..1
Float
direct
Rinternal 0..1
Float
direct
Rated_Insolation 0..1
Float
direct
Pmax_temp_coeff 0..1
Float
direct
Voc_temp_coeff 0..1
Float
direct
V_Max 0..1
Float
direct
Voc_Max 0..1
Float
direct
Voc 0..1
Float
direct
efficiency 0..1
Float
direct
area 0..1
Float
direct
soiling 0..1
Float
Soiling of array factor - representing dirt on array direct
derating 0..1
Float
Panel derating to account for manufacturing variances direct
Tcell 0..1
Float
direct
rated_power 0..1
Float
Used to define the size of the solar panel in power rather than square footag... direct
P_Out 0..1
Float
direct
V_Out 0..1
Float
direct
I_Out 0..1
Float
direct
weather 0..1
String
direct
shading_factor 0..1
Float
Shading factor for scaling solar power to the array direct
tilt_angle 0..1
Float
Tilt angle of PV array direct
orientation_azimuth 0..1
Float
Facing direction of the PV array direct
latitude_angle_fix 0..1
Boolean
Fix tilt angle to installation latitude value direct
default_voltage_variable 0..1
Float
Accumulator/placeholder for default voltage value, when solar is run without ... direct
default_current_variable 0..1
Float
Accumulator/placeholder for default current value, when solar is run without ... direct
default_power_variable 0..1
Float
Accumulator/placeholder for default power value, when solar is run without an... direct
prevTemp 0..1
Float
CHECKPOINT_VAR: internal variable for prevTemp direct
currTemp 0..1
Float
CHECKPOINT_VAR: internal variable for currTemp direct
prevTime 0..1
String
CHECKPOINT_VAR: internal variable for prevTime direct
last_DC_current 0..1
Float
CHECKPOINT_VAR: internal variable for last_DC_current direct
last_DC_power 0..1
Float
CHECKPOINT_VAR: internal variable for last_DC_power direct
orientation 0..1
String
direct
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: PhotoVoltaicUnit, mRID _unit (inverter.cimtbl), its inverter's connection being the PowerElectronicsConnection, with SolarArrayInfo and SolarPanelInfo datasheets; name is PhotoVoltaicUnit.name. Export: each PhotoVoltaicUnit as the solar child of its inverter.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:Solar
native glm:Solar
exact cim:PhotoVoltaicUnit
close cim:SolarArrayInfo, cim:SolarPanelInfo

LinkML Source

Direct

name: solar
description: '// Assumptions:

  1. All solar panels are tilted as per the site latitude to perform at their best
  efficiency

  2. All the solar cells are connected in series in a solar module

  3. 600Volts, 5/7.6 Amps, 200 Watts PV system is used for all residential , commercial
  and industrial applications. The number of modules will vary based on the surface
  area

  4. A power derating of 10-15% is applied to take account of power losses and conversion
  in-efficiencies of the inverter.

  // References:

  1. Photovoltaic Module Thermal/Wind performance: Long-term monitoring and Model
  development for energy rating , Solar program review meeting 2003, Govindswamy Tamizhmani
  et al

  2. COMPARISON OF ENERGY PRODUCTION AND PERFORMANCE FROM FLAT-PLATE PHOTOVOLTAIC
  MODULE TECHNOLOGIES DEPLOYED AT FIXED TILT, J.A. del Cueto

  3. Solar Collectors and Photovoltaic in energyPRO

  4. Calculation of the polycrystalline PV module temperature using a simple method
  of energy balance


  Inherits from: gld_object


  Type: Instance (network topology element)


  Note: Inherits from gld_object (not in generators module)'
comments:
- 'Import: PhotoVoltaicUnit, mRID <connection>_unit (inverter.cimtbl), its inverter''s
  connection being the PowerElectronicsConnection, with SolarArrayInfo and SolarPanelInfo
  datasheets; name is PhotoVoltaicUnit.name. Export: each PhotoVoltaicUnit as the
  solar child of its inverter.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PhotoVoltaicUnit
close_mappings:
- cim:SolarArrayInfo
- cim:SolarPanelInfo
is_a: glm_object
attributes:
  pvc_Pmax_calc_simp_mode:
    name: pvc_Pmax_calc_simp_mode
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: pvc_Pmax_calc_simp_mode
    description: If the simple mode is selected, the pvc_Pmax = pvc_U_m_V * pvc_I_m_A.
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: boolean
    required: false
  t_ref_cels:
    name: t_ref_cels
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: t_ref_cels[degC]
    description: The referenced temperature
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degC
  S_ref_wpm2:
    name: S_ref_wpm2
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: S_ref_wpm2[W/m^2]
    description: The referenced insolation
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: W/m^2
  pvc_a1_inv_cels:
    name: pvc_a1_inv_cels
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_a1_inv_cels
    description: In the calculation of dI, this is the coefficient that adjusts the
      difference between t (temperature) and pvc_t_ref_cels (referenced temperature)
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  pvc_b1_inv_cels:
    name: pvc_b1_inv_cels
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_b1_inv_cels
    description: In the calculation of dU, this is the coefficient that adjusts the
      difference between t (temperature) and pvc_t_ref_cels (referenced temperature)
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  pvc_U_oc_V:
    name: pvc_U_oc_V
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_U_oc_V[V]
    description: The open circuit voltage
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  pvc_I_sc_A:
    name: pvc_I_sc_A
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_I_sc_A[A]
    description: The short circuit current
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: A
  pvc_U_m_V:
    name: pvc_U_m_V
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_U_m_V[V]
    description: Voltage at maximum power point
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  pvc_I_m_A:
    name: pvc_I_m_A
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_I_m_A[A]
    description: Current at maximum power point
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: A
  MAX_NR_ITERATIONS:
    name: MAX_NR_ITERATIONS
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: MAX_NR_ITERATIONS
    description: The allowed maximum number of newton-raphson itrations
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: integer
    required: false
  x0_root_rt:
    name: x0_root_rt
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: x0_root_rt
    description: Set the initial guess at this extra percentage of the absolute x
      value at the extreme point
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  DOA_NR_ITERATIONS:
    name: DOA_NR_ITERATIONS
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: DOA_NR_ITERATIONS
    description: Set the degree of accuracy of newton-raphson method
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  panel_type:
    name: panel_type
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: panel_type
    comments:
    - 'Import: sets the defaults of efficiency and Pmax_temp_coeff, so the output
      p; default SINGLE_CRYSTAL_SILICON. Export: unset.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    domain_of:
    - solar
    range: string
    required: false
  SOLAR_TILT_MODEL:
    name: SOLAR_TILT_MODEL
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: SOLAR_TILT_MODEL
    description: solar tilt model used to compute insolation values
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: string
    required: false
  SOLAR_POWER_MODEL:
    name: SOLAR_POWER_MODEL
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: SOLAR_POWER_MODEL
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: string
    required: false
  a_coeff:
    name: a_coeff
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: a_coeff
    description: a coefficient for module temperature correction formula
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  b_coeff:
    name: b_coeff
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b_coeff[s/m]
    description: b coefficient for module temperature correction formula
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: s/m
  dT_coeff:
    name: dT_coeff
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: dT_coeff[m*m*degC/kW]
    description: Temperature difference coefficient for module temperature correction
      formula
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: m*m*degC/kW
  T_coeff:
    name: T_coeff
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: T_coeff[%/degC]
    description: Maximum power temperature coefficient for module temperature correction
      formula
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: '%/degC'
  NOCT:
    name: NOCT
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: NOCT[degF]
    comments:
    - 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
      (W, load sign); it sets the module temperature; default 118.4 degF. Export:
      unset.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degF
  Tmodule:
    name: Tmodule
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tmodule[degF]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degF
  Tambient:
    name: Tambient
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tambient[degC]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degC
  wind_speed:
    name: wind_speed
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wind_speed[mph]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: mph
  ambient_temperature:
    name: ambient_temperature
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ambient_temperature[degF]
    description: Current ambient temperature of air
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    domain_of:
    - transformer
    - solar
    range: float
    required: false
    unit:
      ucum_code: degF
  Insolation:
    name: Insolation
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Insolation[W/sf]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: W/sf
  Rinternal:
    name: Rinternal
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rinternal[Ohm]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    domain_of:
    - battery
    - solar
    range: float
    required: false
    unit:
      ucum_code: Ohm
  Rated_Insolation:
    name: Rated_Insolation
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rated_Insolation[W/sf]
    comments:
    - 'Import: SolarPanelInfo.referenceIrradiation (W/m^2, from W/ft^2); irradiance
      = Rated_Insolation x shading_factor; default 92.902 W/sf (1000 W/m^2). Export:
      referenceIrradiation.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:SolarPanelInfo.referenceIrradiation
    - cim:PhotoVoltaicUnit.irradiance
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: W/sf
  Pmax_temp_coeff:
    name: Pmax_temp_coeff
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pmax_temp_coeff
    comments:
    - 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
      (W, load sign); per degF, default by panel_type. Export: unset.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  Voc_temp_coeff:
    name: Voc_temp_coeff
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Voc_temp_coeff
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  V_Max:
    name: V_Max
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_Max[V]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    domain_of:
    - battery
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  Voc_Max:
    name: Voc_Max
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Voc_Max[V]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  Voc:
    name: Voc
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Voc[V]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  efficiency:
    name: efficiency
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: efficiency[unit]
    comments:
    - 'Import: SolarPanelInfo.efficiency (percent); default by panel_type. Export:
      efficiency as a fraction.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:SolarPanelInfo.efficiency
    domain_of:
    - vfd
    - battery
    - diesel_dg
    - solar
    range: float
    required: false
    unit:
      ucum_code: unit
  area:
    name: area
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: area[sf]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: sf
  soiling:
    name: soiling
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: soiling[pu]
    description: Soiling of array factor - representing dirt on array
    comments:
    - 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
      (W, load sign); default 0.95; outside 0..1 raises. Export: 1.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: pu
  derating:
    name: derating
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: derating[pu]
    description: Panel derating to account for manufacturing variances
    comments:
    - 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
      (W, load sign); default 0.95; outside 0..1 raises. Export: p over GridLAB-D''s
      lossless output, the whole loss.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: pu
  Tcell:
    name: Tcell
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tcell[degC]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degC
  rated_power:
    name: rated_power
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: rated_power[W]
    description: Used to define the size of the solar panel in power rather than square
      footage.
    comments:
    - 'Import: PhotoVoltaicUnit.maxP (W), minP 0, and the DC output; unset raises.
      Export: maxP.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsUnit.maxP
    domain_of:
    - battery
    - inverter
    - inverter_dyn
    - solar
    range: float
    required: false
    unit:
      ucum_code: W
  P_Out:
    name: P_Out
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: P_Out[kW]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    domain_of:
    - inverter
    - solar
    range: float
    required: false
    unit:
      ucum_code: kW
  V_Out:
    name: V_Out
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_Out[V]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    domain_of:
    - battery
    - rectifier
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  I_Out:
    name: I_Out
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: I_Out[A]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    domain_of:
    - battery
    - rectifier
    - solar
    range: float
    required: false
    unit:
      ucum_code: A
  weather:
    name: weather
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: weather
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    domain_of:
    - pqload
    - solar
    - house
    range: string
    required: false
  shading_factor:
    name: shading_factor
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: shading_factor[pu]
    description: Shading factor for scaling solar power to the array
    comments:
    - 'Import: SolarArrayInfo.shadingFactor (percent) and a factor of the irradiance;
      default 1. Export: shadingFactor as a fraction.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:SolarArrayInfo.shadingFactor
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: pu
  tilt_angle:
    name: tilt_angle
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: tilt_angle[deg]
    description: Tilt angle of PV array
    comments:
    - 'Import: SolarArrayInfo.tiltAngle (deg); default 45. Export: tiltAngle.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    exact_mappings:
    - cim:SolarArrayInfo.tiltAngle
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: deg
  orientation_azimuth:
    name: orientation_azimuth
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: orientation_azimuth[deg]
    description: Facing direction of the PV array
    comments:
    - 'Import: SolarArrayInfo.orientationAzimuth (deg); default 180. Export: orientationAzimuth.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    exact_mappings:
    - cim:SolarArrayInfo.orientationAzimuth
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: deg
  latitude_angle_fix:
    name: latitude_angle_fix
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: latitude_angle_fix
    description: Fix tilt angle to installation latitude value
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: boolean
    required: false
  default_voltage_variable:
    name: default_voltage_variable
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: default_voltage_variable
    description: Accumulator/placeholder for default voltage value, when solar is
      run without an inverter
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  default_current_variable:
    name: default_current_variable
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: default_current_variable
    description: Accumulator/placeholder for default current value, when solar is
      run without an inverter
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  default_power_variable:
    name: default_power_variable
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: default_power_variable
    description: Accumulator/placeholder for default power value, when solar is run
      without an inverter
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  prevTemp:
    name: prevTemp
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: prevTemp
    description: 'CHECKPOINT_VAR: internal variable for prevTemp'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  currTemp:
    name: currTemp
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: currTemp
    description: 'CHECKPOINT_VAR: internal variable for currTemp'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  prevTime:
    name: prevTime
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: prevTime
    description: 'CHECKPOINT_VAR: internal variable for prevTime'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: string
    required: false
  last_DC_current:
    name: last_DC_current
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: last_DC_current
    description: 'CHECKPOINT_VAR: internal variable for last_DC_current'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  last_DC_power:
    name: last_DC_power
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: last_DC_power
    description: 'CHECKPOINT_VAR: internal variable for last_DC_power'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: float
    required: false
  orientation:
    name: orientation
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: orientation
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    domain_of:
    - solar
    range: string
    required: false

Induced

name: solar
description: '// Assumptions:

  1. All solar panels are tilted as per the site latitude to perform at their best
  efficiency

  2. All the solar cells are connected in series in a solar module

  3. 600Volts, 5/7.6 Amps, 200 Watts PV system is used for all residential , commercial
  and industrial applications. The number of modules will vary based on the surface
  area

  4. A power derating of 10-15% is applied to take account of power losses and conversion
  in-efficiencies of the inverter.

  // References:

  1. Photovoltaic Module Thermal/Wind performance: Long-term monitoring and Model
  development for energy rating , Solar program review meeting 2003, Govindswamy Tamizhmani
  et al

  2. COMPARISON OF ENERGY PRODUCTION AND PERFORMANCE FROM FLAT-PLATE PHOTOVOLTAIC
  MODULE TECHNOLOGIES DEPLOYED AT FIXED TILT, J.A. del Cueto

  3. Solar Collectors and Photovoltaic in energyPRO

  4. Calculation of the polycrystalline PV module temperature using a simple method
  of energy balance


  Inherits from: gld_object


  Type: Instance (network topology element)


  Note: Inherits from gld_object (not in generators module)'
comments:
- 'Import: PhotoVoltaicUnit, mRID <connection>_unit (inverter.cimtbl), its inverter''s
  connection being the PowerElectronicsConnection, with SolarArrayInfo and SolarPanelInfo
  datasheets; name is PhotoVoltaicUnit.name. Export: each PhotoVoltaicUnit as the
  solar child of its inverter.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PhotoVoltaicUnit
close_mappings:
- cim:SolarArrayInfo
- cim:SolarPanelInfo
is_a: glm_object
attributes:
  pvc_Pmax_calc_simp_mode:
    name: pvc_Pmax_calc_simp_mode
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: pvc_Pmax_calc_simp_mode
    description: If the simple mode is selected, the pvc_Pmax = pvc_U_m_V * pvc_I_m_A.
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: boolean
    required: false
  t_ref_cels:
    name: t_ref_cels
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: t_ref_cels[degC]
    description: The referenced temperature
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degC
  S_ref_wpm2:
    name: S_ref_wpm2
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: S_ref_wpm2[W/m^2]
    description: The referenced insolation
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: W/m^2
  pvc_a1_inv_cels:
    name: pvc_a1_inv_cels
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_a1_inv_cels
    description: In the calculation of dI, this is the coefficient that adjusts the
      difference between t (temperature) and pvc_t_ref_cels (referenced temperature)
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  pvc_b1_inv_cels:
    name: pvc_b1_inv_cels
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_b1_inv_cels
    description: In the calculation of dU, this is the coefficient that adjusts the
      difference between t (temperature) and pvc_t_ref_cels (referenced temperature)
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  pvc_U_oc_V:
    name: pvc_U_oc_V
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_U_oc_V[V]
    description: The open circuit voltage
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  pvc_I_sc_A:
    name: pvc_I_sc_A
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_I_sc_A[A]
    description: The short circuit current
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: A
  pvc_U_m_V:
    name: pvc_U_m_V
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_U_m_V[V]
    description: Voltage at maximum power point
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  pvc_I_m_A:
    name: pvc_I_m_A
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pvc_I_m_A[A]
    description: Current at maximum power point
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: A
  MAX_NR_ITERATIONS:
    name: MAX_NR_ITERATIONS
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: MAX_NR_ITERATIONS
    description: The allowed maximum number of newton-raphson itrations
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: integer
    required: false
  x0_root_rt:
    name: x0_root_rt
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: x0_root_rt
    description: Set the initial guess at this extra percentage of the absolute x
      value at the extreme point
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  DOA_NR_ITERATIONS:
    name: DOA_NR_ITERATIONS
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: DOA_NR_ITERATIONS
    description: Set the degree of accuracy of newton-raphson method
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  panel_type:
    name: panel_type
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: panel_type
    comments:
    - 'Import: sets the defaults of efficiency and Pmax_temp_coeff, so the output
      p; default SINGLE_CRYSTAL_SILICON. Export: unset.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: string
    required: false
  SOLAR_TILT_MODEL:
    name: SOLAR_TILT_MODEL
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: SOLAR_TILT_MODEL
    description: solar tilt model used to compute insolation values
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: string
    required: false
  SOLAR_POWER_MODEL:
    name: SOLAR_POWER_MODEL
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: SOLAR_POWER_MODEL
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: string
    required: false
  a_coeff:
    name: a_coeff
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: a_coeff
    description: a coefficient for module temperature correction formula
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  b_coeff:
    name: b_coeff
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b_coeff[s/m]
    description: b coefficient for module temperature correction formula
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: s/m
  dT_coeff:
    name: dT_coeff
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: dT_coeff[m*m*degC/kW]
    description: Temperature difference coefficient for module temperature correction
      formula
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: m*m*degC/kW
  T_coeff:
    name: T_coeff
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: T_coeff[%/degC]
    description: Maximum power temperature coefficient for module temperature correction
      formula
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: '%/degC'
  NOCT:
    name: NOCT
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: NOCT[degF]
    comments:
    - 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
      (W, load sign); it sets the module temperature; default 118.4 degF. Export:
      unset.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degF
  Tmodule:
    name: Tmodule
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tmodule[degF]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degF
  Tambient:
    name: Tambient
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tambient[degC]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degC
  wind_speed:
    name: wind_speed
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: wind_speed[mph]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    - windturb_dg
    range: float
    required: false
    unit:
      ucum_code: mph
  ambient_temperature:
    name: ambient_temperature
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ambient_temperature[degF]
    description: Current ambient temperature of air
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    owner: solar
    domain_of:
    - transformer
    - solar
    range: float
    required: false
    unit:
      ucum_code: degF
  Insolation:
    name: Insolation
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Insolation[W/sf]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: W/sf
  Rinternal:
    name: Rinternal
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rinternal[Ohm]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    owner: solar
    domain_of:
    - battery
    - solar
    range: float
    required: false
    unit:
      ucum_code: Ohm
  Rated_Insolation:
    name: Rated_Insolation
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Rated_Insolation[W/sf]
    comments:
    - 'Import: SolarPanelInfo.referenceIrradiation (W/m^2, from W/ft^2); irradiance
      = Rated_Insolation x shading_factor; default 92.902 W/sf (1000 W/m^2). Export:
      referenceIrradiation.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:SolarPanelInfo.referenceIrradiation
    - cim:PhotoVoltaicUnit.irradiance
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: W/sf
  Pmax_temp_coeff:
    name: Pmax_temp_coeff
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pmax_temp_coeff
    comments:
    - 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
      (W, load sign); per degF, default by panel_type. Export: unset.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  Voc_temp_coeff:
    name: Voc_temp_coeff
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Voc_temp_coeff
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  V_Max:
    name: V_Max
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_Max[V]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    owner: solar
    domain_of:
    - battery
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  Voc_Max:
    name: Voc_Max
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Voc_Max[V]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  Voc:
    name: Voc
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Voc[V]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  efficiency:
    name: efficiency
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: efficiency[unit]
    comments:
    - 'Import: SolarPanelInfo.efficiency (percent); default by panel_type. Export:
      efficiency as a fraction.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:SolarPanelInfo.efficiency
    owner: solar
    domain_of:
    - vfd
    - battery
    - diesel_dg
    - solar
    range: float
    required: false
    unit:
      ucum_code: unit
  area:
    name: area
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: area[sf]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: sf
  soiling:
    name: soiling
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: soiling[pu]
    description: Soiling of array factor - representing dirt on array
    comments:
    - 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
      (W, load sign); default 0.95; outside 0..1 raises. Export: 1.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: pu
  derating:
    name: derating
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: derating[pu]
    description: Panel derating to account for manufacturing variances
    comments:
    - 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
      (W, load sign); default 0.95; outside 0..1 raises. Export: p over GridLAB-D''s
      lossless output, the whole loss.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: pu
  Tcell:
    name: Tcell
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tcell[degC]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: degC
  rated_power:
    name: rated_power
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: rated_power[W]
    description: Used to define the size of the solar panel in power rather than square
      footage.
    comments:
    - 'Import: PhotoVoltaicUnit.maxP (W), minP 0, and the DC output; unset raises.
      Export: maxP.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:PowerElectronicsUnit.maxP
    owner: solar
    domain_of:
    - battery
    - inverter
    - inverter_dyn
    - solar
    range: float
    required: false
    unit:
      ucum_code: W
  P_Out:
    name: P_Out
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: P_Out[kW]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    owner: solar
    domain_of:
    - inverter
    - solar
    range: float
    required: false
    unit:
      ucum_code: kW
  V_Out:
    name: V_Out
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_Out[V]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    owner: solar
    domain_of:
    - battery
    - rectifier
    - solar
    range: float
    required: false
    unit:
      ucum_code: V
  I_Out:
    name: I_Out
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: I_Out[A]
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    owner: solar
    domain_of:
    - battery
    - rectifier
    - solar
    range: float
    required: false
    unit:
      ucum_code: A
  weather:
    name: weather
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: weather
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    owner: solar
    domain_of:
    - pqload
    - solar
    - house
    range: string
    required: false
  shading_factor:
    name: shading_factor
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: shading_factor[pu]
    description: Shading factor for scaling solar power to the array
    comments:
    - 'Import: SolarArrayInfo.shadingFactor (percent) and a factor of the irradiance;
      default 1. Export: shadingFactor as a fraction.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    close_mappings:
    - cim:SolarArrayInfo.shadingFactor
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: pu
  tilt_angle:
    name: tilt_angle
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: tilt_angle[deg]
    description: Tilt angle of PV array
    comments:
    - 'Import: SolarArrayInfo.tiltAngle (deg); default 45. Export: tiltAngle.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    exact_mappings:
    - cim:SolarArrayInfo.tiltAngle
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: deg
  orientation_azimuth:
    name: orientation_azimuth
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: orientation_azimuth[deg]
    description: Facing direction of the PV array
    comments:
    - 'Import: SolarArrayInfo.orientationAzimuth (deg); default 180. Export: orientationAzimuth.'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    exact_mappings:
    - cim:SolarArrayInfo.orientationAzimuth
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
    unit:
      ucum_code: deg
  latitude_angle_fix:
    name: latitude_angle_fix
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: latitude_angle_fix
    description: Fix tilt angle to installation latitude value
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: boolean
    required: false
  default_voltage_variable:
    name: default_voltage_variable
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: default_voltage_variable
    description: Accumulator/placeholder for default voltage value, when solar is
      run without an inverter
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  default_current_variable:
    name: default_current_variable
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: default_current_variable
    description: Accumulator/placeholder for default current value, when solar is
      run without an inverter
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  default_power_variable:
    name: default_power_variable
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: default_power_variable
    description: Accumulator/placeholder for default power value, when solar is run
      without an inverter
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  prevTemp:
    name: prevTemp
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: prevTemp
    description: 'CHECKPOINT_VAR: internal variable for prevTemp'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  currTemp:
    name: currTemp
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: currTemp
    description: 'CHECKPOINT_VAR: internal variable for currTemp'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  prevTime:
    name: prevTime
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: prevTime
    description: 'CHECKPOINT_VAR: internal variable for prevTime'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: string
    required: false
  last_DC_current:
    name: last_DC_current
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: last_DC_current
    description: 'CHECKPOINT_VAR: internal variable for last_DC_current'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  last_DC_power:
    name: last_DC_power
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: last_DC_power
    description: 'CHECKPOINT_VAR: internal variable for last_DC_power'
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: float
    required: false
  orientation:
    name: orientation
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: orientation
    from_schema: https://gridlabd.org/schema/glm/generators/solar
    rank: 1000
    owner: solar
    domain_of:
    - solar
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: solar
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: solar
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: solar
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: solar
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: solar
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: solar
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: solar
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: solar
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: solar
    domain_of:
    - glm_object
    range: string