Class: Solar¶
// Assumptions:
1. All solar panels are tilted as per the site latitude to perform at their best efficiency
2. All the solar cells are connected in series in a solar module
3. 600Volts, 5/7.6 Amps, 200 Watts PV system is used for all residential , commercial and industrial applications. The number of modules will vary based on the surface area
4. A power derating of 10-15% is applied to take account of power losses and conversion in-efficiencies of the inverter.
// References:
1. Photovoltaic Module Thermal/Wind performance: Long-term monitoring and Model development for energy rating , Solar program review meeting 2003, Govindswamy Tamizhmani et al
2. COMPARISON OF ENERGY PRODUCTION AND PERFORMANCE FROM FLAT-PLATE PHOTOVOLTAIC MODULE TECHNOLOGIES DEPLOYED AT FIXED TILT, J.A. del Cueto
3. Solar Collectors and Photovoltaic in energyPRO
4. Calculation of the polycrystalline PV module temperature using a simple method of energy balance
__
Inherits from: gld_object
__
Type: Instance (network topology element)
__
Note: Inherits from gld_object (not in generators module)
URI: glm:Solar
classDiagram
class Solar
click Solar href "../Solar/"
GlmObject <|-- Solar
click GlmObject href "../GlmObject/"
Solar : a_coeff
Solar : ambient_temperature
Solar : area
Solar : b_coeff
Solar : currTemp
Solar : default_current_variable
Solar : default_power_variable
Solar : default_voltage_variable
Solar : derating
Solar : DOA_NR_ITERATIONS
Solar : dT_coeff
Solar : efficiency
Solar : flags
Solar : groupid
Solar : I_Out
Solar : in_svc
Solar : Insolation
Solar : last_DC_current
Solar : last_DC_power
Solar : latitude
Solar : latitude_angle_fix
Solar : longitude
Solar : MAX_NR_ITERATIONS
Solar : name
Solar : NOCT
Solar : orientation
Solar : orientation_azimuth
Solar : out_svc
Solar : P_Out
Solar : panel_type
Solar : parent
Solar : Pmax_temp_coeff
Solar : prevTemp
Solar : prevTime
Solar : pvc_a1_inv_cels
Solar : pvc_b1_inv_cels
Solar : pvc_I_m_A
Solar : pvc_I_sc_A
Solar : pvc_Pmax_calc_simp_mode
Solar : pvc_U_m_V
Solar : pvc_U_oc_V
Solar : rank
Solar : Rated_Insolation
Solar : rated_power
Solar : Rinternal
Solar : S_ref_wpm2
Solar : shading_factor
Solar : soiling
Solar : SOLAR_POWER_MODEL
Solar : SOLAR_TILT_MODEL
Solar : T_coeff
Solar : t_ref_cels
Solar : Tambient
Solar : Tcell
Solar : tilt_angle
Solar : Tmodule
Solar : V_Max
Solar : V_Out
Solar : Voc
Solar : Voc_Max
Solar : Voc_temp_coeff
Solar : weather
Solar : wind_speed
Solar : x0_root_rt
Inheritance¶
- GlmObject
- Solar
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| pvc_Pmax_calc_simp_mode | 0..1 Boolean |
If the simple mode is selected, the pvc_Pmax = pvc_U_m_V * pvc_I_m_A | direct |
| t_ref_cels | 0..1 Float |
The referenced temperature | direct |
| S_ref_wpm2 | 0..1 Float |
The referenced insolation | direct |
| pvc_a1_inv_cels | 0..1 Float |
In the calculation of dI, this is the coefficient that adjusts the difference... | direct |
| pvc_b1_inv_cels | 0..1 Float |
In the calculation of dU, this is the coefficient that adjusts the difference... | direct |
| pvc_U_oc_V | 0..1 Float |
The open circuit voltage | direct |
| pvc_I_sc_A | 0..1 Float |
The short circuit current | direct |
| pvc_U_m_V | 0..1 Float |
Voltage at maximum power point | direct |
| pvc_I_m_A | 0..1 Float |
Current at maximum power point | direct |
| MAX_NR_ITERATIONS | 0..1 Integer |
The allowed maximum number of newton-raphson itrations | direct |
| x0_root_rt | 0..1 Float |
Set the initial guess at this extra percentage of the absolute x value at the... | direct |
| DOA_NR_ITERATIONS | 0..1 Float |
Set the degree of accuracy of newton-raphson method | direct |
| panel_type | 0..1 String |
direct | |
| SOLAR_TILT_MODEL | 0..1 String |
solar tilt model used to compute insolation values | direct |
| SOLAR_POWER_MODEL | 0..1 String |
direct | |
| a_coeff | 0..1 Float |
a coefficient for module temperature correction formula | direct |
| b_coeff | 0..1 Float |
b coefficient for module temperature correction formula | direct |
| dT_coeff | 0..1 Float |
Temperature difference coefficient for module temperature correction formula | direct |
| T_coeff | 0..1 Float |
Maximum power temperature coefficient for module temperature correction formu... | direct |
| NOCT | 0..1 Float |
direct | |
| Tmodule | 0..1 Float |
direct | |
| Tambient | 0..1 Float |
direct | |
| wind_speed | 0..1 Float |
direct | |
| ambient_temperature | 0..1 Float |
Current ambient temperature of air | direct |
| Insolation | 0..1 Float |
direct | |
| Rinternal | 0..1 Float |
direct | |
| Rated_Insolation | 0..1 Float |
direct | |
| Pmax_temp_coeff | 0..1 Float |
direct | |
| Voc_temp_coeff | 0..1 Float |
direct | |
| V_Max | 0..1 Float |
direct | |
| Voc_Max | 0..1 Float |
direct | |
| Voc | 0..1 Float |
direct | |
| efficiency | 0..1 Float |
direct | |
| area | 0..1 Float |
direct | |
| soiling | 0..1 Float |
Soiling of array factor - representing dirt on array | direct |
| derating | 0..1 Float |
Panel derating to account for manufacturing variances | direct |
| Tcell | 0..1 Float |
direct | |
| rated_power | 0..1 Float |
Used to define the size of the solar panel in power rather than square footag... | direct |
| P_Out | 0..1 Float |
direct | |
| V_Out | 0..1 Float |
direct | |
| I_Out | 0..1 Float |
direct | |
| weather | 0..1 String |
direct | |
| shading_factor | 0..1 Float |
Shading factor for scaling solar power to the array | direct |
| tilt_angle | 0..1 Float |
Tilt angle of PV array | direct |
| orientation_azimuth | 0..1 Float |
Facing direction of the PV array | direct |
| latitude_angle_fix | 0..1 Boolean |
Fix tilt angle to installation latitude value | direct |
| default_voltage_variable | 0..1 Float |
Accumulator/placeholder for default voltage value, when solar is run without ... | direct |
| default_current_variable | 0..1 Float |
Accumulator/placeholder for default current value, when solar is run without ... | direct |
| default_power_variable | 0..1 Float |
Accumulator/placeholder for default power value, when solar is run without an... | direct |
| prevTemp | 0..1 Float |
CHECKPOINT_VAR: internal variable for prevTemp | direct |
| currTemp | 0..1 Float |
CHECKPOINT_VAR: internal variable for currTemp | direct |
| prevTime | 0..1 String |
CHECKPOINT_VAR: internal variable for prevTime | direct |
| last_DC_current | 0..1 Float |
CHECKPOINT_VAR: internal variable for last_DC_current | direct |
| last_DC_power | 0..1 Float |
CHECKPOINT_VAR: internal variable for last_DC_power | direct |
| orientation | 0..1 String |
direct | |
| name | 1 String |
The object's name; unique across the model | GlmObject |
| parent | 0..1 String |
The parent object's name | GlmObject |
| groupid | 0..1 String |
Free-text group label | GlmObject |
| latitude | 0..1 String |
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) | GlmObject |
| longitude | 0..1 String |
Longitude, as written | GlmObject |
| in_svc | 0..1 String |
Timestamp the object enters service | GlmObject |
| out_svc | 0..1 String |
Timestamp the object leaves service | GlmObject |
| rank | 0..1 String |
Solver rank | GlmObject |
| flags | 0..1 String |
Core object flags | GlmObject |
Comments¶
- Import: PhotoVoltaicUnit, mRID
_unit (inverter.cimtbl), its inverter's connection being the PowerElectronicsConnection, with SolarArrayInfo and SolarPanelInfo datasheets; name is PhotoVoltaicUnit.name. Export: each PhotoVoltaicUnit as the solar child of its inverter.
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridlabd.org/schema/glm
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | glm:Solar |
| native | glm:Solar |
| exact | cim:PhotoVoltaicUnit |
| close | cim:SolarArrayInfo, cim:SolarPanelInfo |
LinkML Source¶
Direct¶
name: solar
description: '// Assumptions:
1. All solar panels are tilted as per the site latitude to perform at their best
efficiency
2. All the solar cells are connected in series in a solar module
3. 600Volts, 5/7.6 Amps, 200 Watts PV system is used for all residential , commercial
and industrial applications. The number of modules will vary based on the surface
area
4. A power derating of 10-15% is applied to take account of power losses and conversion
in-efficiencies of the inverter.
// References:
1. Photovoltaic Module Thermal/Wind performance: Long-term monitoring and Model
development for energy rating , Solar program review meeting 2003, Govindswamy Tamizhmani
et al
2. COMPARISON OF ENERGY PRODUCTION AND PERFORMANCE FROM FLAT-PLATE PHOTOVOLTAIC
MODULE TECHNOLOGIES DEPLOYED AT FIXED TILT, J.A. del Cueto
3. Solar Collectors and Photovoltaic in energyPRO
4. Calculation of the polycrystalline PV module temperature using a simple method
of energy balance
Inherits from: gld_object
Type: Instance (network topology element)
Note: Inherits from gld_object (not in generators module)'
comments:
- 'Import: PhotoVoltaicUnit, mRID <connection>_unit (inverter.cimtbl), its inverter''s
connection being the PowerElectronicsConnection, with SolarArrayInfo and SolarPanelInfo
datasheets; name is PhotoVoltaicUnit.name. Export: each PhotoVoltaicUnit as the
solar child of its inverter.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PhotoVoltaicUnit
close_mappings:
- cim:SolarArrayInfo
- cim:SolarPanelInfo
is_a: glm_object
attributes:
pvc_Pmax_calc_simp_mode:
name: pvc_Pmax_calc_simp_mode
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: pvc_Pmax_calc_simp_mode
description: If the simple mode is selected, the pvc_Pmax = pvc_U_m_V * pvc_I_m_A.
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: boolean
required: false
t_ref_cels:
name: t_ref_cels
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: t_ref_cels[degC]
description: The referenced temperature
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degC
S_ref_wpm2:
name: S_ref_wpm2
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: S_ref_wpm2[W/m^2]
description: The referenced insolation
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: W/m^2
pvc_a1_inv_cels:
name: pvc_a1_inv_cels
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_a1_inv_cels
description: In the calculation of dI, this is the coefficient that adjusts the
difference between t (temperature) and pvc_t_ref_cels (referenced temperature)
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
pvc_b1_inv_cels:
name: pvc_b1_inv_cels
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_b1_inv_cels
description: In the calculation of dU, this is the coefficient that adjusts the
difference between t (temperature) and pvc_t_ref_cels (referenced temperature)
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
pvc_U_oc_V:
name: pvc_U_oc_V
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_U_oc_V[V]
description: The open circuit voltage
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: V
pvc_I_sc_A:
name: pvc_I_sc_A
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_I_sc_A[A]
description: The short circuit current
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: A
pvc_U_m_V:
name: pvc_U_m_V
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_U_m_V[V]
description: Voltage at maximum power point
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: V
pvc_I_m_A:
name: pvc_I_m_A
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_I_m_A[A]
description: Current at maximum power point
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: A
MAX_NR_ITERATIONS:
name: MAX_NR_ITERATIONS
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: MAX_NR_ITERATIONS
description: The allowed maximum number of newton-raphson itrations
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: integer
required: false
x0_root_rt:
name: x0_root_rt
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: x0_root_rt
description: Set the initial guess at this extra percentage of the absolute x
value at the extreme point
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
DOA_NR_ITERATIONS:
name: DOA_NR_ITERATIONS
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: DOA_NR_ITERATIONS
description: Set the degree of accuracy of newton-raphson method
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
panel_type:
name: panel_type
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: panel_type
comments:
- 'Import: sets the defaults of efficiency and Pmax_temp_coeff, so the output
p; default SINGLE_CRYSTAL_SILICON. Export: unset.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
domain_of:
- solar
range: string
required: false
SOLAR_TILT_MODEL:
name: SOLAR_TILT_MODEL
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: SOLAR_TILT_MODEL
description: solar tilt model used to compute insolation values
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: string
required: false
SOLAR_POWER_MODEL:
name: SOLAR_POWER_MODEL
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: SOLAR_POWER_MODEL
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: string
required: false
a_coeff:
name: a_coeff
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: a_coeff
description: a coefficient for module temperature correction formula
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
b_coeff:
name: b_coeff
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: b_coeff[s/m]
description: b coefficient for module temperature correction formula
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: s/m
dT_coeff:
name: dT_coeff
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: dT_coeff[m*m*degC/kW]
description: Temperature difference coefficient for module temperature correction
formula
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: m*m*degC/kW
T_coeff:
name: T_coeff
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: T_coeff[%/degC]
description: Maximum power temperature coefficient for module temperature correction
formula
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: '%/degC'
NOCT:
name: NOCT
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: NOCT[degF]
comments:
- 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
(W, load sign); it sets the module temperature; default 118.4 degF. Export:
unset.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degF
Tmodule:
name: Tmodule
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tmodule[degF]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degF
Tambient:
name: Tambient
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tambient[degC]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degC
wind_speed:
name: wind_speed
annotations:
order:
tag: order
value: 23
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: wind_speed[mph]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
- windturb_dg
range: float
required: false
unit:
ucum_code: mph
ambient_temperature:
name: ambient_temperature
annotations:
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: ambient_temperature[degF]
description: Current ambient temperature of air
from_schema: https://gridlabd.org/schema/glm/generators/solar
domain_of:
- transformer
- solar
range: float
required: false
unit:
ucum_code: degF
Insolation:
name: Insolation
annotations:
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Insolation[W/sf]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: W/sf
Rinternal:
name: Rinternal
annotations:
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rinternal[Ohm]
from_schema: https://gridlabd.org/schema/glm/generators/solar
domain_of:
- battery
- solar
range: float
required: false
unit:
ucum_code: Ohm
Rated_Insolation:
name: Rated_Insolation
annotations:
order:
tag: order
value: 27
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rated_Insolation[W/sf]
comments:
- 'Import: SolarPanelInfo.referenceIrradiation (W/m^2, from W/ft^2); irradiance
= Rated_Insolation x shading_factor; default 92.902 W/sf (1000 W/m^2). Export:
referenceIrradiation.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:SolarPanelInfo.referenceIrradiation
- cim:PhotoVoltaicUnit.irradiance
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: W/sf
Pmax_temp_coeff:
name: Pmax_temp_coeff
annotations:
order:
tag: order
value: 28
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pmax_temp_coeff
comments:
- 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
(W, load sign); per degF, default by panel_type. Export: unset.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
domain_of:
- solar
range: float
required: false
Voc_temp_coeff:
name: Voc_temp_coeff
annotations:
order:
tag: order
value: 29
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Voc_temp_coeff
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
V_Max:
name: V_Max
annotations:
order:
tag: order
value: 30
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_Max[V]
from_schema: https://gridlabd.org/schema/glm/generators/solar
domain_of:
- battery
- solar
range: float
required: false
unit:
ucum_code: V
Voc_Max:
name: Voc_Max
annotations:
order:
tag: order
value: 31
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Voc_Max[V]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: V
Voc:
name: Voc
annotations:
order:
tag: order
value: 32
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Voc[V]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: V
efficiency:
name: efficiency
annotations:
order:
tag: order
value: 33
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: efficiency[unit]
comments:
- 'Import: SolarPanelInfo.efficiency (percent); default by panel_type. Export:
efficiency as a fraction.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:SolarPanelInfo.efficiency
domain_of:
- vfd
- battery
- diesel_dg
- solar
range: float
required: false
unit:
ucum_code: unit
area:
name: area
annotations:
order:
tag: order
value: 34
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: area[sf]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: sf
soiling:
name: soiling
annotations:
order:
tag: order
value: 35
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: soiling[pu]
description: Soiling of array factor - representing dirt on array
comments:
- 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
(W, load sign); default 0.95; outside 0..1 raises. Export: 1.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: pu
derating:
name: derating
annotations:
order:
tag: order
value: 36
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: derating[pu]
description: Panel derating to account for manufacturing variances
comments:
- 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
(W, load sign); default 0.95; outside 0..1 raises. Export: p over GridLAB-D''s
lossless output, the whole loss.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: pu
Tcell:
name: Tcell
annotations:
order:
tag: order
value: 37
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tcell[degC]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degC
rated_power:
name: rated_power
annotations:
order:
tag: order
value: 38
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: rated_power[W]
description: Used to define the size of the solar panel in power rather than square
footage.
comments:
- 'Import: PhotoVoltaicUnit.maxP (W), minP 0, and the DC output; unset raises.
Export: maxP.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsUnit.maxP
domain_of:
- battery
- inverter
- inverter_dyn
- solar
range: float
required: false
unit:
ucum_code: W
P_Out:
name: P_Out
annotations:
order:
tag: order
value: 39
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: P_Out[kW]
from_schema: https://gridlabd.org/schema/glm/generators/solar
domain_of:
- inverter
- solar
range: float
required: false
unit:
ucum_code: kW
V_Out:
name: V_Out
annotations:
order:
tag: order
value: 40
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_Out[V]
from_schema: https://gridlabd.org/schema/glm/generators/solar
domain_of:
- battery
- rectifier
- solar
range: float
required: false
unit:
ucum_code: V
I_Out:
name: I_Out
annotations:
order:
tag: order
value: 41
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: I_Out[A]
from_schema: https://gridlabd.org/schema/glm/generators/solar
domain_of:
- battery
- rectifier
- solar
range: float
required: false
unit:
ucum_code: A
weather:
name: weather
annotations:
order:
tag: order
value: 42
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: weather
from_schema: https://gridlabd.org/schema/glm/generators/solar
domain_of:
- pqload
- solar
- house
range: string
required: false
shading_factor:
name: shading_factor
annotations:
order:
tag: order
value: 43
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: shading_factor[pu]
description: Shading factor for scaling solar power to the array
comments:
- 'Import: SolarArrayInfo.shadingFactor (percent) and a factor of the irradiance;
default 1. Export: shadingFactor as a fraction.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:SolarArrayInfo.shadingFactor
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: pu
tilt_angle:
name: tilt_angle
annotations:
order:
tag: order
value: 44
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: tilt_angle[deg]
description: Tilt angle of PV array
comments:
- 'Import: SolarArrayInfo.tiltAngle (deg); default 45. Export: tiltAngle.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
exact_mappings:
- cim:SolarArrayInfo.tiltAngle
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: deg
orientation_azimuth:
name: orientation_azimuth
annotations:
order:
tag: order
value: 45
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: orientation_azimuth[deg]
description: Facing direction of the PV array
comments:
- 'Import: SolarArrayInfo.orientationAzimuth (deg); default 180. Export: orientationAzimuth.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
exact_mappings:
- cim:SolarArrayInfo.orientationAzimuth
rank: 1000
domain_of:
- solar
range: float
required: false
unit:
ucum_code: deg
latitude_angle_fix:
name: latitude_angle_fix
annotations:
order:
tag: order
value: 46
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: latitude_angle_fix
description: Fix tilt angle to installation latitude value
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: boolean
required: false
default_voltage_variable:
name: default_voltage_variable
annotations:
order:
tag: order
value: 47
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: default_voltage_variable
description: Accumulator/placeholder for default voltage value, when solar is
run without an inverter
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
default_current_variable:
name: default_current_variable
annotations:
order:
tag: order
value: 48
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: default_current_variable
description: Accumulator/placeholder for default current value, when solar is
run without an inverter
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
default_power_variable:
name: default_power_variable
annotations:
order:
tag: order
value: 49
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: default_power_variable
description: Accumulator/placeholder for default power value, when solar is run
without an inverter
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
prevTemp:
name: prevTemp
annotations:
order:
tag: order
value: 50
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: prevTemp
description: 'CHECKPOINT_VAR: internal variable for prevTemp'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
currTemp:
name: currTemp
annotations:
order:
tag: order
value: 51
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: currTemp
description: 'CHECKPOINT_VAR: internal variable for currTemp'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
prevTime:
name: prevTime
annotations:
order:
tag: order
value: 52
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: prevTime
description: 'CHECKPOINT_VAR: internal variable for prevTime'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: string
required: false
last_DC_current:
name: last_DC_current
annotations:
order:
tag: order
value: 53
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: last_DC_current
description: 'CHECKPOINT_VAR: internal variable for last_DC_current'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
last_DC_power:
name: last_DC_power
annotations:
order:
tag: order
value: 54
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: last_DC_power
description: 'CHECKPOINT_VAR: internal variable for last_DC_power'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: float
required: false
orientation:
name: orientation
annotations:
order:
tag: order
value: 55
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: orientation
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
domain_of:
- solar
range: string
required: false
Induced¶
name: solar
description: '// Assumptions:
1. All solar panels are tilted as per the site latitude to perform at their best
efficiency
2. All the solar cells are connected in series in a solar module
3. 600Volts, 5/7.6 Amps, 200 Watts PV system is used for all residential , commercial
and industrial applications. The number of modules will vary based on the surface
area
4. A power derating of 10-15% is applied to take account of power losses and conversion
in-efficiencies of the inverter.
// References:
1. Photovoltaic Module Thermal/Wind performance: Long-term monitoring and Model
development for energy rating , Solar program review meeting 2003, Govindswamy Tamizhmani
et al
2. COMPARISON OF ENERGY PRODUCTION AND PERFORMANCE FROM FLAT-PLATE PHOTOVOLTAIC
MODULE TECHNOLOGIES DEPLOYED AT FIXED TILT, J.A. del Cueto
3. Solar Collectors and Photovoltaic in energyPRO
4. Calculation of the polycrystalline PV module temperature using a simple method
of energy balance
Inherits from: gld_object
Type: Instance (network topology element)
Note: Inherits from gld_object (not in generators module)'
comments:
- 'Import: PhotoVoltaicUnit, mRID <connection>_unit (inverter.cimtbl), its inverter''s
connection being the PowerElectronicsConnection, with SolarArrayInfo and SolarPanelInfo
datasheets; name is PhotoVoltaicUnit.name. Export: each PhotoVoltaicUnit as the
solar child of its inverter.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PhotoVoltaicUnit
close_mappings:
- cim:SolarArrayInfo
- cim:SolarPanelInfo
is_a: glm_object
attributes:
pvc_Pmax_calc_simp_mode:
name: pvc_Pmax_calc_simp_mode
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: pvc_Pmax_calc_simp_mode
description: If the simple mode is selected, the pvc_Pmax = pvc_U_m_V * pvc_I_m_A.
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: boolean
required: false
t_ref_cels:
name: t_ref_cels
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: t_ref_cels[degC]
description: The referenced temperature
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degC
S_ref_wpm2:
name: S_ref_wpm2
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: S_ref_wpm2[W/m^2]
description: The referenced insolation
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: W/m^2
pvc_a1_inv_cels:
name: pvc_a1_inv_cels
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_a1_inv_cels
description: In the calculation of dI, this is the coefficient that adjusts the
difference between t (temperature) and pvc_t_ref_cels (referenced temperature)
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
pvc_b1_inv_cels:
name: pvc_b1_inv_cels
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_b1_inv_cels
description: In the calculation of dU, this is the coefficient that adjusts the
difference between t (temperature) and pvc_t_ref_cels (referenced temperature)
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
pvc_U_oc_V:
name: pvc_U_oc_V
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_U_oc_V[V]
description: The open circuit voltage
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: V
pvc_I_sc_A:
name: pvc_I_sc_A
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_I_sc_A[A]
description: The short circuit current
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: A
pvc_U_m_V:
name: pvc_U_m_V
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_U_m_V[V]
description: Voltage at maximum power point
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: V
pvc_I_m_A:
name: pvc_I_m_A
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pvc_I_m_A[A]
description: Current at maximum power point
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: A
MAX_NR_ITERATIONS:
name: MAX_NR_ITERATIONS
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: MAX_NR_ITERATIONS
description: The allowed maximum number of newton-raphson itrations
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: integer
required: false
x0_root_rt:
name: x0_root_rt
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: x0_root_rt
description: Set the initial guess at this extra percentage of the absolute x
value at the extreme point
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
DOA_NR_ITERATIONS:
name: DOA_NR_ITERATIONS
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: DOA_NR_ITERATIONS
description: Set the degree of accuracy of newton-raphson method
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
panel_type:
name: panel_type
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: panel_type
comments:
- 'Import: sets the defaults of efficiency and Pmax_temp_coeff, so the output
p; default SINGLE_CRYSTAL_SILICON. Export: unset.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
owner: solar
domain_of:
- solar
range: string
required: false
SOLAR_TILT_MODEL:
name: SOLAR_TILT_MODEL
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: SOLAR_TILT_MODEL
description: solar tilt model used to compute insolation values
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: string
required: false
SOLAR_POWER_MODEL:
name: SOLAR_POWER_MODEL
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: SOLAR_POWER_MODEL
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: string
required: false
a_coeff:
name: a_coeff
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: a_coeff
description: a coefficient for module temperature correction formula
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
b_coeff:
name: b_coeff
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: b_coeff[s/m]
description: b coefficient for module temperature correction formula
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: s/m
dT_coeff:
name: dT_coeff
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: dT_coeff[m*m*degC/kW]
description: Temperature difference coefficient for module temperature correction
formula
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: m*m*degC/kW
T_coeff:
name: T_coeff
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: T_coeff[%/degC]
description: Maximum power temperature coefficient for module temperature correction
formula
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: '%/degC'
NOCT:
name: NOCT
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: NOCT[degF]
comments:
- 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
(W, load sign); it sets the module temperature; default 118.4 degF. Export:
unset.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degF
Tmodule:
name: Tmodule
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tmodule[degF]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degF
Tambient:
name: Tambient
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tambient[degC]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degC
wind_speed:
name: wind_speed
annotations:
order:
tag: order
value: 23
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: wind_speed[mph]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
- windturb_dg
range: float
required: false
unit:
ucum_code: mph
ambient_temperature:
name: ambient_temperature
annotations:
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: ambient_temperature[degF]
description: Current ambient temperature of air
from_schema: https://gridlabd.org/schema/glm/generators/solar
owner: solar
domain_of:
- transformer
- solar
range: float
required: false
unit:
ucum_code: degF
Insolation:
name: Insolation
annotations:
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Insolation[W/sf]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: W/sf
Rinternal:
name: Rinternal
annotations:
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rinternal[Ohm]
from_schema: https://gridlabd.org/schema/glm/generators/solar
owner: solar
domain_of:
- battery
- solar
range: float
required: false
unit:
ucum_code: Ohm
Rated_Insolation:
name: Rated_Insolation
annotations:
order:
tag: order
value: 27
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Rated_Insolation[W/sf]
comments:
- 'Import: SolarPanelInfo.referenceIrradiation (W/m^2, from W/ft^2); irradiance
= Rated_Insolation x shading_factor; default 92.902 W/sf (1000 W/m^2). Export:
referenceIrradiation.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:SolarPanelInfo.referenceIrradiation
- cim:PhotoVoltaicUnit.irradiance
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: W/sf
Pmax_temp_coeff:
name: Pmax_temp_coeff
annotations:
order:
tag: order
value: 28
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pmax_temp_coeff
comments:
- 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
(W, load sign); per degF, default by panel_type. Export: unset.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
Voc_temp_coeff:
name: Voc_temp_coeff
annotations:
order:
tag: order
value: 29
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Voc_temp_coeff
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
V_Max:
name: V_Max
annotations:
order:
tag: order
value: 30
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_Max[V]
from_schema: https://gridlabd.org/schema/glm/generators/solar
owner: solar
domain_of:
- battery
- solar
range: float
required: false
unit:
ucum_code: V
Voc_Max:
name: Voc_Max
annotations:
order:
tag: order
value: 31
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Voc_Max[V]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: V
Voc:
name: Voc
annotations:
order:
tag: order
value: 32
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Voc[V]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: V
efficiency:
name: efficiency
annotations:
order:
tag: order
value: 33
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: efficiency[unit]
comments:
- 'Import: SolarPanelInfo.efficiency (percent); default by panel_type. Export:
efficiency as a fraction.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:SolarPanelInfo.efficiency
owner: solar
domain_of:
- vfd
- battery
- diesel_dg
- solar
range: float
required: false
unit:
ucum_code: unit
area:
name: area
annotations:
order:
tag: order
value: 34
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: area[sf]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: sf
soiling:
name: soiling
annotations:
order:
tag: order
value: 35
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: soiling[pu]
description: Soiling of array factor - representing dirt on array
comments:
- 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
(W, load sign); default 0.95; outside 0..1 raises. Export: 1.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: pu
derating:
name: derating
annotations:
order:
tag: order
value: 36
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: derating[pu]
description: Panel derating to account for manufacturing variances
comments:
- 'Import: a factor of GridLAB-D''s static-weather DC output, which becomes PowerElectronicsConnection.p
(W, load sign); default 0.95; outside 0..1 raises. Export: p over GridLAB-D''s
lossless output, the whole loss.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: pu
Tcell:
name: Tcell
annotations:
order:
tag: order
value: 37
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tcell[degC]
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: degC
rated_power:
name: rated_power
annotations:
order:
tag: order
value: 38
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: rated_power[W]
description: Used to define the size of the solar panel in power rather than square
footage.
comments:
- 'Import: PhotoVoltaicUnit.maxP (W), minP 0, and the DC output; unset raises.
Export: maxP.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:PowerElectronicsUnit.maxP
owner: solar
domain_of:
- battery
- inverter
- inverter_dyn
- solar
range: float
required: false
unit:
ucum_code: W
P_Out:
name: P_Out
annotations:
order:
tag: order
value: 39
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: P_Out[kW]
from_schema: https://gridlabd.org/schema/glm/generators/solar
owner: solar
domain_of:
- inverter
- solar
range: float
required: false
unit:
ucum_code: kW
V_Out:
name: V_Out
annotations:
order:
tag: order
value: 40
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_Out[V]
from_schema: https://gridlabd.org/schema/glm/generators/solar
owner: solar
domain_of:
- battery
- rectifier
- solar
range: float
required: false
unit:
ucum_code: V
I_Out:
name: I_Out
annotations:
order:
tag: order
value: 41
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: I_Out[A]
from_schema: https://gridlabd.org/schema/glm/generators/solar
owner: solar
domain_of:
- battery
- rectifier
- solar
range: float
required: false
unit:
ucum_code: A
weather:
name: weather
annotations:
order:
tag: order
value: 42
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: weather
from_schema: https://gridlabd.org/schema/glm/generators/solar
owner: solar
domain_of:
- pqload
- solar
- house
range: string
required: false
shading_factor:
name: shading_factor
annotations:
order:
tag: order
value: 43
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: shading_factor[pu]
description: Shading factor for scaling solar power to the array
comments:
- 'Import: SolarArrayInfo.shadingFactor (percent) and a factor of the irradiance;
default 1. Export: shadingFactor as a fraction.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
close_mappings:
- cim:SolarArrayInfo.shadingFactor
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: pu
tilt_angle:
name: tilt_angle
annotations:
order:
tag: order
value: 44
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: tilt_angle[deg]
description: Tilt angle of PV array
comments:
- 'Import: SolarArrayInfo.tiltAngle (deg); default 45. Export: tiltAngle.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
exact_mappings:
- cim:SolarArrayInfo.tiltAngle
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: deg
orientation_azimuth:
name: orientation_azimuth
annotations:
order:
tag: order
value: 45
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: orientation_azimuth[deg]
description: Facing direction of the PV array
comments:
- 'Import: SolarArrayInfo.orientationAzimuth (deg); default 180. Export: orientationAzimuth.'
from_schema: https://gridlabd.org/schema/glm/generators/solar
exact_mappings:
- cim:SolarArrayInfo.orientationAzimuth
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
unit:
ucum_code: deg
latitude_angle_fix:
name: latitude_angle_fix
annotations:
order:
tag: order
value: 46
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: latitude_angle_fix
description: Fix tilt angle to installation latitude value
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: boolean
required: false
default_voltage_variable:
name: default_voltage_variable
annotations:
order:
tag: order
value: 47
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: default_voltage_variable
description: Accumulator/placeholder for default voltage value, when solar is
run without an inverter
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
default_current_variable:
name: default_current_variable
annotations:
order:
tag: order
value: 48
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: default_current_variable
description: Accumulator/placeholder for default current value, when solar is
run without an inverter
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
default_power_variable:
name: default_power_variable
annotations:
order:
tag: order
value: 49
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: default_power_variable
description: Accumulator/placeholder for default power value, when solar is run
without an inverter
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
prevTemp:
name: prevTemp
annotations:
order:
tag: order
value: 50
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: prevTemp
description: 'CHECKPOINT_VAR: internal variable for prevTemp'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
currTemp:
name: currTemp
annotations:
order:
tag: order
value: 51
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: currTemp
description: 'CHECKPOINT_VAR: internal variable for currTemp'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
prevTime:
name: prevTime
annotations:
order:
tag: order
value: 52
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: prevTime
description: 'CHECKPOINT_VAR: internal variable for prevTime'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: string
required: false
last_DC_current:
name: last_DC_current
annotations:
order:
tag: order
value: 53
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: last_DC_current
description: 'CHECKPOINT_VAR: internal variable for last_DC_current'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
last_DC_power:
name: last_DC_power
annotations:
order:
tag: order
value: 54
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: last_DC_power
description: 'CHECKPOINT_VAR: internal variable for last_DC_power'
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: float
required: false
orientation:
name: orientation
annotations:
order:
tag: order
value: 55
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: orientation
from_schema: https://gridlabd.org/schema/glm/generators/solar
rank: 1000
owner: solar
domain_of:
- solar
range: string
required: false
name:
name: name
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: name
description: The object's name; unique across the model.
comments:
- 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
(none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
share raises.'
from_schema: https://gridlabd.org/schema/glm/types/common
exact_mappings:
- cim:IdentifiedObject.name
rank: 1000
identifier: true
owner: solar
domain_of:
- glm_object
range: string
required: true
parent:
name: parent
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: parent
description: The parent object's name. A child node is solved as its parent's
bus; a nested object block sets it to the enclosing object.
comments:
- 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
on the root''s row; no object of its own. On a link it is not mapped.'
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: solar
domain_of:
- glm_object
range: string
groupid:
name: groupid
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: groupid
description: Free-text group label.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: solar
domain_of:
- glm_object
range: string
latitude:
name: latitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: latitude
description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: solar
domain_of:
- glm_object
range: string
longitude:
name: longitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: longitude
description: Longitude, as written.
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: solar
domain_of:
- glm_object
range: string
in_svc:
name: in_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: in_svc
description: Timestamp the object enters service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: solar
domain_of:
- glm_object
range: string
out_svc:
name: out_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: out_svc
description: Timestamp the object leaves service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: solar
domain_of:
- glm_object
range: string
rank:
name: rank
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: rank
description: Solver rank.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: solar
domain_of:
- glm_object
range: string
flags:
name: flags
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: flags
description: Core object flags.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: solar
domain_of:
- glm_object
range: string