Skip to content

Class: Inverter

Copyright (C) 2008 Battelle Memorial Institute

@file inverter.cpp

@defgroup inverter

@ingroup generators

@{

__

Inherits from: gld_object

__

Type: Instance (network topology element)

__

Note: Inherits from gld_object (not in generators module)

URI: glm:Inverter

 classDiagram
    class Inverter
    click Inverter href "../Inverter/"
      GlmObject <|-- Inverter
        click GlmObject href "../GlmObject/"

      Inverter : allowed_vv_action

      Inverter : b12

      Inverter : b23

      Inverter : b34

      Inverter : battery_soc

      Inverter : c_0

      Inverter : c_1

      Inverter : c_2

      Inverter : c_3

      Inverter : charge_lockout_time

      Inverter : charge_off_threshold

      Inverter : charge_on_threshold

      Inverter : charge_threshold

      Inverter : curr_VA_out_A





        Inverter --> "0..1" Complex : curr_VA_out_A
        click Complex href "../Complex/"



      Inverter : curr_VA_out_B





        Inverter --> "0..1" Complex : curr_VA_out_B
        click Complex href "../Complex/"



      Inverter : curr_VA_out_C





        Inverter --> "0..1" Complex : curr_VA_out_C
        click Complex href "../Complex/"



      Inverter : current_convergence

      Inverter : delay_time

      Inverter : delta_epA

      Inverter : delta_epB

      Inverter : delta_epC

      Inverter : delta_eqA

      Inverter : delta_eqB

      Inverter : delta_eqC

      Inverter : delta_mdA

      Inverter : delta_mdB

      Inverter : delta_mdC

      Inverter : delta_mqA

      Inverter : delta_mqB

      Inverter : delta_mqC

      Inverter : deltamode_inclusive

      Inverter : disable_volt_var_if_no_input_power

      Inverter : discharge_lockout_time

      Inverter : discharge_off_threshold

      Inverter : discharge_on_threshold

      Inverter : discharge_threshold

      Inverter : dynamic_model_mode

      Inverter : e_source_A

      Inverter : e_source_B

      Inverter : e_source_C

      Inverter : efficiency_value

      Inverter : enable_1547_checks

      Inverter : enable_ramp_rates_reactive

      Inverter : enable_ramp_rates_real

      Inverter : epA

      Inverter : epB

      Inverter : epC

      Inverter : eqA

      Inverter : eqB

      Inverter : eqC

      Inverter : event_deltat

      Inverter : excess_input_power

      Inverter : first_iter_counter

      Inverter : first_iteration_current_injection

      Inverter : first_run

      Inverter : first_sync_delta_enabled

      Inverter : flags

      Inverter : four_quadrant_control_mode

      Inverter : freq_pwr_sched

      Inverter : generator_mode





        Inverter --> "0..1" GeneratorMode : generator_mode
        click GeneratorMode href "../GeneratorMode/"



      Inverter : generator_status

      Inverter : group_max_charge_rate

      Inverter : group_max_discharge_rate

      Inverter : group_rated_power

      Inverter : groupid

      Inverter : I_In

      Inverter : IdqA





        Inverter --> "0..1" Complex : IdqA
        click Complex href "../Complex/"



      Inverter : IdqB





        Inverter --> "0..1" Complex : IdqB
        click Complex href "../Complex/"



      Inverter : IdqC





        Inverter --> "0..1" Complex : IdqC
        click Complex href "../Complex/"



      Inverter : IEEE_1547_STATUS

      Inverter : IEEE_1547_trip_method





        Inverter --> "0..1" Ieee1547TripMethod : IEEE_1547_trip_method
        click Ieee1547TripMethod href "../Ieee1547TripMethod/"



      Inverter : IEEE_1547_version





        Inverter --> "0..1" Ieee1547Version : IEEE_1547_version
        click Ieee1547Version href "../Ieee1547Version/"



      Inverter : in_svc

      Inverter : inverter_1547_status

      Inverter : inverter_convergence_criterion

      Inverter : inverter_droop_fp

      Inverter : inverter_droop_vq

      Inverter : inverter_efficiency

      Inverter : inverter_first_step

      Inverter : inverter_manufacturer

      Inverter : inverter_type

      Inverter : islanded_state

      Inverter : kdd

      Inverter : kdq

      Inverter : ki_Vterminal

      Inverter : kid

      Inverter : kipmax

      Inverter : kiq

      Inverter : kp_Vterminal

      Inverter : kpd

      Inverter : kppmax

      Inverter : kpq

      Inverter : last_current_A





        Inverter --> "0..1" Complex : last_current_A
        click Complex href "../Complex/"



      Inverter : last_current_B





        Inverter --> "0..1" Complex : last_current_B
        click Complex href "../Complex/"



      Inverter : last_current_C





        Inverter --> "0..1" Complex : last_current_C
        click Complex href "../Complex/"



      Inverter : last_current_D





        Inverter --> "0..1" Complex : last_current_D
        click Complex href "../Complex/"



      Inverter : last_I_In

      Inverter : last_I_Out_A





        Inverter --> "0..1" Complex : last_I_Out_A
        click Complex href "../Complex/"



      Inverter : last_I_Out_B





        Inverter --> "0..1" Complex : last_I_Out_B
        click Complex href "../Complex/"



      Inverter : last_I_Out_C





        Inverter --> "0..1" Complex : last_I_Out_C
        click Complex href "../Complex/"



      Inverter : last_power_A





        Inverter --> "0..1" Complex : last_power_A
        click Complex href "../Complex/"



      Inverter : last_power_B





        Inverter --> "0..1" Complex : last_power_B
        click Complex href "../Complex/"



      Inverter : last_power_C





        Inverter --> "0..1" Complex : last_power_C
        click Complex href "../Complex/"



      Inverter : last_power_D





        Inverter --> "0..1" Complex : last_power_D
        click Complex href "../Complex/"



      Inverter : last_vv_check

      Inverter : latitude

      Inverter : lf_dispatch_change_allowed

      Inverter : lf_dispatch_power

      Inverter : load_follow_status

      Inverter : longitude

      Inverter : m12

      Inverter : m23

      Inverter : m34

      Inverter : max_charge_rate

      Inverter : max_discharge_rate

      Inverter : max_pwr_slew_rate

      Inverter : max_ramp_down_reactive

      Inverter : max_ramp_down_real

      Inverter : max_ramp_up_reactive

      Inverter : max_ramp_up_real

      Inverter : max_var_slew_rate

      Inverter : maximum_dc_power

      Inverter : maximum_dc_voltage

      Inverter : mdA

      Inverter : mdB

      Inverter : mdC

      Inverter : minimum_dc_power

      Inverter : mqA

      Inverter : mqB

      Inverter : mqC

      Inverter : name

      Inverter : next_update_time

      Inverter : nominal_frequency

      Inverter : number_of_phases_out

      Inverter : out_of_violation_time_total

      Inverter : out_svc

      Inverter : over_freq_high_band_viol_time

      Inverter : over_freq_high_cutout

      Inverter : over_freq_high_disconnect_time

      Inverter : over_freq_low_band_viol_time

      Inverter : over_freq_low_cutout

      Inverter : over_freq_low_disconnect_time

      Inverter : over_voltage_high_cutout

      Inverter : over_voltage_high_disconnect_time

      Inverter : over_voltage_high_viol_time

      Inverter : over_voltage_low_cutout

      Inverter : over_voltage_low_disconnect_time

      Inverter : over_voltage_low_viol_time

      Inverter : P_In

      Inverter : P_Out

      Inverter : pa_vw_limited

      Inverter : parent

      Inverter : pb_vw_limited

      Inverter : pc_vw_limited

      Inverter : pCircuit_V_Avg

      Inverter : pf_reg

      Inverter : pf_reg_activate

      Inverter : pf_reg_activate_lockout_time

      Inverter : pf_reg_deactivate

      Inverter : pf_reg_dispatch_change_allowed

      Inverter : pf_reg_dispatch_VAR

      Inverter : pf_reg_high

      Inverter : pf_reg_low

      Inverter : pf_reg_next_update_time

      Inverter : pf_reg_status

      Inverter : pf_target

      Inverter : phaseA_I_Following





        Inverter --> "0..1" Complex : phaseA_I_Following
        click Complex href "../Complex/"



      Inverter : phaseA_I_Forming





        Inverter --> "0..1" Complex : phaseA_I_Forming
        click Complex href "../Complex/"



      Inverter : phaseA_I_Out





        Inverter --> "0..1" Complex : phaseA_I_Out
        click Complex href "../Complex/"



      Inverter : phaseA_V_Out





        Inverter --> "0..1" Complex : phaseA_V_Out
        click Complex href "../Complex/"



      Inverter : phaseB_I_Following





        Inverter --> "0..1" Complex : phaseB_I_Following
        click Complex href "../Complex/"



      Inverter : phaseB_I_Forming





        Inverter --> "0..1" Complex : phaseB_I_Forming
        click Complex href "../Complex/"



      Inverter : phaseB_I_Out





        Inverter --> "0..1" Complex : phaseB_I_Out
        click Complex href "../Complex/"



      Inverter : phaseB_V_Out





        Inverter --> "0..1" Complex : phaseB_V_Out
        click Complex href "../Complex/"



      Inverter : phaseC_I_Following





        Inverter --> "0..1" Complex : phaseC_I_Following
        click Complex href "../Complex/"



      Inverter : phaseC_I_Forming





        Inverter --> "0..1" Complex : phaseC_I_Forming
        click Complex href "../Complex/"



      Inverter : phaseC_I_Out





        Inverter --> "0..1" Complex : phaseC_I_Out
        click Complex href "../Complex/"



      Inverter : phaseC_V_Out





        Inverter --> "0..1" Complex : phaseC_V_Out
        click Complex href "../Complex/"



      Inverter : phases

      Inverter : Pmax

      Inverter : Pmax_Low_Limit

      Inverter : Pmin

      Inverter : power_A





        Inverter --> "0..1" Complex : power_A
        click Complex href "../Complex/"



      Inverter : power_B





        Inverter --> "0..1" Complex : power_B
        click Complex href "../Complex/"



      Inverter : power_C





        Inverter --> "0..1" Complex : power_C
        click Complex href "../Complex/"



      Inverter : power_factor

      Inverter : power_in

      Inverter : Pref

      Inverter : prev_time

      Inverter : prev_time_dbl

      Inverter : prev_VA_out_A





        Inverter --> "0..1" Complex : prev_VA_out_A
        click Complex href "../Complex/"



      Inverter : prev_VA_out_B





        Inverter --> "0..1" Complex : prev_VA_out_B
        click Complex href "../Complex/"



      Inverter : prev_VA_out_C





        Inverter --> "0..1" Complex : prev_VA_out_C
        click Complex href "../Complex/"



      Inverter : prev_value_IGenerated_A





        Inverter --> "0..1" Complex : prev_value_IGenerated_A
        click Complex href "../Complex/"



      Inverter : prev_value_IGenerated_B





        Inverter --> "0..1" Complex : prev_value_IGenerated_B
        click Complex href "../Complex/"



      Inverter : prev_value_IGenerated_C





        Inverter --> "0..1" Complex : prev_value_IGenerated_C
        click Complex href "../Complex/"



      Inverter : Q1

      Inverter : Q2

      Inverter : Q3

      Inverter : Q4

      Inverter : Q_Out

      Inverter : Qref

      Inverter : R_fp

      Inverter : R_vq

      Inverter : rank

      Inverter : rated_battery_power

      Inverter : rated_power

      Inverter : reconnect_time

      Inverter : sense_object

      Inverter : soc_reserve

      Inverter : start_time

      Inverter : Tfreq_delay

      Inverter : Tp_delay

      Inverter : Tq_delay

      Inverter : Tvol_delay

      Inverter : under_freq_high_cutout

      Inverter : under_freq_high_disconnect_time

      Inverter : under_freq_low_band_viol_time

      Inverter : under_freq_low_cutout

      Inverter : under_freq_low_disconnect_time

      Inverter : under_voltage_high_cutout

      Inverter : under_voltage_high_disconnect_time

      Inverter : under_voltage_high_viol_time

      Inverter : under_voltage_low_cutout

      Inverter : under_voltage_low_disconnect_time

      Inverter : under_voltage_lowest_viol_time

      Inverter : under_voltage_middle_cutout

      Inverter : under_voltage_middle_disconnect_time

      Inverter : under_voltage_middle_viol_time

      Inverter : use_multipoint_efficiency

      Inverter : V1

      Inverter : V2

      Inverter : V3

      Inverter : V4

      Inverter : V_angle_A

      Inverter : V_angle_B

      Inverter : V_angle_C

      Inverter : V_base

      Inverter : V_In

      Inverter : V_set0

      Inverter : V_set1

      Inverter : V_set2

      Inverter : V_set_droop

      Inverter : VA_Out





        Inverter --> "0..1" Complex : VA_Out
        click Complex href "../Complex/"



      Inverter : Vdc

      Inverter : volt_var_control_lockout

      Inverter : volt_var_sched

      Inverter : VSI_freq

      Inverter : VSI_mode

      Inverter : VSI_Rfilter





        Inverter --> "0..1" Complex : VSI_Rfilter
        click Complex href "../Complex/"



      Inverter : VSI_Xfilter





        Inverter --> "0..1" Complex : VSI_Xfilter
        click Complex href "../Complex/"



      Inverter : VW_P1

      Inverter : VW_P2

      Inverter : VW_V1

      Inverter : VW_V2

      Inverter : WT_is_connected

Inheritance

Slots

Name Cardinality and Range Description Inheritance
inverter_type 0..1
String
LEGACY MODEL: Sets efficiencies and other parameters; if using four_quadrant_... direct
four_quadrant_control_mode 0..1
String
FOUR QUADRANT MODEL: Activates various control modes direct
pf_reg 0..1
String
Activate (or not) power factor regulation in four_quadrant_control_mode direct
generator_status 0..1
String
describes whether the generator is online or offline direct
generator_mode 0..1
GeneratorMode
LEGACY MODEL: Selects generator control mode when using legacy model; in non-... direct
inverter_convergence_criterion 0..1
Float
The maximum change in error threshold for exitting deltamode direct
current_convergence 0..1
Float
Convergence criterion for current changes on first timestep - basically initi... direct
V_In 0..1
Float
DC voltage direct
I_In 0..1
Float
DC current direct
P_In 0..1
Float
DC power direct
VA_Out 0..1
Complex
AC power direct
Vdc 0..1
Float
LEGACY MODEL: DC voltage direct
phaseA_V_Out 0..1
Complex
AC voltage on A phase in three-phase system; 240-V connection on a triplex sy... direct
phaseB_V_Out 0..1
Complex
AC voltage on B phase in three-phase system direct
phaseC_V_Out 0..1
Complex
AC voltage on C phase in three-phase system direct
phaseA_I_Out 0..1
Complex
AC current on A phase in three-phase system; 240-V connection on a triplex sy... direct
phaseB_I_Out 0..1
Complex
AC current on B phase in three-phase system direct
phaseC_I_Out 0..1
Complex
AC current on C phase in three-phase system direct
power_A 0..1
Complex
AC power on A phase in three-phase system; 240-V connection on a triplex syst... direct
power_B 0..1
Complex
AC power on B phase in three-phase system direct
power_C 0..1
Complex
AC power on C phase in three-phase system direct
curr_VA_out_A 0..1
Complex
AC power on A phase in three-phase system; 240-V connection on a triplex syst... direct
curr_VA_out_B 0..1
Complex
AC power on B phase in three-phase system direct
curr_VA_out_C 0..1
Complex
AC power on C phase in three-phase system direct
prev_VA_out_A 0..1
Complex
AC power on A phase in three-phase system; 240-V connection on a triplex syst... direct
prev_VA_out_B 0..1
Complex
AC power on B phase in three-phase system direct
prev_VA_out_C 0..1
Complex
AC power on C phase in three-phase system direct
e_source_A 0..1
Float
DELTAMODE: Internal voltage of grid-forming source, phase A direct
e_source_B 0..1
Float
DELTAMODE: Internal voltage of grid-forming source, phase B direct
e_source_C 0..1
Float
DELTAMODE: Internal voltage of grid-forming source, phase C direct
V_angle_A 0..1
Float
DELTAMODE: Internal angle of grid-forming source, phase A direct
V_angle_B 0..1
Float
DELTAMODE: Internal angle of grid-forming source, phase B direct
V_angle_C 0..1
Float
DELTAMODE: Internal angle of grid-forming source, phase C direct
phaseA_I_Forming 0..1
Complex
AC current on A phase in three-phase system, only for grid_forming direct
phaseB_I_Forming 0..1
Complex
AC current on B phase in three-phase system, only for grid_forming direct
phaseC_I_Forming 0..1
Complex
AC current on C phase in three-phase system, only for grid_forming direct
phaseA_I_Following 0..1
Complex
AC current on A phase in three-phase system, only for grid_following direct
phaseB_I_Following 0..1
Complex
AC current on B phase in three-phase system, only for grid_following direct
phaseC_I_Following 0..1
Complex
AC current on C phase in three-phase system, only for grid_following direct
pCircuit_V_Avg 0..1
Float
DELTAMODE: three-phase average value of terminal voltage direct
P_Out 0..1
Float
FOUR QUADRANT MODEL: Scheduled real power out in CONSTANT_PQ control mode direct
Q_Out 0..1
Float
FOUR QUADRANT MODEL: Schedule reactive power out in CONSTANT_PQ control mode direct
power_in 0..1
Float
LEGACY MODEL: No longer used direct
rated_power 0..1
Float
FOUR QUADRANT MODEL: The rated power of the inverter direct
rated_battery_power 0..1
Float
FOUR QUADRANT MODEL: The rated power of battery when battery is attached direct
inverter_efficiency 0..1
Float
FOUR QUADRANT MODEL: The efficiency of the inverter direct
battery_soc 0..1
Float
FOUR QUADRANT MODEL: The state of charge of an attached battery direct
soc_reserve 0..1
Float
FOUR QUADRANT MODEL: The reserve state of charge of an attached battery for i... direct
power_factor 0..1
Float
FOUR QUADRANT MODEL: The power factor used for CONSTANT_PF control mode direct
islanded_state 0..1
Boolean
FOUR QUADRANT MODEL: Boolean used to let control modes to act under island co... direct
nominal_frequency 0..1
Float
direct
Pref 0..1
Float
DELTAMODE: The real power reference direct
Qref 0..1
Float
DELTAMODE: The reactive power reference direct
kpd 0..1
Float
DELTAMODE: The d-axis integration gain for the current modulation PI controll... direct
kpq 0..1
Float
DELTAMODE: The q-axis integration gain for the current modulation PI controll... direct
kid 0..1
Float
DELTAMODE: The d-axis proportional gain for the current modulation PI control... direct
kiq 0..1
Float
DELTAMODE: The q-axis proportional gain for the current modulation PI control... direct
kdd 0..1
Float
DELTAMODE: The d-axis differentiator gain for the current modulation PID cont... direct
kdq 0..1
Float
DELTAMODE: The q-axis differentiator gain for the current modulation PID cont... direct
epA 0..1
Float
DELTAMODE: The real current error for phase A or triplex phase direct
epB 0..1
Float
DELTAMODE: The real current error for phase B direct
epC 0..1
Float
DELTAMODE: The real current error for phase C direct
eqA 0..1
Float
DELTAMODE: The reactive current error for phase A or triplex phase direct
eqB 0..1
Float
DELTAMODE: The reactive current error for phase B direct
eqC 0..1
Float
DELTAMODE: The reactive current error for phase C direct
delta_epA 0..1
Float
DELTAMODE: The change in real current error for phase A or triplex phase direct
delta_epB 0..1
Float
DELTAMODE: The change in real current error for phase B direct
delta_epC 0..1
Float
DELTAMODE: The change in real current error for phase C direct
delta_eqA 0..1
Float
DELTAMODE: The change in reactive current error for phase A or triplex phase direct
delta_eqB 0..1
Float
DELTAMODE: The change in reactive current error for phase B direct
delta_eqC 0..1
Float
DELTAMODE: The change in reactive current error for phase C direct
mdA 0..1
Float
DELTAMODE: The d-axis current modulation for phase A or triplex phase direct
mdB 0..1
Float
DELTAMODE: The d-axis current modulation for phase B direct
mdC 0..1
Float
DELTAMODE: The d-axis current modulation for phase C direct
mqA 0..1
Float
DELTAMODE: The q-axis current modulation for phase A or triplex phase direct
mqB 0..1
Float
DELTAMODE: The q-axis current modulation for phase B direct
mqC 0..1
Float
DELTAMODE: The q-axis current modulation for phase C direct
delta_mdA 0..1
Float
DELTAMODE: The change in d-axis current modulation for phase A or triplex pha... direct
delta_mdB 0..1
Float
DELTAMODE: The change in d-axis current modulation for phase B direct
delta_mdC 0..1
Float
DELTAMODE: The change in d-axis current modulation for phase C direct
delta_mqA 0..1
Float
DELTAMODE: The change in q-axis current modulation for phase A or triplex pha... direct
delta_mqB 0..1
Float
DELTAMODE: The change in q-axis current modulation for phase B direct
delta_mqC 0..1
Float
DELTAMODE: The change in q-axis current modulation for phase C direct
IdqA 0..1
Complex
DELTAMODE: The dq-axis current for phase A or triplex phase direct
IdqB 0..1
Complex
DELTAMODE: The dq-axis current for phase B direct
IdqC 0..1
Complex
DELTAMODE: The dq-axis current for phase C direct
Tfreq_delay 0..1
Float
DELTAMODE: The time constant for delayed frequency seen by the inverter direct
inverter_droop_fp 0..1
Boolean
DELTAMODE: Boolean used to indicate whether inverter f/p droop is included or... direct
R_fp 0..1
Float
DELTAMODE: The droop parameter of the f/p droop direct
kppmax 0..1
Float
DELTAMODE: The proportional gain of Pmax controller direct
kipmax 0..1
Float
DELTAMODE: The integral gain of Pmax controller direct
Pmax 0..1
Float
DELTAMODE: power limit of grid forming inverter direct
Pmin 0..1
Float
DELTAMODE: power limit of grid forming inverter direct
Pmax_Low_Limit 0..1
Float
DELTAMODE: output limit of Pmax controller direct
Tvol_delay 0..1
Float
DELTAMODE: The time constant for delayed voltage seen by the inverter direct
inverter_droop_vq 0..1
Boolean
DELTAMODE: Boolean used to indicate whether inverter q/v droop is included or... direct
R_vq 0..1
Float
DELTAMODE: The droop parameter of the v/q droop direct
Tp_delay 0..1
Float
DELTAMODE: The time constant for delayed real power seen by the VSI droop con... direct
Tq_delay 0..1
Float
DELTAMODE: The time constant for delayed reactive power seen by the VSI droop... direct
VSI_Rfilter 0..1
Complex
VSI filter resistance (p direct
VSI_Xfilter 0..1
Complex
VSI filter inductance (p direct
VSI_mode 0..1
String
VSI MODEL: Selects VSI mode for either isochronous or droop one direct
VSI_freq 0..1
Float
VSI frequency direct
ki_Vterminal 0..1
Float
DELTAMODE: The integrator gain for the VSI terminal voltage modulation direct
kp_Vterminal 0..1
Float
DELTAMODE: The proportional gain for the VSI terminal voltage modulation direct
V_set_droop 0..1
Float
DELTAMODE: The voltage setpoint of droop control direct
V_set0 0..1
Float
DELTAMODE: The voltage setpoint of grid-following Q-V droop control direct
V_set1 0..1
Float
DELTAMODE: The voltage setpoint of grid-following Q-V droop control direct
V_set2 0..1
Float
DELTAMODE: The voltage setpoint of grid-following Q-V droop control direct
enable_ramp_rates_real 0..1
Boolean
DELTAMODE: Boolean used to indicate whether inverter ramp rate is enforced or... direct
max_ramp_up_real 0..1
Float
DELTAMODE: The real power ramp up rate limit direct
max_ramp_down_real 0..1
Float
DELTAMODE: The real power ramp down rate limit direct
enable_ramp_rates_reactive 0..1
Boolean
DELTAMODE: Boolean used to indicate whether inverter ramp rate is enforced or... direct
max_ramp_up_reactive 0..1
Float
DELTAMODE: The reactive power ramp up rate limit direct
max_ramp_down_reactive 0..1
Float
DELTAMODE: The reactive power ramp down rate limit direct
dynamic_model_mode 0..1
String
DELTAMODE: Underlying model to use for deltamode control direct
enable_1547_checks 0..1
Boolean
DELTAMODE: Enable IEEE 1547-2003 disconnect checking direct
reconnect_time 0..1
Float
DELTAMODE: Time delay after IEEE 1547-2003 violation clears before resuming g... direct
inverter_1547_status 0..1
Boolean
DELTAMODE: Indicator if the inverter is curtailed due to a 1547 violation or ... direct
IEEE_1547_version 0..1
Ieee1547Version
DELTAMODE: Version of IEEE 1547 to use to populate defaults direct
over_freq_high_cutout 0..1
Float
DELTAMODE: OF2 set point for IEEE 1547a direct
over_freq_high_disconnect_time 0..1
Float
DELTAMODE: OF2 clearing time for IEEE1547a direct
over_freq_low_cutout 0..1
Float
DELTAMODE: OF1 set point for IEEE 1547a direct
over_freq_low_disconnect_time 0..1
Float
DELTAMODE: OF1 clearing time for IEEE 1547a direct
under_freq_high_cutout 0..1
Float
DELTAMODE: UF2 set point for IEEE 1547a direct
under_freq_high_disconnect_time 0..1
Float
DELTAMODE: UF2 clearing time for IEEE1547a direct
under_freq_low_cutout 0..1
Float
DELTAMODE: UF1 set point for IEEE 1547a direct
under_freq_low_disconnect_time 0..1
Float
DELTAMODE: UF1 clearing time for IEEE 1547a direct
under_voltage_low_cutout 0..1
Float
Lowest voltage threshold for undervoltage direct
under_voltage_middle_cutout 0..1
Float
Middle-lowest voltage threshold for undervoltage direct
under_voltage_high_cutout 0..1
Float
High value of low voltage threshold for undervoltage direct
over_voltage_low_cutout 0..1
Float
Lowest voltage value for overvoltage direct
over_voltage_high_cutout 0..1
Float
High voltage value for overvoltage direct
under_voltage_low_disconnect_time 0..1
Float
Lowest voltage clearing time for undervoltage direct
under_voltage_middle_disconnect_time 0..1
Float
Middle-lowest voltage clearing time for undervoltage direct
under_voltage_high_disconnect_time 0..1
Float
Highest voltage clearing time for undervoltage direct
over_voltage_low_disconnect_time 0..1
Float
Lowest voltage clearing time for overvoltage direct
over_voltage_high_disconnect_time 0..1
Float
Highest voltage clearing time for overvoltage direct
IEEE_1547_trip_method 0..1
Ieee1547TripMethod
High over-voltage level trip direct
phases 0..1
String
The phases the inverter is attached to direct
use_multipoint_efficiency 0..1
Boolean
FOUR QUADRANT MODEL: boolean to used the multipoint efficiency curve for the ... direct
inverter_manufacturer 0..1
String
MULTIPOINT EFFICIENCY MODEL: the manufacturer of the inverter to setup up pre... direct
maximum_dc_power 0..1
Float
MULTIPOINT EFFICIENCY MODEL: the maximum dc power point for the efficiency cu... direct
maximum_dc_voltage 0..1
Float
MULTIPOINT EFFICIENCY MODEL: the maximum dc voltage point for the efficiency ... direct
minimum_dc_power 0..1
Float
MULTIPOINT EFFICIENCY MODEL: the minimum dc power point for the efficiency cu... direct
c_0 0..1
Float
MULTIPOINT EFFICIENCY MODEL: the first coefficient in the efficiency curve direct
c_1 0..1
Float
MULTIPOINT EFFICIENCY MODEL: the second coefficient in the efficiency curve direct
c_2 0..1
Float
MULTIPOINT EFFICIENCY MODEL: the third coefficient in the efficiency curve direct
c_3 0..1
Float
MULTIPOINT EFFICIENCY MODEL: the fourth coefficient in the efficiency curve direct
sense_object 0..1
String
FOUR QUADRANT MODEL: name of the object the inverter is trying to mitigate th... direct
max_charge_rate 0..1
Float
FOUR QUADRANT MODEL: maximum rate the battery can be charged in LOAD_FOLLOWIN... direct
max_discharge_rate 0..1
Float
FOUR QUADRANT MODEL: maximum rate the battery can be discharged in LOAD_FOLLO... direct
charge_on_threshold 0..1
Float
FOUR QUADRANT MODEL: power level at which the inverter should try charging th... direct
charge_off_threshold 0..1
Float
FOUR QUADRANT MODEL: power level at which the inverter should cease charging ... direct
discharge_on_threshold 0..1
Float
FOUR QUADRANT MODEL: power level at which the inverter should try discharging... direct
discharge_off_threshold 0..1
Float
FOUR QUADRANT MODEL: power level at which the inverter should cease dischargi... direct
excess_input_power 0..1
Float
FOUR QUADRANT MODEL: Excess power at the input of the inverter that is otherw... direct
charge_lockout_time 0..1
Float
FOUR QUADRANT MODEL: Lockout time when a charging operation occurs before ano... direct
discharge_lockout_time 0..1
Float
FOUR QUADRANT MODEL: Lockout time when a discharging operation occurs before ... direct
pf_reg_activate 0..1
Float
FOUR QUADRANT MODEL: Lowest acceptable power-factor level below which power-f... direct
pf_reg_deactivate 0..1
Float
FOUR QUADRANT MODEL: Lowest acceptable power-factor above which no power-fact... direct
pf_target 0..1
Float
FOUR QUADRANT MODEL: Desired power-factor to maintain (signed) positive is in... direct
pf_reg_high 0..1
Float
FOUR QUADRANT MODEL: Upper limit for power-factor - if exceeds, go full rever... direct
pf_reg_low 0..1
Float
FOUR QUADRANT MODEL: Lower limit for power-factor - if exceeds, stop regulati... direct
pf_reg_activate_lockout_time 0..1
Float
FOUR QUADRANT MODEL: Mandatory pause between the deactivation of power-factor... direct
disable_volt_var_if_no_input_power 0..1
Boolean
direct
delay_time 0..1
Float
direct
max_var_slew_rate 0..1
Float
direct
max_pwr_slew_rate 0..1
Float
direct
volt_var_sched 0..1
String
direct
freq_pwr_sched 0..1
String
direct
charge_threshold 0..1
Float
FOUR QUADRANT MODEL: Level at which all inverters in the group will begin cha... direct
discharge_threshold 0..1
Float
FOUR QUADRANT MODEL: Level at which all inverters in the group will begin dis... direct
group_max_charge_rate 0..1
Float
FOUR QUADRANT MODEL: Sum of the charge rates of the batteries involved in the... direct
group_max_discharge_rate 0..1
Float
FOUR QUADRANT MODEL: Sum of the discharge rates of the batteries involved in ... direct
group_rated_power 0..1
Float
FOUR QUADRANT MODEL: Sum of the inverter power ratings of the inverters invol... direct
V_base 0..1
Float
FOUR QUADRANT MODEL: The base voltage on the grid side of the inverter direct
V1 0..1
Float
FOUR QUADRANT MODEL: voltage point 1 in volt/var curve direct
Q1 0..1
Float
FOUR QUADRANT MODEL: VAR point 1 in volt/var curve direct
V2 0..1
Float
FOUR QUADRANT MODEL: voltage point 2 in volt/var curve direct
Q2 0..1
Float
FOUR QUADRANT MODEL: VAR point 2 in volt/var curve direct
V3 0..1
Float
FOUR QUADRANT MODEL: voltage point 3 in volt/var curve direct
Q3 0..1
Float
FOUR QUADRANT MODEL: VAR point 3 in volt/var curve direct
V4 0..1
Float
FOUR QUADRANT MODEL: voltage point 4 in volt/var curve direct
Q4 0..1
Float
FOUR QUADRANT MODEL: VAR point 4 in volt/var curve direct
volt_var_control_lockout 0..1
Float
FOUR QUADRANT QUADRANT MODEL: the lockout time between volt/var actions direct
number_of_phases_out 0..1
Integer
Exposed variable - hidden for solar direct
efficiency_value 0..1
Float
Exposed variable - hidden for solar direct
VW_V1 0..1
Float
FOUR QUADRANT MODEL: Voltage at which power limiting begins (e direct
VW_V2 0..1
Float
FOUR QUADRANT MODEL: Voltage at which power limiting ends direct
VW_P1 0..1
Float
FOUR QUADRANT MODEL: Power limit at VW_P1 (e direct
VW_P2 0..1
Float
FOUR QUADRANT MODEL: Power limit at VW_P2 (e direct
WT_is_connected 0..1
Boolean
Internal flag that indicates a wind turbine child is connected direct
pf_reg_status 0..1
String
CHECKPOINT_VAR: internal variable for pf_reg_status direct
load_follow_status 0..1
String
CHECKPOINT_VAR: Status variable for what the load_following mode is doing direct
last_current_A 0..1
Complex
CHECKPOINT_VAR: Previously applied power output (used to remove from parent s... direct
last_current_B 0..1
Complex
CHECKPOINT_VAR: Previously applied power output (used to remove from parent s... direct
last_current_C 0..1
Complex
CHECKPOINT_VAR: Previously applied power output (used to remove from parent s... direct
last_current_D 0..1
Complex
CHECKPOINT_VAR: Previously applied power output (used to remove from parent s... direct
last_power_A 0..1
Complex
CHECKPOINT_VAR: Previously applied power output (as constant power) - used to... direct
last_power_B 0..1
Complex
CHECKPOINT_VAR: Previously applied power output (as constant power) - used to... direct
last_power_C 0..1
Complex
CHECKPOINT_VAR: Previously applied power output (as constant power) - used to... direct
last_power_D 0..1
Complex
CHECKPOINT_VAR: Previously applied power output (as constant power) - used to... direct
inverter_first_step 0..1
Boolean
CHECKPOINT_VAR: internal variable for inverter_first_step direct
first_iteration_current_injection 0..1
Integer
CHECKPOINT_VAR: Initialization variable - mostly so SWING_PQ buses initalize ... direct
m12 0..1
Float
CHECKPOINT_VAR: internal variable for m12 direct
b12 0..1
Float
CHECKPOINT_VAR: internal variable for b12 direct
m23 0..1
Float
CHECKPOINT_VAR: internal variable for m23 direct
b23 0..1
Float
CHECKPOINT_VAR: internal variable for b23 direct
m34 0..1
Float
CHECKPOINT_VAR: internal variable for m34 direct
b34 0..1
Float
CHECKPOINT_VAR: internal variable for b34 direct
allowed_vv_action 0..1
String
CHECKPOINT_VAR: internal variable for allowed_vv_action direct
last_vv_check 0..1
String
CHECKPOINT_VAR: internal variable for last_vv_check direct
IEEE_1547_STATUS 0..1
String
CHECKPOINT_VAR: internal variable for ieee_1547_version direct
over_freq_high_band_viol_time 0..1
Float
CHECKPOINT_VAR: OF2 violation accumulator direct
over_freq_low_band_viol_time 0..1
Float
CHECKPOINT_VAR: OF1 violation accumulator direct
under_freq_low_band_viol_time 0..1
Float
CHECKPOINT_VAR: UF1 violation accumulator direct
under_voltage_lowest_viol_time 0..1
Float
CHECKPOINT_VAR: Lowest low voltage threshold violation accumulator direct
under_voltage_middle_viol_time 0..1
Float
CHECKPOINT_VAR: Middle low voltage threshold violation accumulator direct
under_voltage_high_viol_time 0..1
Float
CHECKPOINT_VAR: Highest low voltage threshold violation accumulator direct
over_voltage_low_viol_time 0..1
Float
CHECKPOINT_VAR: Lowest high voltage threshold violation accumulator direct
over_voltage_high_viol_time 0..1
Float
CHECKPOINT_VAR: Highest high voltage threshold violation accumulator direct
lf_dispatch_power 0..1
Float
CHECKPOINT_VAR: Amount of real power to try and dispatch to meet thresholds direct
next_update_time 0..1
String
CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed direct
lf_dispatch_change_allowed 0..1
Boolean
CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed direct
pf_reg_dispatch_change_allowed 0..1
Boolean
CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed for power... direct
pf_reg_dispatch_VAR 0..1
Float
CHECKPOINT_VAR: (Reactive only?) power dispatched to meet power factor regula... direct
pf_reg_next_update_time 0..1
String
CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed direct
prev_time 0..1
String
CHECKPOINT_VAR: Tracking variable for previous "new time" run direct
prev_time_dbl 0..1
Float
CHECKPOINT_VAR: Tracking variable for 1547 checks and ramp rates direct
event_deltat 0..1
Float
CHECKPOINT_VAR: Event-driven delta-t variable direct
start_time 0..1
String
CHECKPOINT_VAR: Recording start time of simulation direct
last_I_Out_A 0..1
Complex
CHECKPOINT_VAR: internal variable for last_I_Out[0] direct
last_I_Out_B 0..1
Complex
CHECKPOINT_VAR: internal variable for last_I_Out[1] direct
last_I_Out_C 0..1
Complex
CHECKPOINT_VAR: internal variable for last_I_Out[2] direct
last_I_In 0..1
Float
CHECKPOINT_VAR: internal variable for last_I_In direct
pa_vw_limited 0..1
Float
CHECKPOINT_VAR: internal variable for pa_vw_limited direct
pb_vw_limited 0..1
Float
CHECKPOINT_VAR: internal variable for pb_vw_limited direct
pc_vw_limited 0..1
Float
CHECKPOINT_VAR: internal variable for pc_vw_limited direct
out_of_violation_time_total 0..1
Float
CHECKPOINT_VAR: internal variable for out_of_violation_time_total direct
deltamode_inclusive 0..1
Boolean
CHECKPOINT_VAR: Boolean for deltamode calls - pulled from object flags direct
first_sync_delta_enabled 0..1
Boolean
CHECKPOINT_VAR: internal variable for first_sync_delta_enabled direct
first_iter_counter 0..1
String
CHECKPOINT_VAR: internal variable for first_iter_counter direct
first_run 0..1
Boolean
CHECKPOINT_VAR: internal variable for first_run direct
prev_value_IGenerated_A 0..1
Complex
CHECKPOINT_VAR: internal variable for prev_value_IGenerated[0] direct
prev_value_IGenerated_B 0..1
Complex
CHECKPOINT_VAR: internal variable for prev_value_IGenerated[1] direct
prev_value_IGenerated_C 0..1
Complex
CHECKPOINT_VAR: internal variable for prev_value_IGenerated[2] direct
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: PowerElectronicsConnection, mRID pv_ or storage_ + name by its solar or battery child (inverter.cimtbl), with a GenerationInverterInfo or StorageInverterInfo datasheet; one child is mapped, GridLAB-D has no delta inverter. Export: each PowerElectronicsConnection, one inverter per unit (name_ when several), parented to its bus.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:Inverter
native glm:Inverter
exact cim:PowerElectronicsConnection
close cim:GenerationInverterInfo, cim:StorageInverterInfo

LinkML Source

Direct

name: inverter
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file inverter.cpp

  @defgroup inverter

  @ingroup generators

  @{


  Inherits from: gld_object


  Type: Instance (network topology element)


  Note: Inherits from gld_object (not in generators module)'
comments:
- 'Import: PowerElectronicsConnection, mRID pv_ or storage_ + name by its solar or
  battery child (inverter.cimtbl), with a GenerationInverterInfo or StorageInverterInfo
  datasheet; one child is mapped, GridLAB-D has no delta inverter. Export: each PowerElectronicsConnection,
  one inverter per unit (name_<n> when several), parented to its bus.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PowerElectronicsConnection
close_mappings:
- cim:GenerationInverterInfo
- cim:StorageInverterInfo
is_a: glm_object
attributes:
  inverter_type:
    name: inverter_type
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inverter_type
    description: 'LEGACY MODEL: Sets efficiencies and other parameters; if using four_quadrant_control_mode,
      set this to FOUR_QUADRANT'
    comments:
    - 'Import: structural; FOUR_QUADRANT only, any other raises (unset is GridLAB-D''s
      PWM). Export: FOUR_QUADRANT.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  four_quadrant_control_mode:
    name: four_quadrant_control_mode
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: four_quadrant_control_mode
    description: 'FOUR QUADRANT MODEL: Activates various control modes'
    comments:
    - 'Import: structural; CONSTANT_PF on a solar, CONSTANT_PQ on a battery (which
      also reads CONSTANT_PF), others raise; the mode''s capability flag goes in the
      row comment, InverterCapabilities is not written yet. Export: CONSTANT_PQ on
      a battery, CONSTANT_PF on a PV.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  pf_reg:
    name: pf_reg
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: pf_reg
    description: Activate (or not) power factor regulation in four_quadrant_control_mode
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  generator_status:
    name: generator_status
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: generator_status
    description: describes whether the generator is online or offline
    comments:
    - 'Import: ONLINE (default) is normallyInService true, OFFLINE false and the output
      0. Export: OFFLINE when normallyInService is false, else ONLINE.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:Equipment.normallyInService
    domain_of:
    - battery
    - inverter
    range: string
    required: false
  generator_mode:
    name: generator_mode
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: generator_mode
    description: 'LEGACY MODEL: Selects generator control mode when using legacy model;
      in non-legacy models, this should be SUPPLY_DRIVEN.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - battery
    - inverter
    - rectifier
    range: GeneratorMode
    required: false
  inverter_convergence_criterion:
    name: inverter_convergence_criterion
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: inverter_convergence_criterion
    description: The maximum change in error threshold for exitting deltamode.
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  current_convergence:
    name: current_convergence
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_convergence[A]
    description: Convergence criterion for current changes on first timestep - basically
      initialization of system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - diesel_dg
    - inverter
    range: float
    required: false
    unit:
      ucum_code: A
  V_In:
    name: V_In
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_In[V]
    description: DC voltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: V
  I_In:
    name: I_In
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: I_In[A]
    description: DC current
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - battery
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: A
  P_In:
    name: P_In
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: P_In[W]
    description: DC power
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: W
  VA_Out:
    name: VA_Out
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: VA_Out[VA]
    description: AC power
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - battery
    - inverter
    - inverter_dyn
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  Vdc:
    name: Vdc
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Vdc[V]
    description: 'LEGACY MODEL: DC voltage'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: V
  phaseA_V_Out:
    name: phaseA_V_Out
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseA_V_Out[V]
    description: AC voltage on A phase in three-phase system; 240-V connection on
      a triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseB_V_Out:
    name: phaseB_V_Out
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseB_V_Out[V]
    description: AC voltage on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseC_V_Out:
    name: phaseC_V_Out
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseC_V_Out[V]
    description: AC voltage on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseA_I_Out:
    name: phaseA_I_Out
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseA_I_Out[V]
    description: AC current on A phase in three-phase system; 240-V connection on
      a triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseB_I_Out:
    name: phaseB_I_Out
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseB_I_Out[V]
    description: AC current on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseC_I_Out:
    name: phaseC_I_Out
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseC_I_Out[V]
    description: AC current on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: Complex
    required: false
    unit:
      ucum_code: V
  power_A:
    name: power_A
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_A[VA]
    description: AC power on A phase in three-phase system; 240-V connection on a
      triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_B:
    name: power_B
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_B[VA]
    description: AC power on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_C:
    name: power_C
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_C[VA]
    description: AC power on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  curr_VA_out_A:
    name: curr_VA_out_A
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: curr_VA_out_A[VA]
    description: AC power on A phase in three-phase system; 240-V connection on a
      triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  curr_VA_out_B:
    name: curr_VA_out_B
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: curr_VA_out_B[VA]
    description: AC power on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  curr_VA_out_C:
    name: curr_VA_out_C
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: curr_VA_out_C[VA]
    description: AC power on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  prev_VA_out_A:
    name: prev_VA_out_A
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_VA_out_A[VA]
    description: AC power on A phase in three-phase system; 240-V connection on a
      triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  prev_VA_out_B:
    name: prev_VA_out_B
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_VA_out_B[VA]
    description: AC power on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  prev_VA_out_C:
    name: prev_VA_out_C
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_VA_out_C[VA]
    description: AC power on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  e_source_A:
    name: e_source_A
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: e_source_A
    description: 'DELTAMODE: Internal voltage of grid-forming source, phase A'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  e_source_B:
    name: e_source_B
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: e_source_B
    description: 'DELTAMODE: Internal voltage of grid-forming source, phase B'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  e_source_C:
    name: e_source_C
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: e_source_C
    description: 'DELTAMODE: Internal voltage of grid-forming source, phase C'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  V_angle_A:
    name: V_angle_A
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_angle_A
    description: 'DELTAMODE: Internal angle of grid-forming source, phase A'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  V_angle_B:
    name: V_angle_B
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_angle_B
    description: 'DELTAMODE: Internal angle of grid-forming source, phase B'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  V_angle_C:
    name: V_angle_C
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_angle_C
    description: 'DELTAMODE: Internal angle of grid-forming source, phase C'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  phaseA_I_Forming:
    name: phaseA_I_Forming
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseA_I_Forming[A]
    description: AC current on A phase in three-phase system, only for grid_forming
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseB_I_Forming:
    name: phaseB_I_Forming
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseB_I_Forming[A]
    description: AC current on B phase in three-phase system, only for grid_forming
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseC_I_Forming:
    name: phaseC_I_Forming
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseC_I_Forming[A]
    description: AC current on C phase in three-phase system, only for grid_forming
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseA_I_Following:
    name: phaseA_I_Following
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseA_I_Following[A]
    description: AC current on A phase in three-phase system, only for grid_following
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseB_I_Following:
    name: phaseB_I_Following
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseB_I_Following[A]
    description: AC current on B phase in three-phase system, only for grid_following
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseC_I_Following:
    name: phaseC_I_Following
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseC_I_Following[A]
    description: AC current on C phase in three-phase system, only for grid_following
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  pCircuit_V_Avg:
    name: pCircuit_V_Avg
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pCircuit_V_Avg
    description: 'DELTAMODE: three-phase average value of terminal voltage'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  P_Out:
    name: P_Out
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: P_Out[VA]
    description: 'FOUR QUADRANT MODEL: Scheduled real power out in CONSTANT_PQ control
      mode'
    comments:
    - 'Import: a battery''s CONSTANT_PQ set point, limited by ratedS, a full battery
      or the reserve, is p (W, load sign) and gives batteryState; a PV''s is an output
      GridLAB-D overwrites, so only in the row comment. Export: a battery''s p from
      get_inverter_units, generation sign.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.p
    - cim:BatteryUnit.batteryState
    rank: 1000
    domain_of:
    - inverter
    - solar
    range: float
    required: false
    unit:
      ucum_code: VA
  Q_Out:
    name: Q_Out
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q_Out[VAr]
    description: 'FOUR QUADRANT MODEL: Schedule reactive power out in CONSTANT_PQ
      control mode'
    comments:
    - 'Import: q (VAr) is 0 when unset or 0; any other value raises. Export: a battery''s
      q, generation sign.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.q
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: VAr
  power_in:
    name: power_in
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_in[W]
    description: 'LEGACY MODEL: No longer used'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - link
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  rated_power:
    name: rated_power
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: rated_power[VA]
    description: 'FOUR QUADRANT MODEL: The rated power of the inverter'
    comments:
    - 'Import: ratedS (VA) = rated_power x the phases out (3, 2, 1; S is 1); maxQ
      = -minQ = ratedS, and the datasheet''s apparentPowerMaximum; unset or 0 raises.
      Export: ratedS x the unit''s share / phases.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.ratedS
    - cim:PowerElectronicsConnection.maxQ
    - cim:PowerElectronicsConnection.minQ
    - cim:GridEdgeDeviceInfo.apparentPowerMaximum
    domain_of:
    - battery
    - inverter
    - inverter_dyn
    - solar
    range: float
    required: false
    unit:
      ucum_code: VA
  rated_battery_power:
    name: rated_battery_power
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: rated_battery_power[W]
    description: 'FOUR QUADRANT MODEL: The rated power of battery when battery is
      attached'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  inverter_efficiency:
    name: inverter_efficiency
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: inverter_efficiency
    description: 'FOUR QUADRANT MODEL: The efficiency of the inverter'
    comments:
    - 'Import: PV AC = DC x inverter_efficiency (default 0.9) is folded into p; CIM
      has no inverter efficiency. Export: 1 on a PV; the losses are in p.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  battery_soc:
    name: battery_soc
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: battery_soc[pu]
    description: 'FOUR QUADRANT MODEL: The state of charge of an attached battery'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  soc_reserve:
    name: soc_reserve
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: soc_reserve[pu]
    description: 'FOUR QUADRANT MODEL: The reserve state of charge of an attached
      battery for islanding cases'
    comments:
    - 'Import: BatteryUnit.minimumE (Wh) = soc_reserve x battery_capacity; default
      0. Export: minimumE / ratedE.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:BatteryUnit.minimumE
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  power_factor:
    name: power_factor
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_factor[unit]
    description: 'FOUR QUADRANT MODEL: The power factor used for CONSTANT_PF control
      mode'
    comments:
    - 'Import: CONSTANT_PF q is 0 when |pf| is 1; |pf| < 1 raises. Export: a PV''s
      p / |p + jq|, negative when q is.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.q
    domain_of:
    - performance_motor
    - battery
    - inverter
    - windturb_dg
    - residential_enduse
    range: float
    required: false
    unit:
      ucum_code: unit
  islanded_state:
    name: islanded_state
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: islanded_state
    description: 'FOUR QUADRANT MODEL: Boolean used to let control modes to act under
      island conditions'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  nominal_frequency:
    name: nominal_frequency
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_frequency[Hz]
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: Hz
  Pref:
    name: Pref
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pref
    description: 'DELTAMODE: The real power reference.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - diesel_dg
    - inverter
    - inverter_dyn
    range: float
    required: false
  Qref:
    name: Qref
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Qref
    description: 'DELTAMODE: The reactive power reference.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - diesel_dg
    - inverter
    - inverter_dyn
    range: float
    required: false
  kpd:
    name: kpd
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kpd
    description: 'DELTAMODE: The d-axis integration gain for the current modulation
      PI controller.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  kpq:
    name: kpq
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kpq
    description: 'DELTAMODE: The q-axis integration gain for the current modulation
      PI controller.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  kid:
    name: kid
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kid
    description: 'DELTAMODE: The d-axis proportional gain for the current modulation
      PI controller.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  kiq:
    name: kiq
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kiq
    description: 'DELTAMODE: The q-axis proportional gain for the current modulation
      PI controller.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  kdd:
    name: kdd
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kdd
    description: 'DELTAMODE: The d-axis differentiator gain for the current modulation
      PID controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  kdq:
    name: kdq
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kdq
    description: 'DELTAMODE: The q-axis differentiator gain for the current modulation
      PID controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  epA:
    name: epA
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: epA
    description: 'DELTAMODE: The real current error for phase A or triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  epB:
    name: epB
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: epB
    description: 'DELTAMODE: The real current error for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  epC:
    name: epC
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: epC
    description: 'DELTAMODE: The real current error for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  eqA:
    name: eqA
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: eqA
    description: 'DELTAMODE: The reactive current error for phase A or triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  eqB:
    name: eqB
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: eqB
    description: 'DELTAMODE: The reactive current error for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  eqC:
    name: eqC
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: eqC
    description: 'DELTAMODE: The reactive current error for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_epA:
    name: delta_epA
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_epA
    description: 'DELTAMODE: The change in real current error for phase A or triplex
      phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_epB:
    name: delta_epB
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_epB
    description: 'DELTAMODE: The change in real current error for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_epC:
    name: delta_epC
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_epC
    description: 'DELTAMODE: The change in real current error for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_eqA:
    name: delta_eqA
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_eqA
    description: 'DELTAMODE: The change in reactive current error for phase A or triplex
      phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_eqB:
    name: delta_eqB
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_eqB
    description: 'DELTAMODE: The change in reactive current error for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_eqC:
    name: delta_eqC
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_eqC
    description: 'DELTAMODE: The change in reactive current error for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  mdA:
    name: mdA
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mdA
    description: 'DELTAMODE: The d-axis current modulation for phase A or triplex
      phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  mdB:
    name: mdB
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mdB
    description: 'DELTAMODE: The d-axis current modulation for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  mdC:
    name: mdC
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mdC
    description: 'DELTAMODE: The d-axis current modulation for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  mqA:
    name: mqA
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mqA
    description: 'DELTAMODE: The q-axis current modulation for phase A or triplex
      phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  mqB:
    name: mqB
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mqB
    description: 'DELTAMODE: The q-axis current modulation for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  mqC:
    name: mqC
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mqC
    description: 'DELTAMODE: The q-axis current modulation for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_mdA:
    name: delta_mdA
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mdA
    description: 'DELTAMODE: The change in d-axis current modulation for phase A or
      triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_mdB:
    name: delta_mdB
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mdB
    description: 'DELTAMODE: The change in d-axis current modulation for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_mdC:
    name: delta_mdC
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mdC
    description: 'DELTAMODE: The change in d-axis current modulation for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_mqA:
    name: delta_mqA
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mqA
    description: 'DELTAMODE: The change in q-axis current modulation for phase A or
      triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_mqB:
    name: delta_mqB
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mqB
    description: 'DELTAMODE: The change in q-axis current modulation for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  delta_mqC:
    name: delta_mqC
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mqC
    description: 'DELTAMODE: The change in q-axis current modulation for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  IdqA:
    name: IdqA
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: IdqA
    description: 'DELTAMODE: The dq-axis current for phase A or triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  IdqB:
    name: IdqB
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: IdqB
    description: 'DELTAMODE: The dq-axis current for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  IdqC:
    name: IdqC
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: IdqC
    description: 'DELTAMODE: The dq-axis current for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  Tfreq_delay:
    name: Tfreq_delay
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tfreq_delay
    description: 'DELTAMODE: The time constant for delayed frequency seen by the inverter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  inverter_droop_fp:
    name: inverter_droop_fp
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: inverter_droop_fp
    description: 'DELTAMODE: Boolean used to indicate whether inverter f/p droop is
      included or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  R_fp:
    name: R_fp
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_fp
    description: 'DELTAMODE: The droop parameter of the f/p droop'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  kppmax:
    name: kppmax
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kppmax
    description: 'DELTAMODE: The proportional gain of Pmax controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  kipmax:
    name: kipmax
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kipmax
    description: 'DELTAMODE: The integral gain of Pmax controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  Pmax:
    name: Pmax
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pmax
    description: 'DELTAMODE: power limit of grid forming inverter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  Pmin:
    name: Pmin
    annotations:
      order:
        tag: order
        value: 93
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pmin
    description: 'DELTAMODE: power limit of grid forming inverter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  Pmax_Low_Limit:
    name: Pmax_Low_Limit
    annotations:
      order:
        tag: order
        value: 94
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pmax_Low_Limit
    description: 'DELTAMODE: output limit of Pmax controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  Tvol_delay:
    name: Tvol_delay
    annotations:
      order:
        tag: order
        value: 95
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tvol_delay
    description: 'DELTAMODE: The time constant for delayed voltage seen by the inverter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  inverter_droop_vq:
    name: inverter_droop_vq
    annotations:
      order:
        tag: order
        value: 96
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: inverter_droop_vq
    description: 'DELTAMODE: Boolean used to indicate whether inverter q/v droop is
      included or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  R_vq:
    name: R_vq
    annotations:
      order:
        tag: order
        value: 97
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_vq
    description: 'DELTAMODE: The droop parameter of the v/q droop'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  Tp_delay:
    name: Tp_delay
    annotations:
      order:
        tag: order
        value: 98
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tp_delay
    description: 'DELTAMODE: The time constant for delayed real power seen by the
      VSI droop controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  Tq_delay:
    name: Tq_delay
    annotations:
      order:
        tag: order
        value: 99
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tq_delay
    description: 'DELTAMODE: The time constant for delayed reactive power seen by
      the VSI droop controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  VSI_Rfilter:
    name: VSI_Rfilter
    annotations:
      order:
        tag: order
        value: 100
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: VSI_Rfilter[pu]
    description: VSI filter resistance (p.u.)
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: pu
  VSI_Xfilter:
    name: VSI_Xfilter
    annotations:
      order:
        tag: order
        value: 101
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: VSI_Xfilter[pu]
    description: VSI filter inductance (p.u.)
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: pu
  VSI_mode:
    name: VSI_mode
    annotations:
      order:
        tag: order
        value: 102
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: VSI_mode
    description: 'VSI MODEL: Selects VSI mode for either isochronous or droop one'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  VSI_freq:
    name: VSI_freq
    annotations:
      order:
        tag: order
        value: 103
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VSI_freq
    description: VSI frequency
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  ki_Vterminal:
    name: ki_Vterminal
    annotations:
      order:
        tag: order
        value: 104
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ki_Vterminal
    description: 'DELTAMODE: The integrator gain for the VSI terminal voltage modulation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  kp_Vterminal:
    name: kp_Vterminal
    annotations:
      order:
        tag: order
        value: 105
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kp_Vterminal
    description: 'DELTAMODE: The proportional gain for the VSI terminal voltage modulation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  V_set_droop:
    name: V_set_droop
    annotations:
      order:
        tag: order
        value: 106
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_set_droop
    description: 'DELTAMODE: The voltage setpoint of droop control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  V_set0:
    name: V_set0
    annotations:
      order:
        tag: order
        value: 107
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_set0
    description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  V_set1:
    name: V_set1
    annotations:
      order:
        tag: order
        value: 108
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_set1
    description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  V_set2:
    name: V_set2
    annotations:
      order:
        tag: order
        value: 109
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_set2
    description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  enable_ramp_rates_real:
    name: enable_ramp_rates_real
    annotations:
      order:
        tag: order
        value: 110
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: enable_ramp_rates_real
    description: 'DELTAMODE: Boolean used to indicate whether inverter ramp rate is
      enforced or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  max_ramp_up_real:
    name: max_ramp_up_real
    annotations:
      order:
        tag: order
        value: 111
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_ramp_up_real[W/s]
    description: 'DELTAMODE: The real power ramp up rate limit'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W/s
  max_ramp_down_real:
    name: max_ramp_down_real
    annotations:
      order:
        tag: order
        value: 112
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_ramp_down_real[W/s]
    description: 'DELTAMODE: The real power ramp down rate limit'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W/s
  enable_ramp_rates_reactive:
    name: enable_ramp_rates_reactive
    annotations:
      order:
        tag: order
        value: 113
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: enable_ramp_rates_reactive
    description: 'DELTAMODE: Boolean used to indicate whether inverter ramp rate is
      enforced or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  max_ramp_up_reactive:
    name: max_ramp_up_reactive
    annotations:
      order:
        tag: order
        value: 114
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_ramp_up_reactive[VAr/s]
    description: 'DELTAMODE: The reactive power ramp up rate limit'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: VAr/s
  max_ramp_down_reactive:
    name: max_ramp_down_reactive
    annotations:
      order:
        tag: order
        value: 115
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_ramp_down_reactive[VAr/s]
    description: 'DELTAMODE: The reactive power ramp down rate limit'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: VAr/s
  dynamic_model_mode:
    name: dynamic_model_mode
    annotations:
      order:
        tag: order
        value: 116
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: dynamic_model_mode
    description: 'DELTAMODE: Underlying model to use for deltamode control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  enable_1547_checks:
    name: enable_1547_checks
    annotations:
      order:
        tag: order
        value: 117
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: enable_1547_checks
    description: 'DELTAMODE: Enable IEEE 1547-2003 disconnect checking'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: boolean
    required: false
  reconnect_time:
    name: reconnect_time
    annotations:
      order:
        tag: order
        value: 118
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: reconnect_time[s]
    description: 'DELTAMODE: Time delay after IEEE 1547-2003 violation clears before
      resuming generation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - motor
    - performance_motor
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  inverter_1547_status:
    name: inverter_1547_status
    annotations:
      order:
        tag: order
        value: 119
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: inverter_1547_status
    description: 'DELTAMODE: Indicator if the inverter is curtailed due to a 1547
      violation or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: boolean
    required: false
  IEEE_1547_version:
    name: IEEE_1547_version
    annotations:
      order:
        tag: order
        value: 120
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: IEEE_1547_version
    description: 'DELTAMODE: Version of IEEE 1547 to use to populate defaults'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: Ieee1547Version
    required: false
  over_freq_high_cutout:
    name: over_freq_high_cutout
    annotations:
      order:
        tag: order
        value: 121
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_high_cutout[Hz]
    description: 'DELTAMODE: OF2 set point for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: Hz
  over_freq_high_disconnect_time:
    name: over_freq_high_disconnect_time
    annotations:
      order:
        tag: order
        value: 122
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_high_disconnect_time[s]
    description: 'DELTAMODE: OF2 clearing time for IEEE1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  over_freq_low_cutout:
    name: over_freq_low_cutout
    annotations:
      order:
        tag: order
        value: 123
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_low_cutout[Hz]
    description: 'DELTAMODE: OF1 set point for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: Hz
  over_freq_low_disconnect_time:
    name: over_freq_low_disconnect_time
    annotations:
      order:
        tag: order
        value: 124
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_low_disconnect_time[s]
    description: 'DELTAMODE: OF1 clearing time for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_freq_high_cutout:
    name: under_freq_high_cutout
    annotations:
      order:
        tag: order
        value: 125
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_high_cutout[Hz]
    description: 'DELTAMODE: UF2 set point for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: Hz
  under_freq_high_disconnect_time:
    name: under_freq_high_disconnect_time
    annotations:
      order:
        tag: order
        value: 126
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_high_disconnect_time[s]
    description: 'DELTAMODE: UF2 clearing time for IEEE1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_freq_low_cutout:
    name: under_freq_low_cutout
    annotations:
      order:
        tag: order
        value: 127
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_low_cutout[Hz]
    description: 'DELTAMODE: UF1 set point for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: Hz
  under_freq_low_disconnect_time:
    name: under_freq_low_disconnect_time
    annotations:
      order:
        tag: order
        value: 128
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_low_disconnect_time[s]
    description: 'DELTAMODE: UF1 clearing time for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_voltage_low_cutout:
    name: under_voltage_low_cutout
    annotations:
      order:
        tag: order
        value: 129
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_low_cutout[pu]
    description: Lowest voltage threshold for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  under_voltage_middle_cutout:
    name: under_voltage_middle_cutout
    annotations:
      order:
        tag: order
        value: 130
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_middle_cutout[pu]
    description: Middle-lowest voltage threshold for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  under_voltage_high_cutout:
    name: under_voltage_high_cutout
    annotations:
      order:
        tag: order
        value: 131
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_high_cutout[pu]
    description: High value of low voltage threshold for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  over_voltage_low_cutout:
    name: over_voltage_low_cutout
    annotations:
      order:
        tag: order
        value: 132
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_low_cutout[pu]
    description: Lowest voltage value for overvoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  over_voltage_high_cutout:
    name: over_voltage_high_cutout
    annotations:
      order:
        tag: order
        value: 133
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_high_cutout[pu]
    description: High voltage value for overvoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  under_voltage_low_disconnect_time:
    name: under_voltage_low_disconnect_time
    annotations:
      order:
        tag: order
        value: 134
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_low_disconnect_time[s]
    description: Lowest voltage clearing time for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_voltage_middle_disconnect_time:
    name: under_voltage_middle_disconnect_time
    annotations:
      order:
        tag: order
        value: 135
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_middle_disconnect_time[s]
    description: Middle-lowest voltage clearing time for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_voltage_high_disconnect_time:
    name: under_voltage_high_disconnect_time
    annotations:
      order:
        tag: order
        value: 136
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_high_disconnect_time[s]
    description: Highest voltage clearing time for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  over_voltage_low_disconnect_time:
    name: over_voltage_low_disconnect_time
    annotations:
      order:
        tag: order
        value: 137
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_low_disconnect_time[s]
    description: Lowest voltage clearing time for overvoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  over_voltage_high_disconnect_time:
    name: over_voltage_high_disconnect_time
    annotations:
      order:
        tag: order
        value: 138
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_high_disconnect_time[s]
    description: Highest voltage clearing time for overvoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  IEEE_1547_trip_method:
    name: IEEE_1547_trip_method
    annotations:
      order:
        tag: order
        value: 139
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: IEEE_1547_trip_method
    description: High over-voltage level trip
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - inverter_dyn
    range: Ieee1547TripMethod
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 140
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    description: The phases the inverter is attached to
    comments:
    - 'Import: A, B, C is wye to neutral (phases blank on three); S is s1s2 D across
      the legs at 240 V. Export: the letters then N; a split-phase bus''s letter then
      S.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    related_mappings:
    - cim:Terminal.phases
    - cim:PowerElectronicsConnection.phaseConnection
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  use_multipoint_efficiency:
    name: use_multipoint_efficiency
    annotations:
      order:
        tag: order
        value: 141
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: use_multipoint_efficiency
    description: 'FOUR QUADRANT MODEL: boolean to used the multipoint efficiency curve
      for the inverter when solar is attached'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  inverter_manufacturer:
    name: inverter_manufacturer
    annotations:
      order:
        tag: order
        value: 142
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inverter_manufacturer
    description: 'MULTIPOINT EFFICIENCY MODEL: the manufacturer of the inverter to
      setup up pre-existing efficiency curves'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  maximum_dc_power:
    name: maximum_dc_power
    annotations:
      order:
        tag: order
        value: 143
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_dc_power
    description: 'MULTIPOINT EFFICIENCY MODEL: the maximum dc power point for the
      efficiency curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  maximum_dc_voltage:
    name: maximum_dc_voltage
    annotations:
      order:
        tag: order
        value: 144
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_dc_voltage
    description: 'MULTIPOINT EFFICIENCY MODEL: the maximum dc voltage point for the
      efficiency curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  minimum_dc_power:
    name: minimum_dc_power
    annotations:
      order:
        tag: order
        value: 145
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: minimum_dc_power
    description: 'MULTIPOINT EFFICIENCY MODEL: the minimum dc power point for the
      efficiency curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  c_0:
    name: c_0
    annotations:
      order:
        tag: order
        value: 146
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: c_0
    description: 'MULTIPOINT EFFICIENCY MODEL: the first coefficient in the efficiency
      curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  c_1:
    name: c_1
    annotations:
      order:
        tag: order
        value: 147
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: c_1
    description: 'MULTIPOINT EFFICIENCY MODEL: the second coefficient in the efficiency
      curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  c_2:
    name: c_2
    annotations:
      order:
        tag: order
        value: 148
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: c_2
    description: 'MULTIPOINT EFFICIENCY MODEL: the third coefficient in the efficiency
      curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  c_3:
    name: c_3
    annotations:
      order:
        tag: order
        value: 149
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: c_3
    description: 'MULTIPOINT EFFICIENCY MODEL: the fourth coefficient in the efficiency
      curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  sense_object:
    name: sense_object
    annotations:
      order:
        tag: order
        value: 150
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: sense_object
    description: 'FOUR QUADRANT MODEL: name of the object the inverter is trying to
      mitigate the load on (node/link) in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  max_charge_rate:
    name: max_charge_rate
    annotations:
      order:
        tag: order
        value: 151
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_charge_rate[W]
    description: 'FOUR QUADRANT MODEL: maximum rate the battery can be charged in
      LOAD_FOLLOWING'
    comments:
    - 'Import: StorageInverterInfo.chargeRateActiveMax (W), a nameplate GridLAB-D
      reads only in load following. Export: chargeRateActiveMax x the unit''s share.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    exact_mappings:
    - cim:StorageInverterInfo.chargeRateActiveMax
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  max_discharge_rate:
    name: max_discharge_rate
    annotations:
      order:
        tag: order
        value: 152
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_discharge_rate[W]
    description: 'FOUR QUADRANT MODEL: maximum rate the battery can be discharged
      in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  charge_on_threshold:
    name: charge_on_threshold
    annotations:
      order:
        tag: order
        value: 153
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: charge_on_threshold[W]
    description: 'FOUR QUADRANT MODEL: power level at which the inverter should try
      charging the battery in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  charge_off_threshold:
    name: charge_off_threshold
    annotations:
      order:
        tag: order
        value: 154
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: charge_off_threshold[W]
    description: 'FOUR QUADRANT MODEL: power level at which the inverter should cease
      charging the battery in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  discharge_on_threshold:
    name: discharge_on_threshold
    annotations:
      order:
        tag: order
        value: 155
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: discharge_on_threshold[W]
    description: 'FOUR QUADRANT MODEL: power level at which the inverter should try
      discharging the battery in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  discharge_off_threshold:
    name: discharge_off_threshold
    annotations:
      order:
        tag: order
        value: 156
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: discharge_off_threshold[W]
    description: 'FOUR QUADRANT MODEL: power level at which the inverter should cease
      discharging the battery in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  excess_input_power:
    name: excess_input_power
    annotations:
      order:
        tag: order
        value: 157
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: excess_input_power[W]
    description: 'FOUR QUADRANT MODEL: Excess power at the input of the inverter that
      is otherwise just lost, or could be shunted to a battery'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  charge_lockout_time:
    name: charge_lockout_time
    annotations:
      order:
        tag: order
        value: 158
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: charge_lockout_time[s]
    description: 'FOUR QUADRANT MODEL: Lockout time when a charging operation occurs
      before another LOAD_FOLLOWING dispatch operation can occur'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  discharge_lockout_time:
    name: discharge_lockout_time
    annotations:
      order:
        tag: order
        value: 159
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: discharge_lockout_time[s]
    description: 'FOUR QUADRANT MODEL: Lockout time when a discharging operation occurs
      before another LOAD_FOLLOWING dispatch operation can occur'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  pf_reg_activate:
    name: pf_reg_activate
    annotations:
      order:
        tag: order
        value: 160
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_activate
    description: 'FOUR QUADRANT MODEL: Lowest acceptable power-factor level below
      which power-factor regulation will activate.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_deactivate:
    name: pf_reg_deactivate
    annotations:
      order:
        tag: order
        value: 161
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_deactivate
    description: 'FOUR QUADRANT MODEL: Lowest acceptable power-factor above which
      no power-factor regulation is needed.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pf_target:
    name: pf_target
    annotations:
      order:
        tag: order
        value: 162
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_target
    description: 'FOUR QUADRANT MODEL: Desired power-factor to maintain (signed) positive
      is inductive'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_high:
    name: pf_reg_high
    annotations:
      order:
        tag: order
        value: 163
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_high
    description: 'FOUR QUADRANT MODEL: Upper limit for power-factor - if exceeds,
      go full reverse reactive'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_low:
    name: pf_reg_low
    annotations:
      order:
        tag: order
        value: 164
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_low
    description: 'FOUR QUADRANT MODEL: Lower limit for power-factor - if exceeds,
      stop regulating - pf_target_var is below this'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_activate_lockout_time:
    name: pf_reg_activate_lockout_time
    annotations:
      order:
        tag: order
        value: 165
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_activate_lockout_time[s]
    description: 'FOUR QUADRANT MODEL: Mandatory pause between the deactivation of
      power-factor regulation and it reactivation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  disable_volt_var_if_no_input_power:
    name: disable_volt_var_if_no_input_power
    annotations:
      order:
        tag: order
        value: 166
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: disable_volt_var_if_no_input_power
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  delay_time:
    name: delay_time
    annotations:
      order:
        tag: order
        value: 167
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delay_time[s]
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  max_var_slew_rate:
    name: max_var_slew_rate
    annotations:
      order:
        tag: order
        value: 168
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_var_slew_rate[VAr/s]
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: VAr/s
  max_pwr_slew_rate:
    name: max_pwr_slew_rate
    annotations:
      order:
        tag: order
        value: 169
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_pwr_slew_rate[W/s]
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W/s
  volt_var_sched:
    name: volt_var_sched
    annotations:
      order:
        tag: order
        value: 170
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: volt_var_sched
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  freq_pwr_sched:
    name: freq_pwr_sched
    annotations:
      order:
        tag: order
        value: 171
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: freq_pwr_sched
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  charge_threshold:
    name: charge_threshold
    annotations:
      order:
        tag: order
        value: 172
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: charge_threshold[W]
    description: 'FOUR QUADRANT MODEL: Level at which all inverters in the group will
      begin charging attached batteries. Regulated minimum load level.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  discharge_threshold:
    name: discharge_threshold
    annotations:
      order:
        tag: order
        value: 173
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: discharge_threshold[W]
    description: 'FOUR QUADRANT MODEL: Level at which all inverters in the group will
      begin discharging attached batteries. Regulated maximum load level.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  group_max_charge_rate:
    name: group_max_charge_rate
    annotations:
      order:
        tag: order
        value: 174
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: group_max_charge_rate[W]
    description: 'FOUR QUADRANT MODEL: Sum of the charge rates of the batteries involved
      in the group load-following.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  group_max_discharge_rate:
    name: group_max_discharge_rate
    annotations:
      order:
        tag: order
        value: 175
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: group_max_discharge_rate[W]
    description: 'FOUR QUADRANT MODEL: Sum of the discharge rates of the batteries
      involved in the group load-following.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  group_rated_power:
    name: group_rated_power
    annotations:
      order:
        tag: order
        value: 176
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: group_rated_power[W]
    description: 'FOUR QUADRANT MODEL: Sum of the inverter power ratings of the inverters
      involved in the group power-factor regulation.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  V_base:
    name: V_base
    annotations:
      order:
        tag: order
        value: 177
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_base[V]
    description: 'FOUR QUADRANT MODEL: The base voltage on the grid side of the inverter.
      Used in VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: V
  V1:
    name: V1
    annotations:
      order:
        tag: order
        value: 178
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V1[pu]
    description: 'FOUR QUADRANT MODEL: voltage point 1 in volt/var curve. Used in
      VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  Q1:
    name: Q1
    annotations:
      order:
        tag: order
        value: 179
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q1[pu]
    description: 'FOUR QUADRANT MODEL: VAR point 1 in volt/var curve. Used in VOLT_VAR
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  V2:
    name: V2
    annotations:
      order:
        tag: order
        value: 180
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V2[pu]
    description: 'FOUR QUADRANT MODEL: voltage point 2 in volt/var curve. Used in
      VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  Q2:
    name: Q2
    annotations:
      order:
        tag: order
        value: 181
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q2[pu]
    description: 'FOUR QUADRANT MODEL: VAR point 2 in volt/var curve. Used in VOLT_VAR
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  V3:
    name: V3
    annotations:
      order:
        tag: order
        value: 182
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V3[pu]
    description: 'FOUR QUADRANT MODEL: voltage point 3 in volt/var curve. Used in
      VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  Q3:
    name: Q3
    annotations:
      order:
        tag: order
        value: 183
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q3[pu]
    description: 'FOUR QUADRANT MODEL: VAR point 3 in volt/var curve. Used in VOLT_VAR
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  V4:
    name: V4
    annotations:
      order:
        tag: order
        value: 184
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V4[pu]
    description: 'FOUR QUADRANT MODEL: voltage point 4 in volt/var curve. Used in
      VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  Q4:
    name: Q4
    annotations:
      order:
        tag: order
        value: 185
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q4[pu]
    description: 'FOUR QUADRANT MODEL: VAR point 4 in volt/var curve. Used in VOLT_VAR
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  volt_var_control_lockout:
    name: volt_var_control_lockout
    annotations:
      order:
        tag: order
        value: 186
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: volt_var_control_lockout[s]
    description: 'FOUR QUADRANT QUADRANT MODEL: the lockout time between volt/var
      actions.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  number_of_phases_out:
    name: number_of_phases_out
    annotations:
      order:
        tag: order
        value: 187
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: number_of_phases_out
    description: Exposed variable - hidden for solar
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: integer
    required: false
  efficiency_value:
    name: efficiency_value
    annotations:
      order:
        tag: order
        value: 188
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: efficiency_value
    description: Exposed variable - hidden for solar
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  VW_V1:
    name: VW_V1
    annotations:
      order:
        tag: order
        value: 189
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VW_V1[pu]
    description: 'FOUR QUADRANT MODEL: Voltage at which power limiting begins (e.g.
      1.0583). Used in VOLT_WATT control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  VW_V2:
    name: VW_V2
    annotations:
      order:
        tag: order
        value: 190
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VW_V2[pu]
    description: 'FOUR QUADRANT MODEL: Voltage at which power limiting ends. (e.g.
      1.1000). Used in VOLT_WATT control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  VW_P1:
    name: VW_P1
    annotations:
      order:
        tag: order
        value: 191
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VW_P1[pu]
    description: 'FOUR QUADRANT MODEL: Power limit at VW_P1 (e.g. 1). Used in VOLT_WATT
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  VW_P2:
    name: VW_P2
    annotations:
      order:
        tag: order
        value: 192
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VW_P2[pu]
    description: 'FOUR QUADRANT MODEL: Power limit at VW_P2 (e.g. 0). Used in VOLT_WATT
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  WT_is_connected:
    name: WT_is_connected
    annotations:
      order:
        tag: order
        value: 193
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: WT_is_connected
    description: Internal flag that indicates a wind turbine child is connected
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  pf_reg_status:
    name: pf_reg_status
    annotations:
      order:
        tag: order
        value: 194
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: pf_reg_status
    description: 'CHECKPOINT_VAR: internal variable for pf_reg_status'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  load_follow_status:
    name: load_follow_status
    annotations:
      order:
        tag: order
        value: 195
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: load_follow_status
    description: 'CHECKPOINT_VAR: Status variable for what the load_following mode
      is doing'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  last_current_A:
    name: last_current_A
    annotations:
      order:
        tag: order
        value: 196
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_current_A
    description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
      from parent so XML files look proper) - element 0'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_current_B:
    name: last_current_B
    annotations:
      order:
        tag: order
        value: 197
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_current_B
    description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
      from parent so XML files look proper) - element 1'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_current_C:
    name: last_current_C
    annotations:
      order:
        tag: order
        value: 198
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_current_C
    description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
      from parent so XML files look proper) - element 2'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_current_D:
    name: last_current_D
    annotations:
      order:
        tag: order
        value: 199
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_current_D
    description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
      from parent so XML files look proper) - element 3'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_power_A:
    name: last_power_A
    annotations:
      order:
        tag: order
        value: 200
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_power_A
    description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
      - used to remove from parent so XML looks right - element 0'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_power_B:
    name: last_power_B
    annotations:
      order:
        tag: order
        value: 201
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_power_B
    description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
      - used to remove from parent so XML looks right - element 1'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_power_C:
    name: last_power_C
    annotations:
      order:
        tag: order
        value: 202
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_power_C
    description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
      - used to remove from parent so XML looks right - element 2'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_power_D:
    name: last_power_D
    annotations:
      order:
        tag: order
        value: 203
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_power_D
    description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
      - used to remove from parent so XML looks right - element 3'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  inverter_first_step:
    name: inverter_first_step
    annotations:
      order:
        tag: order
        value: 204
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: inverter_first_step
    description: 'CHECKPOINT_VAR: internal variable for inverter_first_step'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  first_iteration_current_injection:
    name: first_iteration_current_injection
    annotations:
      order:
        tag: order
        value: 205
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: first_iteration_current_injection
    description: 'CHECKPOINT_VAR: Initialization variable - mostly so SWING_PQ buses
      initalize properly for deltamode'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: integer
    required: false
  m12:
    name: m12
    annotations:
      order:
        tag: order
        value: 206
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: m12
    description: 'CHECKPOINT_VAR: internal variable for m12'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  b12:
    name: b12
    annotations:
      order:
        tag: order
        value: 207
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b12
    description: 'CHECKPOINT_VAR: internal variable for b12'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  m23:
    name: m23
    annotations:
      order:
        tag: order
        value: 208
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: m23
    description: 'CHECKPOINT_VAR: internal variable for m23'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  b23:
    name: b23
    annotations:
      order:
        tag: order
        value: 209
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b23
    description: 'CHECKPOINT_VAR: internal variable for b23'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  m34:
    name: m34
    annotations:
      order:
        tag: order
        value: 210
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: m34
    description: 'CHECKPOINT_VAR: internal variable for m34'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  b34:
    name: b34
    annotations:
      order:
        tag: order
        value: 211
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b34
    description: 'CHECKPOINT_VAR: internal variable for b34'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  allowed_vv_action:
    name: allowed_vv_action
    annotations:
      order:
        tag: order
        value: 212
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: allowed_vv_action
    description: 'CHECKPOINT_VAR: internal variable for allowed_vv_action'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  last_vv_check:
    name: last_vv_check
    annotations:
      order:
        tag: order
        value: 213
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: last_vv_check
    description: 'CHECKPOINT_VAR: internal variable for last_vv_check'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  IEEE_1547_STATUS:
    name: IEEE_1547_STATUS
    annotations:
      order:
        tag: order
        value: 214
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: IEEE_1547_STATUS
    description: 'CHECKPOINT_VAR: internal variable for ieee_1547_version'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  over_freq_high_band_viol_time:
    name: over_freq_high_band_viol_time
    annotations:
      order:
        tag: order
        value: 215
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_high_band_viol_time
    description: 'CHECKPOINT_VAR: OF2 violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  over_freq_low_band_viol_time:
    name: over_freq_low_band_viol_time
    annotations:
      order:
        tag: order
        value: 216
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_low_band_viol_time
    description: 'CHECKPOINT_VAR: OF1 violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  under_freq_low_band_viol_time:
    name: under_freq_low_band_viol_time
    annotations:
      order:
        tag: order
        value: 217
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_low_band_viol_time
    description: 'CHECKPOINT_VAR: UF1 violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  under_voltage_lowest_viol_time:
    name: under_voltage_lowest_viol_time
    annotations:
      order:
        tag: order
        value: 218
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_lowest_viol_time
    description: 'CHECKPOINT_VAR: Lowest low voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  under_voltage_middle_viol_time:
    name: under_voltage_middle_viol_time
    annotations:
      order:
        tag: order
        value: 219
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_middle_viol_time
    description: 'CHECKPOINT_VAR: Middle low voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  under_voltage_high_viol_time:
    name: under_voltage_high_viol_time
    annotations:
      order:
        tag: order
        value: 220
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_high_viol_time
    description: 'CHECKPOINT_VAR: Highest low voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  over_voltage_low_viol_time:
    name: over_voltage_low_viol_time
    annotations:
      order:
        tag: order
        value: 221
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_low_viol_time
    description: 'CHECKPOINT_VAR: Lowest high voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  over_voltage_high_viol_time:
    name: over_voltage_high_viol_time
    annotations:
      order:
        tag: order
        value: 222
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_high_viol_time
    description: 'CHECKPOINT_VAR: Highest high voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  lf_dispatch_power:
    name: lf_dispatch_power
    annotations:
      order:
        tag: order
        value: 223
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: lf_dispatch_power
    description: 'CHECKPOINT_VAR: Amount of real power to try and dispatch to meet
      thresholds'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  next_update_time:
    name: next_update_time
    annotations:
      order:
        tag: order
        value: 224
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: next_update_time
    description: 'CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  lf_dispatch_change_allowed:
    name: lf_dispatch_change_allowed
    annotations:
      order:
        tag: order
        value: 225
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: lf_dispatch_change_allowed
    description: 'CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  pf_reg_dispatch_change_allowed:
    name: pf_reg_dispatch_change_allowed
    annotations:
      order:
        tag: order
        value: 226
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: pf_reg_dispatch_change_allowed
    description: 'CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed
      for power factor regulation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  pf_reg_dispatch_VAR:
    name: pf_reg_dispatch_VAR
    annotations:
      order:
        tag: order
        value: 227
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_dispatch_VAR
    description: 'CHECKPOINT_VAR: (Reactive only?) power dispatched to meet power
      factor regulation threshold'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_next_update_time:
    name: pf_reg_next_update_time
    annotations:
      order:
        tag: order
        value: 228
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: pf_reg_next_update_time
    description: 'CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  prev_time:
    name: prev_time
    annotations:
      order:
        tag: order
        value: 229
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: prev_time
    description: 'CHECKPOINT_VAR: Tracking variable for previous "new time" run'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - battery
    - inverter
    range: string
    required: false
  prev_time_dbl:
    name: prev_time_dbl
    annotations:
      order:
        tag: order
        value: 230
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: prev_time_dbl
    description: 'CHECKPOINT_VAR: Tracking variable for 1547 checks and ramp rates'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - evcharger_det
    range: float
    required: false
  event_deltat:
    name: event_deltat
    annotations:
      order:
        tag: order
        value: 231
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: event_deltat
    description: 'CHECKPOINT_VAR: Event-driven delta-t variable'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  start_time:
    name: start_time
    annotations:
      order:
        tag: order
        value: 232
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: start_time
    description: 'CHECKPOINT_VAR: Recording start time of simulation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    - dryer
    - refrigerator
    range: string
    required: false
  last_I_Out_A:
    name: last_I_Out_A
    annotations:
      order:
        tag: order
        value: 233
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_I_Out_A
    description: 'CHECKPOINT_VAR: internal variable for last_I_Out[0]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_I_Out_B:
    name: last_I_Out_B
    annotations:
      order:
        tag: order
        value: 234
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_I_Out_B
    description: 'CHECKPOINT_VAR: internal variable for last_I_Out[1]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_I_Out_C:
    name: last_I_Out_C
    annotations:
      order:
        tag: order
        value: 235
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_I_Out_C
    description: 'CHECKPOINT_VAR: internal variable for last_I_Out[2]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  last_I_In:
    name: last_I_In
    annotations:
      order:
        tag: order
        value: 236
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: last_I_In
    description: 'CHECKPOINT_VAR: internal variable for last_I_In'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pa_vw_limited:
    name: pa_vw_limited
    annotations:
      order:
        tag: order
        value: 237
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pa_vw_limited
    description: 'CHECKPOINT_VAR: internal variable for pa_vw_limited'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pb_vw_limited:
    name: pb_vw_limited
    annotations:
      order:
        tag: order
        value: 238
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pb_vw_limited
    description: 'CHECKPOINT_VAR: internal variable for pb_vw_limited'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  pc_vw_limited:
    name: pc_vw_limited
    annotations:
      order:
        tag: order
        value: 239
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pc_vw_limited
    description: 'CHECKPOINT_VAR: internal variable for pc_vw_limited'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  out_of_violation_time_total:
    name: out_of_violation_time_total
    annotations:
      order:
        tag: order
        value: 240
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: out_of_violation_time_total
    description: 'CHECKPOINT_VAR: internal variable for out_of_violation_time_total'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: float
    required: false
  deltamode_inclusive:
    name: deltamode_inclusive
    annotations:
      order:
        tag: order
        value: 241
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: deltamode_inclusive
    description: 'CHECKPOINT_VAR: Boolean for deltamode calls - pulled from object
      flags'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  first_sync_delta_enabled:
    name: first_sync_delta_enabled
    annotations:
      order:
        tag: order
        value: 242
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: first_sync_delta_enabled
    description: 'CHECKPOINT_VAR: internal variable for first_sync_delta_enabled'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: boolean
    required: false
  first_iter_counter:
    name: first_iter_counter
    annotations:
      order:
        tag: order
        value: 243
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: first_iter_counter
    description: 'CHECKPOINT_VAR: internal variable for first_iter_counter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: string
    required: false
  first_run:
    name: first_run
    annotations:
      order:
        tag: order
        value: 244
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: first_run
    description: 'CHECKPOINT_VAR: internal variable for first_run'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    domain_of:
    - controller_dg
    - inverter
    range: boolean
    required: false
  prev_value_IGenerated_A:
    name: prev_value_IGenerated_A
    annotations:
      order:
        tag: order
        value: 245
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_value_IGenerated_A
    description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[0]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  prev_value_IGenerated_B:
    name: prev_value_IGenerated_B
    annotations:
      order:
        tag: order
        value: 246
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_value_IGenerated_B
    description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[1]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false
  prev_value_IGenerated_C:
    name: prev_value_IGenerated_C
    annotations:
      order:
        tag: order
        value: 247
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_value_IGenerated_C
    description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[2]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    domain_of:
    - inverter
    range: Complex
    required: false

Induced

name: inverter
description: 'Copyright (C) 2008 Battelle Memorial Institute

  @file inverter.cpp

  @defgroup inverter

  @ingroup generators

  @{


  Inherits from: gld_object


  Type: Instance (network topology element)


  Note: Inherits from gld_object (not in generators module)'
comments:
- 'Import: PowerElectronicsConnection, mRID pv_ or storage_ + name by its solar or
  battery child (inverter.cimtbl), with a GenerationInverterInfo or StorageInverterInfo
  datasheet; one child is mapped, GridLAB-D has no delta inverter. Export: each PowerElectronicsConnection,
  one inverter per unit (name_<n> when several), parented to its bus.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PowerElectronicsConnection
close_mappings:
- cim:GenerationInverterInfo
- cim:StorageInverterInfo
is_a: glm_object
attributes:
  inverter_type:
    name: inverter_type
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inverter_type
    description: 'LEGACY MODEL: Sets efficiencies and other parameters; if using four_quadrant_control_mode,
      set this to FOUR_QUADRANT'
    comments:
    - 'Import: structural; FOUR_QUADRANT only, any other raises (unset is GridLAB-D''s
      PWM). Export: FOUR_QUADRANT.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  four_quadrant_control_mode:
    name: four_quadrant_control_mode
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: four_quadrant_control_mode
    description: 'FOUR QUADRANT MODEL: Activates various control modes'
    comments:
    - 'Import: structural; CONSTANT_PF on a solar, CONSTANT_PQ on a battery (which
      also reads CONSTANT_PF), others raise; the mode''s capability flag goes in the
      row comment, InverterCapabilities is not written yet. Export: CONSTANT_PQ on
      a battery, CONSTANT_PF on a PV.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  pf_reg:
    name: pf_reg
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: pf_reg
    description: Activate (or not) power factor regulation in four_quadrant_control_mode
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  generator_status:
    name: generator_status
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: generator_status
    description: describes whether the generator is online or offline
    comments:
    - 'Import: ONLINE (default) is normallyInService true, OFFLINE false and the output
      0. Export: OFFLINE when normallyInService is false, else ONLINE.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:Equipment.normallyInService
    owner: inverter
    domain_of:
    - battery
    - inverter
    range: string
    required: false
  generator_mode:
    name: generator_mode
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: generator_mode
    description: 'LEGACY MODEL: Selects generator control mode when using legacy model;
      in non-legacy models, this should be SUPPLY_DRIVEN.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - battery
    - inverter
    - rectifier
    range: GeneratorMode
    required: false
  inverter_convergence_criterion:
    name: inverter_convergence_criterion
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: inverter_convergence_criterion
    description: The maximum change in error threshold for exitting deltamode.
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  current_convergence:
    name: current_convergence
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_convergence[A]
    description: Convergence criterion for current changes on first timestep - basically
      initialization of system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - diesel_dg
    - inverter
    range: float
    required: false
    unit:
      ucum_code: A
  V_In:
    name: V_In
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_In[V]
    description: DC voltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: V
  I_In:
    name: I_In
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: I_In[A]
    description: DC current
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - battery
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: A
  P_In:
    name: P_In
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: P_In[W]
    description: DC power
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: W
  VA_Out:
    name: VA_Out
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: VA_Out[VA]
    description: AC power
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - battery
    - inverter
    - inverter_dyn
    - rectifier
    range: Complex
    required: false
    unit:
      ucum_code: VA
  Vdc:
    name: Vdc
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Vdc[V]
    description: 'LEGACY MODEL: DC voltage'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: V
  phaseA_V_Out:
    name: phaseA_V_Out
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseA_V_Out[V]
    description: AC voltage on A phase in three-phase system; 240-V connection on
      a triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseB_V_Out:
    name: phaseB_V_Out
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseB_V_Out[V]
    description: AC voltage on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseC_V_Out:
    name: phaseC_V_Out
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseC_V_Out[V]
    description: AC voltage on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseA_I_Out:
    name: phaseA_I_Out
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseA_I_Out[V]
    description: AC current on A phase in three-phase system; 240-V connection on
      a triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseB_I_Out:
    name: phaseB_I_Out
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseB_I_Out[V]
    description: AC current on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: Complex
    required: false
    unit:
      ucum_code: V
  phaseC_I_Out:
    name: phaseC_I_Out
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseC_I_Out[V]
    description: AC current on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: Complex
    required: false
    unit:
      ucum_code: V
  power_A:
    name: power_A
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_A[VA]
    description: AC power on A phase in three-phase system; 240-V connection on a
      triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_B:
    name: power_B
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_B[VA]
    description: AC power on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_C:
    name: power_C
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_C[VA]
    description: AC power on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  curr_VA_out_A:
    name: curr_VA_out_A
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: curr_VA_out_A[VA]
    description: AC power on A phase in three-phase system; 240-V connection on a
      triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  curr_VA_out_B:
    name: curr_VA_out_B
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: curr_VA_out_B[VA]
    description: AC power on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  curr_VA_out_C:
    name: curr_VA_out_C
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: curr_VA_out_C[VA]
    description: AC power on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  prev_VA_out_A:
    name: prev_VA_out_A
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_VA_out_A[VA]
    description: AC power on A phase in three-phase system; 240-V connection on a
      triplex system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  prev_VA_out_B:
    name: prev_VA_out_B
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_VA_out_B[VA]
    description: AC power on B phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  prev_VA_out_C:
    name: prev_VA_out_C
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_VA_out_C[VA]
    description: AC power on C phase in three-phase system
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  e_source_A:
    name: e_source_A
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: e_source_A
    description: 'DELTAMODE: Internal voltage of grid-forming source, phase A'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  e_source_B:
    name: e_source_B
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: e_source_B
    description: 'DELTAMODE: Internal voltage of grid-forming source, phase B'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  e_source_C:
    name: e_source_C
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: e_source_C
    description: 'DELTAMODE: Internal voltage of grid-forming source, phase C'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  V_angle_A:
    name: V_angle_A
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_angle_A
    description: 'DELTAMODE: Internal angle of grid-forming source, phase A'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  V_angle_B:
    name: V_angle_B
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_angle_B
    description: 'DELTAMODE: Internal angle of grid-forming source, phase B'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  V_angle_C:
    name: V_angle_C
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_angle_C
    description: 'DELTAMODE: Internal angle of grid-forming source, phase C'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  phaseA_I_Forming:
    name: phaseA_I_Forming
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseA_I_Forming[A]
    description: AC current on A phase in three-phase system, only for grid_forming
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseB_I_Forming:
    name: phaseB_I_Forming
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseB_I_Forming[A]
    description: AC current on B phase in three-phase system, only for grid_forming
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseC_I_Forming:
    name: phaseC_I_Forming
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseC_I_Forming[A]
    description: AC current on C phase in three-phase system, only for grid_forming
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseA_I_Following:
    name: phaseA_I_Following
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseA_I_Following[A]
    description: AC current on A phase in three-phase system, only for grid_following
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseB_I_Following:
    name: phaseB_I_Following
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseB_I_Following[A]
    description: AC current on B phase in three-phase system, only for grid_following
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  phaseC_I_Following:
    name: phaseC_I_Following
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: phaseC_I_Following[A]
    description: AC current on C phase in three-phase system, only for grid_following
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: A
  pCircuit_V_Avg:
    name: pCircuit_V_Avg
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pCircuit_V_Avg
    description: 'DELTAMODE: three-phase average value of terminal voltage'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  P_Out:
    name: P_Out
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: P_Out[VA]
    description: 'FOUR QUADRANT MODEL: Scheduled real power out in CONSTANT_PQ control
      mode'
    comments:
    - 'Import: a battery''s CONSTANT_PQ set point, limited by ratedS, a full battery
      or the reserve, is p (W, load sign) and gives batteryState; a PV''s is an output
      GridLAB-D overwrites, so only in the row comment. Export: a battery''s p from
      get_inverter_units, generation sign.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.p
    - cim:BatteryUnit.batteryState
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - solar
    range: float
    required: false
    unit:
      ucum_code: VA
  Q_Out:
    name: Q_Out
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q_Out[VAr]
    description: 'FOUR QUADRANT MODEL: Schedule reactive power out in CONSTANT_PQ
      control mode'
    comments:
    - 'Import: q (VAr) is 0 when unset or 0; any other value raises. Export: a battery''s
      q, generation sign.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.q
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: VAr
  power_in:
    name: power_in
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_in[W]
    description: 'LEGACY MODEL: No longer used'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - link
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  rated_power:
    name: rated_power
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: rated_power[VA]
    description: 'FOUR QUADRANT MODEL: The rated power of the inverter'
    comments:
    - 'Import: ratedS (VA) = rated_power x the phases out (3, 2, 1; S is 1); maxQ
      = -minQ = ratedS, and the datasheet''s apparentPowerMaximum; unset or 0 raises.
      Export: ratedS x the unit''s share / phases.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.ratedS
    - cim:PowerElectronicsConnection.maxQ
    - cim:PowerElectronicsConnection.minQ
    - cim:GridEdgeDeviceInfo.apparentPowerMaximum
    owner: inverter
    domain_of:
    - battery
    - inverter
    - inverter_dyn
    - solar
    range: float
    required: false
    unit:
      ucum_code: VA
  rated_battery_power:
    name: rated_battery_power
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: rated_battery_power[W]
    description: 'FOUR QUADRANT MODEL: The rated power of battery when battery is
      attached'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  inverter_efficiency:
    name: inverter_efficiency
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: inverter_efficiency
    description: 'FOUR QUADRANT MODEL: The efficiency of the inverter'
    comments:
    - 'Import: PV AC = DC x inverter_efficiency (default 0.9) is folded into p; CIM
      has no inverter efficiency. Export: 1 on a PV; the losses are in p.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.p
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  battery_soc:
    name: battery_soc
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: battery_soc[pu]
    description: 'FOUR QUADRANT MODEL: The state of charge of an attached battery'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  soc_reserve:
    name: soc_reserve
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: soc_reserve[pu]
    description: 'FOUR QUADRANT MODEL: The reserve state of charge of an attached
      battery for islanding cases'
    comments:
    - 'Import: BatteryUnit.minimumE (Wh) = soc_reserve x battery_capacity; default
      0. Export: minimumE / ratedE.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:BatteryUnit.minimumE
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  power_factor:
    name: power_factor
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_factor[unit]
    description: 'FOUR QUADRANT MODEL: The power factor used for CONSTANT_PF control
      mode'
    comments:
    - 'Import: CONSTANT_PF q is 0 when |pf| is 1; |pf| < 1 raises. Export: a PV''s
      p / |p + jq|, negative when q is.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    close_mappings:
    - cim:PowerElectronicsConnection.q
    owner: inverter
    domain_of:
    - performance_motor
    - battery
    - inverter
    - windturb_dg
    - residential_enduse
    range: float
    required: false
    unit:
      ucum_code: unit
  islanded_state:
    name: islanded_state
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: islanded_state
    description: 'FOUR QUADRANT MODEL: Boolean used to let control modes to act under
      island conditions'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  nominal_frequency:
    name: nominal_frequency
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_frequency[Hz]
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: Hz
  Pref:
    name: Pref
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pref
    description: 'DELTAMODE: The real power reference.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - diesel_dg
    - inverter
    - inverter_dyn
    range: float
    required: false
  Qref:
    name: Qref
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Qref
    description: 'DELTAMODE: The reactive power reference.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - diesel_dg
    - inverter
    - inverter_dyn
    range: float
    required: false
  kpd:
    name: kpd
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kpd
    description: 'DELTAMODE: The d-axis integration gain for the current modulation
      PI controller.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  kpq:
    name: kpq
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kpq
    description: 'DELTAMODE: The q-axis integration gain for the current modulation
      PI controller.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  kid:
    name: kid
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kid
    description: 'DELTAMODE: The d-axis proportional gain for the current modulation
      PI controller.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  kiq:
    name: kiq
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kiq
    description: 'DELTAMODE: The q-axis proportional gain for the current modulation
      PI controller.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  kdd:
    name: kdd
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kdd
    description: 'DELTAMODE: The d-axis differentiator gain for the current modulation
      PID controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  kdq:
    name: kdq
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kdq
    description: 'DELTAMODE: The q-axis differentiator gain for the current modulation
      PID controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  epA:
    name: epA
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: epA
    description: 'DELTAMODE: The real current error for phase A or triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  epB:
    name: epB
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: epB
    description: 'DELTAMODE: The real current error for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  epC:
    name: epC
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: epC
    description: 'DELTAMODE: The real current error for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  eqA:
    name: eqA
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: eqA
    description: 'DELTAMODE: The reactive current error for phase A or triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  eqB:
    name: eqB
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: eqB
    description: 'DELTAMODE: The reactive current error for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  eqC:
    name: eqC
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: eqC
    description: 'DELTAMODE: The reactive current error for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_epA:
    name: delta_epA
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_epA
    description: 'DELTAMODE: The change in real current error for phase A or triplex
      phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_epB:
    name: delta_epB
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_epB
    description: 'DELTAMODE: The change in real current error for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_epC:
    name: delta_epC
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_epC
    description: 'DELTAMODE: The change in real current error for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_eqA:
    name: delta_eqA
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_eqA
    description: 'DELTAMODE: The change in reactive current error for phase A or triplex
      phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_eqB:
    name: delta_eqB
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_eqB
    description: 'DELTAMODE: The change in reactive current error for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_eqC:
    name: delta_eqC
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_eqC
    description: 'DELTAMODE: The change in reactive current error for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  mdA:
    name: mdA
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mdA
    description: 'DELTAMODE: The d-axis current modulation for phase A or triplex
      phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  mdB:
    name: mdB
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mdB
    description: 'DELTAMODE: The d-axis current modulation for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  mdC:
    name: mdC
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mdC
    description: 'DELTAMODE: The d-axis current modulation for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  mqA:
    name: mqA
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mqA
    description: 'DELTAMODE: The q-axis current modulation for phase A or triplex
      phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  mqB:
    name: mqB
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mqB
    description: 'DELTAMODE: The q-axis current modulation for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  mqC:
    name: mqC
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mqC
    description: 'DELTAMODE: The q-axis current modulation for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_mdA:
    name: delta_mdA
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mdA
    description: 'DELTAMODE: The change in d-axis current modulation for phase A or
      triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_mdB:
    name: delta_mdB
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mdB
    description: 'DELTAMODE: The change in d-axis current modulation for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_mdC:
    name: delta_mdC
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mdC
    description: 'DELTAMODE: The change in d-axis current modulation for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_mqA:
    name: delta_mqA
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mqA
    description: 'DELTAMODE: The change in q-axis current modulation for phase A or
      triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_mqB:
    name: delta_mqB
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mqB
    description: 'DELTAMODE: The change in q-axis current modulation for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  delta_mqC:
    name: delta_mqC
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delta_mqC
    description: 'DELTAMODE: The change in q-axis current modulation for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  IdqA:
    name: IdqA
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: IdqA
    description: 'DELTAMODE: The dq-axis current for phase A or triplex phase.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  IdqB:
    name: IdqB
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: IdqB
    description: 'DELTAMODE: The dq-axis current for phase B.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  IdqC:
    name: IdqC
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: IdqC
    description: 'DELTAMODE: The dq-axis current for phase C.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  Tfreq_delay:
    name: Tfreq_delay
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tfreq_delay
    description: 'DELTAMODE: The time constant for delayed frequency seen by the inverter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  inverter_droop_fp:
    name: inverter_droop_fp
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: inverter_droop_fp
    description: 'DELTAMODE: Boolean used to indicate whether inverter f/p droop is
      included or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  R_fp:
    name: R_fp
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_fp
    description: 'DELTAMODE: The droop parameter of the f/p droop'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  kppmax:
    name: kppmax
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kppmax
    description: 'DELTAMODE: The proportional gain of Pmax controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  kipmax:
    name: kipmax
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kipmax
    description: 'DELTAMODE: The integral gain of Pmax controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  Pmax:
    name: Pmax
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pmax
    description: 'DELTAMODE: power limit of grid forming inverter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  Pmin:
    name: Pmin
    annotations:
      order:
        tag: order
        value: 93
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pmin
    description: 'DELTAMODE: power limit of grid forming inverter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
  Pmax_Low_Limit:
    name: Pmax_Low_Limit
    annotations:
      order:
        tag: order
        value: 94
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Pmax_Low_Limit
    description: 'DELTAMODE: output limit of Pmax controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  Tvol_delay:
    name: Tvol_delay
    annotations:
      order:
        tag: order
        value: 95
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tvol_delay
    description: 'DELTAMODE: The time constant for delayed voltage seen by the inverter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  inverter_droop_vq:
    name: inverter_droop_vq
    annotations:
      order:
        tag: order
        value: 96
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: inverter_droop_vq
    description: 'DELTAMODE: Boolean used to indicate whether inverter q/v droop is
      included or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  R_vq:
    name: R_vq
    annotations:
      order:
        tag: order
        value: 97
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: R_vq
    description: 'DELTAMODE: The droop parameter of the v/q droop'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  Tp_delay:
    name: Tp_delay
    annotations:
      order:
        tag: order
        value: 98
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tp_delay
    description: 'DELTAMODE: The time constant for delayed real power seen by the
      VSI droop controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  Tq_delay:
    name: Tq_delay
    annotations:
      order:
        tag: order
        value: 99
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Tq_delay
    description: 'DELTAMODE: The time constant for delayed reactive power seen by
      the VSI droop controller'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  VSI_Rfilter:
    name: VSI_Rfilter
    annotations:
      order:
        tag: order
        value: 100
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: VSI_Rfilter[pu]
    description: VSI filter resistance (p.u.)
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: pu
  VSI_Xfilter:
    name: VSI_Xfilter
    annotations:
      order:
        tag: order
        value: 101
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: VSI_Xfilter[pu]
    description: VSI filter inductance (p.u.)
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
    unit:
      ucum_code: pu
  VSI_mode:
    name: VSI_mode
    annotations:
      order:
        tag: order
        value: 102
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: VSI_mode
    description: 'VSI MODEL: Selects VSI mode for either isochronous or droop one'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  VSI_freq:
    name: VSI_freq
    annotations:
      order:
        tag: order
        value: 103
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VSI_freq
    description: VSI frequency
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  ki_Vterminal:
    name: ki_Vterminal
    annotations:
      order:
        tag: order
        value: 104
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: ki_Vterminal
    description: 'DELTAMODE: The integrator gain for the VSI terminal voltage modulation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  kp_Vterminal:
    name: kp_Vterminal
    annotations:
      order:
        tag: order
        value: 105
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: kp_Vterminal
    description: 'DELTAMODE: The proportional gain for the VSI terminal voltage modulation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  V_set_droop:
    name: V_set_droop
    annotations:
      order:
        tag: order
        value: 106
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_set_droop
    description: 'DELTAMODE: The voltage setpoint of droop control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  V_set0:
    name: V_set0
    annotations:
      order:
        tag: order
        value: 107
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_set0
    description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  V_set1:
    name: V_set1
    annotations:
      order:
        tag: order
        value: 108
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_set1
    description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  V_set2:
    name: V_set2
    annotations:
      order:
        tag: order
        value: 109
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_set2
    description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  enable_ramp_rates_real:
    name: enable_ramp_rates_real
    annotations:
      order:
        tag: order
        value: 110
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: enable_ramp_rates_real
    description: 'DELTAMODE: Boolean used to indicate whether inverter ramp rate is
      enforced or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  max_ramp_up_real:
    name: max_ramp_up_real
    annotations:
      order:
        tag: order
        value: 111
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_ramp_up_real[W/s]
    description: 'DELTAMODE: The real power ramp up rate limit'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W/s
  max_ramp_down_real:
    name: max_ramp_down_real
    annotations:
      order:
        tag: order
        value: 112
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_ramp_down_real[W/s]
    description: 'DELTAMODE: The real power ramp down rate limit'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W/s
  enable_ramp_rates_reactive:
    name: enable_ramp_rates_reactive
    annotations:
      order:
        tag: order
        value: 113
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: enable_ramp_rates_reactive
    description: 'DELTAMODE: Boolean used to indicate whether inverter ramp rate is
      enforced or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  max_ramp_up_reactive:
    name: max_ramp_up_reactive
    annotations:
      order:
        tag: order
        value: 114
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_ramp_up_reactive[VAr/s]
    description: 'DELTAMODE: The reactive power ramp up rate limit'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: VAr/s
  max_ramp_down_reactive:
    name: max_ramp_down_reactive
    annotations:
      order:
        tag: order
        value: 115
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_ramp_down_reactive[VAr/s]
    description: 'DELTAMODE: The reactive power ramp down rate limit'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: VAr/s
  dynamic_model_mode:
    name: dynamic_model_mode
    annotations:
      order:
        tag: order
        value: 116
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: dynamic_model_mode
    description: 'DELTAMODE: Underlying model to use for deltamode control'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  enable_1547_checks:
    name: enable_1547_checks
    annotations:
      order:
        tag: order
        value: 117
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: enable_1547_checks
    description: 'DELTAMODE: Enable IEEE 1547-2003 disconnect checking'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: boolean
    required: false
  reconnect_time:
    name: reconnect_time
    annotations:
      order:
        tag: order
        value: 118
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: reconnect_time[s]
    description: 'DELTAMODE: Time delay after IEEE 1547-2003 violation clears before
      resuming generation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - motor
    - performance_motor
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  inverter_1547_status:
    name: inverter_1547_status
    annotations:
      order:
        tag: order
        value: 119
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: inverter_1547_status
    description: 'DELTAMODE: Indicator if the inverter is curtailed due to a 1547
      violation or not'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: boolean
    required: false
  IEEE_1547_version:
    name: IEEE_1547_version
    annotations:
      order:
        tag: order
        value: 120
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: IEEE_1547_version
    description: 'DELTAMODE: Version of IEEE 1547 to use to populate defaults'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: Ieee1547Version
    required: false
  over_freq_high_cutout:
    name: over_freq_high_cutout
    annotations:
      order:
        tag: order
        value: 121
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_high_cutout[Hz]
    description: 'DELTAMODE: OF2 set point for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: Hz
  over_freq_high_disconnect_time:
    name: over_freq_high_disconnect_time
    annotations:
      order:
        tag: order
        value: 122
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_high_disconnect_time[s]
    description: 'DELTAMODE: OF2 clearing time for IEEE1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  over_freq_low_cutout:
    name: over_freq_low_cutout
    annotations:
      order:
        tag: order
        value: 123
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_low_cutout[Hz]
    description: 'DELTAMODE: OF1 set point for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: Hz
  over_freq_low_disconnect_time:
    name: over_freq_low_disconnect_time
    annotations:
      order:
        tag: order
        value: 124
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_low_disconnect_time[s]
    description: 'DELTAMODE: OF1 clearing time for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_freq_high_cutout:
    name: under_freq_high_cutout
    annotations:
      order:
        tag: order
        value: 125
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_high_cutout[Hz]
    description: 'DELTAMODE: UF2 set point for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: Hz
  under_freq_high_disconnect_time:
    name: under_freq_high_disconnect_time
    annotations:
      order:
        tag: order
        value: 126
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_high_disconnect_time[s]
    description: 'DELTAMODE: UF2 clearing time for IEEE1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_freq_low_cutout:
    name: under_freq_low_cutout
    annotations:
      order:
        tag: order
        value: 127
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_low_cutout[Hz]
    description: 'DELTAMODE: UF1 set point for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: Hz
  under_freq_low_disconnect_time:
    name: under_freq_low_disconnect_time
    annotations:
      order:
        tag: order
        value: 128
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_low_disconnect_time[s]
    description: 'DELTAMODE: UF1 clearing time for IEEE 1547a'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_voltage_low_cutout:
    name: under_voltage_low_cutout
    annotations:
      order:
        tag: order
        value: 129
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_low_cutout[pu]
    description: Lowest voltage threshold for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  under_voltage_middle_cutout:
    name: under_voltage_middle_cutout
    annotations:
      order:
        tag: order
        value: 130
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_middle_cutout[pu]
    description: Middle-lowest voltage threshold for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  under_voltage_high_cutout:
    name: under_voltage_high_cutout
    annotations:
      order:
        tag: order
        value: 131
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_high_cutout[pu]
    description: High value of low voltage threshold for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  over_voltage_low_cutout:
    name: over_voltage_low_cutout
    annotations:
      order:
        tag: order
        value: 132
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_low_cutout[pu]
    description: Lowest voltage value for overvoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  over_voltage_high_cutout:
    name: over_voltage_high_cutout
    annotations:
      order:
        tag: order
        value: 133
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_high_cutout[pu]
    description: High voltage value for overvoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: pu
  under_voltage_low_disconnect_time:
    name: under_voltage_low_disconnect_time
    annotations:
      order:
        tag: order
        value: 134
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_low_disconnect_time[s]
    description: Lowest voltage clearing time for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_voltage_middle_disconnect_time:
    name: under_voltage_middle_disconnect_time
    annotations:
      order:
        tag: order
        value: 135
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_middle_disconnect_time[s]
    description: Middle-lowest voltage clearing time for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  under_voltage_high_disconnect_time:
    name: under_voltage_high_disconnect_time
    annotations:
      order:
        tag: order
        value: 136
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_high_disconnect_time[s]
    description: Highest voltage clearing time for undervoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  over_voltage_low_disconnect_time:
    name: over_voltage_low_disconnect_time
    annotations:
      order:
        tag: order
        value: 137
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_low_disconnect_time[s]
    description: Lowest voltage clearing time for overvoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  over_voltage_high_disconnect_time:
    name: over_voltage_high_disconnect_time
    annotations:
      order:
        tag: order
        value: 138
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_high_disconnect_time[s]
    description: Highest voltage clearing time for overvoltage
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: float
    required: false
    unit:
      ucum_code: s
  IEEE_1547_trip_method:
    name: IEEE_1547_trip_method
    annotations:
      order:
        tag: order
        value: 139
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: IEEE_1547_trip_method
    description: High over-voltage level trip
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - inverter_dyn
    range: Ieee1547TripMethod
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 140
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    description: The phases the inverter is attached to
    comments:
    - 'Import: A, B, C is wye to neutral (phases blank on three); S is s1s2 D across
      the legs at 240 V. Export: the letters then N; a split-phase bus''s letter then
      S.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    related_mappings:
    - cim:Terminal.phases
    - cim:PowerElectronicsConnection.phaseConnection
    owner: inverter
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  use_multipoint_efficiency:
    name: use_multipoint_efficiency
    annotations:
      order:
        tag: order
        value: 141
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: use_multipoint_efficiency
    description: 'FOUR QUADRANT MODEL: boolean to used the multipoint efficiency curve
      for the inverter when solar is attached'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  inverter_manufacturer:
    name: inverter_manufacturer
    annotations:
      order:
        tag: order
        value: 142
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inverter_manufacturer
    description: 'MULTIPOINT EFFICIENCY MODEL: the manufacturer of the inverter to
      setup up pre-existing efficiency curves'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  maximum_dc_power:
    name: maximum_dc_power
    annotations:
      order:
        tag: order
        value: 143
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_dc_power
    description: 'MULTIPOINT EFFICIENCY MODEL: the maximum dc power point for the
      efficiency curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  maximum_dc_voltage:
    name: maximum_dc_voltage
    annotations:
      order:
        tag: order
        value: 144
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_dc_voltage
    description: 'MULTIPOINT EFFICIENCY MODEL: the maximum dc voltage point for the
      efficiency curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  minimum_dc_power:
    name: minimum_dc_power
    annotations:
      order:
        tag: order
        value: 145
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: minimum_dc_power
    description: 'MULTIPOINT EFFICIENCY MODEL: the minimum dc power point for the
      efficiency curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  c_0:
    name: c_0
    annotations:
      order:
        tag: order
        value: 146
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: c_0
    description: 'MULTIPOINT EFFICIENCY MODEL: the first coefficient in the efficiency
      curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  c_1:
    name: c_1
    annotations:
      order:
        tag: order
        value: 147
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: c_1
    description: 'MULTIPOINT EFFICIENCY MODEL: the second coefficient in the efficiency
      curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  c_2:
    name: c_2
    annotations:
      order:
        tag: order
        value: 148
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: c_2
    description: 'MULTIPOINT EFFICIENCY MODEL: the third coefficient in the efficiency
      curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  c_3:
    name: c_3
    annotations:
      order:
        tag: order
        value: 149
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: c_3
    description: 'MULTIPOINT EFFICIENCY MODEL: the fourth coefficient in the efficiency
      curve'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  sense_object:
    name: sense_object
    annotations:
      order:
        tag: order
        value: 150
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: sense_object
    description: 'FOUR QUADRANT MODEL: name of the object the inverter is trying to
      mitigate the load on (node/link) in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  max_charge_rate:
    name: max_charge_rate
    annotations:
      order:
        tag: order
        value: 151
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_charge_rate[W]
    description: 'FOUR QUADRANT MODEL: maximum rate the battery can be charged in
      LOAD_FOLLOWING'
    comments:
    - 'Import: StorageInverterInfo.chargeRateActiveMax (W), a nameplate GridLAB-D
      reads only in load following. Export: chargeRateActiveMax x the unit''s share.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    exact_mappings:
    - cim:StorageInverterInfo.chargeRateActiveMax
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  max_discharge_rate:
    name: max_discharge_rate
    annotations:
      order:
        tag: order
        value: 152
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_discharge_rate[W]
    description: 'FOUR QUADRANT MODEL: maximum rate the battery can be discharged
      in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  charge_on_threshold:
    name: charge_on_threshold
    annotations:
      order:
        tag: order
        value: 153
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: charge_on_threshold[W]
    description: 'FOUR QUADRANT MODEL: power level at which the inverter should try
      charging the battery in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  charge_off_threshold:
    name: charge_off_threshold
    annotations:
      order:
        tag: order
        value: 154
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: charge_off_threshold[W]
    description: 'FOUR QUADRANT MODEL: power level at which the inverter should cease
      charging the battery in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  discharge_on_threshold:
    name: discharge_on_threshold
    annotations:
      order:
        tag: order
        value: 155
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: discharge_on_threshold[W]
    description: 'FOUR QUADRANT MODEL: power level at which the inverter should try
      discharging the battery in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  discharge_off_threshold:
    name: discharge_off_threshold
    annotations:
      order:
        tag: order
        value: 156
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: discharge_off_threshold[W]
    description: 'FOUR QUADRANT MODEL: power level at which the inverter should cease
      discharging the battery in LOAD_FOLLOWING'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  excess_input_power:
    name: excess_input_power
    annotations:
      order:
        tag: order
        value: 157
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: excess_input_power[W]
    description: 'FOUR QUADRANT MODEL: Excess power at the input of the inverter that
      is otherwise just lost, or could be shunted to a battery'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  charge_lockout_time:
    name: charge_lockout_time
    annotations:
      order:
        tag: order
        value: 158
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: charge_lockout_time[s]
    description: 'FOUR QUADRANT MODEL: Lockout time when a charging operation occurs
      before another LOAD_FOLLOWING dispatch operation can occur'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  discharge_lockout_time:
    name: discharge_lockout_time
    annotations:
      order:
        tag: order
        value: 159
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: discharge_lockout_time[s]
    description: 'FOUR QUADRANT MODEL: Lockout time when a discharging operation occurs
      before another LOAD_FOLLOWING dispatch operation can occur'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  pf_reg_activate:
    name: pf_reg_activate
    annotations:
      order:
        tag: order
        value: 160
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_activate
    description: 'FOUR QUADRANT MODEL: Lowest acceptable power-factor level below
      which power-factor regulation will activate.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_deactivate:
    name: pf_reg_deactivate
    annotations:
      order:
        tag: order
        value: 161
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_deactivate
    description: 'FOUR QUADRANT MODEL: Lowest acceptable power-factor above which
      no power-factor regulation is needed.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pf_target:
    name: pf_target
    annotations:
      order:
        tag: order
        value: 162
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_target
    description: 'FOUR QUADRANT MODEL: Desired power-factor to maintain (signed) positive
      is inductive'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_high:
    name: pf_reg_high
    annotations:
      order:
        tag: order
        value: 163
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_high
    description: 'FOUR QUADRANT MODEL: Upper limit for power-factor - if exceeds,
      go full reverse reactive'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_low:
    name: pf_reg_low
    annotations:
      order:
        tag: order
        value: 164
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_low
    description: 'FOUR QUADRANT MODEL: Lower limit for power-factor - if exceeds,
      stop regulating - pf_target_var is below this'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_activate_lockout_time:
    name: pf_reg_activate_lockout_time
    annotations:
      order:
        tag: order
        value: 165
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_activate_lockout_time[s]
    description: 'FOUR QUADRANT MODEL: Mandatory pause between the deactivation of
      power-factor regulation and it reactivation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  disable_volt_var_if_no_input_power:
    name: disable_volt_var_if_no_input_power
    annotations:
      order:
        tag: order
        value: 166
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: disable_volt_var_if_no_input_power
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  delay_time:
    name: delay_time
    annotations:
      order:
        tag: order
        value: 167
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: delay_time[s]
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  max_var_slew_rate:
    name: max_var_slew_rate
    annotations:
      order:
        tag: order
        value: 168
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_var_slew_rate[VAr/s]
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: VAr/s
  max_pwr_slew_rate:
    name: max_pwr_slew_rate
    annotations:
      order:
        tag: order
        value: 169
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: max_pwr_slew_rate[W/s]
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W/s
  volt_var_sched:
    name: volt_var_sched
    annotations:
      order:
        tag: order
        value: 170
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: volt_var_sched
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  freq_pwr_sched:
    name: freq_pwr_sched
    annotations:
      order:
        tag: order
        value: 171
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: freq_pwr_sched
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  charge_threshold:
    name: charge_threshold
    annotations:
      order:
        tag: order
        value: 172
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: charge_threshold[W]
    description: 'FOUR QUADRANT MODEL: Level at which all inverters in the group will
      begin charging attached batteries. Regulated minimum load level.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  discharge_threshold:
    name: discharge_threshold
    annotations:
      order:
        tag: order
        value: 173
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: discharge_threshold[W]
    description: 'FOUR QUADRANT MODEL: Level at which all inverters in the group will
      begin discharging attached batteries. Regulated maximum load level.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  group_max_charge_rate:
    name: group_max_charge_rate
    annotations:
      order:
        tag: order
        value: 174
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: group_max_charge_rate[W]
    description: 'FOUR QUADRANT MODEL: Sum of the charge rates of the batteries involved
      in the group load-following.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  group_max_discharge_rate:
    name: group_max_discharge_rate
    annotations:
      order:
        tag: order
        value: 175
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: group_max_discharge_rate[W]
    description: 'FOUR QUADRANT MODEL: Sum of the discharge rates of the batteries
      involved in the group load-following.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  group_rated_power:
    name: group_rated_power
    annotations:
      order:
        tag: order
        value: 176
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: group_rated_power[W]
    description: 'FOUR QUADRANT MODEL: Sum of the inverter power ratings of the inverters
      involved in the group power-factor regulation.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: W
  V_base:
    name: V_base
    annotations:
      order:
        tag: order
        value: 177
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V_base[V]
    description: 'FOUR QUADRANT MODEL: The base voltage on the grid side of the inverter.
      Used in VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: V
  V1:
    name: V1
    annotations:
      order:
        tag: order
        value: 178
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V1[pu]
    description: 'FOUR QUADRANT MODEL: voltage point 1 in volt/var curve. Used in
      VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  Q1:
    name: Q1
    annotations:
      order:
        tag: order
        value: 179
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q1[pu]
    description: 'FOUR QUADRANT MODEL: VAR point 1 in volt/var curve. Used in VOLT_VAR
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  V2:
    name: V2
    annotations:
      order:
        tag: order
        value: 180
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V2[pu]
    description: 'FOUR QUADRANT MODEL: voltage point 2 in volt/var curve. Used in
      VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  Q2:
    name: Q2
    annotations:
      order:
        tag: order
        value: 181
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q2[pu]
    description: 'FOUR QUADRANT MODEL: VAR point 2 in volt/var curve. Used in VOLT_VAR
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  V3:
    name: V3
    annotations:
      order:
        tag: order
        value: 182
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V3[pu]
    description: 'FOUR QUADRANT MODEL: voltage point 3 in volt/var curve. Used in
      VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  Q3:
    name: Q3
    annotations:
      order:
        tag: order
        value: 183
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q3[pu]
    description: 'FOUR QUADRANT MODEL: VAR point 3 in volt/var curve. Used in VOLT_VAR
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  V4:
    name: V4
    annotations:
      order:
        tag: order
        value: 184
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: V4[pu]
    description: 'FOUR QUADRANT MODEL: voltage point 4 in volt/var curve. Used in
      VOLT_VAR control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  Q4:
    name: Q4
    annotations:
      order:
        tag: order
        value: 185
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: Q4[pu]
    description: 'FOUR QUADRANT MODEL: VAR point 4 in volt/var curve. Used in VOLT_VAR
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  volt_var_control_lockout:
    name: volt_var_control_lockout
    annotations:
      order:
        tag: order
        value: 186
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: volt_var_control_lockout[s]
    description: 'FOUR QUADRANT QUADRANT MODEL: the lockout time between volt/var
      actions.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: s
  number_of_phases_out:
    name: number_of_phases_out
    annotations:
      order:
        tag: order
        value: 187
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: number_of_phases_out
    description: Exposed variable - hidden for solar
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: integer
    required: false
  efficiency_value:
    name: efficiency_value
    annotations:
      order:
        tag: order
        value: 188
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: efficiency_value
    description: Exposed variable - hidden for solar
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  VW_V1:
    name: VW_V1
    annotations:
      order:
        tag: order
        value: 189
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VW_V1[pu]
    description: 'FOUR QUADRANT MODEL: Voltage at which power limiting begins (e.g.
      1.0583). Used in VOLT_WATT control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  VW_V2:
    name: VW_V2
    annotations:
      order:
        tag: order
        value: 190
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VW_V2[pu]
    description: 'FOUR QUADRANT MODEL: Voltage at which power limiting ends. (e.g.
      1.1000). Used in VOLT_WATT control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  VW_P1:
    name: VW_P1
    annotations:
      order:
        tag: order
        value: 191
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VW_P1[pu]
    description: 'FOUR QUADRANT MODEL: Power limit at VW_P1 (e.g. 1). Used in VOLT_WATT
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  VW_P2:
    name: VW_P2
    annotations:
      order:
        tag: order
        value: 192
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: VW_P2[pu]
    description: 'FOUR QUADRANT MODEL: Power limit at VW_P2 (e.g. 0). Used in VOLT_WATT
      control mode.'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
    unit:
      ucum_code: pu
  WT_is_connected:
    name: WT_is_connected
    annotations:
      order:
        tag: order
        value: 193
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: WT_is_connected
    description: Internal flag that indicates a wind turbine child is connected
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  pf_reg_status:
    name: pf_reg_status
    annotations:
      order:
        tag: order
        value: 194
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: pf_reg_status
    description: 'CHECKPOINT_VAR: internal variable for pf_reg_status'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  load_follow_status:
    name: load_follow_status
    annotations:
      order:
        tag: order
        value: 195
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: load_follow_status
    description: 'CHECKPOINT_VAR: Status variable for what the load_following mode
      is doing'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  last_current_A:
    name: last_current_A
    annotations:
      order:
        tag: order
        value: 196
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_current_A
    description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
      from parent so XML files look proper) - element 0'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_current_B:
    name: last_current_B
    annotations:
      order:
        tag: order
        value: 197
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_current_B
    description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
      from parent so XML files look proper) - element 1'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_current_C:
    name: last_current_C
    annotations:
      order:
        tag: order
        value: 198
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_current_C
    description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
      from parent so XML files look proper) - element 2'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_current_D:
    name: last_current_D
    annotations:
      order:
        tag: order
        value: 199
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_current_D
    description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
      from parent so XML files look proper) - element 3'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_power_A:
    name: last_power_A
    annotations:
      order:
        tag: order
        value: 200
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_power_A
    description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
      - used to remove from parent so XML looks right - element 0'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_power_B:
    name: last_power_B
    annotations:
      order:
        tag: order
        value: 201
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_power_B
    description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
      - used to remove from parent so XML looks right - element 1'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_power_C:
    name: last_power_C
    annotations:
      order:
        tag: order
        value: 202
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_power_C
    description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
      - used to remove from parent so XML looks right - element 2'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_power_D:
    name: last_power_D
    annotations:
      order:
        tag: order
        value: 203
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_power_D
    description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
      - used to remove from parent so XML looks right - element 3'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  inverter_first_step:
    name: inverter_first_step
    annotations:
      order:
        tag: order
        value: 204
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: inverter_first_step
    description: 'CHECKPOINT_VAR: internal variable for inverter_first_step'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  first_iteration_current_injection:
    name: first_iteration_current_injection
    annotations:
      order:
        tag: order
        value: 205
      value_type:
        tag: value_type
        value: int
      native_name:
        tag: native_name
        value: first_iteration_current_injection
    description: 'CHECKPOINT_VAR: Initialization variable - mostly so SWING_PQ buses
      initalize properly for deltamode'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: integer
    required: false
  m12:
    name: m12
    annotations:
      order:
        tag: order
        value: 206
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: m12
    description: 'CHECKPOINT_VAR: internal variable for m12'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  b12:
    name: b12
    annotations:
      order:
        tag: order
        value: 207
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b12
    description: 'CHECKPOINT_VAR: internal variable for b12'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  m23:
    name: m23
    annotations:
      order:
        tag: order
        value: 208
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: m23
    description: 'CHECKPOINT_VAR: internal variable for m23'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  b23:
    name: b23
    annotations:
      order:
        tag: order
        value: 209
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b23
    description: 'CHECKPOINT_VAR: internal variable for b23'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  m34:
    name: m34
    annotations:
      order:
        tag: order
        value: 210
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: m34
    description: 'CHECKPOINT_VAR: internal variable for m34'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  b34:
    name: b34
    annotations:
      order:
        tag: order
        value: 211
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: b34
    description: 'CHECKPOINT_VAR: internal variable for b34'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  allowed_vv_action:
    name: allowed_vv_action
    annotations:
      order:
        tag: order
        value: 212
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: allowed_vv_action
    description: 'CHECKPOINT_VAR: internal variable for allowed_vv_action'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  last_vv_check:
    name: last_vv_check
    annotations:
      order:
        tag: order
        value: 213
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: last_vv_check
    description: 'CHECKPOINT_VAR: internal variable for last_vv_check'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  IEEE_1547_STATUS:
    name: IEEE_1547_STATUS
    annotations:
      order:
        tag: order
        value: 214
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: IEEE_1547_STATUS
    description: 'CHECKPOINT_VAR: internal variable for ieee_1547_version'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  over_freq_high_band_viol_time:
    name: over_freq_high_band_viol_time
    annotations:
      order:
        tag: order
        value: 215
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_high_band_viol_time
    description: 'CHECKPOINT_VAR: OF2 violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  over_freq_low_band_viol_time:
    name: over_freq_low_band_viol_time
    annotations:
      order:
        tag: order
        value: 216
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_freq_low_band_viol_time
    description: 'CHECKPOINT_VAR: OF1 violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  under_freq_low_band_viol_time:
    name: under_freq_low_band_viol_time
    annotations:
      order:
        tag: order
        value: 217
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_freq_low_band_viol_time
    description: 'CHECKPOINT_VAR: UF1 violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  under_voltage_lowest_viol_time:
    name: under_voltage_lowest_viol_time
    annotations:
      order:
        tag: order
        value: 218
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_lowest_viol_time
    description: 'CHECKPOINT_VAR: Lowest low voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  under_voltage_middle_viol_time:
    name: under_voltage_middle_viol_time
    annotations:
      order:
        tag: order
        value: 219
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_middle_viol_time
    description: 'CHECKPOINT_VAR: Middle low voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  under_voltage_high_viol_time:
    name: under_voltage_high_viol_time
    annotations:
      order:
        tag: order
        value: 220
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: under_voltage_high_viol_time
    description: 'CHECKPOINT_VAR: Highest low voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  over_voltage_low_viol_time:
    name: over_voltage_low_viol_time
    annotations:
      order:
        tag: order
        value: 221
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_low_viol_time
    description: 'CHECKPOINT_VAR: Lowest high voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  over_voltage_high_viol_time:
    name: over_voltage_high_viol_time
    annotations:
      order:
        tag: order
        value: 222
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: over_voltage_high_viol_time
    description: 'CHECKPOINT_VAR: Highest high voltage threshold violation accumulator'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  lf_dispatch_power:
    name: lf_dispatch_power
    annotations:
      order:
        tag: order
        value: 223
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: lf_dispatch_power
    description: 'CHECKPOINT_VAR: Amount of real power to try and dispatch to meet
      thresholds'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  next_update_time:
    name: next_update_time
    annotations:
      order:
        tag: order
        value: 224
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: next_update_time
    description: 'CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  lf_dispatch_change_allowed:
    name: lf_dispatch_change_allowed
    annotations:
      order:
        tag: order
        value: 225
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: lf_dispatch_change_allowed
    description: 'CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  pf_reg_dispatch_change_allowed:
    name: pf_reg_dispatch_change_allowed
    annotations:
      order:
        tag: order
        value: 226
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: pf_reg_dispatch_change_allowed
    description: 'CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed
      for power factor regulation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  pf_reg_dispatch_VAR:
    name: pf_reg_dispatch_VAR
    annotations:
      order:
        tag: order
        value: 227
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pf_reg_dispatch_VAR
    description: 'CHECKPOINT_VAR: (Reactive only?) power dispatched to meet power
      factor regulation threshold'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pf_reg_next_update_time:
    name: pf_reg_next_update_time
    annotations:
      order:
        tag: order
        value: 228
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: pf_reg_next_update_time
    description: 'CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  prev_time:
    name: prev_time
    annotations:
      order:
        tag: order
        value: 229
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: prev_time
    description: 'CHECKPOINT_VAR: Tracking variable for previous "new time" run'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - battery
    - inverter
    range: string
    required: false
  prev_time_dbl:
    name: prev_time_dbl
    annotations:
      order:
        tag: order
        value: 230
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: prev_time_dbl
    description: 'CHECKPOINT_VAR: Tracking variable for 1547 checks and ramp rates'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - evcharger_det
    range: float
    required: false
  event_deltat:
    name: event_deltat
    annotations:
      order:
        tag: order
        value: 231
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: event_deltat
    description: 'CHECKPOINT_VAR: Event-driven delta-t variable'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  start_time:
    name: start_time
    annotations:
      order:
        tag: order
        value: 232
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: start_time
    description: 'CHECKPOINT_VAR: Recording start time of simulation'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    - dryer
    - refrigerator
    range: string
    required: false
  last_I_Out_A:
    name: last_I_Out_A
    annotations:
      order:
        tag: order
        value: 233
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_I_Out_A
    description: 'CHECKPOINT_VAR: internal variable for last_I_Out[0]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_I_Out_B:
    name: last_I_Out_B
    annotations:
      order:
        tag: order
        value: 234
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_I_Out_B
    description: 'CHECKPOINT_VAR: internal variable for last_I_Out[1]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_I_Out_C:
    name: last_I_Out_C
    annotations:
      order:
        tag: order
        value: 235
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: last_I_Out_C
    description: 'CHECKPOINT_VAR: internal variable for last_I_Out[2]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  last_I_In:
    name: last_I_In
    annotations:
      order:
        tag: order
        value: 236
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: last_I_In
    description: 'CHECKPOINT_VAR: internal variable for last_I_In'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pa_vw_limited:
    name: pa_vw_limited
    annotations:
      order:
        tag: order
        value: 237
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pa_vw_limited
    description: 'CHECKPOINT_VAR: internal variable for pa_vw_limited'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pb_vw_limited:
    name: pb_vw_limited
    annotations:
      order:
        tag: order
        value: 238
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pb_vw_limited
    description: 'CHECKPOINT_VAR: internal variable for pb_vw_limited'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  pc_vw_limited:
    name: pc_vw_limited
    annotations:
      order:
        tag: order
        value: 239
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pc_vw_limited
    description: 'CHECKPOINT_VAR: internal variable for pc_vw_limited'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  out_of_violation_time_total:
    name: out_of_violation_time_total
    annotations:
      order:
        tag: order
        value: 240
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: out_of_violation_time_total
    description: 'CHECKPOINT_VAR: internal variable for out_of_violation_time_total'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: float
    required: false
  deltamode_inclusive:
    name: deltamode_inclusive
    annotations:
      order:
        tag: order
        value: 241
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: deltamode_inclusive
    description: 'CHECKPOINT_VAR: Boolean for deltamode calls - pulled from object
      flags'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  first_sync_delta_enabled:
    name: first_sync_delta_enabled
    annotations:
      order:
        tag: order
        value: 242
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: first_sync_delta_enabled
    description: 'CHECKPOINT_VAR: internal variable for first_sync_delta_enabled'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: boolean
    required: false
  first_iter_counter:
    name: first_iter_counter
    annotations:
      order:
        tag: order
        value: 243
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: first_iter_counter
    description: 'CHECKPOINT_VAR: internal variable for first_iter_counter'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: string
    required: false
  first_run:
    name: first_run
    annotations:
      order:
        tag: order
        value: 244
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: first_run
    description: 'CHECKPOINT_VAR: internal variable for first_run'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    owner: inverter
    domain_of:
    - controller_dg
    - inverter
    range: boolean
    required: false
  prev_value_IGenerated_A:
    name: prev_value_IGenerated_A
    annotations:
      order:
        tag: order
        value: 245
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_value_IGenerated_A
    description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[0]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  prev_value_IGenerated_B:
    name: prev_value_IGenerated_B
    annotations:
      order:
        tag: order
        value: 246
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_value_IGenerated_B
    description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[1]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  prev_value_IGenerated_C:
    name: prev_value_IGenerated_C
    annotations:
      order:
        tag: order
        value: 247
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prev_value_IGenerated_C
    description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[2]'
    from_schema: https://gridlabd.org/schema/glm/generators/inverter
    rank: 1000
    owner: inverter
    domain_of:
    - inverter
    range: Complex
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: inverter
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: inverter
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: inverter
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: inverter
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: inverter
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: inverter
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: inverter
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: inverter
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: inverter
    domain_of:
    - glm_object
    range: string