Class: Inverter¶
Copyright (C) 2008 Battelle Memorial Institute
@file inverter.cpp
@defgroup inverter
@ingroup generators
@{
__
Inherits from: gld_object
__
Type: Instance (network topology element)
__
Note: Inherits from gld_object (not in generators module)
URI: glm:Inverter
classDiagram
class Inverter
click Inverter href "../Inverter/"
GlmObject <|-- Inverter
click GlmObject href "../GlmObject/"
Inverter : allowed_vv_action
Inverter : b12
Inverter : b23
Inverter : b34
Inverter : battery_soc
Inverter : c_0
Inverter : c_1
Inverter : c_2
Inverter : c_3
Inverter : charge_lockout_time
Inverter : charge_off_threshold
Inverter : charge_on_threshold
Inverter : charge_threshold
Inverter : curr_VA_out_A
Inverter --> "0..1" Complex : curr_VA_out_A
click Complex href "../Complex/"
Inverter : curr_VA_out_B
Inverter --> "0..1" Complex : curr_VA_out_B
click Complex href "../Complex/"
Inverter : curr_VA_out_C
Inverter --> "0..1" Complex : curr_VA_out_C
click Complex href "../Complex/"
Inverter : current_convergence
Inverter : delay_time
Inverter : delta_epA
Inverter : delta_epB
Inverter : delta_epC
Inverter : delta_eqA
Inverter : delta_eqB
Inverter : delta_eqC
Inverter : delta_mdA
Inverter : delta_mdB
Inverter : delta_mdC
Inverter : delta_mqA
Inverter : delta_mqB
Inverter : delta_mqC
Inverter : deltamode_inclusive
Inverter : disable_volt_var_if_no_input_power
Inverter : discharge_lockout_time
Inverter : discharge_off_threshold
Inverter : discharge_on_threshold
Inverter : discharge_threshold
Inverter : dynamic_model_mode
Inverter : e_source_A
Inverter : e_source_B
Inverter : e_source_C
Inverter : efficiency_value
Inverter : enable_1547_checks
Inverter : enable_ramp_rates_reactive
Inverter : enable_ramp_rates_real
Inverter : epA
Inverter : epB
Inverter : epC
Inverter : eqA
Inverter : eqB
Inverter : eqC
Inverter : event_deltat
Inverter : excess_input_power
Inverter : first_iter_counter
Inverter : first_iteration_current_injection
Inverter : first_run
Inverter : first_sync_delta_enabled
Inverter : flags
Inverter : four_quadrant_control_mode
Inverter : freq_pwr_sched
Inverter : generator_mode
Inverter --> "0..1" GeneratorMode : generator_mode
click GeneratorMode href "../GeneratorMode/"
Inverter : generator_status
Inverter : group_max_charge_rate
Inverter : group_max_discharge_rate
Inverter : group_rated_power
Inverter : groupid
Inverter : I_In
Inverter : IdqA
Inverter --> "0..1" Complex : IdqA
click Complex href "../Complex/"
Inverter : IdqB
Inverter --> "0..1" Complex : IdqB
click Complex href "../Complex/"
Inverter : IdqC
Inverter --> "0..1" Complex : IdqC
click Complex href "../Complex/"
Inverter : IEEE_1547_STATUS
Inverter : IEEE_1547_trip_method
Inverter --> "0..1" Ieee1547TripMethod : IEEE_1547_trip_method
click Ieee1547TripMethod href "../Ieee1547TripMethod/"
Inverter : IEEE_1547_version
Inverter --> "0..1" Ieee1547Version : IEEE_1547_version
click Ieee1547Version href "../Ieee1547Version/"
Inverter : in_svc
Inverter : inverter_1547_status
Inverter : inverter_convergence_criterion
Inverter : inverter_droop_fp
Inverter : inverter_droop_vq
Inverter : inverter_efficiency
Inverter : inverter_first_step
Inverter : inverter_manufacturer
Inverter : inverter_type
Inverter : islanded_state
Inverter : kdd
Inverter : kdq
Inverter : ki_Vterminal
Inverter : kid
Inverter : kipmax
Inverter : kiq
Inverter : kp_Vterminal
Inverter : kpd
Inverter : kppmax
Inverter : kpq
Inverter : last_current_A
Inverter --> "0..1" Complex : last_current_A
click Complex href "../Complex/"
Inverter : last_current_B
Inverter --> "0..1" Complex : last_current_B
click Complex href "../Complex/"
Inverter : last_current_C
Inverter --> "0..1" Complex : last_current_C
click Complex href "../Complex/"
Inverter : last_current_D
Inverter --> "0..1" Complex : last_current_D
click Complex href "../Complex/"
Inverter : last_I_In
Inverter : last_I_Out_A
Inverter --> "0..1" Complex : last_I_Out_A
click Complex href "../Complex/"
Inverter : last_I_Out_B
Inverter --> "0..1" Complex : last_I_Out_B
click Complex href "../Complex/"
Inverter : last_I_Out_C
Inverter --> "0..1" Complex : last_I_Out_C
click Complex href "../Complex/"
Inverter : last_power_A
Inverter --> "0..1" Complex : last_power_A
click Complex href "../Complex/"
Inverter : last_power_B
Inverter --> "0..1" Complex : last_power_B
click Complex href "../Complex/"
Inverter : last_power_C
Inverter --> "0..1" Complex : last_power_C
click Complex href "../Complex/"
Inverter : last_power_D
Inverter --> "0..1" Complex : last_power_D
click Complex href "../Complex/"
Inverter : last_vv_check
Inverter : latitude
Inverter : lf_dispatch_change_allowed
Inverter : lf_dispatch_power
Inverter : load_follow_status
Inverter : longitude
Inverter : m12
Inverter : m23
Inverter : m34
Inverter : max_charge_rate
Inverter : max_discharge_rate
Inverter : max_pwr_slew_rate
Inverter : max_ramp_down_reactive
Inverter : max_ramp_down_real
Inverter : max_ramp_up_reactive
Inverter : max_ramp_up_real
Inverter : max_var_slew_rate
Inverter : maximum_dc_power
Inverter : maximum_dc_voltage
Inverter : mdA
Inverter : mdB
Inverter : mdC
Inverter : minimum_dc_power
Inverter : mqA
Inverter : mqB
Inverter : mqC
Inverter : name
Inverter : next_update_time
Inverter : nominal_frequency
Inverter : number_of_phases_out
Inverter : out_of_violation_time_total
Inverter : out_svc
Inverter : over_freq_high_band_viol_time
Inverter : over_freq_high_cutout
Inverter : over_freq_high_disconnect_time
Inverter : over_freq_low_band_viol_time
Inverter : over_freq_low_cutout
Inverter : over_freq_low_disconnect_time
Inverter : over_voltage_high_cutout
Inverter : over_voltage_high_disconnect_time
Inverter : over_voltage_high_viol_time
Inverter : over_voltage_low_cutout
Inverter : over_voltage_low_disconnect_time
Inverter : over_voltage_low_viol_time
Inverter : P_In
Inverter : P_Out
Inverter : pa_vw_limited
Inverter : parent
Inverter : pb_vw_limited
Inverter : pc_vw_limited
Inverter : pCircuit_V_Avg
Inverter : pf_reg
Inverter : pf_reg_activate
Inverter : pf_reg_activate_lockout_time
Inverter : pf_reg_deactivate
Inverter : pf_reg_dispatch_change_allowed
Inverter : pf_reg_dispatch_VAR
Inverter : pf_reg_high
Inverter : pf_reg_low
Inverter : pf_reg_next_update_time
Inverter : pf_reg_status
Inverter : pf_target
Inverter : phaseA_I_Following
Inverter --> "0..1" Complex : phaseA_I_Following
click Complex href "../Complex/"
Inverter : phaseA_I_Forming
Inverter --> "0..1" Complex : phaseA_I_Forming
click Complex href "../Complex/"
Inverter : phaseA_I_Out
Inverter --> "0..1" Complex : phaseA_I_Out
click Complex href "../Complex/"
Inverter : phaseA_V_Out
Inverter --> "0..1" Complex : phaseA_V_Out
click Complex href "../Complex/"
Inverter : phaseB_I_Following
Inverter --> "0..1" Complex : phaseB_I_Following
click Complex href "../Complex/"
Inverter : phaseB_I_Forming
Inverter --> "0..1" Complex : phaseB_I_Forming
click Complex href "../Complex/"
Inverter : phaseB_I_Out
Inverter --> "0..1" Complex : phaseB_I_Out
click Complex href "../Complex/"
Inverter : phaseB_V_Out
Inverter --> "0..1" Complex : phaseB_V_Out
click Complex href "../Complex/"
Inverter : phaseC_I_Following
Inverter --> "0..1" Complex : phaseC_I_Following
click Complex href "../Complex/"
Inverter : phaseC_I_Forming
Inverter --> "0..1" Complex : phaseC_I_Forming
click Complex href "../Complex/"
Inverter : phaseC_I_Out
Inverter --> "0..1" Complex : phaseC_I_Out
click Complex href "../Complex/"
Inverter : phaseC_V_Out
Inverter --> "0..1" Complex : phaseC_V_Out
click Complex href "../Complex/"
Inverter : phases
Inverter : Pmax
Inverter : Pmax_Low_Limit
Inverter : Pmin
Inverter : power_A
Inverter --> "0..1" Complex : power_A
click Complex href "../Complex/"
Inverter : power_B
Inverter --> "0..1" Complex : power_B
click Complex href "../Complex/"
Inverter : power_C
Inverter --> "0..1" Complex : power_C
click Complex href "../Complex/"
Inverter : power_factor
Inverter : power_in
Inverter : Pref
Inverter : prev_time
Inverter : prev_time_dbl
Inverter : prev_VA_out_A
Inverter --> "0..1" Complex : prev_VA_out_A
click Complex href "../Complex/"
Inverter : prev_VA_out_B
Inverter --> "0..1" Complex : prev_VA_out_B
click Complex href "../Complex/"
Inverter : prev_VA_out_C
Inverter --> "0..1" Complex : prev_VA_out_C
click Complex href "../Complex/"
Inverter : prev_value_IGenerated_A
Inverter --> "0..1" Complex : prev_value_IGenerated_A
click Complex href "../Complex/"
Inverter : prev_value_IGenerated_B
Inverter --> "0..1" Complex : prev_value_IGenerated_B
click Complex href "../Complex/"
Inverter : prev_value_IGenerated_C
Inverter --> "0..1" Complex : prev_value_IGenerated_C
click Complex href "../Complex/"
Inverter : Q1
Inverter : Q2
Inverter : Q3
Inverter : Q4
Inverter : Q_Out
Inverter : Qref
Inverter : R_fp
Inverter : R_vq
Inverter : rank
Inverter : rated_battery_power
Inverter : rated_power
Inverter : reconnect_time
Inverter : sense_object
Inverter : soc_reserve
Inverter : start_time
Inverter : Tfreq_delay
Inverter : Tp_delay
Inverter : Tq_delay
Inverter : Tvol_delay
Inverter : under_freq_high_cutout
Inverter : under_freq_high_disconnect_time
Inverter : under_freq_low_band_viol_time
Inverter : under_freq_low_cutout
Inverter : under_freq_low_disconnect_time
Inverter : under_voltage_high_cutout
Inverter : under_voltage_high_disconnect_time
Inverter : under_voltage_high_viol_time
Inverter : under_voltage_low_cutout
Inverter : under_voltage_low_disconnect_time
Inverter : under_voltage_lowest_viol_time
Inverter : under_voltage_middle_cutout
Inverter : under_voltage_middle_disconnect_time
Inverter : under_voltage_middle_viol_time
Inverter : use_multipoint_efficiency
Inverter : V1
Inverter : V2
Inverter : V3
Inverter : V4
Inverter : V_angle_A
Inverter : V_angle_B
Inverter : V_angle_C
Inverter : V_base
Inverter : V_In
Inverter : V_set0
Inverter : V_set1
Inverter : V_set2
Inverter : V_set_droop
Inverter : VA_Out
Inverter --> "0..1" Complex : VA_Out
click Complex href "../Complex/"
Inverter : Vdc
Inverter : volt_var_control_lockout
Inverter : volt_var_sched
Inverter : VSI_freq
Inverter : VSI_mode
Inverter : VSI_Rfilter
Inverter --> "0..1" Complex : VSI_Rfilter
click Complex href "../Complex/"
Inverter : VSI_Xfilter
Inverter --> "0..1" Complex : VSI_Xfilter
click Complex href "../Complex/"
Inverter : VW_P1
Inverter : VW_P2
Inverter : VW_V1
Inverter : VW_V2
Inverter : WT_is_connected
Inheritance¶
- GlmObject
- Inverter
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| inverter_type | 0..1 String |
LEGACY MODEL: Sets efficiencies and other parameters; if using four_quadrant_... | direct |
| four_quadrant_control_mode | 0..1 String |
FOUR QUADRANT MODEL: Activates various control modes | direct |
| pf_reg | 0..1 String |
Activate (or not) power factor regulation in four_quadrant_control_mode | direct |
| generator_status | 0..1 String |
describes whether the generator is online or offline | direct |
| generator_mode | 0..1 GeneratorMode |
LEGACY MODEL: Selects generator control mode when using legacy model; in non-... | direct |
| inverter_convergence_criterion | 0..1 Float |
The maximum change in error threshold for exitting deltamode | direct |
| current_convergence | 0..1 Float |
Convergence criterion for current changes on first timestep - basically initi... | direct |
| V_In | 0..1 Float |
DC voltage | direct |
| I_In | 0..1 Float |
DC current | direct |
| P_In | 0..1 Float |
DC power | direct |
| VA_Out | 0..1 Complex |
AC power | direct |
| Vdc | 0..1 Float |
LEGACY MODEL: DC voltage | direct |
| phaseA_V_Out | 0..1 Complex |
AC voltage on A phase in three-phase system; 240-V connection on a triplex sy... | direct |
| phaseB_V_Out | 0..1 Complex |
AC voltage on B phase in three-phase system | direct |
| phaseC_V_Out | 0..1 Complex |
AC voltage on C phase in three-phase system | direct |
| phaseA_I_Out | 0..1 Complex |
AC current on A phase in three-phase system; 240-V connection on a triplex sy... | direct |
| phaseB_I_Out | 0..1 Complex |
AC current on B phase in three-phase system | direct |
| phaseC_I_Out | 0..1 Complex |
AC current on C phase in three-phase system | direct |
| power_A | 0..1 Complex |
AC power on A phase in three-phase system; 240-V connection on a triplex syst... | direct |
| power_B | 0..1 Complex |
AC power on B phase in three-phase system | direct |
| power_C | 0..1 Complex |
AC power on C phase in three-phase system | direct |
| curr_VA_out_A | 0..1 Complex |
AC power on A phase in three-phase system; 240-V connection on a triplex syst... | direct |
| curr_VA_out_B | 0..1 Complex |
AC power on B phase in three-phase system | direct |
| curr_VA_out_C | 0..1 Complex |
AC power on C phase in three-phase system | direct |
| prev_VA_out_A | 0..1 Complex |
AC power on A phase in three-phase system; 240-V connection on a triplex syst... | direct |
| prev_VA_out_B | 0..1 Complex |
AC power on B phase in three-phase system | direct |
| prev_VA_out_C | 0..1 Complex |
AC power on C phase in three-phase system | direct |
| e_source_A | 0..1 Float |
DELTAMODE: Internal voltage of grid-forming source, phase A | direct |
| e_source_B | 0..1 Float |
DELTAMODE: Internal voltage of grid-forming source, phase B | direct |
| e_source_C | 0..1 Float |
DELTAMODE: Internal voltage of grid-forming source, phase C | direct |
| V_angle_A | 0..1 Float |
DELTAMODE: Internal angle of grid-forming source, phase A | direct |
| V_angle_B | 0..1 Float |
DELTAMODE: Internal angle of grid-forming source, phase B | direct |
| V_angle_C | 0..1 Float |
DELTAMODE: Internal angle of grid-forming source, phase C | direct |
| phaseA_I_Forming | 0..1 Complex |
AC current on A phase in three-phase system, only for grid_forming | direct |
| phaseB_I_Forming | 0..1 Complex |
AC current on B phase in three-phase system, only for grid_forming | direct |
| phaseC_I_Forming | 0..1 Complex |
AC current on C phase in three-phase system, only for grid_forming | direct |
| phaseA_I_Following | 0..1 Complex |
AC current on A phase in three-phase system, only for grid_following | direct |
| phaseB_I_Following | 0..1 Complex |
AC current on B phase in three-phase system, only for grid_following | direct |
| phaseC_I_Following | 0..1 Complex |
AC current on C phase in three-phase system, only for grid_following | direct |
| pCircuit_V_Avg | 0..1 Float |
DELTAMODE: three-phase average value of terminal voltage | direct |
| P_Out | 0..1 Float |
FOUR QUADRANT MODEL: Scheduled real power out in CONSTANT_PQ control mode | direct |
| Q_Out | 0..1 Float |
FOUR QUADRANT MODEL: Schedule reactive power out in CONSTANT_PQ control mode | direct |
| power_in | 0..1 Float |
LEGACY MODEL: No longer used | direct |
| rated_power | 0..1 Float |
FOUR QUADRANT MODEL: The rated power of the inverter | direct |
| rated_battery_power | 0..1 Float |
FOUR QUADRANT MODEL: The rated power of battery when battery is attached | direct |
| inverter_efficiency | 0..1 Float |
FOUR QUADRANT MODEL: The efficiency of the inverter | direct |
| battery_soc | 0..1 Float |
FOUR QUADRANT MODEL: The state of charge of an attached battery | direct |
| soc_reserve | 0..1 Float |
FOUR QUADRANT MODEL: The reserve state of charge of an attached battery for i... | direct |
| power_factor | 0..1 Float |
FOUR QUADRANT MODEL: The power factor used for CONSTANT_PF control mode | direct |
| islanded_state | 0..1 Boolean |
FOUR QUADRANT MODEL: Boolean used to let control modes to act under island co... | direct |
| nominal_frequency | 0..1 Float |
direct | |
| Pref | 0..1 Float |
DELTAMODE: The real power reference | direct |
| Qref | 0..1 Float |
DELTAMODE: The reactive power reference | direct |
| kpd | 0..1 Float |
DELTAMODE: The d-axis integration gain for the current modulation PI controll... | direct |
| kpq | 0..1 Float |
DELTAMODE: The q-axis integration gain for the current modulation PI controll... | direct |
| kid | 0..1 Float |
DELTAMODE: The d-axis proportional gain for the current modulation PI control... | direct |
| kiq | 0..1 Float |
DELTAMODE: The q-axis proportional gain for the current modulation PI control... | direct |
| kdd | 0..1 Float |
DELTAMODE: The d-axis differentiator gain for the current modulation PID cont... | direct |
| kdq | 0..1 Float |
DELTAMODE: The q-axis differentiator gain for the current modulation PID cont... | direct |
| epA | 0..1 Float |
DELTAMODE: The real current error for phase A or triplex phase | direct |
| epB | 0..1 Float |
DELTAMODE: The real current error for phase B | direct |
| epC | 0..1 Float |
DELTAMODE: The real current error for phase C | direct |
| eqA | 0..1 Float |
DELTAMODE: The reactive current error for phase A or triplex phase | direct |
| eqB | 0..1 Float |
DELTAMODE: The reactive current error for phase B | direct |
| eqC | 0..1 Float |
DELTAMODE: The reactive current error for phase C | direct |
| delta_epA | 0..1 Float |
DELTAMODE: The change in real current error for phase A or triplex phase | direct |
| delta_epB | 0..1 Float |
DELTAMODE: The change in real current error for phase B | direct |
| delta_epC | 0..1 Float |
DELTAMODE: The change in real current error for phase C | direct |
| delta_eqA | 0..1 Float |
DELTAMODE: The change in reactive current error for phase A or triplex phase | direct |
| delta_eqB | 0..1 Float |
DELTAMODE: The change in reactive current error for phase B | direct |
| delta_eqC | 0..1 Float |
DELTAMODE: The change in reactive current error for phase C | direct |
| mdA | 0..1 Float |
DELTAMODE: The d-axis current modulation for phase A or triplex phase | direct |
| mdB | 0..1 Float |
DELTAMODE: The d-axis current modulation for phase B | direct |
| mdC | 0..1 Float |
DELTAMODE: The d-axis current modulation for phase C | direct |
| mqA | 0..1 Float |
DELTAMODE: The q-axis current modulation for phase A or triplex phase | direct |
| mqB | 0..1 Float |
DELTAMODE: The q-axis current modulation for phase B | direct |
| mqC | 0..1 Float |
DELTAMODE: The q-axis current modulation for phase C | direct |
| delta_mdA | 0..1 Float |
DELTAMODE: The change in d-axis current modulation for phase A or triplex pha... | direct |
| delta_mdB | 0..1 Float |
DELTAMODE: The change in d-axis current modulation for phase B | direct |
| delta_mdC | 0..1 Float |
DELTAMODE: The change in d-axis current modulation for phase C | direct |
| delta_mqA | 0..1 Float |
DELTAMODE: The change in q-axis current modulation for phase A or triplex pha... | direct |
| delta_mqB | 0..1 Float |
DELTAMODE: The change in q-axis current modulation for phase B | direct |
| delta_mqC | 0..1 Float |
DELTAMODE: The change in q-axis current modulation for phase C | direct |
| IdqA | 0..1 Complex |
DELTAMODE: The dq-axis current for phase A or triplex phase | direct |
| IdqB | 0..1 Complex |
DELTAMODE: The dq-axis current for phase B | direct |
| IdqC | 0..1 Complex |
DELTAMODE: The dq-axis current for phase C | direct |
| Tfreq_delay | 0..1 Float |
DELTAMODE: The time constant for delayed frequency seen by the inverter | direct |
| inverter_droop_fp | 0..1 Boolean |
DELTAMODE: Boolean used to indicate whether inverter f/p droop is included or... | direct |
| R_fp | 0..1 Float |
DELTAMODE: The droop parameter of the f/p droop | direct |
| kppmax | 0..1 Float |
DELTAMODE: The proportional gain of Pmax controller | direct |
| kipmax | 0..1 Float |
DELTAMODE: The integral gain of Pmax controller | direct |
| Pmax | 0..1 Float |
DELTAMODE: power limit of grid forming inverter | direct |
| Pmin | 0..1 Float |
DELTAMODE: power limit of grid forming inverter | direct |
| Pmax_Low_Limit | 0..1 Float |
DELTAMODE: output limit of Pmax controller | direct |
| Tvol_delay | 0..1 Float |
DELTAMODE: The time constant for delayed voltage seen by the inverter | direct |
| inverter_droop_vq | 0..1 Boolean |
DELTAMODE: Boolean used to indicate whether inverter q/v droop is included or... | direct |
| R_vq | 0..1 Float |
DELTAMODE: The droop parameter of the v/q droop | direct |
| Tp_delay | 0..1 Float |
DELTAMODE: The time constant for delayed real power seen by the VSI droop con... | direct |
| Tq_delay | 0..1 Float |
DELTAMODE: The time constant for delayed reactive power seen by the VSI droop... | direct |
| VSI_Rfilter | 0..1 Complex |
VSI filter resistance (p | direct |
| VSI_Xfilter | 0..1 Complex |
VSI filter inductance (p | direct |
| VSI_mode | 0..1 String |
VSI MODEL: Selects VSI mode for either isochronous or droop one | direct |
| VSI_freq | 0..1 Float |
VSI frequency | direct |
| ki_Vterminal | 0..1 Float |
DELTAMODE: The integrator gain for the VSI terminal voltage modulation | direct |
| kp_Vterminal | 0..1 Float |
DELTAMODE: The proportional gain for the VSI terminal voltage modulation | direct |
| V_set_droop | 0..1 Float |
DELTAMODE: The voltage setpoint of droop control | direct |
| V_set0 | 0..1 Float |
DELTAMODE: The voltage setpoint of grid-following Q-V droop control | direct |
| V_set1 | 0..1 Float |
DELTAMODE: The voltage setpoint of grid-following Q-V droop control | direct |
| V_set2 | 0..1 Float |
DELTAMODE: The voltage setpoint of grid-following Q-V droop control | direct |
| enable_ramp_rates_real | 0..1 Boolean |
DELTAMODE: Boolean used to indicate whether inverter ramp rate is enforced or... | direct |
| max_ramp_up_real | 0..1 Float |
DELTAMODE: The real power ramp up rate limit | direct |
| max_ramp_down_real | 0..1 Float |
DELTAMODE: The real power ramp down rate limit | direct |
| enable_ramp_rates_reactive | 0..1 Boolean |
DELTAMODE: Boolean used to indicate whether inverter ramp rate is enforced or... | direct |
| max_ramp_up_reactive | 0..1 Float |
DELTAMODE: The reactive power ramp up rate limit | direct |
| max_ramp_down_reactive | 0..1 Float |
DELTAMODE: The reactive power ramp down rate limit | direct |
| dynamic_model_mode | 0..1 String |
DELTAMODE: Underlying model to use for deltamode control | direct |
| enable_1547_checks | 0..1 Boolean |
DELTAMODE: Enable IEEE 1547-2003 disconnect checking | direct |
| reconnect_time | 0..1 Float |
DELTAMODE: Time delay after IEEE 1547-2003 violation clears before resuming g... | direct |
| inverter_1547_status | 0..1 Boolean |
DELTAMODE: Indicator if the inverter is curtailed due to a 1547 violation or ... | direct |
| IEEE_1547_version | 0..1 Ieee1547Version |
DELTAMODE: Version of IEEE 1547 to use to populate defaults | direct |
| over_freq_high_cutout | 0..1 Float |
DELTAMODE: OF2 set point for IEEE 1547a | direct |
| over_freq_high_disconnect_time | 0..1 Float |
DELTAMODE: OF2 clearing time for IEEE1547a | direct |
| over_freq_low_cutout | 0..1 Float |
DELTAMODE: OF1 set point for IEEE 1547a | direct |
| over_freq_low_disconnect_time | 0..1 Float |
DELTAMODE: OF1 clearing time for IEEE 1547a | direct |
| under_freq_high_cutout | 0..1 Float |
DELTAMODE: UF2 set point for IEEE 1547a | direct |
| under_freq_high_disconnect_time | 0..1 Float |
DELTAMODE: UF2 clearing time for IEEE1547a | direct |
| under_freq_low_cutout | 0..1 Float |
DELTAMODE: UF1 set point for IEEE 1547a | direct |
| under_freq_low_disconnect_time | 0..1 Float |
DELTAMODE: UF1 clearing time for IEEE 1547a | direct |
| under_voltage_low_cutout | 0..1 Float |
Lowest voltage threshold for undervoltage | direct |
| under_voltage_middle_cutout | 0..1 Float |
Middle-lowest voltage threshold for undervoltage | direct |
| under_voltage_high_cutout | 0..1 Float |
High value of low voltage threshold for undervoltage | direct |
| over_voltage_low_cutout | 0..1 Float |
Lowest voltage value for overvoltage | direct |
| over_voltage_high_cutout | 0..1 Float |
High voltage value for overvoltage | direct |
| under_voltage_low_disconnect_time | 0..1 Float |
Lowest voltage clearing time for undervoltage | direct |
| under_voltage_middle_disconnect_time | 0..1 Float |
Middle-lowest voltage clearing time for undervoltage | direct |
| under_voltage_high_disconnect_time | 0..1 Float |
Highest voltage clearing time for undervoltage | direct |
| over_voltage_low_disconnect_time | 0..1 Float |
Lowest voltage clearing time for overvoltage | direct |
| over_voltage_high_disconnect_time | 0..1 Float |
Highest voltage clearing time for overvoltage | direct |
| IEEE_1547_trip_method | 0..1 Ieee1547TripMethod |
High over-voltage level trip | direct |
| phases | 0..1 String |
The phases the inverter is attached to | direct |
| use_multipoint_efficiency | 0..1 Boolean |
FOUR QUADRANT MODEL: boolean to used the multipoint efficiency curve for the ... | direct |
| inverter_manufacturer | 0..1 String |
MULTIPOINT EFFICIENCY MODEL: the manufacturer of the inverter to setup up pre... | direct |
| maximum_dc_power | 0..1 Float |
MULTIPOINT EFFICIENCY MODEL: the maximum dc power point for the efficiency cu... | direct |
| maximum_dc_voltage | 0..1 Float |
MULTIPOINT EFFICIENCY MODEL: the maximum dc voltage point for the efficiency ... | direct |
| minimum_dc_power | 0..1 Float |
MULTIPOINT EFFICIENCY MODEL: the minimum dc power point for the efficiency cu... | direct |
| c_0 | 0..1 Float |
MULTIPOINT EFFICIENCY MODEL: the first coefficient in the efficiency curve | direct |
| c_1 | 0..1 Float |
MULTIPOINT EFFICIENCY MODEL: the second coefficient in the efficiency curve | direct |
| c_2 | 0..1 Float |
MULTIPOINT EFFICIENCY MODEL: the third coefficient in the efficiency curve | direct |
| c_3 | 0..1 Float |
MULTIPOINT EFFICIENCY MODEL: the fourth coefficient in the efficiency curve | direct |
| sense_object | 0..1 String |
FOUR QUADRANT MODEL: name of the object the inverter is trying to mitigate th... | direct |
| max_charge_rate | 0..1 Float |
FOUR QUADRANT MODEL: maximum rate the battery can be charged in LOAD_FOLLOWIN... | direct |
| max_discharge_rate | 0..1 Float |
FOUR QUADRANT MODEL: maximum rate the battery can be discharged in LOAD_FOLLO... | direct |
| charge_on_threshold | 0..1 Float |
FOUR QUADRANT MODEL: power level at which the inverter should try charging th... | direct |
| charge_off_threshold | 0..1 Float |
FOUR QUADRANT MODEL: power level at which the inverter should cease charging ... | direct |
| discharge_on_threshold | 0..1 Float |
FOUR QUADRANT MODEL: power level at which the inverter should try discharging... | direct |
| discharge_off_threshold | 0..1 Float |
FOUR QUADRANT MODEL: power level at which the inverter should cease dischargi... | direct |
| excess_input_power | 0..1 Float |
FOUR QUADRANT MODEL: Excess power at the input of the inverter that is otherw... | direct |
| charge_lockout_time | 0..1 Float |
FOUR QUADRANT MODEL: Lockout time when a charging operation occurs before ano... | direct |
| discharge_lockout_time | 0..1 Float |
FOUR QUADRANT MODEL: Lockout time when a discharging operation occurs before ... | direct |
| pf_reg_activate | 0..1 Float |
FOUR QUADRANT MODEL: Lowest acceptable power-factor level below which power-f... | direct |
| pf_reg_deactivate | 0..1 Float |
FOUR QUADRANT MODEL: Lowest acceptable power-factor above which no power-fact... | direct |
| pf_target | 0..1 Float |
FOUR QUADRANT MODEL: Desired power-factor to maintain (signed) positive is in... | direct |
| pf_reg_high | 0..1 Float |
FOUR QUADRANT MODEL: Upper limit for power-factor - if exceeds, go full rever... | direct |
| pf_reg_low | 0..1 Float |
FOUR QUADRANT MODEL: Lower limit for power-factor - if exceeds, stop regulati... | direct |
| pf_reg_activate_lockout_time | 0..1 Float |
FOUR QUADRANT MODEL: Mandatory pause between the deactivation of power-factor... | direct |
| disable_volt_var_if_no_input_power | 0..1 Boolean |
direct | |
| delay_time | 0..1 Float |
direct | |
| max_var_slew_rate | 0..1 Float |
direct | |
| max_pwr_slew_rate | 0..1 Float |
direct | |
| volt_var_sched | 0..1 String |
direct | |
| freq_pwr_sched | 0..1 String |
direct | |
| charge_threshold | 0..1 Float |
FOUR QUADRANT MODEL: Level at which all inverters in the group will begin cha... | direct |
| discharge_threshold | 0..1 Float |
FOUR QUADRANT MODEL: Level at which all inverters in the group will begin dis... | direct |
| group_max_charge_rate | 0..1 Float |
FOUR QUADRANT MODEL: Sum of the charge rates of the batteries involved in the... | direct |
| group_max_discharge_rate | 0..1 Float |
FOUR QUADRANT MODEL: Sum of the discharge rates of the batteries involved in ... | direct |
| group_rated_power | 0..1 Float |
FOUR QUADRANT MODEL: Sum of the inverter power ratings of the inverters invol... | direct |
| V_base | 0..1 Float |
FOUR QUADRANT MODEL: The base voltage on the grid side of the inverter | direct |
| V1 | 0..1 Float |
FOUR QUADRANT MODEL: voltage point 1 in volt/var curve | direct |
| Q1 | 0..1 Float |
FOUR QUADRANT MODEL: VAR point 1 in volt/var curve | direct |
| V2 | 0..1 Float |
FOUR QUADRANT MODEL: voltage point 2 in volt/var curve | direct |
| Q2 | 0..1 Float |
FOUR QUADRANT MODEL: VAR point 2 in volt/var curve | direct |
| V3 | 0..1 Float |
FOUR QUADRANT MODEL: voltage point 3 in volt/var curve | direct |
| Q3 | 0..1 Float |
FOUR QUADRANT MODEL: VAR point 3 in volt/var curve | direct |
| V4 | 0..1 Float |
FOUR QUADRANT MODEL: voltage point 4 in volt/var curve | direct |
| Q4 | 0..1 Float |
FOUR QUADRANT MODEL: VAR point 4 in volt/var curve | direct |
| volt_var_control_lockout | 0..1 Float |
FOUR QUADRANT QUADRANT MODEL: the lockout time between volt/var actions | direct |
| number_of_phases_out | 0..1 Integer |
Exposed variable - hidden for solar | direct |
| efficiency_value | 0..1 Float |
Exposed variable - hidden for solar | direct |
| VW_V1 | 0..1 Float |
FOUR QUADRANT MODEL: Voltage at which power limiting begins (e | direct |
| VW_V2 | 0..1 Float |
FOUR QUADRANT MODEL: Voltage at which power limiting ends | direct |
| VW_P1 | 0..1 Float |
FOUR QUADRANT MODEL: Power limit at VW_P1 (e | direct |
| VW_P2 | 0..1 Float |
FOUR QUADRANT MODEL: Power limit at VW_P2 (e | direct |
| WT_is_connected | 0..1 Boolean |
Internal flag that indicates a wind turbine child is connected | direct |
| pf_reg_status | 0..1 String |
CHECKPOINT_VAR: internal variable for pf_reg_status | direct |
| load_follow_status | 0..1 String |
CHECKPOINT_VAR: Status variable for what the load_following mode is doing | direct |
| last_current_A | 0..1 Complex |
CHECKPOINT_VAR: Previously applied power output (used to remove from parent s... | direct |
| last_current_B | 0..1 Complex |
CHECKPOINT_VAR: Previously applied power output (used to remove from parent s... | direct |
| last_current_C | 0..1 Complex |
CHECKPOINT_VAR: Previously applied power output (used to remove from parent s... | direct |
| last_current_D | 0..1 Complex |
CHECKPOINT_VAR: Previously applied power output (used to remove from parent s... | direct |
| last_power_A | 0..1 Complex |
CHECKPOINT_VAR: Previously applied power output (as constant power) - used to... | direct |
| last_power_B | 0..1 Complex |
CHECKPOINT_VAR: Previously applied power output (as constant power) - used to... | direct |
| last_power_C | 0..1 Complex |
CHECKPOINT_VAR: Previously applied power output (as constant power) - used to... | direct |
| last_power_D | 0..1 Complex |
CHECKPOINT_VAR: Previously applied power output (as constant power) - used to... | direct |
| inverter_first_step | 0..1 Boolean |
CHECKPOINT_VAR: internal variable for inverter_first_step | direct |
| first_iteration_current_injection | 0..1 Integer |
CHECKPOINT_VAR: Initialization variable - mostly so SWING_PQ buses initalize ... | direct |
| m12 | 0..1 Float |
CHECKPOINT_VAR: internal variable for m12 | direct |
| b12 | 0..1 Float |
CHECKPOINT_VAR: internal variable for b12 | direct |
| m23 | 0..1 Float |
CHECKPOINT_VAR: internal variable for m23 | direct |
| b23 | 0..1 Float |
CHECKPOINT_VAR: internal variable for b23 | direct |
| m34 | 0..1 Float |
CHECKPOINT_VAR: internal variable for m34 | direct |
| b34 | 0..1 Float |
CHECKPOINT_VAR: internal variable for b34 | direct |
| allowed_vv_action | 0..1 String |
CHECKPOINT_VAR: internal variable for allowed_vv_action | direct |
| last_vv_check | 0..1 String |
CHECKPOINT_VAR: internal variable for last_vv_check | direct |
| IEEE_1547_STATUS | 0..1 String |
CHECKPOINT_VAR: internal variable for ieee_1547_version | direct |
| over_freq_high_band_viol_time | 0..1 Float |
CHECKPOINT_VAR: OF2 violation accumulator | direct |
| over_freq_low_band_viol_time | 0..1 Float |
CHECKPOINT_VAR: OF1 violation accumulator | direct |
| under_freq_low_band_viol_time | 0..1 Float |
CHECKPOINT_VAR: UF1 violation accumulator | direct |
| under_voltage_lowest_viol_time | 0..1 Float |
CHECKPOINT_VAR: Lowest low voltage threshold violation accumulator | direct |
| under_voltage_middle_viol_time | 0..1 Float |
CHECKPOINT_VAR: Middle low voltage threshold violation accumulator | direct |
| under_voltage_high_viol_time | 0..1 Float |
CHECKPOINT_VAR: Highest low voltage threshold violation accumulator | direct |
| over_voltage_low_viol_time | 0..1 Float |
CHECKPOINT_VAR: Lowest high voltage threshold violation accumulator | direct |
| over_voltage_high_viol_time | 0..1 Float |
CHECKPOINT_VAR: Highest high voltage threshold violation accumulator | direct |
| lf_dispatch_power | 0..1 Float |
CHECKPOINT_VAR: Amount of real power to try and dispatch to meet thresholds | direct |
| next_update_time | 0..1 String |
CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed | direct |
| lf_dispatch_change_allowed | 0..1 Boolean |
CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed | direct |
| pf_reg_dispatch_change_allowed | 0..1 Boolean |
CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed for power... | direct |
| pf_reg_dispatch_VAR | 0..1 Float |
CHECKPOINT_VAR: (Reactive only?) power dispatched to meet power factor regula... | direct |
| pf_reg_next_update_time | 0..1 String |
CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed | direct |
| prev_time | 0..1 String |
CHECKPOINT_VAR: Tracking variable for previous "new time" run | direct |
| prev_time_dbl | 0..1 Float |
CHECKPOINT_VAR: Tracking variable for 1547 checks and ramp rates | direct |
| event_deltat | 0..1 Float |
CHECKPOINT_VAR: Event-driven delta-t variable | direct |
| start_time | 0..1 String |
CHECKPOINT_VAR: Recording start time of simulation | direct |
| last_I_Out_A | 0..1 Complex |
CHECKPOINT_VAR: internal variable for last_I_Out[0] | direct |
| last_I_Out_B | 0..1 Complex |
CHECKPOINT_VAR: internal variable for last_I_Out[1] | direct |
| last_I_Out_C | 0..1 Complex |
CHECKPOINT_VAR: internal variable for last_I_Out[2] | direct |
| last_I_In | 0..1 Float |
CHECKPOINT_VAR: internal variable for last_I_In | direct |
| pa_vw_limited | 0..1 Float |
CHECKPOINT_VAR: internal variable for pa_vw_limited | direct |
| pb_vw_limited | 0..1 Float |
CHECKPOINT_VAR: internal variable for pb_vw_limited | direct |
| pc_vw_limited | 0..1 Float |
CHECKPOINT_VAR: internal variable for pc_vw_limited | direct |
| out_of_violation_time_total | 0..1 Float |
CHECKPOINT_VAR: internal variable for out_of_violation_time_total | direct |
| deltamode_inclusive | 0..1 Boolean |
CHECKPOINT_VAR: Boolean for deltamode calls - pulled from object flags | direct |
| first_sync_delta_enabled | 0..1 Boolean |
CHECKPOINT_VAR: internal variable for first_sync_delta_enabled | direct |
| first_iter_counter | 0..1 String |
CHECKPOINT_VAR: internal variable for first_iter_counter | direct |
| first_run | 0..1 Boolean |
CHECKPOINT_VAR: internal variable for first_run | direct |
| prev_value_IGenerated_A | 0..1 Complex |
CHECKPOINT_VAR: internal variable for prev_value_IGenerated[0] | direct |
| prev_value_IGenerated_B | 0..1 Complex |
CHECKPOINT_VAR: internal variable for prev_value_IGenerated[1] | direct |
| prev_value_IGenerated_C | 0..1 Complex |
CHECKPOINT_VAR: internal variable for prev_value_IGenerated[2] | direct |
| name | 1 String |
The object's name; unique across the model | GlmObject |
| parent | 0..1 String |
The parent object's name | GlmObject |
| groupid | 0..1 String |
Free-text group label | GlmObject |
| latitude | 0..1 String |
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) | GlmObject |
| longitude | 0..1 String |
Longitude, as written | GlmObject |
| in_svc | 0..1 String |
Timestamp the object enters service | GlmObject |
| out_svc | 0..1 String |
Timestamp the object leaves service | GlmObject |
| rank | 0..1 String |
Solver rank | GlmObject |
| flags | 0..1 String |
Core object flags | GlmObject |
Comments¶
- Import: PowerElectronicsConnection, mRID pv_ or storage_ + name by its solar or battery child (inverter.cimtbl), with a GenerationInverterInfo or StorageInverterInfo datasheet; one child is mapped, GridLAB-D has no delta inverter. Export: each PowerElectronicsConnection, one inverter per unit (name_
when several), parented to its bus.
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridlabd.org/schema/glm
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | glm:Inverter |
| native | glm:Inverter |
| exact | cim:PowerElectronicsConnection |
| close | cim:GenerationInverterInfo, cim:StorageInverterInfo |
LinkML Source¶
Direct¶
name: inverter
description: 'Copyright (C) 2008 Battelle Memorial Institute
@file inverter.cpp
@defgroup inverter
@ingroup generators
@{
Inherits from: gld_object
Type: Instance (network topology element)
Note: Inherits from gld_object (not in generators module)'
comments:
- 'Import: PowerElectronicsConnection, mRID pv_ or storage_ + name by its solar or
battery child (inverter.cimtbl), with a GenerationInverterInfo or StorageInverterInfo
datasheet; one child is mapped, GridLAB-D has no delta inverter. Export: each PowerElectronicsConnection,
one inverter per unit (name_<n> when several), parented to its bus.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PowerElectronicsConnection
close_mappings:
- cim:GenerationInverterInfo
- cim:StorageInverterInfo
is_a: glm_object
attributes:
inverter_type:
name: inverter_type
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: inverter_type
description: 'LEGACY MODEL: Sets efficiencies and other parameters; if using four_quadrant_control_mode,
set this to FOUR_QUADRANT'
comments:
- 'Import: structural; FOUR_QUADRANT only, any other raises (unset is GridLAB-D''s
PWM). Export: FOUR_QUADRANT.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
four_quadrant_control_mode:
name: four_quadrant_control_mode
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: four_quadrant_control_mode
description: 'FOUR QUADRANT MODEL: Activates various control modes'
comments:
- 'Import: structural; CONSTANT_PF on a solar, CONSTANT_PQ on a battery (which
also reads CONSTANT_PF), others raise; the mode''s capability flag goes in the
row comment, InverterCapabilities is not written yet. Export: CONSTANT_PQ on
a battery, CONSTANT_PF on a PV.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
pf_reg:
name: pf_reg
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: pf_reg
description: Activate (or not) power factor regulation in four_quadrant_control_mode
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
generator_status:
name: generator_status
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: generator_status
description: describes whether the generator is online or offline
comments:
- 'Import: ONLINE (default) is normallyInService true, OFFLINE false and the output
0. Export: OFFLINE when normallyInService is false, else ONLINE.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:Equipment.normallyInService
domain_of:
- battery
- inverter
range: string
required: false
generator_mode:
name: generator_mode
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: generator_mode
description: 'LEGACY MODEL: Selects generator control mode when using legacy model;
in non-legacy models, this should be SUPPLY_DRIVEN.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- battery
- inverter
- rectifier
range: GeneratorMode
required: false
inverter_convergence_criterion:
name: inverter_convergence_criterion
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: inverter_convergence_criterion
description: The maximum change in error threshold for exitting deltamode.
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
current_convergence:
name: current_convergence
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: current_convergence[A]
description: Convergence criterion for current changes on first timestep - basically
initialization of system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- diesel_dg
- inverter
range: float
required: false
unit:
ucum_code: A
V_In:
name: V_In
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_In[V]
description: DC voltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: V
I_In:
name: I_In
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: I_In[A]
description: DC current
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- battery
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: A
P_In:
name: P_In
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: P_In[W]
description: DC power
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: W
VA_Out:
name: VA_Out
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: VA_Out[VA]
description: AC power
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- battery
- inverter
- inverter_dyn
- rectifier
range: Complex
required: false
unit:
ucum_code: VA
Vdc:
name: Vdc
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Vdc[V]
description: 'LEGACY MODEL: DC voltage'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: V
phaseA_V_Out:
name: phaseA_V_Out
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseA_V_Out[V]
description: AC voltage on A phase in three-phase system; 240-V connection on
a triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: V
phaseB_V_Out:
name: phaseB_V_Out
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseB_V_Out[V]
description: AC voltage on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: V
phaseC_V_Out:
name: phaseC_V_Out
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseC_V_Out[V]
description: AC voltage on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: V
phaseA_I_Out:
name: phaseA_I_Out
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseA_I_Out[V]
description: AC current on A phase in three-phase system; 240-V connection on
a triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: Complex
required: false
unit:
ucum_code: V
phaseB_I_Out:
name: phaseB_I_Out
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseB_I_Out[V]
description: AC current on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: Complex
required: false
unit:
ucum_code: V
phaseC_I_Out:
name: phaseC_I_Out
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseC_I_Out[V]
description: AC current on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: Complex
required: false
unit:
ucum_code: V
power_A:
name: power_A
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_A[VA]
description: AC power on A phase in three-phase system; 240-V connection on a
triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_B:
name: power_B
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_B[VA]
description: AC power on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_C:
name: power_C
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_C[VA]
description: AC power on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
curr_VA_out_A:
name: curr_VA_out_A
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: curr_VA_out_A[VA]
description: AC power on A phase in three-phase system; 240-V connection on a
triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
curr_VA_out_B:
name: curr_VA_out_B
annotations:
order:
tag: order
value: 23
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: curr_VA_out_B[VA]
description: AC power on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
curr_VA_out_C:
name: curr_VA_out_C
annotations:
order:
tag: order
value: 24
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: curr_VA_out_C[VA]
description: AC power on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
prev_VA_out_A:
name: prev_VA_out_A
annotations:
order:
tag: order
value: 25
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_VA_out_A[VA]
description: AC power on A phase in three-phase system; 240-V connection on a
triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
prev_VA_out_B:
name: prev_VA_out_B
annotations:
order:
tag: order
value: 26
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_VA_out_B[VA]
description: AC power on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
prev_VA_out_C:
name: prev_VA_out_C
annotations:
order:
tag: order
value: 27
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_VA_out_C[VA]
description: AC power on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
e_source_A:
name: e_source_A
annotations:
order:
tag: order
value: 28
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: e_source_A
description: 'DELTAMODE: Internal voltage of grid-forming source, phase A'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
e_source_B:
name: e_source_B
annotations:
order:
tag: order
value: 29
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: e_source_B
description: 'DELTAMODE: Internal voltage of grid-forming source, phase B'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
e_source_C:
name: e_source_C
annotations:
order:
tag: order
value: 30
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: e_source_C
description: 'DELTAMODE: Internal voltage of grid-forming source, phase C'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
V_angle_A:
name: V_angle_A
annotations:
order:
tag: order
value: 31
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_angle_A
description: 'DELTAMODE: Internal angle of grid-forming source, phase A'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
V_angle_B:
name: V_angle_B
annotations:
order:
tag: order
value: 32
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_angle_B
description: 'DELTAMODE: Internal angle of grid-forming source, phase B'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
V_angle_C:
name: V_angle_C
annotations:
order:
tag: order
value: 33
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_angle_C
description: 'DELTAMODE: Internal angle of grid-forming source, phase C'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
phaseA_I_Forming:
name: phaseA_I_Forming
annotations:
order:
tag: order
value: 34
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseA_I_Forming[A]
description: AC current on A phase in three-phase system, only for grid_forming
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseB_I_Forming:
name: phaseB_I_Forming
annotations:
order:
tag: order
value: 35
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseB_I_Forming[A]
description: AC current on B phase in three-phase system, only for grid_forming
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseC_I_Forming:
name: phaseC_I_Forming
annotations:
order:
tag: order
value: 36
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseC_I_Forming[A]
description: AC current on C phase in three-phase system, only for grid_forming
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseA_I_Following:
name: phaseA_I_Following
annotations:
order:
tag: order
value: 37
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseA_I_Following[A]
description: AC current on A phase in three-phase system, only for grid_following
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseB_I_Following:
name: phaseB_I_Following
annotations:
order:
tag: order
value: 38
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseB_I_Following[A]
description: AC current on B phase in three-phase system, only for grid_following
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseC_I_Following:
name: phaseC_I_Following
annotations:
order:
tag: order
value: 39
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseC_I_Following[A]
description: AC current on C phase in three-phase system, only for grid_following
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
pCircuit_V_Avg:
name: pCircuit_V_Avg
annotations:
order:
tag: order
value: 40
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pCircuit_V_Avg
description: 'DELTAMODE: three-phase average value of terminal voltage'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
P_Out:
name: P_Out
annotations:
order:
tag: order
value: 41
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: P_Out[VA]
description: 'FOUR QUADRANT MODEL: Scheduled real power out in CONSTANT_PQ control
mode'
comments:
- 'Import: a battery''s CONSTANT_PQ set point, limited by ratedS, a full battery
or the reserve, is p (W, load sign) and gives batteryState; a PV''s is an output
GridLAB-D overwrites, so only in the row comment. Export: a battery''s p from
get_inverter_units, generation sign.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.p
- cim:BatteryUnit.batteryState
rank: 1000
domain_of:
- inverter
- solar
range: float
required: false
unit:
ucum_code: VA
Q_Out:
name: Q_Out
annotations:
order:
tag: order
value: 42
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q_Out[VAr]
description: 'FOUR QUADRANT MODEL: Schedule reactive power out in CONSTANT_PQ
control mode'
comments:
- 'Import: q (VAr) is 0 when unset or 0; any other value raises. Export: a battery''s
q, generation sign.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.q
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: VAr
power_in:
name: power_in
annotations:
order:
tag: order
value: 43
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: power_in[W]
description: 'LEGACY MODEL: No longer used'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- link
- inverter
range: float
required: false
unit:
ucum_code: W
rated_power:
name: rated_power
annotations:
order:
tag: order
value: 44
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: rated_power[VA]
description: 'FOUR QUADRANT MODEL: The rated power of the inverter'
comments:
- 'Import: ratedS (VA) = rated_power x the phases out (3, 2, 1; S is 1); maxQ
= -minQ = ratedS, and the datasheet''s apparentPowerMaximum; unset or 0 raises.
Export: ratedS x the unit''s share / phases.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.ratedS
- cim:PowerElectronicsConnection.maxQ
- cim:PowerElectronicsConnection.minQ
- cim:GridEdgeDeviceInfo.apparentPowerMaximum
domain_of:
- battery
- inverter
- inverter_dyn
- solar
range: float
required: false
unit:
ucum_code: VA
rated_battery_power:
name: rated_battery_power
annotations:
order:
tag: order
value: 45
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: rated_battery_power[W]
description: 'FOUR QUADRANT MODEL: The rated power of battery when battery is
attached'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
inverter_efficiency:
name: inverter_efficiency
annotations:
order:
tag: order
value: 46
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: inverter_efficiency
description: 'FOUR QUADRANT MODEL: The efficiency of the inverter'
comments:
- 'Import: PV AC = DC x inverter_efficiency (default 0.9) is folded into p; CIM
has no inverter efficiency. Export: 1 on a PV; the losses are in p.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
domain_of:
- inverter
range: float
required: false
battery_soc:
name: battery_soc
annotations:
order:
tag: order
value: 47
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: battery_soc[pu]
description: 'FOUR QUADRANT MODEL: The state of charge of an attached battery'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
soc_reserve:
name: soc_reserve
annotations:
order:
tag: order
value: 48
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: soc_reserve[pu]
description: 'FOUR QUADRANT MODEL: The reserve state of charge of an attached
battery for islanding cases'
comments:
- 'Import: BatteryUnit.minimumE (Wh) = soc_reserve x battery_capacity; default
0. Export: minimumE / ratedE.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:BatteryUnit.minimumE
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
power_factor:
name: power_factor
annotations:
order:
tag: order
value: 49
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: power_factor[unit]
description: 'FOUR QUADRANT MODEL: The power factor used for CONSTANT_PF control
mode'
comments:
- 'Import: CONSTANT_PF q is 0 when |pf| is 1; |pf| < 1 raises. Export: a PV''s
p / |p + jq|, negative when q is.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.q
domain_of:
- performance_motor
- battery
- inverter
- windturb_dg
- residential_enduse
range: float
required: false
unit:
ucum_code: unit
islanded_state:
name: islanded_state
annotations:
order:
tag: order
value: 50
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: islanded_state
description: 'FOUR QUADRANT MODEL: Boolean used to let control modes to act under
island conditions'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
nominal_frequency:
name: nominal_frequency
annotations:
order:
tag: order
value: 51
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: nominal_frequency[Hz]
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: Hz
Pref:
name: Pref
annotations:
order:
tag: order
value: 52
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pref
description: 'DELTAMODE: The real power reference.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- diesel_dg
- inverter
- inverter_dyn
range: float
required: false
Qref:
name: Qref
annotations:
order:
tag: order
value: 53
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Qref
description: 'DELTAMODE: The reactive power reference.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- diesel_dg
- inverter
- inverter_dyn
range: float
required: false
kpd:
name: kpd
annotations:
order:
tag: order
value: 54
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kpd
description: 'DELTAMODE: The d-axis integration gain for the current modulation
PI controller.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
kpq:
name: kpq
annotations:
order:
tag: order
value: 55
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kpq
description: 'DELTAMODE: The q-axis integration gain for the current modulation
PI controller.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
kid:
name: kid
annotations:
order:
tag: order
value: 56
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kid
description: 'DELTAMODE: The d-axis proportional gain for the current modulation
PI controller.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
kiq:
name: kiq
annotations:
order:
tag: order
value: 57
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kiq
description: 'DELTAMODE: The q-axis proportional gain for the current modulation
PI controller.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
kdd:
name: kdd
annotations:
order:
tag: order
value: 58
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kdd
description: 'DELTAMODE: The d-axis differentiator gain for the current modulation
PID controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
kdq:
name: kdq
annotations:
order:
tag: order
value: 59
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kdq
description: 'DELTAMODE: The q-axis differentiator gain for the current modulation
PID controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
epA:
name: epA
annotations:
order:
tag: order
value: 60
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: epA
description: 'DELTAMODE: The real current error for phase A or triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
epB:
name: epB
annotations:
order:
tag: order
value: 61
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: epB
description: 'DELTAMODE: The real current error for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
epC:
name: epC
annotations:
order:
tag: order
value: 62
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: epC
description: 'DELTAMODE: The real current error for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
eqA:
name: eqA
annotations:
order:
tag: order
value: 63
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: eqA
description: 'DELTAMODE: The reactive current error for phase A or triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
eqB:
name: eqB
annotations:
order:
tag: order
value: 64
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: eqB
description: 'DELTAMODE: The reactive current error for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
eqC:
name: eqC
annotations:
order:
tag: order
value: 65
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: eqC
description: 'DELTAMODE: The reactive current error for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_epA:
name: delta_epA
annotations:
order:
tag: order
value: 66
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_epA
description: 'DELTAMODE: The change in real current error for phase A or triplex
phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_epB:
name: delta_epB
annotations:
order:
tag: order
value: 67
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_epB
description: 'DELTAMODE: The change in real current error for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_epC:
name: delta_epC
annotations:
order:
tag: order
value: 68
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_epC
description: 'DELTAMODE: The change in real current error for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_eqA:
name: delta_eqA
annotations:
order:
tag: order
value: 69
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_eqA
description: 'DELTAMODE: The change in reactive current error for phase A or triplex
phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_eqB:
name: delta_eqB
annotations:
order:
tag: order
value: 70
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_eqB
description: 'DELTAMODE: The change in reactive current error for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_eqC:
name: delta_eqC
annotations:
order:
tag: order
value: 71
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_eqC
description: 'DELTAMODE: The change in reactive current error for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
mdA:
name: mdA
annotations:
order:
tag: order
value: 72
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mdA
description: 'DELTAMODE: The d-axis current modulation for phase A or triplex
phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
mdB:
name: mdB
annotations:
order:
tag: order
value: 73
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mdB
description: 'DELTAMODE: The d-axis current modulation for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
mdC:
name: mdC
annotations:
order:
tag: order
value: 74
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mdC
description: 'DELTAMODE: The d-axis current modulation for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
mqA:
name: mqA
annotations:
order:
tag: order
value: 75
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mqA
description: 'DELTAMODE: The q-axis current modulation for phase A or triplex
phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
mqB:
name: mqB
annotations:
order:
tag: order
value: 76
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mqB
description: 'DELTAMODE: The q-axis current modulation for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
mqC:
name: mqC
annotations:
order:
tag: order
value: 77
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mqC
description: 'DELTAMODE: The q-axis current modulation for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_mdA:
name: delta_mdA
annotations:
order:
tag: order
value: 78
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mdA
description: 'DELTAMODE: The change in d-axis current modulation for phase A or
triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_mdB:
name: delta_mdB
annotations:
order:
tag: order
value: 79
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mdB
description: 'DELTAMODE: The change in d-axis current modulation for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_mdC:
name: delta_mdC
annotations:
order:
tag: order
value: 80
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mdC
description: 'DELTAMODE: The change in d-axis current modulation for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_mqA:
name: delta_mqA
annotations:
order:
tag: order
value: 81
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mqA
description: 'DELTAMODE: The change in q-axis current modulation for phase A or
triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_mqB:
name: delta_mqB
annotations:
order:
tag: order
value: 82
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mqB
description: 'DELTAMODE: The change in q-axis current modulation for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
delta_mqC:
name: delta_mqC
annotations:
order:
tag: order
value: 83
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mqC
description: 'DELTAMODE: The change in q-axis current modulation for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
IdqA:
name: IdqA
annotations:
order:
tag: order
value: 84
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: IdqA
description: 'DELTAMODE: The dq-axis current for phase A or triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
IdqB:
name: IdqB
annotations:
order:
tag: order
value: 85
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: IdqB
description: 'DELTAMODE: The dq-axis current for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
IdqC:
name: IdqC
annotations:
order:
tag: order
value: 86
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: IdqC
description: 'DELTAMODE: The dq-axis current for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
Tfreq_delay:
name: Tfreq_delay
annotations:
order:
tag: order
value: 87
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tfreq_delay
description: 'DELTAMODE: The time constant for delayed frequency seen by the inverter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
inverter_droop_fp:
name: inverter_droop_fp
annotations:
order:
tag: order
value: 88
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: inverter_droop_fp
description: 'DELTAMODE: Boolean used to indicate whether inverter f/p droop is
included or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
R_fp:
name: R_fp
annotations:
order:
tag: order
value: 89
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_fp
description: 'DELTAMODE: The droop parameter of the f/p droop'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
kppmax:
name: kppmax
annotations:
order:
tag: order
value: 90
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kppmax
description: 'DELTAMODE: The proportional gain of Pmax controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
kipmax:
name: kipmax
annotations:
order:
tag: order
value: 91
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kipmax
description: 'DELTAMODE: The integral gain of Pmax controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
Pmax:
name: Pmax
annotations:
order:
tag: order
value: 92
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pmax
description: 'DELTAMODE: power limit of grid forming inverter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
Pmin:
name: Pmin
annotations:
order:
tag: order
value: 93
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pmin
description: 'DELTAMODE: power limit of grid forming inverter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
Pmax_Low_Limit:
name: Pmax_Low_Limit
annotations:
order:
tag: order
value: 94
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pmax_Low_Limit
description: 'DELTAMODE: output limit of Pmax controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
Tvol_delay:
name: Tvol_delay
annotations:
order:
tag: order
value: 95
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tvol_delay
description: 'DELTAMODE: The time constant for delayed voltage seen by the inverter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
inverter_droop_vq:
name: inverter_droop_vq
annotations:
order:
tag: order
value: 96
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: inverter_droop_vq
description: 'DELTAMODE: Boolean used to indicate whether inverter q/v droop is
included or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
R_vq:
name: R_vq
annotations:
order:
tag: order
value: 97
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_vq
description: 'DELTAMODE: The droop parameter of the v/q droop'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
Tp_delay:
name: Tp_delay
annotations:
order:
tag: order
value: 98
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tp_delay
description: 'DELTAMODE: The time constant for delayed real power seen by the
VSI droop controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
Tq_delay:
name: Tq_delay
annotations:
order:
tag: order
value: 99
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tq_delay
description: 'DELTAMODE: The time constant for delayed reactive power seen by
the VSI droop controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
VSI_Rfilter:
name: VSI_Rfilter
annotations:
order:
tag: order
value: 100
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: VSI_Rfilter[pu]
description: VSI filter resistance (p.u.)
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: pu
VSI_Xfilter:
name: VSI_Xfilter
annotations:
order:
tag: order
value: 101
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: VSI_Xfilter[pu]
description: VSI filter inductance (p.u.)
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: pu
VSI_mode:
name: VSI_mode
annotations:
order:
tag: order
value: 102
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: VSI_mode
description: 'VSI MODEL: Selects VSI mode for either isochronous or droop one'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
VSI_freq:
name: VSI_freq
annotations:
order:
tag: order
value: 103
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VSI_freq
description: VSI frequency
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
ki_Vterminal:
name: ki_Vterminal
annotations:
order:
tag: order
value: 104
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: ki_Vterminal
description: 'DELTAMODE: The integrator gain for the VSI terminal voltage modulation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
kp_Vterminal:
name: kp_Vterminal
annotations:
order:
tag: order
value: 105
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kp_Vterminal
description: 'DELTAMODE: The proportional gain for the VSI terminal voltage modulation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
V_set_droop:
name: V_set_droop
annotations:
order:
tag: order
value: 106
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_set_droop
description: 'DELTAMODE: The voltage setpoint of droop control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
V_set0:
name: V_set0
annotations:
order:
tag: order
value: 107
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_set0
description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
V_set1:
name: V_set1
annotations:
order:
tag: order
value: 108
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_set1
description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
V_set2:
name: V_set2
annotations:
order:
tag: order
value: 109
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_set2
description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
enable_ramp_rates_real:
name: enable_ramp_rates_real
annotations:
order:
tag: order
value: 110
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: enable_ramp_rates_real
description: 'DELTAMODE: Boolean used to indicate whether inverter ramp rate is
enforced or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
max_ramp_up_real:
name: max_ramp_up_real
annotations:
order:
tag: order
value: 111
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_ramp_up_real[W/s]
description: 'DELTAMODE: The real power ramp up rate limit'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W/s
max_ramp_down_real:
name: max_ramp_down_real
annotations:
order:
tag: order
value: 112
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_ramp_down_real[W/s]
description: 'DELTAMODE: The real power ramp down rate limit'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W/s
enable_ramp_rates_reactive:
name: enable_ramp_rates_reactive
annotations:
order:
tag: order
value: 113
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: enable_ramp_rates_reactive
description: 'DELTAMODE: Boolean used to indicate whether inverter ramp rate is
enforced or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
max_ramp_up_reactive:
name: max_ramp_up_reactive
annotations:
order:
tag: order
value: 114
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_ramp_up_reactive[VAr/s]
description: 'DELTAMODE: The reactive power ramp up rate limit'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: VAr/s
max_ramp_down_reactive:
name: max_ramp_down_reactive
annotations:
order:
tag: order
value: 115
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_ramp_down_reactive[VAr/s]
description: 'DELTAMODE: The reactive power ramp down rate limit'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: VAr/s
dynamic_model_mode:
name: dynamic_model_mode
annotations:
order:
tag: order
value: 116
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: dynamic_model_mode
description: 'DELTAMODE: Underlying model to use for deltamode control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
enable_1547_checks:
name: enable_1547_checks
annotations:
order:
tag: order
value: 117
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: enable_1547_checks
description: 'DELTAMODE: Enable IEEE 1547-2003 disconnect checking'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: boolean
required: false
reconnect_time:
name: reconnect_time
annotations:
order:
tag: order
value: 118
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: reconnect_time[s]
description: 'DELTAMODE: Time delay after IEEE 1547-2003 violation clears before
resuming generation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- motor
- performance_motor
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
inverter_1547_status:
name: inverter_1547_status
annotations:
order:
tag: order
value: 119
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: inverter_1547_status
description: 'DELTAMODE: Indicator if the inverter is curtailed due to a 1547
violation or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: boolean
required: false
IEEE_1547_version:
name: IEEE_1547_version
annotations:
order:
tag: order
value: 120
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: IEEE_1547_version
description: 'DELTAMODE: Version of IEEE 1547 to use to populate defaults'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: Ieee1547Version
required: false
over_freq_high_cutout:
name: over_freq_high_cutout
annotations:
order:
tag: order
value: 121
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_high_cutout[Hz]
description: 'DELTAMODE: OF2 set point for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: Hz
over_freq_high_disconnect_time:
name: over_freq_high_disconnect_time
annotations:
order:
tag: order
value: 122
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_high_disconnect_time[s]
description: 'DELTAMODE: OF2 clearing time for IEEE1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
over_freq_low_cutout:
name: over_freq_low_cutout
annotations:
order:
tag: order
value: 123
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_low_cutout[Hz]
description: 'DELTAMODE: OF1 set point for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: Hz
over_freq_low_disconnect_time:
name: over_freq_low_disconnect_time
annotations:
order:
tag: order
value: 124
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_low_disconnect_time[s]
description: 'DELTAMODE: OF1 clearing time for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_freq_high_cutout:
name: under_freq_high_cutout
annotations:
order:
tag: order
value: 125
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_high_cutout[Hz]
description: 'DELTAMODE: UF2 set point for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: Hz
under_freq_high_disconnect_time:
name: under_freq_high_disconnect_time
annotations:
order:
tag: order
value: 126
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_high_disconnect_time[s]
description: 'DELTAMODE: UF2 clearing time for IEEE1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_freq_low_cutout:
name: under_freq_low_cutout
annotations:
order:
tag: order
value: 127
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_low_cutout[Hz]
description: 'DELTAMODE: UF1 set point for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: Hz
under_freq_low_disconnect_time:
name: under_freq_low_disconnect_time
annotations:
order:
tag: order
value: 128
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_low_disconnect_time[s]
description: 'DELTAMODE: UF1 clearing time for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_voltage_low_cutout:
name: under_voltage_low_cutout
annotations:
order:
tag: order
value: 129
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_low_cutout[pu]
description: Lowest voltage threshold for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
under_voltage_middle_cutout:
name: under_voltage_middle_cutout
annotations:
order:
tag: order
value: 130
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_middle_cutout[pu]
description: Middle-lowest voltage threshold for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
under_voltage_high_cutout:
name: under_voltage_high_cutout
annotations:
order:
tag: order
value: 131
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_high_cutout[pu]
description: High value of low voltage threshold for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
over_voltage_low_cutout:
name: over_voltage_low_cutout
annotations:
order:
tag: order
value: 132
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_low_cutout[pu]
description: Lowest voltage value for overvoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
over_voltage_high_cutout:
name: over_voltage_high_cutout
annotations:
order:
tag: order
value: 133
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_high_cutout[pu]
description: High voltage value for overvoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
under_voltage_low_disconnect_time:
name: under_voltage_low_disconnect_time
annotations:
order:
tag: order
value: 134
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_low_disconnect_time[s]
description: Lowest voltage clearing time for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_voltage_middle_disconnect_time:
name: under_voltage_middle_disconnect_time
annotations:
order:
tag: order
value: 135
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_middle_disconnect_time[s]
description: Middle-lowest voltage clearing time for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_voltage_high_disconnect_time:
name: under_voltage_high_disconnect_time
annotations:
order:
tag: order
value: 136
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_high_disconnect_time[s]
description: Highest voltage clearing time for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
over_voltage_low_disconnect_time:
name: over_voltage_low_disconnect_time
annotations:
order:
tag: order
value: 137
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_low_disconnect_time[s]
description: Lowest voltage clearing time for overvoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
over_voltage_high_disconnect_time:
name: over_voltage_high_disconnect_time
annotations:
order:
tag: order
value: 138
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_high_disconnect_time[s]
description: Highest voltage clearing time for overvoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
IEEE_1547_trip_method:
name: IEEE_1547_trip_method
annotations:
order:
tag: order
value: 139
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: IEEE_1547_trip_method
description: High over-voltage level trip
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- inverter_dyn
range: Ieee1547TripMethod
required: false
phases:
name: phases
annotations:
order:
tag: order
value: 140
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: phases
description: The phases the inverter is attached to
comments:
- 'Import: A, B, C is wye to neutral (phases blank on three); S is s1s2 D across
the legs at 240 V. Export: the letters then N; a split-phase bus''s letter then
S.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
related_mappings:
- cim:Terminal.phases
- cim:PowerElectronicsConnection.phaseConnection
domain_of:
- powerflow_object
- inverter
- rectifier
- windturb_dg
range: string
required: false
use_multipoint_efficiency:
name: use_multipoint_efficiency
annotations:
order:
tag: order
value: 141
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: use_multipoint_efficiency
description: 'FOUR QUADRANT MODEL: boolean to used the multipoint efficiency curve
for the inverter when solar is attached'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
inverter_manufacturer:
name: inverter_manufacturer
annotations:
order:
tag: order
value: 142
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: inverter_manufacturer
description: 'MULTIPOINT EFFICIENCY MODEL: the manufacturer of the inverter to
setup up pre-existing efficiency curves'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
maximum_dc_power:
name: maximum_dc_power
annotations:
order:
tag: order
value: 143
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: maximum_dc_power
description: 'MULTIPOINT EFFICIENCY MODEL: the maximum dc power point for the
efficiency curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
maximum_dc_voltage:
name: maximum_dc_voltage
annotations:
order:
tag: order
value: 144
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: maximum_dc_voltage
description: 'MULTIPOINT EFFICIENCY MODEL: the maximum dc voltage point for the
efficiency curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
minimum_dc_power:
name: minimum_dc_power
annotations:
order:
tag: order
value: 145
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: minimum_dc_power
description: 'MULTIPOINT EFFICIENCY MODEL: the minimum dc power point for the
efficiency curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
c_0:
name: c_0
annotations:
order:
tag: order
value: 146
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: c_0
description: 'MULTIPOINT EFFICIENCY MODEL: the first coefficient in the efficiency
curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
c_1:
name: c_1
annotations:
order:
tag: order
value: 147
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: c_1
description: 'MULTIPOINT EFFICIENCY MODEL: the second coefficient in the efficiency
curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
c_2:
name: c_2
annotations:
order:
tag: order
value: 148
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: c_2
description: 'MULTIPOINT EFFICIENCY MODEL: the third coefficient in the efficiency
curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
c_3:
name: c_3
annotations:
order:
tag: order
value: 149
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: c_3
description: 'MULTIPOINT EFFICIENCY MODEL: the fourth coefficient in the efficiency
curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
sense_object:
name: sense_object
annotations:
order:
tag: order
value: 150
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: sense_object
description: 'FOUR QUADRANT MODEL: name of the object the inverter is trying to
mitigate the load on (node/link) in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
max_charge_rate:
name: max_charge_rate
annotations:
order:
tag: order
value: 151
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_charge_rate[W]
description: 'FOUR QUADRANT MODEL: maximum rate the battery can be charged in
LOAD_FOLLOWING'
comments:
- 'Import: StorageInverterInfo.chargeRateActiveMax (W), a nameplate GridLAB-D
reads only in load following. Export: chargeRateActiveMax x the unit''s share.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
exact_mappings:
- cim:StorageInverterInfo.chargeRateActiveMax
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
max_discharge_rate:
name: max_discharge_rate
annotations:
order:
tag: order
value: 152
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_discharge_rate[W]
description: 'FOUR QUADRANT MODEL: maximum rate the battery can be discharged
in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
charge_on_threshold:
name: charge_on_threshold
annotations:
order:
tag: order
value: 153
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: charge_on_threshold[W]
description: 'FOUR QUADRANT MODEL: power level at which the inverter should try
charging the battery in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
charge_off_threshold:
name: charge_off_threshold
annotations:
order:
tag: order
value: 154
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: charge_off_threshold[W]
description: 'FOUR QUADRANT MODEL: power level at which the inverter should cease
charging the battery in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
discharge_on_threshold:
name: discharge_on_threshold
annotations:
order:
tag: order
value: 155
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: discharge_on_threshold[W]
description: 'FOUR QUADRANT MODEL: power level at which the inverter should try
discharging the battery in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
discharge_off_threshold:
name: discharge_off_threshold
annotations:
order:
tag: order
value: 156
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: discharge_off_threshold[W]
description: 'FOUR QUADRANT MODEL: power level at which the inverter should cease
discharging the battery in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
excess_input_power:
name: excess_input_power
annotations:
order:
tag: order
value: 157
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: excess_input_power[W]
description: 'FOUR QUADRANT MODEL: Excess power at the input of the inverter that
is otherwise just lost, or could be shunted to a battery'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
charge_lockout_time:
name: charge_lockout_time
annotations:
order:
tag: order
value: 158
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: charge_lockout_time[s]
description: 'FOUR QUADRANT MODEL: Lockout time when a charging operation occurs
before another LOAD_FOLLOWING dispatch operation can occur'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
discharge_lockout_time:
name: discharge_lockout_time
annotations:
order:
tag: order
value: 159
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: discharge_lockout_time[s]
description: 'FOUR QUADRANT MODEL: Lockout time when a discharging operation occurs
before another LOAD_FOLLOWING dispatch operation can occur'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
pf_reg_activate:
name: pf_reg_activate
annotations:
order:
tag: order
value: 160
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_activate
description: 'FOUR QUADRANT MODEL: Lowest acceptable power-factor level below
which power-factor regulation will activate.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pf_reg_deactivate:
name: pf_reg_deactivate
annotations:
order:
tag: order
value: 161
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_deactivate
description: 'FOUR QUADRANT MODEL: Lowest acceptable power-factor above which
no power-factor regulation is needed.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pf_target:
name: pf_target
annotations:
order:
tag: order
value: 162
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_target
description: 'FOUR QUADRANT MODEL: Desired power-factor to maintain (signed) positive
is inductive'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pf_reg_high:
name: pf_reg_high
annotations:
order:
tag: order
value: 163
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_high
description: 'FOUR QUADRANT MODEL: Upper limit for power-factor - if exceeds,
go full reverse reactive'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pf_reg_low:
name: pf_reg_low
annotations:
order:
tag: order
value: 164
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_low
description: 'FOUR QUADRANT MODEL: Lower limit for power-factor - if exceeds,
stop regulating - pf_target_var is below this'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pf_reg_activate_lockout_time:
name: pf_reg_activate_lockout_time
annotations:
order:
tag: order
value: 165
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_activate_lockout_time[s]
description: 'FOUR QUADRANT MODEL: Mandatory pause between the deactivation of
power-factor regulation and it reactivation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
disable_volt_var_if_no_input_power:
name: disable_volt_var_if_no_input_power
annotations:
order:
tag: order
value: 166
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: disable_volt_var_if_no_input_power
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
delay_time:
name: delay_time
annotations:
order:
tag: order
value: 167
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delay_time[s]
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
max_var_slew_rate:
name: max_var_slew_rate
annotations:
order:
tag: order
value: 168
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_var_slew_rate[VAr/s]
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: VAr/s
max_pwr_slew_rate:
name: max_pwr_slew_rate
annotations:
order:
tag: order
value: 169
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_pwr_slew_rate[W/s]
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W/s
volt_var_sched:
name: volt_var_sched
annotations:
order:
tag: order
value: 170
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: volt_var_sched
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
freq_pwr_sched:
name: freq_pwr_sched
annotations:
order:
tag: order
value: 171
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: freq_pwr_sched
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
charge_threshold:
name: charge_threshold
annotations:
order:
tag: order
value: 172
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: charge_threshold[W]
description: 'FOUR QUADRANT MODEL: Level at which all inverters in the group will
begin charging attached batteries. Regulated minimum load level.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
discharge_threshold:
name: discharge_threshold
annotations:
order:
tag: order
value: 173
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: discharge_threshold[W]
description: 'FOUR QUADRANT MODEL: Level at which all inverters in the group will
begin discharging attached batteries. Regulated maximum load level.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
group_max_charge_rate:
name: group_max_charge_rate
annotations:
order:
tag: order
value: 174
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: group_max_charge_rate[W]
description: 'FOUR QUADRANT MODEL: Sum of the charge rates of the batteries involved
in the group load-following.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
group_max_discharge_rate:
name: group_max_discharge_rate
annotations:
order:
tag: order
value: 175
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: group_max_discharge_rate[W]
description: 'FOUR QUADRANT MODEL: Sum of the discharge rates of the batteries
involved in the group load-following.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
group_rated_power:
name: group_rated_power
annotations:
order:
tag: order
value: 176
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: group_rated_power[W]
description: 'FOUR QUADRANT MODEL: Sum of the inverter power ratings of the inverters
involved in the group power-factor regulation.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
V_base:
name: V_base
annotations:
order:
tag: order
value: 177
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_base[V]
description: 'FOUR QUADRANT MODEL: The base voltage on the grid side of the inverter.
Used in VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: V
V1:
name: V1
annotations:
order:
tag: order
value: 178
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V1[pu]
description: 'FOUR QUADRANT MODEL: voltage point 1 in volt/var curve. Used in
VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
Q1:
name: Q1
annotations:
order:
tag: order
value: 179
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q1[pu]
description: 'FOUR QUADRANT MODEL: VAR point 1 in volt/var curve. Used in VOLT_VAR
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
V2:
name: V2
annotations:
order:
tag: order
value: 180
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V2[pu]
description: 'FOUR QUADRANT MODEL: voltage point 2 in volt/var curve. Used in
VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
Q2:
name: Q2
annotations:
order:
tag: order
value: 181
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q2[pu]
description: 'FOUR QUADRANT MODEL: VAR point 2 in volt/var curve. Used in VOLT_VAR
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
V3:
name: V3
annotations:
order:
tag: order
value: 182
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V3[pu]
description: 'FOUR QUADRANT MODEL: voltage point 3 in volt/var curve. Used in
VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
Q3:
name: Q3
annotations:
order:
tag: order
value: 183
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q3[pu]
description: 'FOUR QUADRANT MODEL: VAR point 3 in volt/var curve. Used in VOLT_VAR
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
V4:
name: V4
annotations:
order:
tag: order
value: 184
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V4[pu]
description: 'FOUR QUADRANT MODEL: voltage point 4 in volt/var curve. Used in
VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
Q4:
name: Q4
annotations:
order:
tag: order
value: 185
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q4[pu]
description: 'FOUR QUADRANT MODEL: VAR point 4 in volt/var curve. Used in VOLT_VAR
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
volt_var_control_lockout:
name: volt_var_control_lockout
annotations:
order:
tag: order
value: 186
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: volt_var_control_lockout[s]
description: 'FOUR QUADRANT QUADRANT MODEL: the lockout time between volt/var
actions.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
number_of_phases_out:
name: number_of_phases_out
annotations:
order:
tag: order
value: 187
value_type:
tag: value_type
value: int
native_name:
tag: native_name
value: number_of_phases_out
description: Exposed variable - hidden for solar
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: integer
required: false
efficiency_value:
name: efficiency_value
annotations:
order:
tag: order
value: 188
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: efficiency_value
description: Exposed variable - hidden for solar
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
VW_V1:
name: VW_V1
annotations:
order:
tag: order
value: 189
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VW_V1[pu]
description: 'FOUR QUADRANT MODEL: Voltage at which power limiting begins (e.g.
1.0583). Used in VOLT_WATT control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
VW_V2:
name: VW_V2
annotations:
order:
tag: order
value: 190
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VW_V2[pu]
description: 'FOUR QUADRANT MODEL: Voltage at which power limiting ends. (e.g.
1.1000). Used in VOLT_WATT control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
VW_P1:
name: VW_P1
annotations:
order:
tag: order
value: 191
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VW_P1[pu]
description: 'FOUR QUADRANT MODEL: Power limit at VW_P1 (e.g. 1). Used in VOLT_WATT
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
VW_P2:
name: VW_P2
annotations:
order:
tag: order
value: 192
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VW_P2[pu]
description: 'FOUR QUADRANT MODEL: Power limit at VW_P2 (e.g. 0). Used in VOLT_WATT
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
WT_is_connected:
name: WT_is_connected
annotations:
order:
tag: order
value: 193
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: WT_is_connected
description: Internal flag that indicates a wind turbine child is connected
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
pf_reg_status:
name: pf_reg_status
annotations:
order:
tag: order
value: 194
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: pf_reg_status
description: 'CHECKPOINT_VAR: internal variable for pf_reg_status'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
load_follow_status:
name: load_follow_status
annotations:
order:
tag: order
value: 195
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: load_follow_status
description: 'CHECKPOINT_VAR: Status variable for what the load_following mode
is doing'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
last_current_A:
name: last_current_A
annotations:
order:
tag: order
value: 196
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_current_A
description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
from parent so XML files look proper) - element 0'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_current_B:
name: last_current_B
annotations:
order:
tag: order
value: 197
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_current_B
description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
from parent so XML files look proper) - element 1'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_current_C:
name: last_current_C
annotations:
order:
tag: order
value: 198
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_current_C
description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
from parent so XML files look proper) - element 2'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_current_D:
name: last_current_D
annotations:
order:
tag: order
value: 199
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_current_D
description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
from parent so XML files look proper) - element 3'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_power_A:
name: last_power_A
annotations:
order:
tag: order
value: 200
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_power_A
description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
- used to remove from parent so XML looks right - element 0'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_power_B:
name: last_power_B
annotations:
order:
tag: order
value: 201
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_power_B
description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
- used to remove from parent so XML looks right - element 1'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_power_C:
name: last_power_C
annotations:
order:
tag: order
value: 202
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_power_C
description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
- used to remove from parent so XML looks right - element 2'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_power_D:
name: last_power_D
annotations:
order:
tag: order
value: 203
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_power_D
description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
- used to remove from parent so XML looks right - element 3'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
inverter_first_step:
name: inverter_first_step
annotations:
order:
tag: order
value: 204
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: inverter_first_step
description: 'CHECKPOINT_VAR: internal variable for inverter_first_step'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
first_iteration_current_injection:
name: first_iteration_current_injection
annotations:
order:
tag: order
value: 205
value_type:
tag: value_type
value: int
native_name:
tag: native_name
value: first_iteration_current_injection
description: 'CHECKPOINT_VAR: Initialization variable - mostly so SWING_PQ buses
initalize properly for deltamode'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: integer
required: false
m12:
name: m12
annotations:
order:
tag: order
value: 206
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: m12
description: 'CHECKPOINT_VAR: internal variable for m12'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
b12:
name: b12
annotations:
order:
tag: order
value: 207
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: b12
description: 'CHECKPOINT_VAR: internal variable for b12'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
m23:
name: m23
annotations:
order:
tag: order
value: 208
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: m23
description: 'CHECKPOINT_VAR: internal variable for m23'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
b23:
name: b23
annotations:
order:
tag: order
value: 209
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: b23
description: 'CHECKPOINT_VAR: internal variable for b23'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
m34:
name: m34
annotations:
order:
tag: order
value: 210
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: m34
description: 'CHECKPOINT_VAR: internal variable for m34'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
b34:
name: b34
annotations:
order:
tag: order
value: 211
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: b34
description: 'CHECKPOINT_VAR: internal variable for b34'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
allowed_vv_action:
name: allowed_vv_action
annotations:
order:
tag: order
value: 212
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: allowed_vv_action
description: 'CHECKPOINT_VAR: internal variable for allowed_vv_action'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
last_vv_check:
name: last_vv_check
annotations:
order:
tag: order
value: 213
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: last_vv_check
description: 'CHECKPOINT_VAR: internal variable for last_vv_check'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
IEEE_1547_STATUS:
name: IEEE_1547_STATUS
annotations:
order:
tag: order
value: 214
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: IEEE_1547_STATUS
description: 'CHECKPOINT_VAR: internal variable for ieee_1547_version'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
over_freq_high_band_viol_time:
name: over_freq_high_band_viol_time
annotations:
order:
tag: order
value: 215
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_high_band_viol_time
description: 'CHECKPOINT_VAR: OF2 violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
over_freq_low_band_viol_time:
name: over_freq_low_band_viol_time
annotations:
order:
tag: order
value: 216
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_low_band_viol_time
description: 'CHECKPOINT_VAR: OF1 violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
under_freq_low_band_viol_time:
name: under_freq_low_band_viol_time
annotations:
order:
tag: order
value: 217
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_low_band_viol_time
description: 'CHECKPOINT_VAR: UF1 violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
under_voltage_lowest_viol_time:
name: under_voltage_lowest_viol_time
annotations:
order:
tag: order
value: 218
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_lowest_viol_time
description: 'CHECKPOINT_VAR: Lowest low voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
under_voltage_middle_viol_time:
name: under_voltage_middle_viol_time
annotations:
order:
tag: order
value: 219
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_middle_viol_time
description: 'CHECKPOINT_VAR: Middle low voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
under_voltage_high_viol_time:
name: under_voltage_high_viol_time
annotations:
order:
tag: order
value: 220
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_high_viol_time
description: 'CHECKPOINT_VAR: Highest low voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
over_voltage_low_viol_time:
name: over_voltage_low_viol_time
annotations:
order:
tag: order
value: 221
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_low_viol_time
description: 'CHECKPOINT_VAR: Lowest high voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
over_voltage_high_viol_time:
name: over_voltage_high_viol_time
annotations:
order:
tag: order
value: 222
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_high_viol_time
description: 'CHECKPOINT_VAR: Highest high voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
lf_dispatch_power:
name: lf_dispatch_power
annotations:
order:
tag: order
value: 223
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: lf_dispatch_power
description: 'CHECKPOINT_VAR: Amount of real power to try and dispatch to meet
thresholds'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
next_update_time:
name: next_update_time
annotations:
order:
tag: order
value: 224
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: next_update_time
description: 'CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
lf_dispatch_change_allowed:
name: lf_dispatch_change_allowed
annotations:
order:
tag: order
value: 225
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: lf_dispatch_change_allowed
description: 'CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
pf_reg_dispatch_change_allowed:
name: pf_reg_dispatch_change_allowed
annotations:
order:
tag: order
value: 226
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: pf_reg_dispatch_change_allowed
description: 'CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed
for power factor regulation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
pf_reg_dispatch_VAR:
name: pf_reg_dispatch_VAR
annotations:
order:
tag: order
value: 227
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_dispatch_VAR
description: 'CHECKPOINT_VAR: (Reactive only?) power dispatched to meet power
factor regulation threshold'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pf_reg_next_update_time:
name: pf_reg_next_update_time
annotations:
order:
tag: order
value: 228
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: pf_reg_next_update_time
description: 'CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
prev_time:
name: prev_time
annotations:
order:
tag: order
value: 229
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: prev_time
description: 'CHECKPOINT_VAR: Tracking variable for previous "new time" run'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- battery
- inverter
range: string
required: false
prev_time_dbl:
name: prev_time_dbl
annotations:
order:
tag: order
value: 230
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: prev_time_dbl
description: 'CHECKPOINT_VAR: Tracking variable for 1547 checks and ramp rates'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- evcharger_det
range: float
required: false
event_deltat:
name: event_deltat
annotations:
order:
tag: order
value: 231
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: event_deltat
description: 'CHECKPOINT_VAR: Event-driven delta-t variable'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
start_time:
name: start_time
annotations:
order:
tag: order
value: 232
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: start_time
description: 'CHECKPOINT_VAR: Recording start time of simulation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
- dryer
- refrigerator
range: string
required: false
last_I_Out_A:
name: last_I_Out_A
annotations:
order:
tag: order
value: 233
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_I_Out_A
description: 'CHECKPOINT_VAR: internal variable for last_I_Out[0]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_I_Out_B:
name: last_I_Out_B
annotations:
order:
tag: order
value: 234
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_I_Out_B
description: 'CHECKPOINT_VAR: internal variable for last_I_Out[1]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_I_Out_C:
name: last_I_Out_C
annotations:
order:
tag: order
value: 235
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_I_Out_C
description: 'CHECKPOINT_VAR: internal variable for last_I_Out[2]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
last_I_In:
name: last_I_In
annotations:
order:
tag: order
value: 236
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: last_I_In
description: 'CHECKPOINT_VAR: internal variable for last_I_In'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pa_vw_limited:
name: pa_vw_limited
annotations:
order:
tag: order
value: 237
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pa_vw_limited
description: 'CHECKPOINT_VAR: internal variable for pa_vw_limited'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pb_vw_limited:
name: pb_vw_limited
annotations:
order:
tag: order
value: 238
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pb_vw_limited
description: 'CHECKPOINT_VAR: internal variable for pb_vw_limited'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
pc_vw_limited:
name: pc_vw_limited
annotations:
order:
tag: order
value: 239
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pc_vw_limited
description: 'CHECKPOINT_VAR: internal variable for pc_vw_limited'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
out_of_violation_time_total:
name: out_of_violation_time_total
annotations:
order:
tag: order
value: 240
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: out_of_violation_time_total
description: 'CHECKPOINT_VAR: internal variable for out_of_violation_time_total'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: float
required: false
deltamode_inclusive:
name: deltamode_inclusive
annotations:
order:
tag: order
value: 241
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: deltamode_inclusive
description: 'CHECKPOINT_VAR: Boolean for deltamode calls - pulled from object
flags'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
first_sync_delta_enabled:
name: first_sync_delta_enabled
annotations:
order:
tag: order
value: 242
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: first_sync_delta_enabled
description: 'CHECKPOINT_VAR: internal variable for first_sync_delta_enabled'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: boolean
required: false
first_iter_counter:
name: first_iter_counter
annotations:
order:
tag: order
value: 243
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: first_iter_counter
description: 'CHECKPOINT_VAR: internal variable for first_iter_counter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: string
required: false
first_run:
name: first_run
annotations:
order:
tag: order
value: 244
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: first_run
description: 'CHECKPOINT_VAR: internal variable for first_run'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
domain_of:
- controller_dg
- inverter
range: boolean
required: false
prev_value_IGenerated_A:
name: prev_value_IGenerated_A
annotations:
order:
tag: order
value: 245
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_value_IGenerated_A
description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[0]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
prev_value_IGenerated_B:
name: prev_value_IGenerated_B
annotations:
order:
tag: order
value: 246
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_value_IGenerated_B
description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[1]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
prev_value_IGenerated_C:
name: prev_value_IGenerated_C
annotations:
order:
tag: order
value: 247
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_value_IGenerated_C
description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[2]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
domain_of:
- inverter
range: Complex
required: false
Induced¶
name: inverter
description: 'Copyright (C) 2008 Battelle Memorial Institute
@file inverter.cpp
@defgroup inverter
@ingroup generators
@{
Inherits from: gld_object
Type: Instance (network topology element)
Note: Inherits from gld_object (not in generators module)'
comments:
- 'Import: PowerElectronicsConnection, mRID pv_ or storage_ + name by its solar or
battery child (inverter.cimtbl), with a GenerationInverterInfo or StorageInverterInfo
datasheet; one child is mapped, GridLAB-D has no delta inverter. Export: each PowerElectronicsConnection,
one inverter per unit (name_<n> when several), parented to its bus.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:PowerElectronicsConnection
close_mappings:
- cim:GenerationInverterInfo
- cim:StorageInverterInfo
is_a: glm_object
attributes:
inverter_type:
name: inverter_type
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: inverter_type
description: 'LEGACY MODEL: Sets efficiencies and other parameters; if using four_quadrant_control_mode,
set this to FOUR_QUADRANT'
comments:
- 'Import: structural; FOUR_QUADRANT only, any other raises (unset is GridLAB-D''s
PWM). Export: FOUR_QUADRANT.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
four_quadrant_control_mode:
name: four_quadrant_control_mode
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: four_quadrant_control_mode
description: 'FOUR QUADRANT MODEL: Activates various control modes'
comments:
- 'Import: structural; CONSTANT_PF on a solar, CONSTANT_PQ on a battery (which
also reads CONSTANT_PF), others raise; the mode''s capability flag goes in the
row comment, InverterCapabilities is not written yet. Export: CONSTANT_PQ on
a battery, CONSTANT_PF on a PV.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
pf_reg:
name: pf_reg
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: pf_reg
description: Activate (or not) power factor regulation in four_quadrant_control_mode
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
generator_status:
name: generator_status
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: generator_status
description: describes whether the generator is online or offline
comments:
- 'Import: ONLINE (default) is normallyInService true, OFFLINE false and the output
0. Export: OFFLINE when normallyInService is false, else ONLINE.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:Equipment.normallyInService
owner: inverter
domain_of:
- battery
- inverter
range: string
required: false
generator_mode:
name: generator_mode
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: generator_mode
description: 'LEGACY MODEL: Selects generator control mode when using legacy model;
in non-legacy models, this should be SUPPLY_DRIVEN.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- battery
- inverter
- rectifier
range: GeneratorMode
required: false
inverter_convergence_criterion:
name: inverter_convergence_criterion
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: inverter_convergence_criterion
description: The maximum change in error threshold for exitting deltamode.
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
current_convergence:
name: current_convergence
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: current_convergence[A]
description: Convergence criterion for current changes on first timestep - basically
initialization of system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- diesel_dg
- inverter
range: float
required: false
unit:
ucum_code: A
V_In:
name: V_In
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_In[V]
description: DC voltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: V
I_In:
name: I_In
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: I_In[A]
description: DC current
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- battery
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: A
P_In:
name: P_In
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: P_In[W]
description: DC power
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: W
VA_Out:
name: VA_Out
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: VA_Out[VA]
description: AC power
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- battery
- inverter
- inverter_dyn
- rectifier
range: Complex
required: false
unit:
ucum_code: VA
Vdc:
name: Vdc
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Vdc[V]
description: 'LEGACY MODEL: DC voltage'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: V
phaseA_V_Out:
name: phaseA_V_Out
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseA_V_Out[V]
description: AC voltage on A phase in three-phase system; 240-V connection on
a triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: V
phaseB_V_Out:
name: phaseB_V_Out
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseB_V_Out[V]
description: AC voltage on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: V
phaseC_V_Out:
name: phaseC_V_Out
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseC_V_Out[V]
description: AC voltage on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: V
phaseA_I_Out:
name: phaseA_I_Out
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseA_I_Out[V]
description: AC current on A phase in three-phase system; 240-V connection on
a triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: Complex
required: false
unit:
ucum_code: V
phaseB_I_Out:
name: phaseB_I_Out
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseB_I_Out[V]
description: AC current on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: Complex
required: false
unit:
ucum_code: V
phaseC_I_Out:
name: phaseC_I_Out
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseC_I_Out[V]
description: AC current on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: Complex
required: false
unit:
ucum_code: V
power_A:
name: power_A
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_A[VA]
description: AC power on A phase in three-phase system; 240-V connection on a
triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_B:
name: power_B
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_B[VA]
description: AC power on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
power_C:
name: power_C
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: power_C[VA]
description: AC power on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- node
- inverter
- inverter_dyn
- windturb_dg
range: Complex
required: false
unit:
ucum_code: VA
curr_VA_out_A:
name: curr_VA_out_A
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: curr_VA_out_A[VA]
description: AC power on A phase in three-phase system; 240-V connection on a
triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
curr_VA_out_B:
name: curr_VA_out_B
annotations:
order:
tag: order
value: 23
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: curr_VA_out_B[VA]
description: AC power on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
curr_VA_out_C:
name: curr_VA_out_C
annotations:
order:
tag: order
value: 24
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: curr_VA_out_C[VA]
description: AC power on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
prev_VA_out_A:
name: prev_VA_out_A
annotations:
order:
tag: order
value: 25
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_VA_out_A[VA]
description: AC power on A phase in three-phase system; 240-V connection on a
triplex system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
prev_VA_out_B:
name: prev_VA_out_B
annotations:
order:
tag: order
value: 26
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_VA_out_B[VA]
description: AC power on B phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
prev_VA_out_C:
name: prev_VA_out_C
annotations:
order:
tag: order
value: 27
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_VA_out_C[VA]
description: AC power on C phase in three-phase system
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: VA
e_source_A:
name: e_source_A
annotations:
order:
tag: order
value: 28
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: e_source_A
description: 'DELTAMODE: Internal voltage of grid-forming source, phase A'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
e_source_B:
name: e_source_B
annotations:
order:
tag: order
value: 29
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: e_source_B
description: 'DELTAMODE: Internal voltage of grid-forming source, phase B'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
e_source_C:
name: e_source_C
annotations:
order:
tag: order
value: 30
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: e_source_C
description: 'DELTAMODE: Internal voltage of grid-forming source, phase C'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
V_angle_A:
name: V_angle_A
annotations:
order:
tag: order
value: 31
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_angle_A
description: 'DELTAMODE: Internal angle of grid-forming source, phase A'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
V_angle_B:
name: V_angle_B
annotations:
order:
tag: order
value: 32
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_angle_B
description: 'DELTAMODE: Internal angle of grid-forming source, phase B'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
V_angle_C:
name: V_angle_C
annotations:
order:
tag: order
value: 33
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_angle_C
description: 'DELTAMODE: Internal angle of grid-forming source, phase C'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
phaseA_I_Forming:
name: phaseA_I_Forming
annotations:
order:
tag: order
value: 34
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseA_I_Forming[A]
description: AC current on A phase in three-phase system, only for grid_forming
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseB_I_Forming:
name: phaseB_I_Forming
annotations:
order:
tag: order
value: 35
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseB_I_Forming[A]
description: AC current on B phase in three-phase system, only for grid_forming
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseC_I_Forming:
name: phaseC_I_Forming
annotations:
order:
tag: order
value: 36
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseC_I_Forming[A]
description: AC current on C phase in three-phase system, only for grid_forming
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseA_I_Following:
name: phaseA_I_Following
annotations:
order:
tag: order
value: 37
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseA_I_Following[A]
description: AC current on A phase in three-phase system, only for grid_following
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseB_I_Following:
name: phaseB_I_Following
annotations:
order:
tag: order
value: 38
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseB_I_Following[A]
description: AC current on B phase in three-phase system, only for grid_following
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
phaseC_I_Following:
name: phaseC_I_Following
annotations:
order:
tag: order
value: 39
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: phaseC_I_Following[A]
description: AC current on C phase in three-phase system, only for grid_following
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: A
pCircuit_V_Avg:
name: pCircuit_V_Avg
annotations:
order:
tag: order
value: 40
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pCircuit_V_Avg
description: 'DELTAMODE: three-phase average value of terminal voltage'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
P_Out:
name: P_Out
annotations:
order:
tag: order
value: 41
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: P_Out[VA]
description: 'FOUR QUADRANT MODEL: Scheduled real power out in CONSTANT_PQ control
mode'
comments:
- 'Import: a battery''s CONSTANT_PQ set point, limited by ratedS, a full battery
or the reserve, is p (W, load sign) and gives batteryState; a PV''s is an output
GridLAB-D overwrites, so only in the row comment. Export: a battery''s p from
get_inverter_units, generation sign.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.p
- cim:BatteryUnit.batteryState
rank: 1000
owner: inverter
domain_of:
- inverter
- solar
range: float
required: false
unit:
ucum_code: VA
Q_Out:
name: Q_Out
annotations:
order:
tag: order
value: 42
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q_Out[VAr]
description: 'FOUR QUADRANT MODEL: Schedule reactive power out in CONSTANT_PQ
control mode'
comments:
- 'Import: q (VAr) is 0 when unset or 0; any other value raises. Export: a battery''s
q, generation sign.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.q
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: VAr
power_in:
name: power_in
annotations:
order:
tag: order
value: 43
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: power_in[W]
description: 'LEGACY MODEL: No longer used'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- link
- inverter
range: float
required: false
unit:
ucum_code: W
rated_power:
name: rated_power
annotations:
order:
tag: order
value: 44
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: rated_power[VA]
description: 'FOUR QUADRANT MODEL: The rated power of the inverter'
comments:
- 'Import: ratedS (VA) = rated_power x the phases out (3, 2, 1; S is 1); maxQ
= -minQ = ratedS, and the datasheet''s apparentPowerMaximum; unset or 0 raises.
Export: ratedS x the unit''s share / phases.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.ratedS
- cim:PowerElectronicsConnection.maxQ
- cim:PowerElectronicsConnection.minQ
- cim:GridEdgeDeviceInfo.apparentPowerMaximum
owner: inverter
domain_of:
- battery
- inverter
- inverter_dyn
- solar
range: float
required: false
unit:
ucum_code: VA
rated_battery_power:
name: rated_battery_power
annotations:
order:
tag: order
value: 45
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: rated_battery_power[W]
description: 'FOUR QUADRANT MODEL: The rated power of battery when battery is
attached'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
inverter_efficiency:
name: inverter_efficiency
annotations:
order:
tag: order
value: 46
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: inverter_efficiency
description: 'FOUR QUADRANT MODEL: The efficiency of the inverter'
comments:
- 'Import: PV AC = DC x inverter_efficiency (default 0.9) is folded into p; CIM
has no inverter efficiency. Export: 1 on a PV; the losses are in p.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.p
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
battery_soc:
name: battery_soc
annotations:
order:
tag: order
value: 47
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: battery_soc[pu]
description: 'FOUR QUADRANT MODEL: The state of charge of an attached battery'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
soc_reserve:
name: soc_reserve
annotations:
order:
tag: order
value: 48
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: soc_reserve[pu]
description: 'FOUR QUADRANT MODEL: The reserve state of charge of an attached
battery for islanding cases'
comments:
- 'Import: BatteryUnit.minimumE (Wh) = soc_reserve x battery_capacity; default
0. Export: minimumE / ratedE.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:BatteryUnit.minimumE
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
power_factor:
name: power_factor
annotations:
order:
tag: order
value: 49
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: power_factor[unit]
description: 'FOUR QUADRANT MODEL: The power factor used for CONSTANT_PF control
mode'
comments:
- 'Import: CONSTANT_PF q is 0 when |pf| is 1; |pf| < 1 raises. Export: a PV''s
p / |p + jq|, negative when q is.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
close_mappings:
- cim:PowerElectronicsConnection.q
owner: inverter
domain_of:
- performance_motor
- battery
- inverter
- windturb_dg
- residential_enduse
range: float
required: false
unit:
ucum_code: unit
islanded_state:
name: islanded_state
annotations:
order:
tag: order
value: 50
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: islanded_state
description: 'FOUR QUADRANT MODEL: Boolean used to let control modes to act under
island conditions'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
nominal_frequency:
name: nominal_frequency
annotations:
order:
tag: order
value: 51
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: nominal_frequency[Hz]
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: Hz
Pref:
name: Pref
annotations:
order:
tag: order
value: 52
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pref
description: 'DELTAMODE: The real power reference.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- diesel_dg
- inverter
- inverter_dyn
range: float
required: false
Qref:
name: Qref
annotations:
order:
tag: order
value: 53
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Qref
description: 'DELTAMODE: The reactive power reference.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- diesel_dg
- inverter
- inverter_dyn
range: float
required: false
kpd:
name: kpd
annotations:
order:
tag: order
value: 54
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kpd
description: 'DELTAMODE: The d-axis integration gain for the current modulation
PI controller.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
kpq:
name: kpq
annotations:
order:
tag: order
value: 55
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kpq
description: 'DELTAMODE: The q-axis integration gain for the current modulation
PI controller.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
kid:
name: kid
annotations:
order:
tag: order
value: 56
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kid
description: 'DELTAMODE: The d-axis proportional gain for the current modulation
PI controller.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
kiq:
name: kiq
annotations:
order:
tag: order
value: 57
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kiq
description: 'DELTAMODE: The q-axis proportional gain for the current modulation
PI controller.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
kdd:
name: kdd
annotations:
order:
tag: order
value: 58
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kdd
description: 'DELTAMODE: The d-axis differentiator gain for the current modulation
PID controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
kdq:
name: kdq
annotations:
order:
tag: order
value: 59
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kdq
description: 'DELTAMODE: The q-axis differentiator gain for the current modulation
PID controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
epA:
name: epA
annotations:
order:
tag: order
value: 60
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: epA
description: 'DELTAMODE: The real current error for phase A or triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
epB:
name: epB
annotations:
order:
tag: order
value: 61
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: epB
description: 'DELTAMODE: The real current error for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
epC:
name: epC
annotations:
order:
tag: order
value: 62
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: epC
description: 'DELTAMODE: The real current error for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
eqA:
name: eqA
annotations:
order:
tag: order
value: 63
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: eqA
description: 'DELTAMODE: The reactive current error for phase A or triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
eqB:
name: eqB
annotations:
order:
tag: order
value: 64
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: eqB
description: 'DELTAMODE: The reactive current error for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
eqC:
name: eqC
annotations:
order:
tag: order
value: 65
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: eqC
description: 'DELTAMODE: The reactive current error for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_epA:
name: delta_epA
annotations:
order:
tag: order
value: 66
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_epA
description: 'DELTAMODE: The change in real current error for phase A or triplex
phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_epB:
name: delta_epB
annotations:
order:
tag: order
value: 67
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_epB
description: 'DELTAMODE: The change in real current error for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_epC:
name: delta_epC
annotations:
order:
tag: order
value: 68
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_epC
description: 'DELTAMODE: The change in real current error for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_eqA:
name: delta_eqA
annotations:
order:
tag: order
value: 69
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_eqA
description: 'DELTAMODE: The change in reactive current error for phase A or triplex
phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_eqB:
name: delta_eqB
annotations:
order:
tag: order
value: 70
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_eqB
description: 'DELTAMODE: The change in reactive current error for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_eqC:
name: delta_eqC
annotations:
order:
tag: order
value: 71
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_eqC
description: 'DELTAMODE: The change in reactive current error for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
mdA:
name: mdA
annotations:
order:
tag: order
value: 72
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mdA
description: 'DELTAMODE: The d-axis current modulation for phase A or triplex
phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
mdB:
name: mdB
annotations:
order:
tag: order
value: 73
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mdB
description: 'DELTAMODE: The d-axis current modulation for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
mdC:
name: mdC
annotations:
order:
tag: order
value: 74
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mdC
description: 'DELTAMODE: The d-axis current modulation for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
mqA:
name: mqA
annotations:
order:
tag: order
value: 75
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mqA
description: 'DELTAMODE: The q-axis current modulation for phase A or triplex
phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
mqB:
name: mqB
annotations:
order:
tag: order
value: 76
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mqB
description: 'DELTAMODE: The q-axis current modulation for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
mqC:
name: mqC
annotations:
order:
tag: order
value: 77
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: mqC
description: 'DELTAMODE: The q-axis current modulation for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_mdA:
name: delta_mdA
annotations:
order:
tag: order
value: 78
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mdA
description: 'DELTAMODE: The change in d-axis current modulation for phase A or
triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_mdB:
name: delta_mdB
annotations:
order:
tag: order
value: 79
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mdB
description: 'DELTAMODE: The change in d-axis current modulation for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_mdC:
name: delta_mdC
annotations:
order:
tag: order
value: 80
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mdC
description: 'DELTAMODE: The change in d-axis current modulation for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_mqA:
name: delta_mqA
annotations:
order:
tag: order
value: 81
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mqA
description: 'DELTAMODE: The change in q-axis current modulation for phase A or
triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_mqB:
name: delta_mqB
annotations:
order:
tag: order
value: 82
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mqB
description: 'DELTAMODE: The change in q-axis current modulation for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
delta_mqC:
name: delta_mqC
annotations:
order:
tag: order
value: 83
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delta_mqC
description: 'DELTAMODE: The change in q-axis current modulation for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
IdqA:
name: IdqA
annotations:
order:
tag: order
value: 84
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: IdqA
description: 'DELTAMODE: The dq-axis current for phase A or triplex phase.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
IdqB:
name: IdqB
annotations:
order:
tag: order
value: 85
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: IdqB
description: 'DELTAMODE: The dq-axis current for phase B.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
IdqC:
name: IdqC
annotations:
order:
tag: order
value: 86
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: IdqC
description: 'DELTAMODE: The dq-axis current for phase C.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
Tfreq_delay:
name: Tfreq_delay
annotations:
order:
tag: order
value: 87
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tfreq_delay
description: 'DELTAMODE: The time constant for delayed frequency seen by the inverter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
inverter_droop_fp:
name: inverter_droop_fp
annotations:
order:
tag: order
value: 88
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: inverter_droop_fp
description: 'DELTAMODE: Boolean used to indicate whether inverter f/p droop is
included or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
R_fp:
name: R_fp
annotations:
order:
tag: order
value: 89
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_fp
description: 'DELTAMODE: The droop parameter of the f/p droop'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
kppmax:
name: kppmax
annotations:
order:
tag: order
value: 90
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kppmax
description: 'DELTAMODE: The proportional gain of Pmax controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
kipmax:
name: kipmax
annotations:
order:
tag: order
value: 91
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kipmax
description: 'DELTAMODE: The integral gain of Pmax controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
Pmax:
name: Pmax
annotations:
order:
tag: order
value: 92
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pmax
description: 'DELTAMODE: power limit of grid forming inverter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
Pmin:
name: Pmin
annotations:
order:
tag: order
value: 93
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pmin
description: 'DELTAMODE: power limit of grid forming inverter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
Pmax_Low_Limit:
name: Pmax_Low_Limit
annotations:
order:
tag: order
value: 94
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Pmax_Low_Limit
description: 'DELTAMODE: output limit of Pmax controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
Tvol_delay:
name: Tvol_delay
annotations:
order:
tag: order
value: 95
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tvol_delay
description: 'DELTAMODE: The time constant for delayed voltage seen by the inverter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
inverter_droop_vq:
name: inverter_droop_vq
annotations:
order:
tag: order
value: 96
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: inverter_droop_vq
description: 'DELTAMODE: Boolean used to indicate whether inverter q/v droop is
included or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
R_vq:
name: R_vq
annotations:
order:
tag: order
value: 97
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: R_vq
description: 'DELTAMODE: The droop parameter of the v/q droop'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
Tp_delay:
name: Tp_delay
annotations:
order:
tag: order
value: 98
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tp_delay
description: 'DELTAMODE: The time constant for delayed real power seen by the
VSI droop controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
Tq_delay:
name: Tq_delay
annotations:
order:
tag: order
value: 99
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Tq_delay
description: 'DELTAMODE: The time constant for delayed reactive power seen by
the VSI droop controller'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
VSI_Rfilter:
name: VSI_Rfilter
annotations:
order:
tag: order
value: 100
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: VSI_Rfilter[pu]
description: VSI filter resistance (p.u.)
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: pu
VSI_Xfilter:
name: VSI_Xfilter
annotations:
order:
tag: order
value: 101
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: VSI_Xfilter[pu]
description: VSI filter inductance (p.u.)
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
unit:
ucum_code: pu
VSI_mode:
name: VSI_mode
annotations:
order:
tag: order
value: 102
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: VSI_mode
description: 'VSI MODEL: Selects VSI mode for either isochronous or droop one'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
VSI_freq:
name: VSI_freq
annotations:
order:
tag: order
value: 103
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VSI_freq
description: VSI frequency
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
ki_Vterminal:
name: ki_Vterminal
annotations:
order:
tag: order
value: 104
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: ki_Vterminal
description: 'DELTAMODE: The integrator gain for the VSI terminal voltage modulation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
kp_Vterminal:
name: kp_Vterminal
annotations:
order:
tag: order
value: 105
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: kp_Vterminal
description: 'DELTAMODE: The proportional gain for the VSI terminal voltage modulation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
V_set_droop:
name: V_set_droop
annotations:
order:
tag: order
value: 106
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_set_droop
description: 'DELTAMODE: The voltage setpoint of droop control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
V_set0:
name: V_set0
annotations:
order:
tag: order
value: 107
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_set0
description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
V_set1:
name: V_set1
annotations:
order:
tag: order
value: 108
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_set1
description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
V_set2:
name: V_set2
annotations:
order:
tag: order
value: 109
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_set2
description: 'DELTAMODE: The voltage setpoint of grid-following Q-V droop control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
enable_ramp_rates_real:
name: enable_ramp_rates_real
annotations:
order:
tag: order
value: 110
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: enable_ramp_rates_real
description: 'DELTAMODE: Boolean used to indicate whether inverter ramp rate is
enforced or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
max_ramp_up_real:
name: max_ramp_up_real
annotations:
order:
tag: order
value: 111
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_ramp_up_real[W/s]
description: 'DELTAMODE: The real power ramp up rate limit'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W/s
max_ramp_down_real:
name: max_ramp_down_real
annotations:
order:
tag: order
value: 112
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_ramp_down_real[W/s]
description: 'DELTAMODE: The real power ramp down rate limit'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W/s
enable_ramp_rates_reactive:
name: enable_ramp_rates_reactive
annotations:
order:
tag: order
value: 113
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: enable_ramp_rates_reactive
description: 'DELTAMODE: Boolean used to indicate whether inverter ramp rate is
enforced or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
max_ramp_up_reactive:
name: max_ramp_up_reactive
annotations:
order:
tag: order
value: 114
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_ramp_up_reactive[VAr/s]
description: 'DELTAMODE: The reactive power ramp up rate limit'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: VAr/s
max_ramp_down_reactive:
name: max_ramp_down_reactive
annotations:
order:
tag: order
value: 115
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_ramp_down_reactive[VAr/s]
description: 'DELTAMODE: The reactive power ramp down rate limit'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: VAr/s
dynamic_model_mode:
name: dynamic_model_mode
annotations:
order:
tag: order
value: 116
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: dynamic_model_mode
description: 'DELTAMODE: Underlying model to use for deltamode control'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
enable_1547_checks:
name: enable_1547_checks
annotations:
order:
tag: order
value: 117
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: enable_1547_checks
description: 'DELTAMODE: Enable IEEE 1547-2003 disconnect checking'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: boolean
required: false
reconnect_time:
name: reconnect_time
annotations:
order:
tag: order
value: 118
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: reconnect_time[s]
description: 'DELTAMODE: Time delay after IEEE 1547-2003 violation clears before
resuming generation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- motor
- performance_motor
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
inverter_1547_status:
name: inverter_1547_status
annotations:
order:
tag: order
value: 119
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: inverter_1547_status
description: 'DELTAMODE: Indicator if the inverter is curtailed due to a 1547
violation or not'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: boolean
required: false
IEEE_1547_version:
name: IEEE_1547_version
annotations:
order:
tag: order
value: 120
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: IEEE_1547_version
description: 'DELTAMODE: Version of IEEE 1547 to use to populate defaults'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: Ieee1547Version
required: false
over_freq_high_cutout:
name: over_freq_high_cutout
annotations:
order:
tag: order
value: 121
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_high_cutout[Hz]
description: 'DELTAMODE: OF2 set point for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: Hz
over_freq_high_disconnect_time:
name: over_freq_high_disconnect_time
annotations:
order:
tag: order
value: 122
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_high_disconnect_time[s]
description: 'DELTAMODE: OF2 clearing time for IEEE1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
over_freq_low_cutout:
name: over_freq_low_cutout
annotations:
order:
tag: order
value: 123
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_low_cutout[Hz]
description: 'DELTAMODE: OF1 set point for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: Hz
over_freq_low_disconnect_time:
name: over_freq_low_disconnect_time
annotations:
order:
tag: order
value: 124
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_low_disconnect_time[s]
description: 'DELTAMODE: OF1 clearing time for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_freq_high_cutout:
name: under_freq_high_cutout
annotations:
order:
tag: order
value: 125
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_high_cutout[Hz]
description: 'DELTAMODE: UF2 set point for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: Hz
under_freq_high_disconnect_time:
name: under_freq_high_disconnect_time
annotations:
order:
tag: order
value: 126
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_high_disconnect_time[s]
description: 'DELTAMODE: UF2 clearing time for IEEE1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_freq_low_cutout:
name: under_freq_low_cutout
annotations:
order:
tag: order
value: 127
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_low_cutout[Hz]
description: 'DELTAMODE: UF1 set point for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: Hz
under_freq_low_disconnect_time:
name: under_freq_low_disconnect_time
annotations:
order:
tag: order
value: 128
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_low_disconnect_time[s]
description: 'DELTAMODE: UF1 clearing time for IEEE 1547a'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_voltage_low_cutout:
name: under_voltage_low_cutout
annotations:
order:
tag: order
value: 129
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_low_cutout[pu]
description: Lowest voltage threshold for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
under_voltage_middle_cutout:
name: under_voltage_middle_cutout
annotations:
order:
tag: order
value: 130
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_middle_cutout[pu]
description: Middle-lowest voltage threshold for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
under_voltage_high_cutout:
name: under_voltage_high_cutout
annotations:
order:
tag: order
value: 131
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_high_cutout[pu]
description: High value of low voltage threshold for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
over_voltage_low_cutout:
name: over_voltage_low_cutout
annotations:
order:
tag: order
value: 132
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_low_cutout[pu]
description: Lowest voltage value for overvoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
over_voltage_high_cutout:
name: over_voltage_high_cutout
annotations:
order:
tag: order
value: 133
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_high_cutout[pu]
description: High voltage value for overvoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: pu
under_voltage_low_disconnect_time:
name: under_voltage_low_disconnect_time
annotations:
order:
tag: order
value: 134
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_low_disconnect_time[s]
description: Lowest voltage clearing time for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_voltage_middle_disconnect_time:
name: under_voltage_middle_disconnect_time
annotations:
order:
tag: order
value: 135
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_middle_disconnect_time[s]
description: Middle-lowest voltage clearing time for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
under_voltage_high_disconnect_time:
name: under_voltage_high_disconnect_time
annotations:
order:
tag: order
value: 136
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_high_disconnect_time[s]
description: Highest voltage clearing time for undervoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
over_voltage_low_disconnect_time:
name: over_voltage_low_disconnect_time
annotations:
order:
tag: order
value: 137
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_low_disconnect_time[s]
description: Lowest voltage clearing time for overvoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
over_voltage_high_disconnect_time:
name: over_voltage_high_disconnect_time
annotations:
order:
tag: order
value: 138
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_high_disconnect_time[s]
description: Highest voltage clearing time for overvoltage
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: float
required: false
unit:
ucum_code: s
IEEE_1547_trip_method:
name: IEEE_1547_trip_method
annotations:
order:
tag: order
value: 139
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: IEEE_1547_trip_method
description: High over-voltage level trip
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- inverter_dyn
range: Ieee1547TripMethod
required: false
phases:
name: phases
annotations:
order:
tag: order
value: 140
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: phases
description: The phases the inverter is attached to
comments:
- 'Import: A, B, C is wye to neutral (phases blank on three); S is s1s2 D across
the legs at 240 V. Export: the letters then N; a split-phase bus''s letter then
S.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
related_mappings:
- cim:Terminal.phases
- cim:PowerElectronicsConnection.phaseConnection
owner: inverter
domain_of:
- powerflow_object
- inverter
- rectifier
- windturb_dg
range: string
required: false
use_multipoint_efficiency:
name: use_multipoint_efficiency
annotations:
order:
tag: order
value: 141
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: use_multipoint_efficiency
description: 'FOUR QUADRANT MODEL: boolean to used the multipoint efficiency curve
for the inverter when solar is attached'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
inverter_manufacturer:
name: inverter_manufacturer
annotations:
order:
tag: order
value: 142
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: inverter_manufacturer
description: 'MULTIPOINT EFFICIENCY MODEL: the manufacturer of the inverter to
setup up pre-existing efficiency curves'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
maximum_dc_power:
name: maximum_dc_power
annotations:
order:
tag: order
value: 143
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: maximum_dc_power
description: 'MULTIPOINT EFFICIENCY MODEL: the maximum dc power point for the
efficiency curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
maximum_dc_voltage:
name: maximum_dc_voltage
annotations:
order:
tag: order
value: 144
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: maximum_dc_voltage
description: 'MULTIPOINT EFFICIENCY MODEL: the maximum dc voltage point for the
efficiency curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
minimum_dc_power:
name: minimum_dc_power
annotations:
order:
tag: order
value: 145
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: minimum_dc_power
description: 'MULTIPOINT EFFICIENCY MODEL: the minimum dc power point for the
efficiency curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
c_0:
name: c_0
annotations:
order:
tag: order
value: 146
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: c_0
description: 'MULTIPOINT EFFICIENCY MODEL: the first coefficient in the efficiency
curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
c_1:
name: c_1
annotations:
order:
tag: order
value: 147
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: c_1
description: 'MULTIPOINT EFFICIENCY MODEL: the second coefficient in the efficiency
curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
c_2:
name: c_2
annotations:
order:
tag: order
value: 148
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: c_2
description: 'MULTIPOINT EFFICIENCY MODEL: the third coefficient in the efficiency
curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
c_3:
name: c_3
annotations:
order:
tag: order
value: 149
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: c_3
description: 'MULTIPOINT EFFICIENCY MODEL: the fourth coefficient in the efficiency
curve'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
sense_object:
name: sense_object
annotations:
order:
tag: order
value: 150
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: sense_object
description: 'FOUR QUADRANT MODEL: name of the object the inverter is trying to
mitigate the load on (node/link) in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
max_charge_rate:
name: max_charge_rate
annotations:
order:
tag: order
value: 151
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_charge_rate[W]
description: 'FOUR QUADRANT MODEL: maximum rate the battery can be charged in
LOAD_FOLLOWING'
comments:
- 'Import: StorageInverterInfo.chargeRateActiveMax (W), a nameplate GridLAB-D
reads only in load following. Export: chargeRateActiveMax x the unit''s share.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
exact_mappings:
- cim:StorageInverterInfo.chargeRateActiveMax
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
max_discharge_rate:
name: max_discharge_rate
annotations:
order:
tag: order
value: 152
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_discharge_rate[W]
description: 'FOUR QUADRANT MODEL: maximum rate the battery can be discharged
in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
charge_on_threshold:
name: charge_on_threshold
annotations:
order:
tag: order
value: 153
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: charge_on_threshold[W]
description: 'FOUR QUADRANT MODEL: power level at which the inverter should try
charging the battery in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
charge_off_threshold:
name: charge_off_threshold
annotations:
order:
tag: order
value: 154
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: charge_off_threshold[W]
description: 'FOUR QUADRANT MODEL: power level at which the inverter should cease
charging the battery in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
discharge_on_threshold:
name: discharge_on_threshold
annotations:
order:
tag: order
value: 155
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: discharge_on_threshold[W]
description: 'FOUR QUADRANT MODEL: power level at which the inverter should try
discharging the battery in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
discharge_off_threshold:
name: discharge_off_threshold
annotations:
order:
tag: order
value: 156
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: discharge_off_threshold[W]
description: 'FOUR QUADRANT MODEL: power level at which the inverter should cease
discharging the battery in LOAD_FOLLOWING'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
excess_input_power:
name: excess_input_power
annotations:
order:
tag: order
value: 157
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: excess_input_power[W]
description: 'FOUR QUADRANT MODEL: Excess power at the input of the inverter that
is otherwise just lost, or could be shunted to a battery'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
charge_lockout_time:
name: charge_lockout_time
annotations:
order:
tag: order
value: 158
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: charge_lockout_time[s]
description: 'FOUR QUADRANT MODEL: Lockout time when a charging operation occurs
before another LOAD_FOLLOWING dispatch operation can occur'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
discharge_lockout_time:
name: discharge_lockout_time
annotations:
order:
tag: order
value: 159
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: discharge_lockout_time[s]
description: 'FOUR QUADRANT MODEL: Lockout time when a discharging operation occurs
before another LOAD_FOLLOWING dispatch operation can occur'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
pf_reg_activate:
name: pf_reg_activate
annotations:
order:
tag: order
value: 160
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_activate
description: 'FOUR QUADRANT MODEL: Lowest acceptable power-factor level below
which power-factor regulation will activate.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pf_reg_deactivate:
name: pf_reg_deactivate
annotations:
order:
tag: order
value: 161
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_deactivate
description: 'FOUR QUADRANT MODEL: Lowest acceptable power-factor above which
no power-factor regulation is needed.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pf_target:
name: pf_target
annotations:
order:
tag: order
value: 162
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_target
description: 'FOUR QUADRANT MODEL: Desired power-factor to maintain (signed) positive
is inductive'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pf_reg_high:
name: pf_reg_high
annotations:
order:
tag: order
value: 163
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_high
description: 'FOUR QUADRANT MODEL: Upper limit for power-factor - if exceeds,
go full reverse reactive'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pf_reg_low:
name: pf_reg_low
annotations:
order:
tag: order
value: 164
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_low
description: 'FOUR QUADRANT MODEL: Lower limit for power-factor - if exceeds,
stop regulating - pf_target_var is below this'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pf_reg_activate_lockout_time:
name: pf_reg_activate_lockout_time
annotations:
order:
tag: order
value: 165
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_activate_lockout_time[s]
description: 'FOUR QUADRANT MODEL: Mandatory pause between the deactivation of
power-factor regulation and it reactivation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
disable_volt_var_if_no_input_power:
name: disable_volt_var_if_no_input_power
annotations:
order:
tag: order
value: 166
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: disable_volt_var_if_no_input_power
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
delay_time:
name: delay_time
annotations:
order:
tag: order
value: 167
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: delay_time[s]
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
max_var_slew_rate:
name: max_var_slew_rate
annotations:
order:
tag: order
value: 168
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_var_slew_rate[VAr/s]
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: VAr/s
max_pwr_slew_rate:
name: max_pwr_slew_rate
annotations:
order:
tag: order
value: 169
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: max_pwr_slew_rate[W/s]
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W/s
volt_var_sched:
name: volt_var_sched
annotations:
order:
tag: order
value: 170
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: volt_var_sched
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
freq_pwr_sched:
name: freq_pwr_sched
annotations:
order:
tag: order
value: 171
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: freq_pwr_sched
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
charge_threshold:
name: charge_threshold
annotations:
order:
tag: order
value: 172
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: charge_threshold[W]
description: 'FOUR QUADRANT MODEL: Level at which all inverters in the group will
begin charging attached batteries. Regulated minimum load level.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
discharge_threshold:
name: discharge_threshold
annotations:
order:
tag: order
value: 173
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: discharge_threshold[W]
description: 'FOUR QUADRANT MODEL: Level at which all inverters in the group will
begin discharging attached batteries. Regulated maximum load level.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
group_max_charge_rate:
name: group_max_charge_rate
annotations:
order:
tag: order
value: 174
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: group_max_charge_rate[W]
description: 'FOUR QUADRANT MODEL: Sum of the charge rates of the batteries involved
in the group load-following.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
group_max_discharge_rate:
name: group_max_discharge_rate
annotations:
order:
tag: order
value: 175
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: group_max_discharge_rate[W]
description: 'FOUR QUADRANT MODEL: Sum of the discharge rates of the batteries
involved in the group load-following.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
group_rated_power:
name: group_rated_power
annotations:
order:
tag: order
value: 176
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: group_rated_power[W]
description: 'FOUR QUADRANT MODEL: Sum of the inverter power ratings of the inverters
involved in the group power-factor regulation.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: W
V_base:
name: V_base
annotations:
order:
tag: order
value: 177
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V_base[V]
description: 'FOUR QUADRANT MODEL: The base voltage on the grid side of the inverter.
Used in VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: V
V1:
name: V1
annotations:
order:
tag: order
value: 178
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V1[pu]
description: 'FOUR QUADRANT MODEL: voltage point 1 in volt/var curve. Used in
VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
Q1:
name: Q1
annotations:
order:
tag: order
value: 179
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q1[pu]
description: 'FOUR QUADRANT MODEL: VAR point 1 in volt/var curve. Used in VOLT_VAR
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
V2:
name: V2
annotations:
order:
tag: order
value: 180
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V2[pu]
description: 'FOUR QUADRANT MODEL: voltage point 2 in volt/var curve. Used in
VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
Q2:
name: Q2
annotations:
order:
tag: order
value: 181
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q2[pu]
description: 'FOUR QUADRANT MODEL: VAR point 2 in volt/var curve. Used in VOLT_VAR
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
V3:
name: V3
annotations:
order:
tag: order
value: 182
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V3[pu]
description: 'FOUR QUADRANT MODEL: voltage point 3 in volt/var curve. Used in
VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
Q3:
name: Q3
annotations:
order:
tag: order
value: 183
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q3[pu]
description: 'FOUR QUADRANT MODEL: VAR point 3 in volt/var curve. Used in VOLT_VAR
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
V4:
name: V4
annotations:
order:
tag: order
value: 184
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: V4[pu]
description: 'FOUR QUADRANT MODEL: voltage point 4 in volt/var curve. Used in
VOLT_VAR control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
Q4:
name: Q4
annotations:
order:
tag: order
value: 185
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: Q4[pu]
description: 'FOUR QUADRANT MODEL: VAR point 4 in volt/var curve. Used in VOLT_VAR
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
volt_var_control_lockout:
name: volt_var_control_lockout
annotations:
order:
tag: order
value: 186
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: volt_var_control_lockout[s]
description: 'FOUR QUADRANT QUADRANT MODEL: the lockout time between volt/var
actions.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: s
number_of_phases_out:
name: number_of_phases_out
annotations:
order:
tag: order
value: 187
value_type:
tag: value_type
value: int
native_name:
tag: native_name
value: number_of_phases_out
description: Exposed variable - hidden for solar
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: integer
required: false
efficiency_value:
name: efficiency_value
annotations:
order:
tag: order
value: 188
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: efficiency_value
description: Exposed variable - hidden for solar
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
VW_V1:
name: VW_V1
annotations:
order:
tag: order
value: 189
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VW_V1[pu]
description: 'FOUR QUADRANT MODEL: Voltage at which power limiting begins (e.g.
1.0583). Used in VOLT_WATT control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
VW_V2:
name: VW_V2
annotations:
order:
tag: order
value: 190
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VW_V2[pu]
description: 'FOUR QUADRANT MODEL: Voltage at which power limiting ends. (e.g.
1.1000). Used in VOLT_WATT control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
VW_P1:
name: VW_P1
annotations:
order:
tag: order
value: 191
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VW_P1[pu]
description: 'FOUR QUADRANT MODEL: Power limit at VW_P1 (e.g. 1). Used in VOLT_WATT
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
VW_P2:
name: VW_P2
annotations:
order:
tag: order
value: 192
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: VW_P2[pu]
description: 'FOUR QUADRANT MODEL: Power limit at VW_P2 (e.g. 0). Used in VOLT_WATT
control mode.'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
unit:
ucum_code: pu
WT_is_connected:
name: WT_is_connected
annotations:
order:
tag: order
value: 193
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: WT_is_connected
description: Internal flag that indicates a wind turbine child is connected
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
pf_reg_status:
name: pf_reg_status
annotations:
order:
tag: order
value: 194
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: pf_reg_status
description: 'CHECKPOINT_VAR: internal variable for pf_reg_status'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
load_follow_status:
name: load_follow_status
annotations:
order:
tag: order
value: 195
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: load_follow_status
description: 'CHECKPOINT_VAR: Status variable for what the load_following mode
is doing'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
last_current_A:
name: last_current_A
annotations:
order:
tag: order
value: 196
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_current_A
description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
from parent so XML files look proper) - element 0'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_current_B:
name: last_current_B
annotations:
order:
tag: order
value: 197
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_current_B
description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
from parent so XML files look proper) - element 1'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_current_C:
name: last_current_C
annotations:
order:
tag: order
value: 198
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_current_C
description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
from parent so XML files look proper) - element 2'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_current_D:
name: last_current_D
annotations:
order:
tag: order
value: 199
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_current_D
description: 'CHECKPOINT_VAR: Previously applied power output (used to remove
from parent so XML files look proper) - element 3'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_power_A:
name: last_power_A
annotations:
order:
tag: order
value: 200
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_power_A
description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
- used to remove from parent so XML looks right - element 0'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_power_B:
name: last_power_B
annotations:
order:
tag: order
value: 201
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_power_B
description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
- used to remove from parent so XML looks right - element 1'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_power_C:
name: last_power_C
annotations:
order:
tag: order
value: 202
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_power_C
description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
- used to remove from parent so XML looks right - element 2'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_power_D:
name: last_power_D
annotations:
order:
tag: order
value: 203
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_power_D
description: 'CHECKPOINT_VAR: Previously applied power output (as constant power)
- used to remove from parent so XML looks right - element 3'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
inverter_first_step:
name: inverter_first_step
annotations:
order:
tag: order
value: 204
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: inverter_first_step
description: 'CHECKPOINT_VAR: internal variable for inverter_first_step'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
first_iteration_current_injection:
name: first_iteration_current_injection
annotations:
order:
tag: order
value: 205
value_type:
tag: value_type
value: int
native_name:
tag: native_name
value: first_iteration_current_injection
description: 'CHECKPOINT_VAR: Initialization variable - mostly so SWING_PQ buses
initalize properly for deltamode'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: integer
required: false
m12:
name: m12
annotations:
order:
tag: order
value: 206
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: m12
description: 'CHECKPOINT_VAR: internal variable for m12'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
b12:
name: b12
annotations:
order:
tag: order
value: 207
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: b12
description: 'CHECKPOINT_VAR: internal variable for b12'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
m23:
name: m23
annotations:
order:
tag: order
value: 208
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: m23
description: 'CHECKPOINT_VAR: internal variable for m23'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
b23:
name: b23
annotations:
order:
tag: order
value: 209
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: b23
description: 'CHECKPOINT_VAR: internal variable for b23'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
m34:
name: m34
annotations:
order:
tag: order
value: 210
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: m34
description: 'CHECKPOINT_VAR: internal variable for m34'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
b34:
name: b34
annotations:
order:
tag: order
value: 211
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: b34
description: 'CHECKPOINT_VAR: internal variable for b34'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
allowed_vv_action:
name: allowed_vv_action
annotations:
order:
tag: order
value: 212
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: allowed_vv_action
description: 'CHECKPOINT_VAR: internal variable for allowed_vv_action'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
last_vv_check:
name: last_vv_check
annotations:
order:
tag: order
value: 213
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: last_vv_check
description: 'CHECKPOINT_VAR: internal variable for last_vv_check'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
IEEE_1547_STATUS:
name: IEEE_1547_STATUS
annotations:
order:
tag: order
value: 214
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: IEEE_1547_STATUS
description: 'CHECKPOINT_VAR: internal variable for ieee_1547_version'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
over_freq_high_band_viol_time:
name: over_freq_high_band_viol_time
annotations:
order:
tag: order
value: 215
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_high_band_viol_time
description: 'CHECKPOINT_VAR: OF2 violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
over_freq_low_band_viol_time:
name: over_freq_low_band_viol_time
annotations:
order:
tag: order
value: 216
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_freq_low_band_viol_time
description: 'CHECKPOINT_VAR: OF1 violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
under_freq_low_band_viol_time:
name: under_freq_low_band_viol_time
annotations:
order:
tag: order
value: 217
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_freq_low_band_viol_time
description: 'CHECKPOINT_VAR: UF1 violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
under_voltage_lowest_viol_time:
name: under_voltage_lowest_viol_time
annotations:
order:
tag: order
value: 218
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_lowest_viol_time
description: 'CHECKPOINT_VAR: Lowest low voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
under_voltage_middle_viol_time:
name: under_voltage_middle_viol_time
annotations:
order:
tag: order
value: 219
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_middle_viol_time
description: 'CHECKPOINT_VAR: Middle low voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
under_voltage_high_viol_time:
name: under_voltage_high_viol_time
annotations:
order:
tag: order
value: 220
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: under_voltage_high_viol_time
description: 'CHECKPOINT_VAR: Highest low voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
over_voltage_low_viol_time:
name: over_voltage_low_viol_time
annotations:
order:
tag: order
value: 221
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_low_viol_time
description: 'CHECKPOINT_VAR: Lowest high voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
over_voltage_high_viol_time:
name: over_voltage_high_viol_time
annotations:
order:
tag: order
value: 222
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: over_voltage_high_viol_time
description: 'CHECKPOINT_VAR: Highest high voltage threshold violation accumulator'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
lf_dispatch_power:
name: lf_dispatch_power
annotations:
order:
tag: order
value: 223
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: lf_dispatch_power
description: 'CHECKPOINT_VAR: Amount of real power to try and dispatch to meet
thresholds'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
next_update_time:
name: next_update_time
annotations:
order:
tag: order
value: 224
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: next_update_time
description: 'CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
lf_dispatch_change_allowed:
name: lf_dispatch_change_allowed
annotations:
order:
tag: order
value: 225
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: lf_dispatch_change_allowed
description: 'CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
pf_reg_dispatch_change_allowed:
name: pf_reg_dispatch_change_allowed
annotations:
order:
tag: order
value: 226
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: pf_reg_dispatch_change_allowed
description: 'CHECKPOINT_VAR: Flag to indicate if a change in dispatch is allowed
for power factor regulation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
pf_reg_dispatch_VAR:
name: pf_reg_dispatch_VAR
annotations:
order:
tag: order
value: 227
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pf_reg_dispatch_VAR
description: 'CHECKPOINT_VAR: (Reactive only?) power dispatched to meet power
factor regulation threshold'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pf_reg_next_update_time:
name: pf_reg_next_update_time
annotations:
order:
tag: order
value: 228
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: pf_reg_next_update_time
description: 'CHECKPOINT_VAR: TIMESTAMP of next dispatching change allowed'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
prev_time:
name: prev_time
annotations:
order:
tag: order
value: 229
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: prev_time
description: 'CHECKPOINT_VAR: Tracking variable for previous "new time" run'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- battery
- inverter
range: string
required: false
prev_time_dbl:
name: prev_time_dbl
annotations:
order:
tag: order
value: 230
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: prev_time_dbl
description: 'CHECKPOINT_VAR: Tracking variable for 1547 checks and ramp rates'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- evcharger_det
range: float
required: false
event_deltat:
name: event_deltat
annotations:
order:
tag: order
value: 231
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: event_deltat
description: 'CHECKPOINT_VAR: Event-driven delta-t variable'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
start_time:
name: start_time
annotations:
order:
tag: order
value: 232
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: start_time
description: 'CHECKPOINT_VAR: Recording start time of simulation'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
- dryer
- refrigerator
range: string
required: false
last_I_Out_A:
name: last_I_Out_A
annotations:
order:
tag: order
value: 233
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_I_Out_A
description: 'CHECKPOINT_VAR: internal variable for last_I_Out[0]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_I_Out_B:
name: last_I_Out_B
annotations:
order:
tag: order
value: 234
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_I_Out_B
description: 'CHECKPOINT_VAR: internal variable for last_I_Out[1]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_I_Out_C:
name: last_I_Out_C
annotations:
order:
tag: order
value: 235
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: last_I_Out_C
description: 'CHECKPOINT_VAR: internal variable for last_I_Out[2]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
last_I_In:
name: last_I_In
annotations:
order:
tag: order
value: 236
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: last_I_In
description: 'CHECKPOINT_VAR: internal variable for last_I_In'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pa_vw_limited:
name: pa_vw_limited
annotations:
order:
tag: order
value: 237
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pa_vw_limited
description: 'CHECKPOINT_VAR: internal variable for pa_vw_limited'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pb_vw_limited:
name: pb_vw_limited
annotations:
order:
tag: order
value: 238
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pb_vw_limited
description: 'CHECKPOINT_VAR: internal variable for pb_vw_limited'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
pc_vw_limited:
name: pc_vw_limited
annotations:
order:
tag: order
value: 239
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: pc_vw_limited
description: 'CHECKPOINT_VAR: internal variable for pc_vw_limited'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
out_of_violation_time_total:
name: out_of_violation_time_total
annotations:
order:
tag: order
value: 240
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: out_of_violation_time_total
description: 'CHECKPOINT_VAR: internal variable for out_of_violation_time_total'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: float
required: false
deltamode_inclusive:
name: deltamode_inclusive
annotations:
order:
tag: order
value: 241
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: deltamode_inclusive
description: 'CHECKPOINT_VAR: Boolean for deltamode calls - pulled from object
flags'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
first_sync_delta_enabled:
name: first_sync_delta_enabled
annotations:
order:
tag: order
value: 242
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: first_sync_delta_enabled
description: 'CHECKPOINT_VAR: internal variable for first_sync_delta_enabled'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: boolean
required: false
first_iter_counter:
name: first_iter_counter
annotations:
order:
tag: order
value: 243
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: first_iter_counter
description: 'CHECKPOINT_VAR: internal variable for first_iter_counter'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: string
required: false
first_run:
name: first_run
annotations:
order:
tag: order
value: 244
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: first_run
description: 'CHECKPOINT_VAR: internal variable for first_run'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
owner: inverter
domain_of:
- controller_dg
- inverter
range: boolean
required: false
prev_value_IGenerated_A:
name: prev_value_IGenerated_A
annotations:
order:
tag: order
value: 245
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_value_IGenerated_A
description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[0]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
prev_value_IGenerated_B:
name: prev_value_IGenerated_B
annotations:
order:
tag: order
value: 246
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_value_IGenerated_B
description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[1]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
prev_value_IGenerated_C:
name: prev_value_IGenerated_C
annotations:
order:
tag: order
value: 247
value_type:
tag: value_type
value: complex
native_name:
tag: native_name
value: prev_value_IGenerated_C
description: 'CHECKPOINT_VAR: internal variable for prev_value_IGenerated[2]'
from_schema: https://gridlabd.org/schema/glm/generators/inverter
rank: 1000
owner: inverter
domain_of:
- inverter
range: Complex
required: false
name:
name: name
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: name
description: The object's name; unique across the model.
comments:
- 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
(none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
share raises.'
from_schema: https://gridlabd.org/schema/glm/types/common
exact_mappings:
- cim:IdentifiedObject.name
rank: 1000
identifier: true
owner: inverter
domain_of:
- glm_object
range: string
required: true
parent:
name: parent
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: parent
description: The parent object's name. A child node is solved as its parent's
bus; a nested object block sets it to the enclosing object.
comments:
- 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
on the root''s row; no object of its own. On a link it is not mapped.'
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: inverter
domain_of:
- glm_object
range: string
groupid:
name: groupid
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: groupid
description: Free-text group label.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: inverter
domain_of:
- glm_object
range: string
latitude:
name: latitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: latitude
description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: inverter
domain_of:
- glm_object
range: string
longitude:
name: longitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: longitude
description: Longitude, as written.
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: inverter
domain_of:
- glm_object
range: string
in_svc:
name: in_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: in_svc
description: Timestamp the object enters service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: inverter
domain_of:
- glm_object
range: string
out_svc:
name: out_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: out_svc
description: Timestamp the object leaves service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: inverter
domain_of:
- glm_object
range: string
rank:
name: rank
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: rank
description: Solver rank.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: inverter
domain_of:
- glm_object
range: string
flags:
name: flags
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: flags
description: Core object flags.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: inverter
domain_of:
- glm_object
range: string