Class: Substation

Copyright (C) 2009 Battelle Memorial Institute

@file substation.cpp

@addtogroup powerflow_meter Substation

@ingroup powerflow

Substation object serves as a connecting object between the powerflow

and network solvers. The three-phase unbalanced connections of the

distribution solver are posted as an equivalent per-unit load on the network

solver. The network solver per-unit voltage is translated into a balanced

three-phase voltage for the distribution solver. This functionality assumes

the substation is treated as the swing bus for the distribution solver.

Total cumulative energy, instantantenous power and peak demand are

metered.

@{

__

Inherits from: node

__

Type: Instance (network topology element)

URI: glm:Substation

 classDiagram
    class Substation
    click Substation href "../Substation/"
      Node <|-- Substation
        click Node href "../Node/"

      Substation : base_power

      Substation : behaving_as_swing

      Substation : busflags

      Substation : bustype

      Substation : condition

      Substation : current_A





        Substation --> "0..1" Complex : current_A
        click Complex href "../Complex/"



      Substation : current_AB





        Substation --> "0..1" Complex : current_AB
        click Complex href "../Complex/"



      Substation : current_AN





        Substation --> "0..1" Complex : current_AN
        click Complex href "../Complex/"



      Substation : current_B





        Substation --> "0..1" Complex : current_B
        click Complex href "../Complex/"



      Substation : current_BC





        Substation --> "0..1" Complex : current_BC
        click Complex href "../Complex/"



      Substation : current_BN





        Substation --> "0..1" Complex : current_BN
        click Complex href "../Complex/"



      Substation : current_C





        Substation --> "0..1" Complex : current_C
        click Complex href "../Complex/"



      Substation : current_CA





        Substation --> "0..1" Complex : current_CA
        click Complex href "../Complex/"



      Substation : current_CN





        Substation --> "0..1" Complex : current_CN
        click Complex href "../Complex/"



      Substation : current_inj_A





        Substation --> "0..1" Complex : current_inj_A
        click Complex href "../Complex/"



      Substation : current_inj_B





        Substation --> "0..1" Complex : current_inj_B
        click Complex href "../Complex/"



      Substation : current_inj_C





        Substation --> "0..1" Complex : current_inj_C
        click Complex href "../Complex/"



      Substation : current_uptime

      Substation : deltamode_full_Y_all_matrix

      Substation : deltamode_full_Y_matrix

      Substation : deltamode_generator_current_A





        Substation --> "0..1" Complex : deltamode_generator_current_A
        click Complex href "../Complex/"



      Substation : deltamode_generator_current_B





        Substation --> "0..1" Complex : deltamode_generator_current_B
        click Complex href "../Complex/"



      Substation : deltamode_generator_current_C





        Substation --> "0..1" Complex : deltamode_generator_current_C
        click Complex href "../Complex/"



      Substation : deltamode_PGenTotal





        Substation --> "0..1" Complex : deltamode_PGenTotal
        click Complex href "../Complex/"



      Substation : distribution_current_A





        Substation --> "0..1" Complex : distribution_current_A
        click Complex href "../Complex/"



      Substation : distribution_current_B





        Substation --> "0..1" Complex : distribution_current_B
        click Complex href "../Complex/"



      Substation : distribution_current_C





        Substation --> "0..1" Complex : distribution_current_C
        click Complex href "../Complex/"



      Substation : distribution_load





        Substation --> "0..1" Complex : distribution_load
        click Complex href "../Complex/"



      Substation : distribution_power_A





        Substation --> "0..1" Complex : distribution_power_A
        click Complex href "../Complex/"



      Substation : distribution_power_B





        Substation --> "0..1" Complex : distribution_power_B
        click Complex href "../Complex/"



      Substation : distribution_power_C





        Substation --> "0..1" Complex : distribution_power_C
        click Complex href "../Complex/"



      Substation : distribution_real_energy

      Substation : distribution_voltage_A





        Substation --> "0..1" Complex : distribution_voltage_A
        click Complex href "../Complex/"



      Substation : distribution_voltage_AB





        Substation --> "0..1" Complex : distribution_voltage_AB
        click Complex href "../Complex/"



      Substation : distribution_voltage_B





        Substation --> "0..1" Complex : distribution_voltage_B
        click Complex href "../Complex/"



      Substation : distribution_voltage_BC





        Substation --> "0..1" Complex : distribution_voltage_BC
        click Complex href "../Complex/"



      Substation : distribution_voltage_C





        Substation --> "0..1" Complex : distribution_voltage_C
        click Complex href "../Complex/"



      Substation : distribution_voltage_CA





        Substation --> "0..1" Complex : distribution_voltage_CA
        click Complex href "../Complex/"



      Substation : flags

      Substation : frequency_measure_type

      Substation : generator_dynamic

      Substation : GFA_enable

      Substation : GFA_freq_disconnect_time

      Substation : GFA_freq_high_trip

      Substation : GFA_freq_low_trip

      Substation : GFA_reconnect_time

      Substation : GFA_status

      Substation : GFA_trip_method

      Substation : GFA_volt_disconnect_time

      Substation : GFA_volt_high_trip

      Substation : GFA_volt_low_trip

      Substation : groupid

      Substation : house_present

      Substation : in_svc

      Substation : inrush_integration_method

      Substation : latitude

      Substation : longitude

      Substation : maximum_voltage_error

      Substation : mean_repair_time

      Substation : measured_angle_A

      Substation : measured_angle_B

      Substation : measured_angle_C

      Substation : measured_frequency

      Substation : measured_frequency_A

      Substation : measured_frequency_B

      Substation : measured_frequency_C

      Substation : name

      Substation : negative_sequence_voltage





        Substation --> "0..1" Complex : negative_sequence_voltage
        click Complex href "../Complex/"



      Substation : nominal_voltage

      Substation : Norton_dynamic

      Substation : Norton_dynamic_child

      Substation : NR_powerflow_parent

      Substation : out_svc

      Substation : parent

      Substation : phases

      Substation : pll_Ki

      Substation : pll_Kp

      Substation : positive_sequence_voltage





        Substation --> "0..1" Complex : positive_sequence_voltage
        click Complex href "../Complex/"



      Substation : power_A





        Substation --> "0..1" Complex : power_A
        click Complex href "../Complex/"



      Substation : power_AB





        Substation --> "0..1" Complex : power_AB
        click Complex href "../Complex/"



      Substation : power_AN





        Substation --> "0..1" Complex : power_AN
        click Complex href "../Complex/"



      Substation : power_B





        Substation --> "0..1" Complex : power_B
        click Complex href "../Complex/"



      Substation : power_BC





        Substation --> "0..1" Complex : power_BC
        click Complex href "../Complex/"



      Substation : power_BN





        Substation --> "0..1" Complex : power_BN
        click Complex href "../Complex/"



      Substation : power_C





        Substation --> "0..1" Complex : power_C
        click Complex href "../Complex/"



      Substation : power_CA





        Substation --> "0..1" Complex : power_CA
        click Complex href "../Complex/"



      Substation : power_CN





        Substation --> "0..1" Complex : power_CN
        click Complex href "../Complex/"



      Substation : power_convergence_value

      Substation : prerotated_current_A





        Substation --> "0..1" Complex : prerotated_current_A
        click Complex href "../Complex/"



      Substation : prerotated_current_B





        Substation --> "0..1" Complex : prerotated_current_B
        click Complex href "../Complex/"



      Substation : prerotated_current_C





        Substation --> "0..1" Complex : prerotated_current_C
        click Complex href "../Complex/"



      Substation : previous_uptime

      Substation : rank

      Substation : reference_bus

      Substation : reference_phase

      Substation : reset_disabled_island_state

      Substation : residential_nominal_current_A





        Substation --> "0..1" Complex : residential_nominal_current_A
        click Complex href "../Complex/"



      Substation : residential_nominal_current_A_imag

      Substation : residential_nominal_current_A_real

      Substation : residential_nominal_current_B





        Substation --> "0..1" Complex : residential_nominal_current_B
        click Complex href "../Complex/"



      Substation : residential_nominal_current_B_imag

      Substation : residential_nominal_current_B_real

      Substation : residential_nominal_current_C





        Substation --> "0..1" Complex : residential_nominal_current_C
        click Complex href "../Complex/"



      Substation : residential_nominal_current_C_imag

      Substation : residential_nominal_current_C_real

      Substation : service_status

      Substation : service_status_double

      Substation : sfm_Tf

      Substation : shunt_A





        Substation --> "0..1" Complex : shunt_A
        click Complex href "../Complex/"



      Substation : shunt_AB





        Substation --> "0..1" Complex : shunt_AB
        click Complex href "../Complex/"



      Substation : shunt_AN





        Substation --> "0..1" Complex : shunt_AN
        click Complex href "../Complex/"



      Substation : shunt_B





        Substation --> "0..1" Complex : shunt_B
        click Complex href "../Complex/"



      Substation : shunt_BC





        Substation --> "0..1" Complex : shunt_BC
        click Complex href "../Complex/"



      Substation : shunt_BN





        Substation --> "0..1" Complex : shunt_BN
        click Complex href "../Complex/"



      Substation : shunt_C





        Substation --> "0..1" Complex : shunt_C
        click Complex href "../Complex/"



      Substation : shunt_CA





        Substation --> "0..1" Complex : shunt_CA
        click Complex href "../Complex/"



      Substation : shunt_CN





        Substation --> "0..1" Complex : shunt_CN
        click Complex href "../Complex/"



      Substation : solution

      Substation : topological_parent

      Substation : transmission_level_constant_current_load





        Substation --> "0..1" Complex : transmission_level_constant_current_load
        click Complex href "../Complex/"



      Substation : transmission_level_constant_impedance_load





        Substation --> "0..1" Complex : transmission_level_constant_impedance_load
        click Complex href "../Complex/"



      Substation : transmission_level_constant_power_load





        Substation --> "0..1" Complex : transmission_level_constant_power_load
        click Complex href "../Complex/"



      Substation : voltage_A





        Substation --> "0..1" Complex : voltage_A
        click Complex href "../Complex/"



      Substation : voltage_AB





        Substation --> "0..1" Complex : voltage_AB
        click Complex href "../Complex/"



      Substation : voltage_B





        Substation --> "0..1" Complex : voltage_B
        click Complex href "../Complex/"



      Substation : voltage_BC





        Substation --> "0..1" Complex : voltage_BC
        click Complex href "../Complex/"



      Substation : voltage_C





        Substation --> "0..1" Complex : voltage_C
        click Complex href "../Complex/"



      Substation : voltage_CA





        Substation --> "0..1" Complex : voltage_CA
        click Complex href "../Complex/"



      Substation : zero_sequence_voltage





        Substation --> "0..1" Complex : zero_sequence_voltage
        click Complex href "../Complex/"



Inheritance

Slots

Name Cardinality and Range Description Inheritance
zero_sequence_voltage 0..1
Complex
The zero sequence representation of the voltage for the substation object direct
positive_sequence_voltage 0..1
Complex
The positive sequence representation of the voltage for the substation object direct
negative_sequence_voltage 0..1
Complex
The negative sequence representation of the voltage for the substation object direct
base_power 0..1
Float
The 3 phase VA power rating of the substation direct
power_convergence_value 0..1
Float
Default convergence criterion before power is posted to pw_load objects if co... direct
reference_phase 0..1
String
The reference phase for the positive sequence voltage direct
transmission_level_constant_power_load 0..1
Complex
the average constant power load to be posted directly to the pw_load object direct
transmission_level_constant_current_load 0..1
Complex
the average constant current load at nominal voltage to be posted directly to... direct
transmission_level_constant_impedance_load 0..1
Complex
the average constant impedance load at nominal voltage to be posted directly ... direct
distribution_load 0..1
Complex
The total load of all three phases at the substation object direct
distribution_power_A 0..1
Complex
direct
distribution_power_B 0..1
Complex
direct
distribution_power_C 0..1
Complex
direct
distribution_voltage_A 0..1
Complex
direct
distribution_voltage_B 0..1
Complex
direct
distribution_voltage_C 0..1
Complex
direct
distribution_voltage_AB 0..1
Complex
direct
distribution_voltage_BC 0..1
Complex
direct
distribution_voltage_CA 0..1
Complex
direct
distribution_current_A 0..1
Complex
direct
distribution_current_B 0..1
Complex
direct
distribution_current_C 0..1
Complex
direct
distribution_real_energy 0..1
Float
direct
bustype 0..1
String
defines whether the node is a PQ, PV, or SWING node Node
busflags 0..1
String
flag indicates node has a source for voltage, i Node
reference_bus 0..1
String
reference bus from which frequency is defined Node
maximum_voltage_error 0..1
Float
convergence voltage limit or convergence criteria Node
voltage_A 0..1
Complex
bus voltage, Phase A to ground Node
voltage_B 0..1
Complex
bus voltage, Phase B to ground Node
voltage_C 0..1
Complex
bus voltage, Phase C to ground Node
voltage_AB 0..1
Complex
line voltages, Phase AB Node
voltage_BC 0..1
Complex
line voltages, Phase BC Node
voltage_CA 0..1
Complex
line voltages, Phase CA Node
current_A 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
current_B 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
current_C 0..1
Complex
bus current injection (in = positive), this an accumulator only, not a output... Node
power_A 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
power_B 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
power_C 0..1
Complex
bus power injection (in = positive), this an accumulator only, not a output o... Node
shunt_A 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
shunt_B 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
shunt_C 0..1
Complex
bus shunt admittance, this an accumulator only, not a output or input variabl... Node
prerotated_current_A 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
prerotated_current_B 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
prerotated_current_C 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... Node
deltamode_generator_current_A 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_generator_current_B 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_generator_current_C 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... Node
deltamode_PGenTotal 0..1
Complex
deltamode-functionality - power value for a diesel generator -- accumulator o... Node
deltamode_full_Y_matrix 0..1
String
deltamode-functionality full_Y matrix exposes so generator objects can intera... Node
deltamode_full_Y_all_matrix 0..1
String
deltamode-functionality full_Y_all matrix exposes so generator objects can in... Node
NR_powerflow_parent 0..1
String
NR powerflow - actual powerflow parent - used by generators accessing child o... Node
current_inj_A 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_inj_B 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_inj_C 0..1
Complex
bus current injection (in = positive), but will not be rotated by powerflow f... Node
current_AB 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_BC 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_CA 0..1
Complex
bus current delta-connected injection (in = positive), this an accumulator on... Node
current_AN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
current_BN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
current_CN 0..1
Complex
bus current wye-connected injection (in = positive), this an accumulator only... Node
power_AB 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_BC 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_CA 0..1
Complex
bus power delta-connected injection (in = positive), this an accumulator only... Node
power_AN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
power_BN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
power_CN 0..1
Complex
bus power wye-connected injection (in = positive), this an accumulator only, ... Node
shunt_AB 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_BC 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_CA 0..1
Complex
bus shunt delta-connected admittance, this an accumulator only, not a output ... Node
shunt_AN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
shunt_BN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
shunt_CN 0..1
Complex
bus shunt wye-connected admittance, this an accumulator only, not a output or... Node
residential_nominal_current_A 0..1
Complex
posted current on phase A from a residential object, if attached Node
residential_nominal_current_B 0..1
Complex
posted current on phase B from a residential object, if attached Node
residential_nominal_current_C 0..1
Complex
posted current on phase C from a residential object, if attached Node
residential_nominal_current_A_real 0..1
Float
posted current on phase A, real, from a residential object, if attached Node
residential_nominal_current_A_imag 0..1
Float
posted current on phase A, imag, from a residential object, if attached Node
residential_nominal_current_B_real 0..1
Float
posted current on phase B, real, from a residential object, if attached Node
residential_nominal_current_B_imag 0..1
Float
posted current on phase B, imag, from a residential object, if attached Node
residential_nominal_current_C_real 0..1
Float
posted current on phase C, real, from a residential object, if attached Node
residential_nominal_current_C_imag 0..1
Float
posted current on phase C, imag, from a residential object, if attached Node
house_present 0..1
Boolean
boolean for detecting whether a house is attached, not an input Node
mean_repair_time 0..1
Float
Time after a fault clears for the object to be back in service Node
frequency_measure_type 0..1
String
PLL frequency measurement Node
sfm_Tf 0..1
Float
Transducer time constant for simplified frequency measurement (seconds) Node
pll_Kp 0..1
Float
Proportional gain of PLL frequency measurement Node
pll_Ki 0..1
Float
Integration gain of PLL frequency measurement Node
measured_angle_A 0..1
Float
bus angle measurement, phase A Node
measured_frequency_A 0..1
Float
frequency measurement, phase A Node
measured_angle_B 0..1
Float
bus angle measurement, phase B Node
measured_frequency_B 0..1
Float
frequency measurement, phase B Node
measured_angle_C 0..1
Float
bus angle measurement, phase C Node
measured_frequency_C 0..1
Float
frequency measurement, phase C Node
measured_frequency 0..1
Float
frequency measurement - average of present phases Node
service_status 0..1
String
In and out of service flag Node
service_status_double 0..1
Float
In and out of service flag - type double - will indiscriminately override ser... Node
previous_uptime 0..1
Float
Previous time between disconnects of node in minutes Node
current_uptime 0..1
Float
Current time since last disconnect of node in minutes Node
Norton_dynamic 0..1
Boolean
Flag to indicate a Norton-equivalent connection -- used for generators and de... Node
Norton_dynamic_child 0..1
Boolean
Flag to indicate a Norton-equivalent connection is made by a childed node obj... Node
generator_dynamic 0..1
Boolean
Flag to indicate a voltage-sourcing or swing-type generator is present -- use... Node
reset_disabled_island_state 0..1
Boolean
Deltamode/multi-island flag -- used to reset disabled status (and reform an i... Node
GFA_enable 0..1
Boolean
Disable/Enable Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_low_trip 0..1
Float
Low frequency trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_high_trip 0..1
Float
High frequency trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_volt_low_trip 0..1
Float
Low voltage trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_volt_high_trip 0..1
Float
High voltage trip point for Grid Friendly Appliance(TM)-type functionality Node
GFA_reconnect_time 0..1
Float
Reconnect time for Grid Friendly Appliance(TM)-type functionality Node
GFA_freq_disconnect_time 0..1
Float
Frequency violation disconnect time for Grid Friendly Appliance(TM)-type func... Node
GFA_volt_disconnect_time 0..1
Float
Voltage violation disconnect time for Grid Friendly Appliance(TM)-type functi... Node
GFA_status 0..1
Boolean
Grid Friendly Appliance(TM)-type functionality - whether it is in service (no... Node
GFA_trip_method 0..1
String
GFA trip for over-voltage Node
topological_parent 0..1
String
topological parent as per GLM configuration Node
behaving_as_swing 0..1
Boolean
Indicator flag for if a bus is behaving as a reference voltage source - valid... Node
phases 0..1
String
PowerflowObject
nominal_voltage 0..1
Float
PowerflowObject
inrush_integration_method 0..1
String
Integration method for in-rush PowerflowObject
condition 0..1
String
PowerflowObject
solution 0..1
String
PowerflowObject
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: EnergySource, mRID src_ + name (source.cimtbl), on a ConnectivityNode named name (bus.cimtbl); base_power gives BasePower, mRID sbase_ + name. Export: the EnergySource, with the graph's one BasePower.

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:Substation
native glm:Substation
exact cim:EnergySource
close cim:ConnectivityNode, cim:BasePower

LinkML Source

Direct

name: substation
description: 'Copyright (C) 2009 Battelle Memorial Institute

  @file substation.cpp

  @addtogroup powerflow_meter Substation

  @ingroup powerflow

  Substation object serves as a connecting object between the powerflow

  and network solvers.  The three-phase unbalanced connections of the

  distribution solver are posted as an equivalent per-unit load on the network

  solver.  The network solver per-unit voltage is translated into a balanced

  three-phase voltage for the distribution solver.  This functionality assumes

  the substation is treated as the swing bus for the distribution solver.

  Total cumulative energy, instantantenous power and peak demand are

  metered.

  @{


  Inherits from: node


  Type: Instance (network topology element)'
comments:
- 'Import: EnergySource, mRID src_ + name (source.cimtbl), on a ConnectivityNode named
  name (bus.cimtbl); base_power gives BasePower, mRID sbase_ + name. Export: the EnergySource,
  with the graph''s one BasePower.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:EnergySource
close_mappings:
- cim:ConnectivityNode
- cim:BasePower
is_a: node
attributes:
  zero_sequence_voltage:
    name: zero_sequence_voltage
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: zero_sequence_voltage[V]
    description: The zero sequence representation of the voltage for the substation
      object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  positive_sequence_voltage:
    name: positive_sequence_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: positive_sequence_voltage[V]
    description: The positive sequence representation of the voltage for the substation
      object.
    comments:
    - 'Import: EnergySource.voltageMagnitude (line to line) and voltageAngle (deg)
      from |V| and arg(V); else voltage_A, else nominal_voltage at 0 deg. Export:
      get_source voltageMagnitude / sqrt 3 at voltageAngle.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    close_mappings:
    - cim:EnergySource.voltageMagnitude
    - cim:EnergySource.voltageAngle
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  negative_sequence_voltage:
    name: negative_sequence_voltage
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: negative_sequence_voltage[V]
    description: The negative sequence representation of the voltage for the substation
      object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  base_power:
    name: base_power
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power[VA]
    description: The 3 phase VA power rating of the substation.
    comments:
    - 'Import: BasePower.basePower, in the unit written. Export: the graph''s BasePower,
      when it has one.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    exact_mappings:
    - cim:BasePower.basePower
    domain_of:
    - motor
    - substation
    - ZIPload
    range: float
    required: false
    unit:
      ucum_code: VA
  power_convergence_value:
    name: power_convergence_value
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_convergence_value[VA]
    description: Default convergence criterion before power is posted to pw_load objects
      if connected, otherwise ignored
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: float
    required: false
    unit:
      ucum_code: VA
  reference_phase:
    name: reference_phase
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reference_phase
    description: The reference phase for the positive sequence voltage.
    comments:
    - 'Import: structural; unset or PHASE_A, any other raises. Export: not written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: string
    required: false
  transmission_level_constant_power_load:
    name: transmission_level_constant_power_load
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: transmission_level_constant_power_load[VA]
    description: the average constant power load to be posted directly to the pw_load
      object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  transmission_level_constant_current_load:
    name: transmission_level_constant_current_load
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: transmission_level_constant_current_load[A]
    description: the average constant current load at nominal voltage to be posted
      directly to the pw_load object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: A
  transmission_level_constant_impedance_load:
    name: transmission_level_constant_impedance_load
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: transmission_level_constant_impedance_load[Ohm]
    description: the average constant impedance load at nominal voltage to be posted
      directly to the pw_load object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  distribution_load:
    name: distribution_load
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_load[VA]
    description: The total load of all three phases at the substation object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  distribution_power_A:
    name: distribution_power_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_power_A[VA]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  distribution_power_B:
    name: distribution_power_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_power_B[VA]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  distribution_power_C:
    name: distribution_power_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_power_C[VA]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  distribution_voltage_A:
    name: distribution_voltage_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_A[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_B:
    name: distribution_voltage_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_B[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_C:
    name: distribution_voltage_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_C[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_AB:
    name: distribution_voltage_AB
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_AB[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_BC:
    name: distribution_voltage_BC
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_BC[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_CA:
    name: distribution_voltage_CA
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_CA[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_current_A:
    name: distribution_current_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_current_A[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: A
  distribution_current_B:
    name: distribution_current_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_current_B[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: A
  distribution_current_C:
    name: distribution_current_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_current_C[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: A
  distribution_real_energy:
    name: distribution_real_energy
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: distribution_real_energy[Wh]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    domain_of:
    - substation
    range: float
    required: false
    unit:
      ucum_code: Wh

Induced

name: substation
description: 'Copyright (C) 2009 Battelle Memorial Institute

  @file substation.cpp

  @addtogroup powerflow_meter Substation

  @ingroup powerflow

  Substation object serves as a connecting object between the powerflow

  and network solvers.  The three-phase unbalanced connections of the

  distribution solver are posted as an equivalent per-unit load on the network

  solver.  The network solver per-unit voltage is translated into a balanced

  three-phase voltage for the distribution solver.  This functionality assumes

  the substation is treated as the swing bus for the distribution solver.

  Total cumulative energy, instantantenous power and peak demand are

  metered.

  @{


  Inherits from: node


  Type: Instance (network topology element)'
comments:
- 'Import: EnergySource, mRID src_ + name (source.cimtbl), on a ConnectivityNode named
  name (bus.cimtbl); base_power gives BasePower, mRID sbase_ + name. Export: the EnergySource,
  with the graph''s one BasePower.'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:EnergySource
close_mappings:
- cim:ConnectivityNode
- cim:BasePower
is_a: node
attributes:
  zero_sequence_voltage:
    name: zero_sequence_voltage
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: zero_sequence_voltage[V]
    description: The zero sequence representation of the voltage for the substation
      object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  positive_sequence_voltage:
    name: positive_sequence_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: positive_sequence_voltage[V]
    description: The positive sequence representation of the voltage for the substation
      object.
    comments:
    - 'Import: EnergySource.voltageMagnitude (line to line) and voltageAngle (deg)
      from |V| and arg(V); else voltage_A, else nominal_voltage at 0 deg. Export:
      get_source voltageMagnitude / sqrt 3 at voltageAngle.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    close_mappings:
    - cim:EnergySource.voltageMagnitude
    - cim:EnergySource.voltageAngle
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  negative_sequence_voltage:
    name: negative_sequence_voltage
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: negative_sequence_voltage[V]
    description: The negative sequence representation of the voltage for the substation
      object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  base_power:
    name: base_power
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power[VA]
    description: The 3 phase VA power rating of the substation.
    comments:
    - 'Import: BasePower.basePower, in the unit written. Export: the graph''s BasePower,
      when it has one.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    exact_mappings:
    - cim:BasePower.basePower
    owner: substation
    domain_of:
    - motor
    - substation
    - ZIPload
    range: float
    required: false
    unit:
      ucum_code: VA
  power_convergence_value:
    name: power_convergence_value
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_convergence_value[VA]
    description: Default convergence criterion before power is posted to pw_load objects
      if connected, otherwise ignored
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: float
    required: false
    unit:
      ucum_code: VA
  reference_phase:
    name: reference_phase
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reference_phase
    description: The reference phase for the positive sequence voltage.
    comments:
    - 'Import: structural; unset or PHASE_A, any other raises. Export: not written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: string
    required: false
  transmission_level_constant_power_load:
    name: transmission_level_constant_power_load
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: transmission_level_constant_power_load[VA]
    description: the average constant power load to be posted directly to the pw_load
      object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  transmission_level_constant_current_load:
    name: transmission_level_constant_current_load
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: transmission_level_constant_current_load[A]
    description: the average constant current load at nominal voltage to be posted
      directly to the pw_load object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: A
  transmission_level_constant_impedance_load:
    name: transmission_level_constant_impedance_load
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: transmission_level_constant_impedance_load[Ohm]
    description: the average constant impedance load at nominal voltage to be posted
      directly to the pw_load object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  distribution_load:
    name: distribution_load
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_load[VA]
    description: The total load of all three phases at the substation object.
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  distribution_power_A:
    name: distribution_power_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_power_A[VA]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  distribution_power_B:
    name: distribution_power_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_power_B[VA]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  distribution_power_C:
    name: distribution_power_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_power_C[VA]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: VA
  distribution_voltage_A:
    name: distribution_voltage_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_A[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_B:
    name: distribution_voltage_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_B[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_C:
    name: distribution_voltage_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_C[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_AB:
    name: distribution_voltage_AB
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_AB[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_BC:
    name: distribution_voltage_BC
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_BC[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_voltage_CA:
    name: distribution_voltage_CA
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_voltage_CA[V]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: V
  distribution_current_A:
    name: distribution_current_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_current_A[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: A
  distribution_current_B:
    name: distribution_current_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_current_B[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: A
  distribution_current_C:
    name: distribution_current_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: distribution_current_C[A]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: Complex
    required: false
    unit:
      ucum_code: A
  distribution_real_energy:
    name: distribution_real_energy
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: distribution_real_energy[Wh]
    from_schema: https://gridlabd.org/schema/glm/powerflow/substation
    rank: 1000
    owner: substation
    domain_of:
    - substation
    range: float
    required: false
    unit:
      ucum_code: Wh
  bustype:
    name: bustype
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: bustype
    description: defines whether the node is a PQ, PV, or SWING node
    comments:
    - 'Import: SWING makes an EnergySource; PQ, PV and SWING_PQ are a plain bus (SWING_PQ
      is a swing only when islanded). Export: SWING on the substation only.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    related_mappings:
    - cim:EnergySource
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  busflags:
    name: busflags
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: busflags
    description: flag indicates node has a source for voltage, i.e. connects to the
      swing node
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  reference_bus:
    name: reference_bus
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reference_bus
    description: reference bus from which frequency is defined
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  maximum_voltage_error:
    name: maximum_voltage_error
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_voltage_error[V]
    description: convergence voltage limit or convergence criteria
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: V
  voltage_A:
    name: voltage_A
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_A[V]
    description: bus voltage, Phase A to ground
    comments:
    - 'Import: on a SWING bus only: EnergySource.voltageMagnitude (line to line) and
      voltageAngle (deg) from |V| and arg(V); elsewhere the solver guess, not converted.
      Export: not written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    close_mappings:
    - cim:EnergySource.voltageMagnitude
    - cim:EnergySource.voltageAngle
    rank: 1000
    owner: substation
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_B:
    name: voltage_B
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_B[V]
    description: bus voltage, Phase B to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_C:
    name: voltage_C
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_C[V]
    description: bus voltage, Phase C to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_AB:
    name: voltage_AB
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_AB[V]
    description: line voltages, Phase AB
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_BC:
    name: voltage_BC
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_BC[V]
    description: line voltages, Phase BC
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_CA:
    name: voltage_CA
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_CA[V]
    description: line voltages, Phase CA
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: V
  current_A:
    name: current_A
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_A[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_B:
    name: current_B
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_B[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_C:
    name: current_C
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_C[A]
    description: bus current injection (in = positive), this an accumulator only,
      not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - rectifier
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_A:
    name: power_A
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_A[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_B:
    name: power_B
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_B[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_C:
    name: power_C
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_C[VA]
    description: bus power injection (in = positive), this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - inverter
    - inverter_dyn
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_A:
    name: shunt_A
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_A[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_B:
    name: shunt_B
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_B[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_C:
    name: shunt_C
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_C[S]
    description: bus shunt admittance, this an accumulator only, not a output or input
      variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  prerotated_current_A:
    name: prerotated_current_A
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_A[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_B:
    name: prerotated_current_B
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_B[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_C:
    name: prerotated_current_C
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_C[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_A:
    name: deltamode_generator_current_A
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_A[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_B:
    name: deltamode_generator_current_B
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_B[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_C:
    name: deltamode_generator_current_C
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_C[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_PGenTotal:
    name: deltamode_PGenTotal
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_PGenTotal
    description: deltamode-functionality - power value for a diesel generator -- accumulator
      only, not an output or input
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: Complex
    required: false
  deltamode_full_Y_matrix:
    name: deltamode_full_Y_matrix
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_matrix
    description: deltamode-functionality full_Y matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  deltamode_full_Y_all_matrix:
    name: deltamode_full_Y_all_matrix
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_all_matrix
    description: deltamode-functionality full_Y_all matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  NR_powerflow_parent:
    name: NR_powerflow_parent
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: NR_powerflow_parent
    description: NR powerflow - actual powerflow parent - used by generators accessing
      child objects
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  current_inj_A:
    name: current_inj_A
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_A[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_inj_B:
    name: current_inj_B
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_B[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_inj_C:
    name: current_inj_C
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_inj_C[A]
    description: bus current injection (in = positive), but will not be rotated by
      powerflow for off-nominal frequency, this an accumulator only, not a output
      or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_AB:
    name: current_AB
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_AB[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_BC:
    name: current_BC
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_BC[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_CA:
    name: current_CA
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_CA[A]
    description: bus current delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_AN:
    name: current_AN
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_AN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_BN:
    name: current_BN
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_BN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_CN:
    name: current_CN
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_CN[A]
    description: bus current wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_AB:
    name: power_AB
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_AB[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_BC:
    name: power_BC
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_BC[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_CA:
    name: power_CA
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_CA[VA]
    description: bus power delta-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_AN:
    name: power_AN
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_AN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_BN:
    name: power_BN
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_BN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_CN:
    name: power_CN
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_CN[VA]
    description: bus power wye-connected injection (in = positive), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_AB:
    name: shunt_AB
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_AB[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_BC:
    name: shunt_BC
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_BC[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_CA:
    name: shunt_CA
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_CA[S]
    description: bus shunt delta-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_AN:
    name: shunt_AN
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_AN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_BN:
    name: shunt_BN
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_BN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_CN:
    name: shunt_CN
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_CN[S]
    description: bus shunt wye-connected admittance, this an accumulator only, not
      a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: S
  residential_nominal_current_A:
    name: residential_nominal_current_A
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_A[A]
    description: posted current on phase A from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B:
    name: residential_nominal_current_B
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_B[A]
    description: posted current on phase B from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C:
    name: residential_nominal_current_C
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_C[A]
    description: posted current on phase C from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_A_real:
    name: residential_nominal_current_A_real
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_A_real[A]
    description: posted current on phase A, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_A_imag:
    name: residential_nominal_current_A_imag
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_A_imag[A]
    description: posted current on phase A, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B_real:
    name: residential_nominal_current_B_real
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_B_real[A]
    description: posted current on phase B, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_B_imag:
    name: residential_nominal_current_B_imag
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_B_imag[A]
    description: posted current on phase B, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C_real:
    name: residential_nominal_current_C_real
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_C_real[A]
    description: posted current on phase C, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_C_imag:
    name: residential_nominal_current_C_imag
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_C_imag[A]
    description: posted current on phase C, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: A
  house_present:
    name: house_present
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: house_present
    description: boolean for detecting whether a house is attached, not an input
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  mean_repair_time:
    name: mean_repair_time
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: mean_repair_time[s]
    description: Time after a fault clears for the object to be back in service
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    owner: substation
    domain_of:
    - link
    - node
    range: float
    required: false
    unit:
      ucum_code: s
  frequency_measure_type:
    name: frequency_measure_type
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: frequency_measure_type
    description: PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  sfm_Tf:
    name: sfm_Tf
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sfm_Tf[s]
    description: Transducer time constant for simplified frequency measurement (seconds)
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  pll_Kp:
    name: pll_Kp
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Kp[pu]
    description: Proportional gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  pll_Ki:
    name: pll_Ki
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Ki[pu]
    description: Integration gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  measured_angle_A:
    name: measured_angle_A
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_A[rad]
    description: bus angle measurement, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_A:
    name: measured_frequency_A
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_A[Hz]
    description: frequency measurement, phase A
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_B:
    name: measured_angle_B
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_B[rad]
    description: bus angle measurement, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_B:
    name: measured_frequency_B
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_B[Hz]
    description: frequency measurement, phase B
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_C:
    name: measured_angle_C
    annotations:
      order:
        tag: order
        value: 70
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_C[rad]
    description: bus angle measurement, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_C:
    name: measured_frequency_C
    annotations:
      order:
        tag: order
        value: 71
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_C[Hz]
    description: frequency measurement, phase C
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_frequency:
    name: measured_frequency
    annotations:
      order:
        tag: order
        value: 72
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency[Hz]
    description: frequency measurement - average of present phases
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  service_status:
    name: service_status
    annotations:
      order:
        tag: order
        value: 73
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: service_status
    description: In and out of service flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  service_status_double:
    name: service_status_double
    annotations:
      order:
        tag: order
        value: 74
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: service_status_double
    description: In and out of service flag - type double - will indiscriminately
      override service_status - useful for schedules
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
  previous_uptime:
    name: previous_uptime
    annotations:
      order:
        tag: order
        value: 75
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_uptime[min]
    description: Previous time between disconnects of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  current_uptime:
    name: current_uptime
    annotations:
      order:
        tag: order
        value: 76
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_uptime[min]
    description: Current time since last disconnect of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  Norton_dynamic:
    name: Norton_dynamic
    annotations:
      order:
        tag: order
        value: 77
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic
    description: Flag to indicate a Norton-equivalent connection -- used for generators
      and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  Norton_dynamic_child:
    name: Norton_dynamic_child
    annotations:
      order:
        tag: order
        value: 78
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic_child
    description: Flag to indicate a Norton-equivalent connection is made by a childed
      node object -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  generator_dynamic:
    name: generator_dynamic
    annotations:
      order:
        tag: order
        value: 79
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: generator_dynamic
    description: Flag to indicate a voltage-sourcing or swing-type generator is present
      -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  reset_disabled_island_state:
    name: reset_disabled_island_state
    annotations:
      order:
        tag: order
        value: 80
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: reset_disabled_island_state
    description: Deltamode/multi-island flag -- used to reset disabled status (and
      reform an island)
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_enable:
    name: GFA_enable
    annotations:
      order:
        tag: order
        value: 81
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_enable
    description: Disable/Enable Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_freq_low_trip:
    name: GFA_freq_low_trip
    annotations:
      order:
        tag: order
        value: 82
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_low_trip[Hz]
    description: Low frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_freq_high_trip:
    name: GFA_freq_high_trip
    annotations:
      order:
        tag: order
        value: 83
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_high_trip[Hz]
    description: High frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_volt_low_trip:
    name: GFA_volt_low_trip
    annotations:
      order:
        tag: order
        value: 84
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_low_trip[pu]
    description: Low voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_volt_high_trip:
    name: GFA_volt_high_trip
    annotations:
      order:
        tag: order
        value: 85
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_high_trip[pu]
    description: High voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_reconnect_time:
    name: GFA_reconnect_time
    annotations:
      order:
        tag: order
        value: 86
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_reconnect_time[s]
    description: Reconnect time for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_freq_disconnect_time:
    name: GFA_freq_disconnect_time
    annotations:
      order:
        tag: order
        value: 87
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_disconnect_time[s]
    description: Frequency violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_volt_disconnect_time:
    name: GFA_volt_disconnect_time
    annotations:
      order:
        tag: order
        value: 88
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_disconnect_time[s]
    description: Voltage violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_status:
    name: GFA_status
    annotations:
      order:
        tag: order
        value: 89
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_status
    description: Grid Friendly Appliance(TM)-type functionality - whether it is in
      service (not tripped) or not
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_trip_method:
    name: GFA_trip_method
    annotations:
      order:
        tag: order
        value: 90
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: GFA_trip_method
    description: GFA trip for over-voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  topological_parent:
    name: topological_parent
    annotations:
      order:
        tag: order
        value: 91
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: topological_parent
    description: topological parent as per GLM configuration
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  behaving_as_swing:
    name: behaving_as_swing
    annotations:
      order:
        tag: order
        value: 92
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: behaving_as_swing
    description: Indicator flag for if a bus is behaving as a reference voltage source
      - valid for a SWING or SWING_PQ
    from_schema: https://gridlabd.org/schema/glm/powerflow/node
    rank: 1000
    owner: substation
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    comments:
    - 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
      Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
      Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
      when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
      bus); a switch or reactor side 1''s A, B, C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    related_mappings:
    - cim:Terminal.phases
    rank: 1000
    owner: substation
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  nominal_voltage:
    name: nominal_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_voltage[V]
    comments:
    - 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
      over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
      (V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
      LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
      / sqrt 3.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    close_mappings:
    - cim:BaseVoltage.nominalVoltage
    - cim:EnergySource.nominalVoltage
    rank: 1000
    owner: substation
    domain_of:
    - powerflow_object
    - battery
    - waterheater
    range: float
    required: false
    unit:
      ucum_code: V
  inrush_integration_method:
    name: inrush_integration_method
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method
    description: Integration method for in-rush
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: substation
    domain_of:
    - powerflow_object
    range: string
    required: false
  condition:
    name: condition
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: condition
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: substation
    domain_of:
    - powerflow_object
    range: string
    required: false
  solution:
    name: solution
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: solution
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: substation
    domain_of:
    - powerflow_object
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: substation
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: substation
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: substation
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: substation
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: substation
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: substation
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: substation
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: substation
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: substation
    domain_of:
    - glm_object
    range: string