Class: FaultCheck¶
Copyright (C) 2009 Battelle Memorial Institute
__
Inherits from: powerflow_object
URI: glm:FaultCheck
classDiagram
class FaultCheck
click FaultCheck href "../FaultCheck/"
PowerflowObject <|-- FaultCheck
click PowerflowObject href "../PowerflowObject/"
FaultCheck : check_mode
FaultCheck : condition
FaultCheck : eventgen_object
FaultCheck : flags
FaultCheck : full_output_file
FaultCheck : grid_association
FaultCheck : groupid
FaultCheck : in_svc
FaultCheck : inrush_integration_method
FaultCheck : latitude
FaultCheck : longitude
FaultCheck : name
FaultCheck : nominal_voltage
FaultCheck : out_svc
FaultCheck : output_filename
FaultCheck : parent
FaultCheck : phases
FaultCheck : rank
FaultCheck : reliability_mode
FaultCheck : solution
FaultCheck : strictly_radial
Inheritance¶
- GlmObject
- PowerflowObject
- FaultCheck
- PowerflowObject
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| check_mode | 0..1 String |
Frequency of fault checks | direct |
| output_filename | 0..1 String |
Output filename for list of unsupported nodes | direct |
| reliability_mode | 0..1 Boolean |
General flag indicating if fault_check is operating under faulting or restora... | direct |
| strictly_radial | 0..1 Boolean |
Flag to indicate if a system is known to be strictly radial -- uses radial as... | direct |
| full_output_file | 0..1 Boolean |
Flag to indicate if the output_filename report contains both supported and un... | direct |
| grid_association | 0..1 Boolean |
Flag to indicate if multiple, distinct grids are allowed in a GLM, or if anyt... | direct |
| eventgen_object | 0..1 String |
Link to generic eventgen object to handle unexpected faults | direct |
| phases | 0..1 String |
PowerflowObject | |
| nominal_voltage | 0..1 Float |
PowerflowObject | |
| inrush_integration_method | 0..1 String |
Integration method for in-rush | PowerflowObject |
| condition | 0..1 String |
PowerflowObject | |
| solution | 0..1 String |
PowerflowObject | |
| name | 1 String |
The object's name; unique across the model | GlmObject |
| parent | 0..1 String |
The parent object's name | GlmObject |
| groupid | 0..1 String |
Free-text group label | GlmObject |
| latitude | 0..1 String |
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) | GlmObject |
| longitude | 0..1 String |
Longitude, as written | GlmObject |
| in_svc | 0..1 String |
Timestamp the object enters service | GlmObject |
| out_svc | 0..1 String |
Timestamp the object leaves service | GlmObject |
| rank | 0..1 String |
Solver rank | GlmObject |
| flags | 0..1 String |
Core object flags | GlmObject |
Comments¶
- CIMHub does not convert this class. The importer reads no property of it and lists it, with its count, on the master's not-mapped comment; the exporter writes none.
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridlabd.org/schema/glm
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | glm:FaultCheck |
| native | glm:FaultCheck |
LinkML Source¶
Direct¶
name: fault_check
description: 'Copyright (C) 2009 Battelle Memorial Institute
Inherits from: powerflow_object'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: powerflow_object
attributes:
check_mode:
name: check_mode
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: check_mode
description: Frequency of fault checks
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
domain_of:
- fault_check
range: string
required: false
output_filename:
name: output_filename
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: output_filename
description: Output filename for list of unsupported nodes
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
domain_of:
- fault_check
- restoration
range: string
required: false
reliability_mode:
name: reliability_mode
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: reliability_mode
description: General flag indicating if fault_check is operating under faulting
or restoration mode -- reliability set this
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
domain_of:
- fault_check
range: boolean
required: false
strictly_radial:
name: strictly_radial
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: strictly_radial
description: Flag to indicate if a system is known to be strictly radial -- uses
radial assumptions for reliability alterations
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
domain_of:
- fault_check
range: boolean
required: false
full_output_file:
name: full_output_file
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: full_output_file
description: Flag to indicate if the output_filename report contains both supported
and unsupported nodes -- if false, just does unsupported
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
domain_of:
- fault_check
range: boolean
required: false
grid_association:
name: grid_association
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: grid_association
description: Flag to indicate if multiple, distinct grids are allowed in a GLM,
or if anything not attached to the master swing is removed
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
domain_of:
- fault_check
range: boolean
required: false
eventgen_object:
name: eventgen_object
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: eventgen_object
description: Link to generic eventgen object to handle unexpected faults
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
domain_of:
- fault_check
range: string
required: false
Induced¶
name: fault_check
description: 'Copyright (C) 2009 Battelle Memorial Institute
Inherits from: powerflow_object'
comments:
- CIMHub does not convert this class. The importer reads no property of it and lists
it, with its count, on the master's not-mapped comment; the exporter writes none.
from_schema: https://gridlabd.org/schema/glm
is_a: powerflow_object
attributes:
check_mode:
name: check_mode
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: check_mode
description: Frequency of fault checks
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
owner: fault_check
domain_of:
- fault_check
range: string
required: false
output_filename:
name: output_filename
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: output_filename
description: Output filename for list of unsupported nodes
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
owner: fault_check
domain_of:
- fault_check
- restoration
range: string
required: false
reliability_mode:
name: reliability_mode
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: reliability_mode
description: General flag indicating if fault_check is operating under faulting
or restoration mode -- reliability set this
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
owner: fault_check
domain_of:
- fault_check
range: boolean
required: false
strictly_radial:
name: strictly_radial
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: strictly_radial
description: Flag to indicate if a system is known to be strictly radial -- uses
radial assumptions for reliability alterations
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
owner: fault_check
domain_of:
- fault_check
range: boolean
required: false
full_output_file:
name: full_output_file
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: full_output_file
description: Flag to indicate if the output_filename report contains both supported
and unsupported nodes -- if false, just does unsupported
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
owner: fault_check
domain_of:
- fault_check
range: boolean
required: false
grid_association:
name: grid_association
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: bool
native_name:
tag: native_name
value: grid_association
description: Flag to indicate if multiple, distinct grids are allowed in a GLM,
or if anything not attached to the master swing is removed
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
owner: fault_check
domain_of:
- fault_check
range: boolean
required: false
eventgen_object:
name: eventgen_object
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: eventgen_object
description: Link to generic eventgen object to handle unexpected faults
from_schema: https://gridlabd.org/schema/glm/powerflow/fault_check
rank: 1000
owner: fault_check
domain_of:
- fault_check
range: string
required: false
phases:
name: phases
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: phases
comments:
- 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
bus); a switch or reactor side 1''s A, B, C.'
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
related_mappings:
- cim:Terminal.phases
rank: 1000
owner: fault_check
domain_of:
- powerflow_object
- inverter
- rectifier
- windturb_dg
range: string
required: false
nominal_voltage:
name: nominal_voltage
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 6
native_name:
tag: native_name
value: nominal_voltage[V]
comments:
- 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
(V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
/ sqrt 3.'
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
close_mappings:
- cim:BaseVoltage.nominalVoltage
- cim:EnergySource.nominalVoltage
rank: 1000
owner: fault_check
domain_of:
- powerflow_object
- battery
- waterheater
range: float
required: false
unit:
ucum_code: V
inrush_integration_method:
name: inrush_integration_method
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: inrush_integration_method
description: Integration method for in-rush
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
rank: 1000
owner: fault_check
domain_of:
- powerflow_object
range: string
required: false
condition:
name: condition
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: condition
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
rank: 1000
owner: fault_check
domain_of:
- powerflow_object
range: string
required: false
solution:
name: solution
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: solution
from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
rank: 1000
owner: fault_check
domain_of:
- powerflow_object
range: string
required: false
name:
name: name
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: name
description: The object's name; unique across the model.
comments:
- 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
(none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
share raises.'
from_schema: https://gridlabd.org/schema/glm/types/common
exact_mappings:
- cim:IdentifiedObject.name
rank: 1000
identifier: true
owner: fault_check
domain_of:
- glm_object
range: string
required: true
parent:
name: parent
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: parent
description: The parent object's name. A child node is solved as its parent's
bus; a nested object block sets it to the enclosing object.
comments:
- 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
on the root''s row; no object of its own. On a link it is not mapped.'
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: fault_check
domain_of:
- glm_object
range: string
groupid:
name: groupid
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: groupid
description: Free-text group label.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: fault_check
domain_of:
- glm_object
range: string
latitude:
name: latitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: latitude
description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: fault_check
domain_of:
- glm_object
range: string
longitude:
name: longitude
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: longitude
description: Longitude, as written.
comments:
- Not converted. Home is the EquipmentLocation shape.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: fault_check
domain_of:
- glm_object
range: string
in_svc:
name: in_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: in_svc
description: Timestamp the object enters service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: fault_check
domain_of:
- glm_object
range: string
out_svc:
name: out_svc
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: out_svc
description: Timestamp the object leaves service.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: fault_check
domain_of:
- glm_object
range: string
rank:
name: rank
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: rank
description: Solver rank.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: fault_check
domain_of:
- glm_object
range: string
flags:
name: flags
annotations:
order:
tag: order
value: 0
value_type:
tag: value_type
value: string
native_name:
tag: native_name
value: flags
description: Core object flags.
from_schema: https://gridlabd.org/schema/glm/types/common
rank: 1000
owner: fault_check
domain_of:
- glm_object
range: string