Skip to content

Class: TriplexLoad

Copyright (C) 2013 Battelle Memorial Institute

@file triplex_load.cpp

@addtogroup triplex_load

@ingroup triplex_node

Triplex_load objects represent static loads and export both voltages and

current.

@{

__

Inherits from: triplex_node

__

Type: Instance (network topology element)

URI: glm:TriplexLoad

 classDiagram
    class TriplexLoad
    click TriplexLoad href "../TriplexLoad/"
      TriplexNode <|-- TriplexLoad
        click TriplexNode href "../TriplexNode/"

      TriplexLoad : base_power_1

      TriplexLoad : base_power_12

      TriplexLoad : base_power_2

      TriplexLoad : behaving_as_swing

      TriplexLoad : busflags

      TriplexLoad : bustype





        TriplexLoad --> "0..1" Bustype : bustype
        click Bustype href "../Bustype/"



      TriplexLoad : condition

      TriplexLoad : constant_current_1





        TriplexLoad --> "0..1" Complex : constant_current_1
        click Complex href "../Complex/"



      TriplexLoad : constant_current_12





        TriplexLoad --> "0..1" Complex : constant_current_12
        click Complex href "../Complex/"



      TriplexLoad : constant_current_12_reac

      TriplexLoad : constant_current_12_real

      TriplexLoad : constant_current_1_reac

      TriplexLoad : constant_current_1_real

      TriplexLoad : constant_current_2





        TriplexLoad --> "0..1" Complex : constant_current_2
        click Complex href "../Complex/"



      TriplexLoad : constant_current_2_reac

      TriplexLoad : constant_current_2_real

      TriplexLoad : constant_impedance_1





        TriplexLoad --> "0..1" Complex : constant_impedance_1
        click Complex href "../Complex/"



      TriplexLoad : constant_impedance_12





        TriplexLoad --> "0..1" Complex : constant_impedance_12
        click Complex href "../Complex/"



      TriplexLoad : constant_impedance_12_reac

      TriplexLoad : constant_impedance_12_real

      TriplexLoad : constant_impedance_1_reac

      TriplexLoad : constant_impedance_1_real

      TriplexLoad : constant_impedance_2





        TriplexLoad --> "0..1" Complex : constant_impedance_2
        click Complex href "../Complex/"



      TriplexLoad : constant_impedance_2_reac

      TriplexLoad : constant_impedance_2_real

      TriplexLoad : constant_power_1





        TriplexLoad --> "0..1" Complex : constant_power_1
        click Complex href "../Complex/"



      TriplexLoad : constant_power_12





        TriplexLoad --> "0..1" Complex : constant_power_12
        click Complex href "../Complex/"



      TriplexLoad : constant_power_12_reac

      TriplexLoad : constant_power_12_real

      TriplexLoad : constant_power_1_reac

      TriplexLoad : constant_power_1_real

      TriplexLoad : constant_power_2





        TriplexLoad --> "0..1" Complex : constant_power_2
        click Complex href "../Complex/"



      TriplexLoad : constant_power_2_reac

      TriplexLoad : constant_power_2_real

      TriplexLoad : current_1





        TriplexLoad --> "0..1" Complex : current_1
        click Complex href "../Complex/"



      TriplexLoad : current_12





        TriplexLoad --> "0..1" Complex : current_12
        click Complex href "../Complex/"



      TriplexLoad : current_2





        TriplexLoad --> "0..1" Complex : current_2
        click Complex href "../Complex/"



      TriplexLoad : current_fraction_1

      TriplexLoad : current_fraction_12

      TriplexLoad : current_fraction_2

      TriplexLoad : current_N





        TriplexLoad --> "0..1" Complex : current_N
        click Complex href "../Complex/"



      TriplexLoad : current_pf_1

      TriplexLoad : current_pf_12

      TriplexLoad : current_pf_2

      TriplexLoad : current_uptime

      TriplexLoad : deltamode_full_Y_all_matrix

      TriplexLoad : deltamode_full_Y_matrix

      TriplexLoad : deltamode_generator_current_12





        TriplexLoad --> "0..1" Complex : deltamode_generator_current_12
        click Complex href "../Complex/"



      TriplexLoad : deltamode_PGenTotal





        TriplexLoad --> "0..1" Complex : deltamode_PGenTotal
        click Complex href "../Complex/"



      TriplexLoad : flags

      TriplexLoad : frequency_measure_type





        TriplexLoad --> "0..1" FrequencyMeasureType : frequency_measure_type
        click FrequencyMeasureType href "../FrequencyMeasureType/"



      TriplexLoad : generator_dynamic

      TriplexLoad : GFA_enable

      TriplexLoad : GFA_freq_disconnect_time

      TriplexLoad : GFA_freq_high_trip

      TriplexLoad : GFA_freq_low_trip

      TriplexLoad : GFA_reconnect_time

      TriplexLoad : GFA_status

      TriplexLoad : GFA_trip_method





        TriplexLoad --> "0..1" GfaTripMethod : GFA_trip_method
        click GfaTripMethod href "../GfaTripMethod/"



      TriplexLoad : GFA_volt_disconnect_time

      TriplexLoad : GFA_volt_high_trip

      TriplexLoad : GFA_volt_low_trip

      TriplexLoad : groupid

      TriplexLoad : house_present

      TriplexLoad : impedance_fraction_1

      TriplexLoad : impedance_fraction_12

      TriplexLoad : impedance_fraction_2

      TriplexLoad : impedance_pf_1

      TriplexLoad : impedance_pf_12

      TriplexLoad : impedance_pf_2

      TriplexLoad : in_svc

      TriplexLoad : indiv_measured_power_1





        TriplexLoad --> "0..1" Complex : indiv_measured_power_1
        click Complex href "../Complex/"



      TriplexLoad : indiv_measured_power_12





        TriplexLoad --> "0..1" Complex : indiv_measured_power_12
        click Complex href "../Complex/"



      TriplexLoad : indiv_measured_power_2





        TriplexLoad --> "0..1" Complex : indiv_measured_power_2
        click Complex href "../Complex/"



      TriplexLoad : inrush_integration_method

      TriplexLoad : latitude

      TriplexLoad : load_class





        TriplexLoad --> "0..1" LoadClass : load_class
        click LoadClass href "../LoadClass/"



      TriplexLoad : load_priority





        TriplexLoad --> "0..1" LoadPriority : load_priority
        click LoadPriority href "../LoadPriority/"



      TriplexLoad : longitude

      TriplexLoad : maximum_voltage_error

      TriplexLoad : measured_angle_1

      TriplexLoad : measured_angle_12

      TriplexLoad : measured_angle_2

      TriplexLoad : measured_frequency

      TriplexLoad : measured_frequency_1

      TriplexLoad : measured_frequency_12

      TriplexLoad : measured_frequency_2

      TriplexLoad : measured_power





        TriplexLoad --> "0..1" Complex : measured_power
        click Complex href "../Complex/"



      TriplexLoad : measured_voltage_1





        TriplexLoad --> "0..1" Complex : measured_voltage_1
        click Complex href "../Complex/"



      TriplexLoad : measured_voltage_12





        TriplexLoad --> "0..1" Complex : measured_voltage_12
        click Complex href "../Complex/"



      TriplexLoad : measured_voltage_2





        TriplexLoad --> "0..1" Complex : measured_voltage_2
        click Complex href "../Complex/"



      TriplexLoad : name

      TriplexLoad : nominal_voltage

      TriplexLoad : Norton_dynamic

      TriplexLoad : Norton_dynamic_child

      TriplexLoad : NR_powerflow_parent

      TriplexLoad : out_svc

      TriplexLoad : parent

      TriplexLoad : phases

      TriplexLoad : pll_Ki

      TriplexLoad : pll_Kp

      TriplexLoad : power_1





        TriplexLoad --> "0..1" Complex : power_1
        click Complex href "../Complex/"



      TriplexLoad : power_12





        TriplexLoad --> "0..1" Complex : power_12
        click Complex href "../Complex/"



      TriplexLoad : power_2





        TriplexLoad --> "0..1" Complex : power_2
        click Complex href "../Complex/"



      TriplexLoad : power_fraction_1

      TriplexLoad : power_fraction_12

      TriplexLoad : power_fraction_2

      TriplexLoad : power_pf_1

      TriplexLoad : power_pf_12

      TriplexLoad : power_pf_2

      TriplexLoad : prerotated_current_1





        TriplexLoad --> "0..1" Complex : prerotated_current_1
        click Complex href "../Complex/"



      TriplexLoad : prerotated_current_12





        TriplexLoad --> "0..1" Complex : prerotated_current_12
        click Complex href "../Complex/"



      TriplexLoad : prerotated_current_2





        TriplexLoad --> "0..1" Complex : prerotated_current_2
        click Complex href "../Complex/"



      TriplexLoad : previous_uptime

      TriplexLoad : rank

      TriplexLoad : reference_bus

      TriplexLoad : reset_disabled_island_state

      TriplexLoad : residential_nominal_current_1





        TriplexLoad --> "0..1" Complex : residential_nominal_current_1
        click Complex href "../Complex/"



      TriplexLoad : residential_nominal_current_12





        TriplexLoad --> "0..1" Complex : residential_nominal_current_12
        click Complex href "../Complex/"



      TriplexLoad : residential_nominal_current_12_imag

      TriplexLoad : residential_nominal_current_12_real

      TriplexLoad : residential_nominal_current_1_imag

      TriplexLoad : residential_nominal_current_1_real

      TriplexLoad : residential_nominal_current_2





        TriplexLoad --> "0..1" Complex : residential_nominal_current_2
        click Complex href "../Complex/"



      TriplexLoad : residential_nominal_current_2_imag

      TriplexLoad : residential_nominal_current_2_real

      TriplexLoad : service_status





        TriplexLoad --> "0..1" ServiceStatus : service_status
        click ServiceStatus href "../ServiceStatus/"



      TriplexLoad : service_status_double

      TriplexLoad : sfm_Tf

      TriplexLoad : shunt_1





        TriplexLoad --> "0..1" Complex : shunt_1
        click Complex href "../Complex/"



      TriplexLoad : shunt_12





        TriplexLoad --> "0..1" Complex : shunt_12
        click Complex href "../Complex/"



      TriplexLoad : shunt_2





        TriplexLoad --> "0..1" Complex : shunt_2
        click Complex href "../Complex/"



      TriplexLoad : solution

      TriplexLoad : topological_parent

      TriplexLoad : voltage_1





        TriplexLoad --> "0..1" Complex : voltage_1
        click Complex href "../Complex/"



      TriplexLoad : voltage_12





        TriplexLoad --> "0..1" Complex : voltage_12
        click Complex href "../Complex/"



      TriplexLoad : voltage_1N





        TriplexLoad --> "0..1" Complex : voltage_1N
        click Complex href "../Complex/"



      TriplexLoad : voltage_2





        TriplexLoad --> "0..1" Complex : voltage_2
        click Complex href "../Complex/"



      TriplexLoad : voltage_2N





        TriplexLoad --> "0..1" Complex : voltage_2N
        click Complex href "../Complex/"



      TriplexLoad : voltage_N





        TriplexLoad --> "0..1" Complex : voltage_N
        click Complex href "../Complex/"



Inheritance

Slots

Name Cardinality and Range Description Inheritance
load_class 0..1
LoadClass
Flag to track load type, not currently used for anything except sorting direct
load_priority 0..1
LoadPriority
Load classification based on priority direct
constant_power_1 0..1
Complex
constant power load on split phase 1, specified as VA direct
constant_power_2 0..1
Complex
constant power load on split phase 2, specified as VA direct
constant_power_12 0..1
Complex
constant power load on split phase 12, specified as VA direct
constant_power_1_real 0..1
Float
constant power load on spit phase 1, real only, specified as W direct
constant_power_2_real 0..1
Float
constant power load on phase 2, real only, specified as W direct
constant_power_12_real 0..1
Float
constant power load on phase 12, real only, specified as W direct
constant_power_1_reac 0..1
Float
constant power load on phase 1, imaginary only, specified as VAr direct
constant_power_2_reac 0..1
Float
constant power load on phase 2, imaginary only, specified as VAr direct
constant_power_12_reac 0..1
Float
constant power load on phase 12, imaginary only, specified as VAr direct
constant_current_1 0..1
Complex
constant current load on phase 1, specified as Amps direct
constant_current_2 0..1
Complex
constant current load on phase 2, specified as Amps direct
constant_current_12 0..1
Complex
constant current load on phase 12, specified as Amps direct
constant_current_1_real 0..1
Float
constant current load on phase 1, real only, specified as Amps direct
constant_current_2_real 0..1
Float
constant current load on phase 2, real only, specified as Amps direct
constant_current_12_real 0..1
Float
constant current load on phase 12, real only, specified as Amps direct
constant_current_1_reac 0..1
Float
constant current load on phase 1, imaginary only, specified as Amps direct
constant_current_2_reac 0..1
Float
constant current load on phase 2, imaginary only, specified as Amps direct
constant_current_12_reac 0..1
Float
constant current load on phase 12, imaginary only, specified as Amps direct
constant_impedance_1 0..1
Complex
constant impedance load on phase 1, specified as Ohms direct
constant_impedance_2 0..1
Complex
constant impedance load on phase 2, specified as Ohms direct
constant_impedance_12 0..1
Complex
constant impedance load on phase 12, specified as Ohms direct
constant_impedance_1_real 0..1
Float
constant impedance load on phase 1, real only, specified as Ohms direct
constant_impedance_2_real 0..1
Float
constant impedance load on phase 2, real only, specified as Ohms direct
constant_impedance_12_real 0..1
Float
constant impedance load on phase 12, real only, specified as Ohms direct
constant_impedance_1_reac 0..1
Float
constant impedance load on phase 1, imaginary only, specified as Ohms direct
constant_impedance_2_reac 0..1
Float
constant impedance load on phase 2, imaginary only, specified as Ohms direct
constant_impedance_12_reac 0..1
Float
constant impedance load on phase 12, imaginary only, specified as Ohms direct
measured_voltage_1 0..1
Complex
measured voltage on phase 1 direct
measured_voltage_2 0..1
Complex
measured voltage on phase 2 direct
measured_voltage_12 0..1
Complex
measured voltage on phase 12 direct
indiv_measured_power_1 0..1
Complex
current measured power on phase 1 direct
indiv_measured_power_2 0..1
Complex
current measured power on phase 2 direct
indiv_measured_power_12 0..1
Complex
current measured power on phase 12 direct
measured_power 0..1
Complex
current total measured power direct
base_power_1 0..1
Float
in similar format as ZIPload, this represents the nominal power on phase 1 be... direct
base_power_2 0..1
Float
in similar format as ZIPload, this represents the nominal power on phase 2 be... direct
base_power_12 0..1
Float
in similar format as ZIPload, this represents the nominal power on phase 12 b... direct
power_pf_1 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 1 constan... direct
current_pf_1 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 1 constan... direct
impedance_pf_1 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 1 constan... direct
power_pf_2 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 2 constan... direct
current_pf_2 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 2 constan... direct
impedance_pf_2 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 2 constan... direct
power_pf_12 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 12 consta... direct
current_pf_12 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 12 consta... direct
impedance_pf_12 0..1
Float
in similar format as ZIPload, this is the power factor of the phase 12 consta... direct
power_fraction_1 0..1
Float
this is the constant power fraction of base power on phase 1 direct
current_fraction_1 0..1
Float
this is the constant current fraction of base power on phase 1 direct
impedance_fraction_1 0..1
Float
this is the constant impedance fraction of base power on phase 1 direct
power_fraction_2 0..1
Float
this is the constant power fraction of base power on phase 2 direct
current_fraction_2 0..1
Float
this is the constant current fraction of base power on phase 2 direct
impedance_fraction_2 0..1
Float
this is the constant impedance fraction of base power on phase 2 direct
power_fraction_12 0..1
Float
this is the constant power fraction of base power on phase 12 direct
current_fraction_12 0..1
Float
this is the constant current fraction of base power on phase 12 direct
impedance_fraction_12 0..1
Float
this is the constant impedance fraction of base power on phase 12 direct
bustype 0..1
Bustype
defines whether the node is a PQ, PV, or SWING node TriplexNode
busflags 0..1
String
flag indicates node has a source for voltage, i TriplexNode
reference_bus 0..1
String
reference bus from which frequency is defined TriplexNode
maximum_voltage_error 0..1
Float
convergence voltage limit or convergence criteria TriplexNode
voltage_1 0..1
Complex
bus voltage, phase 1 to ground TriplexNode
voltage_2 0..1
Complex
bus voltage, phase 2 to ground TriplexNode
voltage_N 0..1
Complex
bus voltage, phase N to ground TriplexNode
voltage_12 0..1
Complex
bus voltage, phase 1 to 2 TriplexNode
voltage_1N 0..1
Complex
bus voltage, phase 1 to N TriplexNode
voltage_2N 0..1
Complex
bus voltage, phase 2 to N TriplexNode
prerotated_current_1 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... TriplexNode
prerotated_current_2 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... TriplexNode
prerotated_current_12 0..1
Complex
deltamode-functionality - bus current injection (in = positive), but will not... TriplexNode
deltamode_generator_current_12 0..1
Complex
deltamode-functionality - bus current injection (in = positive), direct gener... TriplexNode
deltamode_PGenTotal 0..1
Complex
deltamode-functionality - power value for a diesel generator -- accumulator o... TriplexNode
deltamode_full_Y_matrix 0..1
String
deltamode-functionality full_Y matrix exposes so generator objects can intera... TriplexNode
deltamode_full_Y_all_matrix 0..1
String
deltamode-functionality full_Y_all matrix exposes so generator objects can in... TriplexNode
NR_powerflow_parent 0..1
String
NR powerflow - actual powerflow parent - used by generators accessing child o... TriplexNode
residential_nominal_current_1 0..1
Complex
posted current on phase 1 from a residential object, if attached TriplexNode
residential_nominal_current_2 0..1
Complex
posted current on phase 2 from a residential object, if attached TriplexNode
residential_nominal_current_12 0..1
Complex
posted current on phase 1 to 2 from a residential object, if attached TriplexNode
residential_nominal_current_1_real 0..1
Float
posted current on phase 1, real, from a residential object, if attached TriplexNode
residential_nominal_current_1_imag 0..1
Float
posted current on phase 1, imag, from a residential object, if attached TriplexNode
residential_nominal_current_2_real 0..1
Float
posted current on phase 2, real, from a residential object, if attached TriplexNode
residential_nominal_current_2_imag 0..1
Float
posted current on phase 2, imag, from a residential object, if attached TriplexNode
residential_nominal_current_12_real 0..1
Float
posted current on phase 1 to 2, real, from a residential object, if attached TriplexNode
residential_nominal_current_12_imag 0..1
Float
posted current on phase 1 to 2, imag, from a residential object, if attached TriplexNode
current_1 0..1
Complex
accumulator - used for debugging/interfacing only - current load on phase 1 TriplexNode
current_2 0..1
Complex
accumulator - used for debugging/interfacing only - current load on phase 2 TriplexNode
current_N 0..1
Complex
accumulator - used for debugging/interfacing only - current load on phase N TriplexNode
current_12 0..1
Complex
accumulator - used for debugging/interfacing only - current load on phase 1 t... TriplexNode
power_1 0..1
Complex
accumulator - used for debugging/interfacing only - power on phase 1 (120V) TriplexNode
power_2 0..1
Complex
accumulator - used for debugging/interfacing only - power on phase 2 (120V) TriplexNode
power_12 0..1
Complex
accumulator - used for debugging/interfacing only - power on phase 1 to 2 (24... TriplexNode
shunt_1 0..1
Complex
accumulator - used for debugging/interfacing only - shunt impedance on phase ... TriplexNode
shunt_2 0..1
Complex
accumulator - used for debugging/interfacing only - shunt impedance on phase ... TriplexNode
shunt_12 0..1
Complex
accumulator - used for debugging/interfacing only - shunt impedance on phase ... TriplexNode
house_present 0..1
Boolean
boolean for detecting whether a house is attached, not an input TriplexNode
Norton_dynamic 0..1
Boolean
Flag to indicate a Norton-equivalent connection -- used for generators and de... TriplexNode
Norton_dynamic_child 0..1
Boolean
Flag to indicate a Norton-equivalent connection is made by a childed node obj... TriplexNode
generator_dynamic 0..1
Boolean
Flag to indicate a voltage-sourcing or swing-type generator is present -- use... TriplexNode
reset_disabled_island_state 0..1
Boolean
Deltamode/multi-island flag -- used to reset disabled status (and reform an i... TriplexNode
GFA_enable 0..1
Boolean
Disable/Enable Grid Friendly Applicance(TM)-type functionality TriplexNode
GFA_freq_low_trip 0..1
Float
Low frequency trip point for Grid Friendly Appliance(TM)-type functionality TriplexNode
GFA_freq_high_trip 0..1
Float
High frequency trip point for Grid Friendly Appliance(TM)-type functionality TriplexNode
GFA_volt_low_trip 0..1
Float
Low voltage trip point for Grid Friendly Appliance(TM)-type functionality TriplexNode
GFA_volt_high_trip 0..1
Float
High voltage trip point for Grid Friendly Appliance(TM)-type functionality TriplexNode
GFA_reconnect_time 0..1
Float
Reconnect time for Grid Friendly Appliance(TM)-type functionality TriplexNode
GFA_freq_disconnect_time 0..1
Float
Frequency violation disconnect time for Grid Friendly Appliance(TM)-type func... TriplexNode
GFA_volt_disconnect_time 0..1
Float
Voltage violation disconnect time for Grid Friendly Appliance(TM)-type functi... TriplexNode
GFA_status 0..1
Boolean
Low frequency trip point for Grid Friendly Appliance(TM)-type functionality TriplexNode
GFA_trip_method 0..1
GfaTripMethod
GFA trip for over-voltage TriplexNode
service_status 0..1
ServiceStatus
In and out of service flag TriplexNode
service_status_double 0..1
Float
In and out of service flag - type double - will indiscriminately override ser... TriplexNode
previous_uptime 0..1
Float
Previous time between disconnects of node in minutes TriplexNode
current_uptime 0..1
Float
Current time since last disconnect of node in minutes TriplexNode
topological_parent 0..1
String
topological parent as per GLM configuration TriplexNode
behaving_as_swing 0..1
Boolean
Indicator flag for if a bus is behaving as a reference voltage source - valid... TriplexNode
frequency_measure_type 0..1
FrequencyMeasureType
PLL frequency measurement TriplexNode
sfm_Tf 0..1
Float
Transducer time constant for simplified frequency measurement (seconds) TriplexNode
pll_Kp 0..1
Float
Proportional gain of PLL frequency measurement TriplexNode
pll_Ki 0..1
Float
Integration gain of PLL frequency measurement TriplexNode
measured_angle_1 0..1
Float
bus angle measurement, phase 1N TriplexNode
measured_frequency_1 0..1
Float
frequency measurement, phase 1N TriplexNode
measured_angle_2 0..1
Float
bus angle measurement, phase 2N TriplexNode
measured_frequency_2 0..1
Float
frequency measurement, phase 2N TriplexNode
measured_angle_12 0..1
Float
bus angle measurement, across the phases TriplexNode
measured_frequency_12 0..1
Float
frequency measurement, across the phases TriplexNode
measured_frequency 0..1
Float
frequency measurement - average of present phases TriplexNode
phases 0..1
String
PowerflowObject
nominal_voltage 0..1
Float
PowerflowObject
inrush_integration_method 0..1
String
Integration method for in-rush PowerflowObject
condition 0..1
String
PowerflowObject
solution 0..1
String
PowerflowObject
name 1
String
The object's name; unique across the model GlmObject
parent 0..1
String
The parent object's name GlmObject
groupid 0..1
String
Free-text group label GlmObject
latitude 0..1
String
Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form) GlmObject
longitude 0..1
String
Longitude, as written GlmObject
in_svc 0..1
String
Timestamp the object enters service GlmObject
out_svc 0..1
String
Timestamp the object leaves service GlmObject
rank 0..1
String
Solver rank GlmObject
flags 0..1
String
Core object flags GlmObject

Comments

  • Import: EnergyConsumer on s1, s2 (the legs 1, 2), mRID ld_ + name, and the 240 V part 12 as a second delta EnergyConsumer ld_ + name + _12 (triplex_load.cimtbl); a ConformLoad of the group when the base reads a player or schedule. Export: EnergyConsumer, ConformLoad and NonConformLoad on a split-phase bus: a wye one as the legs, a delta one as the 240 V part (a _12 delta next to is its 12 again).

Identifier and Mapping Information

Schema Source

  • from schema: https://gridlabd.org/schema/glm

Mappings

Mapping Type Mapped Value
self glm:TriplexLoad
native glm:TriplexLoad
exact cim:EnergyConsumer
close cim:ConformLoad

LinkML Source

Direct

name: triplex_load
description: 'Copyright (C) 2013 Battelle Memorial Institute

  @file triplex_load.cpp

  @addtogroup triplex_load

  @ingroup triplex_node

  Triplex_load objects represent static loads and export both voltages and

  current.

  @{


  Inherits from: triplex_node


  Type: Instance (network topology element)'
comments:
- 'Import: EnergyConsumer on s1, s2 (the legs 1, 2), mRID ld_ + name, and the 240
  V part 12 as a second delta EnergyConsumer ld_ + name + _12 (triplex_load.cimtbl);
  a ConformLoad of the group when the base reads a player or schedule. Export: EnergyConsumer,
  ConformLoad and NonConformLoad on a split-phase bus: a wye one as the legs, a delta
  one as the 240 V part (a <name>_12 delta next to <name> is its 12 again).'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:EnergyConsumer
close_mappings:
- cim:ConformLoad
is_a: triplex_node
attributes:
  load_class:
    name: load_class
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: load_class
    description: Flag to track load type, not currently used for anything except sorting
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    domain_of:
    - load
    - triplex_load
    range: LoadClass
    required: false
  load_priority:
    name: load_priority
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: load_priority
    description: Load classification based on priority
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    domain_of:
    - load
    - triplex_load
    range: LoadPriority
    required: false
  constant_power_1:
    name: constant_power_1
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_1[VA]
    description: constant power load on split phase 1, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_2:
    name: constant_power_2
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_2[VA]
    description: constant power load on split phase 2, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_12:
    name: constant_power_12
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_12[VA]
    description: constant power load on split phase 12, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_1_real:
    name: constant_power_1_real
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_1_real[W]
    description: constant power load on spit phase 1, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_2_real:
    name: constant_power_2_real
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_2_real[W]
    description: constant power load on phase 2, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_12_real:
    name: constant_power_12_real
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_12_real[W]
    description: constant power load on phase 12, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_1_reac:
    name: constant_power_1_reac
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_1_reac[VAr]
    description: constant power load on phase 1, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_2_reac:
    name: constant_power_2_reac
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_2_reac[VAr]
    description: constant power load on phase 2, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_12_reac:
    name: constant_power_12_reac
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_12_reac[VAr]
    description: constant power load on phase 12, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_current_1:
    name: constant_current_1
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_1[A]
    description: constant current load on phase 1, specified as Amps
    comments:
    - 'Import: raises when set, as every explicit constant_current and constant_impedance
      form (_real, _reac). Export: not written; the base_power form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_2:
    name: constant_current_2
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_2[A]
    description: constant current load on phase 2, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_12:
    name: constant_current_12
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_12[A]
    description: constant current load on phase 12, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_1_real:
    name: constant_current_1_real
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_1_real[A]
    description: constant current load on phase 1, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_2_real:
    name: constant_current_2_real
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_2_real[A]
    description: constant current load on phase 2, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_12_real:
    name: constant_current_12_real
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_12_real[A]
    description: constant current load on phase 12, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_1_reac:
    name: constant_current_1_reac
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_1_reac[A]
    description: constant current load on phase 1, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_2_reac:
    name: constant_current_2_reac
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_2_reac[A]
    description: constant current load on phase 2, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_12_reac:
    name: constant_current_12_reac
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_12_reac[A]
    description: constant current load on phase 12, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_impedance_1:
    name: constant_impedance_1
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_1[Ohm]
    description: constant impedance load on phase 1, specified as Ohms
    comments:
    - 'Import: raises when set (see constant_current_1). Export: not written; the
      base_power form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_2:
    name: constant_impedance_2
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_2[Ohm]
    description: constant impedance load on phase 2, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_12:
    name: constant_impedance_12
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_12[Ohm]
    description: constant impedance load on phase 12, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_1_real:
    name: constant_impedance_1_real
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_1_real[Ohm]
    description: constant impedance load on phase 1, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_2_real:
    name: constant_impedance_2_real
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_2_real[Ohm]
    description: constant impedance load on phase 2, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_12_real:
    name: constant_impedance_12_real
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_12_real[Ohm]
    description: constant impedance load on phase 12, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_1_reac:
    name: constant_impedance_1_reac
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_1_reac[Ohm]
    description: constant impedance load on phase 1, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_2_reac:
    name: constant_impedance_2_reac
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_2_reac[Ohm]
    description: constant impedance load on phase 2, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_12_reac:
    name: constant_impedance_12_reac
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_12_reac[Ohm]
    description: constant impedance load on phase 12, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  measured_voltage_1:
    name: measured_voltage_1
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_1[V]
    description: measured voltage on phase 1
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_2:
    name: measured_voltage_2
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_2[V]
    description: measured voltage on phase 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_12:
    name: measured_voltage_12
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_12[V]
    description: measured voltage on phase 12
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: V
  indiv_measured_power_1:
    name: indiv_measured_power_1
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: indiv_measured_power_1[VA]
    description: current measured power on phase 1
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  indiv_measured_power_2:
    name: indiv_measured_power_2
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: indiv_measured_power_2[VA]
    description: current measured power on phase 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  indiv_measured_power_12:
    name: indiv_measured_power_12
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: indiv_measured_power_12[VA]
    description: current measured power on phase 12
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power:
    name: measured_power
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power[VA]
    description: current total measured power
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    domain_of:
    - load
    - meter
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  base_power_1:
    name: base_power_1
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_1[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase 1 before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VA
  base_power_2:
    name: base_power_2
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_2[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase 2 before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VA
  base_power_12:
    name: base_power_12
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_12[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase 12 before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VA
  power_pf_1:
    name: power_pf_1
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_1[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      1 constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_1:
    name: current_pf_1
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_1[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      1 constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_1:
    name: impedance_pf_1
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_1[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      1 constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_pf_2:
    name: power_pf_2
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_2[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      2 constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_2:
    name: current_pf_2
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_2[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      2 constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_2:
    name: impedance_pf_2
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_2[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      2 constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_pf_12:
    name: power_pf_12
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_12[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      12 constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_12:
    name: current_pf_12
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_12[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      12 constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_12:
    name: impedance_pf_12
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_12[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      12 constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_1:
    name: power_fraction_1
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_1[pu]
    description: this is the constant power fraction of base power on phase 1
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_1:
    name: current_fraction_1
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_1[pu]
    description: this is the constant current fraction of base power on phase 1
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_1:
    name: impedance_fraction_1
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_1[pu]
    description: this is the constant impedance fraction of base power on phase 1
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_2:
    name: power_fraction_2
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_2[pu]
    description: this is the constant power fraction of base power on phase 2
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_2:
    name: current_fraction_2
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_2[pu]
    description: this is the constant current fraction of base power on phase 2
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_2:
    name: impedance_fraction_2
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_2[pu]
    description: this is the constant impedance fraction of base power on phase 2
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_12:
    name: power_fraction_12
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_12[pu]
    description: this is the constant power fraction of base power on phase 12
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_12:
    name: current_fraction_12
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_12[pu]
    description: this is the constant current fraction of base power on phase 12
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_12:
    name: impedance_fraction_12
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_12[pu]
    description: this is the constant impedance fraction of base power on phase 12
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu

Induced

name: triplex_load
description: 'Copyright (C) 2013 Battelle Memorial Institute

  @file triplex_load.cpp

  @addtogroup triplex_load

  @ingroup triplex_node

  Triplex_load objects represent static loads and export both voltages and

  current.

  @{


  Inherits from: triplex_node


  Type: Instance (network topology element)'
comments:
- 'Import: EnergyConsumer on s1, s2 (the legs 1, 2), mRID ld_ + name, and the 240
  V part 12 as a second delta EnergyConsumer ld_ + name + _12 (triplex_load.cimtbl);
  a ConformLoad of the group when the base reads a player or schedule. Export: EnergyConsumer,
  ConformLoad and NonConformLoad on a split-phase bus: a wye one as the legs, a delta
  one as the 240 V part (a <name>_12 delta next to <name> is its 12 again).'
from_schema: https://gridlabd.org/schema/glm
exact_mappings:
- cim:EnergyConsumer
close_mappings:
- cim:ConformLoad
is_a: triplex_node
attributes:
  load_class:
    name: load_class
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: load_class
    description: Flag to track load type, not currently used for anything except sorting
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    owner: triplex_load
    domain_of:
    - load
    - triplex_load
    range: LoadClass
    required: false
  load_priority:
    name: load_priority
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: load_priority
    description: Load classification based on priority
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    owner: triplex_load
    domain_of:
    - load
    - triplex_load
    range: LoadPriority
    required: false
  constant_power_1:
    name: constant_power_1
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_1[VA]
    description: constant power load on split phase 1, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_2:
    name: constant_power_2
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_2[VA]
    description: constant power load on split phase 2, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_12:
    name: constant_power_12
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_power_12[VA]
    description: constant power load on split phase 12, specified as VA
    comments:
    - 'Import: EnergyConsumer.p (W) and q (VAr), and EnergyConsumerPhase.p, q when
      the phases differ; with base_power it raises. Export: not written; the base_power
      form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  constant_power_1_real:
    name: constant_power_1_real
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_1_real[W]
    description: constant power load on spit phase 1, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_2_real:
    name: constant_power_2_real
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_2_real[W]
    description: constant power load on phase 2, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_12_real:
    name: constant_power_12_real
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_12_real[W]
    description: constant power load on phase 12, real only, specified as W
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: W
  constant_power_1_reac:
    name: constant_power_1_reac
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_1_reac[VAr]
    description: constant power load on phase 1, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_2_reac:
    name: constant_power_2_reac
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_2_reac[VAr]
    description: constant power load on phase 2, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_power_12_reac:
    name: constant_power_12_reac
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_power_12_reac[VAr]
    description: constant power load on phase 12, imaginary only, specified as VAr
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VAr
  constant_current_1:
    name: constant_current_1
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_1[A]
    description: constant current load on phase 1, specified as Amps
    comments:
    - 'Import: raises when set, as every explicit constant_current and constant_impedance
      form (_real, _reac). Export: not written; the base_power form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_2:
    name: constant_current_2
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_2[A]
    description: constant current load on phase 2, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_12:
    name: constant_current_12
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_current_12[A]
    description: constant current load on phase 12, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: A
  constant_current_1_real:
    name: constant_current_1_real
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_1_real[A]
    description: constant current load on phase 1, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_2_real:
    name: constant_current_2_real
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_2_real[A]
    description: constant current load on phase 2, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_12_real:
    name: constant_current_12_real
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_12_real[A]
    description: constant current load on phase 12, real only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_1_reac:
    name: constant_current_1_reac
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_1_reac[A]
    description: constant current load on phase 1, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_2_reac:
    name: constant_current_2_reac
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_2_reac[A]
    description: constant current load on phase 2, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_current_12_reac:
    name: constant_current_12_reac
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_current_12_reac[A]
    description: constant current load on phase 12, imaginary only, specified as Amps
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: A
  constant_impedance_1:
    name: constant_impedance_1
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_1[Ohm]
    description: constant impedance load on phase 1, specified as Ohms
    comments:
    - 'Import: raises when set (see constant_current_1). Export: not written; the
      base_power form is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_2:
    name: constant_impedance_2
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_2[Ohm]
    description: constant impedance load on phase 2, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_12:
    name: constant_impedance_12
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: constant_impedance_12[Ohm]
    description: constant impedance load on phase 12, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_1_real:
    name: constant_impedance_1_real
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_1_real[Ohm]
    description: constant impedance load on phase 1, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_2_real:
    name: constant_impedance_2_real
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_2_real[Ohm]
    description: constant impedance load on phase 2, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_12_real:
    name: constant_impedance_12_real
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_12_real[Ohm]
    description: constant impedance load on phase 12, real only, specified as Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_1_reac:
    name: constant_impedance_1_reac
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_1_reac[Ohm]
    description: constant impedance load on phase 1, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_2_reac:
    name: constant_impedance_2_reac
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_2_reac[Ohm]
    description: constant impedance load on phase 2, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  constant_impedance_12_reac:
    name: constant_impedance_12_reac
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: constant_impedance_12_reac[Ohm]
    description: constant impedance load on phase 12, imaginary only, specified as
      Ohms
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: Ohm
  measured_voltage_1:
    name: measured_voltage_1
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_1[V]
    description: measured voltage on phase 1
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_2:
    name: measured_voltage_2
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_2[V]
    description: measured voltage on phase 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: V
  measured_voltage_12:
    name: measured_voltage_12
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_voltage_12[V]
    description: measured voltage on phase 12
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: V
  indiv_measured_power_1:
    name: indiv_measured_power_1
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: indiv_measured_power_1[VA]
    description: current measured power on phase 1
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  indiv_measured_power_2:
    name: indiv_measured_power_2
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: indiv_measured_power_2[VA]
    description: current measured power on phase 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  indiv_measured_power_12:
    name: indiv_measured_power_12
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: indiv_measured_power_12[VA]
    description: current measured power on phase 12
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: Complex
    required: false
    unit:
      ucum_code: VA
  measured_power:
    name: measured_power
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: measured_power[VA]
    description: current total measured power
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    owner: triplex_load
    domain_of:
    - load
    - meter
    - triplex_load
    - triplex_meter
    range: Complex
    required: false
    unit:
      ucum_code: VA
  base_power_1:
    name: base_power_1
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_1[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase 1 before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VA
  base_power_2:
    name: base_power_2
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_2[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase 2 before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VA
  base_power_12:
    name: base_power_12
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: base_power_12[VA]
    description: in similar format as ZIPload, this represents the nominal power on
      phase 12 before applying ZIP fractions
    comments:
    - 'Import: split by the fractions and power factors at nominal voltage into EnergyConsumer.p
      (W) and q (VAr), and EnergyConsumerPhase.p, q when the phases differ; <player>.value*K
      or <schedule>*K is K and makes a ConformLoad of the group. Export: the sum of
      |S| of the ZIP parts of the phase''s p and q, <player>.value*base on a scheduled
      ConformLoad.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: VA
  power_pf_1:
    name: power_pf_1
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_1[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      1 constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_1:
    name: current_pf_1
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_1[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      1 constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_1:
    name: impedance_pf_1
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_1[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      1 constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_pf_2:
    name: power_pf_2
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_2[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      2 constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_2:
    name: current_pf_2
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_2[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      2 constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_2:
    name: impedance_pf_2
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_2[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      2 constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_pf_12:
    name: power_pf_12
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_pf_12[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      12 constant power portion of load
    comments:
    - 'Import: with base_power, sets the power part''s q from its p (default 1; pf
      0 is all Q). Export: P/|S| of the power part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_pf_12:
    name: current_pf_12
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_pf_12[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      12 constant current portion of load
    comments:
    - 'Import: with base_power, sets the current part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the current part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_pf_12:
    name: impedance_pf_12
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_pf_12[pu]
    description: in similar format as ZIPload, this is the power factor of the phase
      12 constant impedance portion of load
    comments:
    - 'Import: with base_power, sets the impedance part''s q from its p (default 1;
      pf 0 is all Q). Export: P/|S| of the impedance part, negative when its Q is.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_1:
    name: power_fraction_1
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_1[pu]
    description: this is the constant power fraction of base power on phase 1
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_1:
    name: current_fraction_1
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_1[pu]
    description: this is the constant current fraction of base power on phase 1
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_1:
    name: impedance_fraction_1
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_1[pu]
    description: this is the constant impedance fraction of base power on phase 1
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_2:
    name: power_fraction_2
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_2[pu]
    description: this is the constant power fraction of base power on phase 2
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_2:
    name: current_fraction_2
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_2[pu]
    description: this is the constant current fraction of base power on phase 2
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_2:
    name: impedance_fraction_2
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_2[pu]
    description: this is the constant impedance fraction of base power on phase 2
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  power_fraction_12:
    name: power_fraction_12
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: power_fraction_12[pu]
    description: this is the constant power fraction of base power on phase 12
    comments:
    - 'Import: with base_power, the power part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant power row or a zip_ LoadResponseCharacteristic row (p/qConstantPower);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the power part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantPower
    - cim:LoadResponseCharacteristic.qConstantPower
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  current_fraction_12:
    name: current_fraction_12
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_fraction_12[pu]
    description: this is the constant current fraction of base power on phase 12
    comments:
    - 'Import: with base_power, the current part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant current row or a zip_ LoadResponseCharacteristic row (p/qConstantCurrent);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the current part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantCurrent
    - cim:LoadResponseCharacteristic.qConstantCurrent
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  impedance_fraction_12:
    name: impedance_fraction_12
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: impedance_fraction_12[pu]
    description: this is the constant impedance fraction of base power on phase 12
    comments:
    - 'Import: with base_power, the impedance part''s share of p and q makes EnergyConsumer.LoadResponse,
      the shared constant impedance row or a zip_ LoadResponseCharacteristic row (p/qConstantImpedance);
      default 0, and the power fraction is 1 - I - Z when they do not sum to 1. Export:
      |S| of the impedance part over base_power, from get_load_response.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_load
    close_mappings:
    - cim:LoadResponseCharacteristic.pConstantImpedance
    - cim:LoadResponseCharacteristic.qConstantImpedance
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_load
    range: float
    required: false
    unit:
      ucum_code: pu
  bustype:
    name: bustype
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: bustype
    description: defines whether the node is a PQ, PV, or SWING node
    comments:
    - 'Import: SWING makes an EnergySource; the rest are a plain bus. Export: not
      written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    related_mappings:
    - cim:EnergySource
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: Bustype
    required: false
  busflags:
    name: busflags
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: busflags
    description: flag indicates node has a source for voltage, i.e. connects to the
      swing node
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  reference_bus:
    name: reference_bus
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: reference_bus
    description: reference bus from which frequency is defined
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  maximum_voltage_error:
    name: maximum_voltage_error
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: maximum_voltage_error[V]
    description: convergence voltage limit or convergence criteria
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: V
  voltage_1:
    name: voltage_1
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_1[V]
    description: bus voltage, phase 1 to ground
    comments:
    - 'Import: on a SWING bus only: EnergySource.voltageMagnitude (line to line) and
      voltageAngle (deg); elsewhere the solver guess, not converted. Export: not written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    close_mappings:
    - cim:EnergySource.voltageMagnitude
    - cim:EnergySource.voltageAngle
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_2:
    name: voltage_2
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_2[V]
    description: bus voltage, phase 2 to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_N:
    name: voltage_N
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_N[V]
    description: bus voltage, phase N to ground
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_12:
    name: voltage_12
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_12[V]
    description: bus voltage, phase 1 to 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_1N:
    name: voltage_1N
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_1N[V]
    description: bus voltage, phase 1 to N
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  voltage_2N:
    name: voltage_2N
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: voltage_2N[V]
    description: bus voltage, phase 2 to N
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    - windturb_dg
    - house
    range: Complex
    required: false
    unit:
      ucum_code: V
  prerotated_current_1:
    name: prerotated_current_1
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_1[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_2:
    name: prerotated_current_2
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_2[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  prerotated_current_12:
    name: prerotated_current_12
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: prerotated_current_12[A]
    description: deltamode-functionality - bus current injection (in = positive),
      but will not be rotated by powerflow for off-nominal frequency, this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_generator_current_12:
    name: deltamode_generator_current_12
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_generator_current_12[A]
    description: deltamode-functionality - bus current injection (in = positive),
      direct generator injection (so may be overwritten internally), this an accumulator
      only, not a output or input variable
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  deltamode_PGenTotal:
    name: deltamode_PGenTotal
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: deltamode_PGenTotal
    description: deltamode-functionality - power value for a diesel generator -- accumulator
      only, not an output or input
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: Complex
    required: false
  deltamode_full_Y_matrix:
    name: deltamode_full_Y_matrix
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_matrix
    description: deltamode-functionality full_Y matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  deltamode_full_Y_all_matrix:
    name: deltamode_full_Y_all_matrix
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: deltamode_full_Y_all_matrix
    description: deltamode-functionality full_Y_all matrix exposes so generator objects
      can interact for Norton equivalents
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  NR_powerflow_parent:
    name: NR_powerflow_parent
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: NR_powerflow_parent
    description: NR powerflow - actual powerflow parent - used by generators accessing
      child objects
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  residential_nominal_current_1:
    name: residential_nominal_current_1
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_1[A]
    description: posted current on phase 1 from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_2:
    name: residential_nominal_current_2
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_2[A]
    description: posted current on phase 2 from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_12:
    name: residential_nominal_current_12
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: residential_nominal_current_12[A]
    description: posted current on phase 1 to 2 from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_1_real:
    name: residential_nominal_current_1_real
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_1_real[A]
    description: posted current on phase 1, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_1_imag:
    name: residential_nominal_current_1_imag
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_1_imag[A]
    description: posted current on phase 1, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_2_real:
    name: residential_nominal_current_2_real
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_2_real[A]
    description: posted current on phase 2, real, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_2_imag:
    name: residential_nominal_current_2_imag
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_2_imag[A]
    description: posted current on phase 2, imag, from a residential object, if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_12_real:
    name: residential_nominal_current_12_real
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_12_real[A]
    description: posted current on phase 1 to 2, real, from a residential object,
      if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: A
  residential_nominal_current_12_imag:
    name: residential_nominal_current_12_imag
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: residential_nominal_current_12_imag[A]
    description: posted current on phase 1 to 2, imag, from a residential object,
      if attached
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: A
  current_1:
    name: current_1
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_1[A]
    description: accumulator - used for debugging/interfacing only - current load
      on phase 1
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_2:
    name: current_2
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_2[A]
    description: accumulator - used for debugging/interfacing only - current load
      on phase 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_N:
    name: current_N
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_N[A]
    description: accumulator - used for debugging/interfacing only - current load
      on phase N
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: A
  current_12:
    name: current_12
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: current_12[A]
    description: accumulator - used for debugging/interfacing only - current load
      on phase 1 to 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: A
  power_1:
    name: power_1
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_1[VA]
    description: accumulator - used for debugging/interfacing only - power on phase
      1 (120V)
    comments:
    - 'Import: EnergyConsumer.p, q (W, VAr as written) of the ld_ + name consumer
      on s1, s2, and EnergyConsumerPhase.p, q (s1) when the legs differ. Export: not
      written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_2:
    name: power_2
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_2[VA]
    description: accumulator - used for debugging/interfacing only - power on phase
      2 (120V)
    comments:
    - 'Import: EnergyConsumer.p, q (W, VAr as written) of the ld_ + name consumer
      on s1, s2, and EnergyConsumerPhase.p, q (s2) when the legs differ. Export: not
      written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    - cim:EnergyConsumerPhase.p
    - cim:EnergyConsumerPhase.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: VA
  power_12:
    name: power_12
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: power_12[VA]
    description: accumulator - used for debugging/interfacing only - power on phase
      1 to 2 (240V)
    comments:
    - 'Import: EnergyConsumer.p, q (W, VAr as written) of the delta consumer on s1s2,
      mRID ld_ + name + _12. Export: not written.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    close_mappings:
    - cim:EnergyConsumer.p
    - cim:EnergyConsumer.q
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    - windturb_dg
    range: Complex
    required: false
    unit:
      ucum_code: VA
  shunt_1:
    name: shunt_1
    annotations:
      order:
        tag: order
        value: 35
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_1[S]
    description: accumulator - used for debugging/interfacing only - shunt impedance
      on phase 1
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_2:
    name: shunt_2
    annotations:
      order:
        tag: order
        value: 36
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_2[S]
    description: accumulator - used for debugging/interfacing only - shunt impedance
      on phase 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: S
  shunt_12:
    name: shunt_12
    annotations:
      order:
        tag: order
        value: 37
      value_type:
        tag: value_type
        value: complex
      native_name:
        tag: native_name
        value: shunt_12[S]
    description: accumulator - used for debugging/interfacing only - shunt impedance
      on phase 1 to 2
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: Complex
    required: false
    unit:
      ucum_code: S
  house_present:
    name: house_present
    annotations:
      order:
        tag: order
        value: 38
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: house_present
    description: boolean for detecting whether a house is attached, not an input
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  Norton_dynamic:
    name: Norton_dynamic
    annotations:
      order:
        tag: order
        value: 39
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic
    description: Flag to indicate a Norton-equivalent connection -- used for generators
      and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  Norton_dynamic_child:
    name: Norton_dynamic_child
    annotations:
      order:
        tag: order
        value: 40
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: Norton_dynamic_child
    description: Flag to indicate a Norton-equivalent connection is made by a childed
      node object -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  generator_dynamic:
    name: generator_dynamic
    annotations:
      order:
        tag: order
        value: 41
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: generator_dynamic
    description: Flag to indicate a voltage-sourcing or swing-type generator is present
      -- used for generators and deltamode
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  reset_disabled_island_state:
    name: reset_disabled_island_state
    annotations:
      order:
        tag: order
        value: 42
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: reset_disabled_island_state
    description: Deltamode/multi-island flag -- used to reset disabled status (and
      reform an island)
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_enable:
    name: GFA_enable
    annotations:
      order:
        tag: order
        value: 43
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_enable
    description: Disable/Enable Grid Friendly Applicance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_freq_low_trip:
    name: GFA_freq_low_trip
    annotations:
      order:
        tag: order
        value: 44
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_low_trip[Hz]
    description: Low frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_freq_high_trip:
    name: GFA_freq_high_trip
    annotations:
      order:
        tag: order
        value: 45
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_high_trip[Hz]
    description: High frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  GFA_volt_low_trip:
    name: GFA_volt_low_trip
    annotations:
      order:
        tag: order
        value: 46
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_low_trip[pu]
    description: Low voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_volt_high_trip:
    name: GFA_volt_high_trip
    annotations:
      order:
        tag: order
        value: 47
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_high_trip[pu]
    description: High voltage trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  GFA_reconnect_time:
    name: GFA_reconnect_time
    annotations:
      order:
        tag: order
        value: 48
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_reconnect_time[s]
    description: Reconnect time for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_freq_disconnect_time:
    name: GFA_freq_disconnect_time
    annotations:
      order:
        tag: order
        value: 49
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_freq_disconnect_time[s]
    description: Frequency violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_volt_disconnect_time:
    name: GFA_volt_disconnect_time
    annotations:
      order:
        tag: order
        value: 50
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: GFA_volt_disconnect_time[s]
    description: Voltage violation disconnect time for Grid Friendly Appliance(TM)-type
      functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  GFA_status:
    name: GFA_status
    annotations:
      order:
        tag: order
        value: 51
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: GFA_status
    description: Low frequency trip point for Grid Friendly Appliance(TM)-type functionality
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  GFA_trip_method:
    name: GFA_trip_method
    annotations:
      order:
        tag: order
        value: 52
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: GFA_trip_method
    description: GFA trip for over-voltage
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: GfaTripMethod
    required: false
  service_status:
    name: service_status
    annotations:
      order:
        tag: order
        value: 53
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: service_status
    description: In and out of service flag
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: ServiceStatus
    required: false
  service_status_double:
    name: service_status_double
    annotations:
      order:
        tag: order
        value: 54
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: service_status_double
    description: In and out of service flag - type double - will indiscriminately
      override service_status - useful for schedules
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
  previous_uptime:
    name: previous_uptime
    annotations:
      order:
        tag: order
        value: 55
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: previous_uptime[min]
    description: Previous time between disconnects of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  current_uptime:
    name: current_uptime
    annotations:
      order:
        tag: order
        value: 56
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: current_uptime[min]
    description: Current time since last disconnect of node in minutes
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: min
  topological_parent:
    name: topological_parent
    annotations:
      order:
        tag: order
        value: 57
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: topological_parent
    description: topological parent as per GLM configuration
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: string
    required: false
  behaving_as_swing:
    name: behaving_as_swing
    annotations:
      order:
        tag: order
        value: 58
      value_type:
        tag: value_type
        value: bool
      native_name:
        tag: native_name
        value: behaving_as_swing
    description: Indicator flag for if a bus is behaving as a reference voltage source
      - valid for a SWING or SWING_PQ
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: boolean
    required: false
  frequency_measure_type:
    name: frequency_measure_type
    annotations:
      order:
        tag: order
        value: 59
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: frequency_measure_type
    description: PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: FrequencyMeasureType
    required: false
  sfm_Tf:
    name: sfm_Tf
    annotations:
      order:
        tag: order
        value: 60
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: sfm_Tf[s]
    description: Transducer time constant for simplified frequency measurement (seconds)
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: s
  pll_Kp:
    name: pll_Kp
    annotations:
      order:
        tag: order
        value: 61
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Kp[pu]
    description: Proportional gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  pll_Ki:
    name: pll_Ki
    annotations:
      order:
        tag: order
        value: 62
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: pll_Ki[pu]
    description: Integration gain of PLL frequency measurement
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: pu
  measured_angle_1:
    name: measured_angle_1
    annotations:
      order:
        tag: order
        value: 63
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_1[rad]
    description: bus angle measurement, phase 1N
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_1:
    name: measured_frequency_1
    annotations:
      order:
        tag: order
        value: 64
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_1[Hz]
    description: frequency measurement, phase 1N
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_2:
    name: measured_angle_2
    annotations:
      order:
        tag: order
        value: 65
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_2[rad]
    description: bus angle measurement, phase 2N
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_2:
    name: measured_frequency_2
    annotations:
      order:
        tag: order
        value: 66
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_2[Hz]
    description: frequency measurement, phase 2N
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_angle_12:
    name: measured_angle_12
    annotations:
      order:
        tag: order
        value: 67
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_angle_12[rad]
    description: bus angle measurement, across the phases
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: rad
  measured_frequency_12:
    name: measured_frequency_12
    annotations:
      order:
        tag: order
        value: 68
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency_12[Hz]
    description: frequency measurement, across the phases
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    rank: 1000
    owner: triplex_load
    domain_of:
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  measured_frequency:
    name: measured_frequency
    annotations:
      order:
        tag: order
        value: 69
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: measured_frequency[Hz]
    description: frequency measurement - average of present phases
    from_schema: https://gridlabd.org/schema/glm/powerflow/triplex_node
    owner: triplex_load
    domain_of:
    - node
    - triplex_node
    range: float
    required: false
    unit:
      ucum_code: Hz
  phases:
    name: phases
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: phases
    comments:
    - 'Import: structural. Bus: a child''s conductors must be a subset of its root''s.
      Switch: Terminal phases, A B C with N dropped, blank when ABC. Series_reactor:
      Terminal.phases when fewer than three. Swing bus: EnergySource.phases, blank
      when ABC. Export: the A, B, C of the terminals on the bus, then N (S on a split-phase
      bus); a switch or reactor side 1''s A, B, C.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    related_mappings:
    - cim:Terminal.phases
    rank: 1000
    owner: triplex_load
    domain_of:
    - powerflow_object
    - inverter
    - rectifier
    - windturb_dg
    range: string
    required: false
  nominal_voltage:
    name: nominal_voltage
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 6
      native_name:
        tag: native_name
        value: nominal_voltage[V]
    comments:
    - 'Import: not copied; the topology walk gives the BaseVoltage, and a bus value
      over 10 percent off it is listed in bus.cimtbl. On a swing bus: EnergySource.nominalVoltage
      (V as written), line to line. Export: BaseVoltage LL / sqrt 3 (three phase),
      LL (single phase), LL / 2 (split phase leg); a substation: EnergySource.nominalVoltage
      / sqrt 3.'
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    close_mappings:
    - cim:BaseVoltage.nominalVoltage
    - cim:EnergySource.nominalVoltage
    rank: 1000
    owner: triplex_load
    domain_of:
    - powerflow_object
    - battery
    - waterheater
    range: float
    required: false
    unit:
      ucum_code: V
  inrush_integration_method:
    name: inrush_integration_method
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: inrush_integration_method
    description: Integration method for in-rush
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: triplex_load
    domain_of:
    - powerflow_object
    range: string
    required: false
  condition:
    name: condition
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: condition
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: triplex_load
    domain_of:
    - powerflow_object
    range: string
    required: false
  solution:
    name: solution
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: solution
    from_schema: https://gridlabd.org/schema/glm/powerflow/powerflow_object
    rank: 1000
    owner: triplex_load
    domain_of:
    - powerflow_object
    range: string
    required: false
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: name
    description: The object's name; unique across the model.
    comments:
    - 'Import: <CIM class>.name, copied as written; mRID = the class''s prefix + name
      (none on a bus). Export: Names, sanitized for GridLAB-D; a name two objects
      share raises.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    exact_mappings:
    - cim:IdentifiedObject.name
    rank: 1000
    identifier: true
    owner: triplex_load
    domain_of:
    - glm_object
    range: string
    required: true
  parent:
    name: parent
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: parent
    description: The parent object's name. A child node is solved as its parent's
      bus; a nested object block sets it to the enclosing object.
    comments:
    - 'Import: a bus whose parent is a bus is its root bus''s ConnectivityNode, named
      on the root''s row; no object of its own. On a link it is not mapped.'
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: triplex_load
    domain_of:
    - glm_object
    range: string
  groupid:
    name: groupid
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: groupid
    description: Free-text group label.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: triplex_load
    domain_of:
    - glm_object
    range: string
  latitude:
    name: latitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: latitude
    description: Latitude, as written (decimal degrees or GridLAB-D's 37N26:12 form).
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: triplex_load
    domain_of:
    - glm_object
    range: string
  longitude:
    name: longitude
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: longitude
    description: Longitude, as written.
    comments:
    - Not converted. Home is the EquipmentLocation shape.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: triplex_load
    domain_of:
    - glm_object
    range: string
  in_svc:
    name: in_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: in_svc
    description: Timestamp the object enters service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: triplex_load
    domain_of:
    - glm_object
    range: string
  out_svc:
    name: out_svc
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: out_svc
    description: Timestamp the object leaves service.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: triplex_load
    domain_of:
    - glm_object
    range: string
  rank:
    name: rank
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: rank
    description: Solver rank.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: triplex_load
    domain_of:
    - glm_object
    range: string
  flags:
    name: flags
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: string
      native_name:
        tag: native_name
        value: flags
    description: Core object flags.
    from_schema: https://gridlabd.org/schema/glm/types/common
    rank: 1000
    owner: triplex_load
    domain_of:
    - glm_object
    range: string