Skip to content

Import: DSS to CIM

from cimhub_opendss import DssReader, dss_to_cim

model = DssReader("cimhub_opendss/tests/decks/IEEE/IEEE13_CDPSM/IEEE13_CDPSM.dss").read_all()
network = dss_to_cim(model, name="IEEE13_CDPSM", artifact_dir="artifacts/IEEE13_CDPSM")

network is a cim18v17 cim-graph model. artifact_dir keeps the .cimtbl text it was built from.

What happens

  1. DssReader(path).read_all() follows Redirects and ~ continuation lines, evaluates RPN values, and returns a DssModel of typed records. Edit, dotted edits, Open/Close and batch edits are applied as the engine would.
  2. DssImporter(name).to_cimtbl(model) walks the deck's topology once (with cimtopology), then runs one mapper per DSS class. Each mapper turns records into a .cimtbl document. It does not build CIM objects.
  3. dss_to_cim writes the documents and cimtables binds them into a network. A last part, buscoords.cimtbl, is mapped from the bound network because it needs the equipment's terminals.

The .cimtbl text is the only input to CIM. If a value is wrong in the network, it is wrong in the text, and you can read it there.

Options

dss_to_cim(model, *, name, authority=..., length_unit=None, device_geometry="point", network=None, artifact_dir=None, time_points=None). DssImporter takes the same keywords except network and artifact_dir, which go to its to_cim method.

Argument Meaning
name Required. The master document's Model and file stem.
artifact_dir Keep the .cimtbl files here. Without it they go to a temporary directory that is removed after loading.
network An existing cim18v17 network to bind onto, to merge several decks. A bus the decks share by name must have the same base voltage in both, or binding raises.
authority The master's Authority. Defaults to https://github.com/PNNL-CIM-Tools/CIMHub.
length_unit The per-length unit ('km', 'kft', ...) for a LineCode that has no units of its own and whose lines set none, and for a line's own inline values when the line sets none. It overrides the importer's magnitude check (see lines).
device_geometry "point" (default) places a two-terminal device, such as a switch or transformer, as a point midway between its buses; "linestring" draws it from bus to bus. Any other value raises when the importer is made.
time_points A dict the importer fills with the points of the deck's yearly LoadShapes. See Load shapes and time points.

To get the documents without binding them, call DssImporter(name).to_cimtbl(model). It returns a DocumentSet with a master and a list of parts, and touches no files.

The artifacts

For the IEEE 13-node deck, artifact_dir holds one file per DSS table, plus the master:

IEEE13_CDPSM.cimtbl   bus.cimtbl        zip_fractions.cimtbl   linegeometry.cimtbl
linecode.cimtbl       xfmrcode.cimtbl   vsource.cimtbl         line.cimtbl
transformer.cimtbl    regcontrol.cimtbl load.cimtbl            capacitor.cimtbl
pvsystem.cimtbl       storage.cimtbl    buscoords.cimtbl

The master holds the Substation and Feeder (named for the deck's circuit), the BaseFrequency, one BaseVoltage per bus voltage and per voltagebases value, and one Import per part, in this order:

File From Notes
<name>.cimtbl the deck the master; its comment lists the DSS classes no mapper reads (not mapped: Relay 1)
bus.cimtbl the topology walk one ConnectivityNode per bus, with its BaseVoltage
zip_fractions.cimtbl always the shared load-response rows (zip_constant_pq, ...) that loads name
wiredata.cimtbl, cndata.cimtbl, tsdata.cimtbl WireData, CNData, TSData wire and cable catalogs
linespacing.cimtbl, linegeometry.cimtbl LineSpacing, LineGeometry, Set earthmodel geometry, as XYSpacing and WireConfiguration, and the deck's EarthResistivity. A deck without geometry that sets earthmodel (IEEE 13) gets a linegeometry.cimtbl with the EarthResistivity alone
linecode.cimtbl LineCode
xfmrcode.cimtbl XfmrCode
vsource.cimtbl Vsource
line.cimtbl Line, with its Fuse, Recloser and SwtControl
reactor.cimtbl Reactor
transformer.cimtbl, regcontrol.cimtbl Transformer, RegControl
loadshape.cimtbl LoadShape only shapes a Load names as yearly
load.cimtbl Load
capacitor.cimtbl, capcontrol.cimtbl Capacitor, CapControl
pvsystem.cimtbl, storage.cimtbl, generator.cimtbl PVSystem, Storage, Generator
buscoords.cimtbl BusCoords, LatLongCoords files always last: it reads the bound Terminals

Catalogs come before the equipment that uses them. A class with no records writes no part and no Import. Values keep the deck's units, and the unit sits in the column header, for example p (kW). A comment above a row says what the importer defaulted (# defaulted: NumCust=1, enabled=true). The per-field rules are in the import mapping; how a table is written is in the .cimtbl contract.

Bus coordinates

BusCoords and LatLongCoords commands name CSV files of bus, x, y (or bus, lat, long) rows, separated by commas or white space. The reader reads them; the importer gives each piece of equipment a CIM Location. A line is a LINESTRING through its buses. Any other equipment is a POINT at its bus, or at the midpoint of its buses. Equipment gets a Location only if every one of its buses has coordinates, and the file's comment counts the rest (not located: <n> of <m> equipment). A row naming a bus the circuit does not have is ignored, as the engine does, and listed in the file's comment (no such bus: <n> (<first names>)). A row that is not bus, x, y raises with its file and line. A deck that uses both directives raises.

Load shapes and time points

A LoadShape that a Load names as yearly becomes a ConformLoadGroup and a ConformLoadSchedule. One that a PVSystem, Storage or Generator names becomes that device's own EnergyConnectionSchedule. The schedule is in the model; its points are not, because a year of points is too many CIM objects. They go to a dict of Arrow tables that you pass in:

from cimhub_opendss import DssReader, dss_to_cim

time_points = {}
model = DssReader("cimhub_opendss/tests/atoms/loadshape/loadshapes.dss").read_all()
network = dss_to_cim(model, name="loadshapes", time_points=time_points)
print(list(time_points), time_points["RegularTimePoint"].num_rows)

This needs the time-points extra. It prints ['RegularTimePoint'] 11. The tables are written beside a CIM XML file by cimhub_core.time_points.write_time_points; see Time series and schedules in core. Without time_points=, the importer logs one warning that names the dropped shapes and goes on. The master's comment counts a shape nothing names as yearly (not mapped: Loadshape 1). To write the points back, see Export.

What raises

The importer fails rather than guessing. Each message names the DSS object.

Cause What you get
A file the deck redirects to is missing, or a line does not parse DssParseError with the file and line: Redirect target not found: <path> in <deck> at line 2
A property the schema does not have DssParseError: unknown property 'bogusprop' on Line: <the command> in <deck> at line 3
A DSS class the schema does not have DssParseError: Wibble.x: unknown DSS class 'Wibble' in <deck> at line 3
A deck with no New Circuit ValueError: the deck has no New Circuit
A second New Circuit DssParseError: a second New Circuit (the first is 'a'); a deck is one circuit
A property the mapper classifies as raising when set ValueError: Line l1: Seasons, Ratings not mapped yet (no deck in the sweep sets them)
Equipment on a bus the topology walk does not reach ValueError: Load ld2: bus zz has no voltage (the topology walk did not reach it). A Vsource and a Transformer say Vsource <name>: no bus voltage for <bus>
A Line whose phases differ from its LineCode's nphases ValueError: Line <name>: phases=1 with LineCode <code> (nphases=3); the engine's rule is not pinned yet (DSS-10). The EPRI K1 and M1 feeders stop here
A line code with no units, whose lines give none and whose median r fits no unit ValueError: LineCodes with no units: median r <x> per unit fits no length unit ...; pass length_unit=
A device_geometry other than "point" or "linestring" ValueError when the importer is made

DssParseError has file_path and line_number attributes. The ValueErrors of the mappers come from the classification of each DSS property: copied, mapped, structural, derived, untranscribed, or raising when set. A property that raises says in the import mapping which deck would justify mapping it. The ones users meet most:

Class Properties Why
Line, WireData, CNData, TSData Seasons, Ratings An indexed rating array that names no calendar season.
WireData, CNData, TSData GMRac unset; both or neither of radius and diam set; a unit (Runits, GMRunits, radunits) unset; neither Rac nor Rdc set The engine's default, or the last property set, is not recorded by the reader.
WireData, CNData, TSData Capradius No mapping yet.
Transformer, XfmrCode RdcOhms on some windings only, or on a 3-phase inline transformer or a regulator; Seasons without Ratings, or a Ratings count other than Seasons The engine's default for an unset winding is not recorded; a balanced end or an AutoTransformerEnd has no winding rDC; the engine keeps only Seasons ratings and pads the rest with zeros.
CNData SemiconLayer No mapping yet.
LoadShape UseActual=Yes, hour, csvfile, sngfile, dblfile, PQCSVFile, Pmult, Pbase, Qbase; an npts other than the number of values No deck uses them, or the result depends on command order.
Load a yearly that names no shape in the deck The reference does not resolve: Load ld: yearly=nope names no LoadShape of the deck.

What is skipped, loudly

A DSS class no mapper reads (monitors, meters, curves, and so on) is not an error. The master's comment lists it as not mapped: <Class> <count>, so nothing disappears silently. What converts has the list. What the class would have configured is absent from the CIM network.

Next

Export goes the other way. Round trip checks that a deck survives both.