The importer¶
The importer takes a DssModel and builds a cim18v17 network in two steps that never share objects: the mappers
turn DSS records into .cimtbl documents (text), and cimtables binds that text. The code is
importer/dss_to_cimtbl.py
(the orchestrator), importer/topology.py (the bus walk) and one mapper per DSS class in
importer/cimtbl/.
The design record for each class is CIMTBL_MAPPING.md. The helpers every mapper uses
(cell, mrid, lookup, Field, check_fields) are core's, and are described on the core site's
.cimtbl import contract page.
The entry points¶
import tempfile
from pathlib import Path
from cimtables.document import format_document
from cimhub_opendss import DssImporter, DssReader, dss_to_cim
model = DssReader("cimhub_opendss/tests/decks/IEEE/IEEE13_CDPSM/IEEE13_CDPSM.dss").read_all()
documents = DssImporter("IEEE13_CDPSM").to_cimtbl(model) # pure: a DocumentSet, nothing written
print([part.name for part in documents.parts])
print(format_document(documents.master)[:200])
artifact_dir = Path(tempfile.mkdtemp(prefix="ieee13_artifact_")) # a new, empty directory
network = dss_to_cim(model, name="IEEE13_CDPSM", artifact_dir=artifact_dir) # writes, then binds
print(sorted(path.name for path in artifact_dir.iterdir())[:4])
| Call | Does |
|---|---|
DssImporter(name, *, authority, length_unit, device_geometry, time_points) |
name is the master's Model and the file stem. authority defaults to AUTHORITY (https://github.com/PNNL-CIM-Tools/CIMHub). length_unit sets the per-length unit of line codes with no units on code or line, instead of the magnitude gate. device_geometry is "point" (default) or "linestring", how a two-terminal device is drawn in buscoords.cimtbl; anything else raises. time_points is the caller's dict for the yearly shapes' points. |
.to_cimtbl(model) |
Returns the DocumentSet: master plus parts. No file is written. |
.to_cim(model, *, network=None, artifact_dir=None) |
The core to_cim: write the documents (to artifact_dir, which must hold no .cimtbl file the set does not write, else a temporary directory), load them with cimtables, then add the bound_parts. With network, binds onto it. Then it adds the yearly shapes' time points to time_points. |
.bound_parts(model, network) |
[buscoords.map_buscoords(model, network, device_geometry)]: the one part that reads the bound Terminals. |
dss_to_cim(model, *, name, ...) |
Builds a DssImporter and calls to_cim. |
The yearly shapes' points do not go in the artifact; they go to the caller's time_points (the Parquet sidecar,
which needs the time-points extra). Without time_points they are dropped with one warning that names the shapes.
to_cimtbl¶
to_cimtbl does five things, in this order:
site(model, length_unit)runs the topology walk once and returns aSite(aNamedTuple): the circuit name, the walk'sbuses, thesubstationandfeedermRIDs (sub_<circuit>,fdr_<circuit>),base_frequencyandlength_unit. A deck with noNew Circuitraisesthe deck has no New Circuit.map_buses(site)makesbus.cimtbl: oneConnectivityNodeper bus the walk reached, with itsBaseVoltage, highest voltage first, then by name.cimhub_core.load_response.zip_fractions()makes the sharedzip_fractions.cimtbl(the three ZIP characteristics).- Each
(native class, mapper)ofMAPPING_ORDERis called asmapper(model, site)and returns one document. - Documents with no statements are dropped, and
map_mastermakes the master, whichImports each remaining part in order.
MAPPING_ORDER is the Import order, and a class comes after what it names: the wire catalogs, LineSpacing,
LineGeometry, LineCode, XfmrCode, Vsource, Line, Reactor, Transformer, RegControl, LoadShape, Load,
Capacitor, CapControl, PVSystem, Storage, Generator. A lambda per entry passes each mapper only what it
needs from the Site (the buses, the feeder mRID, the base frequency, the length unit). A test checks that no native
class is listed twice. buscoords.cimtbl is not in the list; bound_parts adds it last.
The master¶
map_master writes the model's containers and its bases, then one Import per part:
| Statement | Content |
|---|---|
Substation, Feeder |
Named after the circuit; the Feeder's NormalEnergizingSubstation is the Substation. |
BaseFrequency |
Set defaultbasefreq, else the DSS default, with a defaulted: comment. |
BaseVoltage |
One per distinct bus voltage from the walk and one per voltagebases value, highest first. A base on no bus is kept: the engine's CalcVoltageBases snaps bus bases to it, so the export writes it back. The comment reconciles the two lists (on no bus, not in voltagebases). |
OperationalLimitType |
The two limit types, olt_normal and olt_emergency, which every CurrentLimit names, then olt_season1 .. olt_season<N> for the most seasons any Transformer or XfmrCode rates (limit_types(seasons)), which their ApparentPowerLimits name. |
| comment | not mapped: Relay 1, ... lists each DSS class no mapper reads, by count, so nothing disappears silently. A LoadShape no Load, PVSystem, Storage or Generator names as yearly is counted too. |
READ_BY_OTHERS lists the classes that another mapper reads in full (Fuse, Recloser, SwtControl, from
line.CONTROLS); they count as mapped.
The topology walk¶
importer/topology.py builds a cimtopology.core.Network from the deck, and walk(network) gives each bus its nominal
voltage and system (BusSystem). A spoke never writes its own graph walk (invariant I9).
Network part |
From the DSS model |
|---|---|
sources |
Every Vsource, New Circuit included, with its DSS defaults (vsource.with_defaults). basekv is line to line on a 3-phase source and the source voltage on a 1-phase one; other phase counts raise. |
branches |
Every Line (a switch keeps its voltage, open or not), and every Reactor or Capacitor with a bus2 on another bus. |
transformers |
Every Transformer, with phases, windings, kVs and conns from the instance, else from its XfmrCode. A polyphase winding's kV is line to line. A single-phase coil's connection comes from its nodes (1 to 3 are phase conductors); windings 2 and 3 on one bus form a split-phase secondary (transformer.is_split_phase). |
from cimtopology.core import walk
from cimhub_opendss.importer.topology import dss_network
buses = walk(dss_network(model))
print(len(buses), buses["611"]) # 22 BusSystem(kv=4.16, system=<System.THREE_PHASE: '3-phase'>)
Bus names are lowercased, as the mappers use them. The BaseVoltage of every piece of equipment comes from this walk,
not from a kV on the device; a Load whose kV is more than 1 % off its bus's raises.
The mapper layout¶
Each mapper module in importer/cimtbl/ has these parts (wire.py and geometry.py map several classes and have no single NATIVE_CLASS or PREFIX; loadshape.py and buscoords.py have no PREFIX; injection.py and inverter.py are shared helpers, not mappers):
| Part | Role |
|---|---|
NATIVE_CLASS |
The schema class it maps (schema.Linecode). |
PREFIX |
The mRID prefix (lc_); an mRID is mrid(PREFIX, name, lowercase=True), since DSS names are case-insensitive. |
FIELDS |
{slot: Field}: every slot of the native class, classified. |
map_<class>(native, ...) |
A pure function: records in, one Document out. An empty class returns a Document with no statements. |
_PROVENANCE |
The document's header comment: what it maps, the record count and the spec anchor. |
Field(kind, targets=(), note="") is core's classification. kind is one of copied, mapped, structural,
derived, untranscribed. A copied field names its targets, (cim_class, column, unit), and the unit can hold a
placeholder such as ohm/{length}; copied_columns(FIELDS, cim_class, length=unit) fills it from the record's own
unit and returns the (slot, Column) pairs. untranscribed_values(FIELDS, record) gives the # untranscribed: ...
comment for the untranscribed slots a record has set, so nothing is dropped silently. fill_defaults(FIELDS, record,
defaults) returns a copy with each unset slot the mapper reads filled from dss_defaults(NATIVE_CLASS), and a
defaulted: comment.
The rules a mapper keeps:
- Values are copied verbatim with the deck's unit in the column header:
Column("r", "ohm/km"), cell text fromcell(value). A quantity CIM has no attribute for goes through a named function and is markedderivedinFIELDSand in a table comment. A formula keeps its units with its values, ascimhub_core.derived.capacitancedoes, and the header names the result's unit: kVAr / kV² isbPerSection (mS), kV² / kVA isr (kohm). A plain-float target (RegulatingControl.targetValue) in kvar or kV carriestargetValueUnitMultiplier=k. No mapper multiplies by 1000 or builds acim.Xvalue. - An unset property the mapper needs is a
defaulted:comment or a raise; never a guess. - A property the mapping does not cover raises when the deck sets it (
not mapped yet (no deck in the sweep sets them)). When a deck needs it, the spec gains the mapping first. - Ambiguity raises. A property that DSS resolves by assignment order, which the record does not keep, is read from
model.assignmentsor raises.
One mapper end to end: LineCode¶
linecode.py
maps LineCode to a template PerLengthImpedance and a WireConfiguration for the lines to reference (I6). Take this
deck line:
New Linecode.3-1/0C_2/0CN_T nphases=3 r1=0.3489 x1=0.426198 r0=0.588811 x0=1.29612 c1=10.4308823411236 c0=4.48501282215346 units=km baseFreq=60 normamps=310 emergamps=310 faultrate=0.1 pctperm=20 repair=3
from cimtables.document import format_document
from cimhub_opendss.importer.cimtbl.linecode import map_linecode
atom = DssReader("cimhub_opendss/tests/atoms/linecode/seq_3_1_0c.dss").read_all()
print(format_document(map_linecode(atom, base_frequency=60.0)))
The reader gives a Linecode record. map_linecode(native, *, base_frequency, length_unit=None) then:
- Finds each code's length unit (
templates). A code withunitstakes it, looked up inLENGTH_UNIT(an unmapped unit raises with the known ones). A code with none takes the units of the lines that use it, one template per unit (lc_<name>_<unit>), and a code used with and without units raises. A code no line gives units for takeslength_unit=, else the magnitude gate (gated_unit: the median positive r throughUNITS_GATE), and says which in a comment. - Chooses the form (
is_sequence): a 3-phaser1/x1/r0/x0/C1/C0/B1/B0code is aPerLengthSequenceImpedance; a matrix is aPerLengthPhaseImpedancewith onePhaseImpedanceDatarow per lower-triangle element, and so is a 1- or 2-phase sequence code, built as a phase matrix the way the engine builds the line (phase_matrix). Both forms or neither raises. - Fills what the DSS engine would: a missing
cmatrixbecomes the balanced default matrix, and a code with a nonzero C and nobaseFreqtakes the deck's base frequency. Both aredefaulted:comments. - Writes the columns with the code's unit (
r (ohm/km));C1becomesbch (nS/km)throughb_from_c, which is why the table's header comment saysderived. - Writes
normamps,faultrateand the rest as an# untranscribed:comment, and aWireConfigurationlc_<name>_wcthat points at the template.
The result is the golden tests/atoms/linecode/seq_3_1_0c.cimtbl:
Table PerLengthSequenceImpedance: mRID, name, r (ohm/km), x (ohm/km), r0 (ohm/km), x0 (ohm/km), calculatedFrequency (Hz), bch (nS/km), b0ch (nS/km), isTemplate
# untranscribed: normamps=310.0, emergamps=310.0, faultrate=0.1, pctperm=20.0, repair=3
lc_3-1/0c_2/0cn_t, 3-1/0C_2/0CN_T, 0.3489, 0.426198, 0.588811, 1.29612, 60, 3932.350000000008, 1690.8100000000002, true
Table WireConfiguration: mRID, name, PerLengthImpedance
lc_3-1/0c_2/0cn_t_wc, 3-1/0C_2/0CN_T, lc_3-1/0c_2/0cn_t
The mRID keeps the deck's - and / (lowercased); a name holding ,, (, ), # or " is quoted by the formatter, never sanitized (I8). The classification is checked by a test, and so is each fail-fast rule:
from cimhub_core.cimtbl import check_fields
from cimhub_opendss.importer.cimtbl.linecode import FIELDS, NATIVE_CLASS
check_fields(FIELDS, NATIVE_CLASS) # raises AssertionError listing missing and stale slots
Adding a mapper for a new DSS class¶
- Spec first. Add a section to CIMTBL_MAPPING.md: every property of the class classified, the CIM class and shape it becomes, the mRID prefix, the fail-fast rules and the expected differences. A mapper without an approved section is not merged.
- The mapper.
cimhub_core.scaffold.scaffold_mapper("opendss", schema.Foo, prefix="foo_", records=...)writes the stub and the completeness test:NATIVE_CLASS,PREFIX,FIELDSwith one entry per slot, andmap_foo. FillFIELDSfrom the spec, then writemap_foo(native, ...)returning aDocument. Pick the table shape from core's canonical shapes. - The order. Add
(foo.NATIVE_CLASS, lambda native, site: foo.map_foo(native, site.buses, site.feeder))toMAPPING_ORDER, after every class its rows reference. If another mapper reads the class, add it toREAD_BY_OTHERS. If the class needs terminals bound first, make it abound_partspart instead. - The atom pair. Add
tests/atoms/<table>/<case>.dss(a few lines from a public deck, with its origin in a comment) and the reviewed<case>.cimtblgolden. - The tests.
tests/test_cimtbl_<table>.py:check_fields, the golden (assert_matches_golden), the binding under cim18v17 with key values checked in SI (.to(unit)), and each fail-fast rule withpytest.raises(..., match=...). Add the engine as the oracle where OpenDSS computes the same quantity. Testing lists the helpers. - The golden directory. If the IEEE13_CDPSM deck has the class, regenerate with
CIMHUB_UPDATE_GOLDENS=1, and review the diff intests/goldens/IEEE13_CDPSM/. - The sweep. If a deck in
test_cimtbl_sweep.py'sSWEEP_STOPSstopped on this class, update its row; the test fails when a listed stop now binds. - Run
scripts/test-all.sh opendssandscripts/leak-gate.sh.