Class: Capcontrol¶
A Capcontrol object in OpenDSS representing a capacitor bank control that monitors a line or transformer and switches the capacitor ON or OFF.
URI: dss:Capcontrol
classDiagram
class Capcontrol
click Capcontrol href "../Capcontrol/"
Capcontrol : basefreq
Capcontrol : capacitor
Capcontrol : ControlSignal
Capcontrol : CTPhase
Capcontrol : CTratio
Capcontrol : DeadTime
Capcontrol : Delay
Capcontrol : DelayOFF
Capcontrol : element
Capcontrol : enabled
Capcontrol : EventLog
Capcontrol : like
Capcontrol : name
Capcontrol : OFFsetting
Capcontrol : ONsetting
Capcontrol : pctMinkvar
Capcontrol : PTPhase
Capcontrol : PTratio
Capcontrol : Reset
Capcontrol : terminal
Capcontrol : type
Capcontrol : UserData
Capcontrol : UserModel
Capcontrol : VBus
Capcontrol : Vmax
Capcontrol : Vmin
Capcontrol : VoltOverride
Class Properties¶
| Property | Value |
|---|---|
| Class URI | dss:Capcontrol |
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| name | 1 String |
Object name | direct |
| element | 0..1 String |
Full object name of the circuit element (typically a line or transformer) to ... | direct |
| terminal | 0..1 Integer |
Number of the terminal of the circuit element to which the CapControl is conn... | direct |
| capacitor | 0..1 String |
Name of Capacitor element which the CapControl controls | direct |
| type | 0..1 String |
{Current | voltage |
| PTratio | 0..1 Float |
Ratio of the PT that converts the monitored voltage to the control voltage | direct |
| CTratio | 0..1 Float |
Ratio of the CT from line amps to control ampere setting for current and kvar... | direct |
| ONsetting | 0..1 Float |
Value at which the control arms to switch the capacitor ON (or ratchet up a s... | direct |
| OFFsetting | 0..1 Float |
Value at which the control arms to switch the capacitor OFF | direct |
| Delay | 0..1 Float |
Time delay, in seconds, from when the control is armed before it sends the sw... | direct |
| VoltOverride | 0..1 Boolean |
{Yes | No} Default is No |
| Vmax | 0..1 Float |
Maximum voltage, in volts, above which control is forced ON regardless of con... | direct |
| Vmin | 0..1 Float |
Minimum voltage, in volts, below which control is forced OFF regardless of co... | direct |
| DelayOFF | 0..1 Float |
Time delay, in seconds, for control to turn OFF when present state is ON | direct |
| DeadTime | 0..1 Float |
Dead time after capacitor is turned OFF before it can be turned back ON | direct |
| CTPhase | 0..1 String |
Number of the phase being monitored for CURRENT control or one of {AVG | MAX ... |
| PTPhase | 0..1 String |
Number of the phase being monitored for VOLTAGE control or one of {AVG | MAX ... |
| VBus | 0..1 String |
Name of bus to use for voltage override function | direct |
| EventLog | 0..1 Boolean |
{Yes/True* | No/False} Default is YES for CapControl |
| UserModel | 0..1 String |
Name of DLL containing user-written CapControl model | direct |
| UserData | 0..1 String |
String that gets passed to the user-written CapControl model | direct |
| pctMinkvar | 0..1 Float |
For PF control option, min percent of total bank kvar at which control will c... | direct |
| Reset | 0..1 Boolean |
{Yes | No} If Yes, forces Reset of this CapControl |
| ControlSignal | 0..1 String |
Name of the load shape used for controlling the connection/disconnection of t... | direct |
| basefreq | 0..1 Float |
Base Frequency for ratings | direct |
| enabled | 0..1 Boolean |
{Yes | No or True |
| like | 0..1 String |
Make like another object, e | direct |
Comments¶
- Import: one RegulatingControl cc_ + name on the monitored Terminal (capcontrol.cimtbl); its capacitor gets RegulatingControl, aVRDelay and controlEnabled by an Update. Export: one CapControl per RegulatingControl that regulates one LinearShuntCompensator.
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridappsd.github.io/dss-graph/opendss
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | dss:Capcontrol |
| native | dss:Capcontrol |
| exact | cim:RegulatingControl |
LinkML Source¶
Direct¶
name: Capcontrol
description: A Capcontrol object in OpenDSS representing a capacitor bank control
that monitors a line or transformer and switches the capacitor ON or OFF.
comments:
- 'Import: one RegulatingControl cc_ + name on the monitored Terminal (capcontrol.cimtbl);
its capacitor gets RegulatingControl, aVRDelay and controlEnabled by an Update.
Export: one CapControl per RegulatingControl that regulates one LinearShuntCompensator.'
from_schema: https://gridappsd.github.io/dss-graph/opendss
exact_mappings:
- cim:RegulatingControl
attributes:
name:
name: name
description: Object name. Must be unique per object type.
comments:
- 'Import: RegulatingControl.name, mRID = cc_ + name, lowercased. Export: Names,
the CapControl namespace.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:IdentifiedObject.name
identifier: true
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Buscoords
- Cndata
- Dynamicexp
- Growthshape
- Linecode
- Linegeometry
- Linespacing
- Loadshape
- Priceshape
- Spectrum
- TccCurve
- Tsdata
- Tshape
- Wiredata
- Xfmrcode
- Xycurve
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Options
- Vsource
range: string
required: true
element:
name: element
annotations:
order:
tag: order
value: 1
description: Full object name of the circuit element (typically a line or transformer)
to which the capacitor control's PT and/or CT are connected.
comments:
- 'Import: the Terminal of the Line (ln_ or sw_) or Capacitor (cap_) it names;
another element class raises. Export: Line.<name> or Capacitor.<name> of the
monitored Terminal''s equipment.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.Terminal
rank: 1000
domain_of:
- Capcontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
range: string
required: false
terminal:
name: terminal
annotations:
order:
tag: order
value: 2
dss_default:
tag: dss_default
value: int(1)
description: Number of the terminal of the circuit element to which the CapControl
is connected. Default is 1.
comments:
- 'Import: the element''s terminal, default 1. Export: the monitored Terminal''s
sequenceNumber.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.Terminal
rank: 1000
domain_of:
- Capcontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
range: integer
required: false
capacitor:
name: capacitor
annotations:
order:
tag: order
value: 3
description: Name of Capacitor element which the CapControl controls.
comments:
- 'Import: the Update row on cap_<capacitor>; a capacitor no New defines raises.
Export: the one LinearShuntCompensator the control regulates.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingCondEq.RegulatingControl
rank: 1000
domain_of:
- Capcontrol
range: string
required: false
type:
name: type
annotations:
order:
tag: order
value: 4
dss_default:
tag: dss_default
value: string(current)
description: '{Current | voltage | kvar | PF | time | Follow} Control type. Default
is current.'
comments:
- 'Import: voltage -> voltage, current -> currentFlow, kvar -> reactivePower,
time -> timeScheduled; PF and Follow raise; default current. Export: the reverse;
other modes raise.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.mode
rank: 1000
domain_of:
- Capcontrol
- Relay
range: string
required: false
PTratio:
name: PTratio
annotations:
order:
tag: order
value: 5
dss_default:
tag: dss_default
value: float(60.0)
description: Ratio of the PT that converts the monitored voltage to the control
voltage. Default is 60.
comments:
- 'Import: ptRatio; default 60. Export: ptRatio; unset raises for a voltage control.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:RegulatingControl.ptRatio
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
minimum_value: 0.0
CTratio:
name: CTratio
annotations:
order:
tag: order
value: 6
dss_default:
tag: dss_default
value: float(60.0)
description: Ratio of the CT from line amps to control ampere setting for current
and kvar control types. Default is 60.
comments:
- 'Import: ctRatio; default 60. Export: ctRatio; unset raises for a current control.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:RegulatingControl.ctRatio
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
minimum_value: 0.0
ONsetting:
name: ONsetting
annotations:
order:
tag: order
value: 7
dss_default:
tag: dss_default
value: float(300.0)
dss_name:
tag: dss_name
value: 'on'
description: Value at which the control arms to switch the capacitor ON (or ratchet
up a step). Default is 300 amps.
comments:
- 'Import: derived; targetValue = (ON + OFF) / 2, voltage x PTratio (V), current
x CTratio (A), kvar in kvar (targetValueUnitMultiplier k), time in hours; ON
on the wrong side of OFF raises; default 300. Export: targetValue -+ targetDeadband
/ 2, divided by the ratio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.targetValue
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
OFFsetting:
name: OFFsetting
annotations:
order:
tag: order
value: 8
dss_default:
tag: dss_default
value: float(200.0)
dss_name:
tag: dss_name
value: 'off'
description: Value at which the control arms to switch the capacitor OFF. Default
is 200 amps.
comments:
- 'Import: derived; targetDeadband = abs(OFF - ON), scaled as ONsetting; default
200. Export: targetValue +- targetDeadband / 2; an unset deadband raises.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.targetDeadband
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
Delay:
name: Delay
annotations:
order:
tag: order
value: 9
dss_default:
tag: dss_default
value: float(15.0)
description: Time delay, in seconds, from when the control is armed before it
sends the switching command to turn ON. Default is 15 s.
comments:
- 'Import: aVRDelay (s) on the compensator''s Update row; default 15. Export:
aVRDelay (s); unset -> not written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:ShuntCompensator.aVRDelay
rank: 1000
domain_of:
- Capcontrol
- Fuse
- Recloser
- Relay
- Swtcontrol
range: float
required: false
VoltOverride:
name: VoltOverride
annotations:
order:
tag: order
value: 10
description: '{Yes | No} Default is No. If Yes, enables the VoltOverride feature
using Vmax and Vmin limits.'
comments:
- 'Import: untranscribed (a voltage override band of a kvar or current control;
maxAllowedTargetValue limits the target, not the voltage). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: boolean
required: false
Vmax:
name: Vmax
annotations:
order:
tag: order
value: 11
description: Maximum voltage, in volts, above which control is forced ON regardless
of control type setting.
comments:
- 'Import: untranscribed (the VoltOverride band, volts on the PT secondary). Export:
unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
Vmin:
name: Vmin
annotations:
order:
tag: order
value: 12
description: Minimum voltage, in volts, below which control is forced OFF regardless
of control type setting.
comments:
- 'Import: untranscribed (the VoltOverride band, volts on the PT secondary). Export:
unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
DelayOFF:
name: DelayOFF
annotations:
order:
tag: order
value: 13
dss_default:
tag: dss_default
value: float(15.0)
description: Time delay, in seconds, for control to turn OFF when present state
is ON. Default is 15 s.
comments:
- 'Import: untranscribed (CIM has one aVRDelay (Delay); DSS solution control).
Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
DeadTime:
name: DeadTime
annotations:
order:
tag: order
value: 14
description: Dead time after capacitor is turned OFF before it can be turned back
ON. Default is 300 s.
comments:
- 'Import: untranscribed (DSS solution control; no home in the network profile
parts). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
CTPhase:
name: CTPhase
annotations:
order:
tag: order
value: 15
description: Number of the phase being monitored for CURRENT control or one of
{AVG | MAX | MIN} for all phases. Default is 1.
comments:
- 'Import: raises when set (a CT phase); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: string
required: false
PTPhase:
name: PTPhase
annotations:
order:
tag: order
value: 16
dss_default:
tag: dss_default
value: int(1)
description: Number of the phase being monitored for VOLTAGE control or one of
{AVG | MAX | MIN} for all phases. Default is 1.
comments:
- 'Import: monitoredPhase = the phase of the monitored terminal''s conductor PTPhase
(default 1); AVG, MAX and MIN raise. Export: the 1-based place of monitoredPhase
among the monitored equipment''s conductors.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.monitoredPhase
rank: 1000
domain_of:
- Capcontrol
range: string
required: false
VBus:
name: VBus
annotations:
order:
tag: order
value: 17
description: Name of bus to use for voltage override function. Defaults to monitored
element bus.
comments:
- 'Import: raises when set (remote voltage sensing); no deck in the sweep sets
it, so a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: string
required: false
EventLog:
name: EventLog
annotations:
order:
tag: order
value: 18
description: '{Yes/True* | No/False} Default is YES for CapControl. If Yes, writes
switching events to a log.'
comments:
- 'Import: untranscribed (DSS report flag). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
- Expcontrol
- Invcontrol
- Regcontrol
- Relay
- Storagecontroller
range: boolean
required: false
UserModel:
name: UserModel
annotations:
order:
tag: order
value: 19
description: Name of DLL containing user-written CapControl model.
comments:
- 'Import: raises when set (a user model); no deck in the sweep sets it, so a
mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
domain_of:
- Generator
- Pvsystem
- Storage
- Windgen
- Capcontrol
range: string
required: false
UserData:
name: UserData
annotations:
order:
tag: order
value: 20
description: String that gets passed to the user-written CapControl model.
comments:
- 'Import: raises when set (user data); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
domain_of:
- Generator
- Pvsystem
- Storage
- Windgen
- Capcontrol
range: string
required: false
pctMinkvar:
name: pctMinkvar
annotations:
order:
tag: order
value: 21
description: For PF control option, min percent of total bank kvar at which control
will close capacitor switch. Default is 50.
comments:
- 'Import: untranscribed (used only by PF control, which raises). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: float
required: false
Reset:
name: Reset
annotations:
order:
tag: order
value: 22
description: '{Yes | No} If Yes, forces Reset of this CapControl.'
comments:
- 'Import: untranscribed (a command, not a setting). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
- Recloser
- Regcontrol
- Relay
- Swtcontrol
range: boolean
required: false
ControlSignal:
name: ControlSignal
annotations:
order:
tag: order
value: 23
description: Name of the load shape used for controlling the connection/disconnection
of the capacitor to the grid.
todos:
- Loadshape converter not yet implemented. ControlSignal LoadShape reference should
map to a CIM SeasonDayTypeSchedule.
comments:
- 'Import: raises when set (a control signal); no deck in the sweep sets it, so
a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
domain_of:
- Capcontrol
range: string
required: false
basefreq:
name: basefreq
annotations:
order:
tag: order
value: 24
description: Base Frequency for ratings.
comments:
- 'Import: untranscribed (no home on a control). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: float
required: false
enabled:
name: enabled
annotations:
order:
tag: order
value: 25
dss_default:
tag: dss_default
value: 'true'
description: '{Yes|No or True|False} Indicates whether this element is enabled.'
comments:
- 'Import: the control''s enabled and the compensator''s controlEnabled; default
true. Export: the control''s enabled; the compensator''s must agree.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:RegulatingControl.enabled
- cim:RegulatingCondEq.controlEnabled
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: boolean
required: false
like:
name: like
annotations:
order:
tag: order
value: 26
description: 'Make like another object, e.g.: New Capcontrol.CC2 like=CC1 ...'
comments:
- 'Import: untranscribed; the reader resolves like= before mapping. Export: never
written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Cndata
- Dynamicexp
- Growthshape
- Linecode
- Linegeometry
- Linespacing
- Loadshape
- Priceshape
- Spectrum
- TccCurve
- Tsdata
- Tshape
- Wiredata
- Xfmrcode
- Xycurve
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: string
required: false
class_uri: dss:Capcontrol
Induced¶
name: Capcontrol
description: A Capcontrol object in OpenDSS representing a capacitor bank control
that monitors a line or transformer and switches the capacitor ON or OFF.
comments:
- 'Import: one RegulatingControl cc_ + name on the monitored Terminal (capcontrol.cimtbl);
its capacitor gets RegulatingControl, aVRDelay and controlEnabled by an Update.
Export: one CapControl per RegulatingControl that regulates one LinearShuntCompensator.'
from_schema: https://gridappsd.github.io/dss-graph/opendss
exact_mappings:
- cim:RegulatingControl
attributes:
name:
name: name
description: Object name. Must be unique per object type.
comments:
- 'Import: RegulatingControl.name, mRID = cc_ + name, lowercased. Export: Names,
the CapControl namespace.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:IdentifiedObject.name
identifier: true
owner: Capcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Buscoords
- Cndata
- Dynamicexp
- Growthshape
- Linecode
- Linegeometry
- Linespacing
- Loadshape
- Priceshape
- Spectrum
- TccCurve
- Tsdata
- Tshape
- Wiredata
- Xfmrcode
- Xycurve
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Options
- Vsource
range: string
required: true
element:
name: element
annotations:
order:
tag: order
value: 1
description: Full object name of the circuit element (typically a line or transformer)
to which the capacitor control's PT and/or CT are connected.
comments:
- 'Import: the Terminal of the Line (ln_ or sw_) or Capacitor (cap_) it names;
another element class raises. Export: Line.<name> or Capacitor.<name> of the
monitored Terminal''s equipment.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.Terminal
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
range: string
required: false
terminal:
name: terminal
annotations:
order:
tag: order
value: 2
dss_default:
tag: dss_default
value: int(1)
description: Number of the terminal of the circuit element to which the CapControl
is connected. Default is 1.
comments:
- 'Import: the element''s terminal, default 1. Export: the monitored Terminal''s
sequenceNumber.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.Terminal
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
range: integer
required: false
capacitor:
name: capacitor
annotations:
order:
tag: order
value: 3
description: Name of Capacitor element which the CapControl controls.
comments:
- 'Import: the Update row on cap_<capacitor>; a capacitor no New defines raises.
Export: the one LinearShuntCompensator the control regulates.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingCondEq.RegulatingControl
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: string
required: false
type:
name: type
annotations:
order:
tag: order
value: 4
dss_default:
tag: dss_default
value: string(current)
description: '{Current | voltage | kvar | PF | time | Follow} Control type. Default
is current.'
comments:
- 'Import: voltage -> voltage, current -> currentFlow, kvar -> reactivePower,
time -> timeScheduled; PF and Follow raise; default current. Export: the reverse;
other modes raise.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.mode
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
- Relay
range: string
required: false
PTratio:
name: PTratio
annotations:
order:
tag: order
value: 5
dss_default:
tag: dss_default
value: float(60.0)
description: Ratio of the PT that converts the monitored voltage to the control
voltage. Default is 60.
comments:
- 'Import: ptRatio; default 60. Export: ptRatio; unset raises for a voltage control.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:RegulatingControl.ptRatio
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
minimum_value: 0.0
CTratio:
name: CTratio
annotations:
order:
tag: order
value: 6
dss_default:
tag: dss_default
value: float(60.0)
description: Ratio of the CT from line amps to control ampere setting for current
and kvar control types. Default is 60.
comments:
- 'Import: ctRatio; default 60. Export: ctRatio; unset raises for a current control.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:RegulatingControl.ctRatio
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
minimum_value: 0.0
ONsetting:
name: ONsetting
annotations:
order:
tag: order
value: 7
dss_default:
tag: dss_default
value: float(300.0)
dss_name:
tag: dss_name
value: 'on'
description: Value at which the control arms to switch the capacitor ON (or ratchet
up a step). Default is 300 amps.
comments:
- 'Import: derived; targetValue = (ON + OFF) / 2, voltage x PTratio (V), current
x CTratio (A), kvar in kvar (targetValueUnitMultiplier k), time in hours; ON
on the wrong side of OFF raises; default 300. Export: targetValue -+ targetDeadband
/ 2, divided by the ratio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.targetValue
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
OFFsetting:
name: OFFsetting
annotations:
order:
tag: order
value: 8
dss_default:
tag: dss_default
value: float(200.0)
dss_name:
tag: dss_name
value: 'off'
description: Value at which the control arms to switch the capacitor OFF. Default
is 200 amps.
comments:
- 'Import: derived; targetDeadband = abs(OFF - ON), scaled as ONsetting; default
200. Export: targetValue +- targetDeadband / 2; an unset deadband raises.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.targetDeadband
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
Delay:
name: Delay
annotations:
order:
tag: order
value: 9
dss_default:
tag: dss_default
value: float(15.0)
description: Time delay, in seconds, from when the control is armed before it
sends the switching command to turn ON. Default is 15 s.
comments:
- 'Import: aVRDelay (s) on the compensator''s Update row; default 15. Export:
aVRDelay (s); unset -> not written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:ShuntCompensator.aVRDelay
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
- Fuse
- Recloser
- Relay
- Swtcontrol
range: float
required: false
VoltOverride:
name: VoltOverride
annotations:
order:
tag: order
value: 10
description: '{Yes | No} Default is No. If Yes, enables the VoltOverride feature
using Vmax and Vmin limits.'
comments:
- 'Import: untranscribed (a voltage override band of a kvar or current control;
maxAllowedTargetValue limits the target, not the voltage). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: boolean
required: false
Vmax:
name: Vmax
annotations:
order:
tag: order
value: 11
description: Maximum voltage, in volts, above which control is forced ON regardless
of control type setting.
comments:
- 'Import: untranscribed (the VoltOverride band, volts on the PT secondary). Export:
unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
Vmin:
name: Vmin
annotations:
order:
tag: order
value: 12
description: Minimum voltage, in volts, below which control is forced OFF regardless
of control type setting.
comments:
- 'Import: untranscribed (the VoltOverride band, volts on the PT secondary). Export:
unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
DelayOFF:
name: DelayOFF
annotations:
order:
tag: order
value: 13
dss_default:
tag: dss_default
value: float(15.0)
description: Time delay, in seconds, for control to turn OFF when present state
is ON. Default is 15 s.
comments:
- 'Import: untranscribed (CIM has one aVRDelay (Delay); DSS solution control).
Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
DeadTime:
name: DeadTime
annotations:
order:
tag: order
value: 14
description: Dead time after capacitor is turned OFF before it can be turned back
ON. Default is 300 s.
comments:
- 'Import: untranscribed (DSS solution control; no home in the network profile
parts). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
CTPhase:
name: CTPhase
annotations:
order:
tag: order
value: 15
description: Number of the phase being monitored for CURRENT control or one of
{AVG | MAX | MIN} for all phases. Default is 1.
comments:
- 'Import: raises when set (a CT phase); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: string
required: false
PTPhase:
name: PTPhase
annotations:
order:
tag: order
value: 16
dss_default:
tag: dss_default
value: int(1)
description: Number of the phase being monitored for VOLTAGE control or one of
{AVG | MAX | MIN} for all phases. Default is 1.
comments:
- 'Import: monitoredPhase = the phase of the monitored terminal''s conductor PTPhase
(default 1); AVG, MAX and MIN raise. Export: the 1-based place of monitoredPhase
among the monitored equipment''s conductors.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
close_mappings:
- cim:RegulatingControl.monitoredPhase
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: string
required: false
VBus:
name: VBus
annotations:
order:
tag: order
value: 17
description: Name of bus to use for voltage override function. Defaults to monitored
element bus.
comments:
- 'Import: raises when set (remote voltage sensing); no deck in the sweep sets
it, so a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: string
required: false
EventLog:
name: EventLog
annotations:
order:
tag: order
value: 18
description: '{Yes/True* | No/False} Default is YES for CapControl. If Yes, writes
switching events to a log.'
comments:
- 'Import: untranscribed (DSS report flag). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
- Expcontrol
- Invcontrol
- Regcontrol
- Relay
- Storagecontroller
range: boolean
required: false
UserModel:
name: UserModel
annotations:
order:
tag: order
value: 19
description: Name of DLL containing user-written CapControl model.
comments:
- 'Import: raises when set (a user model); no deck in the sweep sets it, so a
mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
owner: Capcontrol
domain_of:
- Generator
- Pvsystem
- Storage
- Windgen
- Capcontrol
range: string
required: false
UserData:
name: UserData
annotations:
order:
tag: order
value: 20
description: String that gets passed to the user-written CapControl model.
comments:
- 'Import: raises when set (user data); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
owner: Capcontrol
domain_of:
- Generator
- Pvsystem
- Storage
- Windgen
- Capcontrol
range: string
required: false
pctMinkvar:
name: pctMinkvar
annotations:
order:
tag: order
value: 21
description: For PF control option, min percent of total bank kvar at which control
will close capacitor switch. Default is 50.
comments:
- 'Import: untranscribed (used only by PF control, which raises). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: float
required: false
Reset:
name: Reset
annotations:
order:
tag: order
value: 22
description: '{Yes | No} If Yes, forces Reset of this CapControl.'
comments:
- 'Import: untranscribed (a command, not a setting). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
- Recloser
- Regcontrol
- Relay
- Swtcontrol
range: boolean
required: false
ControlSignal:
name: ControlSignal
annotations:
order:
tag: order
value: 23
description: Name of the load shape used for controlling the connection/disconnection
of the capacitor to the grid.
todos:
- Loadshape converter not yet implemented. ControlSignal LoadShape reference should
map to a CIM SeasonDayTypeSchedule.
comments:
- 'Import: raises when set (a control signal); no deck in the sweep sets it, so
a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
rank: 1000
owner: Capcontrol
domain_of:
- Capcontrol
range: string
required: false
basefreq:
name: basefreq
annotations:
order:
tag: order
value: 24
description: Base Frequency for ratings.
comments:
- 'Import: untranscribed (no home on a control). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
owner: Capcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: float
required: false
enabled:
name: enabled
annotations:
order:
tag: order
value: 25
dss_default:
tag: dss_default
value: 'true'
description: '{Yes|No or True|False} Indicates whether this element is enabled.'
comments:
- 'Import: the control''s enabled and the compensator''s controlEnabled; default
true. Export: the control''s enabled; the compensator''s must agree.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
exact_mappings:
- cim:RegulatingControl.enabled
- cim:RegulatingCondEq.controlEnabled
owner: Capcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: boolean
required: false
like:
name: like
annotations:
order:
tag: order
value: 26
description: 'Make like another object, e.g.: New Capcontrol.CC2 like=CC1 ...'
comments:
- 'Import: untranscribed; the reader resolves like= before mapping. Export: never
written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/capcontrol
owner: Capcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Cndata
- Dynamicexp
- Growthshape
- Linecode
- Linegeometry
- Linespacing
- Loadshape
- Priceshape
- Spectrum
- TccCurve
- Tsdata
- Tshape
- Wiredata
- Xfmrcode
- Xycurve
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: string
required: false
class_uri: dss:Capcontrol