Get/set the rated max power of the PV array for 1.0 kW/sq-m irradiance, kW.

URI: dss:Pmpp

Applicable Classes

Name Description Modifies Slot
Pvsystem A Pvsystem object in OpenDSS representing a photovoltaic generator with inver... no

Properties

Type and Range

Property Value
Range Float
Domain Of Pvsystem
### Slot Characteristics
Property Value
Owner Pvsystem

Comments

  • Import: copied to PhotoVoltaicUnit.maxP (kW); also p (pv_power); default 500. Export: the unit's maxP (kW), x 1/n for one of n phases; unset raises, a minP other than 0 raises.

Identifier and Mapping Information

Annotations

property value
order 5
dss_default float(500.0)

Schema Source

  • from schema: https://gridappsd.github.io/dss-graph/opendss

Mappings

Mapping Type Mapped Value
self dss:Pmpp
native dss:Pmpp
close cim:PowerElectronicsUnit.maxP

LinkML Source

name: Pmpp
annotations:
  order:
    tag: order
    value: 5
  dss_default:
    tag: dss_default
    value: float(500.0)
description: Get/set the rated max power of the PV array for 1.0 kW/sq-m irradiance,
  kW.
comments:
- 'Import: copied to PhotoVoltaicUnit.maxP (kW); also p (pv_power); default 500. Export:
  the unit''s maxP (kW), x 1/n for one of n phases; unset raises, a minP other than
  0 raises.'
from_schema: https://gridappsd.github.io/dss-graph/opendss
close_mappings:
- cim:PowerElectronicsUnit.maxP
rank: 1000
owner: Pvsystem
domain_of:
- Pvsystem
range: float
required: false