Class: Regcontrol¶
A Regcontrol object in OpenDSS representing a voltage regulator control that monitors a transformer winding and adjusts its tap to regulate voltage.
URI: dss:Regcontrol
classDiagram
class Regcontrol
click Regcontrol href "../Regcontrol/"
Regcontrol : band
Regcontrol : basefreq
Regcontrol : bus
Regcontrol : Cogen
Regcontrol : CTprim
Regcontrol : debugtrace
Regcontrol : delay
Regcontrol : enabled
Regcontrol : EventLog
Regcontrol : idle
Regcontrol : idleForward
Regcontrol : idleReverse
Regcontrol : inversetime
Regcontrol : LDC_Z
Regcontrol : like
Regcontrol : maxtapchange
Regcontrol : name
Regcontrol : PTphase
Regcontrol : ptratio
Regcontrol : R
Regcontrol : RemotePTRatio
Regcontrol : Reset
Regcontrol : rev_Z
Regcontrol : revband
Regcontrol : revDelay
Regcontrol : reversible
Regcontrol : revNeutral
Regcontrol : revR
Regcontrol : revThreshold
Regcontrol : revvreg
Regcontrol : revX
Regcontrol : tapdelay
Regcontrol : TapNum
Regcontrol : tapwinding
Regcontrol : transformer
Regcontrol : vlimit
Regcontrol : vreg
Regcontrol : winding
Regcontrol : X
Class Properties¶
| Property | Value |
|---|---|
| Class URI | dss:Regcontrol |
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| name | 1 String |
Object name | direct |
| transformer | 0..1 String |
Name of Transformer or AutoTrans element to which the RegControl is connected | direct |
| winding | 0..1 Integer |
Number of the winding of the transformer element that the RegControl is monit... | direct |
| vreg | 0..1 Float |
Voltage regulator setting, in VOLTS, for the winding being controlled | direct |
| band | 0..1 Float |
Bandwidth in VOLTS for the controlled bus (full bandwidth) | direct |
| ptratio | 0..1 Float |
Ratio of the PT that converts the controlled winding voltage to the regulator... | direct |
| CTprim | 0..1 Float |
Rating, in Amperes, of the primary CT rating for which the line amps convert ... | direct |
| R | 0..1 Float |
R setting on the line drop compensator in the regulator, expressed in VOLTS | direct |
| X | 0..1 Float |
X setting on the line drop compensator in the regulator, expressed in VOLTS | direct |
| bus | 0..1 String |
Name of a bus (busname | direct |
| delay | 0..1 Float |
Time delay, in seconds, from when the voltage goes out of band to when tap ch... | direct |
| reversible | 0..1 Boolean |
{Yes | No*} Indicates whether the regulator has a reverse operation mode |
| revvreg | 0..1 Float |
Voltage setting in volts for operation in the reverse direction | direct |
| revband | 0..1 Float |
Bandwidth for operating in the reverse direction | direct |
| revR | 0..1 Float |
R line drop compensator setting for reverse direction | direct |
| revX | 0..1 Float |
X line drop compensator setting for reverse direction | direct |
| tapdelay | 0..1 Float |
Delay in sec between tap changes | direct |
| debugtrace | 0..1 Boolean |
{Yes | No* } Default is no |
| maxtapchange | 0..1 Integer |
Maximum allowable tap change per control iteration in STATIC control mode | direct |
| inversetime | 0..1 Boolean |
{Yes | No* } Default is no |
| tapwinding | 0..1 Integer |
Winding containing the actual taps, if different than the WINDING property | direct |
| vlimit | 0..1 Float |
Voltage Limit for bus to which regulated winding is connected | direct |
| PTphase | 0..1 String |
For multi-phase transformers, the number of the phase being monitored or one ... | direct |
| revThreshold | 0..1 Float |
kW reverse power threshold for reversing the direction of the regulator | direct |
| revDelay | 0..1 Float |
Time Delay in seconds for executing the reversing action once the threshold f... | direct |
| revNeutral | 0..1 Boolean |
{Yes | No*} Default is no |
| EventLog | 0..1 Boolean |
{Yes/True* | No/False} Default is YES for regulator control |
| RemotePTRatio | 0..1 Float |
PT ratio required to convert actual voltage at the remote bus to control volt... | direct |
| TapNum | 0..1 Integer |
An integer number indicating the tap position that the controlled transformer... | direct |
| Reset | 0..1 Boolean |
{Yes | No} If Yes, forces Reset of this RegControl |
| LDC_Z | 0..1 Float |
Z value for Beckwith LDC_Z control option | direct |
| rev_Z | 0..1 Float |
Reverse Z value for Beckwith LDC_Z control option | direct |
| Cogen | 0..1 Boolean |
{Yes | No*} Default is No |
| idle | 0..1 Boolean |
{Yes | No*} Default is No |
| idleReverse | 0..1 Boolean |
{Yes | No*} Default is No |
| idleForward | 0..1 Boolean |
{Yes | No*} Default is No |
| basefreq | 0..1 Float |
Base Frequency for ratings | direct |
| enabled | 0..1 Boolean |
{Yes | No or True |
| like | 0..1 String |
Make like another object, e | direct |
Comments¶
- Import: one TapChangerControl rc_ + name and one RatioTapChanger rc_ + name + _tap (regcontrol.cimtbl) on the controlled end of the transformer it names (a VoltageRegulator's AutoTransformerEnd, or an LTC's PowerTransformerEnd). Export: one RegControl per TapChangerControl; another mode raises.
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridappsd.github.io/dss-graph/opendss
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | dss:Regcontrol |
| native | dss:Regcontrol |
| exact | cim:TapChangerControl |
| close | cim:RatioTapChanger |
LinkML Source¶
Direct¶
name: Regcontrol
description: A Regcontrol object in OpenDSS representing a voltage regulator control
that monitors a transformer winding and adjusts its tap to regulate voltage.
comments:
- 'Import: one TapChangerControl rc_ + name and one RatioTapChanger rc_ + name + _tap
(regcontrol.cimtbl) on the controlled end of the transformer it names (a VoltageRegulator''s
AutoTransformerEnd, or an LTC''s PowerTransformerEnd). Export: one RegControl per
TapChangerControl; another mode raises.'
from_schema: https://gridappsd.github.io/dss-graph/opendss
exact_mappings:
- cim:TapChangerControl
close_mappings:
- cim:RatioTapChanger
attributes:
name:
name: name
description: Object name. Must be unique per object type.
comments:
- 'Import: TapChangerControl.name and RatioTapChanger.name. Export: Names, the
RegControl namespace.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:IdentifiedObject.name
identifier: true
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Buscoords
- Cndata
- Dynamicexp
- Growthshape
- Linecode
- Linegeometry
- Linespacing
- Loadshape
- Priceshape
- Spectrum
- TccCurve
- Tsdata
- Tshape
- Wiredata
- Xfmrcode
- Xycurve
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Options
- Vsource
range: string
required: true
transformer:
name: transformer
annotations:
order:
tag: order
value: 1
description: Name of Transformer or AutoTrans element to which the RegControl
is connected.
comments:
- 'Import: structural; the regulator or LTC, a Transformer no New defines or two
RegControls name raises. Export: the DSS Transformer of the tap''s unit.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RatioTapChanger.TransformerEnd
rank: 1000
domain_of:
- Regcontrol
range: string
required: false
winding:
name: winding
annotations:
order:
tag: order
value: 2
dss_default:
tag: dss_default
value: int(1)
description: Number of the winding of the transformer element that the RegControl
is monitoring. Default is 1.
comments:
- 'Import: the end xf_<transformer>_<winding> holds the tap changer and its Terminal
is monitored; default 1. Export: the winding whose end holds the RatioTapChanger.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RatioTapChanger.TransformerEnd
- cim:RegulatingControl.Terminal
rank: 1000
domain_of:
- Regcontrol
range: integer
required: false
vreg:
name: vreg
annotations:
order:
tag: order
value: 3
dss_default:
tag: dss_default
value: float(120.0)
description: Voltage regulator setting, in VOLTS, for the winding being controlled.
Default is 120 V.
comments:
- 'Import: derived; targetValue (V) = vreg x ptratio (secondary_to_primary); default
120. Export: targetValue / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.targetValue
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
band:
name: band
annotations:
order:
tag: order
value: 4
dss_default:
tag: dss_default
value: float(3.0)
description: Bandwidth in VOLTS for the controlled bus (full bandwidth). Default
is 3 V.
comments:
- 'Import: derived; targetDeadband (V) = band x ptratio; default 3. Export: targetDeadband
/ ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.targetDeadband
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
ptratio:
name: ptratio
annotations:
order:
tag: order
value: 5
dss_default:
tag: dss_default
value: float(60.0)
description: Ratio of the PT that converts the controlled winding voltage to the
regulator control voltage. Default is 60.
comments:
- 'Import: ptRatio on the control and the tap changer; default 60. Export: ptRatio
(the two must agree; unset raises).'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:RegulatingControl.ptRatio
- cim:TapChanger.ptRatio
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
minimum_value: 0.0
CTprim:
name: CTprim
annotations:
order:
tag: order
value: 6
dss_default:
tag: dss_default
value: float(300.0)
description: Rating, in Amperes, of the primary CT rating for which the line amps
convert to control rated amps. Default is 300 A.
comments:
- 'Import: ctRating (A) = CTprim, ctRatio = CTprim / 0.2 (the DSS CT secondary);
default 300. Export: ctRating (A); ctRatio is not read.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChanger.ctRating
- cim:TapChanger.ctRatio
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
R:
name: R
annotations:
order:
tag: order
value: 7
dss_default:
tag: dss_default
value: float(0.0)
description: R setting on the line drop compensator in the regulator, expressed
in VOLTS.
comments:
- 'Import: derived; lineDropR (ohm) = R x ptratio / CTprim, compensation on when
R or X is nonzero. Export: lineDropR x CTprim / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.lineDropR
- cim:TapChangerControl.lineDropCompensation
domain_of:
- Gicline
- Capacitor
- Reactor
- Regcontrol
range: float
required: false
X:
name: X
annotations:
order:
tag: order
value: 8
dss_default:
tag: dss_default
value: float(0.0)
description: X setting on the line drop compensator in the regulator, expressed
in VOLTS.
comments:
- 'Import: derived; lineDropX (ohm) = X x ptratio / CTprim. Export: lineDropX
x CTprim / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.lineDropX
domain_of:
- Gicline
- Reactor
- Regcontrol
range: float
required: false
bus:
name: bus
annotations:
order:
tag: order
value: 9
description: Name of a bus (busname.nn.nn.nn) for remote voltage sensing. When
set, the regulator monitors this bus instead of the transformer winding.
comments:
- 'Import: raises when set (remote sensing); no deck in the sweep sets it, so
a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
domain_of:
- Autotrans
- Transformer
- Regcontrol
range: string
required: false
delay:
name: delay
annotations:
order:
tag: order
value: 10
dss_default:
tag: dss_default
value: float(15.0)
description: Time delay, in seconds, from when the voltage goes out of band to
when tap changing begins. Default is 15 s.
comments:
- 'Import: initialDelay (s); default 15. Export: initialDelay; unset -> not written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChanger.initialDelay
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
reversible:
name: reversible
annotations:
order:
tag: order
value: 11
dss_default:
tag: dss_default
value: 'false'
description: '{Yes |No*} Indicates whether the regulator has a reverse operation
mode.'
comments:
- 'Import: reversible; default false. Export: reversible.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChangerControl.reversible
rank: 1000
domain_of:
- Regcontrol
range: boolean
required: false
revvreg:
name: revvreg
annotations:
order:
tag: order
value: 12
dss_default:
tag: dss_default
value: float(120.0)
description: Voltage setting in volts for operation in the reverse direction.
Default is 120 V.
comments:
- 'Import: derived; reverseTargetValue (V) = revvreg x ptratio; default 120. Export:
reverseTargetValue / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.reverseTargetValue
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
revband:
name: revband
annotations:
order:
tag: order
value: 13
dss_default:
tag: dss_default
value: float(3.0)
description: Bandwidth for operating in the reverse direction. Default is 3 V.
comments:
- 'Import: derived; reverseTargetDeadband (V) = revband x ptratio; default 3.
Export: reverseTargetDeadband / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.reverseTargetDeadband
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
revR:
name: revR
annotations:
order:
tag: order
value: 14
dss_default:
tag: dss_default
value: float(0.0)
description: R line drop compensator setting for reverse direction.
comments:
- 'Import: derived; reverseLineDropR (ohm) = revR x ptratio / CTprim. Export:
reverseLineDropR x CTprim / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.reverseLineDropR
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
revX:
name: revX
annotations:
order:
tag: order
value: 15
dss_default:
tag: dss_default
value: float(0.0)
description: X line drop compensator setting for reverse direction.
comments:
- 'Import: derived; reverseLineDropX (ohm) = revX x ptratio / CTprim. Export:
reverseLineDropX x CTprim / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.reverseLineDropX
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
tapdelay:
name: tapdelay
annotations:
order:
tag: order
value: 16
dss_default:
tag: dss_default
value: float(2.0)
description: Delay in sec between tap changes. Default is 2 s.
comments:
- 'Import: subsequentDelay (s); default 2. Export: subsequentDelay; unset -> not
written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChanger.subsequentDelay
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
debugtrace:
name: debugtrace
annotations:
order:
tag: order
value: 17
description: '{Yes | No* } Default is no. If true, writes debug trace to file.'
comments:
- 'Import: untranscribed (DSS report flag). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
domain_of:
- Generator
- Pvsystem
- Storage
- Windgen
- Regcontrol
range: boolean
required: false
maxtapchange:
name: maxtapchange
annotations:
order:
tag: order
value: 18
description: Maximum allowable tap change per control iteration in STATIC control
mode. Default is 16.
comments:
- 'Import: untranscribed (DSS solution control; no home in the network profile
parts). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: integer
required: false
inversetime:
name: inversetime
annotations:
order:
tag: order
value: 19
description: '{Yes | No* } Default is no. If yes, time delays decrease inversely
with magnitude of voltage excursion.'
comments:
- 'Import: untranscribed (DSS solution control; no home in the network profile
parts). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: boolean
required: false
tapwinding:
name: tapwinding
annotations:
order:
tag: order
value: 20
description: Winding containing the actual taps, if different than the WINDING
property.
comments:
- 'Import: raises when set (a tap winding other than the monitored one); no deck
in the sweep sets it, so a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: integer
required: false
vlimit:
name: vlimit
annotations:
order:
tag: order
value: 21
dss_default:
tag: dss_default
value: float(0.0)
description: Voltage Limit for bus to which regulated winding is connected. Default
is 0 (no limit).
todos:
- 'Converter bug: uses tcc.limitVoltage (not a real TapChangerControl field) instead
of tcc.maxLimitVoltage on both import and export.'
comments:
- 'Import: raises when set to anything but its default 0 (no limit); no deck in
the sweep sets it, so a mapping waits for one. Export: a control with a voltage
limit raises.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.maxLimitVoltage
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
PTphase:
name: PTphase
annotations:
order:
tag: order
value: 22
dss_default:
tag: dss_default
value: int(1)
description: For multi-phase transformers, the number of the phase being monitored
or one of {MAX | MIN} for all phases. Default is 1.
comments:
- 'Import: monitoredPhase = the phase of the winding''s conductor PTphase (default
1); MAX and MIN raise. Export: the 1-based place of monitoredPhase among the
winding''s phase conductors.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.monitoredPhase
rank: 1000
domain_of:
- Regcontrol
range: string
required: false
revThreshold:
name: revThreshold
annotations:
order:
tag: order
value: 23
dss_default:
tag: dss_default
value: float(100.0)
description: kW reverse power threshold for reversing the direction of the regulator.
Default is 100 kW.
comments:
- 'Import: reversingPowerThreshold (kW); default 100. Export: reversingPowerThreshold
(kW).'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChangerControl.reversingPowerThreshold
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
revDelay:
name: revDelay
annotations:
order:
tag: order
value: 24
dss_default:
tag: dss_default
value: float(60.0)
description: Time Delay in seconds for executing the reversing action once the
threshold for reversing has been exceeded. Default is 60 s.
comments:
- 'Import: reversingDelay (s); default 60. Export: reversingDelay (s).'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChangerControl.reversingDelay
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
revNeutral:
name: revNeutral
annotations:
order:
tag: order
value: 25
dss_default:
tag: dss_default
value: 'false'
description: '{Yes | No*} Default is no. If yes, regulator goes to neutral tap
in reverse direction.'
comments:
- 'Import: reverseToNeutral; default false. Export: reverseToNeutral.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChangerControl.reverseToNeutral
rank: 1000
domain_of:
- Regcontrol
range: boolean
required: false
EventLog:
name: EventLog
annotations:
order:
tag: order
value: 26
description: '{Yes/True* | No/False} Default is YES for regulator control.'
comments:
- 'Import: untranscribed (DSS report flag). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
domain_of:
- Capcontrol
- Expcontrol
- Invcontrol
- Regcontrol
- Relay
- Storagecontroller
range: boolean
required: false
RemotePTRatio:
name: RemotePTRatio
annotations:
order:
tag: order
value: 27
description: PT ratio required to convert actual voltage at the remote bus to
control voltage when regulating a remote bus.
comments:
- 'Import: raises when set (remote sensing); no deck in the sweep sets it, so
a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
TapNum:
name: TapNum
annotations:
order:
tag: order
value: 28
description: An integer number indicating the tap position that the controlled
transformer winding tap position is currently at.
comments:
- 'Import: raises when set, even to 0 (a tap position that overrides the transformer''s
tap: setting it moves the tap, so it has no default); no deck in the sweep sets
it. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChanger.step
rank: 1000
domain_of:
- Regcontrol
range: integer
required: false
Reset:
name: Reset
annotations:
order:
tag: order
value: 29
description: '{Yes | No} If Yes, forces Reset of this RegControl.'
comments:
- 'Import: untranscribed (a command, not a setting). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
domain_of:
- Capcontrol
- Recloser
- Regcontrol
- Relay
- Swtcontrol
range: boolean
required: false
LDC_Z:
name: LDC_Z
annotations:
order:
tag: order
value: 30
dss_default:
tag: dss_default
value: float(0.0)
description: Z value for Beckwith LDC_Z control option. Complex impedance in ohms.
comments:
- 'Import: raises when set to anything but its default 0 (a line-drop impedance);
no deck in the sweep sets it, so a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
rev_Z:
name: rev_Z
annotations:
order:
tag: order
value: 31
dss_default:
tag: dss_default
value: float(0.0)
description: Reverse Z value for Beckwith LDC_Z control option.
comments:
- 'Import: raises when set to anything but its default 0 (a reverse line-drop
impedance); no deck in the sweep sets it, so a mapping waits for one. Export:
unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: float
required: false
Cogen:
name: Cogen
annotations:
order:
tag: order
value: 32
dss_default:
tag: dss_default
value: 'false'
description: '{Yes|No*} Default is No. Cogen mode — sets direction of power flow
sensing for reverse operation.'
comments:
- 'Import: raises when set to anything but its default No (cogeneration); no deck
in the sweep sets it, so a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: boolean
required: false
idle:
name: idle
annotations:
order:
tag: order
value: 33
description: '{Yes|No*} Default is No. If Yes, disables tap changing.'
comments:
- 'Import: raises when set (idle mode); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: boolean
required: false
idleReverse:
name: idleReverse
annotations:
order:
tag: order
value: 34
description: '{Yes|No*} Default is No. If Yes, disables tap changing in reverse
mode.'
comments:
- 'Import: raises when set (idle mode); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: boolean
required: false
idleForward:
name: idleForward
annotations:
order:
tag: order
value: 35
description: '{Yes|No*} Default is No. If Yes, disables tap changing in forward
mode.'
comments:
- 'Import: raises when set (idle mode); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
domain_of:
- Regcontrol
range: boolean
required: false
basefreq:
name: basefreq
annotations:
order:
tag: order
value: 36
description: Base Frequency for ratings.
comments:
- 'Import: untranscribed (no home on a control). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: float
required: false
enabled:
name: enabled
annotations:
order:
tag: order
value: 37
dss_default:
tag: dss_default
value: 'true'
description: '{Yes|No or True|False} Indicates whether this element is enabled.'
comments:
- 'Import: the control''s enabled and the tap''s controlEnabled; default true.
Export: the control''s enabled; the tap''s must agree.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:RegulatingControl.enabled
- cim:TapChanger.controlEnabled
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: boolean
required: false
like:
name: like
annotations:
order:
tag: order
value: 38
description: 'Make like another object, e.g.: New Regcontrol.RC2 like=RC1 ...'
comments:
- 'Import: untranscribed; the reader resolves like= before mapping. Export: never
written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Cndata
- Dynamicexp
- Growthshape
- Linecode
- Linegeometry
- Linespacing
- Loadshape
- Priceshape
- Spectrum
- TccCurve
- Tsdata
- Tshape
- Wiredata
- Xfmrcode
- Xycurve
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: string
required: false
class_uri: dss:Regcontrol
Induced¶
name: Regcontrol
description: A Regcontrol object in OpenDSS representing a voltage regulator control
that monitors a transformer winding and adjusts its tap to regulate voltage.
comments:
- 'Import: one TapChangerControl rc_ + name and one RatioTapChanger rc_ + name + _tap
(regcontrol.cimtbl) on the controlled end of the transformer it names (a VoltageRegulator''s
AutoTransformerEnd, or an LTC''s PowerTransformerEnd). Export: one RegControl per
TapChangerControl; another mode raises.'
from_schema: https://gridappsd.github.io/dss-graph/opendss
exact_mappings:
- cim:TapChangerControl
close_mappings:
- cim:RatioTapChanger
attributes:
name:
name: name
description: Object name. Must be unique per object type.
comments:
- 'Import: TapChangerControl.name and RatioTapChanger.name. Export: Names, the
RegControl namespace.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:IdentifiedObject.name
identifier: true
owner: Regcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Buscoords
- Cndata
- Dynamicexp
- Growthshape
- Linecode
- Linegeometry
- Linespacing
- Loadshape
- Priceshape
- Spectrum
- TccCurve
- Tsdata
- Tshape
- Wiredata
- Xfmrcode
- Xycurve
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Options
- Vsource
range: string
required: true
transformer:
name: transformer
annotations:
order:
tag: order
value: 1
description: Name of Transformer or AutoTrans element to which the RegControl
is connected.
comments:
- 'Import: structural; the regulator or LTC, a Transformer no New defines or two
RegControls name raises. Export: the DSS Transformer of the tap''s unit.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RatioTapChanger.TransformerEnd
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: string
required: false
winding:
name: winding
annotations:
order:
tag: order
value: 2
dss_default:
tag: dss_default
value: int(1)
description: Number of the winding of the transformer element that the RegControl
is monitoring. Default is 1.
comments:
- 'Import: the end xf_<transformer>_<winding> holds the tap changer and its Terminal
is monitored; default 1. Export: the winding whose end holds the RatioTapChanger.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RatioTapChanger.TransformerEnd
- cim:RegulatingControl.Terminal
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: integer
required: false
vreg:
name: vreg
annotations:
order:
tag: order
value: 3
dss_default:
tag: dss_default
value: float(120.0)
description: Voltage regulator setting, in VOLTS, for the winding being controlled.
Default is 120 V.
comments:
- 'Import: derived; targetValue (V) = vreg x ptratio (secondary_to_primary); default
120. Export: targetValue / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.targetValue
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
band:
name: band
annotations:
order:
tag: order
value: 4
dss_default:
tag: dss_default
value: float(3.0)
description: Bandwidth in VOLTS for the controlled bus (full bandwidth). Default
is 3 V.
comments:
- 'Import: derived; targetDeadband (V) = band x ptratio; default 3. Export: targetDeadband
/ ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.targetDeadband
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
ptratio:
name: ptratio
annotations:
order:
tag: order
value: 5
dss_default:
tag: dss_default
value: float(60.0)
description: Ratio of the PT that converts the controlled winding voltage to the
regulator control voltage. Default is 60.
comments:
- 'Import: ptRatio on the control and the tap changer; default 60. Export: ptRatio
(the two must agree; unset raises).'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:RegulatingControl.ptRatio
- cim:TapChanger.ptRatio
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
minimum_value: 0.0
CTprim:
name: CTprim
annotations:
order:
tag: order
value: 6
dss_default:
tag: dss_default
value: float(300.0)
description: Rating, in Amperes, of the primary CT rating for which the line amps
convert to control rated amps. Default is 300 A.
comments:
- 'Import: ctRating (A) = CTprim, ctRatio = CTprim / 0.2 (the DSS CT secondary);
default 300. Export: ctRating (A); ctRatio is not read.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChanger.ctRating
- cim:TapChanger.ctRatio
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
R:
name: R
annotations:
order:
tag: order
value: 7
dss_default:
tag: dss_default
value: float(0.0)
description: R setting on the line drop compensator in the regulator, expressed
in VOLTS.
comments:
- 'Import: derived; lineDropR (ohm) = R x ptratio / CTprim, compensation on when
R or X is nonzero. Export: lineDropR x CTprim / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.lineDropR
- cim:TapChangerControl.lineDropCompensation
owner: Regcontrol
domain_of:
- Gicline
- Capacitor
- Reactor
- Regcontrol
range: float
required: false
X:
name: X
annotations:
order:
tag: order
value: 8
dss_default:
tag: dss_default
value: float(0.0)
description: X setting on the line drop compensator in the regulator, expressed
in VOLTS.
comments:
- 'Import: derived; lineDropX (ohm) = X x ptratio / CTprim. Export: lineDropX
x CTprim / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.lineDropX
owner: Regcontrol
domain_of:
- Gicline
- Reactor
- Regcontrol
range: float
required: false
bus:
name: bus
annotations:
order:
tag: order
value: 9
description: Name of a bus (busname.nn.nn.nn) for remote voltage sensing. When
set, the regulator monitors this bus instead of the transformer winding.
comments:
- 'Import: raises when set (remote sensing); no deck in the sweep sets it, so
a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
owner: Regcontrol
domain_of:
- Autotrans
- Transformer
- Regcontrol
range: string
required: false
delay:
name: delay
annotations:
order:
tag: order
value: 10
dss_default:
tag: dss_default
value: float(15.0)
description: Time delay, in seconds, from when the voltage goes out of band to
when tap changing begins. Default is 15 s.
comments:
- 'Import: initialDelay (s); default 15. Export: initialDelay; unset -> not written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChanger.initialDelay
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
reversible:
name: reversible
annotations:
order:
tag: order
value: 11
dss_default:
tag: dss_default
value: 'false'
description: '{Yes |No*} Indicates whether the regulator has a reverse operation
mode.'
comments:
- 'Import: reversible; default false. Export: reversible.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChangerControl.reversible
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: boolean
required: false
revvreg:
name: revvreg
annotations:
order:
tag: order
value: 12
dss_default:
tag: dss_default
value: float(120.0)
description: Voltage setting in volts for operation in the reverse direction.
Default is 120 V.
comments:
- 'Import: derived; reverseTargetValue (V) = revvreg x ptratio; default 120. Export:
reverseTargetValue / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.reverseTargetValue
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
revband:
name: revband
annotations:
order:
tag: order
value: 13
dss_default:
tag: dss_default
value: float(3.0)
description: Bandwidth for operating in the reverse direction. Default is 3 V.
comments:
- 'Import: derived; reverseTargetDeadband (V) = revband x ptratio; default 3.
Export: reverseTargetDeadband / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.reverseTargetDeadband
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
revR:
name: revR
annotations:
order:
tag: order
value: 14
dss_default:
tag: dss_default
value: float(0.0)
description: R line drop compensator setting for reverse direction.
comments:
- 'Import: derived; reverseLineDropR (ohm) = revR x ptratio / CTprim. Export:
reverseLineDropR x CTprim / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.reverseLineDropR
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
revX:
name: revX
annotations:
order:
tag: order
value: 15
dss_default:
tag: dss_default
value: float(0.0)
description: X line drop compensator setting for reverse direction.
comments:
- 'Import: derived; reverseLineDropX (ohm) = revX x ptratio / CTprim. Export:
reverseLineDropX x CTprim / ptRatio.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.reverseLineDropX
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
tapdelay:
name: tapdelay
annotations:
order:
tag: order
value: 16
dss_default:
tag: dss_default
value: float(2.0)
description: Delay in sec between tap changes. Default is 2 s.
comments:
- 'Import: subsequentDelay (s); default 2. Export: subsequentDelay; unset -> not
written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChanger.subsequentDelay
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
debugtrace:
name: debugtrace
annotations:
order:
tag: order
value: 17
description: '{Yes | No* } Default is no. If true, writes debug trace to file.'
comments:
- 'Import: untranscribed (DSS report flag). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
owner: Regcontrol
domain_of:
- Generator
- Pvsystem
- Storage
- Windgen
- Regcontrol
range: boolean
required: false
maxtapchange:
name: maxtapchange
annotations:
order:
tag: order
value: 18
description: Maximum allowable tap change per control iteration in STATIC control
mode. Default is 16.
comments:
- 'Import: untranscribed (DSS solution control; no home in the network profile
parts). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: integer
required: false
inversetime:
name: inversetime
annotations:
order:
tag: order
value: 19
description: '{Yes | No* } Default is no. If yes, time delays decrease inversely
with magnitude of voltage excursion.'
comments:
- 'Import: untranscribed (DSS solution control; no home in the network profile
parts). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: boolean
required: false
tapwinding:
name: tapwinding
annotations:
order:
tag: order
value: 20
description: Winding containing the actual taps, if different than the WINDING
property.
comments:
- 'Import: raises when set (a tap winding other than the monitored one); no deck
in the sweep sets it, so a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: integer
required: false
vlimit:
name: vlimit
annotations:
order:
tag: order
value: 21
dss_default:
tag: dss_default
value: float(0.0)
description: Voltage Limit for bus to which regulated winding is connected. Default
is 0 (no limit).
todos:
- 'Converter bug: uses tcc.limitVoltage (not a real TapChangerControl field) instead
of tcc.maxLimitVoltage on both import and export.'
comments:
- 'Import: raises when set to anything but its default 0 (no limit); no deck in
the sweep sets it, so a mapping waits for one. Export: a control with a voltage
limit raises.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChangerControl.maxLimitVoltage
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
PTphase:
name: PTphase
annotations:
order:
tag: order
value: 22
dss_default:
tag: dss_default
value: int(1)
description: For multi-phase transformers, the number of the phase being monitored
or one of {MAX | MIN} for all phases. Default is 1.
comments:
- 'Import: monitoredPhase = the phase of the winding''s conductor PTphase (default
1); MAX and MIN raise. Export: the 1-based place of monitoredPhase among the
winding''s phase conductors.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:RegulatingControl.monitoredPhase
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: string
required: false
revThreshold:
name: revThreshold
annotations:
order:
tag: order
value: 23
dss_default:
tag: dss_default
value: float(100.0)
description: kW reverse power threshold for reversing the direction of the regulator.
Default is 100 kW.
comments:
- 'Import: reversingPowerThreshold (kW); default 100. Export: reversingPowerThreshold
(kW).'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChangerControl.reversingPowerThreshold
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
revDelay:
name: revDelay
annotations:
order:
tag: order
value: 24
dss_default:
tag: dss_default
value: float(60.0)
description: Time Delay in seconds for executing the reversing action once the
threshold for reversing has been exceeded. Default is 60 s.
comments:
- 'Import: reversingDelay (s); default 60. Export: reversingDelay (s).'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChangerControl.reversingDelay
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
revNeutral:
name: revNeutral
annotations:
order:
tag: order
value: 25
dss_default:
tag: dss_default
value: 'false'
description: '{Yes | No*} Default is no. If yes, regulator goes to neutral tap
in reverse direction.'
comments:
- 'Import: reverseToNeutral; default false. Export: reverseToNeutral.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:TapChangerControl.reverseToNeutral
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: boolean
required: false
EventLog:
name: EventLog
annotations:
order:
tag: order
value: 26
description: '{Yes/True* | No/False} Default is YES for regulator control.'
comments:
- 'Import: untranscribed (DSS report flag). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
owner: Regcontrol
domain_of:
- Capcontrol
- Expcontrol
- Invcontrol
- Regcontrol
- Relay
- Storagecontroller
range: boolean
required: false
RemotePTRatio:
name: RemotePTRatio
annotations:
order:
tag: order
value: 27
description: PT ratio required to convert actual voltage at the remote bus to
control voltage when regulating a remote bus.
comments:
- 'Import: raises when set (remote sensing); no deck in the sweep sets it, so
a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
TapNum:
name: TapNum
annotations:
order:
tag: order
value: 28
description: An integer number indicating the tap position that the controlled
transformer winding tap position is currently at.
comments:
- 'Import: raises when set, even to 0 (a tap position that overrides the transformer''s
tap: setting it moves the tap, so it has no default); no deck in the sweep sets
it. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
close_mappings:
- cim:TapChanger.step
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: integer
required: false
Reset:
name: Reset
annotations:
order:
tag: order
value: 29
description: '{Yes | No} If Yes, forces Reset of this RegControl.'
comments:
- 'Import: untranscribed (a command, not a setting). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
owner: Regcontrol
domain_of:
- Capcontrol
- Recloser
- Regcontrol
- Relay
- Swtcontrol
range: boolean
required: false
LDC_Z:
name: LDC_Z
annotations:
order:
tag: order
value: 30
dss_default:
tag: dss_default
value: float(0.0)
description: Z value for Beckwith LDC_Z control option. Complex impedance in ohms.
comments:
- 'Import: raises when set to anything but its default 0 (a line-drop impedance);
no deck in the sweep sets it, so a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
rev_Z:
name: rev_Z
annotations:
order:
tag: order
value: 31
dss_default:
tag: dss_default
value: float(0.0)
description: Reverse Z value for Beckwith LDC_Z control option.
comments:
- 'Import: raises when set to anything but its default 0 (a reverse line-drop
impedance); no deck in the sweep sets it, so a mapping waits for one. Export:
unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: float
required: false
Cogen:
name: Cogen
annotations:
order:
tag: order
value: 32
dss_default:
tag: dss_default
value: 'false'
description: '{Yes|No*} Default is No. Cogen mode — sets direction of power flow
sensing for reverse operation.'
comments:
- 'Import: raises when set to anything but its default No (cogeneration); no deck
in the sweep sets it, so a mapping waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: boolean
required: false
idle:
name: idle
annotations:
order:
tag: order
value: 33
description: '{Yes|No*} Default is No. If Yes, disables tap changing.'
comments:
- 'Import: raises when set (idle mode); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: boolean
required: false
idleReverse:
name: idleReverse
annotations:
order:
tag: order
value: 34
description: '{Yes|No*} Default is No. If Yes, disables tap changing in reverse
mode.'
comments:
- 'Import: raises when set (idle mode); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: boolean
required: false
idleForward:
name: idleForward
annotations:
order:
tag: order
value: 35
description: '{Yes|No*} Default is No. If Yes, disables tap changing in forward
mode.'
comments:
- 'Import: raises when set (idle mode); no deck in the sweep sets it, so a mapping
waits for one. Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
rank: 1000
owner: Regcontrol
domain_of:
- Regcontrol
range: boolean
required: false
basefreq:
name: basefreq
annotations:
order:
tag: order
value: 36
description: Base Frequency for ratings.
comments:
- 'Import: untranscribed (no home on a control). Export: unset.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
owner: Regcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: float
required: false
enabled:
name: enabled
annotations:
order:
tag: order
value: 37
dss_default:
tag: dss_default
value: 'true'
description: '{Yes|No or True|False} Indicates whether this element is enabled.'
comments:
- 'Import: the control''s enabled and the tap''s controlEnabled; default true.
Export: the control''s enabled; the tap''s must agree.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
exact_mappings:
- cim:RegulatingControl.enabled
- cim:TapChanger.controlEnabled
owner: Regcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: boolean
required: false
like:
name: like
annotations:
order:
tag: order
value: 38
description: 'Make like another object, e.g.: New Regcontrol.RC2 like=RC1 ...'
comments:
- 'Import: untranscribed; the reader resolves like= before mapping. Export: never
written.'
from_schema: https://gridappsd.github.io/dss-graph/controls/regcontrol
owner: Regcontrol
domain_of:
- Load
- Generator
- Generic5
- Gicline
- Indmach012
- Pvsystem
- Storage
- Upfc
- Vccs
- Vsconverter
- Windgen
- Autotrans
- Capacitor
- Gictransformer
- Line
- Reactor
- Transformer
- Capcontrol
- Espvlcontrol
- Expcontrol
- Fuse
- Gendispatcher
- Invcontrol
- Pycontrol
- Recloser
- Regcontrol
- Relay
- Storagecontroller
- Swtcontrol
- Upfccontrol
- Cndata
- Dynamicexp
- Growthshape
- Linecode
- Linegeometry
- Linespacing
- Loadshape
- Priceshape
- Spectrum
- TccCurve
- Tsdata
- Tshape
- Wiredata
- Xfmrcode
- Xycurve
- Energymeter
- Fmonitor
- Monitor
- Sensor
- Fault
- Gicsource
- Isource
- Vsource
range: string
required: false
class_uri: dss:Regcontrol