Import: copied to SynchronousMachine.maxQ (kVAr); model 3 only (another model raises); default 2 x kvar, reset by each kW, pf or kvar assignment (reactive_limits). Export: model 3: maxQ (kVAr); unset -> not written.
name:maxkvarannotations:order:tag:ordervalue:21description:Maximum kvar limit for Model = 3. Defaults to twice the specified loadkvar.comments:-'Import:copiedtoSynchronousMachine.maxQ(kVAr);model3only(anothermodelraises);default2xkvar,resetbyeachkW,pforkvarassignment(reactive_limits).Export:model3:maxQ(kVAr);unset->notwritten.'from_schema:https://gridappsd.github.io/dss-graph/opendssexact_mappings:-cim:SynchronousMachine.maxQrank:1000owner:Generatordomain_of:-Generatorrange:floatrequired:false