Architecture¶
The package is cimhub_raw, under
cimhub_raw/src/cimhub_raw/.
It has four parts, one per core ABC, plus the schema they share. The hub and spoke layout, and what core holds, are
on the core site's converter API page.
flowchart TB
schema["schema/raw_v34/<br/>raw34_schema.py + YAML + composite_id.py"]
layout["record_layout.py<br/>field positions from the annotations"] --> schema
reader["raw34_reader.py"] --> layout
writer["raw34_writer.py"] --> layout
reader --> schema
importer["importer/<br/>raw_to_cimtbl.py, topology.py, node_breaker.py,<br/>cimtbl/*.py"] --> reader
exporter["exporter/<br/>cim_to_raw.py + one module per RAW table"] --> writer
exporter -.->|"prefixes, derived values, islands"| importer
core["cimhub_core<br/>base, cimtbl, getters, export_slots"]
importer --> core
exporter --> core
reader --> core
writer --> core
topo["cimtopology.core"] --> importer
The importer reads the GraphModel the reader builds. The exporter returns a GraphModel of the same record classes,
and cim_to_raw hands it to the writer. The exporter imports from the importer so that a rule is written once: the
mRID prefixes (importer.cimtbl.fixed_shunt.PREFIX), the derived functions and their inverses
(derived.per_unit_from_mva and mva_from_per_unit), the rating-set type names, and topology.islands for the area
trace. The importer never imports from the exporter.
How the four ABCs are implemented¶
| Core class | Here | Entry point |
|---|---|---|
FormatReader |
Raw34Reader(source) binds a .raw path; read_all() parses the file once and returns a GraphModel. |
Raw34Reader(path).read_all() |
FormatWriter |
Raw34Writer: write(model, destination) writes the case file; lines(model) returns its lines; serialize(obj) returns one record as RAW text. |
Raw34Writer().write(model, "out.raw") |
CimtblImporter |
RawImporter(name, *, authority) implements to_cimtbl; to_cim and bound_parts are core's (no bound parts). model_cls is BusBranchModel. |
raw_to_cim(model, name=...) |
FormatExporter |
RawExporter().to_model(network) returns a GraphModel of RAW records. |
cim_to_raw(network, "out.raw") |
raw_to_cim and cim_to_raw build the object and make the one call; cim_to_raw then writes the model with
Raw34Writer. RawImporter.to_cim takes a parsed model and never a path; cim_to_raw takes a destination because
writing is its job. The package __init__.py is empty, so import from the modules named below. The class-level
contracts are in the core
converter API.
Why a BusBranchModel¶
A RAW case is a bus-branch model: every device names the buses at its ends, and a bus is a number. The importer
therefore sets RawImporter.model_cls = BusBranchModel, and each RAW bus becomes a TopologicalNode (mRID the bare bus
number) with a BusbarSection; every device terminal is on a TopologicalNode. The exporter relies on the same
shape: a bus number is TopologicalNode.busNumber, and a device's end buses are its terminals' nodes in
sequenceNumber order (identity.terminal_buses).
Substations are not in RAW's bus section, so the importer synthesizes them: buses joined by equipment that sits
inside a substation (switches, zero-impedance branches, series capacitors, transformers) form one Substation
(importer/topology.py). The substation is the equipment container of everything at its buses.
A SUBSTATION block (RAW's node-breaker data) adds detail inside a bus. Its nodes become ConnectivityNodes, each
inside its bus's TopologicalNode; its switching devices become Switch, Breaker or Disconnectors between nodes;
and its equipment terminal records move each named Terminal from the bus to its node with Update rows
(equipment_terminal.cimtbl). The model is still a BusBranchModel: the bus stays the unit of the network, and the
nodes sit inside it. A block's buses always form one substation, named sub_s<IS>.
Module map¶
Top level¶
| Module | What it does | Depends on |
|---|---|---|
raw34_reader.py |
Raw34Reader, Raw34ParseError, SECTIONS, tokenize: a .raw file to a GraphModel. |
record_layout, composite_id, schema, cimhub_core (GraphModel, base) |
raw34_writer.py |
Raw34Writer, format_field, format_line, format_record: a GraphModel to a .raw file. |
raw34_reader (SECTIONS and the phase-2 set), record_layout, schema |
record_layout.py |
Slot, record_lines, line_count, terminal_slots: the positional layout of each record, from the schema annotations, shared by reader and writer. |
schema, cimhub_core.serialization |
schema/raw_v34/raw34_schema.py |
The generated dataclasses, one per RAW record type. Never edited by hand. | linkml_runtime |
schema/raw_v34/*.yaml |
The LinkML YAML the module is generated from, and the annotations the code reads. | |
schema/raw_v34/composite_id.py |
assign_composite_id, KEY_FIELDS: the natural key of each record type, set as record.ID. |
schema, cimhub_core.serialization |
Importer¶
| Module | What it does | Depends on |
|---|---|---|
importer/raw_to_cimtbl.py |
RawImporter, raw_to_cim, MAPPING_ORDER, Site, map_master: the orchestrator. |
every mapper, topology, node_breaker, cimhub_core |
importer/topology.py |
substation_groups, SubstationGroup, untraced_area_buses, islands: the substations of a bus-branch case. |
cimtopology.core, schema |
importer/node_breaker.py |
NodeBreaker, node_mrid, node_busbar_mrid: which SUBSTATION block each bus is in, each block's nodes, and the terminal a control regulating a node names. |
schema, importer/cimtbl/bus |
Each mapper in importer/cimtbl/ has a NATIVE_CLASS, a FIELDS classification and a map_<table>(native, ...)
function that returns one Document. Shared helpers come first, then the mappers.
| Module | RAW table | Output file | Also depends on |
|---|---|---|---|
records.py |
not a table: raw_defaults, fill_keyed_defaults, listed_off_default |
cimhub_core.cimtbl |
|
derived.py |
not a table: the named, tested derived values and their inverses (kv_from_per_unit, ka_from_rating, per_unit_from_mva, transformer_ohms, ratio_tap, zip_mix, ...) |
cimprofiles.units |
|
ratings.py |
not a table: the twelve rating-set OperationalLimitTypes and RatingRows, the limit rows of a rated device |
master and the device documents |
derived |
tie_flow.py |
not a table: the TieFlow pairs of a device whose ends are in two areas |
area_interchange |
|
dc_topology.py |
not a table: the DCLine, DCTopologicalNodes and converter DC terminals of a DC line |
||
phase2.py |
not a table: not_mapped_yet, the shared body of the stubs |
||
case_identification.py |
Case identification and system-wide data (case_values, case_record) |
the master | |
zone.py |
Zone | zone |
|
area_interchange.py |
Area interchange | area_interchange |
interarea_transfer, derived |
interarea_transfer.py |
Inter-area transfer: no artifact, listed on the ControlArea comment |
||
owner.py |
Owner: no artifact (a CIM 18 gap) | ||
bus.py |
Bus | bus |
topology, zone, derived |
substation.py |
SUBSTATION nodes and switching devices (NODE_FIELDS, DEVICE_FIELDS) |
substation |
bus, switch, ratings, node_breaker |
branch.py |
Branch | branch |
ratings, tie_flow, area_interchange |
switch.py |
System switching device | switch |
ratings, tie_flow |
multi_section_line.py |
Multi-section line | multi_section_line |
branch, zone |
load.py |
Load | load |
area_interchange, derived |
fixed_shunt.py |
Fixed shunt | fixed_shunt |
derived |
generator.py |
Generator | generator |
area_interchange, derived |
impedance_correction.py |
Transformer impedance correction (NATIVE_CLASS, POINT_CLASS) |
impedance_correction |
derived |
transformer.py |
Transformer | transformer |
impedance_correction, ratings, tie_flow, derived |
two_terminal_dc.py |
Two-terminal DC line | two_terminal_dc |
area_interchange, dc_topology, derived, tie_flow |
vsc_dc.py |
VSC DC line | vsc_dc |
area_interchange, dc_topology, derived, ratings, tie_flow, node_breaker |
facts_device.py |
FACTS device (a shunt-only device) | facts_device |
node_breaker, derived |
switched_shunt.py |
Switched shunt | switched_shunt |
generator, facts_device, derived |
equipment_terminal.py |
SUBSTATION equipment terminals | equipment_terminal |
every equipment mapper's mRID prefix, node_breaker |
multi_terminal_dc.py, gne_device.py, induction_machine.py |
the three phase-2 stubs: an empty document, or NotImplementedError when the case has records |
none | phase2 |
Exporter¶
| Module | What it does | Depends on |
|---|---|---|
exporter/cim_to_raw.py |
RawExporter, cim_to_raw, EXPORT_ORDER, ExportContext, export_context, export_tables: runs each module over the network, assigns the composite IDs and refuses equipment no module exports. |
every module below, Raw34Writer |
exporter/identity.py |
bus_numbers, keyed_numbers, terminal_buses, keyed_ids, raw_name: bus, zone and area numbers, device IDs and NAMEs from the mRIDs the importer wrote. |
cimhub_core.getters |
exporter/area_trace.py |
trace_areas, metered_terminal: each bus's AREA, traced from generating units and tie flows. |
importer/topology (islands) |
exporter/ratings.py |
device_limits, device_ratings, ratings_in_current, rating_set_number: RATE1..RATE12 and the case's rating units. |
getters.limits_by_type, getters.base_voltage, importer/cimtbl/ratings, derived |
exporter/shunt_admittance.py |
bus_base_admittance: a shunt's g and b in pu on its bus's base. |
getters.shunt |
The export modules proper. Each has NATIVE_CLASS, CIM_CLASSES, SLOTS and export(context):
| Module | CIM class | RAW record |
|---|---|---|
case_identification.py |
BasePower, BaseFrequency, the rating-set types (CIM_CLASSES is empty) |
Case identification, Rating |
zone.py |
SubGeographicalRegion (empty) |
Zone |
area_interchange.py |
ControlArea (empty) |
Area interchange |
bus.py |
BusbarSection (each numbered TopologicalNode) |
Bus |
branch.py |
ACLineSegment, SeriesCompensator (with their line shunts and ratings) |
Branch |
switch.py |
Switch, Breaker, Disconnector |
System switching device |
multi_section_line.py |
Line (empty: a container) |
Multi-section line |
load.py |
EnergyConsumer, ConformLoad, NonConformLoad |
Load |
fixed_shunt.py |
LinearShuntCompensator with no control |
Fixed shunt |
switched_shunt.py |
LinearShuntCompensators under one RegulatingControl |
Switched shunt |
generator.py |
SynchronousMachine, PowerElectronicsConnection (with the step-up folded back) |
Generator |
transformer.py |
PowerTransformer |
Transformer |
impedance_correction.py |
ImpedanceTapChangerTable (empty) |
Impedance correction |
Boundaries¶
- No module in
importer/orexporter/opens a file.raw_to_cimwrites the artifact only through core'sto_cim, andcim_to_rawwrites only throughRaw34Writer. - Field positions, widths and quoting live in the schema annotations, read through
record_layout. Neither the reader nor the writer hard-codes a column. - A record's key is
composite_id.assign_composite_id, called by the reader when it adds a record and byexport_tableswhen it adds an exported one, so the key that seeds an mRID on import is the key an exported record has. - The importer fills RAW's defaults and lists them in a
defaulted:comment; the reader does not default anything (the one exception is a blank key field, see Reader and writer).