| a |
A - Load torque coefficient A (WECC model only) |
| acset_1 |
ACSET - (converter 1) AC voltage setpoint in pu (MODE 1) or power factor setp... |
| acset_2 |
ACSET - (converter 2) AC voltage setpoint in pu (MODE 1) or power factor setp... |
| adjm |
ADJM - Adjustment method (0 switch in input order, 1 next highest or lowest t... |
| adjust |
ADJUST record |
| aloss_1 |
ALOSS - (converter 1) Constant converter loss coefficient in kW |
| aloss_2 |
ALOSS - (converter 2) Constant converter loss coefficient in kW |
| ang1 |
ANG1 - Winding 1 phase shift angle in degrees |
| ang2 |
ANG2 - Winding 2 phase shift angle in degrees |
| ang3 |
ANG3 - Winding 3 phase shift angle in degrees |
| angmn |
ANGMN - Minimum steady-state ALPHA or GAMMA firing angle in degrees |
| angmx |
ANGMX - Nominal maximum ALPHA or GAMMA firing angle in degrees |
| anmni |
ANMNI - Inverter minimum steady-state gamma angle in degrees |
| anmnr |
ANMNR - Rectifier minimum steady-state firing angle in degrees |
| anmxi |
ANMXI - Inverter nominal maximum gamma angle in degrees |
| anmxr |
ANMXR - Rectifier nominal maximum firing angle in degrees |
| anstar |
ANSTAR - Star point voltage angle in degrees |
| area |
AREA - Area number |
| area_interchange_records |
Area interchange data records |
| area_number |
I - Area number |
| b |
B - Total branch charging susceptance in pu |
| b1 |
B1 - Admittance increment for each step in block 1 in Mvar at unity voltage |
| b2 |
B2 - Admittance increment for each step in block 2 in Mvar at unity voltage |
| b3 |
B3 - Admittance increment for each step in block 3 in Mvar at unity voltage |
| b4 |
B4 - Admittance increment for each step in block 4 in Mvar at unity voltage |
| b5 |
B5 - Admittance increment for each step in block 5 in Mvar at unity voltage |
| b6 |
B6 - Admittance increment for each step in block 6 in Mvar at unity voltage |
| b7 |
B7 - Admittance increment for each step in block 7 in Mvar at unity voltage |
| b8 |
B8 - Admittance increment for each step in block 8 in Mvar at unity voltage |
| b_from |
BI - Complex admittance of line shunt at from bus, susceptance component in p... |
| b_to |
BJ - Complex admittance of line shunt at to bus, susceptance component in pu |
| base_voltage |
BASKV - Bus base voltage in kV |
| bcode |
BC - Machine base power code (1 mechanical MW, 2 electrical MVA) |
| binit |
BINIT - Initial switched shunt admittance in Mvar at unity voltage |
| bl |
BL - Reactive component of shunt admittance in MVAr at 1 |
| bloss_1 |
BLOSS - (converter 1) Linear converter loss coefficient in kW per ampere of D... |
| bloss_2 |
BLOSS - (converter 2) Linear converter loss coefficient in kW per ampere of D... |
| branch_ratings_units |
NXFRAT - Non-transformer branch ratings units flag (<=0 MVA, >0 current as MV... |
| branch_records |
Branch (line) data records |
| bus_id |
I - Bus number or extended bus name |
| bus_number |
I - Bus number (1-999997) |
| bus_numbers |
BUS1 |
| bus_records |
Bus data records |
| bus_type |
IDE - Bus type code (1=PQ, 2=PV, 3=swing, 4=isolated) |
| case_record |
Case identification record |
| cccacc |
CCCACC - Acceleration factor for capacitor commutated line Newton solution |
| cccitmx |
CCCITMX - Iteration limit for capacitor commutated line Newton solution |
| character_data |
CHAR1 |
| circuit |
CKT - Circuit identifier |
| ckt |
CKT - One-character circuit identifier |
| cm |
CM - Magnetizing admittance I/O code |
| cnvcod |
CNVCOD - Converter code (zero or positive for positive pole, negative for neg... |
| cnxa1 |
CNXA1 - Winding 1 connection angle in degrees |
| cnxa2 |
CNXA2 - Winding 2 connection angle in degrees |
| cnxa3 |
CNXA3 - Winding 3 connection angle in degrees |
| cod1 |
COD1 - Winding 1 control mode |
| cod2 |
COD2 - Winding 2 control mode |
| cod3 |
COD3 - Winding 3 control mode |
| constant_admittance_imag_power |
YQ - Reactive power component of constant admittance load in MVAr |
| constant_admittance_real_power |
YP - Active power component of constant admittance load in MW |
| constant_current_imag_power |
IQ - Reactive power component of constant current load in MVAr |
| constant_current_real_power |
IP - Active power component of constant current load in MW |
| constant_imag_power |
QL - Reactive power component of constant MVA load in MVAr |
| constant_real_power |
PL - Active power component of constant MVA load in MW |
| cont1 |
CONT1 - Winding 1 controlled bus number |
| cont2 |
CONT2 - Winding 2 controlled bus number |
| cont3 |
CONT3 - Winding 3 controlled bus number |
| converter_type_1 |
TYPE - (converter 1) Converter DC control code (0=out of service, 1=DC voltag... |
| converter_type_2 |
TYPE - (converter 2) Converter DC control code (0=out of service, 1=DC voltag... |
| cr1 |
CR1 - Winding 1 load drop compensation resistance in pu |
| cr2 |
CR2 - Winding 2 load drop compensation resistance in pu |
| cr3 |
CR3 - Winding 3 load drop compensation resistance in pu |
| cw |
CW - Winding data I/O code |
| cx1 |
CX1 - Winding 1 load drop compensation reactance in pu |
| cx2 |
CX2 - Winding 2 load drop compensation reactance in pu |
| cx3 |
CX3 - Winding 3 load drop compensation reactance in pu |
| cz |
CZ - Impedance data I/O code |
| d |
D - Load torque coefficient D (power law exponent term, or WECC) |
| dcname |
DCNAME - DC bus name (12 characters) |
| dcode |
DC - Machine design code (0 custom, 1-5 NEMA or IEC design) |
| dcpf |
DCPF - Converter participation factor for sharing order reductions on the sam... |
| dcset_1 |
DCSET - (converter 1) DC voltage setpoint (TYPE 1) or power demand (TYPE 2, +... |
| dcset_2 |
DCSET - (converter 2) DC voltage setpoint (TYPE 1) or power demand (TYPE 2, +... |
| dcvmin |
DCVMIN - Minimum compounded DC voltage in kV |
| delti |
DELTI - Margin as per-unit fraction of desired DC power or current |
| device_type |
TYPE - Switching device type (1 generic connector, 2 circuit breaker, 3 disco... |
| dgenf |
DGENM - Distributed generation operation mode (0=off, 1=on) |
| dgenp |
DGENP - Distributed generation active power in MW |
| dgenq |
DGENQ - Distributed generation reactive power in MVAr |
| dum1 |
DUM1 - Dummy bus number 1 (between sections 1 and 2); at least one dummy bus ... |
| dum2 |
DUM2 - Dummy bus number 2 (between sections 2 and 3) |
| dum3 |
DUM3 - Dummy bus number 3 (between sections 3 and 4) |
| dum4 |
DUM4 - Dummy bus number 4 (between sections 4 and 5) |
| dum5 |
DUM5 - Dummy bus number 5 (between sections 5 and 6) |
| dum6 |
DUM6 - Dummy bus number 6 (between sections 6 and 7) |
| dum7 |
DUM7 - Dummy bus number 7 (between sections 7 and 8) |
| dum8 |
DUM8 - Dummy bus number 8 (between sections 8 and 9) |
| dum9 |
DUM9 - Dummy bus number 9 (between sections 9 and 10) |
| e |
E - Load torque coefficient E (WECC model only) |
| e1 |
E1 - First terminal voltage point on the saturation curve in pu on RATEKV |
| e2 |
E2 - Second terminal voltage point on the saturation curve in pu on RATEKV |
| ebas |
EBAS - Primary base AC voltage in kV |
| ebasi |
EBASI - Inverter primary base AC voltage in kV |
| ebasr |
EBASR - Rectifier primary base AC voltage in kV |
| emergency_voltage_magnitude_high_limit |
EVHI - Emergency voltage magnitude high limit in pu |
| emergency_voltage_magnitude_low_limit |
EVLO - Emergency voltage magnitude low limit in pu |
| equipment_terminal_records |
Equipment terminal records (equipment ends placed on nodes) |
| f1 |
F1 - Fraction of ownership for owner 1 |
| f2 |
F2 - Fraction of ownership for owner 2 |
| f3 |
F3 - Fraction of ownership for owner 3 |
| f4 |
F4 - Fraction of ownership for owner 4 |
| f_imag |
Im(Fi) - Imaginary part of the impedance scaling factor |
| f_real |
Re(Fi) - Real part of the impedance scaling factor |
| facts_device_records |
FACTS device data records |
| fixed_shunt_records |
Fixed shunt data records |
| from_area |
ARFROM - From area number |
| from_bus_number |
I - From bus number |
| from_node |
NI - From node number (1 through 999), must be in the substation |
| g_from |
GI - Complex admittance of line shunt at from bus, conductance component in p... |
| g_to |
GJ - Complex admittance of line shunt at to bus, conductance component in pu |
| gauss |
GAUSS record |
| gen_id |
ID - Generator identifier (1 or 2 characters) |
| general |
GENERAL record |
| generator_records |
Generator data records |
| gl |
GL - Active component of shunt admittance in MW at 1 |
| gne_device_records |
General network element device data records |
| grounding_resistance |
SRG - Substation grounding DC resistance in ohms |
| gtap |
GTAP - Step-up transformer off-nominal turns ratio |
| h |
H - Machine inertia in pu on MBASE |
| i |
I - Winding 1 bus number |
| ia1 |
IA1 - First stator current in pu for stator leakage saturation |
| ia2 |
IA2 - Second stator current in pu for stator leakage saturation |
| ib |
IB - AC converter bus number |
| ibus |
I - Sending end bus number or extended bus name |
| ibus_1 |
IBUS - (converter 1) Converter bus number |
| ibus_2 |
IBUS - (converter 2) Converter bus number |
| ici |
ICI - Inverter commutating bus number (firing angle reference bus, 0=none) |
| icr |
ICR - Rectifier commutating bus number (firing angle reference bus, 0=none) |
| idc |
IDC - DC bus number (1 to NDCBS) |
| idc2 |
IDC2 - Second DC bus the converter connects to (0 if connected directly to gr... |
| identifier |
ID, CKT or NAME - Equipment identifier for L, F, M, I, B, 2 and 3 forms; equi... |
| idi |
IDI - Inverter transformer circuit identifier |
| idr |
IDR - Rectifier transformer circuit identifier |
| ifi |
IFI - Inverter transformer winding 1 side bus number (0=none) |
| ifr |
IFR - Rectifier transformer winding 1 side bus number (0=none) |
| imax_1 |
IMAX - (converter 1) Converter AC current rating in amperes (0 = unlimited) |
| imax_2 |
IMAX - (converter 2) Converter AC current rating in amperes (0 = unlimited) |
| impedance_correction_records |
Transformer impedance correction table data records |
| imx |
IMX - Maximum series current in MVA at unity voltage (0 for no limit) |
| induction_machine_records |
Induction machine data records |
| integer_data |
INTG1 |
| interarea_transfer_records |
Interarea transfer data records |
| interruptible |
INTRPT - Interruptible load flag |
| ipi |
IPI - Inverter converter bus number |
| ipr |
IPR - Rectifier converter bus number |
| iti |
ITI - Inverter transformer winding 2 side bus number (0=none) |
| itr |
ITR - Rectifier transformer winding 2 side bus number (0=none) |
| j |
J - Winding 2 bus number |
| j_bus |
J - To bus number or extended bus name (branch and transformer forms only) |
| jbus |
J - Terminal end bus number or extended bus name (0 for a STATCON) |
| jdc |
JDC - To DC bus number |
| k |
K - Winding 3 bus number (0 for 2-winding) |
| k_bus |
K - Third bus number or extended bus name (three-winding transformer form onl... |
| latitude |
LATI - Substation latitude in degrees (positive North) |
| ldc |
LDC - DC link inductance in mH (not used by power flow) |
| length |
LEN - Line length |
| line_id |
ID - Multi-section line grouping identifier (2 characters, first must be '&') |
| linx |
LINX - Reactance of dummy series element in pu |
| load_id |
ID - Load identifier (1 or 2 characters) |
| load_records |
Load data records |
| longitude |
LONG - Substation longitude in degrees (positive East) |
| mag1 |
MAG1 - Magnetizing conductance in pu (CM 1, system MVA base) or no-load loss ... |
| mag2 |
MAG2 - Magnetizing susceptance in pu (CM 1, system MVA base) or exciting curr... |
| marg |
MARG - Rectifier margin as per-unit fraction of desired DC power or current (... |
| max_p_output |
PT - Maximum generator active power output in MW |
| max_q_output |
QT - Maximum generator reactive power output in MVAr |
| maxq_1 |
MAXQ - (converter 1) Maximum reactive power limit in MVAr (not used when MODE... |
| maxq_2 |
MAXQ - (converter 2) Maximum reactive power limit in MVAr (not used when MODE... |
| mbase |
MBASE - Machine base power in MW or MVA (unit per BCODE) |
| mdc |
MDC - Control mode (0=blocked, 1=power, 2=current) |
| met |
MET - Metered end (1 or less = IDC, 2 or more = JDC) |
| meter |
METER - Metered end (R=rectifier, I=inverter) |
| metered_end |
MET - Metered end flag |
| min_p_output |
PB - Minimum generator active power output in MW |
| min_q_output |
QB - Minimum generator reactive power output in MVAr |
| minloss_1 |
MINLOSS - (converter 1) Minimum converter loss in kW |
| minloss_2 |
MINLOSS - (converter 2) Minimum converter loss in kW |
| minq_1 |
MINQ - (converter 1) Minimum reactive power limit in MVAr (not used when MODE... |
| minq_2 |
MINQ - (converter 2) Minimum reactive power limit in MVAr (not used when MODE... |
| mname |
MNAME - Name of the master FACTS device when this device is an IPFC slave (MO... |
| mode |
MODE - Control mode |
| mode_1 |
MODE - (converter 1) Converter AC control mode (1=AC voltage control, 2=fixed... |
| mode_2 |
MODE - (converter 2) Converter AC control mode (1=AC voltage control, 2=fixed... |
| model |
MODEL - BOSL model root name ( |
| modsw |
MODSW - Control mode (0 locked, 1 discrete local or remote voltage, 2 continu... |
| multi_section_line_records |
Multi-section line grouping data records |
| multi_terminal_converter_records |
Multi-terminal DC converter records |
| multi_terminal_dc_bus_records |
Multi-terminal DC bus records |
| multi_terminal_dc_link_records |
Multi-terminal DC link records |
| multi_terminal_dc_records |
Multi-terminal DC transmission line data records |
| n |
N - Number of bridges in series |
| n1 |
N1 - Number of steps for block 1 (0 to 9) |
| n2 |
N2 - Number of steps for block 2 (0 to 9) |
| n3 |
N3 - Number of steps for block 3 (0 to 9) |
| n4 |
N4 - Number of steps for block 4 (0 to 9) |
| n5 |
N5 - Number of steps for block 5 (0 to 9) |
| n6 |
N6 - Number of steps for block 6 (0 to 9) |
| n7 |
N7 - Number of steps for block 7 (0 to 9) |
| n8 |
N8 - Number of steps for block 8 (0 to 9) |
| name |
NAME - Bus name (12 characters max) |
| nbi |
NBI - Number of bridges in series (inverter) |
| nbr |
NBR - Number of bridges in series (rectifier) |
| nchar |
NCHAR - Number of two-character identifier values |
| nconv |
NCONV - Number of AC converter station buses |
| ndcbs |
NDCBS - Number of DC buses |
| ndcln |
NDCLN - Number of DC links |
| ndi |
NDI - Node number of bus ICI (0 if ICI is not in a substation) |
| ndr |
NDR - Node number of bus ICR (0 if ICR is not in a substation) |
| new_case_flag |
IC - Change code (0=base case, other=adding/changing data) |
| newton |
NEWTON record |
| nintg |
NINTG - Number of bus data values |
| nmetr |
NMETR - Non-metered end code (1, 2, or 3; the winding whose bus is not metere... |
| nod1 |
NOD1 - Winding 1 node number |
| nod2 |
NOD2 - Winding 2 node number |
| nod3 |
NOD3 - Winding 3 node number |
| node_number |
NI - Node number (1 through 999) |
| nomv1 |
NOMV1 - Winding 1 nominal voltage in kV |
| nomv2 |
NOMV2 - Winding 2 nominal voltage in kV |
| nomv3 |
NOMV3 - Winding 3 nominal voltage in kV |
| normal_status |
NSTAT - Normal device status (1 closed, 0 open) |
| normal_voltage_magnitude_high_limit |
NVHI - Normal voltage magnitude high limit in pu |
| normal_voltage_magnitude_low_limit |
NVLO - Normal voltage magnitude low limit in pu |
| nreal |
NREAL - Number of real data values |
| nreg |
NREG - Node number of IREG bus section to regulate (0 if IREG is not in a sub... |
| nreg_1 |
NREG - (converter 1) Node number of bus VSREG (0 if VSREG is not in a substat... |
| nreg_2 |
NREG - (converter 2) Node number of bus VSREG (0 if VSREG is not in a substat... |
| nstat |
NSTAT - Normal switch status |
| nterm |
NTERM - Number of terminal buses (1 or 2) |
| ntp1 |
NTP1 - Winding 1 number of tap positions |
| ntp2 |
NTP2 - Winding 2 number of tap positions |
| ntp3 |
NTP3 - Winding 3 number of tap positions |
| o1 |
O1 - Owner 1 number |
| o2 |
O2 - Owner 2 number |
| o3 |
O3 - Owner 3 number |
| o4 |
O4 - Owner 4 number |
| owner |
OWNER - Owner number |
| owner_name |
OWNAME - Owner name (12 characters) |
| owner_number |
I - Owner number |
| owner_records |
Owner data records |
| p_output |
PG - Generator active power output in MW |
| pcode |
PC - Scheduled power code (1 mechanical MW output, 2 electrical MW drawn) |
| pdes |
PDES - Desired net interchange (export) in MW |
| points |
The table's points (T, Re(F), Im(F)), up to 99, in file order |
| power_transfer |
PTRAN - MW comprising this transfer (positive = ARFROM selling to ARTO) |
| pset |
PSET - Scheduled active power in MW at 1 |
| ptol |
PTOL - Interchange tolerance in MW |
| pwf_1 |
PWF - (converter 1) Power weighting factor (0 to 1) splitting the reduction b... |
| pwf_2 |
PWF - (converter 2) Power weighting factor (0 to 1) splitting the reduction b... |
| q_output |
QG - Generator reactive power output in MVAr |
| qdes |
QDES - Desired reactive power flow in MVAr |
| r |
R - Branch resistance in pu |
| r1 |
R1 - First rotor cage resistance in pu on MBASE and RATEKV |
| r1_2 |
R1-2 - Winding 1-2 resistance in pu (CZ 1 system base, CZ 2 SBASE1-2) or load... |
| r2 |
R2 - Second rotor cage resistance in pu on MBASE and RATEKV |
| r2_3 |
R2-3 - Winding 2-3 resistance in pu (CZ 1 system base, CZ 2 SBASE2-3) or load... |
| r3_1 |
R3-1 - Winding 3-1 resistance in pu (CZ 1 system base, CZ 2 SBASE3-1) or load... |
| ra |
RA - Armature resistance in pu on MBASE and RATEKV |
| rate1 |
RATE1 - First rating in MVA (or current expressed as MVA) |
| rate1_1 |
RATE1-1 - Winding 1 rating 1 in MVA (or current as MVA, per XFRRAT) |
| rate1_10 |
RATE1-10 - Winding 1 rating 10 in MVA (or current as MVA, per XFRRAT) |
| rate1_11 |
RATE1-11 - Winding 1 rating 11 in MVA (or current as MVA, per XFRRAT) |
| rate1_12 |
RATE1-12 - Winding 1 rating 12 in MVA (or current as MVA, per XFRRAT) |
| rate1_2 |
RATE1-2 - Winding 1 rating 2 in MVA (or current as MVA, per XFRRAT) |
| rate1_3 |
RATE1-3 - Winding 1 rating 3 in MVA (or current as MVA, per XFRRAT) |
| rate1_4 |
RATE1-4 - Winding 1 rating 4 in MVA (or current as MVA, per XFRRAT) |
| rate1_5 |
RATE1-5 - Winding 1 rating 5 in MVA (or current as MVA, per XFRRAT) |
| rate1_6 |
RATE1-6 - Winding 1 rating 6 in MVA (or current as MVA, per XFRRAT) |
| rate1_7 |
RATE1-7 - Winding 1 rating 7 in MVA (or current as MVA, per XFRRAT) |
| rate1_8 |
RATE1-8 - Winding 1 rating 8 in MVA (or current as MVA, per XFRRAT) |
| rate1_9 |
RATE1-9 - Winding 1 rating 9 in MVA (or current as MVA, per XFRRAT) |
| rate2 |
RATE2 - Second rating in MVA (or current expressed as MVA) |
| rate2_1 |
RATE2-1 - Winding 2 rating 1 in MVA (or current as MVA, per XFRRAT) |
| rate2_10 |
RATE2-10 - Winding 2 rating 10 in MVA (or current as MVA, per XFRRAT) |
| rate2_11 |
RATE2-11 - Winding 2 rating 11 in MVA (or current as MVA, per XFRRAT) |
| rate2_12 |
RATE2-12 - Winding 2 rating 12 in MVA (or current as MVA, per XFRRAT) |
| rate2_2 |
RATE2-2 - Winding 2 rating 2 in MVA (or current as MVA, per XFRRAT) |
| rate2_3 |
RATE2-3 - Winding 2 rating 3 in MVA (or current as MVA, per XFRRAT) |
| rate2_4 |
RATE2-4 - Winding 2 rating 4 in MVA (or current as MVA, per XFRRAT) |
| rate2_5 |
RATE2-5 - Winding 2 rating 5 in MVA (or current as MVA, per XFRRAT) |
| rate2_6 |
RATE2-6 - Winding 2 rating 6 in MVA (or current as MVA, per XFRRAT) |
| rate2_7 |
RATE2-7 - Winding 2 rating 7 in MVA (or current as MVA, per XFRRAT) |
| rate2_8 |
RATE2-8 - Winding 2 rating 8 in MVA (or current as MVA, per XFRRAT) |
| rate2_9 |
RATE2-9 - Winding 2 rating 9 in MVA (or current as MVA, per XFRRAT) |
| rate3 |
RATE3 - Third rating in MVA (or current expressed as MVA) |
| rate3_1 |
RATE3-1 - Winding 3 rating 1 in MVA (or current as MVA, per XFRRAT) |
| rate3_10 |
RATE3-10 - Winding 3 rating 10 in MVA (or current as MVA, per XFRRAT) |
| rate3_11 |
RATE3-11 - Winding 3 rating 11 in MVA (or current as MVA, per XFRRAT) |
| rate3_12 |
RATE3-12 - Winding 3 rating 12 in MVA (or current as MVA, per XFRRAT) |
| rate3_2 |
RATE3-2 - Winding 3 rating 2 in MVA (or current as MVA, per XFRRAT) |
| rate3_3 |
RATE3-3 - Winding 3 rating 3 in MVA (or current as MVA, per XFRRAT) |
| rate3_4 |
RATE3-4 - Winding 3 rating 4 in MVA (or current as MVA, per XFRRAT) |
| rate3_5 |
RATE3-5 - Winding 3 rating 5 in MVA (or current as MVA, per XFRRAT) |
| rate3_6 |
RATE3-6 - Winding 3 rating 6 in MVA (or current as MVA, per XFRRAT) |
| rate3_7 |
RATE3-7 - Winding 3 rating 7 in MVA (or current as MVA, per XFRRAT) |
| rate3_8 |
RATE3-8 - Winding 3 rating 8 in MVA (or current as MVA, per XFRRAT) |
| rate3_9 |
RATE3-9 - Winding 3 rating 9 in MVA (or current as MVA, per XFRRAT) |
| rated_mva |
MBASE - Generator MVA base |
| ratekv |
RATEKV - Machine rated voltage in kV line-to-line (0 uses the base voltage of... |
| rating_description |
RATING set description (32 characters) |
| rating_name |
RATING set name (6 characters, used as a report column heading) |
| rating_set_number |
RATING set number (1-12) |
| ratings |
RATING records (up to 12) |
| rc |
RC - Commutating resistance per bridge in ohms |
| rci |
RCI - Inverter commutating transformer resistance per bridge in ohms |
| rcomp |
RCOMP - Compounding resistance in ohms |
| rcr |
RCR - Rectifier commutating transformer resistance per bridge in ohms |
| rdc |
RDC - DC line resistance in ohms |
| reactance |
X - Device reactance in pu (must be non-zero) |
| real_data |
REAL1 |
| regulated_bus_number |
IREG - Regulated bus number |
| regulated_voltage_setpoint |
VS - Regulated voltage setpoint in pu |
| remot |
FCREG - Bus number or extended bus name of the bus whose voltage the shunt re... |
| revision |
REV - raw revision number (34 for v34) |
| rgrnd |
RGRND - Resistance to ground at this DC bus in ohms |
| rma1 |
RMA1 - Winding 1 upper limit (pu or kV per CW, or degrees for |
| rma2 |
RMA2 - Winding 2 upper limit (pu or kV per CW, or degrees for |
| rma3 |
RMA3 - Winding 3 upper limit (pu or kV per CW, or degrees for |
| rmi1 |
RMI1 - Winding 1 lower limit (pu or kV per CW, or degrees for |
| rmi2 |
RMI2 - Winding 2 lower limit (pu or kV per CW, or degrees for |
| rmi3 |
RMI3 - Winding 3 lower limit (pu or kV per CW, or degrees for |
| rmidnt |
RMIDNT - Name of the VSC dc line (MODSW 4) or FACTS device (MODSW 6) |
| rmpct |
RMPCT - Percent of Mvar required to hold voltage at IREG |
| rmpct_1 |
RMPCT - (converter 1) Percent of the total Mvar at the regulated bus supplied... |
| rmpct_2 |
RMPCT - (converter 2) Percent of the total Mvar at the regulated bus supplied... |
| rt |
RT - Step-up transformer resistance in pu |
| sbase1_2 |
SBASE1-2 - Winding 1-2 base MVA |
| sbase2_3 |
SBASE2-3 - Winding 2-3 base MVA (3-winding only) |
| sbase3_1 |
SBASE3-1 - Winding 3-1 base MVA (3-winding only) |
| scale |
SCALE - Load scaling flag |
| scode |
SC - Machine standard code (1 NEMA, 2 IEC) |
| se1 |
SE1 - Saturation factor at terminal voltage E1 |
| se2 |
SE2 - Saturation factor at terminal voltage E2 |
| set1 |
SET1 - Series setpoint 1 (R for MODE 3; magnitude or Vd for MODE 4, 7, 8) |
| set2 |
SET2 - Series setpoint 2 (X for MODE 3; angle or Vq for MODE 4, 7, 8) |
| setvl |
SETVL - Current (A) or power (MW) demand |
| shmx |
SHMX - Maximum shunt current in MVA at unity voltage |
| shunt_id |
ID - Shunt identifier (1 or 2 characters) |
| smax_1 |
SMAX - (converter 1) Converter MVA rating in MVA (0 = unlimited) |
| smax_2 |
SMAX - (converter 2) Converter MVA rating in MVA (0 = unlimited) |
| solver |
SOLVER record |
| station_switching_device_records |
Station switching device records |
| status |
STAT - Load status (0=out of service, 1=in service) |
| stpi |
STPI - Inverter tap step (must be positive) |
| stpr |
STPR - Rectifier tap step (must be positive) |
| stype |
STYPE - Switch type |
| substation_node_records |
Substation node records |
| substation_number |
IS - Substation number (1 through 99999) |
| substation_records |
Substation data records (node-breaker blocks) |
| switch_records |
Switch data records |
| switched_shunt_records |
Switched shunt data records |
| swreg |
SWREG - Bus number or extended bus name of the regulated bus (0 or own bus fo... |
| system_base_frequency |
BASFRQ - System base frequency in Hz |
| system_base_mva |
SBASE - System base MVA |
| t |
Ti - Off-nominal turns ratio (pu) or phase shift angle (deg) |
| tab1 |
TAB1 - Winding 1 tap position table number |
| tab2 |
TAB2 - Winding 2 tap position table number |
| tab3 |
TAB3 - Winding 3 tap position table number |
| table_number |
I - Impedance correction table number |
| tap |
TAP - Tap setting |
| tapi |
TAPI - Inverter tap setting |
| tapr |
TAPR - Rectifier tap setting |
| tcode |
TC - Mechanical load torque model (1 power law, 2 WECC) |
| terminal_type |
TYP - Equipment form code (L load, F fixed shunt, M machine, B or 2 branch or... |
| titles |
Title lines (up to 2 lines) |
| tmni |
TMNI - Inverter minimum tap setting |
| tmnr |
TMNR - Rectifier minimum tap setting |
| tmxi |
TMXI - Inverter maximum tap setting |
| tmxr |
TMXR - Rectifier maximum tap setting |
| to_area |
ARTO - To area number |
| to_bus_number |
J - To bus number |
| to_node |
NJ - To node number (1 through 999), must be in the substation |
| tpmn |
TPMN - Minimum tap setting |
| tpmx |
TPMX - Maximum tap setting |
| tr |
TR - Actual transformer ratio (pu) |
| transfer_id |
TRID - Single-character interarea transfer identifier (0-9 or A-Z) |
| transformer_ratings_units |
XFRRAT - Transformer ratings units flag |
| transformer_records |
Transformer data records |
| tri |
TRI - Inverter transformer ratio (pu) |
| trmx |
TRMX - Maximum bridge active power transfer in MW |
| trr |
TRR - Rectifier transformer ratio (pu) |
| tstp |
TSTP - Tap step (must be positive) |
| two_terminal_dc_records |
Two-terminal DC transmission line data records |
| tysl |
TYSL record |
| va |
VA - Node voltage phase angle in degrees |
| vcmod |
VCMOD - Mode switch DC voltage in kV |
| vconv |
VCONV - Bus number of the converter controlling DC voltage on the positive po... |
| vconvn |
VCONVN - Bus number of the converter controlling DC voltage on the negative p... |
| vecgrp |
VECGRP - Vector group (12 characters) |
| vm |
VM - Node voltage magnitude in pu |
| vma1 |
VMA1 - Winding 1 upper limit (pu bus voltage, Mvar or MW per |
| vma2 |
VMA2 - Winding 2 upper limit (pu bus voltage, Mvar or MW per |
| vma3 |
VMA3 - Winding 3 upper limit (pu bus voltage, Mvar or MW per |
| vmi1 |
VMI1 - Winding 1 lower limit (pu bus voltage, Mvar or MW per |
| vmi2 |
VMI2 - Winding 2 lower limit (pu bus voltage, Mvar or MW per |
| vmi3 |
VMI3 - Winding 3 lower limit (pu bus voltage, Mvar or MW per |
| vmstar |
VMSTAR - Star point voltage magnitude in pu |
| voltage_angle |
VA - Voltage angle in degrees |
| voltage_magnitude |
VM - Voltage magnitude in pu |
| vsc_dc_records |
VSC DC transmission line data records |
| vschd |
VSCHD - Scheduled compounded DC voltage in kV |
| vset |
VSET - Voltage setpoint in pu |
| vsmx |
VSMX - Maximum series voltage in pu |
| vsref |
VSREF - Series voltage reference code (0 sending end voltage, 1 series curren... |
| vsreg_1 |
VSREG - (converter 1) Bus number whose voltage is regulated by this converter... |
| vsreg_2 |
VSREG - (converter 2) Bus number whose voltage is regulated by this converter... |
| vswhi |
VSWHI - Voltage upper limit for switching in per-unit |
| vswlo |
VSWLO - Voltage lower limit for switching in per-unit |
| vtmn |
VTMN - Minimum voltage limit at the terminal end bus in pu |
| vtmx |
VTMX - Maximum voltage limit at the terminal end bus in pu |
| windv1 |
WINDV1 - Winding 1 turns ratio in pu (CW 1 or 3) or voltage in kV (CW 2) |
| windv2 |
WINDV2 - Winding 2 turns ratio in pu (CW 1 or 3) or voltage in kV (CW 2) |
| windv3 |
WINDV3 - Winding 3 turns ratio in pu (CW 1 or 3) or voltage in kV (CW 2) |
| wmod |
WMOD - Wind machine control mode |
| wpf |
WPF - Wind machine power factor |
| x |
X - Branch reactance in pu |
| x1 |
X1 - First rotor cage reactance in pu on MBASE and RATEKV |
| x1_2 |
X1-2 - Winding 1-2 reactance in pu (CZ 1 system base, CZ 2 SBASE1-2) or imped... |
| x2 |
X2 - Second rotor cage reactance in pu on MBASE and RATEKV |
| x2_3 |
X2-3 - Winding 2-3 reactance in pu (CZ 1 system base, CZ 2 SBASE2-3) or imped... |
| x3 |
X3 - Third rotor reactance in pu on MBASE and RATEKV |
| x3_1 |
X3-1 - Winding 3-1 reactance in pu (CZ 1 system base, CZ 2 SBASE3-1) or imped... |
| xa |
XA - Armature leakage reactance in pu on MBASE and RATEKV |
| xamult |
XAMULT - Multiplier for the saturated XA (0 to 1 |
| xc |
XC - Commutating reactance per bridge in ohms |
| xcapi |
XCAPI - Inverter commutating capacitor reactance per bridge in ohms |
| xcapr |
XCAPR - Rectifier commutating capacitor reactance per bridge in ohms |
| xci |
XCI - Inverter commutating transformer reactance per bridge in ohms |
| xcr |
XCR - Rectifier commutating transformer reactance per bridge in ohms |
| xm |
XM - Unsaturated magnetizing reactance in pu on MBASE and RATEKV |
| xt |
XT - Step-up transformer reactance in pu |
| zcod |
ZCOD - Impedance correction method (0 winding impedances, 1 bus-to-bus impeda... |
| zone |
ZONE - Zone number |
| zone_name |
ZONAME - Zone name (12 characters) |
| zone_number |
I - Zone number |
| zone_records |
Zone data records |
| zr |
ZR - Complex machine impedance ZSORCE, resistance component in pu |
| zx |
ZX - Complex machine impedance ZSORCE, reactance component in pu |