Skip to content

Class: InductionMachineRecord

Induction machine data record

URI: raw:InductionMachineRecord

 classDiagram
    class InductionMachineRecord
    click InductionMachineRecord href "../InductionMachineRecord/"
      InductionMachineRecord : a

      InductionMachineRecord : area

      InductionMachineRecord : b

      InductionMachineRecord : bcode

      InductionMachineRecord : bus_id

      InductionMachineRecord : d

      InductionMachineRecord : dcode

      InductionMachineRecord : e

      InductionMachineRecord : e1

      InductionMachineRecord : e2

      InductionMachineRecord : h

      InductionMachineRecord : ia1

      InductionMachineRecord : ia2

      InductionMachineRecord : mbase

      InductionMachineRecord : name

      InductionMachineRecord : owner

      InductionMachineRecord : pcode

      InductionMachineRecord : pset

      InductionMachineRecord : r1

      InductionMachineRecord : r2

      InductionMachineRecord : ra

      InductionMachineRecord : ratekv

      InductionMachineRecord : scode

      InductionMachineRecord : se1

      InductionMachineRecord : se2

      InductionMachineRecord : status

      InductionMachineRecord : tcode

      InductionMachineRecord : x1

      InductionMachineRecord : x2

      InductionMachineRecord : x3

      InductionMachineRecord : xa

      InductionMachineRecord : xamult

      InductionMachineRecord : xm

      InductionMachineRecord : zone

Slots

Name Cardinality and Range Description Inheritance
bus_id 1
Integer
I - Bus number or extended bus name direct
name 0..1
String
ID - Machine identifier (one or two characters) direct
status 0..1
Integer
ST - Machine status (1 in-service, 0 out-of-service) direct
scode 0..1
Integer
SC - Machine standard code (1 NEMA, 2 IEC) direct
dcode 0..1
Integer
DC - Machine design code (0 custom, 1-5 NEMA or IEC design) direct
area 0..1
Integer
AREA - Area number (1 through 9999) direct
zone 0..1
Integer
ZONE - Zone number (1 through 9999) direct
owner 0..1
Integer
OWNER - Owner number (1 through 9999) direct
tcode 0..1
Integer
TC - Mechanical load torque model (1 power law, 2 WECC) direct
bcode 0..1
Integer
BC - Machine base power code (1 mechanical MW, 2 electrical MVA) direct
mbase 0..1
Float
MBASE - Machine base power in MW or MVA (unit per BCODE) direct
ratekv 0..1
Float
RATEKV - Machine rated voltage in kV line-to-line (0 uses the base voltage of... direct
pcode 0..1
Integer
PC - Scheduled power code (1 mechanical MW output, 2 electrical MW drawn) direct
pset 0..1
Float
PSET - Scheduled active power in MW at 1 direct
h 0..1
Float
H - Machine inertia in pu on MBASE direct
a 0..1
Float
A - Load torque coefficient A (WECC model only) direct
b 0..1
Float
B - Load torque coefficient B (WECC model only) direct
d 0..1
Float
D - Load torque coefficient D (power law exponent term, or WECC) direct
e 0..1
Float
E - Load torque coefficient E (WECC model only) direct
ra 0..1
Float
RA - Armature resistance in pu on MBASE and RATEKV direct
xa 0..1
Float
XA - Armature leakage reactance in pu on MBASE and RATEKV direct
xm 0..1
Float
XM - Unsaturated magnetizing reactance in pu on MBASE and RATEKV direct
r1 0..1
Float
R1 - First rotor cage resistance in pu on MBASE and RATEKV direct
x1 0..1
Float
X1 - First rotor cage reactance in pu on MBASE and RATEKV direct
r2 0..1
Float
R2 - Second rotor cage resistance in pu on MBASE and RATEKV direct
x2 0..1
Float
X2 - Second rotor cage reactance in pu on MBASE and RATEKV direct
x3 0..1
Float
X3 - Third rotor reactance in pu on MBASE and RATEKV direct
e1 0..1
Float
E1 - First terminal voltage point on the saturation curve in pu on RATEKV direct
se1 0..1
Float
SE1 - Saturation factor at terminal voltage E1 direct
e2 0..1
Float
E2 - Second terminal voltage point on the saturation curve in pu on RATEKV direct
se2 0..1
Float
SE2 - Saturation factor at terminal voltage E2 direct
ia1 0..1
Float
IA1 - First stator current in pu for stator leakage saturation direct
ia2 0..1
Float
IA2 - Second stator current in pu for stator leakage saturation direct
xamult 0..1
Float
XAMULT - Multiplier for the saturated XA (0 to 1 direct

Usages

used by used in type used
RawModel induction_machine_records range InductionMachineRecord

Identifier and Mapping Information

Schema Source

  • from schema: https://gridappsd.org/cimhub/raw_v34

Mappings

Mapping Type Mapped Value
self raw:InductionMachineRecord
native raw:InductionMachineRecord

LinkML Source

Direct

name: InductionMachineRecord
description: Induction machine data record
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
  bus_id:
    name: bus_id
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: int
    description: I - Bus number or extended bus name
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: integer
    required: true
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      width:
        tag: width
        value: 2
      quote:
        tag: quote
        value: true
      quote_char:
        tag: quote_char
        value: ''''
      raw_default:
        tag: raw_default
        value: '1'
    description: ID - Machine identifier (one or two characters)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    domain_of:
    - BusRecord
    - BranchRecord
    - SwitchRecord
    - TransformerRecord
    - AreaInterchangeRecord
    - TwoTerminalDCRecord
    - VscDcRecord
    - MultiTerminalDCRecord
    - FactsDeviceRecord
    - GneDeviceRecord
    - InductionMachineRecord
    - SubstationRecord
    - SubstationNodeRecord
    - StationSwitchingDeviceRecord
    range: string
    required: false
  status:
    name: status
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: ST - Machine status (1 in-service, 0 out-of-service)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    domain_of:
    - LoadRecord
    - FixedShuntRecord
    - GeneratorRecord
    - BranchRecord
    - SwitchRecord
    - TransformerRecord
    - SwitchedShuntRecord
    - GneDeviceRecord
    - InductionMachineRecord
    - SubstationNodeRecord
    - StationSwitchingDeviceRecord
    range: integer
    required: false
  scode:
    name: scode
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: SC - Machine standard code (1 NEMA, 2 IEC)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  dcode:
    name: dcode
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 2
    description: DC - Machine design code (0 custom, 1-5 NEMA or IEC design)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  area:
    name: area
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: int
      raw_default_rule:
        tag: raw_default_rule
        value: area of bus I
    description: AREA - Area number (1 through 9999)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    domain_of:
    - BusRecord
    - LoadRecord
    - MultiTerminalDCBusRecord
    - InductionMachineRecord
    range: integer
    required: false
  zone:
    name: zone
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: int
      raw_default_rule:
        tag: raw_default_rule
        value: zone of bus I
    description: ZONE - Zone number (1 through 9999)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    domain_of:
    - BusRecord
    - LoadRecord
    - MultiTerminalDCBusRecord
    - InductionMachineRecord
    range: integer
    required: false
  owner:
    name: owner
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: int
      raw_default_rule:
        tag: raw_default_rule
        value: owner of bus I
    description: OWNER - Owner number (1 through 9999)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    domain_of:
    - BusRecord
    - LoadRecord
    - MultiTerminalDCBusRecord
    - FactsDeviceRecord
    - GneDeviceRecord
    - InductionMachineRecord
    range: integer
    required: false
  tcode:
    name: tcode
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: TC - Mechanical load torque model (1 power law, 2 WECC)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  bcode:
    name: bcode
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: BC - Machine base power code (1 mechanical MW, 2 electrical MVA)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  mbase:
    name: mbase
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default_rule:
        tag: raw_default_rule
        value: system base MVA
    description: MBASE - Machine base power in MW or MVA (unit per BCODE)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  ratekv:
    name: ratekv
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: RATEKV - Machine rated voltage in kV line-to-line (0 uses the base
      voltage of bus I)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
    unit:
      ucum_code: kV
  pcode:
    name: pcode
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: PC - Scheduled power code (1 mechanical MW output, 2 electrical MW
      drawn)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  pset:
    name: pset
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: PSET - Scheduled active power in MW at 1.0 pu terminal voltage (positive
      means motoring)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
    unit:
      ucum_code: MW
  h:
    name: h
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: H - Machine inertia in pu on MBASE
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  a:
    name: a
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: A - Load torque coefficient A (WECC model only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  b:
    name: b
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: B - Load torque coefficient B (WECC model only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    domain_of:
    - BranchRecord
    - InductionMachineRecord
    range: float
    required: false
  d:
    name: d
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: D - Load torque coefficient D (power law exponent term, or WECC)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  e:
    name: e
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: E - Load torque coefficient E (WECC model only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  ra:
    name: ra
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: RA - Armature resistance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  xa:
    name: xa
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: XA - Armature leakage reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  xm:
    name: xm
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 2.5
    description: XM - Unsaturated magnetizing reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  r1:
    name: r1
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 999.0
    description: R1 - First rotor cage resistance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  x1:
    name: x1
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 999.0
    description: X1 - First rotor cage reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  r2:
    name: r2
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 999.0
    description: R2 - Second rotor cage resistance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  x2:
    name: x2
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 999.0
    description: X2 - Second rotor cage reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  x3:
    name: x3
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: X3 - Third rotor reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  e1:
    name: e1
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: E1 - First terminal voltage point on the saturation curve in pu on
      RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  se1:
    name: se1
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: SE1 - Saturation factor at terminal voltage E1
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  e2:
    name: e2
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.2
    description: E2 - Second terminal voltage point on the saturation curve in pu
      on RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  se2:
    name: se2
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: SE2 - Saturation factor at terminal voltage E2
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  ia1:
    name: ia1
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: IA1 - First stator current in pu for stator leakage saturation
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  ia2:
    name: ia2
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: IA2 - Second stator current in pu for stator leakage saturation
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  xamult:
    name: xamult
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: XAMULT - Multiplier for the saturated XA (0 to 1.0)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    domain_of:
    - InductionMachineRecord
    range: float
    required: false

Induced

name: InductionMachineRecord
description: Induction machine data record
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
  bus_id:
    name: bus_id
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: int
    description: I - Bus number or extended bus name
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: integer
    required: true
  name:
    name: name
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: string
      width:
        tag: width
        value: 2
      quote:
        tag: quote
        value: true
      quote_char:
        tag: quote_char
        value: ''''
      raw_default:
        tag: raw_default
        value: '1'
    description: ID - Machine identifier (one or two characters)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    owner: InductionMachineRecord
    domain_of:
    - BusRecord
    - BranchRecord
    - SwitchRecord
    - TransformerRecord
    - AreaInterchangeRecord
    - TwoTerminalDCRecord
    - VscDcRecord
    - MultiTerminalDCRecord
    - FactsDeviceRecord
    - GneDeviceRecord
    - InductionMachineRecord
    - SubstationRecord
    - SubstationNodeRecord
    - StationSwitchingDeviceRecord
    range: string
    required: false
  status:
    name: status
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: ST - Machine status (1 in-service, 0 out-of-service)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    owner: InductionMachineRecord
    domain_of:
    - LoadRecord
    - FixedShuntRecord
    - GeneratorRecord
    - BranchRecord
    - SwitchRecord
    - TransformerRecord
    - SwitchedShuntRecord
    - GneDeviceRecord
    - InductionMachineRecord
    - SubstationNodeRecord
    - StationSwitchingDeviceRecord
    range: integer
    required: false
  scode:
    name: scode
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: SC - Machine standard code (1 NEMA, 2 IEC)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  dcode:
    name: dcode
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 2
    description: DC - Machine design code (0 custom, 1-5 NEMA or IEC design)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  area:
    name: area
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: int
      raw_default_rule:
        tag: raw_default_rule
        value: area of bus I
    description: AREA - Area number (1 through 9999)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    owner: InductionMachineRecord
    domain_of:
    - BusRecord
    - LoadRecord
    - MultiTerminalDCBusRecord
    - InductionMachineRecord
    range: integer
    required: false
  zone:
    name: zone
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: int
      raw_default_rule:
        tag: raw_default_rule
        value: zone of bus I
    description: ZONE - Zone number (1 through 9999)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    owner: InductionMachineRecord
    domain_of:
    - BusRecord
    - LoadRecord
    - MultiTerminalDCBusRecord
    - InductionMachineRecord
    range: integer
    required: false
  owner:
    name: owner
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: int
      raw_default_rule:
        tag: raw_default_rule
        value: owner of bus I
    description: OWNER - Owner number (1 through 9999)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    owner: InductionMachineRecord
    domain_of:
    - BusRecord
    - LoadRecord
    - MultiTerminalDCBusRecord
    - FactsDeviceRecord
    - GneDeviceRecord
    - InductionMachineRecord
    range: integer
    required: false
  tcode:
    name: tcode
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: TC - Mechanical load torque model (1 power law, 2 WECC)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  bcode:
    name: bcode
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: BC - Machine base power code (1 mechanical MW, 2 electrical MVA)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  mbase:
    name: mbase
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default_rule:
        tag: raw_default_rule
        value: system base MVA
    description: MBASE - Machine base power in MW or MVA (unit per BCODE)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  ratekv:
    name: ratekv
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: RATEKV - Machine rated voltage in kV line-to-line (0 uses the base
      voltage of bus I)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
    unit:
      ucum_code: kV
  pcode:
    name: pcode
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: PC - Scheduled power code (1 mechanical MW output, 2 electrical MW
      drawn)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: integer
    required: false
  pset:
    name: pset
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: PSET - Scheduled active power in MW at 1.0 pu terminal voltage (positive
      means motoring)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
    unit:
      ucum_code: MW
  h:
    name: h
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: H - Machine inertia in pu on MBASE
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  a:
    name: a
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: A - Load torque coefficient A (WECC model only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  b:
    name: b
    annotations:
      order:
        tag: order
        value: 17
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: B - Load torque coefficient B (WECC model only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    owner: InductionMachineRecord
    domain_of:
    - BranchRecord
    - InductionMachineRecord
    range: float
    required: false
  d:
    name: d
    annotations:
      order:
        tag: order
        value: 18
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: D - Load torque coefficient D (power law exponent term, or WECC)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  e:
    name: e
    annotations:
      order:
        tag: order
        value: 19
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: E - Load torque coefficient E (WECC model only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  ra:
    name: ra
    annotations:
      order:
        tag: order
        value: 20
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: RA - Armature resistance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  xa:
    name: xa
    annotations:
      order:
        tag: order
        value: 21
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: XA - Armature leakage reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  xm:
    name: xm
    annotations:
      order:
        tag: order
        value: 22
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 2.5
    description: XM - Unsaturated magnetizing reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  r1:
    name: r1
    annotations:
      order:
        tag: order
        value: 23
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 999.0
    description: R1 - First rotor cage resistance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  x1:
    name: x1
    annotations:
      order:
        tag: order
        value: 24
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 999.0
    description: X1 - First rotor cage reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  r2:
    name: r2
    annotations:
      order:
        tag: order
        value: 25
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 999.0
    description: R2 - Second rotor cage resistance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  x2:
    name: x2
    annotations:
      order:
        tag: order
        value: 26
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 999.0
    description: X2 - Second rotor cage reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  x3:
    name: x3
    annotations:
      order:
        tag: order
        value: 27
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: X3 - Third rotor reactance in pu on MBASE and RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  e1:
    name: e1
    annotations:
      order:
        tag: order
        value: 28
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: E1 - First terminal voltage point on the saturation curve in pu on
      RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  se1:
    name: se1
    annotations:
      order:
        tag: order
        value: 29
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: SE1 - Saturation factor at terminal voltage E1
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  e2:
    name: e2
    annotations:
      order:
        tag: order
        value: 30
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.2
    description: E2 - Second terminal voltage point on the saturation curve in pu
      on RATEKV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  se2:
    name: se2
    annotations:
      order:
        tag: order
        value: 31
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: SE2 - Saturation factor at terminal voltage E2
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  ia1:
    name: ia1
    annotations:
      order:
        tag: order
        value: 32
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: IA1 - First stator current in pu for stator leakage saturation
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  ia2:
    name: ia2
    annotations:
      order:
        tag: order
        value: 33
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: IA2 - Second stator current in pu for stator leakage saturation
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false
  xamult:
    name: xamult
    annotations:
      order:
        tag: order
        value: 34
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: XAMULT - Multiplier for the saturated XA (0 to 1.0)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/induction_machine
    rank: 1000
    owner: InductionMachineRecord
    domain_of:
    - InductionMachineRecord
    range: float
    required: false