The exporter

The exporter reads a cim18v17 network and returns a GraphModel of RAW records, the same kind of model Raw34Reader.read_all() returns, so Raw34Writer writes it and the reader and importer read it back. It does no file I/O. The code is exporter/cim_to_raw.py and one module per RAW table beside it. The design record, with a slot table per record class, is EXPORT_MAPPING.md.

The entry points

import cimhub_raw.schema.raw_v34.raw34_schema as schema
from cimhub_core.cimtbl_testing import cim_scope
from cimhub_raw.exporter.cim_to_raw import RawExporter, cim_to_raw
from cimhub_raw.importer.raw_to_cimtbl import raw_to_cim
from cimhub_raw.raw34_reader import Raw34Reader
from cimhub_raw.raw34_writer import Raw34Writer

with cim_scope():
    native = Raw34Reader("cimhub_raw/tests/cases/IEEE14/IEEE_14_bus.raw").read_all()
    network = raw_to_cim(native, name="IEEE14")

    exported = RawExporter().to_model(network)                     # a GraphModel, nothing written
    print(sorted(cls.__name__ for cls in exported.graph if exported.count(cls))[:4])
    print(Raw34Writer().serialize(exported.list_by_class(schema.FixedShuntRecord)[0]))   # 9,'1 ',1,0.000,19.000

    cim_to_raw(network, "/tmp/ieee14_export.raw")                  # to_model, then Raw34Writer.write
Call Does
RawExporter().to_model(network) Returns the GraphModel. It has no options: the names and numbers come from the mRIDs the importer wrote.
cim_to_raw(network, destination) RawExporter().to_model(network), then Raw34Writer().write(model, destination).
export_tables(network, modules) The records of the given modules only, each with its composite ID. The tests use it to export one table at a time.
export_context(network) The ExportContext the modules share, for a test or a script.

to_model

to_model does these things, in this order:

  1. _check_exported(network) raises no RAW export yet for {...} (with the class names and counts) for any ConductingEquipment class no module lists in its CIM_CLASSES, so nothing is dropped silently. A DC line's CsConverters and VsConverters raise here.
  2. export_tables(network, EXPORT_ORDER) builds the ExportContext once.
  3. For each module in EXPORT_ORDER, module.export(context) returns RAW records; each gets its composite ID from composite_id.assign_composite_id and is added to a new GraphModel.

EXPORT_ORDER is: case identification, zone, area interchange, bus, branch, switch, multi-section line, load, fixed shunt, switched shunt, generator, transformer, impedance correction, FACTS device. A module may import another's helpers (the transformer module reads the generator module's step_ups, so a machine's step-up is not also written as a transformer), but the order is also the order of the records in the model, and so of the sections in the file.

The module contract

Each module has:

Name Holds
NATIVE_CLASS The RAW record class it writes (schema.FixedShuntRecord).
CIM_CLASSES The ConductingEquipment classes it exports, which _check_exported collects. A table with no equipment of its own (zone, area, multi-section line, impedance correction, case identification) has ().
SLOTS {NATIVE_CLASS: {slot: Slot}}: what the module does with every slot of the record.
export(context) The records, a list sorted by key, over the whole network.

A module works over the whole network, not object by object, because IDs are allocated per bus and a bus's AREA is a trace.

ExportContext

ExportContext is a NamedTuple made once by export_context(network):

Field Holds
network The CIM network. context.objects(*cim_classes) returns its objects of those classes, class by class.
bus_numbers TopologicalNode to its bus number, from busNumber. A node without one is internal to a device (a machine behind its step-up) and is left out, with one info log with the count.
zone_numbers, area_numbers SubGeographicalRegion to its zone number and ControlArea to its area number.
bus_areas TopologicalNode to its ControlArea, or None when the trace cannot reach it.
branch_ratings_in_current NXFRAT: the branch and switch ratings are CurrentLimits.
transformer_ratings_in_current XFRRAT: the transformer ratings are CurrentLimits.

Identity and names: identity.py

identity.py turns the importer's mRIDs back into RAW numbers, IDs and names. The importer's mRID prefix of each table is imported from the importer's module, so the two directions cannot drift.

Function Does
bus_numbers(nodes) Each numbered node's busNumber. A number used twice, or no numbered node at all, raises.
keyed_numbers(objects, prefix) Each object's number from its mRID <prefix><n> (srgn_3, ca_1). An object whose mRID is not of that form gets the next number above the largest taken, in mRID order, with an info log of the count. This is one of the two documented fallbacks. Two mRIDs giving one number raise.
terminal_buses(device, context) The bus number at each of the device's terminals, in sequenceNumber order. A terminal on a node with no number raises.
keyed_ids(devices, width, fallback_prefix="") Each device's ID, for (device, mRID prefix, buses in order): the rest of <prefix><bus>_<bus>_..._<ID> when it fits width, else the next free 1, 2, ... among the devices on the same buses (RAW's key), with an info log. The second documented fallback. Two devices with one key raise.
raw_name(obj, key, width) The NAME: blank when unset or equal to key (the importer's blank-NAME form), else the name; a name longer than width raises.

The area trace: area_trace.py

CIM 18 has no association from a node to a ControlArea, so the importer records an area through what CIM already places in one: generating units and tie flows. trace_areas(network) recovers each bus's AREA the same way:

  • Seeds: the node of every SynchronousMachine and PowerElectronicsConnection, with its unit's ControlArea; a TieFlow pair's terminal, with the pair's positiveFlowIn = false area, and the other terminals of that device, with the pair's true (home) area.
  • The areas spread across every device with two or more nodes and no TieFlow (topology.islands, shared with the importer).
  • Two areas meeting in one island raise. A node in an island with no seed gets None; the importer wrote the AREA on that bus's row as untranscribed, and the exporter writes it blank.

metered_terminal(device) returns the sequenceNumber of the terminal holding a device's TieFlow pair, which is its metered end (MET); pairs on two terminals raise. The importer's untraced_area_buses runs the same rule over the RAW records, so the two stay together.

Ratings: ratings.py

RATE1..RATE12 are the limits whose type has the importer's mRID olt_rate<n>. device_limits returns a device's kind (ApparentPowerLimit, CurrentLimit or none) and its limits by type, through get_limits_by_type; a device holding both kinds raises. device_ratings(device, terminal=None) gives the twelve values, 0 where there is no limit; a current is converted to MVA with rating_from_ka on the device's BaseVoltage (a transformer's, per winding, on that winding's terminal). ratings_in_current(devices, per_terminal=False) decides NXFRAT and XFRRAT for the case: both kinds among the devices raise, because RAW's flag is one or the other.

Reading CIM: only through the core getters

An exporter never reads a CIM attribute for a quantity itself. Every value comes through one of:

  • a cimhub_core.getters function, which resolves units, bases and the CIM shape that holds the concept (a line's impedance, a transformer's windings, a tap changer's steps, a shunt's admittance, a regulating control, a node's solved voltage, a limit set);
  • cimtables.graph_write.get_qty(obj, attribute, unit), which reads one attribute in the unit asked for (get_qty(area, "pTolerance", "MW")).

The unit is always asked for, never converted by hand. A RAW per unit value is then a named inverse from importer/cimtbl/derived.py (per_unit_from_kv, mva_from_per_unit, rating_from_ka), so a formula is stated once. exporter/shunt_admittance.py wraps get_shunt_admittance so that a shunt's g and b come out in pu on its bus's base, which is how RAW states every shunt; a shunt rated off its bus voltage raises. The getters are described in core's getter guide and reference; a missing getter is a request to the core owner, not a local reimplementation.

SLOTS

SLOTS is the exporter's mirror of the importer's FIELDS: every slot of the RAW record, with what the module does with it. A cimhub_core.export_slots.Slot(kind, note) has one of four kinds:

Kind Meaning
written The value comes from a getter.
rule A fixed or computed value RAW needs (IC 0, REV 34, ST from inService, IDE from the machines).
unset CIM cannot hold it. The slot is None and written blank, so PSS/E applies its default. Everything the importer marks untranscribed is unset here, unless the spec recovers it (the bus AREA).
not mapped A form of the same data that is not written.

check_slots(SLOTS[NATIVE_CLASS], NATIVE_CLASS) raises when a slot of the record is missing from the dict, or a key is not a slot, or a kind is unknown. test_slots_are_complete runs it for every module in EXPORT_ORDER, and test_untranscribed_on_import_is_unset_on_export checks the importer's untranscribed fields against the exporter's unset slots.

The slot tables in EXPORT_MAPPING.md (### Slots (generated from SLOTS)) are the output of slots_table(slots, "RAW") from cimhub_core.export_slots. No test or script in this package regenerates them, so when a note in SLOTS changes, render the table and update the spec by hand.

One module end to end: fixed_shunt

fixed_shunt.py writes a LinearShuntCompensator with no control as a Fixed shunt. A shunt with a RegulatingControl is a switched-shunt block, and a branch's line shunt is that branch's GI, BI, GJ and BJ, so the module has to tell them apart.

from cimhub_raw.exporter import fixed_shunt

for slot, how in fixed_shunt.SLOTS[fixed_shunt.NATIVE_CLASS].items():
    print(slot, how.kind, "-", how.note)

export(context):

  1. branch.line_shunts(context) returns the shunts that belong to a branch: those whose mRID is cap_<key>_i or _j for a branch ln_<key> or sc_<key> and that sit on that end's bus. They are left out here.
  2. The remaining shunts with no RegulatingControl are collected with terminal_buses(shunt, context).
  3. keyed_ids(..., ID_WIDTH) gives each its ID: the rest of cap_<bus>_<ID>, else the next free one on the bus.
  4. For each, bus_base_admittance(shunt, "actual", base_power) gives g and b in pu on the bus's base, and mva_from_per_unit(g, base_mva) makes them GL (MW) and BL (Mvar) at one per unit voltage. STATUS is 0 when get_in_service(shunt, which="actual") is false, else 1.
  5. The records are sorted by (bus_number, shunt_id).

The round trip checks it: test_round_trip reads each fixture, imports it, exports it and compares every slot not marked unset of every module with the original, so GL and BL come back as they went in.

Adding an exporter module

  1. Spec first. Add a section to EXPORT_MAPPING.md: which CIM classes become the record, which getter gives each slot, the keys and names, the fail-fast rules and the expected differences from the original case.
  2. The module. Create exporter/<table>.py with NATIVE_CLASS, CIM_CLASSES, SLOTS and export(context). List every slot of the record in SLOTS (cimhub_core.export_slots.with_default fills the rest with one kind). Read through the getters and get_qty, take the importer's prefix and derived functions rather than restating them, and use keyed_ids and terminal_buses for IDs and buses. Raise on what RAW cannot hold; never write a guessed value.
  3. The order. Add the module to EXPORT_ORDER in cim_to_raw.py, after any module it imports helpers from. Its CIM_CLASSES stop _check_exported from raising for that equipment.
  4. The tests. In tests/test_cim_to_raw.py: add the module to the chain of E<n>_MODULES tuples that ends in LANDED (so test_round_trip and test_written_case_reads_back cover it), and a test for each fail-fast rule with pytest.raises(ValueError, match=...). Differences that are expected by design go in EXPECTED, with the reason. Add the module and its importer to the parameters of test_untranscribed_on_import_is_unset_on_export; a slot that is written although the importer lists the field untranscribed goes in NOT_UNSET.
  5. The slot table. Render slots_table(SLOTS[NATIVE_CLASS], "RAW") into the spec's ### Slots section.
  6. Run scripts/test-all.sh raw and scripts/leak-gate.sh.