Export: CIM to RAW

from cimhub_raw.exporter.cim_to_raw import RawExporter, cim_to_raw
from cimhub_raw.raw34_writer import Raw34Writer

cim_to_raw(network, "IEEE14_from_cim.raw")           # export and write in one call

model = RawExporter().to_model(network)              # records only, no files
Raw34Writer().write(model, "IEEE14_from_cim.raw")

network is a cim18v17 network that carries the bus numbers the importer wrote, for example the result of raw_to_cim. The exporter reads it through the getters in cimhub_core and returns a GraphModel of RAW records, the same shape Raw34Reader.read_all() returns, so the .raw the writer produces reads back through the reader and the importer. Only Raw34Writer touches the filesystem, and it does not create folders: the destination's folder must exist.

Options

RawExporter().to_model(network) and cim_to_raw(network, destination) take no options. destination is the .raw path. The case's units come from the network: the exporter reads whether the ratings are in MVA or in current (below), and every quantity in the unit RAW fixes for it.

What it exports

Each RAW table is written from the CIM classes it was imported to. Records come out keyed as they went in.

RAW table Read from CIM
case identification BasePower (SBASE), BaseFrequency (BASFRQ), the rating-set OperationalLimitTypes (RATING records), NXFRAT and XFRRAT from the kind of limit the ratings are
zone SubGeographicalRegion
area ControlArea (PDES is minus netInterchange, PTOL is pTolerance)
bus TopologicalNode with its BusbarSection (voltage limits) and SvVoltage (VM and VA)
branch ACLineSegment, SeriesCompensator, and the line shunts linked to them
system switching device Switch, Breaker and Disconnector between two buses
multi-section line the Line that holds a path of branches
load EnergyConsumer, ConformLoad, NonConformLoad
fixed shunt, switched shunt LinearShuntCompensator (a bank's blocks under one RegulatingControl are one switched shunt); StaticVarCompensator, a MODSW 2 switched shunt
generator SynchronousMachine, PowerElectronicsConnection, and a generator's step-up transformer, folded back into GTAP, RT and XT
transformer PowerTransformer that is not a generator's step-up
FACTS device StaticSynchronousCompensator, shunt only (J = 0)
impedance correction ImpedanceTapChangerTable

A value that is not in CIM is left blank, and RAW applies its own default (the owner fields, for example, and the case's title lines). The round trip page lists what comes back different.

Bus numbers and IDs

RAW identifies things by number and by short IDs. The exporter takes them from the mRIDs the importer wrote:

  • Bus number (I) is TopologicalNode.busNumber. A node without one is internal to a device (a generator's step-up node, a DC converter's valve side) and is not a bus. A number used by two nodes raises, and so does a network where no node has one: no TopologicalNode has a busNumber: numbering a model from another format is not done yet. A network from another converter does not export until it carries bus numbers.
  • Zone and area numbers come from the mRIDs srgn_<n> and ca_<n>. A zone or area whose mRID is not of that form gets the next number above the largest taken, and the exporter logs the count at INFO. Two mRIDs that give one number raise.
  • A device's ID (CKT of a branch, switch and transformer, the load, shunt and generator ID) is the rest of its mRID after the prefix and its buses: ln_4_7_1 is the branch 4 to 7 with CKT 1. It is used only when the buses are the device's own, in order, and it fits RAW's two characters. Otherwise the ID is the next free 1, 2, ... on those buses, and the exporter logs the count at INFO. A multi-section line without a key gets &1, &2, ... Two devices with one key raise.
  • NAME is the CIM name (for a bus, the TopologicalNode's busName when set, as a topology processor writes it). It is written blank when it is the key the importer uses for a blank NAME (the bus number for a bus, zone or area, <I>_<J>_<CKT> for a branch). A name longer than RAW's field raises: 12 characters for a bus, zone or area, 40 for a branch, switch or transformer.

To see the INFO messages, enable logging:

import logging

logging.basicConfig(level=logging.INFO)

A bus's AREA

CIM has no association from a node to a control area, so the exporter traces each bus's AREA from what CIM does place in one:

  • the bus of every SynchronousMachine and PowerElectronicsConnection takes its unit's ControlArea;
  • a terminal that holds a TieFlow pair takes the pair's positiveFlowIn = false area, and the other terminals of that device take the true (home) area;
  • the area then spreads across every device with two or more nodes and no TieFlow.

A bus in a group of buses with no such seed gets no AREA: it is written blank, and RAW reads a blank AREA as its default. The importer lists these buses as untranscribed: area=<AREA>. Two areas meeting in one group raise: buses joined inside one area are seeded with ['ca_1', 'ca_2'] (by [...]). A load's AREA is its own, from its load group.

Ratings in MVA or in current

RATE1 to RATE12 of a branch, switch or transformer winding are the limits whose type is olt_rate<n> (0 where there is none). A model whose limit types are named otherwise passes the mapping, OperationalLimitType mRID to set number: cim_to_raw(network, "case.raw", rating_sets={"olt_normal": 1, "olt_emergency": 2}), or RawExporter(rating_sets=...). Each type takes its own set 1 to 12, and only the types named count. They are in MVA when the limits are ApparentPowerLimits. When they are CurrentLimits, the exporter writes NXFRAT (branches and switches) or XFRRAT (transformers) as 1 and each RATE as a current expressed as MVA, the square root of 3 times the device's base voltage in kV times the current in kA. A case, or one device, with both kinds raises, because RAW's flag is one or the other, and so does a limit of any other type.

What it refuses

to_model first checks every ConductingEquipment class in the network against the classes the modules above export, and raises before it writes anything:

ValueError: no RAW export yet for {'CsConverter': 8}

The message names each unexported class and its count. Today DC lines (CsConverter, VsConverter) are imported but not yet exported, so a case that has them imports and then raises here. What converts lists them.

The exporter also raises on CIM it cannot say in RAW. Most often:

CIM Result
a branch with a line conductance (gch) RAW has none
a switch with a ConnectivityNode at one terminal only a switch is between two buses
a nonlinear shunt, or a shunt block with a conductance not in RAW
an exponent load response a RAW load is ZIP only
a shunt whose rated voltage is not its bus's base voltage RAW states a shunt at the bus voltage
a generator plant whose machines disagree on the regulated bus, set point or reactive share PSS/E treats them as one
a step-up transformer that is out of service, has a tap that moves, or is rated off its bus voltage a RAW step-up has none of these
a transformer with a winding on a node that has no bus number not a RAW transformer
a transformer with a tap control on both windings of two, or a phase shifter under a voltage control not in RAW
an impedance correction table that no winding uses no base to convert its ratios

Each message names the object. A SUBSTATION block (nodes, switching devices, equipment terminals) imports to CIM but is not yet exported: a case with node-breaker data comes back as a bus-branch case, and a switch between two ConnectivityNodes is left out, with one warning on the log that counts them.

Writing the case

Raw34Writer().write(model, destination) writes the whole file. It is the reader's mirror and walks the same layout:

  • Fields are written by position. A None field is blank (two commas in a row), and trailing blank fields are left off. Nothing is defaulted, so the writer writes back only what it was given.
  • A float is written with the precision the schema gives when that reads back as the same number, otherwise in the shortest exact form. A string is padded to the field's width and quoted as the schema says.
  • Records come out in the model's order, which is the file order for a model the reader built.
  • The two title lines are written as given, always two. A case with more than two raises.
  • Bus references are written as numbers, never as extended names.
  • Every section ends with 0 / END OF <section> DATA, BEGIN <next> DATA, and the file ends with Q.
  • A model with multi-terminal DC or GNE records raises NotImplementedError. Writing a model with no case identification record raises ValueError.

Raw34Writer().serialize(record) returns one record's text, and lines(model) the whole file as a list of lines.