Class: FactsDeviceRecord¶
FACTS control device data record
classDiagram
class FactsDeviceRecord
click FactsDeviceRecord href "../FactsDeviceRecord/"
FactsDeviceRecord : ibus
FactsDeviceRecord : imx
FactsDeviceRecord : jbus
FactsDeviceRecord : linx
FactsDeviceRecord : mname
FactsDeviceRecord : mode
FactsDeviceRecord : name
FactsDeviceRecord : nreg
FactsDeviceRecord : owner
FactsDeviceRecord : pdes
FactsDeviceRecord : qdes
FactsDeviceRecord : remot
FactsDeviceRecord : rmpct
FactsDeviceRecord : set1
FactsDeviceRecord : set2
FactsDeviceRecord : shmx
FactsDeviceRecord : trmx
FactsDeviceRecord : vset
FactsDeviceRecord : vsmx
FactsDeviceRecord : vsref
FactsDeviceRecord : vtmn
FactsDeviceRecord : vtmx
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| name | 1 String |
NAME - FACTS device name | direct |
| ibus | 1 Integer |
I - Sending end bus number or extended bus name | direct |
| jbus | 0..1 Integer |
J - Terminal end bus number or extended bus name (0 for a STATCON) | direct |
| mode | 0..1 Integer |
MODE - Control mode | direct |
| pdes | 0..1 Float |
PDES - Desired active power flow in MW | direct |
| qdes | 0..1 Float |
QDES - Desired reactive power flow in MVAr | direct |
| vset | 0..1 Float |
VSET - Voltage setpoint in pu | direct |
| shmx | 0..1 Float |
SHMX - Maximum shunt current in MVA at unity voltage | direct |
| trmx | 0..1 Float |
TRMX - Maximum bridge active power transfer in MW | direct |
| vtmn | 0..1 Float |
VTMN - Minimum voltage limit at the terminal end bus in pu | direct |
| vtmx | 0..1 Float |
VTMX - Maximum voltage limit at the terminal end bus in pu | direct |
| vsmx | 0..1 Float |
VSMX - Maximum series voltage in pu | direct |
| imx | 0..1 Float |
IMX - Maximum series current in MVA at unity voltage (0 for no limit) | direct |
| linx | 0..1 Float |
LINX - Reactance of dummy series element in pu | direct |
| rmpct | 0..1 Float |
RMPCT - Percent of required Mvar supplied by the shunt element (must be posit... | direct |
| owner | 0..1 Integer |
OWNER - Owner number | direct |
| set1 | 0..1 Float |
SET1 - Series setpoint 1 (R for MODE 3; magnitude or Vd for MODE 4, 7, 8) | direct |
| set2 | 0..1 Float |
SET2 - Series setpoint 2 (X for MODE 3; angle or Vq for MODE 4, 7, 8) | direct |
| vsref | 0..1 Integer |
VSREF - Series voltage reference code (0 sending end voltage, 1 series curren... | direct |
| remot | 0..1 Integer |
FCREG - Bus number or extended bus name of the bus whose voltage the shunt re... | direct |
| mname | 0..1 String |
MNAME - Name of the master FACTS device when this device is an IPFC slave (MO... | direct |
| nreg | 0..1 Integer |
NREG - Node number of bus FCREG (0 if FCREG is not in a substation) | direct |
Usages¶
| used by | used in | type | used |
|---|---|---|---|
| RawModel | facts_device_records | range | FactsDeviceRecord |
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridappsd.org/cimhub/raw_v34
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | raw:FactsDeviceRecord |
| native | raw:FactsDeviceRecord |
LinkML Source¶
Direct¶
name: FactsDeviceRecord
description: FACTS control device data record
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
name:
name: name
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
width:
tag: width
value: 12
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
description: NAME - FACTS device name
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
domain_of:
- BusRecord
- BranchRecord
- SwitchRecord
- TransformerRecord
- AreaInterchangeRecord
- TwoTerminalDCRecord
- VscDcRecord
- MultiTerminalDCRecord
- FactsDeviceRecord
- GneDeviceRecord
- InductionMachineRecord
- SubstationRecord
- SubstationNodeRecord
- StationSwitchingDeviceRecord
range: string
required: true
ibus:
name: ibus
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: int
description: I - Sending end bus number or extended bus name
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: integer
required: true
jbus:
name: jbus
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: J - Terminal end bus number or extended bus name (0 for a STATCON)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: integer
required: false
mode:
name: mode
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: MODE - Control mode
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: integer
required: false
pdes:
name: pdes
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: PDES - Desired active power flow in MW
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
domain_of:
- AreaInterchangeRecord
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MW
qdes:
name: qdes
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: QDES - Desired reactive power flow in MVAr
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MVAr
vset:
name: vset
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: VSET - Voltage setpoint in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
shmx:
name: shmx
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 9999.0
description: SHMX - Maximum shunt current in MVA at unity voltage
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MVA
trmx:
name: trmx
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 9999.0
description: TRMX - Maximum bridge active power transfer in MW
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MW
vtmn:
name: vtmn
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.9
description: VTMN - Minimum voltage limit at the terminal end bus in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
vtmx:
name: vtmx
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.1
description: VTMX - Maximum voltage limit at the terminal end bus in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
vsmx:
name: vsmx
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: VSMX - Maximum series voltage in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
imx:
name: imx
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: IMX - Maximum series current in MVA at unity voltage (0 for no limit)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MVA
linx:
name: linx
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.05
description: LINX - Reactance of dummy series element in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
rmpct:
name: rmpct
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 100.0
description: RMPCT - Percent of required Mvar supplied by the shunt element (must
be positive)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
domain_of:
- GeneratorRecord
- FactsDeviceRecord
- SwitchedShuntRecord
range: float
required: false
owner:
name: owner
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: OWNER - Owner number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
domain_of:
- BusRecord
- LoadRecord
- MultiTerminalDCBusRecord
- FactsDeviceRecord
- GneDeviceRecord
- InductionMachineRecord
range: integer
required: false
set1:
name: set1
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: SET1 - Series setpoint 1 (R for MODE 3; magnitude or Vd for MODE
4, 7, 8)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
set2:
name: set2
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: SET2 - Series setpoint 2 (X for MODE 3; angle or Vq for MODE 4, 7,
8)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: float
required: false
vsref:
name: vsref
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: VSREF - Series voltage reference code (0 sending end voltage, 1 series
current)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: integer
required: false
remot:
name: remot
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: FCREG - Bus number or extended bus name of the bus whose voltage
the shunt regulates (0 for sending end)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: integer
required: false
mname:
name: mname
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: string
width:
tag: width
value: 12
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
raw_default:
tag: raw_default
value: ''
description: MNAME - Name of the master FACTS device when this device is an IPFC
slave (MODE 6 or 8)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
domain_of:
- FactsDeviceRecord
range: string
required: false
nreg:
name: nreg
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: NREG - Node number of bus FCREG (0 if FCREG is not in a substation)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
domain_of:
- GeneratorRecord
- FactsDeviceRecord
- SwitchedShuntRecord
range: integer
required: false
Induced¶
name: FactsDeviceRecord
description: FACTS control device data record
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
name:
name: name
annotations:
order:
tag: order
value: 1
value_type:
tag: value_type
value: string
width:
tag: width
value: 12
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
description: NAME - FACTS device name
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
owner: FactsDeviceRecord
domain_of:
- BusRecord
- BranchRecord
- SwitchRecord
- TransformerRecord
- AreaInterchangeRecord
- TwoTerminalDCRecord
- VscDcRecord
- MultiTerminalDCRecord
- FactsDeviceRecord
- GneDeviceRecord
- InductionMachineRecord
- SubstationRecord
- SubstationNodeRecord
- StationSwitchingDeviceRecord
range: string
required: true
ibus:
name: ibus
annotations:
order:
tag: order
value: 2
value_type:
tag: value_type
value: int
description: I - Sending end bus number or extended bus name
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: integer
required: true
jbus:
name: jbus
annotations:
order:
tag: order
value: 3
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: J - Terminal end bus number or extended bus name (0 for a STATCON)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: integer
required: false
mode:
name: mode
annotations:
order:
tag: order
value: 4
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: MODE - Control mode
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: integer
required: false
pdes:
name: pdes
annotations:
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: PDES - Desired active power flow in MW
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
owner: FactsDeviceRecord
domain_of:
- AreaInterchangeRecord
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MW
qdes:
name: qdes
annotations:
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: QDES - Desired reactive power flow in MVAr
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MVAr
vset:
name: vset
annotations:
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: VSET - Voltage setpoint in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
shmx:
name: shmx
annotations:
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 9999.0
description: SHMX - Maximum shunt current in MVA at unity voltage
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MVA
trmx:
name: trmx
annotations:
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 9999.0
description: TRMX - Maximum bridge active power transfer in MW
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MW
vtmn:
name: vtmn
annotations:
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.9
description: VTMN - Minimum voltage limit at the terminal end bus in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
vtmx:
name: vtmx
annotations:
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.1
description: VTMX - Maximum voltage limit at the terminal end bus in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
vsmx:
name: vsmx
annotations:
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: VSMX - Maximum series voltage in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
imx:
name: imx
annotations:
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: IMX - Maximum series current in MVA at unity voltage (0 for no limit)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
unit:
ucum_code: MVA
linx:
name: linx
annotations:
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.05
description: LINX - Reactance of dummy series element in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
rmpct:
name: rmpct
annotations:
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 100.0
description: RMPCT - Percent of required Mvar supplied by the shunt element (must
be positive)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
owner: FactsDeviceRecord
domain_of:
- GeneratorRecord
- FactsDeviceRecord
- SwitchedShuntRecord
range: float
required: false
owner:
name: owner
annotations:
order:
tag: order
value: 16
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: OWNER - Owner number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
owner: FactsDeviceRecord
domain_of:
- BusRecord
- LoadRecord
- MultiTerminalDCBusRecord
- FactsDeviceRecord
- GneDeviceRecord
- InductionMachineRecord
range: integer
required: false
set1:
name: set1
annotations:
order:
tag: order
value: 17
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: SET1 - Series setpoint 1 (R for MODE 3; magnitude or Vd for MODE
4, 7, 8)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
set2:
name: set2
annotations:
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: SET2 - Series setpoint 2 (X for MODE 3; angle or Vq for MODE 4, 7,
8)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: float
required: false
vsref:
name: vsref
annotations:
order:
tag: order
value: 19
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: VSREF - Series voltage reference code (0 sending end voltage, 1 series
current)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: integer
required: false
remot:
name: remot
annotations:
order:
tag: order
value: 20
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: FCREG - Bus number or extended bus name of the bus whose voltage
the shunt regulates (0 for sending end)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: integer
required: false
mname:
name: mname
annotations:
order:
tag: order
value: 21
value_type:
tag: value_type
value: string
width:
tag: width
value: 12
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
raw_default:
tag: raw_default
value: ''
description: MNAME - Name of the master FACTS device when this device is an IPFC
slave (MODE 6 or 8)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
rank: 1000
owner: FactsDeviceRecord
domain_of:
- FactsDeviceRecord
range: string
required: false
nreg:
name: nreg
annotations:
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: NREG - Node number of bus FCREG (0 if FCREG is not in a substation)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/facts_device
owner: FactsDeviceRecord
domain_of:
- GeneratorRecord
- FactsDeviceRecord
- SwitchedShuntRecord
range: integer
required: false