Class: TransformerRecord¶
Transformer data record (2 or 3 winding).
__
Multi-line format:
- Line 1: Basic identification and ownership
- Line 2: Impedance data
- Line 3: Winding 1 data
- Line 4: Winding 2 data
- Line 5: Winding 3 data (only if K != 0)
__
Maps to CIM: cim.PowerTransformer, cim.PowerTransformerEnd
__
classDiagram
class TransformerRecord
click TransformerRecord href "../TransformerRecord/"
TransformerRecord : ang1
TransformerRecord : ang2
TransformerRecord : ang3
TransformerRecord : anstar
TransformerRecord : circuit
TransformerRecord : cm
TransformerRecord : cnxa1
TransformerRecord : cnxa2
TransformerRecord : cnxa3
TransformerRecord : cod1
TransformerRecord : cod2
TransformerRecord : cod3
TransformerRecord : cont1
TransformerRecord : cont2
TransformerRecord : cont3
TransformerRecord : cr1
TransformerRecord : cr2
TransformerRecord : cr3
TransformerRecord : cw
TransformerRecord : cx1
TransformerRecord : cx2
TransformerRecord : cx3
TransformerRecord : cz
TransformerRecord : f1
TransformerRecord : f2
TransformerRecord : f3
TransformerRecord : f4
TransformerRecord : i
TransformerRecord : j
TransformerRecord : k
TransformerRecord : mag1
TransformerRecord : mag2
TransformerRecord : name
TransformerRecord : nmetr
TransformerRecord : nod1
TransformerRecord : nod2
TransformerRecord : nod3
TransformerRecord : nomv1
TransformerRecord : nomv2
TransformerRecord : nomv3
TransformerRecord : ntp1
TransformerRecord : ntp2
TransformerRecord : ntp3
TransformerRecord : o1
TransformerRecord : o2
TransformerRecord : o3
TransformerRecord : o4
TransformerRecord : r1_2
TransformerRecord : r2_3
TransformerRecord : r3_1
TransformerRecord : rate1_1
TransformerRecord : rate1_10
TransformerRecord : rate1_11
TransformerRecord : rate1_12
TransformerRecord : rate1_2
TransformerRecord : rate1_3
TransformerRecord : rate1_4
TransformerRecord : rate1_5
TransformerRecord : rate1_6
TransformerRecord : rate1_7
TransformerRecord : rate1_8
TransformerRecord : rate1_9
TransformerRecord : rate2_1
TransformerRecord : rate2_10
TransformerRecord : rate2_11
TransformerRecord : rate2_12
TransformerRecord : rate2_2
TransformerRecord : rate2_3
TransformerRecord : rate2_4
TransformerRecord : rate2_5
TransformerRecord : rate2_6
TransformerRecord : rate2_7
TransformerRecord : rate2_8
TransformerRecord : rate2_9
TransformerRecord : rate3_1
TransformerRecord : rate3_10
TransformerRecord : rate3_11
TransformerRecord : rate3_12
TransformerRecord : rate3_2
TransformerRecord : rate3_3
TransformerRecord : rate3_4
TransformerRecord : rate3_5
TransformerRecord : rate3_6
TransformerRecord : rate3_7
TransformerRecord : rate3_8
TransformerRecord : rate3_9
TransformerRecord : rma1
TransformerRecord : rma2
TransformerRecord : rma3
TransformerRecord : rmi1
TransformerRecord : rmi2
TransformerRecord : rmi3
TransformerRecord : sbase1_2
TransformerRecord : sbase2_3
TransformerRecord : sbase3_1
TransformerRecord : status
TransformerRecord : tab1
TransformerRecord : tab2
TransformerRecord : tab3
TransformerRecord : vecgrp
TransformerRecord : vma1
TransformerRecord : vma2
TransformerRecord : vma3
TransformerRecord : vmi1
TransformerRecord : vmi2
TransformerRecord : vmi3
TransformerRecord : vmstar
TransformerRecord : windv1
TransformerRecord : windv2
TransformerRecord : windv3
TransformerRecord : x1_2
TransformerRecord : x2_3
TransformerRecord : x3_1
TransformerRecord : zcod
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| i | 1 Integer |
I - Winding 1 bus number | direct |
| j | 1 Integer |
J - Winding 2 bus number | direct |
| k | 0..1 Integer |
K - Winding 3 bus number (0 for 2-winding) | direct |
| circuit | 0..1 String |
CKT - Circuit identifier (1 or 2 characters) | direct |
| cw | 0..1 Integer |
CW - Winding data I/O code | direct |
| cz | 0..1 Integer |
CZ - Impedance data I/O code | direct |
| cm | 0..1 Integer |
CM - Magnetizing admittance I/O code | direct |
| mag1 | 0..1 Float |
MAG1 - Magnetizing conductance in pu (CM 1, system MVA base) or no-load loss ... | direct |
| mag2 | 0..1 Float |
MAG2 - Magnetizing susceptance in pu (CM 1, system MVA base) or exciting curr... | direct |
| nmetr | 0..1 Integer |
NMETR - Non-metered end code (1, 2, or 3; the winding whose bus is not metere... | direct |
| name | 0..1 String |
NAME - Transformer name (40 characters) | direct |
| status | 0..1 Integer |
STAT - Transformer status (0 out of service, 1 in service; 3-winding also 2, ... | direct |
| o1 | 0..1 Integer |
O1 - Owner 1 number | direct |
| f1 | 0..1 Float |
F1 - Fraction of ownership for owner 1 | direct |
| o2 | 0..1 Integer |
O2 - Owner 2 number | direct |
| f2 | 0..1 Float |
F2 - Fraction of ownership for owner 2 | direct |
| o3 | 0..1 Integer |
O3 - Owner 3 number | direct |
| f3 | 0..1 Float |
F3 - Fraction of ownership for owner 3 | direct |
| o4 | 0..1 Integer |
O4 - Owner 4 number | direct |
| f4 | 0..1 Float |
F4 - Fraction of ownership for owner 4 | direct |
| vecgrp | 0..1 String |
VECGRP - Vector group (12 characters) | direct |
| zcod | 0..1 Integer |
ZCOD - Impedance correction method (0 winding impedances, 1 bus-to-bus impeda... | direct |
| r1_2 | 0..1 Float |
R1-2 - Winding 1-2 resistance in pu (CZ 1 system base, CZ 2 SBASE1-2) or load... | direct |
| x1_2 | 1 Float |
X1-2 - Winding 1-2 reactance in pu (CZ 1 system base, CZ 2 SBASE1-2) or imped... | direct |
| sbase1_2 | 0..1 Float |
SBASE1-2 - Winding 1-2 base MVA | direct |
| r2_3 | 0..1 Float |
R2-3 - Winding 2-3 resistance in pu (CZ 1 system base, CZ 2 SBASE2-3) or load... | direct |
| x2_3 | 0..1 Float |
X2-3 - Winding 2-3 reactance in pu (CZ 1 system base, CZ 2 SBASE2-3) or imped... | direct |
| sbase2_3 | 0..1 Float |
SBASE2-3 - Winding 2-3 base MVA (3-winding only) | direct |
| r3_1 | 0..1 Float |
R3-1 - Winding 3-1 resistance in pu (CZ 1 system base, CZ 2 SBASE3-1) or load... | direct |
| x3_1 | 0..1 Float |
X3-1 - Winding 3-1 reactance in pu (CZ 1 system base, CZ 2 SBASE3-1) or imped... | direct |
| sbase3_1 | 0..1 Float |
SBASE3-1 - Winding 3-1 base MVA (3-winding only) | direct |
| vmstar | 0..1 Float |
VMSTAR - Star point voltage magnitude in pu | direct |
| anstar | 0..1 Float |
ANSTAR - Star point voltage angle in degrees | direct |
| windv1 | 0..1 Float |
WINDV1 - Winding 1 turns ratio in pu (CW 1 or 3) or voltage in kV (CW 2) | direct |
| nomv1 | 0..1 Float |
NOMV1 - Winding 1 nominal voltage in kV | direct |
| ang1 | 0..1 Float |
ANG1 - Winding 1 phase shift angle in degrees | direct |
| rate1_1 | 0..1 Float |
RATE1-1 - Winding 1 rating 1 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_2 | 0..1 Float |
RATE1-2 - Winding 1 rating 2 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_3 | 0..1 Float |
RATE1-3 - Winding 1 rating 3 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_4 | 0..1 Float |
RATE1-4 - Winding 1 rating 4 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_5 | 0..1 Float |
RATE1-5 - Winding 1 rating 5 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_6 | 0..1 Float |
RATE1-6 - Winding 1 rating 6 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_7 | 0..1 Float |
RATE1-7 - Winding 1 rating 7 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_8 | 0..1 Float |
RATE1-8 - Winding 1 rating 8 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_9 | 0..1 Float |
RATE1-9 - Winding 1 rating 9 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_10 | 0..1 Float |
RATE1-10 - Winding 1 rating 10 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_11 | 0..1 Float |
RATE1-11 - Winding 1 rating 11 in MVA (or current as MVA, per XFRRAT) | direct |
| rate1_12 | 0..1 Float |
RATE1-12 - Winding 1 rating 12 in MVA (or current as MVA, per XFRRAT) | direct |
| cod1 | 0..1 Integer |
COD1 - Winding 1 control mode | direct |
| cont1 | 0..1 Integer |
CONT1 - Winding 1 controlled bus number | direct |
| rma1 | 0..1 Float |
RMA1 - Winding 1 upper limit (pu or kV per CW, or degrees for | COD |
| rmi1 | 0..1 Float |
RMI1 - Winding 1 lower limit (pu or kV per CW, or degrees for | COD |
| vma1 | 0..1 Float |
VMA1 - Winding 1 upper limit (pu bus voltage, Mvar or MW per | COD |
| vmi1 | 0..1 Float |
VMI1 - Winding 1 lower limit (pu bus voltage, Mvar or MW per | COD |
| ntp1 | 0..1 Integer |
NTP1 - Winding 1 number of tap positions | direct |
| tab1 | 0..1 Integer |
TAB1 - Winding 1 tap position table number | direct |
| cr1 | 0..1 Float |
CR1 - Winding 1 load drop compensation resistance in pu | direct |
| cx1 | 0..1 Float |
CX1 - Winding 1 load drop compensation reactance in pu | direct |
| cnxa1 | 0..1 Float |
CNXA1 - Winding 1 connection angle in degrees | direct |
| nod1 | 0..1 Integer |
NOD1 - Winding 1 node number | direct |
| windv2 | 0..1 Float |
WINDV2 - Winding 2 turns ratio in pu (CW 1 or 3) or voltage in kV (CW 2) | direct |
| nomv2 | 0..1 Float |
NOMV2 - Winding 2 nominal voltage in kV | direct |
| ang2 | 0..1 Float |
ANG2 - Winding 2 phase shift angle in degrees | direct |
| rate2_1 | 0..1 Float |
RATE2-1 - Winding 2 rating 1 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_2 | 0..1 Float |
RATE2-2 - Winding 2 rating 2 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_3 | 0..1 Float |
RATE2-3 - Winding 2 rating 3 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_4 | 0..1 Float |
RATE2-4 - Winding 2 rating 4 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_5 | 0..1 Float |
RATE2-5 - Winding 2 rating 5 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_6 | 0..1 Float |
RATE2-6 - Winding 2 rating 6 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_7 | 0..1 Float |
RATE2-7 - Winding 2 rating 7 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_8 | 0..1 Float |
RATE2-8 - Winding 2 rating 8 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_9 | 0..1 Float |
RATE2-9 - Winding 2 rating 9 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_10 | 0..1 Float |
RATE2-10 - Winding 2 rating 10 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_11 | 0..1 Float |
RATE2-11 - Winding 2 rating 11 in MVA (or current as MVA, per XFRRAT) | direct |
| rate2_12 | 0..1 Float |
RATE2-12 - Winding 2 rating 12 in MVA (or current as MVA, per XFRRAT) | direct |
| cod2 | 0..1 Integer |
COD2 - Winding 2 control mode | direct |
| cont2 | 0..1 Integer |
CONT2 - Winding 2 controlled bus number | direct |
| rma2 | 0..1 Float |
RMA2 - Winding 2 upper limit (pu or kV per CW, or degrees for | COD |
| rmi2 | 0..1 Float |
RMI2 - Winding 2 lower limit (pu or kV per CW, or degrees for | COD |
| vma2 | 0..1 Float |
VMA2 - Winding 2 upper limit (pu bus voltage, Mvar or MW per | COD |
| vmi2 | 0..1 Float |
VMI2 - Winding 2 lower limit (pu bus voltage, Mvar or MW per | COD |
| ntp2 | 0..1 Integer |
NTP2 - Winding 2 number of tap positions | direct |
| tab2 | 0..1 Integer |
TAB2 - Winding 2 tap position table number | direct |
| cr2 | 0..1 Float |
CR2 - Winding 2 load drop compensation resistance in pu | direct |
| cx2 | 0..1 Float |
CX2 - Winding 2 load drop compensation reactance in pu | direct |
| cnxa2 | 0..1 Float |
CNXA2 - Winding 2 connection angle in degrees | direct |
| nod2 | 0..1 Integer |
NOD2 - Winding 2 node number | direct |
| windv3 | 0..1 Float |
WINDV3 - Winding 3 turns ratio in pu (CW 1 or 3) or voltage in kV (CW 2) | direct |
| nomv3 | 0..1 Float |
NOMV3 - Winding 3 nominal voltage in kV | direct |
| ang3 | 0..1 Float |
ANG3 - Winding 3 phase shift angle in degrees | direct |
| rate3_1 | 0..1 Float |
RATE3-1 - Winding 3 rating 1 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_2 | 0..1 Float |
RATE3-2 - Winding 3 rating 2 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_3 | 0..1 Float |
RATE3-3 - Winding 3 rating 3 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_4 | 0..1 Float |
RATE3-4 - Winding 3 rating 4 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_5 | 0..1 Float |
RATE3-5 - Winding 3 rating 5 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_6 | 0..1 Float |
RATE3-6 - Winding 3 rating 6 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_7 | 0..1 Float |
RATE3-7 - Winding 3 rating 7 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_8 | 0..1 Float |
RATE3-8 - Winding 3 rating 8 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_9 | 0..1 Float |
RATE3-9 - Winding 3 rating 9 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_10 | 0..1 Float |
RATE3-10 - Winding 3 rating 10 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_11 | 0..1 Float |
RATE3-11 - Winding 3 rating 11 in MVA (or current as MVA, per XFRRAT) | direct |
| rate3_12 | 0..1 Float |
RATE3-12 - Winding 3 rating 12 in MVA (or current as MVA, per XFRRAT) | direct |
| cod3 | 0..1 Integer |
COD3 - Winding 3 control mode | direct |
| cont3 | 0..1 Integer |
CONT3 - Winding 3 controlled bus number | direct |
| rma3 | 0..1 Float |
RMA3 - Winding 3 upper limit (pu or kV per CW, or degrees for | COD |
| rmi3 | 0..1 Float |
RMI3 - Winding 3 lower limit (pu or kV per CW, or degrees for | COD |
| vma3 | 0..1 Float |
VMA3 - Winding 3 upper limit (pu bus voltage, Mvar or MW per | COD |
| vmi3 | 0..1 Float |
VMI3 - Winding 3 lower limit (pu bus voltage, Mvar or MW per | COD |
| ntp3 | 0..1 Integer |
NTP3 - Winding 3 number of tap positions | direct |
| tab3 | 0..1 Integer |
TAB3 - Winding 3 tap position table number | direct |
| cr3 | 0..1 Float |
CR3 - Winding 3 load drop compensation resistance in pu | direct |
| cx3 | 0..1 Float |
CX3 - Winding 3 load drop compensation reactance in pu | direct |
| cnxa3 | 0..1 Float |
CNXA3 - Winding 3 connection angle in degrees | direct |
| nod3 | 0..1 Integer |
NOD3 - Winding 3 node number | direct |
Usages¶
| used by | used in | type | used |
|---|---|---|---|
| RawModel | transformer_records | range | TransformerRecord |
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://gridappsd.org/cimhub/raw_v34
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | raw:TransformerRecord |
| native | raw:TransformerRecord |
LinkML Source¶
Direct¶
name: TransformerRecord
description: 'Transformer data record (2 or 3 winding).
Multi-line format:
- Line 1: Basic identification and ownership
- Line 2: Impedance data
- Line 3: Winding 1 data
- Line 4: Winding 2 data
- Line 5: Winding 3 data (only if K != 0)
Maps to CIM: cim.PowerTransformer, cim.PowerTransformerEnd
'
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
i:
name: i
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 1
value_type:
tag: value_type
value: int
description: I - Winding 1 bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
- MultiSectionLineRecord
range: integer
required: true
j:
name: j
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 2
value_type:
tag: value_type
value: int
description: J - Winding 2 bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
- MultiSectionLineRecord
range: integer
required: true
k:
name: k
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 3
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: K - Winding 3 bus number (0 for 2-winding)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
circuit:
name: circuit
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
width:
tag: width
value: 2
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
raw_default:
tag: raw_default
value: '1'
description: CKT - Circuit identifier (1 or 2 characters)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- BranchRecord
- SwitchRecord
- TransformerRecord
- StationSwitchingDeviceRecord
range: string
required: false
cw:
name: cw
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 5
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: CW - Winding data I/O code
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
cz:
name: cz
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 6
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: CZ - Impedance data I/O code
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
cm:
name: cm
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 7
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: CM - Magnetizing admittance I/O code
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
mag1:
name: mag1
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: MAG1 - Magnetizing conductance in pu (CM 1, system MVA base) or no-load
loss in W (CM 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
mag2:
name: mag2
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: MAG2 - Magnetizing susceptance in pu (CM 1, system MVA base) or exciting
current in pu (CM 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
nmetr:
name: nmetr
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 10
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 2
description: NMETR - Non-metered end code (1, 2, or 3; the winding whose bus is
not metered)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
- GneDeviceRecord
range: integer
required: false
name:
name: name
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 11
value_type:
tag: value_type
value: string
width:
tag: width
value: 40
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
raw_default:
tag: raw_default
value: ''
description: NAME - Transformer name (40 characters)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- BusRecord
- BranchRecord
- SwitchRecord
- TransformerRecord
- AreaInterchangeRecord
- TwoTerminalDCRecord
- VscDcRecord
- MultiTerminalDCRecord
- FactsDeviceRecord
- GneDeviceRecord
- InductionMachineRecord
- SubstationRecord
- SubstationNodeRecord
- StationSwitchingDeviceRecord
range: string
required: false
status:
name: status
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 12
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: STAT - Transformer status (0 out of service, 1 in service; 3-winding
also 2, 3, 4 = one winding out)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- LoadRecord
- FixedShuntRecord
- GeneratorRecord
- BranchRecord
- SwitchRecord
- TransformerRecord
- SwitchedShuntRecord
- GneDeviceRecord
- InductionMachineRecord
- SubstationNodeRecord
- StationSwitchingDeviceRecord
range: integer
required: false
o1:
name: o1
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 13
value_type:
tag: value_type
value: int
raw_default_rule:
tag: raw_default_rule
value: owner assigned to bus I
description: O1 - Owner 1 number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: integer
required: false
f1:
name: f1
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: F1 - Fraction of ownership for owner 1
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: float
required: false
o2:
name: o2
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 15
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: O2 - Owner 2 number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: integer
required: false
f2:
name: f2
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 16
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: F2 - Fraction of ownership for owner 2
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: float
required: false
o3:
name: o3
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 17
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: O3 - Owner 3 number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: integer
required: false
f3:
name: f3
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: F3 - Fraction of ownership for owner 3
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: float
required: false
o4:
name: o4
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 19
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: O4 - Owner 4 number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: integer
required: false
f4:
name: f4
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: F4 - Fraction of ownership for owner 4
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: float
required: false
vecgrp:
name: vecgrp
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 21
value_type:
tag: value_type
value: string
width:
tag: width
value: 12
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
raw_default:
tag: raw_default
value: ''
description: VECGRP - Vector group (12 characters)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: string
required: false
zcod:
name: zcod
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: ZCOD - Impedance correction method (0 winding impedances, 1 bus-to-bus
impedances); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
r1_2:
name: r1_2
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 1
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default:
tag: raw_default
value: 0.0
description: R1-2 - Winding 1-2 resistance in pu (CZ 1 system base, CZ 2 SBASE1-2)
or load loss in W (CZ 3)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
x1_2:
name: x1_2
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
description: X1-2 - Winding 1-2 reactance in pu (CZ 1 system base, CZ 2 SBASE1-2)
or impedance magnitude in pu (CZ 3)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: true
sbase1_2:
name: sbase1_2
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default_rule:
tag: raw_default_rule
value: SBASE (system base MVA)
description: SBASE1-2 - Winding 1-2 base MVA
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
r2_3:
name: r2_3
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: R2-3 - Winding 2-3 resistance in pu (CZ 1 system base, CZ 2 SBASE2-3)
or load loss in W (CZ 3); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
x2_3:
name: x2_3
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
description: X2-3 - Winding 2-3 reactance in pu (CZ 1 system base, CZ 2 SBASE2-3)
or impedance magnitude in pu (CZ 3); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
sbase2_3:
name: sbase2_3
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: SBASE (system base MVA)
description: SBASE2-3 - Winding 2-3 base MVA (3-winding only)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
r3_1:
name: r3_1
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: R3-1 - Winding 3-1 resistance in pu (CZ 1 system base, CZ 2 SBASE3-1)
or load loss in W (CZ 3); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
x3_1:
name: x3_1
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
description: X3-1 - Winding 3-1 reactance in pu (CZ 1 system base, CZ 2 SBASE3-1)
or impedance magnitude in pu (CZ 3); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
sbase3_1:
name: sbase3_1
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: SBASE (system base MVA)
description: SBASE3-1 - Winding 3-1 base MVA (3-winding only)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
vmstar:
name: vmstar
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 1.0
description: VMSTAR - Star point voltage magnitude in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
anstar:
name: anstar
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: ANSTAR - Star point voltage angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
windv1:
name: windv1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 1
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 1.0 if CW is 1 or 3; bus I base voltage if CW is 2
description: WINDV1 - Winding 1 turns ratio in pu (CW 1 or 3) or voltage in kV
(CW 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
nomv1:
name: nomv1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: NOMV1 - Winding 1 nominal voltage in kV
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: kV
ang1:
name: ang1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: ANG1 - Winding 1 phase shift angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
rate1_1:
name: rate1_1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-1 - Winding 1 rating 1 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_2:
name: rate1_2
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-2 - Winding 1 rating 2 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_3:
name: rate1_3
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-3 - Winding 1 rating 3 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_4:
name: rate1_4
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-4 - Winding 1 rating 4 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_5:
name: rate1_5
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-5 - Winding 1 rating 5 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_6:
name: rate1_6
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-6 - Winding 1 rating 6 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_7:
name: rate1_7
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-7 - Winding 1 rating 7 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_8:
name: rate1_8
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-8 - Winding 1 rating 8 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_9:
name: rate1_9
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-9 - Winding 1 rating 9 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_10:
name: rate1_10
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-10 - Winding 1 rating 10 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_11:
name: rate1_11
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-11 - Winding 1 rating 11 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_12:
name: rate1_12
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-12 - Winding 1 rating 12 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
cod1:
name: cod1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 16
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: COD1 - Winding 1 control mode
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
cont1:
name: cont1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 17
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: CONT1 - Winding 1 controlled bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
rma1:
name: rma1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 1.1 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMA1 - Winding 1 upper limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
rmi1:
name: rmi1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 0.9 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMI1 - Winding 1 lower limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
vma1:
name: vma1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 1.1 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMA1 - Winding 1 upper limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
vmi1:
name: vmi1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 0.9 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMI1 - Winding 1 lower limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
ntp1:
name: ntp1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 33
description: NTP1 - Winding 1 number of tap positions
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
tab1:
name: tab1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 23
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: TAB1 - Winding 1 tap position table number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
cr1:
name: cr1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default:
tag: raw_default
value: 0.0
description: CR1 - Winding 1 load drop compensation resistance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
cx1:
name: cx1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default:
tag: raw_default
value: 0.0
description: CX1 - Winding 1 load drop compensation reactance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
cnxa1:
name: cnxa1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default:
tag: raw_default
value: 0.0
description: CNXA1 - Winding 1 connection angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
nod1:
name: nod1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 27
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: NOD1 - Winding 1 node number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
windv2:
name: windv2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 1
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 1.0 if CW is 1 or 3; bus J base voltage if CW is 2
description: WINDV2 - Winding 2 turns ratio in pu (CW 1 or 3) or voltage in kV
(CW 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
nomv2:
name: nomv2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: NOMV2 - Winding 2 nominal voltage in kV
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: kV
ang2:
name: ang2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: ANG2 - Winding 2 phase shift angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
rate2_1:
name: rate2_1
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-1 - Winding 2 rating 1 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_2:
name: rate2_2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-2 - Winding 2 rating 2 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_3:
name: rate2_3
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-3 - Winding 2 rating 3 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_4:
name: rate2_4
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-4 - Winding 2 rating 4 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_5:
name: rate2_5
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-5 - Winding 2 rating 5 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_6:
name: rate2_6
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-6 - Winding 2 rating 6 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_7:
name: rate2_7
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-7 - Winding 2 rating 7 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_8:
name: rate2_8
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-8 - Winding 2 rating 8 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_9:
name: rate2_9
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-9 - Winding 2 rating 9 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_10:
name: rate2_10
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-10 - Winding 2 rating 10 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_11:
name: rate2_11
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-11 - Winding 2 rating 11 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_12:
name: rate2_12
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-12 - Winding 2 rating 12 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
cod2:
name: cod2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 16
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: COD2 - Winding 2 control mode
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
cont2:
name: cont2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 17
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: CONT2 - Winding 2 controlled bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
rma2:
name: rma2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.1 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMA2 - Winding 2 upper limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
rmi2:
name: rmi2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 0.9 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMI2 - Winding 2 lower limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
vma2:
name: vma2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.1 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMA2 - Winding 2 upper limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
vmi2:
name: vmi2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 0.9 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMI2 - Winding 2 lower limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
ntp2:
name: ntp2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 33
description: NTP2 - Winding 2 number of tap positions
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
tab2:
name: tab2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 23
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: TAB2 - Winding 2 tap position table number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
cr2:
name: cr2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CR2 - Winding 2 load drop compensation resistance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
cx2:
name: cx2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CX2 - Winding 2 load drop compensation reactance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
cnxa2:
name: cnxa2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CNXA2 - Winding 2 connection angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
nod2:
name: nod2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 27
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: NOD2 - Winding 2 node number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
windv3:
name: windv3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 1
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.0 if CW is 1 or 3; bus K base voltage if CW is 2
description: WINDV3 - Winding 3 turns ratio in pu (CW 1 or 3) or voltage in kV
(CW 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
nomv3:
name: nomv3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: NOMV3 - Winding 3 nominal voltage in kV
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: kV
ang3:
name: ang3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: ANG3 - Winding 3 phase shift angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
rate3_1:
name: rate3_1
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-1 - Winding 3 rating 1 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_2:
name: rate3_2
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-2 - Winding 3 rating 2 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_3:
name: rate3_3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-3 - Winding 3 rating 3 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_4:
name: rate3_4
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-4 - Winding 3 rating 4 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_5:
name: rate3_5
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-5 - Winding 3 rating 5 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_6:
name: rate3_6
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-6 - Winding 3 rating 6 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_7:
name: rate3_7
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-7 - Winding 3 rating 7 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_8:
name: rate3_8
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-8 - Winding 3 rating 8 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_9:
name: rate3_9
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-9 - Winding 3 rating 9 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_10:
name: rate3_10
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-10 - Winding 3 rating 10 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_11:
name: rate3_11
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-11 - Winding 3 rating 11 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_12:
name: rate3_12
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-12 - Winding 3 rating 12 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
cod3:
name: cod3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 16
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: COD3 - Winding 3 control mode
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
cont3:
name: cont3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 17
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: CONT3 - Winding 3 controlled bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
rma3:
name: rma3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.1 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMA3 - Winding 3 upper limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
rmi3:
name: rmi3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 0.9 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMI3 - Winding 3 lower limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
vma3:
name: vma3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.1 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMA3 - Winding 3 upper limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
vmi3:
name: vmi3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 0.9 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMI3 - Winding 3 lower limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
ntp3:
name: ntp3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 33
description: NTP3 - Winding 3 number of tap positions
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
tab3:
name: tab3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 23
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: TAB3 - Winding 3 tap position table number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
cr3:
name: cr3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CR3 - Winding 3 load drop compensation resistance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
cx3:
name: cx3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CX3 - Winding 3 load drop compensation reactance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
cnxa3:
name: cnxa3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CNXA3 - Winding 3 connection angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
nod3:
name: nod3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 27
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: NOD3 - Winding 3 node number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
domain_of:
- TransformerRecord
range: integer
required: false
Induced¶
name: TransformerRecord
description: 'Transformer data record (2 or 3 winding).
Multi-line format:
- Line 1: Basic identification and ownership
- Line 2: Impedance data
- Line 3: Winding 1 data
- Line 4: Winding 2 data
- Line 5: Winding 3 data (only if K != 0)
Maps to CIM: cim.PowerTransformer, cim.PowerTransformerEnd
'
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
i:
name: i
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 1
value_type:
tag: value_type
value: int
description: I - Winding 1 bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
- MultiSectionLineRecord
range: integer
required: true
j:
name: j
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 2
value_type:
tag: value_type
value: int
description: J - Winding 2 bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
- MultiSectionLineRecord
range: integer
required: true
k:
name: k
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 3
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: K - Winding 3 bus number (0 for 2-winding)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
circuit:
name: circuit
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 4
value_type:
tag: value_type
value: string
width:
tag: width
value: 2
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
raw_default:
tag: raw_default
value: '1'
description: CKT - Circuit identifier (1 or 2 characters)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- BranchRecord
- SwitchRecord
- TransformerRecord
- StationSwitchingDeviceRecord
range: string
required: false
cw:
name: cw
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 5
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: CW - Winding data I/O code
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
cz:
name: cz
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 6
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: CZ - Impedance data I/O code
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
cm:
name: cm
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 7
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: CM - Magnetizing admittance I/O code
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
mag1:
name: mag1
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: MAG1 - Magnetizing conductance in pu (CM 1, system MVA base) or no-load
loss in W (CM 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
mag2:
name: mag2
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: MAG2 - Magnetizing susceptance in pu (CM 1, system MVA base) or exciting
current in pu (CM 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
nmetr:
name: nmetr
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 10
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 2
description: NMETR - Non-metered end code (1, 2, or 3; the winding whose bus is
not metered)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
- GneDeviceRecord
range: integer
required: false
name:
name: name
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 11
value_type:
tag: value_type
value: string
width:
tag: width
value: 40
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
raw_default:
tag: raw_default
value: ''
description: NAME - Transformer name (40 characters)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- BusRecord
- BranchRecord
- SwitchRecord
- TransformerRecord
- AreaInterchangeRecord
- TwoTerminalDCRecord
- VscDcRecord
- MultiTerminalDCRecord
- FactsDeviceRecord
- GneDeviceRecord
- InductionMachineRecord
- SubstationRecord
- SubstationNodeRecord
- StationSwitchingDeviceRecord
range: string
required: false
status:
name: status
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 12
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 1
description: STAT - Transformer status (0 out of service, 1 in service; 3-winding
also 2, 3, 4 = one winding out)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- LoadRecord
- FixedShuntRecord
- GeneratorRecord
- BranchRecord
- SwitchRecord
- TransformerRecord
- SwitchedShuntRecord
- GneDeviceRecord
- InductionMachineRecord
- SubstationNodeRecord
- StationSwitchingDeviceRecord
range: integer
required: false
o1:
name: o1
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 13
value_type:
tag: value_type
value: int
raw_default_rule:
tag: raw_default_rule
value: owner assigned to bus I
description: O1 - Owner 1 number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: integer
required: false
f1:
name: f1
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: F1 - Fraction of ownership for owner 1
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: float
required: false
o2:
name: o2
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 15
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: O2 - Owner 2 number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: integer
required: false
f2:
name: f2
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 16
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: F2 - Fraction of ownership for owner 2
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: float
required: false
o3:
name: o3
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 17
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: O3 - Owner 3 number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: integer
required: false
f3:
name: f3
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: F3 - Fraction of ownership for owner 3
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: float
required: false
o4:
name: o4
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 19
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: O4 - Owner 4 number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: integer
required: false
f4:
name: f4
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 1.0
description: F4 - Fraction of ownership for owner 4
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
owner: TransformerRecord
domain_of:
- GeneratorRecord
- BranchRecord
- TransformerRecord
- VscDcRecord
range: float
required: false
vecgrp:
name: vecgrp
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 21
value_type:
tag: value_type
value: string
width:
tag: width
value: 12
quote:
tag: quote
value: true
quote_char:
tag: quote_char
value: ''''
raw_default:
tag: raw_default
value: ''
description: VECGRP - Vector group (12 characters)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: string
required: false
zcod:
name: zcod
annotations:
line_number:
tag: line_number
value: 1
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: ZCOD - Impedance correction method (0 winding impedances, 1 bus-to-bus
impedances); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
r1_2:
name: r1_2
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 1
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default:
tag: raw_default
value: 0.0
description: R1-2 - Winding 1-2 resistance in pu (CZ 1 system base, CZ 2 SBASE1-2)
or load loss in W (CZ 3)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
x1_2:
name: x1_2
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
description: X1-2 - Winding 1-2 reactance in pu (CZ 1 system base, CZ 2 SBASE1-2)
or impedance magnitude in pu (CZ 3)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: true
sbase1_2:
name: sbase1_2
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default_rule:
tag: raw_default_rule
value: SBASE (system base MVA)
description: SBASE1-2 - Winding 1-2 base MVA
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
r2_3:
name: r2_3
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: R2-3 - Winding 2-3 resistance in pu (CZ 1 system base, CZ 2 SBASE2-3)
or load loss in W (CZ 3); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
x2_3:
name: x2_3
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
description: X2-3 - Winding 2-3 reactance in pu (CZ 1 system base, CZ 2 SBASE2-3)
or impedance magnitude in pu (CZ 3); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
sbase2_3:
name: sbase2_3
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: SBASE (system base MVA)
description: SBASE2-3 - Winding 2-3 base MVA (3-winding only)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
r3_1:
name: r3_1
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: R3-1 - Winding 3-1 resistance in pu (CZ 1 system base, CZ 2 SBASE3-1)
or load loss in W (CZ 3); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
x3_1:
name: x3_1
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
description: X3-1 - Winding 3-1 reactance in pu (CZ 1 system base, CZ 2 SBASE3-1)
or impedance magnitude in pu (CZ 3); 3-winding only
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
sbase3_1:
name: sbase3_1
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: SBASE (system base MVA)
description: SBASE3-1 - Winding 3-1 base MVA (3-winding only)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
vmstar:
name: vmstar
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 1.0
description: VMSTAR - Star point voltage magnitude in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
anstar:
name: anstar
annotations:
line_number:
tag: line_number
value: 2
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: ANSTAR - Star point voltage angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
windv1:
name: windv1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 1
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 1.0 if CW is 1 or 3; bus I base voltage if CW is 2
description: WINDV1 - Winding 1 turns ratio in pu (CW 1 or 3) or voltage in kV
(CW 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
nomv1:
name: nomv1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: NOMV1 - Winding 1 nominal voltage in kV
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: kV
ang1:
name: ang1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: ANG1 - Winding 1 phase shift angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
rate1_1:
name: rate1_1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-1 - Winding 1 rating 1 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_2:
name: rate1_2
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-2 - Winding 1 rating 2 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_3:
name: rate1_3
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-3 - Winding 1 rating 3 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_4:
name: rate1_4
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-4 - Winding 1 rating 4 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_5:
name: rate1_5
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-5 - Winding 1 rating 5 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_6:
name: rate1_6
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-6 - Winding 1 rating 6 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_7:
name: rate1_7
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-7 - Winding 1 rating 7 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_8:
name: rate1_8
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-8 - Winding 1 rating 8 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_9:
name: rate1_9
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-9 - Winding 1 rating 9 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_10:
name: rate1_10
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-10 - Winding 1 rating 10 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_11:
name: rate1_11
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-11 - Winding 1 rating 11 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate1_12:
name: rate1_12
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
raw_default:
tag: raw_default
value: 0.0
description: RATE1-12 - Winding 1 rating 12 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
cod1:
name: cod1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 16
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: COD1 - Winding 1 control mode
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
cont1:
name: cont1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 17
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: CONT1 - Winding 1 controlled bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
rma1:
name: rma1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 1.1 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMA1 - Winding 1 upper limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
rmi1:
name: rmi1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 0.9 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMI1 - Winding 1 lower limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
vma1:
name: vma1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 1.1 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMA1 - Winding 1 upper limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
vmi1:
name: vmi1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 0.9 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMI1 - Winding 1 lower limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
ntp1:
name: ntp1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 33
description: NTP1 - Winding 1 number of tap positions
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
tab1:
name: tab1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 23
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: TAB1 - Winding 1 tap position table number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
cr1:
name: cr1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default:
tag: raw_default
value: 0.0
description: CR1 - Winding 1 load drop compensation resistance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
cx1:
name: cx1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default:
tag: raw_default
value: 0.0
description: CX1 - Winding 1 load drop compensation reactance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
cnxa1:
name: cnxa1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default:
tag: raw_default
value: 0.0
description: CNXA1 - Winding 1 connection angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
nod1:
name: nod1
annotations:
line_number:
tag: line_number
value: 3
order:
tag: order
value: 27
value_type:
tag: value_type
value: int
raw_default:
tag: raw_default
value: 0
description: NOD1 - Winding 1 node number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
windv2:
name: windv2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 1
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
raw_default_rule:
tag: raw_default_rule
value: 1.0 if CW is 1 or 3; bus J base voltage if CW is 2
description: WINDV2 - Winding 2 turns ratio in pu (CW 1 or 3) or voltage in kV
(CW 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
nomv2:
name: nomv2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
raw_default:
tag: raw_default
value: 0.0
description: NOMV2 - Winding 2 nominal voltage in kV
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: kV
ang2:
name: ang2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: ANG2 - Winding 2 phase shift angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
rate2_1:
name: rate2_1
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-1 - Winding 2 rating 1 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_2:
name: rate2_2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-2 - Winding 2 rating 2 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_3:
name: rate2_3
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-3 - Winding 2 rating 3 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_4:
name: rate2_4
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-4 - Winding 2 rating 4 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_5:
name: rate2_5
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-5 - Winding 2 rating 5 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_6:
name: rate2_6
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-6 - Winding 2 rating 6 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_7:
name: rate2_7
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-7 - Winding 2 rating 7 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_8:
name: rate2_8
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-8 - Winding 2 rating 8 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_9:
name: rate2_9
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-9 - Winding 2 rating 9 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_10:
name: rate2_10
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-10 - Winding 2 rating 10 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_11:
name: rate2_11
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-11 - Winding 2 rating 11 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate2_12:
name: rate2_12
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE2-12 - Winding 2 rating 12 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
cod2:
name: cod2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 16
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: COD2 - Winding 2 control mode
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
cont2:
name: cont2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 17
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: CONT2 - Winding 2 controlled bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
rma2:
name: rma2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.1 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMA2 - Winding 2 upper limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
rmi2:
name: rmi2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 0.9 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMI2 - Winding 2 lower limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
vma2:
name: vma2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.1 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMA2 - Winding 2 upper limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
vmi2:
name: vmi2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 0.9 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMI2 - Winding 2 lower limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
ntp2:
name: ntp2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 33
description: NTP2 - Winding 2 number of tap positions
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
tab2:
name: tab2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 23
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: TAB2 - Winding 2 tap position table number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
cr2:
name: cr2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CR2 - Winding 2 load drop compensation resistance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
cx2:
name: cx2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CX2 - Winding 2 load drop compensation reactance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
cnxa2:
name: cnxa2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CNXA2 - Winding 2 connection angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
nod2:
name: nod2
annotations:
line_number:
tag: line_number
value: 4
order:
tag: order
value: 27
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: NOD2 - Winding 2 node number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
windv3:
name: windv3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 1
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.0 if CW is 1 or 3; bus K base voltage if CW is 2
description: WINDV3 - Winding 3 turns ratio in pu (CW 1 or 3) or voltage in kV
(CW 2)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
nomv3:
name: nomv3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 2
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: NOMV3 - Winding 3 nominal voltage in kV
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: kV
ang3:
name: ang3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 3
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 4
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: ANG3 - Winding 3 phase shift angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
rate3_1:
name: rate3_1
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 4
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-1 - Winding 3 rating 1 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_2:
name: rate3_2
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 5
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-2 - Winding 3 rating 2 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_3:
name: rate3_3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 6
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-3 - Winding 3 rating 3 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_4:
name: rate3_4
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 7
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-4 - Winding 3 rating 4 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_5:
name: rate3_5
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 8
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-5 - Winding 3 rating 5 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_6:
name: rate3_6
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 9
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-6 - Winding 3 rating 6 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_7:
name: rate3_7
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 10
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-7 - Winding 3 rating 7 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_8:
name: rate3_8
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 11
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-8 - Winding 3 rating 8 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_9:
name: rate3_9
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 12
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-9 - Winding 3 rating 9 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_10:
name: rate3_10
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 13
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-10 - Winding 3 rating 10 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_11:
name: rate3_11
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 14
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-11 - Winding 3 rating 11 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
rate3_12:
name: rate3_12
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 15
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 2
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: RATE3-12 - Winding 3 rating 12 in MVA (or current as MVA, per XFRRAT)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: MVA
cod3:
name: cod3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 16
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: COD3 - Winding 3 control mode
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
cont3:
name: cont3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 17
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: CONT3 - Winding 3 controlled bus number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
rma3:
name: rma3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 18
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.1 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMA3 - Winding 3 upper limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
rmi3:
name: rmi3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 19
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 0.9 if CW is 1 or 3 and |COD| is not 3 or 5; no default otherwise
description: RMI3 - Winding 3 lower limit (pu or kV per CW, or degrees for |COD|
3 or 5)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
vma3:
name: vma3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 20
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 1.1 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMA3 - Winding 3 upper limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
vmi3:
name: vmi3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 21
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default_rule:
tag: raw_default_rule
value: 0.9 if |COD| is 1; no default for |COD| 2, 3 or 5
description: VMI3 - Winding 3 lower limit (pu bus voltage, Mvar or MW per |COD|)
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
ntp3:
name: ntp3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 22
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 33
description: NTP3 - Winding 3 number of tap positions
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
tab3:
name: tab3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 23
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: TAB3 - Winding 3 tap position table number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false
cr3:
name: cr3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 24
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CR3 - Winding 3 load drop compensation resistance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
cx3:
name: cx3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 25
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CX3 - Winding 3 load drop compensation reactance in pu
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
cnxa3:
name: cnxa3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 26
value_type:
tag: value_type
value: float
precision:
tag: precision
value: 5
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0.0
description: CNXA3 - Winding 3 connection angle in degrees
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: float
required: false
unit:
ucum_code: deg
nod3:
name: nod3
annotations:
line_number:
tag: line_number
value: 5
order:
tag: order
value: 27
value_type:
tag: value_type
value: int
serialize_if:
tag: serialize_if
value: custom:k != 0
raw_default:
tag: raw_default
value: 0
description: NOD3 - Winding 3 node number
from_schema: https://gridappsd.org/cimhub/raw_v34/classes/transformer
rank: 1000
owner: TransformerRecord
domain_of:
- TransformerRecord
range: integer
required: false