Skip to content

Class: MultiTerminalConverterRecord

Converter station record of a multi-terminal DC line (NCONV per line).

__

URI: raw:MultiTerminalConverterRecord

 classDiagram
    class MultiTerminalConverterRecord
    click MultiTerminalConverterRecord href "../MultiTerminalConverterRecord/"
      MultiTerminalConverterRecord : angmn

      MultiTerminalConverterRecord : angmx

      MultiTerminalConverterRecord : cnvcod

      MultiTerminalConverterRecord : dcpf

      MultiTerminalConverterRecord : ebas

      MultiTerminalConverterRecord : ib

      MultiTerminalConverterRecord : marg

      MultiTerminalConverterRecord : n

      MultiTerminalConverterRecord : rc

      MultiTerminalConverterRecord : setvl

      MultiTerminalConverterRecord : tap

      MultiTerminalConverterRecord : tpmn

      MultiTerminalConverterRecord : tpmx

      MultiTerminalConverterRecord : tr

      MultiTerminalConverterRecord : tstp

      MultiTerminalConverterRecord : xc

Slots

Name Cardinality and Range Description Inheritance
ib 1
Integer
IB - AC converter bus number direct
n 1
Integer
N - Number of bridges in series direct
angmx 1
Float
ANGMX - Nominal maximum ALPHA or GAMMA firing angle in degrees direct
angmn 1
Float
ANGMN - Minimum steady-state ALPHA or GAMMA firing angle in degrees direct
rc 1
Float
RC - Commutating resistance per bridge in ohms direct
xc 1
Float
XC - Commutating reactance per bridge in ohms direct
ebas 1
Float
EBAS - Primary base AC voltage in kV direct
tr 0..1
Float
TR - Actual transformer ratio (pu) direct
tap 0..1
Float
TAP - Tap setting direct
tpmx 0..1
Float
TPMX - Maximum tap setting direct
tpmn 0..1
Float
TPMN - Minimum tap setting direct
tstp 0..1
Float
TSTP - Tap step (must be positive) direct
setvl 1
Float
SETVL - Converter setpoint; DC voltage in kV for the converters at VCONV/VCON... direct
dcpf 0..1
Float
DCPF - Converter participation factor for sharing order reductions on the sam... direct
marg 0..1
Float
MARG - Rectifier margin as per-unit fraction of desired DC power or current (... direct
cnvcod 0..1
Integer
CNVCOD - Converter code (zero or positive for positive pole, negative for neg... direct

Usages

used by used in type used
RawModel multi_terminal_converter_records range MultiTerminalConverterRecord

Identifier and Mapping Information

Schema Source

  • from schema: https://gridappsd.org/cimhub/raw_v34

Mappings

Mapping Type Mapped Value
self raw:MultiTerminalConverterRecord
native raw:MultiTerminalConverterRecord

LinkML Source

Direct

name: MultiTerminalConverterRecord
description: 'Converter station record of a multi-terminal DC line (NCONV per line).

  '
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
  ib:
    name: ib
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: int
    description: IB - AC converter bus number
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    - MultiTerminalDCBusRecord
    range: integer
    required: true
  n:
    name: n
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: int
    description: N - Number of bridges in series
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: integer
    required: true
  angmx:
    name: angmx
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: ANGMX - Nominal maximum ALPHA or GAMMA firing angle in degrees
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: deg
  angmn:
    name: angmn
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: ANGMN - Minimum steady-state ALPHA or GAMMA firing angle in degrees
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: deg
  rc:
    name: rc
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 5
    description: RC - Commutating resistance per bridge in ohms
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: ohm
  xc:
    name: xc
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 5
    description: XC - Commutating reactance per bridge in ohms
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: ohm
  ebas:
    name: ebas
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: EBAS - Primary base AC voltage in kV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: kV
  tr:
    name: tr
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: TR - Actual transformer ratio (pu)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  tap:
    name: tap
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: TAP - Tap setting
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  tpmx:
    name: tpmx
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.5
    description: TPMX - Maximum tap setting
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  tpmn:
    name: tpmn
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.51
    description: TPMN - Minimum tap setting
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  tstp:
    name: tstp
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 5
      raw_default:
        tag: raw_default
        value: 0.00625
    description: TSTP - Tap step (must be positive)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  setvl:
    name: setvl
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: SETVL - Converter setpoint; DC voltage in kV for the converters at
      VCONV/VCONVN, otherwise current in A (+ rectifier, - inverter) or power in MW
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    domain_of:
    - TwoTerminalDCRecord
    - MultiTerminalConverterRecord
    range: float
    required: true
  dcpf:
    name: dcpf
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: DCPF - Converter participation factor for sharing order reductions
      on the same pole
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  marg:
    name: marg
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: MARG - Rectifier margin as per-unit fraction of desired DC power
      or current (rectifiers only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  cnvcod:
    name: cnvcod
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: CNVCOD - Converter code (zero or positive for positive pole, negative
      for negative pole)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    domain_of:
    - MultiTerminalConverterRecord
    range: integer
    required: false

Induced

name: MultiTerminalConverterRecord
description: 'Converter station record of a multi-terminal DC line (NCONV per line).

  '
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
  ib:
    name: ib
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: int
    description: IB - AC converter bus number
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    - MultiTerminalDCBusRecord
    range: integer
    required: true
  n:
    name: n
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: int
    description: N - Number of bridges in series
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: integer
    required: true
  angmx:
    name: angmx
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: ANGMX - Nominal maximum ALPHA or GAMMA firing angle in degrees
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: deg
  angmn:
    name: angmn
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: ANGMN - Minimum steady-state ALPHA or GAMMA firing angle in degrees
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: deg
  rc:
    name: rc
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 5
    description: RC - Commutating resistance per bridge in ohms
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: ohm
  xc:
    name: xc
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 5
    description: XC - Commutating reactance per bridge in ohms
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: ohm
  ebas:
    name: ebas
    annotations:
      order:
        tag: order
        value: 7
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: EBAS - Primary base AC voltage in kV
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: true
    unit:
      ucum_code: kV
  tr:
    name: tr
    annotations:
      order:
        tag: order
        value: 8
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: TR - Actual transformer ratio (pu)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  tap:
    name: tap
    annotations:
      order:
        tag: order
        value: 9
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: TAP - Tap setting
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  tpmx:
    name: tpmx
    annotations:
      order:
        tag: order
        value: 10
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.5
    description: TPMX - Maximum tap setting
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  tpmn:
    name: tpmn
    annotations:
      order:
        tag: order
        value: 11
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.51
    description: TPMN - Minimum tap setting
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  tstp:
    name: tstp
    annotations:
      order:
        tag: order
        value: 12
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 5
      raw_default:
        tag: raw_default
        value: 0.00625
    description: TSTP - Tap step (must be positive)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  setvl:
    name: setvl
    annotations:
      order:
        tag: order
        value: 13
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
    description: SETVL - Converter setpoint; DC voltage in kV for the converters at
      VCONV/VCONVN, otherwise current in A (+ rectifier, - inverter) or power in MW
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    owner: MultiTerminalConverterRecord
    domain_of:
    - TwoTerminalDCRecord
    - MultiTerminalConverterRecord
    range: float
    required: true
  dcpf:
    name: dcpf
    annotations:
      order:
        tag: order
        value: 14
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 1.0
    description: DCPF - Converter participation factor for sharing order reductions
      on the same pole
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  marg:
    name: marg
    annotations:
      order:
        tag: order
        value: 15
      value_type:
        tag: value_type
        value: float
      precision:
        tag: precision
        value: 4
      raw_default:
        tag: raw_default
        value: 0.0
    description: MARG - Rectifier margin as per-unit fraction of desired DC power
      or current (rectifiers only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: float
    required: false
  cnvcod:
    name: cnvcod
    annotations:
      order:
        tag: order
        value: 16
      value_type:
        tag: value_type
        value: int
      raw_default:
        tag: raw_default
        value: 1
    description: CNVCOD - Converter code (zero or positive for positive pole, negative
      for negative pole)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/multi_terminal_dc
    rank: 1000
    owner: MultiTerminalConverterRecord
    domain_of:
    - MultiTerminalConverterRecord
    range: integer
    required: false