Skip to content

Class: EquipmentTerminalRecord

Equipment terminal record connecting a piece of equipment to a substation node. One record shape covers every equipment form; TYP selects the form and tells which optional fields are used (J/K for branches and transformers, identifier for the equipment ID, CKT or NAME).

URI: raw:EquipmentTerminalRecord

 classDiagram
    class EquipmentTerminalRecord
    click EquipmentTerminalRecord href "../EquipmentTerminalRecord/"
      EquipmentTerminalRecord : bus_number

      EquipmentTerminalRecord : identifier

      EquipmentTerminalRecord : j_bus

      EquipmentTerminalRecord : k_bus

      EquipmentTerminalRecord : node_number

      EquipmentTerminalRecord : substation_number

      EquipmentTerminalRecord : terminal_type

Slots

Name Cardinality and Range Description Inheritance
bus_number 1
Integer
I - Bus number or extended bus name of the equipment's bus (From bus for bran... direct
node_number 1
Integer
NI - Node number (1 through 999) inside the substation direct
terminal_type 1
String
TYP - Equipment form code (L load, F fixed shunt, M machine, B or 2 branch or... direct
j_bus 0..1
Integer
J - To bus number or extended bus name (branch and transformer forms only) direct
k_bus 0..1
Integer
K - Third bus number or extended bus name (three-winding transformer form onl... direct
identifier 0..1
String
ID, CKT or NAME - Equipment identifier for L, F, M, I, B, 2 and 3 forms; equi... direct
substation_number 0..1
Integer
IS - Substation number of the enclosing substation block (filled by the reade... direct

Usages

used by used in type used
RawModel equipment_terminal_records range EquipmentTerminalRecord

Identifier and Mapping Information

Schema Source

  • from schema: https://gridappsd.org/cimhub/raw_v34

Mappings

Mapping Type Mapped Value
self raw:EquipmentTerminalRecord
native raw:EquipmentTerminalRecord

LinkML Source

Direct

name: EquipmentTerminalRecord
description: Equipment terminal record connecting a piece of equipment to a substation
  node. One record shape covers every equipment form; TYP selects the form and tells
  which optional fields are used (J/K for branches and transformers, identifier for
  the equipment ID, CKT or NAME).
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
  bus_number:
    name: bus_number
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: int
    description: I - Bus number or extended bus name of the equipment's bus (From
      bus for branches)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    domain_of:
    - BusRecord
    - LoadRecord
    - FixedShuntRecord
    - GeneratorRecord
    - AreaInterchangeRecord
    - SwitchedShuntRecord
    - SubstationNodeRecord
    - EquipmentTerminalRecord
    range: integer
    required: true
  node_number:
    name: node_number
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: int
    description: NI - Node number (1 through 999) inside the substation
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    domain_of:
    - SubstationNodeRecord
    - EquipmentTerminalRecord
    range: integer
    required: true
  terminal_type:
    name: terminal_type
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      quote:
        tag: quote
        value: true
      quote_char:
        tag: quote_char
        value: ''''
    description: TYP - Equipment form code (L load, F fixed shunt, M machine, B or
      2 branch or two-winding transformer, 3 three-winding transformer, S switched
      shunt, I induction machine, D two-terminal DC, V VSC DC, N multi-terminal DC,
      A FACTS)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    rank: 1000
    domain_of:
    - EquipmentTerminalRecord
    range: string
    required: true
  j_bus:
    name: j_bus
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: int
    description: J - To bus number or extended bus name (branch and transformer forms
      only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    rank: 1000
    domain_of:
    - EquipmentTerminalRecord
    range: integer
    required: false
  k_bus:
    name: k_bus
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: int
    description: K - Third bus number or extended bus name (three-winding transformer
      form only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    rank: 1000
    domain_of:
    - EquipmentTerminalRecord
    range: integer
    required: false
  identifier:
    name: identifier
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: string
      quote:
        tag: quote
        value: true
      quote_char:
        tag: quote_char
        value: ''''
      raw_default_rule:
        tag: raw_default_rule
        value: '''1'' for L, F, M, I, B, 2 and 3 forms; no default for D, V, N and
          A'
    description: ID, CKT or NAME - Equipment identifier for L, F, M, I, B, 2 and 3
      forms; equipment name for D, V, N and A forms; absent for S
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    rank: 1000
    domain_of:
    - EquipmentTerminalRecord
    range: string
    required: false
  substation_number:
    name: substation_number
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: int
      structural:
        tag: structural
        value: true
    description: IS - Substation number of the enclosing substation block (filled
      by the reader)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    domain_of:
    - SubstationRecord
    - SubstationNodeRecord
    - StationSwitchingDeviceRecord
    - EquipmentTerminalRecord
    range: integer
    required: false

Induced

name: EquipmentTerminalRecord
description: Equipment terminal record connecting a piece of equipment to a substation
  node. One record shape covers every equipment form; TYP selects the form and tells
  which optional fields are used (J/K for branches and transformers, identifier for
  the equipment ID, CKT or NAME).
from_schema: https://gridappsd.org/cimhub/raw_v34
attributes:
  bus_number:
    name: bus_number
    annotations:
      order:
        tag: order
        value: 1
      value_type:
        tag: value_type
        value: int
    description: I - Bus number or extended bus name of the equipment's bus (From
      bus for branches)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    owner: EquipmentTerminalRecord
    domain_of:
    - BusRecord
    - LoadRecord
    - FixedShuntRecord
    - GeneratorRecord
    - AreaInterchangeRecord
    - SwitchedShuntRecord
    - SubstationNodeRecord
    - EquipmentTerminalRecord
    range: integer
    required: true
  node_number:
    name: node_number
    annotations:
      order:
        tag: order
        value: 2
      value_type:
        tag: value_type
        value: int
    description: NI - Node number (1 through 999) inside the substation
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    owner: EquipmentTerminalRecord
    domain_of:
    - SubstationNodeRecord
    - EquipmentTerminalRecord
    range: integer
    required: true
  terminal_type:
    name: terminal_type
    annotations:
      order:
        tag: order
        value: 3
      value_type:
        tag: value_type
        value: string
      quote:
        tag: quote
        value: true
      quote_char:
        tag: quote_char
        value: ''''
    description: TYP - Equipment form code (L load, F fixed shunt, M machine, B or
      2 branch or two-winding transformer, 3 three-winding transformer, S switched
      shunt, I induction machine, D two-terminal DC, V VSC DC, N multi-terminal DC,
      A FACTS)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    rank: 1000
    owner: EquipmentTerminalRecord
    domain_of:
    - EquipmentTerminalRecord
    range: string
    required: true
  j_bus:
    name: j_bus
    annotations:
      order:
        tag: order
        value: 4
      value_type:
        tag: value_type
        value: int
    description: J - To bus number or extended bus name (branch and transformer forms
      only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    rank: 1000
    owner: EquipmentTerminalRecord
    domain_of:
    - EquipmentTerminalRecord
    range: integer
    required: false
  k_bus:
    name: k_bus
    annotations:
      order:
        tag: order
        value: 5
      value_type:
        tag: value_type
        value: int
    description: K - Third bus number or extended bus name (three-winding transformer
      form only)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    rank: 1000
    owner: EquipmentTerminalRecord
    domain_of:
    - EquipmentTerminalRecord
    range: integer
    required: false
  identifier:
    name: identifier
    annotations:
      order:
        tag: order
        value: 6
      value_type:
        tag: value_type
        value: string
      quote:
        tag: quote
        value: true
      quote_char:
        tag: quote_char
        value: ''''
      raw_default_rule:
        tag: raw_default_rule
        value: '''1'' for L, F, M, I, B, 2 and 3 forms; no default for D, V, N and
          A'
    description: ID, CKT or NAME - Equipment identifier for L, F, M, I, B, 2 and 3
      forms; equipment name for D, V, N and A forms; absent for S
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    rank: 1000
    owner: EquipmentTerminalRecord
    domain_of:
    - EquipmentTerminalRecord
    range: string
    required: false
  substation_number:
    name: substation_number
    annotations:
      order:
        tag: order
        value: 0
      value_type:
        tag: value_type
        value: int
      structural:
        tag: structural
        value: true
    description: IS - Substation number of the enclosing substation block (filled
      by the reader)
    from_schema: https://gridappsd.org/cimhub/raw_v34/classes/substation
    owner: EquipmentTerminalRecord
    domain_of:
    - SubstationRecord
    - SubstationNodeRecord
    - StationSwitchingDeviceRecord
    - EquipmentTerminalRecord
    range: integer
    required: false